GH Series section
Motor Controls
• Click on part #s
to link directly to
our online store for
current pricing, specs,
stocking information
and more
Cutler-Hammer
Motor Controls
Motor Controls
Bryant
Manual Motor Controls
Available
the Uin
.S o
nly
,i
fo
rde
red
by
6p
m
ET.,
add
ition ly.
al sh ipping charges may app
Motor Monitor
Relays
Volume 13
w w w . a u t o m a t i o n d i r e c t . c o m / m o t o r- c o n t r o l s e17-1
Fuji Electric IEC Motor Controls
AUTOMATIONDIRECT has cooperated with Fuji Electric to offer a The Odyssey Series of contactors and overload relays also
complete line of IEC electric motor controls. features the SUPERMAGNET™ coil and come in sizes up to 361
The DUO line (SC-E contactors and TK-E overloads) is fully inte- A, AC-3 operation (300 horsepower at 480 VAC). Odyssey Series
grated so multiple motor speed controller solutions are possible contactors are available in four sizes with overload relays to match
with a minimum number of components. The conventional motor any motor to 300 horsepower.
starters in the DUO line can accommodate electric motors up to Now available: 380-450 VAC and 460-575 VAC Coil Voltages
100 horsepower at 480VAC. The larger motor contactors feature Both the DUO and Odyssey lines are available in 24 VAC, 24
the SUPERMAGNET™ coil for greater reliability and positive pick- VDC, 120 VAC, 240 VAC, 380-575 VAC. The motor contactors
up and drop-out. are rated up to 690 VAC, 3-phase.
Now available: 440-480 VAC and 500-550 VAC Coil Voltages
DUO Series: SC-E series contactors and TK-E series overload relays
SC-E Series Contactor Features
1/2 to 100 hp
9 - 150A (AC3) rated current
• 5 to 100 hp at 480 VAC
• cULus and CSA approval, CE mark, meets JIS and
IEC standards.
• Models SC-E02-xxx to SC-E4-xxx have3-pole main
circuits and come in threesizes with widths of 43
mm, 54 mm, and67 mm.
• Models SC-E1-xxx to SC-E7-xxx employ a box
terminal structure; allowing wires to be connected
directly to the main circuit.
• Has a finger-protection terminal structure that pre-
vents the exposure of live parts.
• Models SC-E5-xxx to SC-E7-xxx use a SUPERMAG-
NETTM (AC-input/DC-output operation) for high
operating reliability
Traditional starters
Fuji’s DUO line offers a complete range of com-
ponents for building a traditional starter utilizing
overload relays, auxiliary and alarm contacts, and
mechanical interlocks to create a reversing unit.
Volume 13
Motor
Controls
• Overload, phase loss
protection
• Isolated NO and Proximity
NC contacts Sensors
• Ambient temperature
Photo
Sensors
compensation
• Trip indicator Terminal Covers
Limit
• Finger protection
terminals Switches
• IEC-947, UL, CSA, CE
(MMS)
Current
Sensors
Use Odyssey
components to
Circuit breakers for motor use that build a traditional Pressure
Sensors
provide optimal protection by inte- starter
grating the functions of a molded Temperature
Combination
Replacement Coils
Sensors
case circuit breaker and thermal
Starters
overload relay into a compact unit. Pushbuttons/
Lights
BM3 Series
The ability to configure combi- Process
- Rated Current: 0.16 to 32A, 10 to 63A nation starters for compact,
Relays/
- Short Circuit Current Rating: 100 kA at 240V, 50 kA reliable motor protection by Timers
at 480V, 10 kA at 600V combining a manual motor
- Widths: 45 mm and 55 mm starter and a magnetic Comm.
contactor.
Surge suppressors
Terminal
Blocks &
Wiring
CHECK OUT OUR PRICES
AutomationDirect Allen-Bradley GE ABB Power
Motor Controls
Circuit
Fuji
Protection
9 Amp Contactor $13.75 $90.00 * $110.60 $69.58 *
Enclosures
SC-E02-110VAC 100-C09D10 CL00A310TJ A9-30-10-84
and more!
Tools
40 Amp Contactor $48.75 $202.00 $257.25 $264.92 *
SC-E2-110VAC 100-C37D00 CL06A311MJ A40-30-10-84
Pneumatics
10 Amp $49.00 $207.00 $100.4 $171.03
Appendix
Motor Starter BM3RHB-010 140M-C2E-C10 MS325-12.5
Product
* This product includes 1 N.0. Aux contact
All prices are U.S. published prices. AutomationDirect prices are from March 2011 Price List. Allen-Bradley prices taken from www.rockwellautomation.com/en/e-tools 2/21/11 GE prices taken from Index
www.grainger.com 2/22/11. . ABB prices taken from www.galco.com 2/22/11. Prices and specifications may vary by dealer and configuration. Prices subject to change without notice.
Part #
Index
Volume 13
Odyssey Series
3N Contactor BZ0BP base plate
See page 17-43
3N Contactor
See page 17-52
See page 17-52
3N Overload relay
• 60 to 300 hp • 1/2 to 40 hp @ 480 V
See page 17-55
• 180-361 A (AC3)
• 60 to 300 hp
Volume 13
Systems
Features Overview
• SC-E02-xxx to E05-xxx: 43mm wide • Low power consumption Optional accessories Motor
• SC-E1-xxx to E2S-xxx: 54mm wide • Recycled thermoplastic resin used for • Auxiliary contact blocks
Controls
• SC-E3-xxx, E4-xxx: 67mm wide plastic parts. • Coil surge suppression units Proximity
• SC-E5-xxx: 88mm wide • The names of materials are indicated on • Replacement coils for contactor sizes Sensors
all major parts to facilitate recycling SC-E5 and larger
Photo
SC-E Series Contactors Specifications - UL and CSA Sensors
Rated Insulation
Thermal Current
Switches
SCCR Ratings
Nominal Coil
Frame Width
1-Phase
Rated AC-3
Rated AC-1
Voltage (V)
Model Price 3-Phase Motor Motor Encoders
(A) [note 2]
Voltage
(mm)
Current
(KA)
Sensors
240V 480V 600V 120V 240V
SC-E02-24VAC <---> 24VAC Pressure
Sensors
SC-E02-110VAC <---> 110VAC
SC-E02-220VAC <---> 220VAC Temperature
2 2 5 5 1/3 1 9 20 Sensors
SC-E02-440VAC <---> 440-480VAC
SC-E02-500VAC <---> 500-550VAC Pushbuttons/
Lights
SC-E02G-24VDC <---> 24VDC
SC-E03-24VAC <---> 24VAC Process
Volume 13
Rated Insulation
Thermal Current
SCCR Ratings
Nominal Coil
Frame Width
1-Phase
Rated AC-3
Rated AC-1
Voltage (V)
Model Price 3-Phase Motor Motor
(A) [note 2]
Voltage
200V 220– 400– 550– 100– 220–
(mm)
(KA)
240V 480V 600V 120V 240V
SC-E1-24VAC <---> 24VAC
SC-E1-110VAC <---> 110VAC
SC-E1-220VAC <---> 220VAC
7.5 10 25 25 2 3 32 50
SC-E1-440VAC <---> 440-480VAC
SC-E1-500VAC <---> 500-550VAC
SC-E1G-24VDC <---> 24VDC
SC-E2-24VAC <---> 24VAC
SC-E2-110VAC <---> 110VAC
SC-E2-220VAC <---> 220VAC
10 15 30 30 3 5 40 60 54
SC-E2-440VAC <---> 440-480VAC
SC-E2-500VAC <---> 500-550VAC
SC-E2G-24VDC <---> 24VDC
SC-E2S-24VAC <---> 24VAC
SC-E2S-110VAC <---> 110VAC
SC-E2S-220VAC <---> 220VAC
15 20 30 30 3 10 50 65 5
SC-E2S-440VAC <---> 440-480VAC
SC-E2S-500VAC <---> 500-550VAC
SC-E2SG-24VDC <---> 24VDC
SC-E3-24VAC <---> 24VAC
SC-E3-110VAC <---> 110VAC
SC-E3-220VAC <---> 220VAC
20 25 50 50 5 15 65 100
SC-E3-440VAC <---> 440-480VAC
SC-E3-500VAC <---> 500-550VAC 690
SC-E3G-24VDC <---> 24VDC
67
SC-E4-24VAC <---> 24VAC
SC-E4-110VAC <---> 110VAC
SC-E4-220VAC <---> 220VAC
25 30 50 50 5 15 80 105
SC-E4-440VAC <---> 440-480VAC
SC-E4-500VAC <---> 500-550VAC
SC-E4G-24VDC <---> 24VDC
SC-E5-24V <---> 24VAC/VDC
SC-E5-100V <---> 110VAC/VDC
SC-E5-200V <---> 220VAC/VDC 30 30 60 75 7.5 15 105 150 88
SC-E5-400V <---> 380-450VAC
SC-E5-500V <---> 460-575VAC
SC-E6-24V <---> 24VAC/VDC
SC-E6-100V <---> 110VAC/VDC
SC-E6-200V <---> 220VAC/VDC 40 40 75 100 10 20 125 150 10 100
SC-E6-400V <---> 380-450VAC
SC-E6-500V <---> 460-575VAC
SC-E7-24V <---> 24VAC/VDC
SC-E7-100V <---> 110VAC/VDC
SC-E7-200V <---> 220VAC/VDC 50 50 100 125 15 25 150 200 115
SC-E7-400V <---> 380-450VAC
SC-E7-500V <---> 460-575VAC
Notes: 1. AC3 type loads consist of squirrel cage three-phase motors; occasional, limited jogging duty.
2. AC1 non-inductive or slightly inductive loads. Typically resistive loads (i.e. furnaces, ovens, etc.)
Volume 13
Systems
Overview
Programmable
SC-E Series Contactors Specifications - IEC Controllers
SC-E7-xxx 45 / 45 75 / 75 75 / NA 90 / NA 150 / 150 150 / 150 120 / NA 103 / NA 200 200 200 2NO+2NC Photo
Sensors
Limit
Switches
Current
Internal Auxiliary Contact Ratings - UL and CSA Sensors
Relays/
Internal Auxiliary Contact Ratings - IEC, JIS Timers
Pneumatics
Appendix
Product
Index
Part #
Index
Volume 13
Frame Size Inrush Sealed Pick-Up Voltage (V) Drop-Out Voltage (V)
50Hz 60Hz Coil ON to Coil OFF to
Contact ON Contact OFF
50/60Hz 50/60Hz
E02 to E05-xxx 90/95 9/9 2.7 2.8 0.85 - 1.1 x U.S. 0.2 - 0.75 x U.S. 9-20 5-16
rated coil voltage rated coil voltage
E1 to E2S-xxx 120/135 12.7/12.4 3.6 3.8 0.85 - 1.1 x U.S. 0.2 - 0.75 x U.S. 10-17 6-13
rated coil voltage rated coil voltage
E3, E4-xxx 180/190 13.3/13.4 4.5 5 0.85 - 1.1 x U.S. 0.2 - 0.75 x U.S. 10-18 8-18
rated coil voltage rated coil voltage
E5-xxx 80/95 4/4.6 3.2 3.6 0.85 - 1.1 x U.S. 0.2 - 0.75 x U.S. 39-45 27-33
rated coil voltage rated coil voltage
E6, E7-xxx 190/230 4.9/5.8 3.4 3.7 0.8 - 1.1 x U.S. 0.1 - 0.65 x U.S. 31-37 30-36
rated coil voltage rated coil voltage
DC Coil Characteristics
Power Consumption (W) Operating Time (ms)
E02G to E05G-xxx 7 7 0.85 - 1.1 x U.S. 0.1 - 0.75 x U.S. 45-49 10-26
rated coil voltage rated coil voltage
E1G to E2SG-xxx 9 9 0.85 - 1.1 x U.S. 0.1 - 0.75 x U.S. 40-50 8-17
rated coil voltage rated coil voltage
E3G, E4G-xxx 12 12 0.85 - 1.1 x U.S. 0.1 - 0.75 x U.S. 60-70 14-21
rated coil voltage rated coil voltage
E5-xxx 20 2.8 0.85 - 1.1 x U.S. 0.1 - 0.75 x U.S. 35-41 26-32
rated coil voltage rated coil voltage
E6, E7-xxx 225 3.2 0.8 - 1.1 x U.S. 0.1 - 0.65 x U.S. 28-34 27-33
rated coil voltage rated coil voltage
Free on orders
over $300
1-800-633-0405 www.automationdirect.com
Fuji Duo Series SC-E Contactors
Standard operating Standard Operating Conditions
conditions Ambient
Operating: -5 to 55°C
No sudden temperature changes resulting in condensation or icing
The magnetic contactors are manufac- Temperature (The average temperature over a 24-hour period must not exceed 35°C)
Storage: -40 to 65°C
tured for use in the standard operating
conditions given in the table. Humidity 45 to 85%RH
Altitude 2000m or lower
Atmosphere No excessive dust, smoke, corrosive gases, flammable gases, steam, or salt
Mounting Angle
˚ 30 ˚ 30
30 ˚ 30 ˚
IEC 947-4-1, EN 60947-4-1, VDE 0660
Standard JIS C 8201-4-1, JEM 1038
UL 508, file E42419; CSA C22.2, file 20479
Volume 13
Systems
Overview
Contactor Type SC-E1, E2, E2S-xxx SC-E3, E4-xxx SC-E5, E6-xxx SC-E7-xxx Software
Power
Circuit
Protection
Enclosures
Tools
Pneumatics
Appendix
Product
Index
Part #
Index
Volume 13
SC-E05
SC-E02
SC-E03
SC-E04
200 - 240V 380 - 440V
10000
10000
5000
5000
Make/break operations ( 103)
3000
3000 2000
2000
1000
1000
500
500
300
300 200
200
100
100
50
50
30
30 20
20
10
10 1 2 3 5 10 20 30 50 100 200 300 500 1000
12A
18A
25A
9A
7.5kW
11kW
380 - 440V
2.2kW
5.5kW
3kW
4kW
200 - 240V
SC-E2
SC-E6
SC-E7
SC-E4
5000 5000
Make/break operations ( 103)
3000 3000
2000 2000
1000 1000
500 500
300 300
200 200
100 100
50 50
30 30
20 20
10 10
10 20 30 50 100 200 300 500 1000 2000 3000 5000 10000
105A
125A
60kW 150A
32A
40A
50A
65A
40kW 80A
55kW
30kW
75kW
18.5kW
380 - 440V
7.5kW
22kW
30kW
37kW
18.5kW
45kW
11kW
15kW
200 - 240V
SC-E03
SC-E04
SC-E05
SC-E1
SC-E2
SC-E6
SC-E7
SC-E4
5000
Make/break operations ( 103)
5000
3000
3000
2000
2000
1000
1000
500
500
300
300
200
200
100
100 1 2 3 5 10 20 30 50 100 200 300 500 1000
25A
200A
65A
20A
32A
60A
100A
150A
50A
105A
Volume 13
Systems
Overview
Programmable
Controllers
Optional accessories
Field I/O
Software
SC-E Contactor
SZ-Z coil surge
C-more &
SZ-AS1T auxiliary suppression unit other HMI
contact block
Drives
SZ-AS1T auxiliary
Soft
contact block Starters
Motors &
Gearbox
Steppers/
Servos
Motor
Controls
Proximity
Sensors
Photo
Sensors
Current
Sensors
Pressure
Sensors
Auxiliary contact blocks with
Temperature
terminal covers Sensors
Volume 13
Systems
Overview
Connection kits for reversing SC-E contactors
Programmable
Controllers
Field I/O
Software
Motors &
Gearbox
Steppers/
Servos
Motor
Controls
Proximity
SZ-ERW2D SZ-ERW3A SZ-ERW3B SZ-ERW3D Sensors
Photo
Load Side Line Side Sensors
Load Side Load Side
Wiring Wiring
Wiring Wiring Limit
Switches
Encoders
Connection Kits
Current
Sensors
Part Number Price Description Use with Contactors
SZ-ERW1A <---> Line side reversing connection kit. Pressure
Sensors
SZ-ERW1B* <---> Load side reversing connection kit. For wiring load side when using contactors only or with a MMS device. SC-E02-xxx to SC-E05-xxx
Temperature
SZ-ERW1D <---> Load side reversing connection kit. For wiring load side when using two contactors with a thermal overload relay. Sensors
SZ-ERW2A <---> Line side reversing connection kit.
