Starvert Ig5: Ower in Motion
Starvert Ig5: Ower in Motion
Starvert Ig5: Ower in Motion
Starvert iG5
0.37 - 4.0kW (0.5 - 5.4HP) 1 and 3 phase 200 - 230 Volts, 3 phase 380 - 460 Volts
Contents
Overview 02
Dimension 12
Standard features
kW / Voltage Ratings:
0.5 ~ 2HP, 200-230VAC, 1phase
0.5 ~ 5HP, 200-230VAC, 3phase
0.5 ~ 5HP, 380-460VAC, 3phase
Enclosure: IP00 ~ IP20
Inverter Type: PWM with IGBT
Control Method: Volts / Hertz with Space Vector Technology
Built-in RS-485
Built-in ModBus-RTU
Compact iG5, Built-in PID control
is the best for a small and cost Removable keypad (Able to read & write parameter)
150% torque at 0.5Hz
effective configuration. Trip-free operation algorithm
8 preset speeds
3 jump(skip) frequencies
3 Multifuctional inputs
1 Multifuctional output
Analog output (0~12V)
PNP and NPN dual directional signals
Speed search
3 wire operation
1 to 10 kHz carrier frequency
Built-in Braking transistor
Manual/Auto torque boost
Options
Cable for Remote Keypad Operations(2,3 and 5 meters)
DIN rail base for easy installation
Application
Converting Commercial washing machine
Fan Grinder
Pump Textile machine
Food processing machine Material handling machine
Electric shutter Centrifuge
Dryer Elevator door
Running machine Tooling machine
Overheat
02
Starvert iG5
Reduced size
Enhancing its performance the iG5 shows much smaller size
compares to the previous model, the iG series.
Maximum 50% of total volume has been reduced in iG5 in order to
mount it easily on smaller control panel and DIN rail with less weight.
It allows more cost effective panel construction and system design.
RS - 485
TM
ModBus-RTU
03
Features & Selection Guide
Trip
=Filter= =Offset= =Record Length= =Trigger= =Filter= =Offset= =Record Length= =Trigger=
Smoothing : OFF Ch1 : 0.00V Main : 10k Mode : AUTO Smoothing : OFF Ch1 : 0.00V Main : 10k Mode : AUTO
BW : FULL Ch2 : 0.00V Zoom : 500 Type : EDGE CH1 BW : FULL Ch2 : 0.00V Zoom : 500 Type : EDGE CH1
CH3 : 0.00V Delay : 0.0ns CH3 : 0.00V Delay : 0.0ns
CH4 : 0.00V Hold Off : MINIMUM CH4 : 0.00V Hold Off : MINIMUM
LG Starvert drive
04
Starvert iG5
Multi-step accel/decel time 0 ~ 6,000 sec, up to 8 types can be set and selected for each setting (use the multi- function terminal),
Accel/Decel pattern : linear pattern, U pattern, S pattern, Optimum, Minimum
Emergency stop Interrupts the output of the drive
Operation Jog Jog operation
Fault reset Resets fault when protective function is active
Output signal
Operation status Frequency level detection, Overload alarm, stalling, overvoltage, undervoltage, drive overheating, running, stop,
constant speed, speed searching
Fault output Contact output (30A,30C,30B) - AC250V 1A, DC30V 1A
Indicator Choose 1 from output frequency, output current, output voltage, DC voltage (Output pulse: 500Hz, Output voltage: 0 ~ 10V)
Operation DC braking, frequency limit, frequency jump, second function, slip compensation, reverse rotation prevention,
function auto restart, PID control
Drive trip Overvoltage, undervoltage, overcurrent, drive overheating, motor over heating, input/output phase loss,
Protective input/output mis-wiring, overload protection, communication error, loss of speed command, hardware fault.
