Stryker Endoscopy warrants the X-7000 Light Source shall Stryker Endoscopy be liable for any breach of war-
against defects in both materials and workmanship to the ranty in any amount exceeding the purchase price of the
registered owner at the time of purchase. All components product.
are covered by the warranty for a period of one year from
the date of purchase. No agent, employee or representative of Stryker Endoscopy
has the authority to bind the Company to any other war-
This warranty does not apply to any unit which has been ranty, affirmation, or representation concerning this
the subject of misuse, abuse, neglect, improper installation instrument.
or operation or that which has been altered, adjusted, or
tampered with by any person other than Stryker Endos- This warranty is valid only to the original purchaser of
copy authorized service personnel. Stryker Endoscopy products directly from Stryker Endos-
copy or from a Stryker Endoscopy authorized agent. The
The customer is responsible for returning the defective warranty cannot be transferred or assigned by the original
equipment to the factory at his or her own expense. purchaser.
Stryker Endoscopy or its representative will service the
unit, repair or replace any defective parts thereof, and The X-7000 Light Source warranty is void if any WARN-
return the unit. INGS, CAUTIONS, or NOTES are disregarded.
If, upon examination, it is determined that the fault has All Stryker products are warranted against defects in mate-
been caused by misuse or abnormal conditions of opera- rials and workmanship.
tion, the repairs will be billed to the customer in the same
manner as out-of-warranty repairs.
Products repaired by Stryker Endoscopy will be issued a 30 © Stryker and Stryker Endoscopy are registered trade-
day repair warranty against defects in both materials and marks of Stryker Corporation.
workmanship, provided the original warranty period has
expired. This warranty applies only to products that have
been repaired by Stryker. Instruments submitted due to
defects in materials and workmanship during the warranty
period will be repaired at no charge to the customer.
1.0 INTRODUCTION
1.1 Scope.........................................................................................................................................................................................1
1.2 Responsibility...........................................................................................................................................................................1
1.3 Upgrades...................................................................................................................................................................................1
1.4 Equipment Overview...............................................................................................................................................................1
1.5 Service Options........................................................................................................................................................................1
1.6 Maintenance Precautions........................................................................................................................................................1
1.7 Factory Service Instructions...................................................................................................................................................2
1.8 Required Equipment...............................................................................................................................................................2
1.9 Required Skills.........................................................................................................................................................................2
1.10 Required Replacement Components..................................................................................................................................2
7.0 APPENDIX
7.1 Assembly Diagram................................................................................................................................................................23
7.2 Parts Listing............................................................................................................................................................................23
7.3 Reference Documents...........................................................................................................................................................23
8.0 WARRANTY
..................................................................................................................................................................................................................24
9.0 SERVICE
..................................................................................................................................................................................................................24
1
Downloaded from www.Manualslib.com manuals search engine
1.7 FACTORY SERVICE INSTRUCTIONS 1.9 REQUIRED SKILLS
If service is needed either during or after the warranty Each diagnostic and repair procedure described in this
manual requires a technician qualified by training or expe-
period:
rience in the following areas:
Package the X-7000 carefully in the original shipping con- If a repair procedure necessitates replacements parts,
tainer, if possible. please refer to the Appendix (page 22).
2
Downloaded from www.Manualslib.com manuals search engine
2.0 Diagnostic and Corrective Maintenance
3
Downloaded from www.Manualslib.com manuals search engine
3.0 Repair Checklist and Matrix
4
Downloaded from www.Manualslib.com manuals search engine
5900 Optical Court
San Jose, CA 95138
t: 408 754 2000 f: 408 754 2505
www.stryker.com
Endoscopy
Other Observations:
Staff Recommendation:
REPAIR CODES
NMO
NSW
NDB
NJW
CHR
NCB
NSH
NHL
RCR
NFU
NFG
NPB
BUR
BAR
DFR
NC1
NLB
NSP
NFP
BBR
EBF
IRR
Replace Integrating Rod
Replace Motor
Replace Cover
Replace Fuse
Replace Feet
Error Code Failures
E1F E-1 2 3 1
E2F E-2 3 1 4 2
E3F E-3 2 1
E5F E-5 4 3 2 1
E6F E-6 1 2
Power Failures
PSF Power Switch Failure 4 3 2 1
LPF No Power 2 3 4 1
FBF Flashing Power Button 2 1 3
BUF "Bulb" in Bulb Hours 1 2 3
PFF Power only to Front Panel 1 2 3 4
Light Output Failure
NLF No Light Output 3 4 1 5 6 2
SBY Unit won't exit Standby Mode 4 2 3 6 7 1 5 8
LLF Low Light Output 5 1 4 3 2
BHF Bulb Hours not Displayed 3 1 2 4
DCF Delayed Ignition, Clicking 2 3 1
DPF Delayed Ignition, Popping 1 3 2
STR Strobing Light 3 2 1 5 4 6
LOF Light Stays On 2 3 1
Input/Output Ports
PSF Permanent Sidne Failure 1 2
FAILURE CODES
Bulb, Bulb
The following instructions apply to the removal of compo- Bulb Fan Board
nents from the X-7000. To remove a component for
replacement or repair will require the removal of certain Shutter Hot Motor Motor
Mirror Mount
other components. Components must be removed in the
Assembly
order listed in the following procedures.