Pushbuttons/
SZ-ERW2B* <---> Load side reversing connection kit. For wiring load side when using contactors only or with a MMS device. SC-E1-xxx to SC-E2S-xxx Lights
SZ-ERW2D <---> Load side reversing connection kit. For wiring load side when using two contactors with a thermal overload relay. Process
SZ-ERW3D <---> Load side reversing connection kit. For wiring load side when using two contactors with a thermal overload relay. Comm.
* When using the SZ-ERWxB, a TK-E thermal overload relay must be separately mounted and wired using an SZ-HxE
Terminal
base. To assemble a TK-E overload directly to the contactor use a SZ-ERWxD load side connection kit. Blocks &
Wiring
SZ-RM <---> Used when building a reversing starter. Prevents both contactors from SC-E02-xxx to SC-E4-xxx
being pulled in at once. Tools
Pneumatics
SZ-RM NOTE: Mechanical interlock unit cannot be used with SC-E5-xxx through E7-xxx contactors.
Appendix
Parts for reversing Fuji SC-E contactors
• SC-E (Contactors - qty. 2) Product
Index
• SZ-ERWxA (Line side connection kit - qty. 1)
• SZ-ERWxB* (Load side connection kit - qty. 1) Part #
• SZ-RM (Mechanical interlock - qty. 1) Index
18.5(to 20.5)
91(Rail height 15)
2 1
81 (28) * Main (68) * Coil terminal
14.5
8.5
61 terminal M4 43 M3.5 34 SC-E02 to E05-xxx
SC-E1 to E4-xxx
20
SC-E02G to E05G-xxx
1
SC-E1G to E4G-xxx
(48 to)52
SC-E2S, E2SG-xxx
49
60
80
2
*1
*1 *1
53 61 1/L1 3/L2 5/L3 83 71
*2 13 10.5 Mounting hole A1 A2
35
Weight: 0.33 kg 2-M4
Mass: 0.33kg
Use the two mounting holes on a diagonal line
or to mount contactor
: 35 60 : 35 (48 to) 52 54 62 2/T1 4/T2 6/T3 84 72
*1 *1
53 61 13 21 1/L1 3/L2 5/L3 43 31 83 71
90
2
57
A1 A2
80
75
1
*1
54 62 14 22 2/T1 4/T2 6/T3 44 32 84 72
2
Mounting hole
* 16.5 2-M4 45
Weight: *1 In case of aux. contact 4NO+4NC
Mass : 0.58 kg
0.58kg
Use the two mounting holes on a diagonal line
or to mount contactor
: 45 75 : 45 (38 to 46) 80
SC-E3, E4-xxx
Panel drilling
121 (Rail height 15) (28) *2
111
72.5 Main (91) *1 Coil terminal (54 to)60
terminal M3.5
10.5 2.5 67
13
19.5
2
112
90
77
*1
*2 Mounting hole (55 to)60
20.5 2-M4
Weight: 1.1 kg
Mass: 1.1kg
Use the two mounting holes on a diagonal line
or to mount contactor
: (55 to) 60 90 : (54 to) 60 90
Volume 13
Systems
Overview
Programmable
Dimensions (mm) Controllers
SC-E5-xxx
Main Coil terminal Panel drilling Software
132
terminal 1 M3.5
77 (111) *
13.5
32.7 4 88 70 C-more &
Auxiliary
terminal other HMI
M3.5
Drives
129
155
Soft
75
Starters
Motors &
Gearbox
32 Mounting hole
Weight: 2.0 kg
Mass: 2.0kg
2-M4 Steppers/
Servos
1
* Side mounting aux. contact block
*2 Front mounting aux. contact block Motor
Controls
SC-E6-xxx Proximity
Main Coil terminal Panel drilling Sensors
138 terminal M3.5
77 (123) *1
13.5
110
Encoders
Current
Sensors
32 Mounting hole
Weight: 2.6 kg 2-M5 Pressure
Mass: 2.6kg Sensors
Temperature
SC-E7-xxx Sensors
Main Coil terminal Panel drilling
140 M3.5
76.8 terminal (138) *1 Pushbuttons/
14.5
Timers
175
Comm.
Terminal
Blocks &
Mounting hole Wiring
35
Weight: 2.9 kg 2-M5
Mass: 2.9kg
Power
88 M4 43 M3.5 Enclosures
8.5 34
20
Tools
1
(48 to)52
Pneumatics
49
80
60
2 Appendix
*1
Product
Mounting hole
*2 13 10.5 Index
2-M4 35
Weight: 0.59 kg
Mass: 0.59kg Part #
Use the two mounting holes on a diagonal line Index
or to mount contactor
35 60 : 35 (48 to) 52
Volume 13
9.5
10.5 2
5
18.5
2
90
57
75
80
*1 1
Mounting hole
*2 16.5 45
Weight: 0.79 kg 2-M4
Mass: 0.79kg
Use the two mounting holes on a diagonal line
*1 Side mounting aux. contact block or to mount contactor
*2 Front mounting aux. contact block : 45 75 : 45 (38 to 46) 80
SC-E3G, E4G-xxx
140 (Rail height 15) (28) *2 Panel drilling
130
Main Coil terminal (54 to)60
91.5 (91) * 1
M3.5
terminal
10.5 2.5 67
13
19.5
2
112
77
90
1
*1
*2
20.5 Mounting hole (55 to)60
Weight: 1.4 kg
Mass: 1.4kg *1 Side mounting aux. contact block 2-M4
*2 Front mounting aux. contact block
Use the two mounting holes on a diagonal line
or to mount contactor
: (55 to) 60 90 : (54 to) 60 90
1NO+1NC
B
B
28
49
49
28
54 62
11 Approx 10 10
5 25 3 43 24
53 61 71 83
A22T Mass: 36g
Weight: 36 g 2NO+2NC
SZ-A20T , A11T Weight:
Mass: 20 g
20g
54 62 72 84
Type A B C
SC-E02, E03, E04, E05-xxx 43 80 109
SC-E1, E2, E2S-xxx 54 90 124
SC-E3, E4-xxx 67 112 139
SC-E02G, E03G, E04G, E05(G)-xxx 43 80 136
SC-E1G, E2G, E2SG-xxx 54 90 149.5
SC-E3G, E4G-xxx 67 112 158
Volume 13
Systems
Overview
Programmable
Dimensions (mm) Wiring diagrams
Controllers
Contactor with aux. contact block Mounted on right side C-more &
C A 71 83 other HMI
M3.5 12 D 12
Drives
72 84
Soft
Starters
59.5
43
28
B
Mounted on left side Motors &
Gearbox
45 7.7 53 61
12 7.5 Steppers/
Servos
Weight: 28 g
Mass: 28g Type A B C D 54 62
SC-E02, E03, E04, E05-xxx 67 80 81 43 Motor
SC-E1, E2, E2S-xxx 78 90 Controls
54 54
SC-E3, E4-xxx 91 112 67 67
Proximity
SC-E02G, E03G, E04G, E05(G)-xxx 67 80 108 43 Sensors
SC-E1G, E2G, E2SG-xxx 78 90 121.5 54
SC-E3G, E4G-xxx 91 112 130 67 Photo
Sensors
Limit
Switches
SZ-AS2T for SC-E5 to E7-xxx
Encoders
Contactor with aux. contact block
C A 1 N.O. + 1 N.C. Current
12 12 Sensors
D
Mounted on right side
71 83 Pressure
Sensors
M3.5
72 84 Temperature
Sensors
64.5
Pushbuttons/
53 61 Lights
7.7 Process
47.5 12 7 54 62
Relays/
Timers
Weight: 40 g
Mass: 40g
Type A B C D Comm.
SC-E5-xxx 112 155 132 88
Terminal
SC-E6-xxx 124 169 138 100 Blocks &
Wiring
SC-E7-xxx 139 175 140 115
Power
Circuit
Protection
Enclosures
Tools
Pneumatics
Appendix
Product
Index
Part #
Index
Volume 13
15
Weight: 14 g
Mass: 14g
SC-E02 to E05-xxx + SZ-Z4, Z5
(Built-in capacitor/resistor)
C
R
37 (Built-in varistor)
30
C
R
Volume 13
Systems
Overview
Programmable
TK-E series thermal Controllers
C-more &
Features other HMI
• This relay protects motor windings from
Drives
burning due to overloads, locked rotor cur-
rent, or open-phases TK-E02-900 Soft
• Maintenance and inspection safety has TK-E3-5000 Starters
Volume 13
+ =
SC-E Contactor TK-E Overload Relay
Step 1. Select a contactor from page 17-5 based on motor voltage and horsepower.
Step 2. Select an overload relay from page 17-21 based on motor full load current.
Check the data plate on the motor for the hp, volts and full-rated amps.
Motor
Volume 13
Programmable
220-240V 3-Phase Motor (0.5 to 50 hp)1 Controllers
Note 1: For 220-240 V three-phase motors up to 150 hp refer to the Fuji Odyssey series. Encoders
Note 2: Per NEC 2005 table 430.250
Current
Sensors
Volume 13
Specifications
Trip No. of Power
Applicable Contactor Auxilliary
Model Contact Class IEC Heater Consumption Features
Non-reversing 60947-4-1 Elements per Pole (VA)
TK-E02-xxx SC-E02, E03, E04, E05-xxx 2.2
Overload, open-phase protection,
TK-E2-xxx SC-E1, E2, E2S-xxx 3.8
Ambient temperature compensation,
TK-E3-xxx SC-E3, E4-xxx 1NO+1NC 10A 3 6.6 Manual/auto reset selectable,
Manual trip mechanism,
TK-E5-xxx SC-E5-xxx 6.6 Trip indicator
TK-E6-xxx SC-E6, E7-xxx 8.0
Volume 13
Systems
Overview
Wiring Programmable
Controllers
Photo
Wire Sizes, Tightening Torques - Main Circuit Sensors
Note: Stranded wire (0 to 25mm2) consists of 7 wires or less. Stranded wire (35 to 120mm2) consists of 19 wires or less. Flexible stranded wire consists of more wires
Relays/
than the above. Timers
Comm.
Wire Sizes, Tightening Torques - Main Circuit Wire Sizes, Tightening Torques - Control Circuit
Thermal Overload Relay Type TK-E02-xxx Terminal
Single Stranded Wire One 0.75 to 2.5 ( ø 1 to ø 1.6) Blocks &
Solid Wire One 0.75 to 4 Wiring
(mm2) Two 0.75 to 2.5
(mm2) Two 1 to 4 Power
One 0.75 to 4 One 18 to 14
Stranded Wire AWG Circuit
(mm2) Two 1 to 4 Two 18 to 14 Protection
20
Minute
10
8 10
8
5
Operating time
Operating time
3
Overcurrent (cold start) 3
2 Overcurrent (cold start)
2
60
60
40
30 40
30
20
20
10
8 10
Open-phase 8 Open-phase
6
Second
6 (cold start)
4 (cold start) Second 4
3
3
2
2
1 Overcurrent (hot start)
1 Overcurrent (hot start)
0.8
0.8
0.6
0.6
0.4
0.4
0.3
0.8 1 1.5 2 3 4 5 6 7 8 9 10 15 0.3
0.8 1 1.5 2 3 4 5 6 7 8 9 10 15
Multiple of setting value x Ie (A)
Multiple of setting value x Ie (A)
Optional accessories
SZ-HCE Base Unit
Base units for separate
mounting
Allows TK-E02, E2, and E3 series thermal Install thermal overload relay onto
base unit as shown. Relay can now
overload relays to be separately mounted be installed onto DIN rail or panel.
to 35mm wide DIN rail, or screw
mounted to panel.
90
99
61
8.5 Mounting
59 hole
SZ-HCE 100.5 5 2-M4 54
SZ-HDE
SZ-HCE SZ-HEE
104 68
83 78 1 0.5
Main 51 9
67.5 terminal 8 8.5
Main
7 M4
5
109.5
72
60
68
47
Mounting
hole
35 2-M4 Mounting
84 3 8 35 64 hole
SZ-HEE 5 2-M4 68
53 106
Volume 13
Systems
Overview
Programmable
Dimensions (mm) Controllers
D
D
Aux.
