Syntec control network uses SMB V1 protocol and a designated static IP. The SMB protocol must be
enabled and the IP must be configured to the connected port on the computer. Lastly the username, PC
name, and password must be entered into the control. You may make a guest account on the PC for the
control to use as access to the computer if preferred.
The following document discusses how to set the IP and enable the protocol on windows 10 if you are
not familiar in doing so. If you are familiar, you may do so and skip to section 3.
1
I . Direct Ethernet Connection to Windows 10 Computer:
Computer Setting:
1) Go to “Control Panel”
2) Under “Network and Internet”, click “View network status and tasks”
2
7) Select “Use the following IP address” and type in those numbers accordingly
IP Address: “10.10.70.21”
Subnet Mask: “255.255.255.0”
Default Gateway: You can leave this empty.
3
15) Go to “Control Panel”, then go to “Uninstall a program”
16) Click on “Turn Windows features on or off”, founded on the left-hand side
17) Scroll down and find “SMB 1.0/CIFS File Sharing Support”
18) Make sure all three boxes of the SMB 1.0 are checked same as the picture
4
6) Click on “Turn Windows features on or off”, founded on the left-hand side
7) Scroll down and find “SMB 1.0/CIFS File Sharing Support”
8) Make sure all three boxes of the SMB 1.0 are checked same as the picture
12) Scroll down and find the Wireless Lan Adapter Wireless
Network Connection
5
13) Record the IP Address, Subnet Mask, and Default Gateway for the
Controller. However, you will need to change the last digit of the IP Address
in the controller to a different number (Any number is fine). Continue to
controller settings section
4)
A) Type the following numbers accordingly IF YOU
FOLLOWED I. DIRECT CONNECTION FROM CONTROL TO
WINDOWS 10 CPU
IP Address, type in 10.10.70.42
6
Subnet Mask, type in 255.255.255.0
B) Type the recorded IP address, subnet mask, and default gateway
from II. #13 if you are connecting the control direct to a wifi router.
5) For the PC Name, you will need to find your PC Name. In this case, my PC
name is IAM-1025.
6) To obtain the PC Name, simply go to Start and type in “PC Name”
And click on “View your PC name”
You should find the name in “Device specifications” section as device
name
8) For Dir Name, create a folder named “CNC” anywhere (Desktop would be
faster)
9) Then we must share the folder by doing these following steps:
Right click on the folder and select “Properties”
Select “Sharing” on the top, next to “General”
7
Click “Share”
8
Click Share then Done
Next, click “Advanced Sharing”
Check the “Share this Folder” box
Select “Permissions”
Check the “Allow Box” for the “Full Control”
9
10) Back to the controller, Type in the password of your computer’s account.
Leave it blank if there is no password
11) Save the Setting and restart the Controller
12) When you go back to that page, it should say in the Net Status “Code: 0 No
Error/Success”
10