Product Data: 24ABB3 Comfortt13 Air Conditioner With Puronr Refrigerant 1 - 1/2 To 5 Nominal Tons
Product Data: 24ABB3 Comfortt13 Air Conditioner With Puronr Refrigerant 1 - 1/2 To 5 Nominal Tons
Product Data: 24ABB3 Comfortt13 Air Conditioner With Puronr Refrigerant 1 - 1/2 To 5 Nominal Tons
Product Data
INDUSTRY LEADING
FEATURES / BENEFITS
Efficiency
S 13 SEER/ up to 11 EER
(based on tested combinations)
S Microtube Technologyt refrigeration system
S Indoor air quality accessories available
Sound
S Sound level as low as 71 dBA
Comfort
S System supports Edger Thermidistatt or standard
thermostat controls
Reliability
S Non--ozone depleting Puronr refrigerant
S Scroll compressor
S Internal pressure relief valve
S Internal thermal overload
S Filter drier
S Balanced refrigeration system for maximum reliability
Durability
Carrier’s Air Conditioners with Puronr refrigerant provide a WeatherArmort protection package:
collection of features unmatched by any other family of S Solid, durable sheet metal construction
equipment. The 24ABB has been designed utilizing Carrier’s
non--ozone depleting Puron refrigerant. S Dense wire coil guard
S Baked--on, complete outer coverage, powder paint
NOTE: Ratings contained in this document are subject to
Applications
change at any time. Always refer to the AHRI directory
(www.ahridirectory.org) for the most up--to--date ratings S Long--line -- up to 250 feet (76.20 m) total equivalent
information. length, up to 200 feet (60.96 m) condenser above
evaporator, or up to 80 ft. (24.38 m) evaporator above
condenser (See Longline Guide for more information.)
S Low ambient (down to --20_F/--28.9_C)) with
accessory kit
MODEL NUMBER NOMENCLATURE
1 2 3 4 5 6 7 8 9 10 11 12 13
N N A A A/N N N N A/N A/N A/N N N
2 4 A B B 3 3 6 A 0 N 3 0
STANDARD FEATURES
Feature 18 24 30 36 42 48 60
Puron Refrigerant X X X X X X X
SEER 13 13 13 13 13 13 13
Scroll Compressor X X X X X X X
Field Installed Filter Drier X X X X X X X
Front Seating Service Valves X X X X X X X
Internal Pressure Relief Valve X X X X X X X
Internal Thermal Overload X X X X X X X
Long Line capability X X X X X X X
Low Ambient capability with Kit X X X X X X X
Dense Grille X X X X X X X
X = Standard
2
PHYSICAL DATA
36--- 51, 42--- 30, 48--- 51, 60--- 52,
UNIT SIZE SERIES 18--- 34 24--- 35 30--- 33 30--- 51 36--- 35 48--- 36 60--- 34
61,11 50,60 61,11 62,12
Compressor Type Scroll
REFRIGERANT Puron (R--- 410A)
Control TXV (Puron Hard Shutoff)
3.15 3.15 4.62 4.10 5.42 5.34 5.84 7.37 7.00 8.80 8.00
Charge lb (kg)
(1.4) (1.43) (2.10) (1.9) (2.46) (2.4) (2.65) (3.34) (3.2) (4.0) (3.6)
COND FAN Propeller Type, Direct Drive
Air Discharge Vertical
Air Qty (CFM) 1792 2218 2163 2218 3167 2954 3167 3365 3365 3365 3365
Motor HP 1/12 1/10 1/10 1/10 1/5 1/4 1/5 1/4 1/4 1/4 1/4
Motor RPM 1100 1100 1100 1100 1100 1100 1100 1100 1100 800 1100
COND COIL
Face Area (Sq ft) 8.40 8.40 11.49 9.80 12.93 13.13 17.25 19.40 19.40 12.93 15.09
Fins per In. 20 25 25 25 25 25 25 25 25 20 20
Rows 1 1 1 1 1 1 1 1 1 2 2
Circuits 3 3 3 3 5 3 4 5 5 5 6
VALVE CONNECT. (In. ID)
Vapor 3/4 3/4 3/4 3/4 7/8 7/8 7/8 7/8 7/8 7/8 7/8
Liquid 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8
REFRIGERANT TUBES* (In. OD)
Rated Vapor* 3/4 7/8 1--- 1/8
Max Liquid Line{ 3/8
* Units are rated with 25 ft (7.6 m) of lineset length. See Vapor Line Sizing and Cooling Capacity Loss table when using other sizes and lengths of lineset.
Note: See unit Installation Instruction for proper installation.
{ See Liquid Line Sizing For Cooling Only Systems with Puron Refrigerant tables.
3
REFRIGERANT PIPING LENGTH LIMITATIONS
Liquid Line Sizing and Maximum Total Equivalent Lengths{ for Cooling Only Systems with Puronr Refrigerant:
The maximum allowable length of a residential split system depends on the liquid line diameter and vertical separation between indoor and
outdoor units.
See Table below for liquid line sizing and maximum lengths :
4
REFRIGERANT CHARGE ADJUSTMENTS
Liquid Line Size Puron Charge oz/ft (g/m)
0.60 (17.74)
3/8
(Factory charge for lineset = 9 oz / 266.16 g)
5/16 0.40 (11.83)
1/4 0.27 (7.98)
Units are factory charged for 15 ft (4.6 m) of 3/8” liquid line. The factory charge for 3/8” lineset 9 oz. When using other length or diameter
liquid lines, charge adjustments are required per the chart above.
Charging Formula:
[(Lineset oz/ft x total length) – (factory charge for lineset)] = charge adjustment
Example 1: System has 15 ft of line set using existing 1/4“ liquid line. What charge adjustment is required?
Formula: (.27 oz/ft x 15ft) – (9 oz) = (-4.95) oz.
Net result is to remove 4.95 oz of refrigerant from the system
Example 2: System has 45 ft of existing 5/16” liquid line. What is the charge adjustment?
Formula: (.40 oz/ft. x 45ft) – (9 oz.) = 9 oz.
Net result is to add 9 oz of refrigerant to the system
NOTE: Conditions must be favorable for charging by subcooling method. Indoor temperature must be 70_F to 80_F (21.1_C to 26.7_C),
and outdoor temperature must be 70_F to 100_F (21.1_C to 37.8_C). If outside these conditions, adjust charge for long line sets by weigh--in
method.