A
14
C
terminal Aux. Soft
67.5
53
M3.5(NO) terminal Starters
14
M3.5(NC)
37
78.5
46.5
Motors &
27.5
Reset button Gearbox
(Resetting
stroke: 3mm) Aux.
28 10 13 7.7 terminal Steppers/
50.5 Servos
77 3 26.5 M3.5(NC) Main
92 5 7.3
Main terminal
A terminal 53 A 10.5
Motor
B M4 B 54 Controls
Aux. 32 32
Aux.
235
terminal 9.8
8
89.5
60
76
terminal
106.5
67
29
105
Temperature
115
Sensors
29
Aux. 97 95 Enclosures
D
terminal
M3.5(NO)
77.5
107.5
Tools
122
60
43
Volume 13
Trip-free design prevents holding the Compatible with Fuji SC-E series
MMS in the ON position during a trip contactors for a complete motor
condition control solution
Auxiliary and Shunt trips and MMS external handles MMS Busbars
alarm contact undervoltage
blocks releases
Volume 13
Systems
Overview
Programmable
General Information Controllers
• cUL listed, file E163944, CSA C22.2 No.14 contact block) and BZ0TCRE (line side contact block).
Pressure
• TÜV, CE terminal cover). Sensors
• cULus listed for group installation per
Temperature
NEC 430-53(c) Sensors
Pushbuttons/
Characteristic curves Lights
BM3RHB Process
BM3VHB
10000 10000
Relays/
Timers
Comm.
1000 1000
Terminal
Blocks &
Wiring
100 100 3-phase cold start
3-phase cold start
Power
Operating time (s)
10 10 Circuit
Protection
Enclosures
Instantaneous trip 3-phase hot start Instantaneous trip
1 3-phase hot start 1100 to 1560% of 1 1100 to 1560% of
max. setting current max. setting current Tools
Pneumatics
0.1 0.1
Appendix
Part #
0.001 0.001
Index
1 10 100 1 10 100
Multiple of rated current (A) Multiple of rated current (A)
Volume 13
Systems
Overview
BM3VHB-xxx Specifications
Programmable
Controllers
General Specifications: 55 mm Frame Width - BM3VHB-XXX Series
Adjustable Current Range UL/CSA 3-Phase hp Rating1 Instant- UL/CSA Short Circuit Max. Listed Field I/O
aneous Branch Circuit
Part Number Price Trip Current Rating (kA)2 Protection -
le: Min.-Max. 200- 220- 440- 550- Fuse or MCCB
Software
Part #
Index
Volume 13
Snap
1
5mm or less dia. Arc Space Requirements
BM3VHB-xxx
Arc Space Requirements
BM3RHB-xxx
Rated operational Minimum distance to grounded
Push-in lug voltage Ue metal (mm)
BZ0SET Part Number
(V) A,B C,D
M4
Up to 500 15 30
BM3RHB-XXX
M4 Up to 690 40 50
Up to 500 15 40
BM3VHB-XXX
Up to 690 40 50
M4
M4
A B When frames are mounted
C
Mounting angle side-by-side, operating conditions
30°
such as a high ambient tempera-
90° ture or using the maximum setting
180° 180° for continuous carrying current
may cause slight changes in operat-
ing characteristics due to tempera-
ture rises. Under such conditions,
it is recommended that the frames
be separated by at least 5mm.
D
Wiring
While pressing the wire with a screwdriver, Grounded metal
tighten the screw to the specified
tightening torque.
Volume 13
Accessories
Systems
Overview
Programmable
Controllers
Optional Installation of optional contact
accessories blocks and trip devices Field I/O
Left side-mount optional auxiliary, alarm or Right side-mount optional shunt or undervoltage Encoders
short-circuit contact block trip device
Current
Sensors
Pressure
Sensors
Temperature
Sensors
Pushbuttons/
External operating handles Lights
Process
Auxiliary contact blocks
Relays/
Timers
Comm.
or
Terminal
Blocks &
Wiring
Mounts to left
side of MMS Power
Enclosures
Auxiliary Contact Blocks
Tools
Part Number Price Description Starter Type Mounting Contact Weight
Arrangement (g/lb)
Pneumatics
BZ0WIA <--->
These contact blocks do not discriminate between OFF,
1NO
Front 9/0.02
BZ0WIB <---> overload, phase-loss, or short circuit. The blocks are 1NC Appendix
linked to the ON/OFF operation of the MMS, and also BM3RHB-XXX
BZ0WUAAL <---> operate in the event of an overload, phase-loss, or short 2NO
circuit. Up to two contact blocks can be mounted to the BM3VHB-XXX Product
BZ0WUABL <---> right/left front, and up to two contact blocks can be Left side 1NO + 1NC 45/0.1 Index
mounted to the left sides.
BZ0WUBBL <---> 2NC
Part #
Index
Volume 13
BZ0TKUAB
Volume 13
Accessories Systems
Overview
Programmable
Accessories (continued) Mounts to right
Controllers
side of MMS
Field I/O
Software
BZ0FAZU
Drives
Photo
Sensors
Mounts to right
side of MMS Limit
Switches
Encoders
Part Number Price Description Starter Type Mounting Contact Weight Temperature
Arrangement (g/lb) Sensors
BZ0RAZ2U <---> This device automatically trips the MMS when the control 24V 60Hz Pushbuttons/
circuit voltage drops below the specified value. Lights
Notes: This device cannot be used together with a
BM3RHB-XXX Process
BZ0RDZU <---> shunt trip device.
BM3VHB-XXX
Right 110-127V 50Hz/120V 60Hz 115/0.25
When the MMS has been tripped with the
undervoltage trip device, press the reset but- Relays/
BZ0R4ZU <---> ton before turning ON the power. 415-440V 50Hz/460-480V Timers
60Hz
Comm.
Terminal
Blocks &
Wiring
Push-in lug BZ0SET
Power
Pneumatics
Product
Terminal Cover Index
Volume 13
BZ0VBBL BZ0VYRL
BZ0VBBL <---> • Used to operate an MMS installed inside a panel, from the outside of the Standard (black) 160/0.35
panel.
• Equipped with an interlock mechanism that prevents someone from BM3RHB-XXX
mistakenly opening the panel door when the MMS is in the ON state. Emergency
BZ0VYRL <---> • The shaft can be cut to match the distance between the MMS and the panel (red/yellow) 160/0.35
door.
• Door interlock function • OFF lock function
BZ0VBBM <---> • Can be locked OFF with up to three padlocks. Standard (black) 160/0.35
Note: Padlocks are to be provided by the customer.
• Release screw allows the door to be opened with the handle in the ON BM3VHB-XXX
position.
BZ0VYRM <---> Emergency 160/0.35
• IP54 enclosure (red/yellow)
Accessory
specifications
Trip Device Specifications
Shunt trip device Undervoltage device
Accessory Type and Part Number
BZ0Fxxx BZ0Rxxx
Standard IEC 60947-1, UL 508
IEC 60947 690
Rated Insulation Voltage (VAC)
UL 508 600
No. of ON-OFF Operations 5000
Operating Time (ms) 20
Inrush (VA/W) 21/12
Power Consumption
Sealed (VA/W) 8/1.2
Tripping Voltage (V) 0.7 to 1.1 Ue 0.35 to 0.7 Ue
Voltage Range
Closing Voltage (V) - 0.85 to 1.1 Ue
AC: Continuous
Time Rating of Coil (s) AC: Continuous
DC: 5
Volume 13
Accessories Systems
Overview
Programmable
Controllers
Software
Contact Block Specifications
Auxiliary contact Auxiliary contact Alarm contact Aux. and alarm Short-circuit alarm C-more &
block/front block/side block contact block contact block other HMI
125VAC 3 4 3 4 4 Steppers/
Servos
230VAC 1.5 4 1.5 4 4
400VAC 2.2 2.2 2.2 Motor
Controls
Rated Operational 500VAC (note 3) 1.5 (note 3) 1.5 1.5
Current (A)
Proximity
690VAC 0.6 0.6 0.6 Sensors
48VDC DC-13 (note 2) 1.38 5 1.38 5 5
Photo
110VDC 0.55 1.3 0.55 1.3 1.3 Sensors
Note 2: IEC utilization category. For more information, refer to page 17-78.
Pressure
Note 3: The indicated contacts should not be used in control circuits higher than 300V. Sensors
Temperature
Sensors
Pushbuttons/
Dimensions (mm) Lights
Process
Manual motor starters
Relays/
Timers
27
3.3
33.8 Circuit
105
Protection
90
75
45
95
3.3
120
110
45
66
84
45
Dia. 5 14.3 75.3 3.7 Pneumatics
81.3 4.2
42
Appendix
Product
Index
Part #
Index
Volume 13
Auxiliary contact blocks, front mounting Auxiliary contact blocks, side mounting Alarm contact blocks, front mounting
BZ0WIA, BZ0WIB BZ0WUAAL, BZ0WUABL, BZ0WUBBL BZ0KIA, BZ0KIB
9 M3.5 66 M3.5
9
48.7
35.7
10.5 9
2.3
16.7
38.8
38.8
70.4
53.6
47.2
45
90
18.9 8.5 1
18.9 8.5
Auxiliary and alarm contact blocks Short-circuit alarm contact block Shunt trip devices BZ0Fxxxx
BZ0WKUAA Undervoltage trip devices BZ0Rxxxx
BZ0TKUAB 66
66
66 48.7
Indication 48.7 48.7
35.7 18
9 2.8 18.7
2.3
70.4
47.2
90
45
90
47.2
70.4
53.6
45
90
110
120
45
90
45
95
90
75.3 3.7
Volume 13
Accessories Systems
Overview
Programmable
Controllers
Dimensions
(continued - mm) Field I/O
Software
External operation handle
dimensions and panel drilling C-more &
other HMI
66
Soft
Panel drilling Starters
Panel Locked
Mounting screw CL of Motors &
CL of handle Gearbox
Max. 68
4-Dia.3.5 CL
handle
66
Steppers/
.28 Servos
3.3
Dia
52.6
CL of CL of CL
MMS Shaft handle
Motor
Min. 75 Controls
Door hinge
45
5.5 Top of handle 52.6
Proximity
Panel thickness 1.5 to 5 Type A Sensors
CL of MMS CL of handle X BM3RH 48.5
BM3V 58.5 Photo
A Sensors
Type X min. X max.
BZ0VBBL, BZ0VYRL 139 ±2 289 ±2
Limit
BZ0VBBM, BZ0VYRM 156 ±2 306 ±2 Switches
Encoders
Pushbuttons/
Lights
Process
78
74
Relays/
2 4 6 Timers
T1 T2 T3 Comm.
Terminal
Blocks &
Wiring
Alarm contact blocks
Power
Front mounting
Circuit
BZ0KIA BZ0KIB Protection
27 25
Enclosures
Tools
Pneumatics
28 26
Appendix
Product
Index
Part #
Index
Volume 13
13(23) 11(21)
14(24) 12(22)
Side mounting
BZ0WUAAL BZ0WUABL BZ0WUBBL
33(133)
31(131) 31(131)
43(143)
43(143) 41(141)
44(144)
34(134) 44(144) 42(142)
32(132) 32(132)
D2
C2
76
74
Volume 13
Accessories Systems
Overview
Programmable
Busbar system Busbar
Controllers
Motor
Controls
Proximity
Sensors
Limit
Switches
Encoders
Current
Sensors
BZ0BR13A BZ0BR14A BZ0BR15A BZ0BV02A BZ0BV03A
Note: Busbar photos continued on next page. Pressure
Sensors
Volume 13
Dimensions (mm)
14 14 2 4 4 2.5
45 17 17
55
215
205
170
151
125
13.5
97
12.5
80
5
2
12
33
30
24
23
13
16 20
BZ0BR02A: 80 mm
BZ0BR03A: 125 mm BZ0BV02A: 97 mm
BZ0BR04A: 170 mm BZ0BV03A: 151 mm
BZ0BR05A: 215 mm BZ0BV04A: 205 mm
BZ0BR1xx With 1 external accessory BZ0BV1xx With 1 external accessory, 9mm wide
27.5
4 2.5
14 14 2 4
17 17
54 64
251 232
197 169
143 106
13.5
12.5
89
2
12
33
30
24
23
13
16 20
BZ0BR12A: 89 mm
BZ0BR13A: 143mm BZ0BV12A: 106 mm
BZ0BR14A: 197 mm BZ0BV13A: 169 mm
BZ0BR15A: 251 mm BZ0BV14A: 232 mm
6-25mm2
2
(10-4 AWG)
27
54
24
44.5
54
14.5 14.5
5
M4 17 17 M4
Hexagon socket head bolt
13.5
25
29
17
4
6.5
1.9
3 14.5 14.5 3.8 7 17 17 6
Volume 13
Starter Systems
Overview
Programmable
Controllers
The Fuji SC-E series contactors work with the 1/2 to 40 hp at 480 V
MMS to create starters for particular applica-
when used with SC-E contactor Field I/O
tions. The MMS combination starters can
accommodate motors up to 40 horsepower at Software
480 VAC or 60 horsepower at 600 VAC.
C-more &
other HMI
Drives
Combination starters used for:
Soft
• Induction motor starting and control Starters
• Fulfillment of NEC 430
Motors &
• UL508E, type 2 coordination for group motor Gearbox
rating installation (See parts list for details)
Steppers/
SC-E Series Contactor Features Servos
Temperature
Sensors
Pushbuttons/
Lights
Process
Relays/
Timers
Comm.