function Inverter alarm Stall prevention, overload alarm
Momentary power loss Less than 15 msec : continuous operation, more than 15 msec : auto restart possible
Display Operation information Output frequency, output current, output voltage, frequency value setting, operating speed, DC voltage
Keypad Trip information Indicates the fault when the protection function activates, memorizes up to 5 faults
Ambient temperature -10 °C ~ 40 °C
Storage temperature -20 °C ~ 65 °C
Environment Ambient humidity 90 % RH max.(Non condensing)
Altitude . Vibration Below 1,000 m ˙ below 5.9m/sec2(=0.6g)
Application site No corrosive gas, combustible gas, oil mist, or dust
05
Specifications & Wiring
Wiring
DB Resistor*2
B1 B2
MCCB
1ø 230V
R U
or
3ø S V MOTOR
230/460V
50/60Hz T W
24 +
FM FM
Forward Run/Stop Output Frequency Meter
FX (0 ~ 12V : pulse output)
Reverse Run/Stop
RX CM
Drive gate block
BX
Fault Reset RST
Jog
JOG
Multi-function Input 1 P1 Factory Setting
Multi-function Input 2 `Speed-L`
P2
`Speed-M`
Multi-function Input 3 P3 `Speed-H`
A Fault output relay
Common Terminal Iess than AC250V, 1A
CM C
Iess than DC30V, 1A
B
Shield
Potentiometer
MO
(1kohm, 1/2W) Multi-function output
Power supply for
VR speed signal: Iess than DC24V, 50mA
MG
+12V, 100mA Factory setting:`RUN`
CM Common for
VR, V1, I
Speed signal Input*1
Note) " " display main circuit terminals, " " display control circuit terminals.
1. Analog speed command can be set by Voltage, Current and both of them.
2. DB resistor is optional.
06
Starvert iG5
Starting Contact
BX Drive gate block When the BX signal is ON, the output of the drive is cut off. When the motor uses an mechanical brake to stop,
Function Slection
BX is used to cut off the output signal. When the BX signal, which does not cut off by latching, is OFF and the
FX signal (or the RX signal) is ON, the motor keeps running, so be cautious.
RST Fault reset Used to release the protective status when the protective circuit is active.
CM Sequence common Used for the common terminal for contact input terminals.
VR Frequency setting power(+12V) Used as power for the analog frequency setting. Maximum output is +12V, 100mA.
Analog Frequency V1 Frequency reference (Voltage) Used for frequency reference and uses 0-10V for input. Input resistance is 20 k
Setting I Frequency reference(Current) Used for frequency reference and uses DC 4-20mA for input. Input resistance is 250
CM Frequency setting common terminal Common terminal for the analog frequency reference signal and the FM (for monitoring).
FM.CM Analog/digital output Outputs one of the followings: output frequency, output current, output voltage, DC link voltage.
Pulse (For external monitoring) Factory default is set to output frequency. Maximum output voltage and output current is 0-12V, 1mA.
Output signal
Keypad
Class Display Name Description
FUNC Program key Press to change the parameter setting.
UP Up key Press to move through codes or to increase the parameter values.
KEY DOWN Down key Press to move through codes or to decrease the parameter values.
RUN Run key Use to operate the drive
STOP/RESET STOP/RESET key Press to stop during operation. Press to reset when a fault has occurred.
REV Reverse run During reverse run.
FWD Forward run During forward run.
LED
SET Setting When the user is setting the parameters using the FUNC key
RUN Operating When in constant speed and blinks when accelerating or decelerating.
Input / Output Group Multifunction terminal setting and Sequence operation parameters
07
Terminal Configuration, Keypad & Parameter Navigation
Parameter navigation
RUN REV
FUNC FUNC
FUNC FUNC
08
Program parameter descriptions
1. Drive Group [DRV]
Factory Adjustable
Code Description Keypad Display Setting Range Units
Default during run
DRV-00 Output Frequency during running, Reference Frequency during stop 0.00 0 to Max. Freq. (FU1-20) 0.01 60.00 [Hz]* Yes