AC with Puronr Refrigerant Long Line Description ft (m) (Beyond these lengths, long line accessories are required)
Liquid Line Size Units On Same Level Outdoor Below Indoor Outdoor Above Indoor
No accessories needed within al- No accessories needed within
1/4 + TXV 175 (53.3)
lowed lengths allowed lengths
5/16 + TXV 120 (36.6) 50 (15.2) vertical or 120 (36.6) total 120 (36.6)
3/8 + TXV 80 (24.4) 35 (10.7) vertical or 80 (24.4) total 80 (24.4)
Note: See Residential Piping and Long Line Guideline for details
5
ACCESSORIES
Size --- Voltage, Series
KIT NUMBER KIT NAME
18--- 34 24--- 35 30--- 33 30--- 51 36--- 35 36--- 51 36--- 61 36--- 11 42--- 30 42--- 50 42--- 60 48--- 36 48--- 51 48--- 61 48--- 11 60--- 34 60--- 52 60--- 62 60--- 12
HC38GE461 MOTOR,FAN X
HC40GE466 MOTOR,FAN X X
KAACH1201AAA CRANKCASE HEATER KIT X X X X X X
KAACH1401AAA CRANKCASE HEATER KIT X X X X X X
KAACH1501AAA CRANKCASE HEATER KIT X
KAACH1801AAA CRANKCASE HEATER KIT X
KAACH1901AAA CRANKCASE HEATER KIT X X X
KAACH2001AAA CRANKCASE HEATER KIT X X
KAAFT0101AAA FREEZE THERMISTOR KIT X X X X X X X X X X X X X X X X X X X
KAATD0101TDR TIME DELAY KIT X X X X X X X X X X X X X X X X X X X
KSACY0101AAA CYCLE PROTECTOR KIT X X X X X X X X X X X X X X X X X X X
KAAWS0101AAA WINTER START KIT X X X X X X X X X X X X X X X X X X X
KSALA0301410 LOW AMBIENT KIT X X X X X X X X X X X X X X X X X X X
KSALA0601AAA MOTORMASTER KIT X X X X X X X X X X X X
KSALA0701AAA MOTORMASTER KIT X X X X
KAALP0401PUR LOW PRESSURE SWITCH KIT X X X X X X X X X X X X X X X X X X X
KAALP0501PUR HIGH PRESSURE SWITCH KIT X X X X X X X X X X X X X X X X X X X
KSASF0101AAA SUPPORT FEET KIT X X X X X X X X X X X X
KSASF0201AAA SUPPORT FEET KIT X X X X X X X
KSASH2301COP SOUND BLANKET KIT X X X X X X X X X X X X
KSASH2401COP SOUND BLANKET KIT X X X X
KSASH2501COP SOUND BLANKET KIT X X X
6
KAALS0201LLS SOLENOID VALVE KIT X X X X X X X X X X X X X X X X X X X
KSAHS1501AAA COMPRESSOR START ASSIST X X X X X X X
KSATX0201PUR TXV KIT X X
KSATX0301PUR TXV KIT X X X X X X X X X
KSATX0401PUR TXV KIT X X X X
KSATX0501PUR TXV KIT X X X X
KSBTX0201PUR TXV KIT X X
KSBTX0301PUR TXV KIT X X X X X X X X X
KSBTX0401PUR TXV KIT X X X X X X X X
X = Accessory
AHRI RATINGS
For AHRI ratings certificates, please refer to the AHRI directory www.ahridirectory.org
Additional ratings and system combinations can be accessed via the Carrier database at: www.MyCarrierRatings.com
For performance data at specific application &/or design conditions with various indoor unit combinations, the equipment
performance calculator can be accessed at : http://rpmob.wrightsoft.com/
ACCESSORY THERMOSTATS
PART NUMBER DESCRIPTION
TP--- WEM01 Côr Thermostat
TP--- PRH01--- A edge Programmable Relative Humidity Thermostat
TP--- PAC01 edge Programmable Thermostat
TP--- NRH01 edge Non ---Programmable Relative Humidity Thermostat
TP--- NAC01 edge Non ---Programmable Thermostat
TC --- WHS01 Wi---Fi Thermostat
TC --- PAC01 Programmable Thermostat
TC --- NAC01 Non ---Programmable Thermostat
TCSNAC01 Non ---Programmable Standard Screen Thermostat
THERMOSTAT ACCESSORIES
PART NUMBER DESCRIPTION THERMOSTATS USED WITH
TP--- EXP edge EXP Card Programmable edge thermostats
TSTATCCSEN01--- B Outdoor Air Temperature Sensor TP---Pxx, TP---Nxx
TSTATXXCNV10 Thermostat Conversion Kit (4 to 5 wire) --- 10 pack All Carrier branded thermostats
TX--- MBP01 Medium Decorative Backplate TC ---Nxx
TX--- LBP01 Large Decorative Backplate TP---Pxx, TP---Nxx, TC ---Pxx
7
Accessory Description and Usage (Listed Alphabetically) (Continued)
6. Low--Ambient Pressure Switch Kit 10. Support Feet
A long life pressure switch which is mounted to outdoor unit Four or five stick--on plastic feet that raise the unit 4 in. (101.6
service valve. It is designed to cycle the outdoor fan motor in mm) above the mounting pad. This allows sand, dirt, and other
order to maintain head pressure within normal operating limits debris to be flushed from the unit base, minimizing corrosion.
(approximately 100 psig to 225 psig). The control will maintain Usage Guideline:
working head pressure at low--ambient temperatures down to 0_F Suggested in the following applications:
(--18_C) when properly installed.
Coastal installations.
Usage Guideline:
Windy areas or where debris is normally circulating.
A Low--Ambient Pressure Switch or MotorMasterr
Low--Ambient Controller must be used when cooling operation is Rooftop installations.
used at outdoor temperatures below 55_F (12.8_C). For improved sound ratings.
7. MotorMasterr Low--Ambient Controller 11. Thermostatic Expansion Valve (TXV)
A fan--speed control device activated by a temperature sensor, A modulating flow--control valve which meters refrigerant liquid
designed to control condenser fan motor speed in response to the flow rate into the evaporator in response to the superheat of the
saturated, condensing temperature during operation in cooling refrigerant gas leaving the evaporator.
mode only. For outdoor temperatures down to --20_F (--28.9_C), Kit includes valve, adapter tubes, and external equalizer tube.
it maintains condensing temperature at 100_F 10_F (37.8_C Hard shut off types are available.
5.5_C). NOTE: When using a hard shut off TXV with single phase
Usage Guideline: reciprocating compressors, a Compressor Start Assist Capacitor
A MotorMasterr Low Ambient Controller or and Relay is required.
Low--Ambient Pressure Switch must be used when Usage Guideline:
cooling operation is used at outdoor temperatures Required to achieve AHRI ratings in certain equipment
below 55_F (12.8_C). combinations. Refer to combination ratings.
