Breaker & Switchgear System
Appearance
Rated current In (A) 3, 5, 10, 15, 3, 5, 10, 15, 10, 15, 20, 30, 10, 15, 20, 25, 30, 10, 15, 20, 25, 30, 10, 15, 20, 30,
at ambient temp. 40℃ 20, 30. 20, 30. 40, 50. 40, 50, 60. 40, 50, 60. 40, 50, 60.
ELCB c 52 68 68 68 68 68
ca 67 90 90 90 90 90
Weight (kg) 0.3 0.4 0.45 0.65 0.45 0.65 0.45 0.65 0.85 0.45 0.65 0.85 1.3
250V — — — — — —
DC
SPD 125V — — — — — —
Connection Clamp terminal Clamp terminal Clamp terminal Clamp terminal Clamp terminal Clamp terminal
Trip Unit Hydraulic magnetic Hydraulic magnetic Hydraulic magnetic Hydraulic magnetic Hydraulic magnetic Hydraulic magnetic
Note 1. "●" which can be installed by client, "○" which have to be installed by manufacturer. "—" which is not available.
Above accessories table is for 3P breaker.
2. Ics= 50% Icu
3. Adjustable thermal: 80%~100% In.
BO
02
Breaker & Switchgear System
80% ~ 100% Adj. (A)
100
15, 20, 30, 40, 50 10, 15, 20, 30, 40, 10, 15, 20, 30, 40, 10, 15, 20, 30, 40, 15, 20, 30, 40, 50,
40, 50, 63, 80, 100.
60, 75, 100. 50, 60, 75, 100. 50, 60, 75, 100. 50, 60, 75, 100. 60, 75, 100.
1 2 3 2 3 2 3 4 3 4 3 4
— — 250 — — — — Index
25.4 50 75 50 75 60 90 120 105 140 105 140
91 90 90 90 92 112
0.29 0.45 0.65 0.45 0.65 0.9 1.3 1.6 1.5 1.9 2.1 2.6
— 5 5 15 20 25
ACB
5 7.5 10 25 32 42
5 10 15 30 36 50
MCB
25 15 25 50 85 85
— — 10 — — — —
— — 15 — — — — SPD
Clamp terminal Clamp terminal Clamp terminal Clamp terminal Clamp terminal Clamp terminal
— ○ ○ ○ ● ○
MS
— ○ ○ ○ ● ○
— ○ ○ ○ ● ○
— ○ ○ ○ ● — MMS
— ● ● ● ● ●
— ● ● ● ● ●
Adj. thermal
Thermal magnetic Hydraulic magnetic Hydraulic magnetic Hydraulic magnetic Thermal magnetic
Fixed magnetic
BO
03
Breaker & Switchgear System
Appearance
Rated current In (A) 10, 15, 20, 30, 40, 10, 15, 20, 30, 40,
40, 50, 63, 80, 100. 40, 50, 63, 80, 100. 125, 140, 160.
at ambient temp. 40℃ 50, 60, 75, 100, 125. 50, 60, 75, 100, 125.
ELCB c 86 86 68 68 68
ca 112 112 90 90 92
250V — — — — —
DC
SPD 125V — — — — —
Connection Clamp terminal Clamp terminal Clamp terminal Clamp terminal Clamp terminal
Adj. thermal
Trip Unit Thermal magnetic Thermal magnetic Hydraulic magnetic Hydraulic magnetic
Fixed magnetic
Note 1. "●" which can be installed by client, "○" which have to be installed by manufacturer. "—" which is not available.
Above accessories table is for 3P breaker.
2. Ics= 50% Icu
3. Adjustable thermal: 80%~100% In.
BO
04
Breaker & Switchgear System
80% ~ 100% Adj. (A) 80% ~ 100% Adj. (A)
160 250
3 4 3 4 3 4 3 4 2 3 4 3 4
— — — — 250 — — — Index
105 140 105 140 105 140 105 140 105 105 140 105 140
1.5 1.9 2.1 2.6 2.1 2.6 2.1 2.6 1.3 1.5 1.9 1.5 1.9
20 25 42 50 7.5 15
ACB
32 42 55 70 15 25
36 50 70 85 22 30
MCB
85 85 100 125 30 50
— — — — 10 — — —
— — — — 15 — — — SPD
Clamp terminal Clamp terminal Clamp terminal Clamp terminal Clamp terminal Clamp terminal
● ○ ○ ○ ● ●
MS
● ○ ○ ○ ● ●
● ○ ○ ○ ● ●
● — — — ● ● MMS
● ● ● ● ● ●
● ● ● ● ● ●
BO
05
Molded Case Circuit Breaker
Breaker & Switchgear System
Appearance
a 105 140 105 140 105 140 105 140 140 140 185
ELCB c 68 86 86 86 103
Weight (kg) 1.5 1.9 2.1 2.6 2.1 2.6 2.1 2.6 5.0 5.7 7.5
ACB 500V 20 25 42 50 14
Rated breaking capacity (kA)
250V — — — — 10 — —
DC
SPD 125V — — — — 15 — —
Connection Clamp terminal Clamp terminal Clamp terminal Clamp terminal Busbar
Adj. thermal
Trip Unit Fixed magnetic
Thermal magnetic Thermal magnetic Thermal magnetic Thermal magnetic
Note 1. "●" which can be installed by client, "○" which have to be installed by manufacturer. "—" which is not available.
Above accessories table is for 3P breaker.
2. Ics= 50% Icu
3. Adjustable thermal: 80%~100% In.
BO
06
Breaker & Switchgear System
400 630
250, 300, 350, 400. 250, 300, 350, 400. 250, 300, 350, 400. 250, 300, 350, 400. 500, 600, 630. 500, 630.
3 4 3 4 3 4 3 4 3 3 4
20 25 42 65 14 20
ACB
30 42 55 85 22 30
35 50 70 85 25 35
MCB
50 85 100 125 35 50
— — — — 10 20 —
— — — — — — SPD
● ● ● ● ● ●
MS
● ● ● ● ● ●
● ● ● ● ● ●
● ● ● ● ● ● MMS
● ● ● ● ● ●
● ● ● ● ● ●
BO
07
Breaker & Switchgear System
Appearance
a 210 280 210 280 210 280 210 280 210 280
ACB 500V 25 42 65 20 25
Rated breaking capacity (kA)
250V 40 — — — 20 — 40 —
DC
SPD 125V — — — — —
Fixed thermal Fixed thermal Fixed thermal Fixed thermal Fixed thermal
Trip Unit Adj. magnetic Adj. magnetic Adj. magnetic Adj. magnetic Adj. magnetic
Note 1 "●" which can be installed by client, "○" which have to be installed by manufacturer. "—" which is not available.
Above accessories table is for 3P breaker.
