2-Wire Transmitter With HART Protocol: Application

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

2-wire transmitter with HART protocol

5337A
– RTD, TC, Ohm, and bipolar mV input
– 2 analog inputs and 5 device variables with status available
– HART protocol revision selectable from HART 5 or HART 7
– Hardware assessed for use in SIL applications
– Mounting in Safe area or Zone 2/22

Application
Applications
• Linearized temperature measurement with TC and RTD
sensors e.g. Pt100 and Ni100.
• HART communication and 4...20 mA analog PV output for
individual, difference or average temperature measurement of
up to two RTD or TC input sensors.
• Conversion of linear resistance to a standard analog current
signal, e.g from valves or Ohmic level sensors.
• Amplification of bipolar mV signals to standard 4...20 mA
current signals.
• Up to 63 transmitters (HART 7) can be connected in a
multidrop communication setup.

Technical characteristics
• HART protocol revision can be changed by user configuration
to either HART 5 or HART 7 protocol.
• The HART 7 protocol offers:∙ Long Tag numbers of up to 32
characters.∙ Enhanced Burst Mode and Event notification with
time stamping.∙ Device variable and status mapping to any
dynamic variable PV, SV, TV or QV.∙ Process signal trend
measurement with logs and summary data.∙ Automatic event
notification with time stamps.∙ Command aggregation for
higher communication efficiency.
• 5337A is designed according to strict safety requirements and
is therefore suitable for applications in SIL installations.
• Continuous check of vital stored data.
• Meeting the NAMUR NE21 recommendations, the 5337
HART transmitter ensures top measurement performance in
harsh EMC environments. Additionally, the 5337 meets
NAMUR NE43 and NE89 recommendations.

Mounting / installation
• For DIN form B sensor head or DIN rail mounting via the PR
fitting type 8421.
• Configuration via standard HART communication interfaces or
by PR 5909 Loop Link.

This page is automatically generated on the basis of information provided on www.prelectronics.com and affiliated websites. It is provided to you as a service and for information
purpose only. While we have attempted to maintain the information as accurately as possible, the page may contain errors or omissions for which we disclaim any and all liability
Environmental Conditions Sensor error indication................................... Programmable 3.5…23 mA
NAMUR NE43 Upscale/Downscale............... 23 mA / 3.5 mA
Operating temperature................................... -40°C to +85°C
Calibration temperature................................. 20...28°C Common output specifications
Relative humidity............................................ < 95% RH (non-cond.) Updating time................................................. 440 ms
Protection degree (encl./terminal).................. IP68 / IP00
HART protocol revisions................................ HART 7 and HART 5
Mechanical specifications
I.S. / Ex marking
Dimensions.................................................... Ø 44 x 20.2 mm
Weight approx................................................ 50 g ATEX.............................................................. II 3 G Ex nA [ic] IIC T4...T6
Gc, II 3 G Ex ic IIC T4...T6 Gc,
Wire size........................................................ 1 x 1.5 mm2 stranded wire II 3 D Ex ic IIIC Dc
Screw terminal torque.................................... 0.4 Nm IECEx............................................................. Ex nA [ic] IIC T4...T6 Gc, Ex ic
Vibration......................................................... IEC 60068-2-6 IIC T4...T6 Gc, Ex ic IIIC Dc
2...25 Hz......................................................... ±1.6 mm CSA................................................................ Cl. I, Div. 2, Gp. A, B, C, D
25...100 Hz..................................................... ±4 g T6...T4, Ex nA[ic] IIC T6…T4
Gc
Common specifications INMETRO....................................................... Ex nA [ic] IIC T6...T4 Gc, Ex ic
IIC T6...T4 Gc, Ex ic IIIC Dc
Supply
Supply voltage............................................... 8.0...35 VDC Observed authority requirements
Isolation voltage EMC............................................................... 2014/30/EU
Isolation voltage, test / ATEX.............................................................. 2014/34/EU
working........................................................... 1.5 kVAC / 50 VAC RoHS.............................................................. 2011/65/EU
EAC................................................................ TR-CU 020/2011
Response time EAC Ex........................................................... TR-CU 012/2011
Response time (programmable).................... 1...60 s
Voltage drop...................................................
8.0 VDC Approvals
Signal / noise ratio.........................................
> 60 dB DNV-GL Marine............................................. TAA0000101
Programming.................................................
Loop Link & HART ATEX.............................................................. KEMA 03ATEX1508 X
Accuracy........................................................
Better than 0.05% of selected IECEx............................................................. KEM 10.0083X
range CSA................................................................ 1125003
Signal dynamics, input................................... 22 bit INMETRO....................................................... DEKRA 18.0002X
Signal dynamics, output................................. 16 bit EAC Ex........................................................... RU C-DK.HA65.B.00355/19
EMC immunity influence................................ < ±0.1% of span SIL.................................................................. Hardware assessed for use in
Extended EMC immunity: NAMUR SIL applications
NE21, A criterion, burst.................................. < ±1% of span

Input specifications
Common input specifications
Max. offset...................................................... 50% of selected max. value

RTD input
RTD type........................................................ Pt50/100/200/500/1000;
Ni50/100/120/1000
Cable resistance per wire.............................. 5 Ω (up to 50 Ω per wire is
possible with reduced
measurement accuracy)
Sensor current............................................... Nom. 0.2 mA

TC input
Thermocouple type........................................ B, E, J, K, L, N, R, S, T, U,
W3, W5, LR
Cold junction compensation
(CJC).............................................................. Constant, internal or external
via a Pt100 or Ni100 sensor

Voltage input
Measurement range....................................... -800...+800 mV
Min. measurement range (span).................... 2.5 mV
Input resistance.............................................. 10 MΩ

Output specifications
5337A-012221

Current output
Signal range................................................... 4…20 mA
Min. signal range............................................ 16 mA
Load (@ current output)................................. ≤ (Vsupply - 8) / 0.023 [Ω]

You might also like