Suggested for all commercial applications. Hard shut off TXV or LLS required in air conditioner
8. Outdoor Air Temperature Sensor long line applications.
Designed for use with Carrier Thermostats listed in this Required for use on all zoning systems.
publication. This device enables the thermostat to display the 12. Time--Delay Relay
outdoor temperature. This device also
An SPST delay relay which briefly continues operation of indoor
is required to enable special thermostat features such as auxiliary blower motor to provide additional cooling after the compressor
heat lock out. cycles off.
Usage Guideline: NOTE: Most indoor unit controls include this feature. For those
Suggested for all Carrier thermostats listed in this that do not, use the guideline below.
publication.
Usage Guideline:
9. Sound Hood
For improved efficiency ratings for certain
Wraparound sound reducing cover for the compressor. Reduces combinations of indoor and outdoor units. Refer to
the sound level of the compressor. AHRI Unitary Directory.
Usage Guideline: 13. Winter Start Control
Suggested when unit is installed closer than 15 ft (4.57 m) to This control is designed to alleviate nuisance opening of the
quiet areas, bedrooms, etc. low--pressure switch by bypassing it for the first 3 minutes of
Suggested when unit is installed between two houses less operation.
than 10 ft (3.05 m) apart.
8
ELECTRICAL DATA
UNIT SIZE --- OPER VOLTS* COMPR FAN MAX FUSE** or
VOLTAGE, V/PH MCA
MAX MIN LRA RLA FLA CKT BRK AMPS
SERIES
18--- 34 47.5 9.0 0.50 11.8 20
24--- 35 62.9 10.9 0.70 14.3 25
30--- 33 67.8 12.8 0.60 16.6 25
36--- 35 208/230/1 253 197 79.0 13.6 1.10 18.1 30
42--- 30 112.0 17.9 1.10 23.5 40
48--- 36 93.0 18.3 1.40 24.3 40
60--- 34 125.0 22.1 1.40 29.0 50
30--- 51 58.0 8.3 0.77 11.2 20
36--- 51 71.0 10.5 1.40 14.5 20
42--- 50 208/230 ---3 253 187 88.0 13.5 1.10 18.0 30
48--- 51 83.1 13.1 1.40 17.8 30
60--- 52 110.0 16.0 1.40 21.4 30
36--- 61 38.0 5.6 0.70 7.7 15
42--- 60 44.0 6.0 0.60 8.1 15
460 ---3 506 414
48--- 61 41.0 6.1 0.70 8.3 15
60--- 62 52.0 7.8 0.70 10.5 15
36--- 11 36.5 3.8 0.50 5.3 15
48--- 11 575 ---3 532 518 33.0 4.4 0.50 6.0 15
60--- 12 38.9 5.7 0.50 7.6 15
* Permissible limits of the voltage range at which the unit will operate satisfactorily.
** Time ---Delay fuse.
FLA --- Full Load Amps
LRA --- Locked Rotor Amps
MCA --- Minimum Circuit Amps
RLA --- Rated Load Amps
NOTE: Control circuit is 24 ---V on all units and requires external power source. Copper wire must be used from service disconnect to unit.
All motors/compressors contain internal overload protection.
Complies with 2007 requirements of ASHRAE Standards 90.1
9
DIMENSIONS -- ENGLISH
SHIPPING
OPERATING SHIPPING SHIPPING
ELECTRICAL A B C D E F G H I J K LENGTH / WIDTH
UNIT SERIES WEIGHT WEIGHT HEIGHT
CHARACTERISTICS (Sq.)
INCH MM INCH MM INCH MM INCH MM INCH MM INCH MM INCH MM INCH MM INCH MM INCH MM INCH MM Lbs Kgs Lbs Kgs INCH MM INCH MM
24ABB318A 4 Y N N N 23 1/8 587.3 25 5/16 642.9 3/4 19.1 4 7/16 113.0 18 1/16 459.0 7 13/16 197.9 5/16 7.9 3 76.2 16 1/2 419.1 15 381.0 12 304.8 107 48.5 130 59.0 25 1/4 641.5 29 3/4 755.8
24ABB324A 5 Y N N N 23 1/8 587.3 25 5/16 642.9 3/4 19.1 4 7/16 113.0 18 1/16 459.0 7 13/16 197.9 5/16 7.9 3 76.2 12 1/2 317.5 11 279.4 12 304.8 107 48.5 127 57.6 25 1/4 641.5 29 3/4 755.8
24ABB330A 3 Y N N N 25 3/4 654.0 28 11/16 728.7 3/4 19.1 4 7/16 113.0 21 1/4 539.9 9 1/8 231.3 5/16 7.9 3 76.2 14 1/2 368.3 15 1/2 393.7 12 1/2 317.5 126 57.2 149 67.6 27 7/8 708.2 33 3/16 843.1
24ABB330A 1 N Y N N 23 1/8 587.3 28 11/16 729.3 3/4 19.1 4 7/16 113.0 18 1/16 459.0 7 13/16 197.9 5/16 7.9 3 76.2 16 1/2 419.1 15 381.0 14 355.6 111 50.3 136 61.7 25 1/4 641.5 33 3/16 843.1
24ABB336A 5 Y N N N 31 3/16 792.5 25 5/16 642.4 7/8 22.2 6 9/16 166.1 24 11/16 626.3 9 1/8 231.3 5/16 7.9 3 76.2 15 9/16 395.3 16 1/2 419.1 10 1/4 260.4 134 60.8 151 68.5 33 5/16 846.6 29 3/4 755.8
24ABB336A 1 N Y Y Y 25 3/4 654.0 32 1/16 815.1 7/8 22.2 4 7/16 113.0 21 1/4 539.9 9 1/8 231.3 5/16 7.9 3 76.2 14 1/4 362.0 10 1/2 266.7 16 406.4 141 64.0 170 77.1 27 7/8 708.2 36 5/8 929.5
24ABB342A 0 Y Y Y N 31 3/16 792.5 32 1/16 815.1 7/8 22.2 6 9/16 166.1 24 11/16 626.3 9 1/8 231.3 5/16 7.9 3 76.2 15 3/4 400.1 16 1/4 412.8 13 3/4 349.3 190 86.2 218 98.9 33 5/16 846.6 36 5/8 929.5
24ABB348A 6 Y N N N 31 3/16 792.5 35 1/2 901.4 7/8 22.2 6 9/16 166.1 24 11/16 626.3 9 1/8 231.3 5/16 7.9 3 76.2 15 3/4 400.1 16 3/8 415.9 15 5/8 396.9 175 79.4 205 93.0 33 5/16 846.6 40 1015.8
24ABB348A 1 N Y Y Y 31 3/16 792.5 35 1/2 901.4 7/8 22.2 6 9/16 166.1 24 11/16 626.3 9 1/8 231.3 5/16 7.9 3 76.2 16 3/8 415.9 15 3/8 390.5 15 1/4 387.4 186 84.4 224 101.6 33 5/16 846.6 40 1015.8
24ABB360A 4 Y N N N 31 3/16 792.5 28 11/16 728.7 7/8 22.2 6 9/16 166.1 24 11/16 626.3 9 1/8 231.3 5/16 7.9 3 76.2 16 406.4 15 1/2 393.7 12 3/4 323.9 199 90.3 232 105.2 33 5/16 846.6 33 3/16 843.1
24ABB360A 2 N Y Y Y 31 3/16 792.5 28 11/16 728.7 7/8 22.2 6 9/16 166.1 24 11/16 626.3 9 1/8 231.3 5/16 7.9 3 76.2 16 406.4 15 1/2 393.7 12 3/4 323.9 198 89.8 230 104.3 33 5/16 846.6 33 3/16 843.1
Y=YES
N=NO
460-3-60
575-3-60
208-230-1-60
208/230-3-60
10
"X"
X" "Y"
UNIT SIZE MINIMUM GROUND
ND MOUNTING MINIMUM ROOF-TOP
ROOF-TO
T P MOUNTING
PAD APPLICATION
N DIMENSIONS PAD APPLICATION DIMENSIONS
Wall Wall
6” 24”
(152.4 mm) Service
(609.6)
Service
12” 12”
(304.8) (304.8)
11
Wall
Note: Numbers in ( ) = mm
IMPORTANT: When installing multiple units in an alcove, roof well, or partially enclosed area, ensure there is adequate ventilation to prevent re--circulation of discharge air.
