Maximum Total Uniform Load, Kips: Table 3-9 (Continued)

This table provides the maximum total uniform load for various MC-shaped steel beams with a yield strength of 36 ksi. It lists the maximum load in kips for different beam sizes and spans ranging from 2 to 20 feet. Additional properties are also provided for each beam size, including weak-axis bending capacity, strong-axis bending capacity, and available shear strength. The table is limited by the available shear strength for beams without lateral bracing support.

Uploaded by

rondana1
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
349 views1 page

Maximum Total Uniform Load, Kips: Table 3-9 (Continued)

This table provides the maximum total uniform load for various MC-shaped steel beams with a yield strength of 36 ksi. It lists the maximum load in kips for different beam sizes and spans ranging from 2 to 20 feet. Additional properties are also provided for each beam size, including weak-axis bending capacity, strong-axis bending capacity, and available shear strength. The table is limited by the available shear strength for beams without lateral bracing support.

Uploaded by

rondana1
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

AISC_Part 3B:14th Ed.

2/24/11 8:54 AM Page 95

MAXIMUM TOTAL UNIFORM LOAD TABLES 3–95

Table 3-9 (continued)


Maximum Total
Fy = 36 ksi
Uniform Load, kips
MC-Shapes MC8-MC7

MC8× MC7×
Shape
22.8 21.4 20 18.7 8.5 22.7
Design ASD LRFD ASD LRFD ASD LRFD ASD LRFD ASD LRFD ASD LRFD
2 82.8 124 37.0 55.7 91.1 137
3 88.4 133 77.6 117 78.6 118 73.1 110 33.3 50.0 78.6 118
4 68.6 103 65.4 98.3 58.9 88.6 56.0 84.2 25.0 37.5 58.9 88.6
5 54.9 82.5 52.3 78.6 47.1 70.8 44.8 67.4 20.0 30.0 47.1 70.8
6 45.7 68.8 43.6 65.5 39.3 59.0 37.4 56.2 16.6 25.0 39.3 59.0
7 39.2 58.9 37.4 56.2 33.7 50.6 32.0 48.1 14.3 21.4 33.7 50.6
8 34.3 51.6 32.7 49.1 29.5 44.3 28.0 42.1 12.5 18.8 29.5 44.3
9 30.5 45.8 29.1 43.7 26.2 39.4 24.9 37.4 11.1 16.7 26.2 39.4
10 27.4 41.3 26.2 39.3 23.6 35.4 22.4 33.7 9.99 15.0 23.6 35.4
11 25.0 37.5 23.8 35.7 21.4 32.2 20.4 30.6 9.08 13.6 21.4 32.2
12 22.9 34.4 21.8 32.8 19.6 29.5 18.7 28.1 8.32 12.5 19.6 29.5
13 21.1 31.7 20.1 30.2 18.1 27.2 17.2 25.9 7.68 11.5 18.1 27.2
14 19.6 29.5 18.7 28.1 16.8 25.3 16.0 24.1 7.13 10.7 16.8 25.3
15 18.3 27.5 17.4 26.2 15.7 23.6 14.9 22.5 6.66 10.0 15.7 23.6
Span, ft

16 17.2 25.8 16.3 24.6 14.7 22.1 14.0 21.1 6.24 9.38 14.7 22.1
17 16.1 24.3 15.4 23.1 13.9 20.8 13.2 19.8 5.88 8.83 13.9 20.8
18 15.2 22.9 14.5 21.8 13.1 19.7 12.5 18.7 5.55 8.34
19 14.4 21.7 13.8 20.7 12.4 18.6 11.8 17.7 5.26 7.90
20 13.7 20.6 13.1 19.7 11.8 17.7 11.2 16.8 4.99 7.51

Beam Properties
Wc /Ωb φbWc , kip-ft 274 413 262 393 236 354 224 337 99.9 150 236 354
Mp /Ωb φb Mp , kip-ft 34.3 51.6 32.7 49.1 29.5 44.3 28.0 42.1 12.5 18.8 29.5 44.3
Mr /Ωb φb Mr , kip-ft 20.0 30.1 19.4 29.1 17.1 25.7 16.5 24.8 7.32 11.0 17.0 25.5
BF /Ωb φb BF, kips 0.724 1.09 0.733 1.10 0.775 1.16 0.778 1.17 0.970 1.46 0.493 0.741
Vn /Ωv φvVn , kips 44.2 66.4 38.8 58.3 41.4 62.2 36.5 54.9 18.5 27.8 45.5 68.4
Zx , in.3 19.1 18.2 16.4 15.6 6.95 16.4
Lp , ft 4.25 4.25 3.61 3.61 2.08 4.33
Lr , ft 24.0 22.4 19.6 18.4 7.42 29.7
ASD LRFD Note: For beams laterally unsupported, see Table 3-11.
Available strength tabulated above heavy line is limited by available shear strength.
Ωb = 1.67 φ b = 0.90
Ωv = 1.67 φ v = 0.90