Integrat-
ing Rod
The table in section 4.1.1 shows the order in which compo-
nents must be removed according to the basic physical
assembly of the X-7000. To remove a component for Slide Front Power
replacement, or repair, begin with section 4.2 and proceed Button, Panel Switch
accordingly to the appropriate section. Jaw Knob
Display
Board
Jaw
Assembly
7
Downloaded from www.Manualslib.com manuals search engine
4.1.2 Individual Replacement Instructions 4.2 CONSOLE COVER REMOVAL
8
Downloaded from www.Manualslib.com manuals search engine
4.3 POWER SOURCE COMPONENTS
Tools Required:
Basic Tool Kit
9
Downloaded from www.Manualslib.com manuals search engine
4.3.2 Lamp Ballast Replacement
Tools Required:
Basic Tool Kit
10
Downloaded from www.Manualslib.com manuals search engine
4.3.3 AC Inlet Board Replacement
Tools Required:
Basic Tool Kit
11
Downloaded from www.Manualslib.com manuals search engine
4.3.4 Ballast Fan Replacement 4.4 LIGHT SOURCE COMPONENTS
• Remove the fan wire harness assembly. • Remove the bulb module.
• Note the fan orientation. • Detach the wire harness from the control board.
• Remove the 2 nuts attaching the fan to the Chassis and • Remove the 2 nuts attaching the bulb fan housing assem-
remove the sub-assembly. bly to the chassis.
• Remove the 4 screws from the fan mounts. • Note the fan orientation.
• Remove the malfunctioning fan(s) and replace. Ensure • Remove the 4 nuts attaching the bulb fan to the fan
the correct orientation. mounts/fan ducts.
• Reinstall the 2 fan mounts with the 4 screws. • Reinstall the new fan onto the mounts/duct with 4 bolts,
ensuring the correct orientation.
• Reinstall the 2 nuts.
• Reinstall the fan assembly onto the chassis with 2 nuts.
• Reinstall the black ribbon cable, fan wire harness assem-
bly, and console cover. • Reconnect the wire harness.
• Perform Electrical Current Leakage Test (procedure 6.3). • Replace the bulb module and cover.
12
Downloaded from www.Manualslib.com manuals search engine
4.4.2 Bulb Board Replacement
13
Downloaded from www.Manualslib.com manuals search engine
4.4.5 Motor Mount Replacement
14
Downloaded from www.Manualslib.com manuals search engine
4.4.6.1 Motor Replacement
15
Downloaded from www.Manualslib.com manuals search engine
4.5 FRONT PANEL COMPONENTS 4.5.2 Potentiometer Knob Replacement
• Remove the jaw handle from the actuator shaft. • Remove the set screw from the bottom of the potentiom-
eter knob.
• Ensure that the jaw handle key (P/N 105-186-472) stays
in place on the actuator shaft. • Remove the knob from the slide pot of the front panel.
• Replace the jaw handle onto the actuator shaft. • Loosely screw the set screw into the bottom of the poten-
tiometer knob.
• Secure the jaw handle in place using the set screw.
• With the screw hole facing down, insert the potentiome-
• Reinsert the set screw and reinstall the cover. ter knob onto the slide pot.
16
Downloaded from www.Manualslib.com manuals search engine
4.5.3 Front Panel Replacement • Replace all removed components.
• Remove power cord and console cover (procedure 4.2). 4.5.4 Jaw Assembly Replacement
• Remove the jaw knob and potentiometer knob (proce- • Remove power cord and console cover (procedure 4.2).
dures 4.5.1 and 4.5.2,).
• Remove the front panel (procedure 4.5.3).
CAUTION: DO NOT DAMAGE THE JAW INTERLOCK
CABLE WHEN REMOVING THE FRONT • Remove the motor mount (procedure 4.4.5).
PANEL.
• Remove the ESST wire harness from the display board.
• Disconnect the ribbon cable from the inside of the front • Remove the 4 Phillips screws.
panel.
• Remove the jaw assembly and replace.
• Disengage the six tabs which hold the front panel onto
the chassis. • Reinsert the 4 Phillips screws.
• Remove the jaw interlock cable from the display board. • Replace the ESST wire harness, motor mount, front
panel, and cover.
• Remove the display board (procedure 4.5.6).
