Mount the Sonar

The sonar images like a camera out of the front of the nose cone. It should be mounted looking forward,
preferably on the same pan-and-tilt as the ROV’s main camera.
Note: Your sonar might look different than the picture shown but the same concept applies.

Switching Sonar Heads (for the M900/2250 sonar only)


When the Connect button is clicked, the ProViewer software will automatically search for, and list, any
sonars which are connected to the PC. If more than one sonar is present, or a sonar with multiple heads
is present, ProViewer displays the available sonar heads to connect to in the Sonar and Head dropdown
menu, respectively.

Sound Speed Calibration


If an image looks broken or misaligned, the most likely cause an incorrect Sound Speed value. To access
the Sound Speed slider from within ProViewer 4, right click anywhere in the imagery window.

© Page | 3
Auto Intensity Controls
To access the extra controls un-check Auto Intensity as shown.

Shutdown
To avoid data loss, be sure to close and save any sonar data files before removing the sonar power.
When power cycling the sonar, be sure to allow at least 10 seconds of ‘off time’ before turning the sonar
back on.

User’s Manual
For the complete user’s manual, please see the manual cd, which is included with the sonar. Or you can
navigate to your sonar model online at http://www.blueview.com/products/2d-imaging-sonar/

Hardware Trigger and PPS Enabled Sonar


For the sonars with hardware triggering and/or PPS enabled refer to the user’s manual appendix for more
information.

Comments
If you have any questions or comments, please contact us.
Teledyne BlueView, Inc.
www.blueview.com
(425) 492-7400
Email: [email protected]
Part Number: 205609-00
Revision: -, April 2015
©2015 Teledyne BlueView, Inc. All rights reserved
All product names are trademarks of their respective companies

© Page | 4

You might also like