DETAILED COOLING CAPACITIES#
CONDENSER ENTERING AIR TEMPERATURES ° F (° C)
EVAPORATOR AIR
75 (23.9) 85 (29.4) 95 (35) 105 (40.6) 115 (46.1)
EWB Capacity MBtuh Total Sys- Capacity MBtuh Total Sys- Capacity MBtuh Total Sys- Capacity MBtuh Total Sys- Capacity MBtuh Total Sys-
CFM
° F (° C) Total Sens‡ tem KW** Total Sens‡ tem KW** Total Sens‡ tem KW** Total Sens‡ tem KW** Total Sens‡ tem KW**
24ABB318ABN34 Outdoor Section With CNPV*2414AL* Indoor Section
72 (22.2) 21.21 11.38 1.27 20.31 11.05 1.42 19.41 10.71 1.59 18.37 10.33 1.78 17.33 9.96 2.02
67 (19.4) 19.33 14.06 1.28 18.52 13.73 1.43 17.62 13.36 1.60 16.64 12.96 1.79 15.65 12.56 2.02
525 63 (17.2)†† 18.04 16.20 1.29 17.23 15.83 1.44 16.39 15.44 1.60 15.49 15.02 1.79 14.60 14.56 2.02
62 (16.7) 17.76 16.72 1.29 16.97 16.34 1.44 16.16 15.93 1.60 15.36 15.36 1.79 14.58 14.58 2.02
57 (13.9) 17.47 17.47 1.30 16.77 16.77 1.44 16.08 16.08 1.60 15.34 15.34 1.79 14.56 14.56 2.02
72 (22.2) 21.47 11.95 1.30 20.62 11.65 1.45 19.68 11.30 1.62 18.64 10.93 1.81 17.55 10.55 2.05
67 (19.4) 19.71 15.05 1.31 18.81 14.68 1.46 17.90 14.32 1.63 16.89 13.92 1.82 15.88 13.52 2.05
600 63 (17.2)†† 18.40 17.43 1.32 17.61 17.05 1.46 16.77 16.64 1.63 15.96 15.96 1.82 15.14 15.14 2.05
62 (16.7) 18.19 18.01 1.32 17.54 17.28 1.46 16.74 16.74 1.63 15.96 15.96 1.82 15.14 15.14 2.05
57 (13.9) 18.12 18.12 1.32 17.44 17.44 1.47 16.72 16.72 1.63 15.93 15.93 1.82 15.12 15.12 2.05
72 (22.2) 21.70 12.53 1.33 20.81 12.21 1.48 19.86 11.87 1.65 18.78 11.49 1.84 17.62 11.09 2.06
67 (19.4) 19.88 15.95 1.34 19.03 15.61 1.49 18.11 15.24 1.66 17.08 14.83 1.85 16.07 14.43 2.08
675 63 (17.2)†† 18.79 18.56 1.35 18.02 18.02 1.49 17.27 17.27 1.66 16.44 16.44 1.85 15.60 15.60 2.08
62 (16.7) 18.71 18.71 1.34 18.02 18.02 1.49 17.26 17.26 1.66 16.44 16.44 1.85 15.59 15.59 2.08
57 (13.9) 18.70 18.70 1.34 18.00 18.00 1.49 17.24 17.24 1.66 16.41 16.41 1.85 15.57 15.57 2.08
12
62 (16.7) 22.70 19.89 1.55 21.81 19.46 1.78 20.88 18.99 2.06 19.95 19.95 2.37 18.98 18.98 2.75
57 (13.9) 22.29 22.29 1.55 21.58 21.58 1.78 20.79 20.79 2.06 19.92 19.92 2.37 18.96 18.96 2.75
72 (22.2) 27.39 14.17 1.57 26.35 13.79 1.81 25.20 13.38 2.09 23.87 12.92 2.41 22.42 12.43 2.78
67 (19.4) 25.08 17.82 1.58 24.11 17.43 1.82 23.00 17.00 2.09 21.79 16.53 2.41 20.47 16.03 2.78
800 63 (17.2)†† 23.39 17.14 1.58 22.43 16.72 1.82 21.39 16.28 2.09 20.26 15.81 2.41 19.02 15.30 2.79
62 (16.7) 23.24 21.32 1.58 22.43 22.43 1.82 21.59 21.59 2.09 20.66 20.66 2.41 19.62 19.62 2.79
57 (13.9) 23.16 23.16 1.58 22.40 22.40 1.82 21.56 21.56 2.09 20.63 20.63 2.41 19.60 19.60 2.79
72 (22.2) 27.66 14.81 1.61 26.59 14.43 1.85 25.41 14.02 2.13 24.05 13.56 2.45 22.57 13.06 2.82
67 (19.4) 25.36 18.88 1.61 24.37 18.49 1.85 23.24 18.05 2.13 22.00 17.57 2.45 20.65 17.05 2.82
900 63 (17.2)†† 23.67 18.11 1.62 22.70 17.70 1.85 21.63 17.25 2.13 20.47 16.77 2.45 19.21 16.24 2.83
62 (16.7) 23.89 23.89 1.62 23.10 23.10 1.85 22.21 22.21 2.13 21.22 21.22 2.45 20.13 20.13 2.83
57 (13.9) 23.86 23.86 1.62 23.07 23.07 1.85 22.18 22.18 2.13 21.20 21.20 2.45 20.11 20.11 2.83
13
1050 63 (17.2)†† 34.68 25.78 2.53 33.23 25.15 2.81 31.71 24.49 3.10 29.97 23.75 3.44 27.94 22.89 3.85
62 (16.7) 34.09 31.81 2.53 32.69 31.14 2.81 31.25 31.03 3.10 29.79 29.79 3.44 28.17 28.17 3.85
57 (13.9) 33.44 33.44 2.53 32.31 32.31 2.81 31.10 31.10 3.10 29.74 29.74 3.43 28.12 28.12 3.85
72 (22.2) 41.67 22.87 2.60 40.00 22.28 2.90 38.19 21.64 3.21 36.16 20.93 3.56 33.84 20.12 3.98
67 (19.4) 37.97 28.72 2.59 36.42 28.10 2.88 34.74 27.44 3.18 32.86 26.71 3.52 30.66 25.85 3.93
1200 63 (17.2)†† 35.32 27.56 2.59 33.82 26.92 2.87 32.24 26.25 3.17 30.45 25.49 3.50 28.36 24.62 3.92
62 (16.7) 35.04 34.70 2.59 33.72 33.72 2.87 32.44 32.44 3.16 30.99 30.99 3.50 29.26 29.26 3.92
57 (13.9) 34.87 34.87 2.59 33.67 33.67 2.87 32.39 32.39 3.16 30.95 30.95 3.50 29.22 29.22 3.92