Part #
Index
Volume 13
+ + + =
BZ0L Series Link
SC-E Series Contactor Module UL Type E
BM3 Series Manual Self-Protected
Motor Starter BZ0BP Series Manual Motor Controller
Base Plate and Contactor
Volume 13
Table - 45 mm
Systems
Overview
Programmable
Use this selection table to select 45 mm frame width (A) Manual Motor Starter, (B) Contactor, (C) Link Controllers
Software
Combination Starter Selection Table - 45 mm
C-more &
Three Phase Motor A B C D other HMI
SC-E1-110VAC BZ0LVE51AA
3 9.6 5 7.6 6.3 to 10 BM3VHB-010 65
SC-E1G-24VDC BZ0LVE51GA
SC-E1-110VAC BZ0LVE51AA
3 9.6 7.5 11 9 to 13 BM3VHB-013 65
SC-E1G-24VDC BZ0LVE51GA
SC-E1-110VAC BZ0LVE51AA
5 15.2 10 14 11 to 16 BM3VHB-016 65
SC-E1G-24VDC BZ0LVE51GA
SC-E1-110VAC BZ0LVE51AA
5 15.2 10 14 14 to 20 BM3VHB-020 65
SC-E1G-24VDC BZ0LVE51GA
BZ0BPVE51A
SC-E1-110VAC BZ0LVE51AA
7.5 22 15 21 19 to 25 BM3VHB-025 65
SC-E1G-24VDC BZ0LVE51GA
SC-E1-110VAC BZ0LVE51AA
10 28 20 27 24 to 32 BM3VHB-032 65
SC-E1G-24VDC BZ0LVE51GA
SC-E2-110VAC BZ0LVE51AA
10 28 30 40 28 to 40 BM3VHB-040 65
SC-E2G-24VDC BZ0LVE51GA
SC-E2S-110VAC BZ0LVE51AA
15 42 30 40 35 to 50 BM3VHB-050 65
SC-E2SG-24VDC BZ0LVE51GA
SC-E3-110VAC BZ0LVE65AA
20 54 40 52 45 to 63 BM3VHB-063 BZ0BPVE65A 65
SC-E3G-24VDC BZ0LVE65GA
Note 1: When a horsepower rating is listed on two rows, the motor full-load amperage must be known so you can select the MMS with the best adjustable current range
for your application. For example, if you have a 230V, 10 hp, 28A motor, you can select a MMS with either a 24-32A range or a 28-40A range. Consult the motor
data plate or motor manufacturer.
Note 2: When using BM3VHB-xxx MMS in a UL Type E application, you must also use part number BZ0TKUAB (short-circuit contact block).
Note 3: For AC coil voltages other than 110VAC, substitute the “110VAC” in the part number with “220VAC” for 220/240VAC coils or “24VAC” for 24VAC coils. For exam-
ple, if the table lists a SC-E1-110VAC contactor for your application and you need a contactor with a 220VAC coil, use contactor SC-E1-220VAC.
Note 4: Per NEC 2005 Table 430.250
Volume 13
Systems
Overview
BM3RHB-P40 <---> BM3RHB-013 <---> BM3VHB-016 <---> BM3VHB-050 <---> C-more &
BM3RHB-P63 <---> BM3RHB-016 <---> other HMI
BM3VHB-020 <---> BM3VHB-063 <--->
BM3RHB-001 <---> BM3RHB-020 <---> Drives
BM3VHB-025 <--->
BM3RHB-1P6 <---> BM3RHB-025 <--->
BM3RHB-2P5 <---> BM3RHB-032 <---> Note: When using BM3VHB-xxx MMS in a UL type E Soft
application you must also use part number Starters
BM3RHB-004 <---> BZ0TKUAB (short circuit contact block).
Motors &
Note: When using BM3RHB-xxx MMS in a UL type E application, you Gearbox
must also use part number BZ0TKUAB (short circuit contact
block) and BZ0TCRE (line side terminal cover). Steppers/
Servos
Contactor Prices
Motor
Part Number Price Part Number Price Part Number Price Part Number Price Controls
BZ0LRE22A Relays/
Link modules BZ0LRE22GA BZ0LRE32AA BZ0LRE32GA BZ0LVE51AA Timers
Comm.
Terminal
Blocks &
Wiring
Circuit
Link modules Protection
Part Number Price Description Applicable MMS Applicable Magnetic Contactor Operating Coil (V) Weight (g/lb) Enclosures
BZ0LRE22AA <---> SC-E02, E03, E04, E05-xxxVAC AC 25/0.055
Tools
BZ0LRE22GA <---> SC-E02G, E03G, E04G, E05G-xxxVDC DC 35/0.077
BM3RHB-xxx
Pneumatics
BZ0LRE32AA <---> SC-E1-xxxVAC AC 45/0.1
BZ0LRE32GA <---> The link module connects the SC-E1G-xxxVDC DC 60/0.13
manual motor starter and mag- Appendix
netic contactor electrically and
BZ0LVE51AA <---> mechanically. SC-E1, E2, E2S-xxxVAC AC 45/0.1
Product
BZ0LVE51GA <---> SC-E1G, E2G, E2SG-xxxVDC DC 60/0.13 Index
BM3VHB-xxx
BZ0LVE65AA <---> SC-E3-xxxVAC AC 65/0.14 Part #
Index
BZ0LVE65GA <---> SC-E3G-xxxVDC DC 80/0.176
Volume 13
Base Plates
Part Number Price Description Applicable MMS Applicable Magnetic Contactor Operating Coil (V) Weight (g/lb)
SC-E02, E03, E04, E05, SC-E02G, E03G,
BZ0BPRE22A <--->
E04G, E05G-xxx
AC/DC 100/0.22
BM3RHB-xxx
BZ0BPRE32A <---> The base plate is a plastic plate to SC-E1, SC-E1G-xxx AC/DC 160/0.35
which the combination starter is
mounted. The base plate can then be
mounted to a panel with screws or to
BZ0BPVE51A <---> a DIN rail. SC-E1, E2, E2S, SC-E1G, E2G, E2SG-xxx AC/DC 160/0.35
BM3VHB-xxx
BZ0BPVE65A <---> SC-E3, SC-E3G-xxx AC/DC 195/0.43
SC-E2S
For SC-E02 to SC-E05-xxx
contactors
• Insert a flat-blade screwdriver between
the arc-chamber of the S phase or V phase
and the terminal screw, and lift the arc- SC-E04
Volume 13
Systems
Overview
Programmable
Dimensions (mm) Controllers
5
7 2 C-more &
other HMI
5
40
40
102.5
Drives
Soft
125
Starters
Motors &
195
205
235
247
Gearbox
125
Steppers/
Servos
Motor
Controls
Proximity
Sensors
7 5
8 8
21.3
25 Photo
Sensors
1 35mm wide rail (height 15mm) x 2 1 35mm wide rail (height 15mm) x 2
2 75mm wide rail (height 25mm) x 1
Limit
Switches
Base plate MMS Contactor
Base plate MMS Contactor Encoders
BZ0BPRE32A BM3RHB-xxx SC-E1, E1G-xxx
BZ0BPRE22A BM3RHB-xxx SC-E02, E03, E04, E05-xxx
Current
E02G, E03G, E04G, E05G-xxx Sensors
Pressure
Sensors
Temperature
BZ0BPVE51A BZ0BPVE65A 66 Sensors
Mounting hole
9 48 (to 56) 3-M4
55 Mounting hole Pushbuttons/
4
8 39 (to 48) 3-M4 Lights
5
8 4.5
5
40
Process
40
102.5
Relays/
102.5
Timers
125
125
Comm.
Terminal
235
247
260
270
Blocks &
Wiring
Power
Circuit
Protection
Enclosures
8 8
25 8 9 Tools
1 35mm wide rail (height 15mm) x 2 25
2 75mm wide rail (height 25mm) x 1
1 35mm wide rail (height 15mm) x 2 Pneumatics
2 75mm wide rail (height 25mm) x 1
Base plate MMS Contactor
Appendix
BZ0BPVE51A BM3VHB-xxx SC-E1, E2, E2S-xxx Base plate MMS Contactor
E1G, E2G, E2SG-xxx Product
BZ0BPVE65A BM3VHB-xxx SC-E3, E3G-xxx Index
Part #
Index
Volume 13
17.6
17.6
5
5
40
40
55.2
55.2
3.3
3.3
45
45
5.5 5.5
125
125
162.8
162.8
195
205
195
205
7 5 13 7 5 13
82.3 109.3
102.3 129.3
1 35mm wide rail (height 15mm) x 2 1 35mm wide rail (height 15mm) x 2
111.8 138.8
MMS Contactors Link module Base plate Mass (g MMS Contactors Link module Base plate Mass (g)
BM3RHB-xxx SC-E02, E03, E04, E05-xxx BZ0LRE22AA BZ0BPRE22A 840BM3RHB-xxx SC-E02G, E03G, E04G, E05G-xxx BZ0LRE22GA BZ0BPRE22A 1,085
5
32.4
32.4
40
40
70
70
102.5
102.5
3.3
3.3
45
45
5.5 5.5
22.5 22.5
185.1
185.1
247
235
247
235
125
125
8 8 16.5 8 8 16.5
90.5 116
121 146.5
1 35mm wide rail (height 15mm) x 2 1 35mm wide rail (height 15mm) x 2
137.5 2 75mm wide rail (height 25mm) x 1 162.8 2 75mm wide rail (height 25mm) x 1
MMS Contactors Link module Base plate Mass (g MMS Contactors Link module Base plate Mass (g)
BM3RHB-xxx SC-E1-xxx BZ0LRE32AA BZ0BPRE32A 1,155 BM3RHB-xxx SC-E1G-xxx BZ0LRE32GA BZ0BPRE32A 1,380
Volume 13
Systems
Overview
Programmable
Controllers
Dimensions (mm)
Field I/O
BM3VHB-xxx + SC-E1, E2, E2S-xxx BM3VHB-xxx + SC-E1G, E2G, E2SG-xxx
137 137 Software
121.5 121.5
117.5 Mounting 55 117.5 Mounting 55
hole hole C-more &
63 8 39 (to 48) 63 8 39 (to 48)
3-M4 3-M4 other HMI
8 16.5 8 16.5
5
Drives
28
28
40
40
Soft
70
70
102.5
102.5
3.3 Starters
3.3
Motors &
66
45
45
125
66
125
5.5 5.5 Gearbox
189.5
189.5
235
247
235
Steppers/
Servos
Motor
Controls
Proximity
Sensors
Photo
Sensors
8 8 16.5 8 8 16.5
90.5 116 Limit
Switches
121 1 35mm wide rail (height 15mm 146.5 1 35mm wide rail (height 15mm) x 2
137.5 2 75mm wide rail (height 25mm 162.8 2 75mm wide rail (height 25mm) x 1
Encoders
MMS Contactors Link module Base plate Mass ( MMS Contactors Link module Base plate Mass (g)
BZ0BPVE51A 1,810 Current
BM3VHB-xxx SC-E1, E2, E2S-xxx BZ0LVE51AA BZ0BPVE51A 1,58 BM3VHB-xxx SC-E1G, E2G, E2SG-xxx BZ0LVE51GA Sensors
Pressure
Sensors
28
28
40
40
Relays/
70
70
102.5
Timers
102.5
3.3
3.3
Comm.
45
66
66
11
45
11
125
125
Terminal
Blocks &
Wiring
215.5
215.5
260
270
260
270
Power
Circuit
Protection
Enclosures
Tools
8 9 8 9 20.5
20.5
97.5 67 (SC-E3) 116.5 67 (SC-E3/G) Pneumatics
136 155
152.2 171.2 1 35mm wide rail (height 15mm) x 2
1 35mm wide rail (height 15mm) x 2 Appendix
2 75mm wide rail (height 25mm) x 1 2 75mm wide rail (height 25mm) x 1
Product
MMS Contactors Link module Base plate Mass (g) MMS Contactors Link module Base plate Mass (g) Index
BM3VHB-xxx SC-E3-xxx BZ0LVE65AA BZ0BPVE65A 2,080 BM3VHB-xxx SC-E3G-xxx BZ0LVE65GA BZ0BPVE65A 2,400
Part #
Index
Volume 13
Thermal Current
of
SCCR Ratings
Frame Width
Auxiliary
Part Number Fuji
Rated AC-3
Rated AC-1
Price Coil Voltage 3-Phase 1-Phase Contacts
(A) [note 2]
Type
200– 220– 440– 550– 100– 220–
(mm)
(KA)
208V 240V 480V 600V 120V 240V NO NC
3NC4Q0E22 <---> 24–25VAC / 24VDC
3NC4Q0122 <---> 100–127VAC / 100–120VDC
3NC4Q0222 SC-N8 <---> 200–250VAC / 200–240VDC 60 60 150 150 180 260
3NC4Q0Q22 <---> 380–450VAC
3NC4Q0422 <---> 460–575VAC
10 138
3NC4H0E22 <---> 24–25VAC / 24VDC
3NC4H0122 <---> 100–127VAC / 100–120VDC
3NC4H0222 SC-N10 <---> 200–250VAC / 200–240VDC 75 75 150 200 221 260
3NC4H0Q22 <---> 380–450VAC
3NC4H0422 <---> 460–575VAC
N/A 2 2
3NC5F0E22 <---> 24–25VAC / 24VDC
3NC5F0122 <---> 100–127VAC / 100–120VDC
3NC5F0222 SC-N11 <---> 200–250VAC / 200–240VDC 100 100 200 250 285 350
3NC5F0Q22 <---> 380–450VAC
3NC5F0422 <---> 460–575VAC
18 148
3NC5H0E22 <---> 24–25VAC / 24VDC
3NC5H0122 <---> 100–127VAC / 100–120VDC
3NC5H0222 SC-N12 <---> 200–250VAC / 200–240VDC 125 150 300 350 361 450
3NC5H0Q22 <---> 380–450VAC
3NC5H0422 <---> 460–575VAC
Notes: 1. AC3 type loads consist of squirrel cage three-phase motors; occasional, limited jogging duty.
2. AC1 non-inductive or slightly inductive loads. Typically resistive loads (i.e. furnaces, ovens, etc.)
Systems
Contactor Coil Characteristics - DC Input - 110VDC Overview
Power Consumption (watts) Operating Time (ms)
Part Number Pick-up Voltage Drop-out Voltage Programmable
Inrush Sealed (V) (V) Coil ON to Coil OFF to Controllers
Contact ON Contact OFF
3NC4Qxxxx, 3NC4Hxxxx 324 4.1 77-88 28-44 35-41 37-45 Field I/O
3NC5Fxxxx, 3NC5Hxxxx 340 4.5 77-88 28-44 40-47 36-43
Software
NOTE: This data is based on 100-120V SUPERMAGNET™ coil, tested at 110VDC.
