Ervin Germany GMBH - Rudower Chaussee 48 - 12489 Berlin - Germany

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

PRODUCT CERTIFICATION REPORT

10.02.2021 G21-110 SO80121000089


Date Certification No. Ervin Order No.
TM
Metalcorp Eirl TMM-21-234 09.02.2021
Customer P.O. No. Shipping Date

SH80121000558
Attention Release No. Customer No.

Av. Proceres Mz B4 LT21 Urb. Puerta De Pro S-280


Address Product shipped

Los Olivos, Lima-Peru Peru


City State Postal code Country

S0280-S-YA 3,000t GC210209


Product Code Quantity Shipped *Manufacturing Date (lot#)

Specification(s) Certified to (including revision Date or Code): SAE J827, SAE J444

CERTIFICATION TEST RESULTS:

SIEVE ANALYSIS HARDNESS


MM Inches Specification Cumulative % Retained RC - Converted from Vickers 500 Grams
1,180 .0469 0% 0% Hardness Number
1,000 .0394 5% max 0% Specification 40-51 HRC - 90% min
0,710 .0278 85% min 98% # of readings 10
0,600 .0234 96% min 100%
Average 46
Range 6,2

CHEMICAL ANALYSIS MISCELLANEOUS TESTS


Element Specification Percent * Characteristic Specification Results
Carbon 0.80-1.20 0,90 Internal Defects 20% Max Less Than 20%
Manganese Cracks 15% Max Less Than 15%
S230 and up, 0.60-1.20 Hollows 10% Max Less Than 10%
and all Grit 0,81 Shrinkage 10% Max Less Than 10%
S170 0.50-1.20 Density 7.0 gr/ml Greater Than 7.0 gr/ml
S70-S110 0.35-1.20 Particle Shape (Elongation) 5% Max Less Than 5%
Silicon 0.40 Min. 0,78 Moisture 0.2% Max Less Than 0,2%
Sulphur 0.05 Max. 0,022
Phosphorous 0.05 Max. 0,019
Microstructure: Uniform tempered martensite with fine, well-distributed carbides.

COMMENTS: Product certification report is according DIN EN 10204 - 2.2

Signature: Title: Quality Assurance

Revised 15/05/20 ERVIN Germany GmbH - Rudower Chaussee 48 - 12489 Berlin - Germany C43-3

Page 1 of 2
1. This report is confidential and proprietary information for the customer requiring this report.

2. This report will not be copied and/or distributed outside of Ervin without written consent of the customer.

3. The following applicable test procedures we used to generate the data included in this report.

4. Ervin Amasteel complies to all the latest revisions for the specifications listed below.

SAE International:
SAE J442 Test Strip Holder and Gauge for Shot Peening
SAE J443 Procedures for Using Standard Shot Peening Test Strip
SAE J444 Cast Shot and Grit Size Specifications for Peening and Cleaning
SAE J445 Metallic Shot and Grit Mechanical Testing
SAE J827 Cast Steel Shot
SAE J1993 Cast Steel Grit
SAE AMS2431 Peening Media General Requirements
SAE AMS2431/1 Cast Steel Shot, Regular Hardness (45 - 52 HRC)
SAE AMS2431/2 Cast Steel Shot, High Hardness (55 - 62 HRC)

* ISO (International Organisation for Standardisation):


ISO 11125 Preparation of Steel Substrates Before Application of Paints and Related Products -
Test Methods for Blast Cleaning Abrasive.
Part 1: Sampling
Part 2: Determination of Particle Size Distribution
Part 3: Determination of Hardness
Part 4: Determination of apparent density
Part 5: Determination of percentage defective particles and of microstructure
Part 6: Determination of foreign matter
Part 7: Determination of moisture

ASTM:
B 215 Standard Practices for Sampling Finished lots of Metal Powders
D 512 Standard Test Method for Chloride Ion in Water
D 4940 Standard Test Method for Conductimetric Ionic Contamination of Blasting Abrasive
E 11 Specification for Wire Cloth Sieves for Test Purposes
E 140 Hardness Conversion Tables for Metals (Relationship between Brinell Hardness, Vickers
Hardness, Rockwell Hardness, Rockwell Superficial Hardness and Knoop Hardness
E 305 Standard Practice for Establishing and Controlling Spectrochemical Analytical Curves
E 384 Test Methods for Microhardness of Materials
E 406 Standard Practice for Using Controlled Atmospheres in Spectrochemical Analysis
E 415 Standard Test Method for Optical Emission Vacuum Spectrometric Analysis of Carbon
and Low Alloy Steel
E 1010 Standard Practice for Preparation of Disk Specimens of Steel and Iron for
Spectrochemical Analysis by Remelting
E 1257 Standard Guide for Evaluating Materials Used for Surface Preparation in
Spectrochemical Analysis

Ervin Amasteel Quality Instructions:


Q.I. No. - TL-5/GL-5 Durability Test
Q.I. No. - TL-43/GL-43 Transmitted Energy Test

Revised 06.05.2020 ERVIN Germany GmbH - Rudower Chaussee 48 - 12489 Berlin - Germany C43-9
Page 2 of 2