2. Ics= 50% Icu
BO
08
Breaker & Switchgear System
800 1000 1200 1600
3 4 3 4 3 3 3
— — — — — Index
210 280 210 280 210 210 210
42 65 65 65 65
ACB
70 85 85 85 85
— — — — —
— — — — — SPD
● ● ○ ○ ○
MS
● ● ○ ○ ○
● ● ○ ○ ○
● ● ○ ○ ○ MMS
● ● — — —
● ● — — —
Fixed thermal Fixed thermal Fixed thermal Fixed thermal Fixed thermal
Adj. magnetic Adj. magnetic Adj. magnetic Adj. magnetic Adj. magnetic
BO
09
Breaker & Switchgear System
Model BMA125-STA BMA125-LTA BMA125-HTA BMA160-STA BMA160-LTA BMA160-HTA BMA250-STA BMA250-LTA BMA250-HTA
Appearance
Rated current In (A) 15, 16, 20, 25, 30, 32, 40, 50, 60, 40, 50, 60, 63, 70, 75, 80, 100,
175, 200, 225, 250A
at ambient temp. 40℃ 63, 75, 80, 100, 125A 125, 140, 150, 160A
Rated insulation
AC 800 800 800
voltage Ui (V)
MCCB c 68 68 68 68 68 68
ELCB
ca 92 92 92 92 92 92
ACB
Rated breaking capacity (kA)
500V 18 kA 22 kA 30 kA 20 kA 22 kA 30 kA 20 kA 22 kA 30 kA
Tripping button Equipped Equipped Equipped Equipped Equipped Equipped Equipped Equipped Equipped
Note 1. Isc=100%Icu
BO
10
Breaker & Switchgear System
400 630 800 630 800
BMA400-LTA BMA400-HTA BMA400-RTA BMA630-HTA BMA630-RTA BMA800-HTA BMA800-RTA BMA630-HED BMA630-RED BMA800-HED BMA800-RED
250, 300, 350, 400A 500, 600, 630A 700, 800A 630A 800A
3 4 3 4 3 4 3 4 3 4
140 185 210 280 210 280 210 280 210 280 Index
257 257 275 275 275 275 275 275 275 275
103 103 103 103 103 103 103 103 103 103 MCCB
ELCB
155 155 155 155 155 155 155 155 155 155
194 194 243 243 243 243 243 243 243 243
ATS
44 44 70 70 70 70 70 70 70 70
ACB
22 kA 30 kA 50 kA 30 kA 50 kA 30 kA 50 kA 30 kA 50 kA 30 kA 50 kA
30 kA 42 kA 65 kA 42 kA 65 kA 42 kA 65 kA 42 kA 65 kA 42 kA 65 kA
MCB
36 kA 50 kA 70 kA 50 kA 70 kA 50 kA 70 kA 50 kA 70 kA 50 kA 70 kA
● ● ● ● ● ● ● ● ● ● ●
MS
● ● ● ● ● ● ● ● ● ● ●
● ● ● ● ● ● ● ● ● ● ●
MMS
● ● ● ● ● ● ● ● ● ● ●
● ● ● ● ● ● ● ● ● ● ●
● ● ● ● ● ● ● ● ● ● ●
Equipped Equipped Equipped Equipped Equipped Equipped Equipped Equipped Equipped Equipped Equipped
BO
11
Breaker & Switchgear System
Type BM100-HE BM100-RE BM100-UE BM160-HE BM160-RE BM160-UE BM250-HE BM250-RE BM250-UE
Electronically adjustable 40, 45, 50, 60, 70, 64, 72, 80, 96, 112, 100, 113, 125, 150, 175,
current Ir (A) 80, 90, 95, 100. 128, 144, 152, 160. 200, 225, 238, 250.
Model HE RE UE HE RE UE HE RE UE
ELCB c 86 86 86
ATS (mm)
bb 126 126 126
aa 35 35 35
Communication (COM) ○ ○ ○
Communication (HUB) ○ ○ ○
BO
12
Breaker & Switchgear System
400 630 800 1000 1250
BM400-HE BM400-RE BM400-UE BM630-HE BM630-RE BM630-UE BM800-SE BM800-HE BM800-RE BM1000-SE BM1000-HE BM1250-SE BM1250-HE
160, 180, 200, 240, 280, 252, 284, 315, 378, 441, 320, 360, 400, 480, 560, 400, 450, 500, 600, 700, 500, 563, 625, 750, 875,
320, 360, 380, 400. 504, 567, 600, 630. 640, 720, 760, 800. 800, 900, 950, 1000. 1000, 1125, 1188, 1250.
3P / 4P 3P / 4P 3P / 4P 3P 3P
HE RE UE HE RE UE SE HE RE SE HE SE HE
50 70 85 50 70 85 50 70 85 70 85 70 85
Index
140 / 185 210 / 280 210 / 280 210 210
44 70 70 70 70
○ ○ ○ ─ ─
○ ○ ○ ─ ─
MS
○ ○ ○ ─ ─
○ ○ ○ ─ ─ MMS
─ ─ ─ ─ ─
○ ○ ○ ─ ─
○ ○ ○ ─ ─
○ ○ ○ ─ ─
BO
13
Breaker & Switchgear System
Appearance
Rated current In (A) 15, 20, 30, 40, 50, 15, 20, 30, 40, 50,
15, 20, 30, 40, 50.
at ambient temp. 40℃ 60, 75, 100. 60, 75, 100.
Index Rated voltage (VAC) 230, 400. 230, 400. 230, 400.
30, 100, 300, 500 30, 100, 300, 500 30, 100, 300, 500
Rated current sensitivity l△n (mA)
speed
High
2l△n max. non-operating time (S) 0, 0.2, 0.4, 1.0 0, 0.2, 0.4, 1.0 0, 0.2, 0.4, 1.0
ATS
Leakage detection mode Mechanical push-button Mechanical push-button Mechanical push-button
c 68 68 68
ca 90 90 90
SPD EN 60947-2
Rated
Note 1. "●" which can be installed by client, "○" which have to be installed by manufacturer. "—" which is not available.
2. Specify rated current sensitivity when place the order.
3. Ics= 50% Icu
4. Adjustable thermal: 80%~100% In.
5. Specify, when order delay type rated current sensitivity 30-100-500mA.
BO
14
Breaker & Switchgear System
80% ~ 100% Adj. (A)
125, 140, 160. 175, 200, 225, 250. 250, 300, 350, 400. 250, 300, 350, 400. 250, 300, 350, 400.
