Dear Customer,
Thank you for purchasing this Full Colour USB Tester from Hangzhou Ruideng Technologies
Co., Ltd. Prior to using this product we recommended that you briefly familiarize yourself with
these instructions. In order to ensure the correct operation and use of the device. We also advise
that you keep these instructions in a safe place for future reference as may be needed.
The product has a current reset function. When the current display value of the product is
inaccurate, remove the load, press and hold the button, and plug it into the charging head until
the screen lights up and release the button to calibrate the current.

Technical Parameters:
Model: AT34 Display screen:0.96 Inch color IPS display
Voltage measurement range:3.70-30.00V Voltage measurement resolution:0.01V
Current measurement range: 0-4.000A Current measurement resolution: 0.001A
Capacity accumulation range: 0-99999mAh Voltage measurement accuracy:±(0.8%+4digits at 25℃)
Energy accumulation range:0-99999mWh 999.99Wh Current measurement accuracy: ±(1%+4 digits, at 25℃)
Load impedance range: 1Ω-9999.9Ω Power measurement range:0-120W
Temperature range:0℃~80℃/32℉~176℉ Temperature measurement error:± 3℃/ ± 6℉
Working temperature range: 0~45℃ Refresh rate: 2Hz
Dimensions:64mmx22mmx12mm Product weight:14g (package 28g)
Quick charge recognition mode:QC2.0、QC3.0、APPLE 2.4A/2.1A/ 1A/0.5A、Android DCP、SAMSUNG

Function Interface:

Measurement Main Quick Charge Recognition


Interface Interface

Button Instruction:
The button is located on back of the tester. There are 2 kinds operation ways, long press
and short press. Short press is to realize switch between Measurement Main Interface and
1
Hangzhou Ruideng Technologies Co., Ltd

Quick Charge Recognition Interface. Long press is to realize switch of system setting.

Introduction of Icon Function

1: Press and hold the button to choose this icon to


open or close the screen

2: Press and hold the button to choose this icon


to switch the temperature unit.

3: Press and hold the button to choose this icon to switch data group

4: Press and hold the button to choose this icon to clear data group.

5: Press and hold the button to choose this icon rotate the screen

Operation Instruction:
After power on, welcome interface will be displayed firstly,
then main measurement interface will be shown.

Interface 1: Main Measurment Interface.


6:Voltage Measurement
7:Current Measurement
8:Accumulated Capacity
9:Accumulated Energy
10:Temperature Measurement
11:Number of the Data Group in use
12:Load Equivalent Impedance
13:Power Measurement

Press the button on the back to switch to Quick Charge Recognition Interface
Interface 2: Quick Charge Recognition Interface:
14:D +: (DP) data positive signal level.
15:D-: (DM), data negative signal level.
16:Mode display
The product will automatically identify a device with a
2
Hangzhou Ruideng Technologies Co., Ltd

supported fast charging mode. At this time the device supports the QC2.0 、 QC3.0 、 APPLE
2.4A/2.1A/ 1A/0.5A、Android DCP、SAMSUNG.(Note: This quick charge agreement recognition model is
for reference only, because cell phone updated quickly, it can't be absolutely accurate identification)

Parameter Setting:
At any interface of 2 interfaces, Press and hold the button to realize data set. Long press the
button more than 0.5s, the corresponding icon will be selected and displayed (the background of
icon turns black to blue), then step through the options of screen off, temperature display units,
data group switch, data group clear zero and screen rotation. Stop on the function you wish to set
then loosen the button

Press and hold the button, the corresponding icon will be selected and displayed, then

loosen the button, screen will be off, then press the button or power on again, the display will
light again

. Press and hold the button, the corresponding icon will be selected and displayed, then

loosen the button, the temperature unit will be switched. Degree centigrade is the default
temperature unit

Press and hold the button, the corresponding icon will be selected and displayed, then

loosen the button, data group will be switched. This tester can provide 2 groups to store and
check, 0 and 1 data group. When the data set is 0 group, the current capacity will be stored
after power off. When power on next time, the stored mAh and mWh is blinking displayed.
When the new mAh is up to 1 mAh, the stored mAh and mWh will be covered, and the values
will start over. When data set is group 1, the current capacity will be stored after power off. And
the stored capacity will be accumulated after power on.

Press and hold the button, the corresponding icon will be selected and displayed, then

loosen the button, the data of the current data group will be zero.

