USER MANUAL
MODEL: OCS-S9
USER MANUAL
Manual_OCS-S9_V1
TABLE OF CONTENTS
USER MANUAL 1
SAFE OPERATION GUIDE:
1. The capacity of crane scale have been showed on the overlay, Don’t make lifts beyond
rated capacity of the crane scale.
3.The scale must be routinely checked for operation. Don’t operate if hook, shackle, sling,
cable, etc show any sign of defects or excessive wear.
4. If the scale is not going to be used for long time, recharging the battery every three
months to preserve the life-span of the battery and recharge it before operation.
5. The battery charger is included in the scale package. Please use this charger, It’s
normal that the charger will become warm when the battery is charging.
6. Please note when the digits flash on the display, it means that the battery needs to be
recharged.
7. Check hook, shackle, safety pins, and latches periodically. Contact your dealer for
USER MANUAL 2
CHAPTER 1 FEATURES AND SPECIFICATION
1. Features
◆ Blue-tooth wireless communication and display
Many functions on Mobile(android system). Such as tare, zero, peak, accumulation. Two display,
one display on Mobile,one display on crane scale,
◆ Two set point
Two user programmable Set-Point can be used for safety and warning applications or for limit
weighing.
◆ User-friendly design:
Cast aluminium scale housing for maximum protection; Large red 5 digit LED display (digit height
30mm); Gravity compensation; Safety factor up to 4 times capacity; Battery Operated with low
battery indication; Automatic turn off , power-saving function.
USER MANUAL 3
3. Specification
Max. capacity Min. weigh Division Total display counts
MODEL
(kg) (kg) (kg) (n)
OCS-SB-1 1000 10 0.5 2000
OCS-SB-2 2000 20 1 2000
OCS-SB-3 3000 20 1 3000
OCS-SB-5 5000 40 2 2500
OCS-SB-10 10000 100 5 2000
OCS-SB-15 15000 100 5 3000
OCS-SB-20 20000 200 10 2000
4. Appearance illustration
USER MANUAL 4
5. Scale power supply
Battery: 6V/7Ah fully sealed Lead-Acid battery
Adapter: 9VDC/1000mA adapter
Current: the crane scale average current is about DC 100mA±10%, if battery charged, it can be used for
about 50hours.Low battery warning: When the digits flash, it means the battery needs to be recharged.
The scale will power off automatically after 1 to 2 hours operation if the battery is not charged. Please
recharge the battery before operating the scale again.
Charging method: Turn off the crane scale, use adapter in the carton, the charge lamp on the back cover
will become orange when charging, and it will become green when the charging finish.
Generally, charging time should not less than 8hours, the crane scale have charging protection, long
time charging can’t damage the battery.
1. SCALE DISPLAY
1. LED DISPLAY
30mm (1.2’’) 5digits LED/LCD
2. INDICATOR LAMP
a. TARE: TARE indicator
b. STB: STABLE indicator
3. KEY
a. ON/OFF
1. Press ON/OFF three seconds,the crane scale turn on.
2. When turn on,Press ON/OFF three seconds,the crane scale turn off.
b. TARE
1. Hang sling or container on the hook, when the weight reading stable, press this key, the digits
display “0”, and “TARE” indicator switch on.
2. Put the goods into container, the scale will display goods net weight.
3. If move goods and container, the scale will display minus value of tare weight.
USER MANUAL 5
2. Mobile display
1. Install APP software to mobile
This is android system! Android 2.0
1. Download the APK software(Everight-1-2P) to mobilephone
2. Running the software
3.Search and press button “BT-2015”
First time there are no paired devices inside, press “Scan for device” to search paired device.
After the paired device display, press it.
It will request you input device pin, input pin: 6666,then press Enter, the mobilephone will display
2 ZERO
OPERATION DISPLAY When scale turn on, generally scale displays〖 0〗,if
Press (ZERO) 〖 0〗 display small digits when no load, press this key.