DRV-01 Acceleration Time ACC 0 to 6000 [sec] 0.1 10.0 [sec] Yes
DRV-02 Deceleration Time 0 to 6000 [sec] 0.1 10.0 [sec] Yes
DRV-03 Drive Mode (Run/Stop method) 0 (keypad) - 1 No
1 (Keypad-2)
2 (Fx/Rx-2)
3 (ModBus-RTU)
DRV-04 Frequency Mode (Freq. setting method) 0 [Keypad-1] - 0 No
1 (Keypad-2)
2 (V1)
3 (I)
4 (V1+I)
5 (ModBus-RTU)
DRV-05 Step Frequency 1 Starting freq (FU1-22) Yes
to Max. freq (FU1-20) 0.01 10.00 [Hz]
DRV-06 Step Frequency 2 0.01 20.00 [Hz]
DRV-07 Step Frequency 3 0.01 30.00 [Hz]
DRV-08 Output Current * [A] - - [A] -
DRV-09 Motor Speed * [rpm] - - [rpm] -
DRV-10 DC link Voltage * [V] - - [V] -
DRV-11 User Display selection , , Selected in FU2-73 - - -
(User disp)
DRV-12 Fault Display - - nOn -
DRV-13 Motor Direction set F (Forward) r (Reverse) F Yes
DRV-20 FU1 Group selection
DRV-21 FU2 Group selection
DRV-22 I/O Group selection
2. Function Group1[FU1]
FU1-00 Jump to desired code # F0 1 to 99 1 3 Yes
FU1-03 Run Prevention F3 0 (None) 0 No
1 (Forward Prev)
2 (Reverse Prev)
FU1-05 Acceleration Pattern F5 0 (Linear) 0 No
1 (S-curve)
2 (U-curve)
3 (Minimum)
4 (Optimum)
FU1-06 Deceleration Pattern F6 0 (Linear) 0 No
1 (S-curve)
2 (U-curve)
3 (Minimum)
4 (Optimum)
FU1-07 Stop Mode F7 0 (Decel) 0 No
1 (DC-brake)
2 (Free-run)
FU1-08 DC Injection Braking Frequency F8 FU1-22 to 50 [Hz] 0.01 5.00 [Hz] No
FU1-09 DC Injection Braking On-delay Time F9 0 to 60 [sec] 0.01 0.5 [sec] No
FU1-10 DC Injection Braking Voltage FI0 0 to 200 [%] 1 50 [%] No
FU1-11 Starting DC Injection Braking Time FI I 0 to 60 [sec] 0.1 1.0 [sec] No
FU1-12 Starting DC Injection Braking Voltage FI2 0 to 200 [%] 1 50 [%] No
FU1-13 Starting DC Injection Braking Time FI3 0 to 60 [sec] 0.1 0.0 [sec] No
FU1-20 Maximum Frequency F20 40 to 400 [Hz] 0.01 60.00 [Hz]* No
FU1-21 Base Frequency F2 I 30 to FU1-20 0.01 60.00 [Hz]* No
FU1-22 Starting Frequency F22 0.1 to 10 [Hz] 0.01 0.50 [Hz] No
FU1-23 Frequency Limit selection F23 0 (No) - No
1 (Yes)
FU1-24 Low Limit Frequency F24 FU1-22 to FU1-25 0.01 0.50 [Hz] No
FU1-25 High Limit Frequency F25 FU1-24 to FU1-20 0.01 60.00 [Hz]* No
FU1-26 Manual/Auto Torque Boost selection F26 0 (Manual) - 0 No
1 (Auto)
FU1-27 Torque Boost in Forward Direction F27 0 to 15 [%] 0.1 5.0 [%] No
FU1-28 Torque Boost in Reverse Direction F28 0 to 15 [%] 0.1 5.0 [%] No
FU1-29 Volts/Hz Pattern F29 0 (Linear) - 0 No
1 (Square)
2 (User V/F)
FU1-30 User V/F - Frequency 1 F30 0 to FU1-32 0.01 15.00 [Hz]* No
FU1-31 User V/F - Voltage 1 F3 I 0 to 100 [%] 1 25 [%] No
FU1-32 User V/F - Frequency 2 F32 FU1-30 to FU1-20 0.01 30.00 [Hz]* No
FU1-33 User V/F - Voltage 2 F33 0 to 100 [%] 1 50 [%] No
FU1-34 User V/F - Frequency 3 F34 FU1-32 to FU1-20 0.01 45.00 [Hz]* No
FU1-35 User V/F - Voltage 3 F35 0 to 100 [%] 1 75 [%] No
FU1-36 User V/F - Frequency 4 F36 FU1-34 to FU1-20 0.01 60.00 [Hz]* No
FU1-37 User V/F - Voltage 4 F37 0 to 100 [%] 1 100 [%] No
FU1-38 Output Voltage Adjustment F38 40 to 110 [%] 0.1 100[%] No
FU1-39 Energy Save Level F39 F39 0 to 30 [%] 1 0 [%] Yes
FU1-50 Electronic Thermal selection F50 0 (No) - 0 Yes
1 (Yes)
FU1-51 Electronic Thermal Level for 1 minute F5 I FU1-52 to 150 [%] 1 150 [%] Yes
FU1-52 Electronic Thermal Level for continuous F52 50 to FU1-51 1 150 [%] Yes
FU1-53 Electronic Thermal Characteristic selection (Motor type) F53 0 (Self-cool) - 0 Yes
1 (Forced-cool)
09
Program Parameter Descriptions
Factory Adjustable
Code Description Keypad Display Setting Range Units
Default during run
FU1-54 Overload Warning Level F54 30 to 150 [%] 1 150 [%] Yes
FU1-55 Overload Warning Hold Time F55 0 to 30 [sec] 0.1 10.0 [sec] Yes
FU1-56 Overload Trip selection F56 0 (No) - 1 Yes
1 (Yes)
FU1-57 Overload Trip level F57 30 to 200 [%] 1 180 [%] Yes
FU1-58 Overload Trip Delay Time F58 0 to 60 [sec] 1 60.0 [sec]
FU1-59 Stall Prevention Mode selection F59 000 - 111 (bit set) bit 000 No
Bit 0: during Accel.