3 4 3 4 3 4 3 4 3 4
230, 400. 230, 400. 230, 400. 230, 400. 230, 400. Index
30, 30- 100- 500 30- 100- 500 30- 100- 500 30- 100- 500
100-300-500 Adj. adjustable adjustable adjustable adjustable
0, 0.2, 0.4, 1.0 0, 0.2, 0.4, 1.0 0, 0.2, 0.4, 1.0 0, 0.2, 0.4, 1.0 0.1, 0.5, 1.0
ATS
Mechanical push-button Mechanical push-button Mechanical push-button Mechanical push-button Mechanical push-button
105 140 105 140 140 185 140 185 140 185
1.7 2.3 1.7 2.3 6.6 8.4 6.6 8.4 5.7 7.5
25 25 30 42 55
SPD
30 30 35 50 70
50 50 50 85 100
● ● ● ● ●
MS
● ● ● ● ●
● ● ● ● ●
● ● ● ● ● MMS
● ● ● ● ●
● ● ● ● ●
○ ○ ○ ○ ○
Adj. thermal Fixed magnetic Adj. thermal Fixed magnetic Thermal magnetic Thermal magnetic Thermal magnetic
BO
15
Breaker & Switchgear System
Appearance
Index Rated voltage (VAC) 230, 400. 230, 400. 230, 400.
2l△n max. non-operating time (S) 0.1, 0.5, 1.0 0.1, 0.5, 1.0 0.1, 0.5, 1.0
ATS
Leakage detection mode Mechanical push-button Mechanical push-button Mechanical push-button
SPD EN 60947-2
Rated
Trip Unit Thermal magnetic Fixed thermal Adj. magnetic Fixed thermal Adj. magnetic
Note 1. "●" which can be installed by client, "○" which have to be installed by manufacturer. "—" which is not available.
2. Specify rated current sensitivity when place the order.
3. Ics= 50% Icu
4. Adjustable thermal: 80%~100% In.
5. Specify, when order delay type rated current sensitivity 30-100-500mA.
BO
16
Breaker & Switchgear System
630 800
3 4 3 4 3 4 3 4
0.1, 0.5, 1.0 0.1, 0.5, 1.0 0.1, 0.5, 1.0 0.1, 0.5, 1.0
ATS
Mechanical push-button Mechanical push-button Mechanical push-button Mechanical push-button
85 50 70 85
SPD
100 50 70 100
● ● ● ●
MS
● ● ● ●
● ● ● ●
● ● ● ● MMS
● ● ● ●
● ● ● ●
○ ○ ○ ○
Fixed thermal Adj. magnetic Fixed thermal Adj. magnetic Fixed thermal Adj. magnetic Fixed thermal Adj. magnetic
BO
17
Molded Case Circuit Breaker
Breaker & Switchgear System
Bolt on type
Appearance
Rated Voltage (A.C) #1 110 220* 220 110 220* 220 110/220* 380 110/220* 220
a 25 50 75 25 50 75 25 50 75 25 50 75
b 95 95 95 95
Dimensions
Weight (kg) 0.15 0.31 0.46 0.2 0.4 0.6 0.22 0.44 0.66 0.22 0.44 0.66
MCCB
Rated Breaking 110V / 120V* 5 ─ ─ 10 ─ ─ 15 ─ 25/22** ─
ELCB Capacity (kA)
CNS 14816-2 220V / 240V* ─ 5*** 5 ─ 10 10 10 15 ─ 25/22**
Icu AC
#2 #3 380V / 400V* ─ ─ ─ ─ ─ ─ ─ 10 ─ ─
ATS Trip Unit Thermal Magnetic Thermal Magnetic Thermal Magnetic Thermal Magnetic
Plug in type
ACB Frame (AF) 50 100 50 100 50 100
MCB Appearance
Rated Voltage (A.C) #1 110/220* 220 110/220* 220 220 110/220* 380
SPD Rated Current In (A) 15, 20, 30 15, 20, 30, 40, 50 15, 20, 30 15, 20, 30 15, 20, 30, 40, 50
15, 20, 30, 40, 50. 60, 75100.
At Ambient Temp. 40℃ 40, 50. 60, 75, 100. 40, 50. 40, 50. 60, 75, 100.
a 25 50 75 25 50 75 50 75 25 50 75
MS
b 74 74 74 79
Dimensions
ca 74 74 74 77.5
MMS
bb ─ ─ ─ ─
(mm)
aa 0 25 50 0 25 50 25 50 0 25 50
Weight (kg) 0.13 0.26 0.39 0.13 0.26 0.39 0.33 0.53 0.18 0.36 0.54
110V / 120V* 5 ─ 10 ─ ─ 15 ─
Rated Breaking
Capacity (kA)
220V / 240V* ─ 5 ─ 10 10 10 15
CNS 14816-2
Icu AC
380V / 400V* ─ ─ ─ ─ ─ ─ 10
Trip Unit Thermal Magnetic Thermal Magnetic Thermal Magnetic Thermal Magnetic
Appearance
Rated Current In (A)
15, 20, 30, 40, 50.
At Ambient Temp. 40℃
Phase & Wire 1 2W
Number of poles (P) 2P1E 2P2E 2P1E 2P2E 2P1E 2P2E 2P1E 2P2E 2P1E 2P2E
Rated Voltage (A.C) #1. 110 220 220*** 220 110 220 220*** 220 220*** 220/380
Rated Current Sensitivity (mA) #2. 30, (100, 200, 300, 500)* 30 30, (100, 200, 300, 500)*
a 25 50 25 50 25 50 25 50 50 75
b 110 92 95 Index
Dimensions
c 60 60.5 58.5
Earth Leakage,
Overload Protection Earth Leakage Protection
Frame (AF) 30 40 30
ACB
Appearance
MCB
Rated Current Sensitivity (mA) #2. 30 30, (100, 200, 300, 500)* 30 MS
Max. Operating Time (s) ≦0.1S ≦0.1S ≦0.1S
Rated Breaking
110V~220V 1.5 1.5, 2.5 1.5 ─
Capacity (kA)
CNS 5422
Icu AC 380V~480V ─ ─ 1.5 MMS
a 66 90
b 70 70
Dimensions
c 42 42
ca 60 60
(mm) bb 59 59
aa 33 57
BM30-SN
BM50-CN
3P ─
BM60-SN/ HN
BM100-SN / MN
3P
BL50-SN ─ ─ ─ ─
4P
(#1.)
BM60-HBN
3P
BM100-HN ─
4P
BM125-SN/HN
(3P) (4P) (3P) (4P) (3P) (4P)
BL100-SN 3P
─ ─
BL100-HN 4P
Index No UVT for 3P (#2.) (#2.)
BM100-H/ HC/ HS
3P
BM160-HB/ HC/ HS ─
4P
BM250-HB/ HC/ HS
MCCB (#1.) (#1.) (#1.)
