Double throttle/check valve,

BEIJING HUADE RE:27505/12.2004


Type Z2FS Series 30
HYDRAULIC INDUSTRIAL
GROUP CO.,LTD. Replaces
Sizes 61622 up to 31.5MPa up to 350 L/min
RE27505/5.2001

Features:
- Sandwich plate design
- Porting pattern to DIN 24 340, from A,ISO 4401
and CETOP-RP 121H
- Limiting of main or pilot flow with two service ports,
- Meter-in or meter-out control.

Functional , Section

Valves type Z 2 FS are double throttle/check valves in sandwich plate design.They are used to limit main or pilot
oil flow at one or two service ports.Two symmetrically arranged throttle/check valves limit flow (by means of
adjustable throttle spools) in one direction and permit free return flow in the other direction.
Main flow limiting
The double throttle/check valve is fitted between the directional valve and the subplate to change the speed of an
actuator (main flow limiting).
Pilot flow limiting
In the case of pilot operated directional valves, the double throttle/check valve may be used as a pilot choke
adjustment (pilot flow limiting). In this case, it is fitted between the main valve and the pilot valve.

Double throttle/check valve, Type Z2FS6

A Meter-out control A Meter-in control


Meter-in control S Meter-out control S2
B Meter-in control:S3 B Meter-out control:S4

 P HUADE HYDRAULICS
Principle of Hydraulic systems

Meter-out control on port A Meter-in control on port A


Meter-in control S Meter-out control S2
Meter-in control:S3 on potr B Meter-out control:S on port B

Ordering details

Z2FS -30 B / *

Double throttle/check valve Further details in clear text

Nominal size 6 =6 No code= Mineral oil


Nominal size 16 = 16 V= Phospate ester
Nominal size 22 = 22
No code = (With two throttle/check valves)
Series 30 to 39 =30 S = Meter-in
(30 to 39: unchanged installation and connection dimensions) S2 = Meter-out
S3 = Meter-out on port A, meter-in on port B
Technology of Beijing Huade Hydraulic =B S4 = Meter-in on port A, meter-out on port B

Technical data (for applications outside these parameters, please consult us!)

Size 6 16 22

Maximum flow (L/min) 80 250 350

Maximum working pressure (MPa) 31.5 35

Pressure fluid Mineral oil (for NBR seal) or Phospate ester (for FPM seal)

2
Viscosity range (mm /s) 10 to 800

Fluid temperature range () -30 to +80

HUADE HYDRAULICS  Q
Characteristic curves (measured at v = 41 mm2/s and t = 50 

Pressure difference  p in relationship to the flow qV via the check valve (throttle closed)

Z2FS6 Z2FS16
Pressure difference

Pressure difference
in MPa

in MPa
Flow in L/min  Flow in L/min 

Z2FS22
Pressure difference
in MPa

Flow in L/min 

Pressure difference  p in relationship to the flow qV at a constant throttle setting.

Z2FS6 Z2FS16
Pressure difference in MPa

Pressure difference in MPa


Throttle setting in turns

Throttle setting in turns

Flow in L/min  Flow in L/min 

 R HUADE HYDRAULICS
Characteristic curves (measured at v = 41 mm2/s and t = 50 

Pressure difference  p in relation to the flow qV at constant throttle setting


Z2FS22

Pressure difference in MPa 

Throttle setting in turns


Flow in L/min 

Unit dimensions (Dimensions in mm)

Type Z2FS6:

1 Name plate
2 Setting screw for alteration of flow cross section
3 Turn anti-clockwise = increases flow
turn clockwise = decreases flow
4 Valve fixing holes
5 Ports A, B, P, T
6 O-ring plate
7 To change from meter-in to meter-out,rotate the
unit about the "X"-"X" axis

HUADE HYDRAULICS  S
Unit dimensions (Dimensions in mm)

Type Z2FS16:

~ééêçñK=ã~ñ=OVQ
~ééêçñK=ã~ñ=OQS

Type Z2FS22

~ééêçñK=ã~ñ=POM

~ééêçñK=ã~ñ=OSU

1 Name plate
2 Setting screw for alteration of flow cross
section
3 Turn anti-clockwise = increases flow
turn clockwise = decreases flow
4 2 two locating pins
5 2 two locating pins holes
6 6 Valve fixing holes
7 O-ring for ports A, B, P, T
8 O-ring for ports X, Y, L

 T HUADE HYDRAULICS
Notice
1. The fluid must be filtered. Minimum filter fineness is 20 µm.

2. The tank must be sealed up and an air breather/filter must be installed on air suction/entrance.
3. Subplate are not supplied, if required, please ordering separetly.

4. Valve fixing bolts/screws must be high tensilel (class 10.9). Please select and consult manufacturer.

according to the parameter listed in the datasheet.


5. Roughness of surface mating with the valve is required to .

6. Surface straightness of mating piece is required to 0.01/100mm.

All rights reserved-Subject to revision


_______________________________________________________

THM Huade Hydraulics (P) Ltd


F-127, Focal Point, Phase VIII
Ludhaiana-141010, India
Phone: 0091+161+2672777, Fax: 0091+161+2672778