Bit 1: during Steady speed
Bit 2: during Decel.
FU1-60 Stall Prevention Level F60 30 to 150 [%] 1 150 [%] No
FU1-99 Return Code - - -
Factory Adjustable
Code Description Keypad Display Setting Range Units
Default during run
FU2-73 User Display selection H73 0 (Voltage) - 0 Yes
1 (Watt)
2 (Torque)
FU2-74 Gain for Motor Speed Display H74 1 to 1000 [%] 1 100 [%] Yes
FU2-75 DB(Dynamic Braking)Resistor H75 0 [None] - 0 Yes
Mode selection 1 [None]
2 (Ext.DB-R)
FU2-76 Duty of Dynamic Braking Resistor H76 0 to 30 [%] 1 10 [%] Yes
FU2-79 Software Version H79 - . E -
FU2-81 2nd Acceleration Time H8 I 0 to 6000 [sec] 0.1 5.0 [sec] Yes
FU2-82 2nd Deceleration Time H82 0 to 6000 [sec] 0.1 10.0 [sec] Yes
FU2-83 2nd Base Frequency H83 30 to FU1-20 0.01 60.00 [Hz]* No
FU2-84 2nd V/F Pattern H84 0 (Linear) - 0 No
1 (Square)
2 (User V/F)
FU2-85 2nd Forward Torque Boost H85 0 to 15 [%] 0.1 5.0 [%] No
FU2-86 2nd Reverse Torque Boost H86 0 to 15 [%] 0.1 5.0 [%] No
FU2-87 2nd Stall Prevention Level H87 30 to 150 [%] 1 150 [%] No
FU2-88 2nd Electronic Thermal Level for 1 minute H88 FU2-89 to 150 [%] 1 150 [%] Yes
FU2-89 2nd Electronic Thermal Level for continuous H89 50 to FU2-88(maximum 150%) 1 100 [%] Yes
FU2-90 2nd Rated Motor Current H90 0.1 to 99.9 [A] 0.1 1.8 [A] No
FU2-91 Read Parameters into Keypad from Inverter H9 I 0 (No) - 0 No
1 (Yes)
FU2-92 Write Parameters to Inverter from Keypad H92 0 (No) - 0 No
1 (Yes)
FU2-93 Initialize Parameter H93 0 (No) - 0 No
1 (All Groups)
2 (DRV)
3 (FU1)
4 (FU2)
5 (I/O)
FU2-94 Parameter Write Protection H94 0 to 255 1 0 Yes
FU2-99 Return Code - 1 Yes
Factory Adjustable
Code Description Keypad Display Setting Range Units
Default during run
I/O-31 Acceleration Time 4 I 3I 0 to 6000 [sec] 0.1 50.0 [sec] Yes
I/O-32 Deceleration Time 4 I 32 0 to 6000 [sec] 0.1 50.0 [sec] Yes
I/O-33 Acceleration Time 5 I 33 0 to 6000 [sec] 0.1 40.0 [sec] Yes
I/O-34 Deceleration Time 5 I 34 0 to 6000 [sec] 0.1 40.0 [sec] Yes
I/O-35 Acceleration Time 6 I 35 0 to 6000 [sec] 0.1 30.0 [sec] Yes
I/O-36 Deceleration Time 6 I 36 0 to 6000 [sec] 0.1 30.0 [sec] Yes