72 (22.2) 42.14 24.02 2.67 40.41 23.42 2.97 38.56 22.78 3.28 36.48 22.06 3.63 34.10 21.25 4.05
67 (19.4) 38.45 30.58 2.65 36.85 29.95 2.94 35.14 29.28 3.24 33.22 28.53 3.58 30.99 27.65 4.00
1350 63 (17.2)†† 35.80 29.28 2.65 34.26 28.63 2.93 32.63 27.95 3.23 30.83 27.19 3.57 28.68 26.27 3.98
62 (16.7) 36.12 36.12 2.65 34.86 34.86 2.93 33.50 33.50 3.23 31.98 31.98 3.57 30.16 30.16 3.99
57 (13.9) 36.07 36.07 2.65 34.81 34.81 2.93 33.45 33.45 3.23 31.94 31.94 3.57 30.12 30.12 3.99
DETAILED COOLING CAPACITIES# CONTINUED
CONDENSER ENTERING AIR TEMPERATURES ° F (° C)
EVAPORATOR AIR
75 (23.9) 85 (29.4) 95 (35) 105 (40.6) 115 (46.1)
EWB Capacity MBtuh Total Sys- Capacity MBtuh Total Sys- Capacity MBtuh Total Sys- Capacity MBtuh Total Sys- Capacity MBtuh Total Sys-
CFM
° F (° C) Total Sens‡ tem KW** Total Sens‡ tem KW** Total Sens‡ tem KW** Total Sens‡ tem KW** Total Sens‡ tem KW**
24ABB342A0N30 Outdoor Section With 42 Indoor Section
72 (22.2) 48.49 25.49 3.39 46.39 24.69 3.73 44.18 23.85 4.11 41.83 22.97 4.52 39.28 22.03 4.98
67 (19.4) 44.47 31.36 3.33 42.52 30.54 3.67 40.46 29.67 4.05 38.28 28.77 4.47 35.93 27.82 4.92
1225 63 (17.2)†† 41.53 30.43 3.29 39.69 29.59 3.63 37.74 28.72 4.01 35.68 27.80 4.43 33.47 26.84 4.88
62 (16.7) 40.83 37.19 3.28 39.07 36.35 3.63 37.22 35.45 4.00 35.29 34.48 4.42 33.32 33.32 4.88
57 (13.9) 39.73 39.73 3.27 38.29 38.29 3.62 36.76 36.76 4.00 35.12 35.12 4.42 33.34 33.34 4.88
72 (22.2) 49.21 26.62 3.47 47.02 25.80 3.81 44.73 24.95 4.19 42.30 24.06 4.61 39.67 23.11 5.06
67 (19.4) 45.16 33.20 3.42 43.14 32.37 3.76 41.00 31.49 4.13 38.75 30.59 4.55 36.34 29.63 5.01
1400 63 (17.2)†† 42.22 32.16 3.38 40.31 31.31 3.72 38.28 30.42 4.09 36.17 29.51 4.51 33.89 28.53 4.97
62 (16.7) 41.69 39.75 3.37 39.91 38.85 3.71 38.02 38.02 4.09 36.34 36.34 4.51 34.45 34.45 4.98
57 (13.9) 41.25 41.25 3.37 39.72 39.72 3.71 38.08 38.08 4.09 36.34 36.34 4.51 34.45 34.45 4.98
72 (22.2) 49.75 27.70 3.56 47.50 26.88 3.90 45.14 26.02 4.27 42.64 25.12 4.69 39.94 24.16 5.14
67 (19.4) 45.69 34.99 3.50 43.61 34.15 3.84 41.42 33.28 4.22 39.12 32.36 4.63 36.65 31.38 5.09
1575 63 (17.2)†† 42.75 33.85 3.46 40.79 33.00 3.80 38.72 32.11 4.17 36.55 31.18 4.59 34.23 30.18 5.05
62 (16.7) 42.52 42.08 3.46 40.87 40.87 3.80 39.14 39.14 4.18 37.31 37.31 4.61 35.32 35.32 5.07
57 (13.9) 42.49 42.49 3.46 40.87 40.87 3.80 39.15 39.15 4.18 37.32 37.32 4.61 35.32 35.32 5.07
14
67 (19.4) 49.06 33.61 3.16 46.83 32.31 3.56 44.50 31.00 4.05 42.04 29.66 4.59 39.41 28.30 5.19
1275 63 (17.2)†† 45.60 32.39 3.14 43.53 31.11 3.55 41.33 29.80 4.03 39.02 28.47 4.57 36.55 27.11 5.18
62 (16.7) 44.79 39.62 3.14 42.76 38.21 3.55 40.64 36.76 4.02 38.42 35.26 4.57 36.16 36.16 5.17
57 (13.9) 43.29 43.29 3.13 41.65 41.65 3.54 39.91 39.91 4.02 38.08 38.08 4.56 36.11 36.11 5.17
72 (22.2) 54.71 28.64 3.23 52.22 27.41 3.65 49.58 26.17 4.13 46.83 24.91 4.67 43.91 23.63 5.28
67 (19.4) 49.84 35.47 3.22 47.54 34.13 3.63 45.12 32.78 4.11 42.58 31.40 4.65 39.90 29.99 5.26
1425 63 (17.2)†† 46.35 34.12 3.21 44.20 32.79 3.61 41.94 31.45 4.09 39.55 30.08 4.64 37.02 28.68 5.24
62 (16.7) 45.62 42.07 3.20 43.55 40.56 3.61 41.43 41.12 4.09 39.37 39.37 4.63 37.29 37.29 5.24
57 (13.9) 44.80 44.80 3.20 43.09 43.09 3.61 41.25 41.25 4.09 39.31 39.31 4.63 37.24 37.24 5.24
72 (22.2) 55.37 29.76 3.29 52.79 28.51 3.71 50.09 27.24 4.19 47.26 25.96 4.74 44.27 24.65 5.34
67 (19.4) 50.46 37.27 3.28 48.09 35.89 3.69 45.61 34.49 4.17 43.01 33.08 4.71 40.26 31.63 5.32
1575 63 (17.2)†† 46.96 35.79 3.27 44.74 34.42 3.67 42.42 33.04 4.15 39.97 31.63 4.70 37.38 30.19 5.30
62 (16.7) 46.40 44.30 3.26 44.37 44.37 3.67 42.45 42.45 4.15 40.42 40.42 4.70 38.25 38.25 5.31
57 (13.9) 46.10 46.10 3.26 44.30 44.30 3.67 42.39 42.39 4.15 40.36 40.36 4.70 38.20 38.20 5.31
NOTES:
* Tested combination.