Press and hold the button, the corresponding icon will be selected and displayed, then

loosen the button, the screen will be rotated 180 degree, and stored automatically, which is
convenient for later using

3
HangZhou RuiDeng Technologies Co., Ltd

Appendix 1: Explanation of terms


Quick charge: fast charging, modern fast charging mostly refers to the charging process
when the charging current is greater than 2A or the charging power is greater than 10W.
Quick Charge Protocol Detection: Detect which quick charge protocols are supported by
the charger.
Quick Charge Protocol/Quick Charge Mode Recognition: Identify what fast quick is
currently in progress.
Decoy/trigger: Simulates a quick charge protocol sequence that allows the charger to
output high voltage/high current.
Quick Charge Simulation: Analog protocols which chargers do not support to improve
charger compatibility.
Common part of the quick charge agreement:
Qualcomm: QC2.0, QC3.0, QC4+
Media Tek: PE2.0, PE3.0
Huawei: FCP SCP
OPPO: VOOC, Super VOOC
One plus: DASH, Warp
USB Type-C: PD2.0, PD3.0, PPS
mAh, mWh: milliampere hour, milliwatt hour, milliampere is the capacity unit. Milliwatt hours is
the unit of energy.

Appendix 2: Basic Operational Knowledge

I: measure the capacity of power bank


Preparation materials: power bank to be tested, USB tester, HD35 electric load or mobile
phone, charging head.
the data need to view: the capacity energy value of the power bank (mAh mWh), the
voltage and current value of the power bank output
First charge the power bank, then adjust the current meter to the non-zero data group,
then use the power bank to charge the mobile phone or use the HD35 electronic load to
discharge to the power bank to automatically shut down, use the charging head to supply
power to the tester, and then Record the mAh, mWh values on the tester.
Method 1: The comparison tester shows that the mWh is divided by efficiency (like 90%)
and the power bank mWh. If the difference is not large, the capacity of power bank is real (the
most accurate method).
Method 2: If the mobile phone is 5V charging, the tester displays mAh multiplied by 1.5. If
the mobile phone is a 9v charging tester, the mAh multiplied by 2.7. If the value is not much
different from the technical parameter of power bank. The power bank’s capacity is real. (only
applicable to power bank without mWh).
Since many mobile power sources are currently tens of thousands of mAh, if you simply
charge the mobile phone to measure the capacity of the power bank. You need to charge the
4
HangZhou RuiDeng Technologies Co., Ltd

mobile phone many times. It takes even a week to measure the capacity of power bank, in
order to quickly discharge the power of the power bank. Test with a constant current load. Take
xiaomi power bankII as an example, it can support 5V/2A output, 38.5Wh/(5V*2A)=3.85. It can
discharge the power of power bank in about 4 hours. If you use HD35 electronic load, it can be
triggered 9V. Thus 18W quick discharge, 38.5Wh / (9V * 2A) = 2.13h, so that it takes only two
hours to complete the power bank capacity test, quickly identify whether the capacity of power
bank is false (high power discharge, inversion rate will decrease and the actual measured
capacity will be smaller).

II. Measuring the quality of data cable


The quality of the data cable directly affects the speed of charging, even worse the inferior
data cable has the risk of burning the phone, so measuring the quality of the data cable is also
a necessary function. We have two ways to measure the quality of the data cables, each with
its own advantages and disadvantages, you can choose the better way which suits you .
The common data cable length has a great influence on the actual test results. Generally
speaking, the shorter cable ‘s performance should be better.
1. Current measurement method:
Test materials: mobile phone, original charger, original data cable, USB tester, data cable to
be tested.
Test procedure: Discharge the phone to between 50% and 60% power. Use the original
charger, USB tester and original data cable to measure the charging current and record this
current. Then replace the original data cable with the data cable to be tested, and record the
charging current again. The time between the two measurements should not be too long. The
higher the charging current, the better the quality of the line. If the charging current values
differ a lot, it may indicate that the quality of the cable is very bad or the mobile phone is not
supported to the cable(Note: you must use UM25 to test Huawei Super Quick Charge).
2.Cable resistance measurement method:
Test materials: charger, UM series tester, constant current load (such as HD35), data cable
to be tested.
Test procedure: Insert the tester into the charger,switch to the line resistance measurement
interface, plug in the load, adjust the current to about 1A, hold the button and wait for the tester
to flash, then remove the tester.
Connect the data cable. Plug it into the charger, plug the other end of the data cable into the
tester input, turn on the load, and hold the button. The resistance of this cable will be displayed
on the tester.
Advantages of current measurement method: It can intuitively judge whether the data cable
supports the fast charge and fast charge current value, and you only need to buy a USB tester.
Disadvantages of current measurement method: relying on mobile phones and original
accessories of the phone as a comparison.
Advantages of line resistance measurement: It is possible to measure the actual parameters
for comparison between different wires. Generally, the micro data line resistance will be above
400mΩ, and the Type-C data line can be made smaller. No need to use a mobile phone for
measurements
Disadvantages of line resistance measurement: the tester and load are required to measure,

5
HangZhou RuiDeng Technologies Co., Ltd

and the price is higher.

You might also like