ELCB BM100-HBN
BM160-SN/ HN
BM250-SN/ HN 3P
BMA125-STA/LTA/HTA 4P
BMA160-STA/LTA/HTA
ATS BMA250-STA/LTA/HTA
BL160-SN 3P
─ ─ ─ ─
BL250-SN 4P
ACB
3P
BM400-SN/ HN/ RN/ UN
4P
AX can be installed
MCB in AL position
BL630-HN/ RN/ UN 3P
BL800-SN/ HN/ RN 4P
MMS
BM1000-HS
BM1200-HS 3P ─ ─
BM1600-HS
2P, 125AF and below : Accessories are installed on the right side.
Note:
1. Standard: AL and AX are installed on left side, SHT and UVT are installed on right side.
2. SHT is equipped with coil anti-burn switch.
3. BL series can not do right side installation.
● : AL
4. UVT of BM30-SN~BM100-HN can not install on its left side. Left Right
5. #1 means have no UVT. ○ : AX
6. #2 means only can apply to 4P breakers. : SHT or UVT
BO
20
Breaker & Switchgear System
Optional Accessories │ Application Table
Rotary Handle
TYPE Poles Model
Rear Connection
MS
TYPE Poles Model
Plate Breaker
Center of
breaker and
operation
Index handle
Thickness
Plate
Handle
MS Circuit breaker
Installation
Hinge
Manual hole
operation
65 or 95 Hinge
Handle
BO Plate(Handle) hole
dimension
22
Breaker & Switchgear System
Rear Connection
Dimensions (mm) Connect Direction
Type Poles
A A1 B B1 C D D1 E F G H H1 J K K1 K2 L M Horizontal Vertical
3 74 50 50
PGI-100N 24 58 90 ø5 / 116 M10 9.5 28 12 M10 / 62 122 M4 ◎ ◎
4 99 75 75
3 92 60 60
PGI-125N 30 70 104 ø6 / 134 M10 13 26 16 M10 / 62 122 M5 ◎ ◎
4 122 90 90
3 107 70 70
PGI-250N 38 76 106 ø6 ø10 144 25 13 34 15 6 / 79 134 M5 ◎ ◎
4 142 105 105
3 137 44 44
PGI-400N 50 135 175 ø10 ø13 225 28 18 40 24 8 120 79 / M8 ◎ ◎
4 181 88 88
Index
MCCB
ELCB
ATS
ACB
Rear Connection
Dimensions (mm) Connect Direction
Type Poles MCB
A A1 B B1 C D D1 E F G H H1 J K K1 K2 L M Horizontal Vertical
SPD
MS
MMS
BO
23
ATS(PC Class、MCCB、MS TYPE)
Rated Impulse
12kV
Withstand Voltage, Uimp
2P: AC220 / 230 / 240V
Rated Voltage, Ue
3/4P: AC380 / 400 / 415V
Control Voltage , Us AC220 / 230 / 240V, 50/60Hz
Rated Current, In (A) 16, 20 , 25, 32, 40, 50, 63 80, 100, 125 160, 200, 225, 250 350, 400, 500
Index Pole 2 3 4 2 3 4 2 3 4 2 3 4
Operation AC220/230
3 3 4 3 3 4 5 5 5 5 5 6
current (A) /240V
Tripping AC220/230
1 1.4
current (A) /240V
MCCB Rated condition
100kA 100kA 120kA 120kA
ELCB short circuit current (fuse)
Rated condition
50kA 50kA 65kA 65kA
short circuit current (breaker)
Making and Breaking Capacity AC-33B, DC-33B
ATS I -> II
Switching time ≤ 1s
II -> I
Electrical: 6000
Endurance
Mechanical: 20000
ACB Switching frequency 120 times / hr
2NO2NC on both source
AC110V, 5A
Auxiliary switch
AC220V, 3A
DC220V, 0.2A
MCB Note : AC-33A: Making & Breaking: 10Ie, cosφ=0.35
AC-33B: Making & Breaking: 10Ie, cosφ=0.35 (Ie≤100A, cosφ=0.45)
DC-33B:Making & Breaking: 4Ie, L/R=2.5ms
SPD
MS
Poles 2/3/4
AC380 / 220
Rated operation voltage (V) AC400 / 230
AC415 / 240
Rated operation frequency (Hz) 50 / 60
Optional functions ─
BO
24
ATS(PC Class、MCCB、MS TYPE)
800 1250 2500 5000
AC800V
12kV
AC400V
AC220V, 50Hz
630, 800 1000, 1250 1600, 2000, 2500 3200, 4000, 5000
3 4 3 4 3 4 3 4 Index
6 6 6 8 8 9 18 20
2
MCCB
120kA 120kA ─ 200kA
ELCB
50kA 50kA 50kA ─
ATS
≤ 1s
Electrical: 6000
Mechanical: 10000
120 times / hr ACB
2NO2NC on both source
AC110V, 5A
AC220V, 3A
DC220V, 0.2A
MCB
SPD
MS
Poles 2/3/4
AC380 / 220
Rated operation voltage (V) AC400 / 230
AC415 / 240
Rated operation frequency (Hz) 50 / 60
BO
25
ATS(PC Class、MCCB、MS TYPE)
Index
BS400SN 2P, 3P, 4P 50 35
250, 300, 350, 400.
BS400HN 2P, 3P, 4P 85 50
MCCB
ELCB BS630SN 3P, 4P 50 35
500, 600, 630.
BS630HN 3P, 4P 85 50
SPD
MS
MMS
B. MS Type
R, N 110V
Miniature Circuit Breaker
BS-MB 20A
Protection Switch
R, T 220V
BO
26
Air Circuit Breaker
Air Circuit Breaker
Rated operation voltage (Ue) AC400, 690V 50/60Hz AC400, 690V 50/60Hz AC400, 690V 50/60Hz AC400, 690V 50/60Hz AC400, 690V 50/60Hz
Rated insulation voltage (Ui) AC1000V 50/60Hz AC1000V 50/60Hz AC1000V 50/60Hz AC1000V 50/60Hz AC1000V 50/60Hz
Rated Impulse withstand voltage (Uimp) 12kV 12kV 12kV 12kV 12kV
Index
Number of pole 3/4 3/4 3/4 3/4 3/4 3/4
Type SN HS HN HS HN HS HN HS MCCB
ELCB
Rated breaking capacity
AC 690V 50 / 50 50 / 40 55 / 55 65 / 50 75 / 75 65 / 50 75 / 75 ─
Icw (kA)
AC 400V 50 50 65 65 85 65 85 100 ATS
@1 sec
AC 690V ─ ─ 55 ─ 75 ─ 75 ─
AC 400V 10000 8000 8000 8000 6500 6500 5000 5000 500
Electrical ACB
AC 690V 6500 5000 3000 3000 2500 2500 2500 2500 ─
Endurance
Without
15000 10000 10000 10000 10000 10000 10000 2500
maintenance
Mechanical
With
maintenance
20000 20000 20000 20000 20000 20000 20000 8000 MCB
Electronic tripping device E/A A/P A/P A/P A/P A/P A/P A/P A/P
3P 345x275x300 430 x 405 x 421 430 x 465 x 421 430 x 465 x 466
435 x 842 435 x 960 SPD
Drawout type x 505 x 505
HxWxL
Dimension
4P 345x345x300 430 x 500 x 421 430 x 580 x 421 430 x 580 x 466 435 x 956 x 492
3P 312x265x201 402 x 362 x 332 402 x 422 x 332 402 x 422 x 377 ─
Fixed type
HxWxL MS
4P 312x335x201 402 x 455 x 332 402 x 537 x 332 402 x 537 x 377 ─
Note: The rated breaking capacity indicated by voltage which marked with * are for reference.