{ Total and sensible capacities are net capacities. Blower motor heat has been subtracted.
} Sensible capacities shown are based on 80_F (27_C) entering air at the indoor coil. For sensible capacities at other than 80_F (27_C), deduct 835 Btuh
(245 kW) per 1000 CFM (480 L/S) of indoor coil air for each degree below 80_F (27_C), or add 835 Btuh (245 kW) per 1000 CFM (480 L/S) of indoor coil air per degree above 80_F (27_C).
# Detailed cooling capacities are based on indoor and outdoor unit at the same elevation per AHRI standard 210/240 ---2008. If additional tubing length and/or indoor unit is located above outdoor unit, a slight variation in capacity
may occur.
15
** System kw is total of indoor and outdoor unit kilowatts.
{{ At TVA rating indoor condition (75_F edb/63_F ewb). All other indoor air temperatures are at 80_F edb.
NOTE: When the required data falls between the published data, interpolation may be performed. Extrapolation is not an acceptable practice.
EWB — Entering Wet Bulb
NOTE: When the required data fall between the published data, interpolation may be performed. Extrapolation is not an acceptable practice.
CONDENSER ONLY RATINGS*
SST CONDENSER ENTERING AIR TEMPERATURES ° F (° C)
° F (° C) 55 (12.78) 65 (18.33) 75 (23.89) 85 (29.44) 95 (35.0) 105 (40.56) 115 (46.11)
24ABB318ABN34
TCG 16.90 15.70 14.60 13.60 12.60 10.50 9.30
30
( --- 1.11) SDT 71.20 79.70 88.40 97.90 107.30 126.60 137.10
KW 0.88 0.99 1.10 1.24 1.39 1.78 2.04
TCG 18.60 17.40 16.20 15.10 14.00 11.80 10.50
35
(1.67) SDT 71.50 80.80 89.50 98.90 108.20 127.40 138.00
KW 0.86 0.98 1.10 1.24 1.40 1.78 2.06
TCG 20.40 19.10 17.90 16.70 15.60 13.20 11.80
40
(4.44) SDT 73.50 81.90 90.60 99.90 109.20 128.70 137.60
KW 0.87 0.98 1.10 1.24 1.40 1.80 2.03
TCG 22.20 20.90 19.60 18.40 17.20 14.60 13.20
45
(7.22) SDT 73.40 83.10 91.70 101.00 110.30 129.40 138.50
KW 0.84 0.97 1.09 1.24 1.40 1.80 2.04
TCG 24.10 22.70 21.40 20.20 18.90 16.20 14.60
50
(10.0) SDT 74.30 83.50 92.80 102.10 111.40 130.40 139.50
KW 0.83 0.95 1.09 1.24 1.40 1.81 2.04
TCG 26.10 24.70 23.40 22.00 20.60 17.80 16.10
55
(12.78) SDT 75.50 84.80 94.00 103.30 112.50 131.50 140.30
KW 0.81 0.94 1.08 1.23 1.40 1.81 2.04
24ABB324ABN35
TCG 18.60 18.00 17.40 16.60 15.80 14.90 13.80
30
( --- 1.11) SDT 78.20 87.90 97.80 107.70 117.70 127.80 138.10
KW 1.03 1.19 1.39 1.61 1.88 2.19 2.57
TCG 20.60 20.00 19.30 18.50 17.60 16.60 15.40
35
(1.67) SDT 79.80 89.50 99.30 109.10 119.10 129.20 139.30
KW 1.04 1.20 1.39 1.62 1.89 2.21 2.59
TCG 22.70 22.10 21.30 20.50 19.50 18.40 17.20
40
(4.44) SDT 81.40 91.10 100.80 110.60 120.50 130.50 140.40
KW 1.04 1.21 1.40 1.64 1.91 2.23 2.60
TCG 25.00 24.30 23.50 22.60 21.60 20.40 19.10
45
(7.22) SDT 83.10 92.80 102.40 112.10 121.90 131.80 141.60
KW 1.04 1.21 1.41 1.65 1.92 2.24 2.62
TCG 27.50 26.70 25.80 24.90 23.80 22.50 21.10
50
(10.0) SDT 84.90 94.50 104.00 113.60 123.30 133.10 142.70
KW 1.05 1.22 1.42 1.66 1.93 2.26 2.63
TCG 30.10 29.30 28.30 27.30 26.10 24.80 23.30
55
(12.78) SDT 86.70 96.20 105.70 115.20 124.80 134.40 143.90
KW 1.05 1.22 1.43 1.66 1.94 2.27 2.64
24ABB330ABN33
TCG 26.40 24.90 23.20 21.70 20.20 18.70 17.10
30
( --- 1.11) SDT 71.50 80.00 88.80 98.10 107.40 116.70 126.00
KW 1.43 1.58 1.75 1.95 2.18 2.44 2.74
TCG 28.80 27.50 25.50 23.90 22.20 20.60 19.20
35
(1.67) SDT 71.70 81.30 89.90 99.20 108.40 117.70 127.20
KW 1.41 1.58 1.75 1.96 2.19 2.45 2.76
TCG 31.90 29.60 27.90 26.20 24.40 22.60 20.70
40
(4.44) SDT 73.40 82.00 91.20 100.30 109.50 118.70 127.90
KW 1.42 1.57 1.76 1.96 2.20 2.46 2.77
TCG 34.60 32.60 30.50 28.60 26.60 24.60 23.30
45
(7.22) SDT 74.50 83.50 92.50 101.60 110.70 119.70 129.40
KW 1.42 1.58 1.76 1.97 2.20 2.47 2.80
TCG 37.40 35.60 33.40 31.10 29.00 26.70 25.40
50
(10.0) SDT 75.80 85.00 94.00 102.90 111.90 120.90 130.50
KW 1.41 1.59 1.77 1.97 2.21 2.48 2.81
TCG 40.80 38.60 36.10 33.80 31.50 29.10 28.00
55
SDT 77.50 86.50 95.30 104.30 113.20 122.10 132.00
(12.78)
KW 1.41 1.59 1.77 1.98 2.22 2.49 2.83
See notes on page 18
16