C-more &
Contactor Coil Characteristics - DC Input - 24VDC other HMI
SZ-N8T <---> Terminal cover for line or load 3NC4Qxxxx, 3NC4Hxxxx contactors Power
side. Prevents contact with elec-
SZ-N11T <---> trified contactor terminals. 3NC5Fxxxx, 3NC5Hxxxx contactors
Circuit
SZ-N8T SZ-N11T Protection
Odyssey Series Replacement Contactor Coils
Enclosures
Applicable
Replacement contactor coils Part Number Price Coil Voltage
Contactors Tools
SZ-GSN8-100 <---> 3NC4Q0122, 3NC4H0122 100-127VAC/100-120VDC
Pneumatics
SZ-GSN11-100 <---> 3NC5F0122, 3NC5H0122 100-127VAC/100-120VDC
Appendix
SZ-GSN8-200 3NC4Q0222, 3NC4H0222 200-250VAC/200-240VDC
SZ-GSN11-200 3NC5F0222, 3NC5H0222 200-250VAC/200-240VDC Product
Index
SZ-GSN8-24 <---> 3NC4Q0E22, 3NC4H0E22 24-25VAC/24VDC
Part #
SZ-GSN11-24 <---> 3NC5F0E22, 3NC5H0E22 24-25VAC/24VDC Index
SZ-GSN11-100
Replacement coils are not available for coil codes Q and 4 (380–450VAC and 460–575VAC).
Volume 13
3NC4Q0#22 3NC5F0#22
3NC4H0#22 3NC5H0#22
Main
174 terminal (154) *1 Coil terminal Main
118 M10 138 M3.5 195 terminal (169) *1
Coil terminal
14.5 47 47 M12 148
12.2
132 M3.5
Aux. 14.5 56 56
15
terminal
M3.5 Aux.
terminal
M3.5
155
209
190
240
25
30
* 1 Aux. contact block (Side mounted) Weight: 4.9kg
* 1 Aux. contact block (Side mounted) Weight: 7.8kg
Mounting dimensions
A
C
Frame A B C Screw
Size Size
Wiring diagrams
Non-reversing Contactors
Volume 13
Systems
Overview
or open phases.
Software
Motors &
Odyssey Series Overload Relays Gearbox
Specifications Lights
Process
Power
Circuit
Wire Terminal Tightening Torque Chart Protection
Part Number Contactor or Terminal Size Cable Size Maximum Applicable Max. Width for Tightening Torque Enclosures
Starter Ring Terminal
Tools
3NK4Qx 3NC4Q0 M10 300MCM (152mm2) 36.5mm 133-177 in.lbs., 15-20 Nm
3NK4Hx 3NC4H0 M10 300MCM (152mm2) 36.5mm 133-177 in.lbs., 15-20 Nm Pneumatics
3NC5F0 Appendix
3NK5Hx M12 400MCM (203mm2) 44.5mm 310-399 in.lbs., 35-45 Nm
3NC5H0
Product
Index
Part #
Index
Volume 13
+ =
3N Overload Relay
3N Contactor
Volume 13
Systems
Overview
Programmable
Specifications Controllers
Motors &
Gearbox
Open-phase protection
Steppers/
Servos
3NK4Qx
Motor
Cold start Hot start Controls
80 80
60 60 Proximity
Sensors
30 30
20 20
Minutes
Photo
Minutes
10 10 Sensors
3 3
5 5
Limit
3 3 Switches
Tripping time
Tripping time
2 2
60 60
Encoders
40 40
30 30
20
Current
20
Sensors
10 10
3 3
6 Pressure
Seconds
6
Seconds
4 Sensors
4
3 3
2 2 Temperature
Sensors
1 1
0.8 0.8
0.6 0.6
0.4
Pushbuttons/
0.4 Lights
0.3 0.3
0.8 1 1.5 2 3 4 5 6 7 8 9 10 15 0.8 1 1.5 2 3 4 5 6 7 8 9 10 15
Multiple of current setting Xin [A] Multiple of current setting Xin [A] Process
Minutes
10
3 10
3 Power
5
5
3
3 Circuit
Tripping time
2
Tripping time
2 Protection
60
60
40
40 Enclosures
30
30
20
20
Tools
10
10
3
3
6
Pneumatics
Seconds
6
Seconds
4
4
3
3
2
2 Appendix
1
1
0.8
0.8 Product
0.6
0.6 Index
0.4
0.4
0.3
0.3
0.8 1 1.5 2 3 4 5 6 7 8 9 10 15
0.8 1 1.5 2 3 4 5 6 7 8 9 10 15
Part #
Multiple of current setting Xin [A] Multiple of current setting Xin [A] Index
Volume 13
Applicable Contactors,
Part number Price Description
Overload Relays
SZ-WN8T <---> 3NK4Qx overload relays
Terminal cover for load side.
SZ-WN10T <---> Prevents contact with electrified 3NK4Hx overload relays
contactor terminals.
SZ-WN11T <---> 3NK5Hx overload relays
Dimensions (mm)
3NK4Hx
3NK4Qx
Resetting bar
Reset button 47 47
117 Aux. terminal
169 Aux. terminal 47 47 M3.5
Aux. terminal 4.9 M3.5
12.5
41
135.5
92
118
55
109
7 Main terminal
3.2 20 45 22 M10
25 155 138
115
47 47
154 4.7 119
Weight: 1.2kg
Weight: 1.85kg
3NK5Hx
169
Resetting bar
56 56
Wiring diagrams
125 Aux. 5.5 Aux. terminal
15
terminal M3.5
M3.5 (NC) 3NK4Qx 3NK4Hx, 3NK5Hx
3 (NO)
61
160.5
128
Main
3.2 terminal
81 56 56 M12
155 10
60 30
142
Weight: 2.3kg
Volume 13
1-800-633-0405 www.automationdirect.com
GH Series IEC Motor Controls
The GH series of IEC contactors and bi- We offer individual components that allow Use contactors wherever you need a
metallic overload relays are manufactured you to use the contactor alone or to heavy-duty switching device with up to
by Europe’s leading maritime contactor assemble your motor starter using our three poles. Add up to eight auxiliary
company. Contactors for ocean-going thermal overload relays. You can also contact blocks for interlocks and feedback.
vessels are built to the most rigid specifica- combine a manual motor starter/protector Or use the optional mechanical interlock
tions. This same design technology carries for all-in-one protection. to create an inexpensive reversing
over to this line of industrial motor controls. contactor.
Actuator coils,
available in
Self-lifting pressure plate 120 and 220 VAC,
terminals make for quick 60Hz models,
wiring terminations. accommodate most
applications.
Terminals are
IP20 rated to
protect fingers
from electrical
shock.
Volume 13
Systems
Overview
Contactor Part Numbers
Programmable
Number of Contacts Additional Contacts Controllers
IEC FRAME Contactor Part Number Price Auxiliary Contacts Coil Voltage and
SIZE Model Main Included Frequency Maximum Contact Type of Additional
Block Arrangement Contact Block Field I/O
N.0 N.C.
Software
GH15BN-3-10A <---> 3 1 110-120VAC 50-60 Hz
GH15BN-3-01A <---> 3 1 110-120VAC 50-60 Hz C-more &
GH15BN other HMI
GH15BN-3-10B <---> 3 1 220-240VAC 50-60 Hz
GH15BN-3-01B <---> 3 1 220-240VAC 50-60 Hz Drives
Temperature
Sensors
Pushbuttons/
Lights
Process
Relays/
Timers
Comm.
Terminal
Blocks &
Wiring
Power
Circuit
Protection
Enclosures
Tools
Pneumatics
Appendix
Product
Index
Part #
Index
Volume 13
Volume 13
Systems
Overview
Coil Voltage Operating Limits A.C.Pick-up 85-110% rated control voltage / A.C. Drop-Out 20-75% Limit
rated control voltage Switches
Average Coil Power Requirements / Coil current (A) = VA/Coil Voltage A.C. Pick-up (VA) 250 / A.C. Sealed (VA) 18
Encoders
Power Factor Pick-up .54 / Sealed .35
Coil Operating Time at Rated Coil Voltage Pick-up (ms) 12-30 / Drop-out (ms) 6-15 Current
Sensors
Maximum Operating Frequency (No-Load Operation) 3000 operations / hour
Mechanical Durability 10,000,000 operations Pressure
Sensors
Electrical Durability 1,000,000 operations
Operating Ambient Temperature -25 to +55C (- 13 to +131F) Temperature
Sensors
Electrical Protection Degree IP20 (IP10 for power entry cables)
Mounting Screw or 35mm DIN rail Pushbuttons/
Lights
Line / Load #3-#12 stranded
Wire Sizes Process
Control & Auxiliary Contacts #12 - #16 AWG (stranded recommended)
Relays/
Notes Timers
1. AC3 type loads consist of squirrel cage three phase motors.
Comm.
2. AC1 non-inductive or slightly inductive loads. Typically resistive loads (i.e. furnaces, ovens, etc.)
3. Type 2 coordination is a protection category for IEC 60947-4-1. Section 8.2.5.1 specifies that Type 2 coordination requires that, under short circuit conditions, Terminal
the contactor or starter shall cause no danger to persons or installations, and shall be suitable for further use. The risk of minor contact welding is possible. Blocks &
Wiring
4. NEMA ICS 5-2000. For more information, refer to Control Circuit Contact Electrical Ratings, page 17-77.
Power
Contactors Circuit
Protection
Enclosures
GH15ET3-00 Tools
Part #
Index
Volume 13
E1
to install.
B
E
nickel alloy contacts.
Auxiliary Contacts
D
C
A G Part Number Price Description Mounting
F GH15T11 <---> 1 NO 1 NC Top
GH15T22 <---> 2 NO 2 NC Top
GH15ET, GH15FT, GH15GT, GH15HT and GH15JT GH15T31 <---> 3 NO 1 NC Top
Mntg. Holes for
M4 or #8 Screws GH15T40 <---> 4 NO Top
Replacement coils
(for 45 mm frame only)
C D
A G Replacement coils for the 110/120V and
220/240V units are available
F
Auxiliary
AUXILIARY Contact Blocks
CONTACT BLOCKS Replacement Coils
GH15T11 GH15T22 GH15T31 GH15T40 GH15S11
Part Number Price Description
B01-A-120 <---> 110/120V 50/60 Hz
B01-B-240 <---> 220/240V 50/60 Hz
(3) (4) Note: These coils do not work with
(fitted on left side) (fitted on right side) GH15GT, GH15HT and GH15JT.
Mechanical interlock
BM0H
BM0H
Mechanical interlocks connect two contac-
GH15xx GH15xx tors horizontally. When one contactor is
energized, the other contactor is mechani-
cally prohibited from making, even though
it may be energized. The mechanical inter-
locks work with 45 and 60 mm contactors.
Mechanical interlock
Part Number Price Description Mounting
Mechanical
BM0H <--->
interlock
Side
15mm
Volume 13
Systems
RTD32 for 45 mm Overview
Contactors Programmable
Controllers
Adjustable
current Tamper-resistant
range cover Field I/O
Software
Motors &
Gearbox
Auxiliary Steppers/
Servos
contacts
Motor
Controls
Proximity
Sensors
tors Limit
Switches
Contactors Current
Sensors
Manual
Pressure
reset Sensors
Adjustable Temperature
overload Sensors
• Four sizes for motor currents • 16 sizes for motor currents Circuit
from 20 to 65 amps from 0.4 to 32 amps Protection
• Units come with N.O. and N.C. • Units come with N.O. and N.C. Enclosures
Auxiliary auxiliary contacts auxiliary contacts
IP20 finger contacts • Mount directly to 60 mm • Mount directly to 45 mm Tools
protection contactors contactors
Pneumatics
• Class 10 trip curve • Class 10 trip curve
• UL/CUL listed, CE • UL/CUL listed, CE
Adjustable Appendix
current Product
range Index
Part #
Index
Volume 13
Trip curve
for 45 and 60 mm
overloads
GH15BN...FT + RTD32
Supplementary terminal
GH15GT ... JT + RTD65 block for 40-52A,
52-65A range only
Volume 13
Systems
Overview
Programmable
Step 1 Select your motor’s FLA (Full Load Controllers
Amperage) from column A.
Step 2 Follow across to column B to find your Field I/O
Motor
Controls
Proximity
Sensors
Motor Contactor and Overload Relay Selection Guide (When Motor FLA is Known)
A B C Photo
Price IEC Contactor Frame Size Sensors
Current Range Motor FLA Contactor Model Overload Relay
Limit
0.4 to 0.6A RTD32-60 <---> Switches
0.6 to 0.9A RTD32-90 <--->
Encoders
0.8 to 1.2A RTD32-120 <--->
1.2 to 1.8A RTD32-180 <---> Current
GH15BN up to maximum FLA of 9A Sensors
1.8 to 2.7A RTD32-270 <--->
2.7 to 4.0A RTD32-400 <---> Pressure
Sensors
4.0 to 6.0A RTD32-600 <--->
6.0 to 9.0A RTD32-900 <---> Temperature
45 mm frame size Sensors
8.0 to 11.0A RTD32-1100 <--->
GH15CN up to 12A FLA
10.0 to 14.0A RTD32-1400 <---> Pushbuttons/
Lights
10.0 to 14.0A RTD32-1400 <--->
GH15DN up to 16A FLA
13.0 to 18.0A RTD32-1800 <---> Process
Tools
Pneumatics
Appendix
Product
Index
Part #
Index
Volume 13
Undervoltage releases are also installed Wire Size Maximum 18-14 AWG
inside the MSP and trip the device when Note: Phase loss protection only works under load.
The phase loss protection is a product of the thermal overload protection circuitry.
the monitored voltage drops below a spec-
Dimensions and installation data for these products are available on our website, listed under Tech
ified level. This is to protect the motor from Support/technical and application notes/motor controls/contactors and starters/ Application Data for MS25 manual
damage when a low voltage situation starter.
occurs. Undervoltage releases may be
wired to monitor voltage at point, but are Phase loss protection
typically wired to two of the incoming lines Phase loss protection is integral to the MSP
to the motor circuit. Undervoltage releases overload protection system. Phase loss
are not to be confused with the MSP’s protection works by detecting unequal
internal phase loss protection. current in each of the phases. A mechan-
Note: A shunt release and undervoltage ical device senses the difference in the
release cannot be installed in the same position of the bi-metallic overload strips
MSP. and trips the MSP when this occurs. For
proper phase loss detection, the MSP must
be sized and adjusted to the motor it is
protecting. The phase loss protection
works only when the motor is running, and
is a product of the thermal overload
protection circuitry.
Dimensions (mm) Note: The MSP provides magnetic short
circuit protection as well as thermal over-
auxiliary
switch
load protection under IEC 60947 require-
(optional) ments. NEC 430 may require a short circuit
protection device upstream from the MSP.
