Mud Density in Out Sensor

Uploaded by

Shaukat khan
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
313 views2 pages

Mud Density in Out Sensor

Uploaded by

Shaukat khan
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

TECH SPECS SURFACE LOGGING SYSTEMS | MUD LOGGING

Mud Density In/Out Sensor


Measures the specific density of mud during drilling
operations

Applications

• Measuring mud density as it leaves (in) and returns to (out) the surface

Safety Notices

• Explosion-proof for Class I, Division I, Groups B, C, and D


• Dust-ignition-proof for Class II and Class III, Division 1, Groups E, F, and G
• Suitable for NEMA 4X indoor and outdoor hazardous locations
• Factory-sealed

Features

• Small footprint
• Industry-standard 4-20mA analog
• Power advisory diagnostic, which enables users to monitor the integrity of the
entire electrical loop

Benefits

• Capable of measuring fluid density as fluid travels in and out of the well, which
enables the user to make a direct comparison between the two values
• Suitable for use in hazardous areas as part of an intrinsically safe circuit
• Easy to configure
__________
Tool Description The mud density sensor comprises a differential
pressure sensor, which is protected by explosion-
proof housing, and two submerged pressure
The sensor provides precise measurements for a wide variety of tank
configurations. Sensors can be installed in a delta configuration to measure
both input and output density, and WellWizard® software can be used to
calculate the delta density.

© 2015 Weatherford. All rights reserved. 10925.00


TECH SPECS SURFACE LOGGING SYSTEMS | MUD LOGGING

Mud Density In/Out Sensor

Specifications

Brand Rosemount
Model 3051L
Material Aluminum
Weight 3.0 lb (1.4 kg)
Diaphragm Plezo-resistive silicon sensor
Sensor fluid Silicone fluid
Supply voltage 18 to 32 Vdc
Output signal 4 to 20 mA
Accuracy ±0.10% of span
Stability ±0.018-in. water for 5 years
Response 100 milliseconds
Sensitivity 0.0313 in. (0.80 mm) of water for 5 years
Range 0 to 20 lb/gal (0 to 2.4 sg)
Resolution 0.02 lb/gal
Location Active mud pits, return pit, header box
Operating temperature −40 to 185°F (−40 to 85°C)
Storage temperature −50 to 230°F (−46 to 110°C)
Operating humidity 0 to 100% relative humidity

weatherford.com © 2015 Weatherford. All rights reserved. 10925.00

Weatherford products and services are subject to the Company’s standard terms and conditions, available on request or at weatherford.com. For more information contact an authorized Weatherford representative. Unless noted
otherwise, trademarks and service marks herein are the property of Weatherford and may be registered in the United States and/or other countries. Weatherford products name herein may be protected by one or more U.S. and/or
foreign patents. Specifications are subject to change without notice. Weatherford sells its products and services in accordance with the terms and conditions set forth in the applicable contract between Weatherford and the client.

You might also like