Press【ZERO】 〖 0〗
USER MANUAL 7
3 TARE
◆ TARE DIRECTLY
OPERATION DISPLAY After turn on, hanging tare weight such as sling, cable
1 Press (TARE) 〖 0〗 at first, press this key, “TARE” light on, then the scale
2 Press TARE on 〖 0〗 will display net weight of the goods.
the scale
3 Press【TARE】 〖 0〗
4 PEAK
OPERATION ILLUSTRATION
Press (PEAK) Hold the maximum weight reading when load change
Press (PEAK) again Return to normal weighing status
5 HOLD
OPERATION ILLUSTRATION
Press 【HOLD】 Hold the weight reading no matter load change
Press 【HOLD】 again Return to normal weighing status
6 ACCUMULATION
OPERATION DISPLAY ILLUSTRATION
Press【ACCU】 〖No***〗 Current accumulation time
or (ACCU) 〖H****〗 Front four digits of total value
〖L****〗 Rear four digits of total value
After display above contents two times, the scale will return automatically, you also can press
【SHIFT】to return.
7 ACCUMULATION SEARCH
OPERATION DISPLAY ILLUSTRATION
Press 【 SHIFT 】 〖No.***〗 Current accumulation time
【 ACCU 】 or 〖 ***** 〗 Current weight reading
(search ACCU)
〖H****〗 Front four digits of total value
〖L****〗 Rear four digits of total value
【SHIFT】 〖*****〗 Return
Press【TARE】and【ZERO】can check different times weight and accumulation.
8 ACCUMULATION CLEAR
OPERATION DISPLAY ILLUSTRATION
【CLEAR】or (CLEAR) 〖 CLr 〗 Ask if you want to clear or not
【CLEAR】or (CLEAR) 〖noCLr〗 Cancel clear
【SHIFT】 〖8.8.8.8.8.〗 Confirm clear
USER MANUAL 8
9 BATTERY VOLTAGE
OPERATION DISPLAY ILLUSTRATION
【SHIFT】【F1】 〖U 6.**〗 Display current battery voltage
【SHIFT】 Return
The voltage should be between 5.8 and 6.9, if below than 5.8, the digits flash, you need to
recharge immediately.
10 SET POINT
There are two user programmable Set-Point can be used for safety and warning applications
or for limit weighing.
_ 1 LO SP1 1 HI 2 LO SP2 2 HI
USER MANUAL 9
CHAPTER 4 PARAMETER SETTING &CALIBRATION
You need to use remote controller to operate parameter setting and calibration
Key function:
KEY FUNCTION
【TARE】 Move digit(the digit choose flash)
【ZERO】 Set value up
【CLEAR】 Set value down
【SHIFT】 Confirm, exit
1. PARAMETER SETTING
OPERATION DISPLAY ILLUSTRATION
Press ON/OFF 3seconds 〖 0〗 Turn on crane scale
Press 【F1】and 【F2】 〖P0000〗 Second digit flash,use function key to move
at same time 3seconds digit, set value.
Press 【 TARE 】【 ZERO 】 〖P8088〗 Input 8088,8088 is parameter setting password
【CLEAR】
Press【SHIFT】 〖SETUP〗 Confirm, enter parameter setting program
Press【TARE】 〖FS=06〗 New scale,the screen display FS=06,if scale
calibrated,the screen display capacity.
Press【ZERO】or【CLEAR】 〖FS=05〗 Choose capacity , the screen display
to choose 02/03/05/06/10/15/20/30/50/60/75 circularly ,
take cap:5000kg as example, choose FS=05
Press【TARE】confirm 〖Id=05〗 New scale,the screen display Id=05, if scale
calibrated , the screen display calibrated
division.
Press【ZERO】or【CLEAR】 〖Id=02〗 Choose division , the screen display
to choose 01/02/05/10/20 circularly. 5000kg scale division
is 2kg, so choose Id=02
〖Pt=0〗 New scale,the screen display Pt=0, if scale
calibrated , the screen display calibrated
decimal position
Press【ZERO】or【CLEAR】 〖Pt=0〗 Choose decimal position, the screen display
to choose 0/1/2/3 circularly, 0=xxxxx, 1=xxxx.x, 2=xxx.xx,
3=xx.xxx,Cap.5000kg scale choose Pt=0
Press【TARE】confirm 〖Ab=24〗 Display zero range , A: zero range by hand; B:
zero range automatically, 0~5 total 6 options:
0=0%F. S; 1=2%F.S; 2=4%F.S; 3=10%F.S;
4=20%F.S; 5=50%F.S,Generally,Don’t change
this parameter.