It is the responsibility of the user to comply
80
35
Volume 13
Systems
Overview
Choose your motor starter/protector Motor Starter/Protector and Accessories
according to the FLA rating on your Programmable
Part Number Price Description Controllers
motor data plate. Refer to the charts on
the following page. MS25-16 <---> Motor starter protector with thermal overload release, setting range from 0.1 to 0.16A
MS25-25 <---> Motor starter protector with thermal overload release, setting range from 0.16 to 0.25A Field I/O
Accessories MS25-40 <---> Motor starter protector with thermal overload release, setting range from 0.25 to 0.4A
Software
MS25-63 <---> Motor starter protector with thermal overload release, setting range from 0.4 to 0.63A
To complete your motor starter/ protector, C-more &
there are several accessories that may be MS25-100 <---> Motor starter protector with thermal overload release, setting range from 0.63 to 1A
other HMI
used. The Auxiliary Switch (contact) has MS25-160 <---> Motor starter protector with thermal overload release, setting range from 1 to 1.6A
Drives
one normally open contact and one MS25-250 <---> Motor starter protector with thermal overload release, setting range from 1.6 to 2.5A
normally closed contact. The Shunt MS25-400 <---> Motor starter protector with thermal overload release, setting range from 2.5 to 4A Soft
Release trips when voltage is applied MS25-630 <---> Motor starter protector with thermal overload release, setting range from 4 to 6.3A
Starters
Encoders
Current
Sensors
MS25 Series Motor Starter/Protector Short Circuit Instantaneous Trip Current and Backup Fuse Recommendations Pressure
Sensors
Manual Starter/ Short Circuit Short Circuit Breaking Capacity (kA) Max Back-Up Fuses Class CC or Class J 2 Temperature
Protector Part Number Trip Current 1 Sensors
220/240VAC 460/480VAC 500 VAC 690 VAC 230 VAC 400 VAC 500 VAC 690 VAC
Pushbuttons/
MS25-16 2 50 50 50 50 * * * * Lights
MS25-25 3 50 50 50 50 * * * *
Process
MS25-40 5 50 50 50 50 * * * *
Relays/
MS25-63 8 50 50 50 50 * * * * Timers
MS25-100 12 50 50 50 50 * * * *
Comm.
MS25-160 20 50 50 50 50 * * * *
Terminal
MS25-250 33 50 50 3 2.5 * * 25 20 Blocks &
Wiring
MS25-400 44 50 50 3 2.5 * * 35 25
MS25-630 75 50 50 3 2.5 * * 50 35 Power
Note 1: The short-circuit trip is the current at which the device will instantly trip via the electromagnetic trip Pneumatics
circuitry within the MSP.The short circuit breaking capacity is the total branch circuit supply current that the device can safely protect. Fields marked
with an asterisk indicate that the device can safely handle any supply current with output fusing. Appendix
Note 2: The trip currents and back-up fuses are per IEC 60947. Local codes and regulations may require
additional short circuit protection. Consult codes applicable to your application. Product
Index
Part #
Index
Volume 13
Motor Contactor and Motor Starter/Protector (MSP) Selection Guide (when motor FLA is known)
A B C
Current Range Motor Starter/Protector IEC Frame Size Special Assembly Note
Motor FLA Contactor Model Part Number
0.1 to 0.16 A MS25-16
0.16 to 0.25 A MS25-25
0.25 to 0.4 A MS25-40
0.4 to 0.63 A MS25-63
0.63 to 1 A MS25-100
GH15BN Up to 9A FLA
0.1 to 1.6 A MS25-160
Note: A DIN rail adapter plate is needed for assembly of the
1.6 to 2.5 A MS25-250 contactor and motor starter/protector. This plate allows two
45 mm frame size
2.5 to 4 A MS25-400 DIN rail devices to be mounted together as an assembly to
one piece of DIN rail. The part number is UMP45.
4 to 6.3 A MS25-630
6.3 to 10 A MS25-1000
10.0 to 16 A GH15CN Up to 12 A FLA MS25-1600
10.0 to 16.0 A GH15DN Up to 16A FLA MS25-1600
16.0 to 20.0 A MS25-2000
GH15ET Up to 25A FLA
20.0 to 25.0 A MS25-2500
The following charts are to be used as a guideline only. Motor control devices should be sized using the motor FLA (full load amperage) rat-
ing. It is the user’s responsibility to size the motor starter/protector properly.
Step 1: Select your motor horsepower rating in column A based on the rating from the motor data plate or spec. sheet.
Step 2: Go to column B to find your contactor model. Check the maximum amperage rating for that contactor. Ranges overlap and you may need to go
to the next larger size.
Step 3: After selecting your contactor, go to column C to find your motor starter/protector.
Motor Contactor and MSP Selection Guide for 440-480 Volt Three-Phase Motor Control
A B C
Motor Motor Starter/Protector IEC Frame Size Special Assembly Note
Horsepower Contactor Model Part Number
1/2 MS25-160
3/4 MS25-160
1 MS25-250
1 1/2 GH15BN Up to 9A FLA MS25-400
Note: A DIN rail adapter plate is needed for assembly of the
2 MS25-400 contactor and motor starter/protector. This plate allows two
45 mm frame size DIN rail devices to be mounted together as an assembly to
3 MS25-630 one piece of DIN rail. The part number is UMP45.
5 MS25-1000
7 1/2 GH15CN Up to 12A FLA MS25-1600
10 GH15DN Up to 16A FLA MS25-1600
15 GH15ET Up to 25A FLA MS25-2500
Motor Contactor and MSP Selection Guide for 230-240 Volt Three-Phase Motor Control
A B C
Motor Motor Starter/Protector IEC Frame Size Special Assembly Note
Horsepower Contactor Model art Number
1/2 MS25-250
3/4 MS25-400
1 GH15BN Up to 9A FLA MS25-400
Note: A DIN rail adapter plate is needed for assembly of the
1 1/2 MS25-630 contactor and motor starter/protector. This plate allows two
45 mm frame size DIN rail devices to be mounted together as an assembly to
2 MS25-1000 one piece of DIN rail. The part number is UMP45
3 GH15CN Up to 12A FLA MS25-1000
5 GH15DN Up to 16A FLA MS25-1600
7 1/2 GH15ET Up to 25A FLA MS25-2500
Volume 13
Systems
Overview
Starter/contactor Programmable
Controllers
features and
specifications Field I/O
Software
• EN60947-4-1 IEC 947-4-1 compliance
(international standard for low voltage C-more &
other HMI
switchgear and control devices)
• UL-listed and CSA-certified Drives
• 45 mm frame rated maximum 20 hp at
460V; highest horsepower rating in a Soft
Starters
compact, space-saving design
• Long-life twin break, silver cadmium Motors &
oxide contacts for excellent conductivity Gearbox
control applications.
Encoders
• Contactor and terminal markings conform
to CENELEC EN50011. Current
Sensors
• Holding circuit contact(s) supplied
Cutler-Hammer’s Freedom series of IEC standard Pressure
contactors feature a compact space
Starter overview • Lugs supplied standard on sizes A-F Sensors
saving design. The Cutler-Hammer AE16 Series IEC • Tape wound coil
Temperature
starters are full voltage magnetic starters • Straight-through wiring Sensors
Components that meet IEC 60947 are
more reliable, of higher quality, and are used for starting polyphase induction Pushbuttons/
better matched to their intended applica- motors. These starters also provide Lights
Tools
Pneumatics
Appendix
Product
Index
Part #
Index
Volume 13
1
Black/White
cold start 98
• Selectable manual or automatic reset (seconds)
operations 97
Systems
Overview
Heater packs are used with the H2007B-3 <---> 32 2.15 2.60 3.04 3.49 Motors &
Gearbox
C306DN3B overload relay. The load lugs
are built into the overload base to allow H2008B-3 <---> 32 3.23 3.90 4.56 5.23
Steppers/
load wiring prior to heater pack installa- H2009B-3 <---> 32 4.55 5.50 6.45 7.40 Servos
tion. Heater packs come in packs of H2010B-3 <---> 32 6.75 8.17 9.58 11.0 Motor
three. Controls
H2011B-3 <---> 32 9.14 10.8 12.4 14.0
H2012B-3 <---> 32 14.0 16.9 19.9 22.8 Proximity
Sensors
H2013B-3 <---> 32 18.7 22.7 26.7 30.7
Photo
H2014B-3 <---> 32 23.5 28.5 33.5 38.5 Sensors
The bifurcated (i.e. contact is split into two 10E indicates a contactor with one N.O.
and no N.C. auxiliary contacts (factory C306TB1 <---> Mounting Adapter for 32 Amp Relays/
fingers for redundant contact) design of Overload Relay Timers
Tools
Pneumatics
Auxiliary Contacts
Appendix
Part Number Price Description
C320KGS3 <---> 1 N.O. and 1 N.C. Product
Index
Auxiliary Contacts
C320KGS1 <---> 1 N.O.
Part #
Index
Volume 13
Average Coil Power Requirements / Coil current (A) = VA/Coil Voltage A.C. Pick-Up (VA) 80-100 / A.C. Sealed (VA) 7.5-10 Proximity
Power Factor Pick-Up .65 / Sealed .35 Sensors
Coil Operating Time at Rated Coil Voltage Pick-Up (ms) 12 / Drop-Out (ms) 12 Photo
Sensors
Maximum Operating Frequency (No-Load Operation) Pick-Up (ms) 12 / Drop-Out (ms) 12
Mechanical Durability 10,000,000 Operations Limit
Switches
Electrical Durability in Operations (AC3) note 1 2,000,000 2,000,000 2,220,222 1,300,000 1,600,000 1,500,000
Operating Ambient Temperature -25° to +55°C Encoders
Electrical Protection Degree IP20 (IP10 for AE16DN,AE16EN, AE15FN)
Current
Mounting Screw or 35mm DIN Rail Sensors
Line / Load #12 - 16 AWG stranded recommended #16 - #8 stranded recommended
Wire Sizes Pressure
Control & Auxiliary Contacts #12 - #14 AWG (stranded recommended) Sensors
IEC FRAME Hammer Part Number Price Auxiliary Contacts Coil Voltage and Terminal
SIZE Contactor Main Included Frequency Maximum Contact Block Type of Additional Contact Blocks &
Model Arrangement Block Wiring
N.0 N.C.
AE16ANS0AC <---> 3 1 110-120VAC 50-60Hz Power
AE16AN
AE16ANS0BC <---> 3 1 220-240VAC 50-60Hz
Circuit
AE16BNS0AC <---> 3 1 110-120VAC 50-60Hz Protection
AE16BN
AE16BNS0BC <---> 3 1 220-240VAC 50-60Hz Enclosures
AE16CNS0AC <---> 3 1 110-120VAC 50-60Hz
AE16CN Up to two auxiliary contact Side mount Tools
AE16CNS0BC <---> 3 1 220-240VAC 50-60Hz
45 mm blocks may be added to AE16 C320KGS3 (1 NO and 1 NC)
AE16DNS0AC <---> 3 1 110-120VAC 50-60Hz contactors (one per side). C320KGS1 (1 NO and 1 NC) Pneumatics
AE16DN
AE16DNS0BC <---> 3 1 220-240VAC 50-60Hz
Appendix
AE16ENS0AC <---> 3 1 110-120VAC 50-60Hz
AE16EN
AE16ENS0BC <---> 3 1 220-240VAC 50-60Hz Product
Index
AE16FNS0AC <---> 3 1 110-120VAC 50-60Hz
AE16FN
AE16FNS0BC <---> 3 1 220-240VAC 50-60Hz Part #
Index
Note: Holding circuit contact(s) supplied standard: a N.O. auxiliary contact block is mounted on the right-hand side. (On Sizes A-C, contact occupies fourth power pole
position-no increase in width.)
Volume 13
Top Side
AUX
AUX
Mount Mount
not Aux.
avail.
Auxiliary
Mounting holes for
contacts
M4 or #8 screws
Top Side
AUX Mount
AUX
not
Mount
available Aux.
Auxiliary
contacts
Mounting. holes for
M4 or #8 screws
Volume 13
Systems
Overview
Motor Current Ratings Programmable
Controllers
Full Load Ampere (FLA) Rating for AC Induction Motors
115 VAC 200 VAC 230 VAC 460 VAC
Motor HP Field I/O
1-Phase (A) 3-Phase (A) 1-Phase (A) 3-Phase (A) 1-Phase (A) 3-Phase (A) 3-Phase (A)
1/10 3.0 --- --- --- 1.5 --- --- Software
NEMA Mechanical Switching Ratings and Test Values for DC Control Temperature
Control Circuit Contact Circuit Contacts Sensors
Electrical Ratings Contact Thermal Maximum Make or Break DC Current (A) Pushbuttons/
Rating Continuous Lights
Desig- Test Current 125 Volts 250 Volts 301 to 600 Volts Voltamperes
nation (A) Process
P300 5.0 1.1 0.55 --- 138
Relays/
P600 5.0 1.1 0.55 0.20 138 Timers
NEMA Mechanical Switching Ratings and Test Values for AC Control Circuit Contacts Circuit
Protection
Contact Thermal Maximum AC Current, 50/60Hz (A)
Rating Continuous 120 Volts Voltamperes Enclosures
Desig- Test Current 240 Volts 480 Volts 600 Volts
nation (A) Tools
Make Break Make Break Make Break Make Break Make Break
A300 10 60 6.00 30 3.00 --- --- --- --- 7200 720 Pneumatics
A600 10 60 6.00 30 3.00 15 1.50 12 1.20 7200 720
Appendix
B300 5 30 3.00 15 1.50 --- --- --- --- 3600 360
B600 5 30 3.00 15 1.50 7.5 0.75 6 0.60 3600 360 Product
Index
C600 2.5 15 1.5 7.5 0.75 3.75 0.375 3.00 0.30 1800 180
This chart is provided as a guideline only, and the ratings and values are not guaranteed to be accurate. It is the users’ responsibility to properly size their control circuit Part #
devices. The chart values are from NEMA Standard ICS 5-2000, Table 1-4-1. Index
Volume 13
Volume 13
Disconnects Systems
Overview
Overview Programmable
Controllers
Bryant motor controllers are “suitable as motor disconnects,”
which means that a motor controller marked as such can also Field I/O
be used as a motor disconnect. From a safety perspective, this
means a motor load can now be isolated and locked-out in one Software
convenient location. By utilizing Bryant’s compact motor
C-more &
controllers and disconnects, you benefit through the conve- other HMI
nience of one device fulfilling two needs. A motor controller is
simply used to activate a motor load “ON” or “OFF” and Drives
compact package.