MMS
BO
27
Miniature Circuit Breaker
BHA
•Overload, Short Circuit
BHA 2 2 C 32
↓ ↓ ↓ ↓ ↓
Rated short-circuit breaking
capacity (kA) Poles Tripping Mechanical
Type Rated current In (A) Standard
(P) characteristics life
Rated voltage (V)
2: 4.5kA; 3: 6kA; 4: 10kA C type: 5~ 10In 1, 2, 3, 4, 5, 6, 10, 16, 20, 000
BHA 1, 2, 3, 4 IEC 60898
230/400V D type: 10~ 15In 20, 25, 32, 40, 50, 63. operations
Index 10kA
1, 2, 3, 4, 5, 6, 10, 16, 20, 000
BHA 4: DC125V(1P) / DC250V(2P) 1, 2 DC Type IEC 60947-2
20, 25, 32, 40, 50, 63. operations
5: DC220V(1P) / DC440V(2P)
ATS BHL
•Overload, Short Circuit, Leakage
BHL 2 2 C 32 G
↓ ↓ ↓ ↓ ↓ ↓
ACB
Rated short-circuit breaking
capacity (kA) Poles Optional function
Type Tripping characteristics Rated current In (A)
(P) (2P)
Rated voltage (V)
2: 4.5kA; 3: 6kA C type: 5~ 10In Over-voltage protection
MCB BHL
230V
1P+N
D type: 10~ 15In
6, 10, 16, 20, 25, 32, 40.
(230V, internal built)
MS
BHL-A
MMS •Overload, Short Current, Leakage
BHL-A 3 1 C 32 A 30 G
↓ ↓ ↓ ↓ ↓ ↓ ↓ ↓
Rated short-circuit Rated
breaking capacity (kA) Poles Tripping Rated current Residual Optional function
Type sensitivity
(P) characteristics In (A) current type (2P)
Rated voltage (V) current (mA)
2: 4.5kA; 3: 6kA C type: 5~ 10In 6, 10, 16, 20, 25, 32, Over-voltage protection
BHL-A 1P+N A, AC 30, 100, 300
230V D type: 10~ 15In 40, 50, 63 (230V, internal built)
BO
28
Miniature Circuit Breaker
BL-BF
•Overload, Short Current, Leakage
BL-BF V 15 015 21
↓ ↓ ↓ ↓
Rated sensitivity
Model Type Rated current In (A) Pole
current I∆n (mA)
V : RCCB 000 : N/A (C Type) 20 : 2P0E
BL-BF L : RCBO 15, 20, 30 015 : 15 (V/L Type) 21 : 2P1E
C : MCB 030 : 30 (V/L Type) 22 : 2P2E
BHR-A
•Residual Current
BHR-A 42 25 A 030 Index
↓ ↓ ↓ ↓
Type Poles (P) Rated current In (A) Residual current Type Rated sensitivity current I∆n (mA)
42: 2P
030: 30 MCCB
BHR-A 25, 32, 40, 63 A, AC 100: 100
44: 4P
300: 300 ELCB
BHG ATS
•Disconnect Switch
BHG 2 32
↓ ↓ ↓
Type Rated voltage (V) Poles (P) Rated current In (A) Standard Mechanical life
ACB
BHG 230/400V 1, 2, 3, 4 32A, 40A, 63A, 80A, 100A. IEC 60947-3 50, 000 operations
MCB
BHN
•N+L Overload, Short Circuit
SPD
BHN 2 1 C 32
↓ ↓ ↓
Rated breaking capacity (kA)
Type Poles (P) Tripping characteristics Rated current In (A)
Rated voltage (V)
MS
2: 4.5kA; 3: 6kA
BHN 1P+N C type: 5~ 10In 6, 10, 16, 20, 25, 32.
230V
MMS
BHZ
•Over / Under Voltage Protective Device with Auto-reset
BHZ2 25
↓
Type Rated current In (A)
BO
29
Miniature Circuit Breaker
BHK
•Accessories
BHK 2 1
↓ ↓ ↓
Accessory Code Installation
Type
1 2 3 4 5 1 2
BHK AL AX SHT UVT OVT Standard Option
1NO. 1NC
230V 6A 9 BHK11
440V 3A
Index
AX
MCCB Auxiliary Contact
ELCB
1NO. 1NC
BHK21
230V 6A 9
BHK22
440V 3A
ATS
MCB 12
12-48
BHK31
24-48 18
BHK32
110-130
230-415
SPD
UVT
Under Voltage Trip
MS
BHK41
220-240 48 18
BHK42
MMS
BHK51
230V 15mA 280V±5% ≦0.2S 18
BHK52
BO
30
Surge Protective Device
Surge Protective Device │ BHP Series
BHP 20 ─ 3P R 320
↓ ↓ ↓ ↓ ↓
Connection wire
Alarm auxiliary
Imax/Limp Waveform Pole contact Uc Un Up Waveform In
diameter Index
Type
(kA) (µs) (P) R: with (V) (V) (kV) (µs) (kA)
Blank: without L-N PE
ACB
≧ ≧
BHP250 250: 25kA 10/350 440 230/400 ≦ 1.8 10/350 25
25mm² 35mm²
To enable the surge protective device to work, please read the following note:
1. The grounding system type of the protected device and maximum operating voltage of the power grid Us. Max.
2. The impulse withstand voltage of the protected device. MCB
Note: 1. BHP20, 40 are plug-in type; BHP80, 100, 250 are fixed type.
2. The standard operation voltage Uc(V) is below table. Max operation voltage Uc(V): 660V.
SPD
SPD Counter
Model TAD-04-99
MS
Rated Voltage 85~250V
Max. Count 99
•Voltage: the voltage continuously supplied between the wiring terminals of the surge protective device shall not exceed its maximum
continuous operating voltage Uc.
Model 06 09 11 12
ATS
Rated insulation voltage (V) AC660 AC660 AC660 AC660
NEMA 00 00 0 0
Contact class (UL) A600 A600 A600, P600, Q300 A600, P600, Q300
Electrical Life AC3 1.6 Mil. 1.6 Mil. 1.6 Mil. 1.6 Mil.
