Z2FS 6, 16, 22 Modular Throttle Check Valve
Z2FS 6, 16, 22 Modular Throttle Check Valve
Z2FS 6, 16, 22 Modular Throttle Check Valve
Features:
- Sandwich plate design
- Porting pattern to DIN 24 340, from A,ISO 4401
and CETOP-RP 121H
- Limiting of main or pilot flow with two service ports,
- Meter-in or meter-out control.
Functional , Section
Valves type Z 2 FS are double throttle/check valves in sandwich plate design.They are used to limit main or pilot
oil flow at one or two service ports.Two symmetrically arranged throttle/check valves limit flow (by means of
adjustable throttle spools) in one direction and permit free return flow in the other direction.
Main flow limiting
The double throttle/check valve is fitted between the directional valve and the subplate to change the speed of an
actuator (main flow limiting).
Pilot flow limiting
In the case of pilot operated directional valves, the double throttle/check valve may be used as a pilot choke
adjustment (pilot flow limiting). In this case, it is fitted between the main valve and the pilot valve.
P HUADE HYDRAULICS
Principle of Hydraulic systems
Ordering details
Z2FS -30 B / *
Technical data (for applications outside these parameters, please consult us!)
Size 6 16 22
Pressure fluid Mineral oil (for NBR seal) or Phospate ester (for FPM seal)
2
Viscosity range (mm /s) 10 to 800
HUADE HYDRAULICS Q
Characteristic curves (measured at v = 41 mm2/s and t = 50
Pressure difference p in relationship to the flow qV via the check valve (throttle closed)
Z2FS6 Z2FS16
Pressure difference
Pressure difference
in MPa
in MPa
Flow in L/min Flow in L/min
Z2FS22
Pressure difference
in MPa
Flow in L/min
Z2FS6 Z2FS16
Pressure difference in MPa
R HUADE HYDRAULICS
Characteristic curves (measured at v = 41 mm2/s and t = 50
Type Z2FS6:
1 Name plate
2 Setting screw for alteration of flow cross section
3 Turn anti-clockwise = increases flow
turn clockwise = decreases flow
4 Valve fixing holes
5 Ports A, B, P, T
6 O-ring plate
7 To change from meter-in to meter-out,rotate the
unit about the "X"-"X" axis
HUADE HYDRAULICS S
Unit dimensions (Dimensions in mm)
Type Z2FS16:
~ééêçñK=ã~ñ=OVQ
~ééêçñK=ã~ñ=OQS
Type Z2FS22
~ééêçñK=ã~ñ=POM
~ééêçñK=ã~ñ=OSU
1 Name plate
2 Setting screw for alteration of flow cross
section
3 Turn anti-clockwise = increases flow
turn clockwise = decreases flow
4 2 two locating pins
5 2 two locating pins holes
6 6 Valve fixing holes
7 O-ring for ports A, B, P, T
8 O-ring for ports X, Y, L
T HUADE HYDRAULICS
Notice
1. The fluid must be filtered. Minimum filter fineness is 20 µm.
2. The tank must be sealed up and an air breather/filter must be installed on air suction/entrance.
3. Subplate are not supplied, if required, please ordering separetly.
4. Valve fixing bolts/screws must be high tensilel (class 10.9). Please select and consult manufacturer.