Limit
Switches
Encoders
Current
Sensors
• Thermoset body provides high • Can be used locally at the motor • UL Listed and Recognized Temperature
resistance to electrical arc tracking. • “Suitable as a motor disconnect” Catagory NLRV, UL file #E70402 Sensors
• Silver alloy contacts for excellent • Across-the-line motor starting • CSA Certified File 46186 Pushbuttons/
conductivity and extended life • Flammability - UL94HB/V
Lights
• Industrial machines
• Available NEMA 1, 3/3R and 4X • Standards Process
• Automation
enclosures UL508
• Switch contacts AC rated only Relays/
• Undrilled enclosures available for UL60947-1 Timers
(not DC rated).
custom placement of entry positions CSA C22.2 No 14
Comm.
• Lockout / Tagout capability
• Switch sizes in 30, 40 and 60 Amps up Terminal
Blocks &
to 600 VAC Wiring
Part #
Index
Volume 13
30002D 4002* Switch only, 40A, 2-pole, 5 HP @ 600 VAC - Standard Toggle 40 1 2 Side <--->
40003D
40002D Switch only, 40A, 2-pole, 15 HP @ 600 VAC - Standard Toggle 40 1 2 Side <--->
40003D Switch only, 40A, 3-pole, 20 HP @ 600 VAC - Standard Toggle 40 3 3 Side <--->
60002D Switch only, 60A, 2-pole, 20 HP @ 600 VAC - Standard Toggle 60 1 2 Back <--->
60003D Switch only, 60A, 3-pole, 30 HP @ 600 VAC - Standard Toggle 60 3 3 Back <--->
*Motor controller only (“Not suitable as disconnect”)
Example
Back and Side Wired Back Side
Wired Wired
30102D, 30322D,
Enclosed Toggle Switch AC Motor Controllers / Disconnects
30103D 30323D Part
Number Description Included Switch Amperage Phase Poles Enclosure Price
30102D Enclosed, 30A, 2-pole, NEMA 1 30002D Standard Toggle 30 1 2 NEMA 1 <--->
30103D Enclosed, 30A, 3-pole,NEMA 1 30003D Standard Toggle 30 3 3 Metal <--->
30302D Enclosed, 30A, 2-pole, Aluminum 30002D Standard Toggle 30 1 2 NEMA 3R <--->
30303D Enclosed, 30A, 3-pole, Aluminum 30003D Standard Toggle 30 3 3 Metal <--->
30322D* Enclosed, 30A, 2-pole, Plastic 30002DS Short Toggle 30 1 2 NEMA 3R <--->
30323D* Enclosed, 30A, 3-pole, Plastic 30003DS Short Toggle 30 3 2 Thermoplastic <--->
30302D, 60302D* Enclosed, 60A, 2-pole, Aluminum 60002FWD Standard Toggle 60 1 2 <--->
NEMA 3R
30303D 60303D* Enclosed, 60A, 3-pole, Aluminum 60003FWD Standard Toggle 60 3 3 Metal <--->
*Switch is not available as a separate item
60302D,
60303D
NEMA 4X Enclosed Rotary Switch AC Motor Controllers / Disconnects
Part
Number Description Included Switch Amperage Phase Poles Enclosure Price
664X33D* Enclosed, 30A, 3-pole, NEMA 4X 66033D Rotary 30 3 3 NEMA 4X <--->
664X63D* Enclosed, 60A, 3-pole, NEMA 4X 66033D Rotary 60 3 3 Thermoplastic <--->
*Switch is not available as a separate item
6610MK Rotary handle replacement kit, use with 664X33D and 664X63D. (Nema 1 rating) Must use gasket replacement kit <--->
664XWP for NEMA 4X rating.
NEMA 4X enclosure gasket replacement kit; includes 4 seals, neoprene bushing and 3 o-rings; use with 664X33D and
664XWP 664X63D
<--->
Toggle AC manual motor controllers can be integrated into your equiment design as a Programmable
Controllers
manual motor controller or as a motor disconnect. Quick-make and slow break operation
provides reliability and long life. Each toggle switch controller has a 10,000 amp high fault
short circuit withstand rating. Field I/O
Proximity
Sensors
Current
Sensors
Pressure
Sensors
Temperature
Optional side guard for Sensors
close wall applications and
Pushbuttons/
finger safe environment Lights
Process
Relays/
Timers
30003FG Comm.
Terminal
Blocks &
40002D Wiring
Enclosures
Tools
Product
Index
Part #
Index
60003D
Volume 13
4002
30003FG
30100
Dimensions
Units: inches [mm]
60002D
4002
60002D, 60003D,
Volume 13
Enclosed toggle AC manual motor controllers feature NEMA 1 or NEMA 3R enclosures and Programmable
Controllers
can be used as motor controllers or disconnects. The NEMA 1 metal enclosed switches are
ideal for use in indoor enviroments. The thermoplastic and metal NEMA 3R enclosed switches
are raintight for use outdoors. Field I/O
30103D Steppers/
NEMA 3 / 3R Motor Controllers / Disconnects Servos
• Raintight enclosures
• Designed for surface mounting Motor
Controls
Encoders
Current
Sensors
Lockout / Tagout
capability Pressure
Sensors
Pushbuttons/
Lights
Process
Rain tight drip
shield top; rolled
seamless sides All aluminum cover and Relays/
base; base is pre-drilled Timers
for rear surface mounting
Comm.
All aluminum cover and
base; base is pre-drilled Terminal
Blocks &
for rear surface mounting Wiring
Power
Circuit
Protection
30102D, 30103D
Programmable
Controllers
Dimensions
Units: inches [mm] Field I/O
Software
C-more &
other HMI
Drives
Soft
Starters
Motors &
Gearbox
Steppers/
Servos
Motor
Controls
Proximity
Sensors
Photo
Sensors
Limit
Switches
30302D, 30303D
Encoders
Current
Sensors
Pressure
Sensors
Temperature
Sensors
Pushbuttons/
Lights
Process
Relays/
Timers
Comm.
Terminal
Blocks &
Wiring
Power
Circuit
Protection
Enclosures
Tools
Pneumatics
Appendix
60302D, 60303D
Product
Index
Part #
Index
Volume 13
Wire bending
Undrilled case space for drip
allows custom loops
placement of
entry positions
with normal tools Accessible front
and knockouts wiring termination
Interlocking shaft
handle assembly
prevents cover
Clearly identified removal when in
“ON / OFF” the “ON” position
indicators
660AC* SPDT Auxiliary contact NO / NC. includes one contact for use with push-on terminals, use with 664X33D <--->
and 664X63D Motors &
Gearbox
6610MK Rotary handle replacement kit, use with 664X33D and 664X63D (Nema 1 rating) Must use gasket <--->
replacement kit 664XWP for NEMA 4X rating.
664X33D Steppers/
NEMA 4X enclosure gasket replacement kit; includes 4 seals, neoprene bushing and 3 o-rings; use with
664XWP 664X33D and 664X63D
<---> Servos
Photo
Sensors
Limit
Switches
Encoders
660AC 6610MK
30003FG Current
Sensors
Pressure
Sensors
Temperature
Sensors
664XFT 6603N
664XWP Pushbuttons/
Lights
664X63D
Process
Terminal
Blocks &
Wiring
Power
Circuit
Protection
Enclosures
Tools
Pneumatics
Appendix
Product
Index
664X33D
Part #
Index
664X63D
Volume 13
General Specifications
Type Part Weight Short Circuit Dielectric Electrical Max Working Mechanical Operating
Number Withstand Rating Voltage Life Voltage Life Temperature
30002D 0.4 lbs (181 g)
30003D 0.5 lbs (227 g)
10 kA
4002 0.1 lbs (45 g) 60A max J fuses
Standard or 125A max RK5 fuses
Toggle Switch 40002D
0.4 lbs (181 g)
40003D 0.5 lbs (227 g)
60002D 10 kA
0.7 lbs (318 g) 80A max J fuses
60003D or 125A max RK5 fuses
30102D
1.0 lbs (454 g) 2,200V AC minimum 6,000 cycles at 10,000 minimum -40 °C (-40 °F)
30103D for 1 minute rated switch load 600 VAC RMS cycles to 60 °C (140 °F)
30302D 10 kA
1.3 lbs (590 g) 60A max J fuses
Enclosed 30303D or 125A max RK5 fuses
Toggle Switch 30322D
2.2 lbs (998 g)
30323D
60302D 1.9 lbs (861 g)
60303D 2.0 lbs (907 g) 10 kA
80A max J fuses
Enclosed 664X33D 2.5 lbs (1,134 g) or 125A max RK5 fuses
Rotary Switch 664X63D 3.0 lbs (1,361 g)
NC
660AC SPDT 15A @ 250 VAC Resistive, 10A @ 250 VAC Inductive Silver Alloy
NO 10A @ 30VDC Resistive and Inductive
COM
Wiring Specifications
Type Part Number Cable Size Tightening Torque
30002D
14 to 10 AWG 2.5 to 6 mm2
30003D
4002 20 lb-in 2.3 Nm
Toggle Switch 40002D 14 to 8 AWG 2.5 to 10 mm2
40003D
60002D
14 to 6 AWG 2.5 to 16 mm2 25 lb-in 2.8 Nm
60003D
30102D
30103D
30302D
14 to 10 AWG 2.5 to 6 mm2 20 lb-in 2.3 Nm
Enclosed 30303D
Toggle Switch 30322D
30323D
60302D
60303D
14 to 6 AWG 2.5 to 16 mm2 25 lb-in 2.8 Nm
Enclose Rotary 664X33D
Switch 664X63D
Note: Bryant does not recommend the use of wire ferrules or crimping terminals. The wire gauges
are specified above and in the installation instructions included with each manual motor controller.
Volume 13
Reference Guide
The reference guide below provides general information on the different versions of Phase Monitor Relays offered by
AutomationDirect.com (see Product Selection on the following pages for further details).
Volume 13
Systems
Overview
Features
PMRU PMRR • Compact plug-in case utilizing industry- Programmable
Controllers
• Universal voltage range of 208 to 480VAC, • Protects against phase reversal standard 8-pin octal socket
3-phase systems • Works with 208-480V 3-phase systems • 10A SPDT output contacts
Field I/O
• Protects against phase loss, phase • LED indicates both normal and fault
reversal, phase unbalance, undervoltage conditions
and overvoltage • Compact plug-in case utilizing industry-
Agency Approvals Software
Motor
Controls
ProSense Series Phase Monitor Relays
Part Number Description Pcs/Pkg Wt (lb) Price Use With Proximity
Sensors
Phase monitor relay, provides protection against phase reversal, phase loss, phase unbalance, 70169-D or
PMRU-1C-480A* undervoltage, and overvoltage; 10A SPDT output contacts, 8-pin octal base. Works with 3-phase 1 0.4 <--->
750-2C-SKT Photo
systems from 208V to 480V. Sensors
Phase monitor relay, provides protection against phase reversal; 10A SPDT output contacts, 8-pin 70169-D or
PMRR-1C-480A* octal base. Works with 3-phase systems from 208V to 480V.
1 0.3 <--->
750-2C-SKT Limit
70169-D or Switches
Phase monitor relay, provides protection against phase reversal, phase loss and undervoltage; 10A
PMRRL-1C-208A SPDT output contacts, 8-pin octal base. Works with 208V 3-phase systems.
1 0.3 <--->
750-2C-SKT
Encoders
Phase monitor relay, provides protection against phase reversal, phase loss and undervoltage; 10A 70169-D or
PMRRL-1C-240A SPDT output contacts, 8-pin octal base. Works with 240V 3-phase systems.
1 0.3 <--->
750-2C-SKT
Current
Phase monitor relay, provides protection against phase reversal, phase loss and undervoltage; 10A 70169-D or
PMRRL-1C-480A* SPDT output contacts, 8-pin octal base. Works with 480V 3-phase systems.
1 0.3 <--->
750-2C-SKT
Sensors
Relay socket, 10A at 600V, 8-pin octal configuration. Can be mounted on 35mm DIN rail or directly Pressure
70169-D mounted to the panel.
1 0.1 <---> -----
Sensors
Relay socket, 5A at 600V, 8-pin octal configuration. Can be mounted on 35mm DIN rail or directly
750-2C-SKT mounted to the panel.
1 0.1 <---> ----- Temperature
Sensors
* Requires a 600V socket when used on system voltages greater than 300 volts, such as the 70169-D or 750-2C-SKT
Pushbuttons/
Technical Specifications Lights
PMRU-1C-480A PMRR-1C-480A PMRRL-1C-208A PMRRL-1C-240A PMRRL-1C-480A
Process
Input Voltage Range** 208-480 VAC 50/60Hz (+/-20%) 208-480 VAC 208 VAC 240 VAC 480 VAC
50/60Hz (+10/-25%) 50/60Hz (+10/-25%) 50/60Hz (+10/-25%) 50/60Hz (+10/-25%)
Relays/
Phase Loss Unit trips on total loss of one or more of the three phases N/A Unit trips on total loss of one or more of the three phases (A,B,C) Timers
(A,B,C)
Unit trips if sequence of the three phases is anything other N/A Comm.
Phase Reversal than A-B-C Unit trips if sequence of the three phases is anything other than A-B-C
Terminal
Phase Unbalance Adjustable from 2 to 10% N/A Blocks &
Wiring
Undervoltage Adjustable from 80 to 95%of nominal voltage N/A Unit trips when the average of all three line phases is less than the adjusted
set point*
Power
Overvoltage Fixed at 110% of Nominal N/A N/A N/A N/A
Output Contacts SPDT: 10A at 240 VAC/30 VDC Max SPDT: 10A at 240 VAC Max Circuit
Protection
Life* Mechanical: 10,000,000 Electrical: 100,000 Mechanical: 100,000 Electrical: 100,000
Response Times See table 2 on page e4 Pick-up: 50ms, Drop out: 50ms Enclosures
Power Consumption 3 VA
Temperature -28° to 65°C (-18 to 149°F) Tools
Mounting 8-pin octal socket requires a 600 V rated socket when used on system voltages greater than 300 V
Pneumatics
Indicator LED See table 1 on page e4 Red LED on when all conditions are normal and off when a fault condition has occurred
Standard reset is automatic upon correction of fault or when Appendix
Reset a momentary-contact N.C. switch is wired across the Standard reset is automatic upon correction of fault.
