Author Message

me_onnetwork Posted: Wed May 16, 2012 11:39 am Post subject: Application of Crane Load in Staad
SEFI Regulars

Hi Sefians.
Joined: 19 Jan 2009
Posts: 20
I am analysing an Industrial Building in Staad.pro. Its a Power House structure of a Hydro-Power
Project.

The structure is in Earthquake Zone V. The structure contains steel Roof Truss supported on RCC
Columns. In My first step I have designed the Steel roof truss for wind load. Now, for designing the
beam columns I have applied the earthquake load.
In the Power House there is a 150/25 t EOT Crane.

After applying DL, LL, EL/WL I am stuck in the Crane load part.

Maximum Static AXle Load (From Manufacturer) = 50t / axle

1.Shall I apply a moving Load on the Gantry Girder or shall I apply Point Loads on each column
with a definite Impact factor.

2. How generally Gantry girders and columns supported them are analysed and Designed in Staad.

3. Which Method can save my time.

Your Suggestions would be of great guidance to me.

Thanks & Regards


Bhawna

Back to top

zubairmeer1 Posted: Wed May 16, 2012 1:08 pm Post subject:


General Sponsor

While applying gantry girder loads... we apply the maximum reaction in gantry girder on
columns...in case of eccentricity(due to corbel) moment due to ecc. is also added...

the procedure for obtaining max reaction is

Joined: 27 Feb 2010 1) Calculate the maximum reaction of crane girder on gantry girder(please refer any steel book,
Posts: 88 Steel structures by Dr. N. Subramanian is very good )
Location: Hyderabad

2) Calculate the max reaction at support of gantry girder due to crane reaction...u can find in the
above book the position of loads to get max. shear

3) also calculate the horizontal forces along the rails and across the rails and incorporate the same
in the model.

https://www.sefindia.org/forum/viewtopic.php?p=47490 1/4
4/17/2018 www.sefindia.org :: View topic - Application of Crane Load in Staad
regards

Meer

Back to top

VPandya Posted: Wed May 16, 2012 4:51 pm Post subject: Use AISC Design Guide 7 for applying CRANE
General Sponsor LOADS.

Dear Sefian,

Use AISC Design Guide 7 for applying CRANE LOADS. This is the most complete Design Guide
on Industrial Structures with Crane Loads. Should answer most of your questions. Then go
and model it in STAAD/PRO as required in this Design Guide.
That part is easy.

Joined: 09 Nov 2009


Industrial Buildings
Posts: 688
Location: Ahmedabad

Roofs to Anchor Rods


AMERICAN INSTITUTE OF STEEL CONSTRUCTION,
INC.

Second Edition
James M. Fisher
Computerized Structural Design, Inc.

Milwaukee, WI

Regards.

Vasudeo Pandya P.E. ; S.E.


Structural Engineer

Back to top

TBSPL_6 Posted: Wed May 16, 2012 6:33 pm Post subject: Re: Application of Crane Load in Staad
SEFI Regulars

HI SEFIAN
Joined: 17 Jan 2009
Posts: 30 QUERY1. LZ APPLY A MOVING LOAD BY AFTER CALCULATING MAX FY AND FX ON THE GANTRY
GIRDER AND CHECK FOR DEFLECTION AS PER AISC .

Q2.ON THE RCC BRACKETS , WE HAVE TO GIVE ANCHOR BOLTS TO ACOMMODATE GANTRY
GIDRER WITHOUT FAIL , FOR THE RECTION WHICH IS COMING OVER THE RCC BRACKET .

Q3. FOR SUCH TYPE OF COMPLICATED JOBS EVEN THOUGH WE USE GOOD AVAILABLE
SOFTWARES ( STAAD PRO IS ENOUGH AS FAR AS I KNOWN ) , IT IS BETTER TO CROSS CHECK
MANUALLY OR BY PEPARING IN EXCEL SHEETS

NB. : FOR SUCH TYE OF ANALYSIS BAY SPACING ALSO IMPORTANT, AND TAKE THE CRANE DATA
FROM THE CUSTOMER , ALSO ASK HIS REQUIRMENT IF ANY IN FUTURE ,
AS IT IS NOT RESTING ON STEEL COLUMNS , IT GOING TO REST ON RCC COLUMNS ,
LATER IT IS DIFFICULT TO STRENGTHEN IT.