17
Downloaded from www.Manualslib.com manuals search engine
4.5.5 Power Switch Replacement 4.5.6 Display Board Replacement
• Remove power cord and console cover (procedure 4.2). • Remove power cord and console cover (procedure 4.2).
• Remove the jaw knob and potentiometer • Remove the front panel (procedure 4.5.3).
knob (procedures 4.5.1 and 4.5.2).
• Detach the flex cable from the display board (J1).
• Remove the front panel (procedure 4.5.3).
• Unclip the 6 front panel clips from the chassis.
• Cut the zip tie over the cables.
• Remove the ESST ring cable from the display board.
• Disconnect wire harness from display board.
• Remove the ribbon cable from the display board.
• Push in the two snap clips and push out the switch from
inside the console. • Remove the power switch wire harness from the display
board.
• Remove the LED and verify its operation.
• Remove the display board from the front panel clips.
• Replace the LED if necessary, inserting it to full depth
with the appropriate Allen wrench. • Replace the display board.
• Insert a new power switch. • Push the board onto the front panel clips.
• Reconnect the wire harness. • Reattach the power switch wire harness.
• Replace the zip tie, front panel, and console cover. • Reattach the ESST ring wire harness.
• Perform Electrical Current Leakage Test (procedure 6.3). • Reattach the front panel ribbon cable.
18
Downloaded from www.Manualslib.com manuals search engine
4.6 FUSE REPLACEMENT
Tools Required:
Basic Tool Kit
• Locate the fuse holder below the power cord inlet (see
Figure 1).
19
Downloaded from www.Manualslib.com manuals search engine
5.0 Electrical Procedures
20
Downloaded from www.Manualslib.com manuals search engine
6.0 Final Assembly and Testing
6.1 REQUIRED SKILLS • Disconnect the X-7000 power cord from the power
source.
• Basic electronics techniques
• Disconnect the video cables from the console.
• Experience in the operation of a Current Leakage Tester.
Required Equipment:
• Disconnect the safety analyzer from the X-7000.
Bio-Tek Current Leakage Tester
21
Downloaded from www.Manualslib.com manuals search engine
6.4 HI-POT TEST
22
Downloaded from www.Manualslib.com manuals search engine
7.0 Appendix
• MAP 0337
23
Downloaded from www.Manualslib.com manuals search engine
8.0 Warranty
This Stryker Endoscopy product is warranted to the original purchaser to be free from defects in material and workmanship for
the following times:
• One year following the date of delivery and an additional 30 days following repair
This warranty extends to all purchases and is limited to the repair or replacement of the product without charge when returned
in the original shipping case to:
Stryker Endoscopy
5900 Optical Court
San Jose, CA 95138
Stryker Endoscopy cannot accept responsibility for returns or replacements which have not been authorized. This warranty
does not cover damages caused by misuse or by failure to follow the procedures outlined in this manual or demonstrated by
Stryker Endoscopy representatives.
There are no other expressed warranties.
9.0 Service
The user is advised to return a malfunctioning unit to Stryker Endoscopy for repair or replacement, where specialized equip-
ment and technicians are available to perform repairs while maintaining full product quality and safety.
In the event that the user decides to undertake repair procedures, Stryker Endoscopy recommends that these be carried out
only by qualified technicians with proper test equipment listed in this manual, so that the safety of operators and patients may
not be compromised.
1. Contact Stryker Endoscopy at 1-800-624-4422, or call your local Stryker Endoscopy sales representative.
2. Clean and sterilize all parts that will be returned for service. Follow the instructions provided in the user manual.
3. Package all the components carefully in the original shipping container if possible.
4. Ship the product pre-paid and insured to:
Stryker Endoscopy Customer Service
Attention: Repair Department
5900 Optical Court
San Jose, CA 95138
The product described in this manual is continually being reviewed, and improvements may be made without notice.
Stryker and Stryker Endoscopy are registered trademarks of Stryker Corporation.
24
Downloaded from www.Manualslib.com manuals search engine
10.0 Other Service
For service in the U.S.A., call your Stryker Endoscopy Representative. Outside of the U.S.A., please contact your Stryker
Endoscopy distributor at one of the following locations:
25
Downloaded from www.Manualslib.com manuals search engine
Stryker Finland Stryker Middle East / Africa
PL 80 (Makelankatuz) Via Della Posta
FIN 00501 Helsinki 6934 Bioggio
FINLAND Switzerland
Phone:358 (0) 9 7744 680 Phone:(4021) 212-1122
Fax:358 (0) 9 7744 6820 Fax:(4021) 212-1133
26
Downloaded from www.Manualslib.com manuals search engine
5900 Optical Court
San Jose, CA 95138
408-754-2000
1-800-624-4422
1000-400-755 Rev. A