Manual Reset terminals (6 & 7), the unit switches to
manual reset mode and remote manual reset is available Product
Index
Approvals cURus, CE (PMRU series only), RoHS, (cULus when used with socket 70169-D)
* Resistive load Part #
Index
** Fusing is not required by code but if fusing is used we recommend 2 Ampere MCL2 fuse between the phase monitor relay and the three phases.
Volume 13
9
8
Time Delay (seconds)
7
6
5
4
3
2
1
0
% % % % % % % % % % %
10 12 14 16 18 20 22 24 26 28 30
% Overvoltage
Volume 13
Systems
Overview
Programmable
Wiring and Dimensions Controllers
Software
C-more &
other HMI
2.39
[60.8] Drives
Soft
Starters
Motor
Controls
Proximity
Sensors
PMRR-1C-480A Photo
Sensors
Limit
Switches
Encoders
2.39
[60.8] Current
Sensors
Pressure
Sensors
2.90
[73.8]
Temperature
1.70 Sensors
3.10
[43.1] [78.4]
Pushbuttons/
Lights
Process
Relays/
Timers
Comm.
PMRRL-1C-208A, PMRRL-1C-240A, PMRRL-1C-480A
Terminal
Blocks &
Wiring
Power
2.39
[60.8] Circuit
Protection
Enclosures
2.90 Tools
[73.8]
Appendix
Volume 13
Typical Connections
Line Side Monitoring
Volume 13
Systems
Overview
Programmable
Controllers
Field I/O
Software
C-more &
other HMI
Drives
AR ARX
Soft
Starters
Alternating Relays Motors &
Gearbox
AR Series ARX Series
Alternating relays are used in special applications where the opti- Alternating relays with DPDT cross-wired outputs are used in Steppers/
Servos
mization of load usage is required by equalizing the run time of applications requiring both (a) the optimization of load usage by
two loads. The alternating action is initiated by a control switch, equalizing the run time of two loads and (b) additional capacity Motor
such as a float switch, manual switch, timing delay, pressure in case of excess load requirements. The alternating action is Controls
switch, or other isolated contact. Each time the initiating switch is initiated by a control switch, such as a float switch, manual switch, Proximity
opened, the output relay contacts will change state, thus timing relay, pressure switch, or other isolated contact. Each time Sensors
alternating the two loads. Two LED indicators show which load to the initiating switch is opened, the output relay contacts will
Photo
energize next. change state, thus alternating the two loads. Two LED indicators Sensors
The alternating relay can be used with one or two control switches show the load to energize first.
Limit
and is available in the SPDT output configuration. Alternating relays with DPDT cross-wired output configurations Switches
The AR Series Relays have a three-position selector switch. This can be used with two or three control switches.
Encoders
allows the unit to alternate the two loads as normal, or lock the The ARX series relays have a three-position selector switch. This
relay to one load or the other. By locking the alternating relay to allows a DPDT cross-wired unit to alternate the two loads as Current
one load, the other load can be removed for service without normal, or lock the relay to always operate the same load first Sensors
rewiring the first load for continuous operation. The selector each time. In this manner, a load that has fewer hours of Pressure
switch has a low profile to prevent any accidental changes in operation than the other load could be used more often in an Sensors
status. effort to eventually balance the run time of both loads.
Temperature
Sensors
Pushbuttons/
Lights
Features Process
AR ARX
Relays/
• For duplex loads • For duplex loads Timers
• 10A SPDT output configuration • 10A DPDT cross-wired output configuration
• Can be used with one or two control switches • Can be used with two or three control switches Comm.
Product
Index
Part #
Index
Volume 13
Alternating relay, for use in applications requiring load usage optimization by equalizing the run
time of two loads, accomodates additional capacity in case of excess load requirements. 120 70169-D or
ARX-2C-120A VAC coil voltage, DPDT Cross Wired, 10A contact rating, 8-pin octal base, selector switch to
1 0.3 <--->
750-2C-SKT
select between load A, load B, or alternate loads. Two LEDs indicate load to energize first.
Relay socket, 10A at 600V, 8-pin octal configuration. Can be mounted on 35mm DIN rail or
70169-D directly mounted to the panel.
1 0.1 <---> -----
Relay socket, 5A at 600V, 8-pin octal configuration. Can be mounted on 35mm DIN rail or
750-2C-SKT directly mounted to the panel.
1 0.1 <---> -----
Technical Specifications
AR-1C-120A ARX-2C-120A
Voltage Tolerances 120 VAC 50/60Hz (+10%/-15%)
Output Contacts 10A at 240 VAC/30 VDC Max
Life* Mechanical 10,000,000 operations; Electrical - Resistive: 100,000 operations
Power Consumption Less than 3 VA
Temperature -28 to 65°C (-18 to 149°F)
Mounting 8-pin octal socket
Indicator LED 2 LEDs marked LOAD A and LOAD B
LOCK LOAD A LOCK LOAD A (Always energizes first based on switch position)
Selector Switch Settings ALTERNATE ALTERNATE
LOCK LOAD B LOCK LOAD B (Always energizes first based on switch position)
Approvals cURus, CE, CSA (LR45565), RoHS, (cULus when used with socket 70169-D)
* Resistive load
Wiring
AR-1C-120A ARX-2C-120A
Dimensions
AR-1C-120A, ARX-2C-120A
2.39
[60.8]
2.90
[73.8]
3.10
1.70 [78.4]
[43.1] All Dimensions in
Inches (Millimeters)
Volume 13
Systems
Typical Installations Overview
When using the AR series relay with the selector switch in the Control Switch closes again, it energizes Load M2. When the Programmable
Controllers
“Alternate” position in the initial off state (Figure A), the Control Control Switch opens, Load M2 is turned off, the Alternating
Switch is open, the Alternating Relay is in the “LOAD A” posi- Relay toggles back to the “LOAD A” position, and the process
Field I/O
tion, and both loads (M1 and M2) are off. The red LED marked can be repeated again. On relays with DPDT contacts, two pilot
“LOAD A” is ON. When the Control Switch closes, it energizes lights can be used for remote indication of “LOAD A” or “LOAD Software
Load M1. As long as the Control Switch remains closed, Load B” status.
M1 remains energized. When the Control Switch opens, Load To eliminate any bounce condition of the Control Switch, the C-more &
other HMI
M1 is turned off and the Alternating Relay toggles to the “LOAD addition of a second switch (OFF) along with two auxiliary
B” position. The red LED marked “LOAD B” glows. When the contacts is recommended as shown (Figure B). Drives
L1 L2 Soft
Starters
M2 O/L
Motors &
M2 Gearbox
L1 L2 M1 O/L
Steppers/
M1 Servos
O/L
2
1 M1 2 Motor
Control 1 Controls
O/L Control
Switch OFF Switch
5 8 M2 Proximity
5 8 Sensors
Photo
4 3 Sensors
4 3
Limit
Switches
Figure A Figure B
Encoders
When using the ARX series relay with the selector switch in the A type of operation known as “Sequence On - Simultaneously Off
“Alternate” position in the initial off state (Figure C), both the (S.O.S.O.)” where the two loads are energized sequentially, but Current
Sensors
LEAD Control Switch and the LAG Control Switch are open, the remain on together until the OFF switch is opened (Figure D). In
Alternating Relay is in the “LOAD A” position, and both loads are the initial OFF state, all three switches are open, the Alternating Pressure
Sensors
off. The red LED marked “LOAD A” is ON. When the LEAD Relay is in the “LOAD A” position, and both loads are off. No
Control Switch closes, it energizes Load M1. As long as the LEAD action happens with the Alternating Relay or either load when the Temperature
Control Switch remains closed, Load M1 remains energized. If the OFF Switch closes. When the LEAD Switch closes, Load M1 turns Sensors
LAG Control Switch closes, it energizes Load M2. When the LAG on. When the LAG Switch closes, Load M2 turns on. Both loads
Pushbuttons/
Control Switch opens, Load M2 is turned off. When the LEAD remain on as long as all three switches are closed. When the LAG Lights
Control Switch opens, Load M1 is turned off And the Alternating Switch opens, Load M2 remains on because the OFF Switch is still
Process
Relay toggles to the “LOAD B” position. The red LED marked closed. When the LEAD Switch opens, Load M1 remains on
“LOAD B” is ON. When the LEAD Control Switch closes, it turns because the STOP Switch is still closed. When the OFF Switch Relays/
on Load M2. If the LAG Control Switch closes, it will energize opens, both Load M1 and Load M2 are turned off simultaneously. Timers
Load M1. When the LAG Control Switch opens, Load M1 is The Alternating Relay toggles to the “LOAD B” position. The entire
Comm.
turned off. When the LEAD Control Switch opens, Load M2 is cycle is then repeated, but with Load M2 energized first followed
turned off, the Alternating Relay toggles back to the “LOAD A” by Load M1. Terminal
position, and the process can be repeated again. Blocks &
Wiring
L1 L2
M2 O/L Power
M2
Circuit
M1 O/L Protection
M1
L1 L2 Enclosures
Lag 2 Lag
O/L 2 Tools
8 8
M1
Pneumatics
Lead O/L Lead
1 OFF 1
7 M2 7 Appendix
Product
3 6 3 6 Index
Part #
Figure C Index
Figure D
Note: M1 and M2 reference in Figures A,B,C and D are coils.
Volume 13
PSFR PSFR-2C
Pump Seal Failure Relays
PSFR Series When the resistance drops below the user-adjustable sensitivity
PSFR series pump failure relays are designed to monitor the shaft setpoint of the relay, the output relay energizes and the LED turns
seals of submersible pumps. A resistive-measuring probe is ON. The relay output can be used to give an alarm indication of
installed in the pump seal cavity provided by pump manufacturer. a leaking seal. These products will automatically reset when the
If the seal starts to leak, contaminating fluid enters the seal cavity fault condition clears.
provided by pump manufacturer, lowering the resistance between Two pump seal failure relays are available:
the internal probe and the common connection. 1.) 8-pin SPDT single channel relay
2.) 8-pin dual channel relay, with 2 SPNO contacts
Features
• Monitors submersible pump seals for leakage Agency Approvals
• Single or dual channel for monitoring one or two pumps • cURus, File number E191059
• Adjustable sensitivity ranges (4.7K, 20K, 47K, 100K) • CE, EN60947-1, EN60947-5-1
• Uses industry-standard 8-pin octal sockets • RoHS
(with appropriate
socket 70169-D)
Pump seal failure relay, monitors shaft seals of submersible pumps. Dual channel, adjustable sen- 70169-D or
PSFR-2C-120A sitivity range from 4.7K, 20K, 47K, 100K, LED failure indication, two 5A single-pole N.O. output 1 0.4 <--->
750-2C-SKT
contacts, 8-pin octal base, 9 VDC probe voltage.
Relay socket, 10A at 600 V rated, 8-pin octal configuration. Can be mounted on 35mm DIN rail or
70169-D directly mounted to the panel.
1 0.1 <---> -----
Relay socket, 5A at 600 V rated, 8-pin octal configuration. Can be mounted on 35mm DIN rail or
750-2C-SKT directly mounted to the panel.
1 0.1 <---> -----
Technical Specifications
PSFR-1C-120A PSFR-2C-120A
Voltage Tolerances 120 VAC 50/60Hz (+10%/-15%)
Output Contacts 10A at 240 VAC/30 VDC Max
Life* Mechanical 10,000,000 operations; Electrical: 100,000 operations
Probe Voltage 9 VDC
Response Time Pick-up: 10ms; Drop-out: 10ms
Power Consumption 2 VA
Temperature -28 to 65°C (-18 to 149°F)
Mounting 8-pin octal socket
Indicator LED Red ON when seal leak detected and relay energized
Systems
Overview
Programmable
Wiring Controllers
Software
C-more &
other HMI
Drives
Soft
Starters
Motors &
Gearbox
Steppers/
Servos
Motor
Controls
Dimensions
Proximity
PSFR-1C-120A, PSFR-2C-120A Sensors
Photo
Sensors
Current
Sensors
2.90
[73.8] Pressure
Sensors
1.70 3.20
[43.1] [81.3] All Dimensions in
Inches (Millimeters) Temperature
Sensors
Pushbuttons/
Lights
Typical Installations Process
ALARM 2
Relays/
Timers
Terminal
Blocks &
Wiring
PB1 PB2
COM COM
Power
COM COM
PROBE Circuit
4 5 PROBE 4 Protection
3 5 PROBE 1
3 6 6
PROBE 2
2 7 2 7 Enclosures
18 18 COM
Tools
L1 L2
L1
INPUT
L2 PSFR-1C-120A 120 VAC
INPUT PSFR-2C-120A
120VOLTAGE
VAC Pneumatics
Single Channel VOLTAGE Dual Channel
Appendix
Product
Index
Part #
Index
Volume 13
70169-D 750-2C-SKT
Features
• 600V (Plug-in 3-phase monitor relays require a 600V-rated socket Agency Approvals
when used with system voltages greater than 300V) • cURus, File number E191059, E225080
• Mounts on 35mm DINrail • CE
• Screw pressure wire clamp termination • RoHS
Technical Specifications
Part Number Voltage Current Screw Size Screw wire size (capacity) Screw wire torque Screw chassis
mounting torque
70169-D 600V 10A 6-32 1 or 2 #12-#22 AWB 6-7 Lb-in (12 Lb-in max) 7 Lb-in
750-2C-SKT 600V 5A M3.5 (1) #12/ (2) #14 AWG 9 Lb-in 7Lb-in
Dimensions
70169-D 750-2C-SKT
5 (22)
1.295
[32.89]
.580 6 (24) 1 (11)
[14.73]
4 (12)
2 1 8 7 8 (21)
3 (14)
2.010 2.160
[51.05] [54.86]
MADE
IN
Ø.165 USA 1.005
3 4 5 6
[Ø4.19] [25.53]
7 (A2)
2 (A1)
.312
[7.92]
Socket Pinouts
750-2C-SKT
70169-D
All Dimensions in
Inches (Millimeters)
Volume 13