PLZ DO CONCENTARE TO CALCULATE HORIZONTAL AND VRTL IMPACT FACTORS.


BYE

https://www.sefindia.org/forum/viewtopic.php?p=47490 2/4
4/17/2018 www.sefindia.org :: View topic - Application of Crane Load in Staad

me_onnetwork wrote:
Hi Sefians.

I am analysing an Industrial Building in Staad.pro. Its a Power House structure of a Hydro-


Power Project.

The structure is in Earthquake Zone V. The structure contains steel Roof Truss supported on
RCC Columns. In My first step I have designed the Steel roof truss for wind load. Now, for
designing the beam columns I have applied the earthquake load.
In the Power House there is a 150/25 t EOT Crane.

After applying DL, LL, EL/WL I am stuck in the Crane load part.

Maximum Static AXle Load (From Manufacturer) = 50t / axle

1.Shall I apply a moving Load on the Gantry Girder or shall I apply Point Loads on each column
with a definite Impact factor.

2. How generally Gantry girders and columns supported them are analysed and Designed in
Staad.

3. Which Method can save my time.

Your Suggestions would be of great guidance to me.

Thanks & Regards


Bhawna

Back to top

vikram.jeet Posted: Thu May 17, 2012 7:10 am Post subject: Application of Crane Load in Staad
General Sponsor

When an enemy can be killed with bullet, it is folly to use gun fire /tank fire/air-strike
on him.

For column design , the critical condition is when gantry crane is at the column
bracket . The reactions will be maximum and can be input as point loads in
Joined: 26 Jan 2003 vertical , lateral and longitudinal directions based on vertical load with impact & braking
Posts: 2212 effects .Effect of eccentricity of load from bracket to column cente-rline needs
also to be taken in form of moment.

Using moving loads in staad will give reactions for all positions of gantry on
G/Girder span but critical values for column design are one's at column
locations.

best regds

vikramjeet

Hi Sefians. I am analysing an Industrial Building in Staad.pro. Its a Power House structure of a


Hydro-Power Project. The structure is in Earthquake Zone V. The structure contains steel Roof
Truss supported on RCC Columns. In My first step I have designed the Steel roof truss for wind
load. Now, for designing the beam columns I have applied the earthquake load.
In the Power House there is a 150/25 t EOT Crane. After applying DL, LL, EL/WL I am stuck in the
Crane load part. Maximum Static AXle Load (From Manufacturer) = 50t / axle 1.Shall I apply a
moving Load on the Gantry Girder or shall I apply Point Loads on each column with a definite
Impact factor. 2. How generally Gantry girders and columns supported them are analysed and
Designed in Staad. 3. Which Method can save my time. Your Suggestions would be of great
guidance to me. Thanks & Regards Bhawna
--

Posted via Email

Back to top

me_onnetwork Posted: Fri May 18, 2012 7:45 am Post subject:


SEFI Regulars

Thanks to All for your Valuable Replies.


Joined: 19 Jan 2009
Posts: 20 I am first analysing the Gantry beam and the support reactions is thus obtained. After obtaining
this I am applying this load on Columns in Staad.

Is it the correct method.


Back to top

https://www.sefindia.org/forum/viewtopic.php?p=47490 3/4
4/17/2018 www.sefindia.org :: View topic - Application of Crane Load in Staad

Display posts from previous: All Posts Oldest First Go

All times are GMT


www.sefindia.org Forum Index -> SEFI General Discussion

Page 1 of 1

Jump to: SEFI General Discussion Go


Translate topic Go
You cannot post new topics in this forum
You cannot reply to topics in this forum
You cannot edit your posts in this forum
You cannot delete your posts in this forum
You cannot vote in polls in this forum