CONDENSER ONLY RATINGS* CONTINUED
SST CONDENSER ENTERING AIR TEMPERATURES ° F (° C)
° F (° C) 55 (12.78) 65 (18.33) 75 (23.89) 85 (29.44) 95 (35.0) 105 (40.56) 115 (46.11)
24ABB336ABN35
TCG 30.70 28.50 26.70 25.10 23.50 21.90 20.00
30
( --- 1.11) SDT 70.70 80.00 89.40 98.80 108.20 117.60 127.00
KW 1.61 1.94 2.21 2.47 2.73 3.03 3.41
TCG 33.70 31.40 29.50 27.80 26.10 24.30 22.20
35
(1.67) SDT 71.80 81.10 90.40 99.80 109.20 118.50 127.80
KW 1.58 1.91 2.19 2.45 2.72 3.03 3.41
TCG 36.90 34.60 32.50 30.70 28.80 26.80 24.60
40
(4.44) SDT 72.90 82.20 91.50 100.90 110.20 119.40 128.60
KW 1.55 1.89 2.17 2.44 2.71 3.02 3.41
TCG 40.40 37.90 35.80 33.80 31.70 29.50 27.10
45
(7.22) SDT 74.20 83.40 92.70 102.00 111.20 120.40 129.50
KW 1.53 1.87 2.16 2.43 2.71 3.03 3.41
TCG 44.20 41.60 39.30 37.10 34.80 32.40 29.80
50
(10.0) SDT 75.50 84.70 94.00 103.20 112.30 121.40 130.50
KW 1.52 1.86 2.16 2.44 2.72 3.04 3.43
TCG 48.20 45.50 43.00 40.60 38.10 35.50 32.60
55
(12.78) SDT 77.00 86.10 95.30 104.40 113.50 122.50 131.50
KW 1.52 1.87 2.17 2.45 2.74 3.07 3.46
24ABB342A0N30
TCG 38.00 36.00 33.90 31.90 29.70 27.60 25.30
30
( --- 1.11) SDT 73.20 82.30 91.40 100.60 109.80 119.10 128.40
KW 1.95 2.20 2.48 2.80 3.14 3.53 3.95
TCG 41.90 39.70 37.40 35.10 32.80 30.50 28.00
35
(1.67) SDT 74.80 83.70 92.80 101.90 111.00 120.20 129.40
KW 1.97 2.22 2.50 2.81 3.16 3.54 3.97
TCG 46.00 43.60 41.10 38.70 36.20 33.60 30.90
40
(4.44) SDT 76.40 85.20 94.20 103.20 112.20 121.30 130.40
KW 1.98 2.23 2.52 2.83 3.18 3.56 3.98
TCG 50.30 47.70 45.10 42.40 39.60 36.80 33.90
45
(7.22) SDT 78.10 86.90 95.70 104.60 113.50 122.50 131.40
KW 2.01 2.26 2.54 2.85 3.19 3.58 4.00
TCG 54.90 52.10 49.20 46.20 43.20 40.20 37.00
50
(10.0) SDT 80.00 88.60 97.20 106.00 114.80 123.70 132.50
KW 2.03 2.28 2.56 2.87 3.21 3.60 4.01
TCG 59.70 56.60 53.40 50.20 46.90 43.50 40.10
55
(12.78) SDT 81.90 90.30 98.90 107.50 116.20 124.90 133.60
KW 2.06 2.30 2.58 2.89 3.23 3.62 4.03
24ABB348ABN36
TCG 39.10 37.90 36.60 35.10 33.40 31.50 29.40
30
( --- 1.11) SDT 72.80 82.00 91.40 100.60 110.00 119.20 128.40
KW 2.02 2.26 2.58 2.98 3.45 3.99 4.60
TCG 43.00 41.70 40.20 38.60 36.80 34.80 32.60
35
(1.67) SDT 74.20 83.40 92.60 101.90 111.10 120.30 129.40
KW 2.04 2.29 2.61 3.01 3.49 4.03 4.64
TCG 47.20 45.80 44.20 42.40 40.50 38.30 35.90
40
(4.44) SDT 75.80 84.90 94.00 103.20 112.40 121.50 130.50
KW 2.06 2.31 2.64 3.05 3.53 4.08 4.69
TCG 51.80 50.20 48.40 46.50 44.40 42.10 39.50
45
(7.22) SDT 77.40 86.50 95.50 104.60 113.70 122.70 131.70
KW 2.08 2.34 2.67 3.08 3.57 4.12 4.73
TCG 56.70 54.90 53.00 50.90 48.60 46.10 43.30
50
(10.0) SDT 79.20 88.10 97.10 106.10 115.10 124.00 132.90
KW 2.10 2.36 2.70 3.12 3.60 4.16 4.77
TCG 62.00 60.00 57.90 55.60 53.10 50.30 47.20
55
SDT 81.10 89.90 98.80 107.70 116.60 125.40 134.20
(12.78)
KW 2.11 2.38 2.73 3.14 3.63 4.19 4.81
See notes on page 18
17
CONDENSER ONLY RATINGS* CONTINUED
SST CONDENSER ENTERING AIR TEMPERATURES ° F (° C)
° F (° C) 55 (12.78) 65 (18.33) 75 (23.89) 85 (29.44) 95 (35.0) 105 (40.56) 115 (46.11)
24ABB360A0N34
TCG 53.70 51.10 48.30 45.40 42.30 39.20 36.10
30
( --- 1.11) SDT 75.80 84.90 94.10 103.10 112.20 121.30 130.40
KW 2.65 3.00 3.38 3.78 4.24 4.77 5.38
TCG 58.90 56.10 53.00 49.80 46.50 43.20 39.70
35
(1.67) SDT 77.50 86.60 95.70 104.70 113.60 122.60 131.60
KW 2.72 3.06 3.43 3.84 4.29 4.82 5.44
TCG 64.60 61.40 58.00 54.50 50.90 47.20 43.40
40
(4.44) SDT 79.40 88.40 97.30 106.20 115.10 124.00 132.90
KW 2.79 3.13 3.50 3.90 4.35 4.88 5.50
TCG 70.60 67.00 63.30 59.40 55.50 51.40 47.30
45
(7.22) SDT 81.40 90.30 99.10 107.90 116.70 125.40 134.20
KW 2.87 3.20 3.56 3.97 4.42 4.95 5.56
TCG 76.90 73.00 68.80 64.60 60.20 55.70 51.20
50
(10.0) SDT 83.50 92.20 100.90 109.60 118.30 126.90 135.60
KW 2.95 3.29 3.64 4.04 4.50 5.03 5.64
TCG 83.60 79.20 74.60 69.90 65.10 60.20 55.20
55
SDT 85.80 94.30 102.90 111.40 119.90 128.50 137.00
(12.78)
KW 3.05 3.38 3.73 4.13 4.59 5.12 5.73
* AHRI listing applies only to systems shown in Combination Ratings table.