MMS
Mechanical Life 10 Mil. 10 Mil. 10 Mil. 10 Mil.
4-M4
32
Magnetic Contactor / Motor Starter ◆ AC control
Motor Starter
Model 15 16 21 (A) 25
ATS
Rated insulation voltage (Ui) (V) AC660 AC660 AC660 AC660
100~120V - 1/ 16 2/ 24 2/ 24
1ø
200~240V - 3/ 17 3/ 17 3/ 17
UL 508 200~240V - 5/ 15.2 7.5/ 22 10/ 28
ACB
CSA-C22.2
NEMA 0 0 1 1
Standard 1NO 1NO 1NC 1NO 1NC (2NO 2NC) 1NO 1NC SPD
Auxiliary Contact
Special 1NC - - -
IEC 60947-5-1 Contact
EN 60947-5-1
220V 1.6 1.6 1.6 1.6
GB14048.4
Electrical Life AC3 1.3 Mil. 1.3 Mil. 1.3 Mil. 1.3 Mil.
MMS
Mechanical Life 10 Mil. 10 Mil. 10 Mil. 10 Mil.
15/ 20/ 30 18.5/ 25/ 35 22/ 30/ 40 30/ 40/ 52 37/ 50/ 65
MCCB 15/ 20/ 27 18.5/ 25/ 27 22/ 30/ 40 30/ 40/ 52 37/ 50/ 65
ELCB 15/ 20/ 22 18.5/ 25/ 22 22/ 30/ 32 30/ 40/ 41 37/ 50/ 52
15/ 20/ 18 18.5/ 25/ 18 22/ 30/ 26 30/ 40/ 34 37/ 50/ 43
50 50 60 80 90
ATS
AC660 AC660 AC660 AC660 AC660
2/ 24 2/ 24 3/ 34 5/ 56 5/ 56
MCB 50 50 60 80 90
2 2 2 2 2
SPD 2NO 2NC 2NO 2NC 2NO 2NC 2NO 2NC 2NO 2NC
- - - - -
16 16 16 16 16
A600, Q300 A600, Q300 A600, Q300 A600, Q300 A600, Q300
1.3 Mil. 1.3 Mil. 1.3 Mil. 1.3 Mil. 1.3 Mil.
MMS
10 Mil. 10 Mil. 10 Mil. 6 Mil. 6 Mil.
34
Magnetic Contactor / Motor Starter ◆ AC control
Motor Starter
Model 80T 100T 125T 150T
380/415V 45/ 60/ 80 60/ 80/ 105 75/ 100/ 130 90/ 125/ 160
IEC 60947-4-1
EN 60947-4-1
3ø 440V 45/ 60/ 75 60/ 80/ 105 75/ 100/ 130 90/ 125/ 160 MCCB
DIN VDE 0660
550V 45/ 60/ 60 60/ 80/ 85 75/ 100/ 105 90/ 125/ 130
ELCB
AC 3
(kW/HP/A) 660V 45/ 60/ 50 60/ 80/ 70 75/ 100/ 90 90/ 125/ 110
ATS
Rated insulation voltage (Ui) (V) AC660 AC660 AC660 AC660
100~120V 7.5/ 80 - - -
1ø
200~240V 15/ 68 - - -
UL 508 200~240V 25/ 68 30/ 80 50/ 130 60/ 154
ACB
CSA-C22.2
NEMA 3 3 3 3
Standard 2NO 2NC 2NO 2NC 2NO 2NC 2NO 2NC SPD
Auxiliary Contact
Special - - - -
IEC 60947-5-1 Contact
EN 60947-5-1
220V 1.6 1.6 3.3 3.3
GB14048.4
Contact class (UL) A600, Q300 A600, Q300 A600, Q300 A600, Q300
Electrical Life AC3 1.2 Mil. 1.2 Mil. 1.2 Mil. 1.2 Mil.
MMS
Mechanical Life 6 Mil. 6 Mil. 6 Mil. 6 Mil.
4-M5
MS-P200T MS-P220T - - -
MS-2×P200T MS-2×P220T - - -
- - - - -
110/ 150/ 200 120/ 160/ 220 160/ 220/ 300 220/ 300/ 400 315/ 420/ 600
MCCB 110/ 150/ 190 120/ 160/ 220 185/ 250/ 300 250/ 340/ 400 315/ 420/ 600
ELCB 110/ 150/ 150 132/ 180/ 180 185/ 250/ 263 250/ 340/ 360 315/ 420/ 500
110/ 150/ 125 132/ 180/ 150 200/ 300/ 220 280/ 380/ 305 -
- - - - -
- - - - -
ACB 75/ 192 75/ 192 100/ 248 125/ 312 -
4 4 5 5 6
SPD 2NO 2NC 2NO 2NC 2NO 2NC 2NO 2NC 2NO 2NC
- - - - -
16 16 10 10 16
A600, Q300 A600, Q300 A600, Q300 A600, Q300 A600, Q300
1.2 Mil. 1.2 Mil. 1.2 Mil. 1.2 Mil. 0.6 Mil.
MMS
6 Mil. 6 Mil. 6 Mil. 6 Mil. 6 Mil.
8-M6
60
36
Magnetic Contactor / Motor Starter ◆ DC control
Motor Starter
Magnetic
Nonreversing SD-P11 SD-P16 SD-P21
Contactor
Reversing SD-2×P11 SD-2×P16 SD-2×P21
Nonreversing - - -
Starter with
enclosure Reversing - - -
with enclosure
(push button)
Nonreversing - - -
NEMA 0 0 1
MS
Magnetic Contactor
2-M4 43 2-M4
35 35
70
BO
37
Capacitor Contactors
Motor Starter
Rated Insulation voltage (Ui) (V) 690 690 690 690 690 690 690
Auxiliary Contact 2NO or 1NO 1NC 2NO 1NC 2NO 1NC 3NO 2NC 3NO 2NC 3NO 2NC 3NO 2NC
100~120V 6 6 6 6 6 6 6
Auxiliary Contact
AC12 200~220V 5 5 5 5 5 5 5
IEC 60947-5-1 (A) 380~440V 3 3 3 3 3 3 3
Index EN 60947-5-1
550~600V 3 3 3 3 3 3 3
Continuous current (Ith) (A) 16 16 16 16 16 16 16
Mechanical Life / Electrical Life (AC-6b) ≦440V (10 thousand) 100 / 30 100 / 30 100 / 30 100 / 30 100 / 30 100 / 30 100 / 30
MCCB
Operation frequency (time/ hour) 240 240 240 240 240 240 100
ELCB
Capacitor unit AP-40 A AP-40 A AP-40 A AP-40 B AP-40 B AP-40 B AP-40 B
Appearance Dimensions (H×W×D) (mm) 44×108×134 54×112×134 54×112×134 74×185×144 89×185×158 89×185×158 101×195×168
ATS 4-M4 4-M4 4-M4 4xM5
40 4-M4
35 34 78 86
Installation Dimension
64.7
(mm)
74
60.5
50
50
60
54
48
50
60
74
79
90
ACB 35 64
MCB
Capacitor Unit
S-P21 10 20 30 1250
S-P40T 15 25 36 1900
MMS
S-P50T 20 33.3 48 2160
AP-40-B
S-P60T 25 45 58 3040
S-P80T 35 60 75 3040
BO
38
Thermal Overload Relay
Motor Starter
Type 09 12 20
#3
Separate Installed Type - TH-P12PPR - -
Rating (A) Range (A) Rating (A) Range (A) Rating (A) Range (A) Rating (A) Range (A)
Index
0.13 0.1~0.16 0.25 0.19~0.31 0.25 0.19~0.31 28 22~34
21 17~24 SPD
TH-P12(PP):
TH-P12(PP)R:
35
M4
27.5
36.5x27.5
Installation Dimensions (mm) - M4
34x52
60
56
52
M4
35x56/60
36.5
34
Note. 1. The purpose of using TOR is protecting load tripping. For protecting circuit, please choose circuit breaker. BO