I/O-37 Acceleration Time 7 I 37 0 to 6000 [sec] 0.1 20.0 [sec] Yes
I/O-38 Deceleration Time 7 I 38 0 to 6000 [sec] 0.1 20.0 [sec] Yes
I/O-40 FM (Frequency Meter) Output selection I 40 0 (Frequency) - 0 Yes
1 (Current)
2 (Voltage)
3 (DC link Vtg)
I/O-41 FM Output Adjustment I 4I 10 to 200 [%] 1 100 [%] Yes
I/O-42 Frequency Detection Level I 42 0 to FU1-20 0.01 30.00 [Hz] Yes
I/O-43 Frquency Detection Bandwidth I 43 0 to FU1-20 0.01 10.00 [Hz] Yes
I/O-44 Multi-function Output define (MO)15, 16, 18, 19, 20(-Reserved-) I 44 0 (FDT-1) - 12 Yes
1 (FDT-2)
2 (FDT-3)
3 (FDT-4)
4 (FDT-5)
5 (IOL)
6 (IOL)
7 (Stall)
8 (OV)
9 (LV)
10 (OH)
11 (Lost Command)
12 (Run)
13 (Stop)
14 (Steady)
17 (Search)
I/O-45 Fault Output Relay setting (30A, 30B, 30C) I 45 000 - 111 (bit set) - 010 Yes
Bit 0: LV Bit 1: All Trip
Bit 2: Auto retry
I/O-46 Inverter Number I 46 1 to 32 1 1 Yes
I/O-47 Baud Rate I47 I 47 0 (1200 bps) - 3 Yes
1 (2400 bps)
2 (4800 bps)
3 (9600 bps)
4 (19200 bps)
I/O-48 Operating selection at Loss of Freq. Reference I 48 0 (None) - 0 Yes
1 (FreeRun)
2 (Stop)
I/O-49 Waiting Time after Loss of Freq. Reference I 49 0.1 to 120 [sec] 0.1 1.0 [sec] Yes
I/O-50 Communication Protocol selection I 50 0 (LG- BUS) 7 Yes
1~6(ModbusASCII)
7~9 (Modbus-RTU)
I/O-99 Return Code - 1 Yes
Note: Parameters that are set by bit are ON (1) when the upper LED is lit. (F59, H19, H22, I15, I16, I45 are the parameters that are set by bit.)
Note: *marked default value changes depend on the main frequency setting in factory(50 / 60Hz)
Dimension : mm(inch)
4.5
iG5
VARIABLE FREQUENCY DRIVER
00.00
FRCQUENCY 0.2-400Hz
CURRENT 5A
OUTPUT CAPACITY 1.5kVA
SOURCE AC200-230V 50/60Hz
FUNC
International system Co, Ltd Made In Korea
SV015IG5-2
H2
RUN STOP
RESET
CAUTION
Read the manual and follow the safety instruction before installation or operation
Do not the power supply to the drive output terminal (U, V, W)
Before opening the cover, disconnect all power and wait at least 3 minutes untill DC
bus capacitors discharge.
`Risk of Electric Shock`-more than one disconnect switch is required to de -
energize the equipment before servicing.