Press【TARE】confirm 〖Cd=11〗 New scale,the screen display Cd=11,if scale
calibrated,the screen display calibrated value.
USER MANUAL 10
2. The capacity you choose relate to division, decimal position, below is detail list:
CAPACITY/DIVISION FS (CAP) Id (DIVISION) Pt(DECIMAL POSITION)
1000kg/0.5kg 10 05 1
2000kg/1kg 02 01 0
3000kg/1kg 03 01 0
5000kg/2kg 05 02 0
10000kg/5kg 10 05 0
15000kg/5kg 15 05 0
20000kg/10kg 20 10 0
2. calibration
OPERATION DISPLAY ILLUSTRATION
〖 0〗 Take Cap:5000kg scale as example,Pay attention that
the screen display 0 after hanging tare weight, you can
hang tare weight at first, then turn on.
Press 【F1】and 【F2】 〖P0000〗 Second digit flash,use function key to move digit, set
at same time value.
3seconds
Press 【 TARE 】 〖P1358〗 Input 1358,1358 is calibration password
【ZERO】 【CLEAR】
Press【SHIFT】 〖SCALE〗 Confirm,into calibration program
Press【SHIFT】 〖CALSP〗 Zero point calibration, wait until STB light on
Press【SHIFT】 〖LoAd1〗 First load calibration
Hanging on first load First load must exceed 20% capacity, Waiting until STB
e.g.1000kg light on.
Press【SHIFT】 〖05000〗 Display capacity
Press 【 TARE 】 〖01000〗 Input 1000, wait until STB light on.
【ZERO】 【CLEAR】
Press【SHIFT】 〖LoAd2〗 Second load calibration
Hanging on second Second load must exceed Load 1+20% capacity,
load e.g.3000kg Waiting until STB light on.
Press【SHIFT】 〖02000〗 Mention you Load2 must exceed 2000kg
Press 【 TARE 】 〖03000〗 Input actual weight 3000, waiting stable
【ZERO】 【CLEAR】
Press【SHIFT】 〖LoAd3〗 Third load calibration
Hanging on third load Third load must exceed Load 2+20% capacity, Waiting
e.g.5000kg until STB light on.
Press【SHIFT】 〖04000〗 Mention you Load3 must exceed 4000kg .
Press 【 TARE 】 〖05000〗 Input actual weight 5000kg. wait until STB light on.
【ZERO】 【CLEAR】
Press【SHIFT】 〖------ -〗 Waiting stable
USER MANUAL 12
〖 -oL- 〗
〖 End 〗 Calibration end
〖5000.0〗 Display calibrated capacity , sometimes it display
4999.5, 5000.5
Press【TARE】 〖05000〗 Move decimal position
Put down weight 〖 0〗 Check zero point, it display 0, and STB, ZERO light on.
1. First load: LOAD1 must larger than 20% capacity,and LOAD1<LOAD2<LOAD3, at the same
time, between LOAD1 and LOAD2, LOAD2 and LOAD3, the interval must bigger than 20%
capacity
2. If LOAD1 is bigger than 80% capacity, such as full capacity, after first load calibration, it will
finish automatically, you only need to press【TARE】to move decimal position. Generally, we
strong recommend you to use this one point calibration program if you have 100% capacity
standard weight
3. If you only have 20% standard weight, after first load calibration, when it display 〖LoAd2〗,
Display experiences Scale electronics do not After turning on, heating 3-5
excessive Zero drift stabilize after turning on minutes.
between weighment Put the scale on ground for Scale should be hung
too long time
Displayed weight Scale not Zeroed before Depress ZERO before
shows large error applying weight applying weight
Requires recalibration See calibration
Kg/lb wrong selection See operation
Battery can’t recharge Battery damaged Replace battery
Outlet damaged Replace the outlet
Remote distance Receiver window is dirty Check and clean
shortened
Remote Control’s battery is Replace Remote Control’s
low battery.