2. When adjusting the rated current; please refer to the TOR range table above. Do not exceed its range.
3. (E): 3 Elements 39
4. ✽: The rating current of TH-P12 can only use up to "11A" when combined with S-P11. Correct Incorrect
Motor Starter
- - - - - - -
- - - - - - -
Manual / Automatic Manual / Automatic Manual / Automatic Manual / Automatic Manual / Automatic
S-P50T, S-P60T,
S-P60T, S-P80T. S-P100T, S-P125T, S-P150T. S-P200T, S-P220T. S-P300T, S-P400T. M-600C
S-P80T.
15 12~18 80 60~100 54 43~65 130 100~160 105 80~130 130 100~160 350 260~440
MCCB
ELCB 21 17~24 67 54~80 160 120~200 130 100~160 160 120~200 500 400~600
54 43~65
ACB
MCB
SPD
1NO 1NC 1NO 1NC 1NO 1NC 1NO 1NC 1NO 1NC
0.28/ 0.30 0.34/ 0.36 0.55 0.76 2.25 2.65 3.93/ 3.95
MS
TOR:
64.5×46.1×80
TH-P60(PP): TH-P60TA(PP): TH-P120(PP): TH-P120TA(PP):
140×151.5×158.7 164×165×163.7
98×50.5×78 64.5×65.5×80 133×54×105 133×85.5×105
TOR W/CT:
MMS 106×46.8×104.5
Ø 5.2 Ø 5.2
27.5
33.2
M5 M5 M4
35
Ø 5.2
Ø 5.2
86 119 95 36.5
90
BO
40
Motor Starter
Magnetic Control Relays
8NO
5NO
4NO 7NO 1NC
4NO 1NC
Auxiliary Contact 3NO 1NC
3NO 2NC
6NO 2NC
2NO 2NC 5NO 3NC
2NO 3NC
4NO 4NC
ATS
Definite Purpose Magnetic Contactor │ SF Series
20 25 30 35 40
ACB
C1 C2 C3
Type
MCB
BO
41
Motor Starter
Star-delta Starter
Without enclosure (no CT) SDO-P21 SDO-P35 SDO-P50 SDO-P60 SDO-P80 SDO-P100 SDO-P125 SDO-P150 SDO-P220
SDO- SDO- SDO- SDO-
Without enclosure (with CT) SDO-P21T SDO-P35T SDO-P50T SDO-P60T SDO-P80T
Type P100T P125T P150T P220T
With enclosure (no Ammeter) SDE-P21 SDE-P35 SDE-P50 SDE-P60 SDE-P80 SDE-P100 SDE-P125 SDE-P150 SDE-P220
With enclosure (With Ammeter) SDA-P21 SDA-P35 SDA-P50 SDA-P60 SDA-P80 SDA-P100 SDA-P125 SDA-P150 SDA-P220
Rated 200V~220V 11/ 15 19/ 25 22/ 30 30/ 40 37/ 50 45/ 60 55/ 75 75/ 100 110/ 150
Capacity
(kW/HP) 380V~440V 19/ 25 30/ 40 45/ 60 55/ 75 75/ 100 90/ 125 110/ 150 132/ 180 200/ 260
MCM S-P21 S-P35T S-P50T S-P60T S-P80T S-P100T S-P125T S-P150T S-P220T
AC
Magnetic MCD S-P21 S-P35T S-P50T S-P60T S-P80T S-P100T S-P125T S-P150T S-P220T
Contactor
MCS S-P11 S-P16 S-P21 S-P21 S-P35T S-P35T S-P50T S-P50T S-P60T
ATS
Green Green
Red Red
Green Green Green
Red Green Red
Contact
schema
Green Red
Green RedGreen Green Green Red Green Red
ACB
MCB
External dimensions (mm)
SPD
+ =
BO Type UATP12
42 TOR TH-P12
Motor Starter
Auxiliary Contact Block
◆ AP Series
Installation 2P FRONT MOUNTED TYPE 4P FRONT MOUNTED TYPE SIDE MOUNTED TYPE
Model AP-20 AP-11 AP-02 AP-40 AP-31 AP-22 APS-11 APL-11
Contact 2NO 1NO 1NC 2NC 4NO 3NO 1NC 2NO 2NC 1NO 1NC 1NO 1NC
220V 1.6
Rated Capacity
AC 15 (A)
380V 0.95
Index
Auxiliary Contact Block
◆ MAP Series
Installation 2P FRONT MOUNTED TYPE 4P FRONT MOUNTED TYPE MCCB
Model MAP-20 MAP-11 MAP-02 MAP-40 MAP-31 MAP-22 ELCB
Contact 2NO 1NO 1NC 2NC 4NO 3NO 1NC 2NO 2NC
Timer
MCB
220V 1.6
Rated Capacity
AC 15 (A) MS
380V 0.95
MMS
Surge unit
Model BMSACW220V BMSACW380V
Applicable contactor SR-P40, SR-P50, S-P11~ S-P60T.