4
4.5 4.5
W2
W1 Inverter HP W1 W2 H1 H2 D1
SV004iG5-1 0.5 100(3.94) 88(3.46) 128(5.04) 117.5(4.63) 130.9(5.15)
SV004iG5-2 0.5 100(3.94) 88(3.46) 128(5.04) 117.5(4.63) 130.9(5.15)
SV008iG5-1 1 130(5.12) 118(4.65) 128(5.04) 117.5(4.63) 150.9(5.94)
SV008iG5-2 1 100(3.94) 88(3.46) 128(5.04) 117.5(4.63) 130.9(5.15)
SV015iG5-1 2 150(5.90) 138(5.43) 128(5.04) 117.5(4.63) 155(6.10)
SV015iG5-2 2 130(5.12) 118(4.65) 128(5.04) 117.5(4.63) 150.9(5.94)
SV022iG5-2 3 150(5.90) 138(5.43) 128(5.04) 117.5(4.63) 155(6.10)
D1
Options
Option Description
Peripheral devices
Wire, mm2(AWG) AC
Drive Models kW MCCB, ELB Magnetic Contactor AC Reactor DC Reactor
R,S,T U,V,W Ground Input
SV004iG5-1 0.37 ABS33a, EBS33 SMC-10P 2(14) 2(14) 3.5(12) 10A 2.13mH, 5.7A 7.00mH, 5.4A
SV008iG5-1 0.75 ABS33a, EBS33 SMC-10P 2(14) 2(14) 3.5(12) 10A 2.13mH, 5.7A 7.00mH, 5.4A
SV015iG5-1 1.5 ABS33a, EBS33 SMC-10P 2(14) 2(14) 3.5(12) 10A 2.13mH, 5.7A 7.00mH, 5.4A
SV004iG5-2 0.37 ABS33a, EBS33 SMC-10P 2(14) 2(14) 3.5(12) 10A 2.13mH, 5.7A 7.00mH, 5.4A
SV008iG5-2 0.75 ABS33a, EBS33 SMC-10P 2(14) 2(14) 3.5(12) 10A 2.13mH, 5.7A 7.00mH, 5.4A
SV015iG5-2 1.5 ABS33a, EBS33 SMC-10P 2(14) 2(14) 3.5(12) 15A 1.20mH, 10A 4.05mH, 9.2A
SV022iG5-2 2.2 ABS33a, EBS33 SMC-15P 2(14) 2(14) 3.5(12) 25A 0.88mH, 14A 2.92mH, 13A
SV037iG5-2 3.7 ABS33a, EBS33 SMC-20P 3.5(12) 3.5(12) 3.5(12) 40A 0.56mH, 20A 1.98mH, 19A
SV040iG5-2 4 ABS33a, EBS33 SMC-20P 3.5(12) 3.5(12) 3.5(12) 40A 0.56mH, 20A 1.98mH, 19A
SV004iG5-4 0.37 ABS33a, EBS33 SMC-10P 2(14) 2(14) 2(14) 6A 8.63mH, 2.8A 28.62mH, 2.7A
SV008iG5-4 0.75 ABS33a, EBS33 SMC-10P 2(14) 2(14) 2(14) 6A 8.63mH, 2.8A 28.62mH, 2.7A
SV015iG5-4 1.5 ABS33a, EBS33 SMC-10P 2(14) 2(14) 2(14) 10A 4.81mH, 4.8A 16.14mH, 4.6A
SV022iG5-4 2.2 ABS33a, EBS33 SMC-20P 2(14) 2(14) 2(14) 10A 3.23mH, 7.5A 11.66mH, 7.1A
SV037iG5-4 3.7 ABS33a, EBS33 SMC-20P 2(14) 2(14) 2(14) 20A 2.34mH, 10A 7.83mH, 10A
13 SV040iG5-4 4 ABS33a, EBS33 SMC-20P 2(14) 2(14) 2(14) 20A 2.34mH, 10A 7.83mH, 10A
DB Resistor, Options & Peripheral Devices
RFI Filters
IG5 Series Footprint Filter
Drive Models Power Code Current Tension Leakage Dimensions Mounting Weight Mount Output
Voltage Current LWH YX Chokes
Drive Models Power Code Current Tension Leakage Dimensions Mounting Weight Mount Output
Voltage Current LWH YX Chokes
Y X
W
Type D W H X O
CARGA
X
RED
W
W X FS-1 21 85 46 70 5
FS-2 28.5 105 62 90 5
FS-3 48 150 110 125 x 30 5
FS-4 58 200 170 180 x 45 5
L
L
INVERTER
SHIELDED CABLE
FF Series (Footprint) MOTOR
FILTER
14
LG constantly endeavor to improve
our products so that information
in this catalog is subject to HEAD OFFICE
change without notice. LG TWIN TOWERS, 20 Yoido-dong, Youngdungpo-gu, Seoul, 150-721, Korea.
Tel.(82-2)3777- 4640 ~ 4649
Fax.(82-2)3777- 4648
http://www.lgis.com
http://www.fasolution.com
OVERSEAS BRANCHES
Beijing Tel.86-10-6462-3254, 3256, 3259, 6464-8637
Shanghai Tel.86-21-6252-3367, 3795, 6240-3477
Hanoi Tel.84-4-882-0222
Dalian Tel.86-411-730-6495, 730-7580
Tokyo Tel.81-3-3582-9126
Jakarta Tel.62-21-897-4311