KW --- Outdoor Unit Kilowatts Only.
SDT --- Saturated Temperature Leaving Compressor (° F/° C)
SST --- Saturated Temperature Entering Compressor (° F/° C)
TCG --- Gross Cooling Capacity (1000 Btuh)
18
GUIDE SPECIFICATIONS AIR--COOLED, SPLIT--SYSTEM AIR CONDITIONER
24ABB3
GENERAL 1--1/2 TO 5 NOMINAL TONS
System Description Condenser Coil
Outdoor--mounted, air--cooled, split--system air conditioner unit — Condenser coil will be air cooled.
suitable for ground or rooftop installation. Unit consists of a — Coil will be constructed of aluminum fins mechanically
hermetic compressor, an air--cooled coil, propeller--type bonded to copper tubes which are then cleaned,
condenser fan, and a control box. Unit will discharge supply air dehydrated, and sealed.
upward as shown on contract drawings. Unit will be used in a Refrigeration Components
refrigeration circuit to match up to a packaged fan coil or coil
unit. — Refrigeration circuit components will include
liquid--line shutoff valve with sweat connections,
Quality Assurance vapor--line shutoff valve with sweat connections,
— Unit will be rated in accordance with the latest edition system charge of Puronr (R--410A) refrigerant, and
of AHRI Standard 210. compressor oil.
— Unit will be certified for capacity and efficiency, and — Unit will be equipped with filter drier for Puron
listed in the latest AHRI directory. refrigerant.
— Unit construction will comply with latest edition of Operating Characteristics
ANSI/ ASHRAE and with NEC. — The capacity of the unit will meet or exceed _____
— Unit will be constructed in accordance with UL Btuh at a suction temperature of _____ _F/_C. The
standards and will carry the UL label of approval. Unit power consumption at full load will not exceed _____
will have c--UL--us approval. kW.
— Unit cabinet will be capable of withstanding Federal — Combination of the unit and the evaporator or fan coil
Test Method Standard No. 141 (Method 6061) 500--hr unit will have a total net cooling capacity of _____
salt spray test. Btuh or greater at conditions of _____ CFM entering
— Air--cooled condenser coils will be leak tested at 150 air temperature at the evaporator at _____ _F/_C wet
psig and pressure tested at 450 psig. bulb and _____ _F/_C dry bulb, and air entering the
— Unit constructed in ISO9001 approved facility. unit at _____ _F/_C.
Delivery, Storage, and Handling — The system will have a SEER of _____ Btuh/watt or
greater at DOE conditions.
— Unit will be shipped as single package only and is
stored and handled per unit manufacturer’s Electrical Requirements
recommendations. — Nominal unit electrical characteristics will be _____ v,
Warranty (for inclusion by specifying engineer) single phase, 60 hz. The unit will be capable of
satisfactory operation within voltage limits of _____ v
— U.S. and Canada only.
to _____ v.
PRODUCTS — Nominal unit electrical characteristics will be _____ v,
Equipment three phase, 60 hz. The unit will be capable of
Factory assembled, single piece, air--cooled air conditioner unit. satisfactory operation within voltage limits of _____ v
Contained within the unit enclosure is all factory wiring, piping, to _____ v.
controls, compressor, refrigerant charge Puronr (R--410A), and — Unit electrical power will be single point connection.
special features required prior to field start--up. — Control circuit will be 24v.
Unit Cabinet Special Features
— Unit cabinet will be constructed of galvanized steel, — Refer to section of this literature identifying accessories
bonderized, and coated with a powder coat paint. and descriptions for specific features and available
— All models have dense grille. enhancements.
Fans
— Condenser fan will be direct--drive propeller type,
discharging air upward.
— Condenser fan motors will be totally enclosed, 1--phase
type with class B insulation and permanently lubricated
bearings. Shafts will be corrosion resistant.
— Fan blades will be statically and dynamically balanced.
— Condenser fan openings will be equipped with coated
steel wire safety guards.
Compressor
— Compressor will be hermetically sealed.
— Compressor will be mounted on rubber vibration
isolators.
19
SYSTEM DESIGN SUMMARY
1. Intended for outdoor installation with free air inlet and outlet. Outdoor fan external static pressure available is less than 0.01--in. wc.
2. Minimum outdoor operating air temperature without low--ambient operation accessory is 55_F (12.8_C).
3. Maximum outdoor operating air temperature is 115_F (46.1_C).
4. For reliable operation, unit should be level in all horizontal planes.
5. For interconnecting refrigerant tube lengths greater than 80 ft (23.4 m) and/or 35 ft (10.7 m) vertical differential, consult Residential
Piping and Longline Guideline and Service Manual available from equipment distributor.
6. If any refrigerant tubing is buried, provide a 6 in. (152.4 mm) vertical rise to the valve connections at the unit. Refrigerant tubing
lengths up to 36 in. (914.4 mm) may be buried without further consideration. Do not bury refrigerant lines longer than 36 in. (914.4
mm).
7. Use only copper wire for electric connection at unit. Aluminum and clad aluminum are not acceptable for the type of connector
provided.
8. Do not apply capillary tube indoor coils to these units.
9. Factory--supplied filter drier must be installed.
Copyright 2016 Carrier Corp. S 7310 W. Morris St. S Indianapolis, IN 46231 Edition Date: 12/16 Catalog No: 24ABB3---15PD
Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. Replaces: 24ABB3--- 14PD
20