Mechanical Interlock
Model MPU-11 MPU-21 MPU-50 BO
Applicable contactor S-P11/S-P15/S-P35T~60T S-P12/S-P16~30T S-P80T 43
Characteristics
Motor Starter
S-P16
S-P50T
S-P06 S-P11 S-P21 S-P35T S-P125T S-P200T S-P300T
Model S-P12 S-P60T S-P100T M-600C
S-P09 S-P15 S-P25 S-P40T S-P150T S-P220T S-P400T
S-P80T
S-P30T
On 55~70% 55~68% 55~68% 59~70% 60~75% 63~75% 65~75% 75~80% 75~80% 65~80% 72~79%
Operation
Vot. (Ue)
Off 35~50% 34~48% 34~48% 36~52% 40~57% 40~57% 40~55% 40~55% 40~60% 20~50% 59~66%
Aux. OFF 5-12 5-12 4-11 6-14 6-13 6-13 18-28 9-20 10-19 22-37 42-71
Close Time
(ms)
Aux. ON 6-15 10-18 10-18 10-18 12-20 12-20 22-32 15-24 17-25 25-40 49-78
Contact ON 6-15 10-18 10-18 10-18 12-20 12-20 22-32 10-20 12-27 30-45 51-80
Aux. OFF 6-15 12-20 9-18 9-19 10-17 10-17 50-100 9-18 10-20 40-60 61-97
Open Time
Aux. ON 5-12 8-15 4-13 6-14 5-12 5-12 48-98 7-15 7-18 31-51 58-94
Index (ms)
Contact ON 5-12 8-15 4-13 6-14 5-12 5-12 46-96 7-15 7-20 30-50 57-93
MCCB
ELCB
ACB 12V 50Hz 24V 50Hz 48~50V 50Hz 100V 50Hz 110~120V 50Hz 200~220V 50Hz
Coil rated specifications marking
12V 60Hz 24V 60Hz 48~50V 60Hz 100~110V 60Hz 115~120V 60Hz 220V 60Hz
230V 50Hz 220~240V 50Hz 346~380V 50Hz 400V 50Hz 415~440V 50Hz 500V 50Hz
MCB Coil rated specifications marking
460~480V 60Hz
230V 60Hz 240~260V 60Hz 380V 60Hz 400~440V 60Hz 500~550V 60Hz
SPD ◆ S-P300T~P400T
MMS ◆ M-600C
100V 50Hz 110~120V 50Hz 208~220V 50Hz 230~240V 50Hz 240~260V 50Hz
Coil rated specifications marking
100~110V 60Hz 115~120V 60Hz 220V 60Hz 230~240V 60Hz 260~280V 60Hz
BO
44
Selection Table ◆ Direct On-Line Starter
Motor Starter
3 ø 200V~220V
Motor rated
capacity kW (HP)
Heating element rating (A) Selection of the contactor
S-P06
S-P09
0.12 (1/6) 0.8A 0.6~1.0A
ELCB
S-P15, S-P16
S-P30T
ATS
S-P40T
28A 22~34A
S-P80T
7.5 (10)
MS
25 (35)
105A 80~130A
30 (40)
S-P200T
55 (75)
S-P400T
200A 150~250A
65 (85)
90 (125)
M-600C
350A 260~440A
110 (150)
132 (180)
500A 400~600A
160 (220)
BO
45
Selection Table ◆ Direct On-Line Starter
Motor Starter
3 ø 380V~440V
Motor rated
capacity kW (HP)
Heating element rating (A) Selection of the contactor
S-P06
0.37 (1/2) 1.3A 1.0~1.6A
S-P09
0.55 (3/4)
2.0A 1.6~2.4A
0.75 (1)
1.5 (2)
5A 4.0~6.0A
2.2 (3)
S-P25
S-P35T
3.7 (5)
9A 7~11A
ACB 4 (5 1/2)
4.5 (6)
11A 9~13A
5.5 (7 1/2)
S-P60T
22 (30)
40A 32~48A
25 (35)
37 (50)
S-P125T
67A 54~80A
S-P150T
45 (60)
S-P220T
S-P400T
110 (150)
200A 150~250A
132 (180)
160 (220)
M-600C
350A 260~440A
220 (330)
250 (350)
500A 400~600A
315 (420)
BO
46
Selection Table ◆ Direct On-Line Starter
Motor Starter
3 ø 500V~550V
Motor rated
capacity kW (HP)
Heating element rating (A) Selection of the contactor
S-P06
0.55 (3/4) 1.3A 1.0~1.6A
S-P09
0.75 (1)
2.0A 1.6~2.4A
1.1 (1 1/2)
2.2 (3)
5A 4.0~6.0A
3 (4)
S-P25
S-P35T
5.5 (7 1/2)
11A 9~13A
7.5 (10) MCB
11 (15) 15A 12~18A
S-P50T
12 (16)
S-P60T
21A 17~24A
S-P80T
15 (20)
SPD
19 (25) 28A 22~34A
S-P125T
45 (60)
S-P150T
67A 54~80A
50 (70)
110 (150)
S-P400T
160A 120~200A
132 (180)
BO
47
Selection Table ◆ λ-Δ Starter
Motor Starter
200~220V 380~440V A B A B A B A B A B A B A B A B A B
TH-P20
TH-P20
11 3 (4) 5.5 (7 1/2)
MCCB
28 6.5 (8) 14 (19)
ELCB
TH-P60
TH-P60
TH-P60
TH-P60
TH-P20TA
ATS
33 9 (12 1/2) 19 (25)
40 11 (15) 22 (30)
ACB
40 14 (19) 26 (35)
54 15 (20) 30 (40)
TH-P120
TH-P120
TH-P120
TH-P120
TH-P120
TH-P120
MCB
P60TA
TH-
67 19 (25) 37 (50)
TH-P60TA
TH-P60TA
80 22 (30) 45 (60)
SPD
80 25 (34) 50 (67)
P120TA
P120TA
TH-
TH-
TH-P120TA
TH-P220T
TH-P220T
TH-P120TA
TH-P120TA
TH-P220T
TH-P220T
TH-P400T
BO
48
Motor Starter
Modular Contactor
Pole 2P 4P 2P 4P 2P 4P 2P 4P
Rated insulation voltage (Ui) IEC (V) 500 500 500 500 500 500 500 500
Rated operational voltage (Ue) IEC / UL (V) 230 400 250 400 250 400 250 400
AC-7a (A) 16 16 25 25 40 40 63 63
Rated operational current
AC-7b (A) 6 6 8.5 8.5 15 15 20 20 Index
Continuous Current (Ith) (A) 25 25 25 25 63 63 63 63
ATS
Accessory
ACB
•Side mount auxiliary contacts
MCB
MMS
Model Usage
BO
49
MANUAL MOTOR STARTER
Magnetic Switch
Overload adjustable
Power factor AC-3 Rated current Tripping current (A) Type
range
MS
MMS
AL (MR-AM) UVT (MR-AU)
(For Magnetic Trip)
AL (MR-AD)
(For Overload Trip)
MMS
BO
50
MAGNETIC CONTACTOR / SWITCH (CONTACTOR/ MS/ MMS), CIRCUIT BREAKER (MCCB/ ELCB/ EMCCB/ MCB), AIR CIRCUIT BREAKER,
AUTOMATIC TRANSFER SWITCHES, SURGE PROTECTIVE DEVICE, SMART METER, LOW VOLTAGE POWER CAPACITORS, INVERTER