Alignment of Steam Turbine
Alignment of Steam Turbine
COUPLING ALIGNMENT
DIAL INDICATOR A
B
''D''
TURBINE
R/G SIDE
SIDE
''C''
PULL TURBINE
Turbine
Side Offset ''E'' Center
PARALLEL ANGULAR
1
Allowable Values
A (Angular alignment) : Less than 10/100mm
B (Parallel alignment) : Less than 10/100mm
''C'' : Within 450 +0.5 / +0.2mm
''D'' : 0.19mm
''E'' : 0.14mm
Remarks
1. This measurement shall be performed after pulling out the turbine rotor to gear side.
2. Refer to Flexible Coupling Drawing.
2
2.COUPLING ALIGNMET BETWEEN REDUCTION GEAR AND GENERATOR
A DIAL INDICATOR
''D''
GENERATOR
SIDE
''C''
R/G
SIDE
Generator
Side Offset ''E''
Center
PARALLEL ANGULAR
3
Allowable Values
A (Angular alignment) : Less than 10/100mm
B (Parallel alignment) : Less than 10/100mm
''C'' : Within 550 +1.0 / +0.5mm
''D'' : 0.06mm
''E'' : 0.09mm
Remarks
1. This measurement shall be performed after rotating the wheel shaft by means.
2. Refer to Flexible Coupling
4
ALIGNMENT CALCULATIONS
When execute the alignment procedures you take readings of dial indicator on 12,3,6
and 9 positions but the values must be as above, therefore the readings of dial
indicator shall be satisfactory these values.
The readings of dial indicator called designed value as write it NDPS experience but
we can not know how them calculate after analysis by mathematic methods we note
that as follow:
-(D+E) R -(D-E)
-2D