520L0721 - PVBZ, Basic Module With PVP HPCO

Download as pdf or txt
Download as pdf or txt
You are on page 1of 24

MAKING MODERN LIVING POSSIBLE

Technical Information

PVBZ, Basic Module


PVP with Integrated HPCO

powersolutions.danfoss.com
Technical Information PVBZ, Basic Module - PVP with Integrated HPCO

Revision history Table of revisions

Date Changed Rev

August 2014 HPCO diagram corrected CC

May 2014 Converted to Danfoss layout – DITA CMS CB

January 2010 Drawings change page 4, 13 CA

September 2009 First edition AA

2 520L0721 • Rev CC • August 2014


Technical Information PVBZ, Basic Module - PVP with Integrated HPCO

Contents
Introduction
PVBZ...................................................................................................................................................................................................... 4
PVP with Integrated HPCO............................................................................................................................................................4
Function
Sectional view....................................................................................................................................................................................5
Function...............................................................................................................................................................................................6
Technical Data
Technical data....................................................................................................................................................................................7
PVP Pump Side Module with T0
PVP, pump side modules with T0 code numbers................................................................................................................. 8
PVBZ Basic Module with T0
PVBZ basic modules with T0 code numbers........................................................................................................................ 10
PVB Basic Module with T0
PVB basic modules with T0 code numbers...........................................................................................................................12
Standard Spools for PVBZ
End Plate PVST................................................................................................................................................................................ 13
Standard FC-spools for PVBZ (Electrical and Mechanical Actuation)..........................................................................13
Standard Float Spools for PVBZ (Electrical Actuation)......................................................................................................13
PVEH-F electrical actuation........................................................................................................................................................ 13
Hydraulic Diagram
PVG 32 with basic modules PVBZ, including integrated pilot operated check valves......................................... 14
PVG 32 with integrated HPCO (High Pressure Carry Over)............................................................................................. 15
Actuation, PVEH-F
Dimensions
Specification sheet examples
PVG 32 Specification Example for Valve Group with PVBZ.............................................................................................19
PVG 32 Specification Example for Valve Group with HPCO........................................................................................... 20

520L0721 • Rev CC • August 2014 3


Technical Information PVBZ, Basic Module - PVP with Integrated HPCO

Introduction

PVBZ
With the introduction of basic module PVBZ, Danfoss can now supply basic modules with integrated pilot
operated check valves.
The PVBZ load compensated module is developed for applications, where integrated pilot operated
check valves in the work ports are required to limit the work port leakage down to a minimum (below 1
cm3 [0.06 in3] per minute).
The new PVBZ basic module can only be mixed with basic modules PVB and PVP pumpside modules
mentioned in this Tech Note and offers the following features:
• Integrated pilot operated check valves for low internal leakage
• Integrated thermal relief valve
• Standard 4/3 spools
• 4/4 float spools
• Interchangeable spools

PVP with Integrated HPCO


Together with the introduction of PVBZ (and PVB with separate tank line T0)
Danfoss can now also supply PVG 32 valves with integrated HPCO functionality (High Pressure Carry
Over).
The HPCO function will guide the pump flow not used in the PVG 32 valve group via the HPCO port to for
example a directional valve.
The new PVP pump side module with integrated HPCO function can only be mixed with PVB, PVBZ and
PVST mentioned in this Tech Note and offers the following features:
• HPCO functionality
• Prioritized flow for PVG 32
• Reduced plumbing

4 520L0721 • Rev CC • August 2014


Technical Information PVBZ, Basic Module - PVP with Integrated HPCO

Function

Sectional view
1 2
T P

10
3
M
PVP
9
4+5
LS
11
8

7 6

12 14
B A

PVBZ

13

15

16
17
B A

PVBZ

B A

PVBZ
A

20 19 18
V310138.A

Legend:

1. Pressure relief valve 11. LS signal


2. Pressure reduction valve for pilot oil supply 12. Pilot valve for POC
3. Pressure gauge connection 13. Shuttle valve
4. Plug, open centre 14. Pilot operated check valve, POC
5. Orifice, closed centre 15. Main spool
6. Pressure adjustment spool 16. Compensator
7. Plug, closed centre 17. Shuttle pin
8. LS connection 18. Max. oil adjustment screws for ports A and B
9. T0 connection 19. Pilot supply for PVE
10. Plug to be removed for internal T0 20. Separate tank line, (T0)

520L0721 • Rev CC • August 2014 5


Technical Information PVBZ, Basic Module - PVP with Integrated HPCO

Function

(157B: 5130, 5131, 5330 and 5331 only)

Function
When main spools (15) are in neutral position, the pilot operated check valves (hereafter POC) are kept
closed by a spring plus the work port load, which is directed to the spring side of the POC (14) via a small
orifice.
If a main spool is actuated to have flow out of the B port, the meter out flow forces the respective POC
valve to open. At the same time, pilot pressure is guided via the main spool to the back side of a small
pilot valve (12) on the A port side. This will ensures, that the load pressure behind the POC is released to a
separate tank T0 (20) via a seat valve and allow the POC to open and let return flow pass across the main
spool back to tank.
For float function, both POC are released to tank at the same time like described above.
In some applications with 3/3 spools and low load pressure (eg. Hitch applications), it is necessary to
force open the POC by a pin (17). This pin is actuated by means of pump pressure on the A portside.

PVBZ modules cannot be option mounted (PVM on B - Port side).

The separate tank connection T0 is needed to ensure proper performance of the POC’ s regardless of the
pressure in main tank line T. It is therefore nessessary to connect the T0 port (9) in the Inlet PVP directly to
the oil reservoir with a separate hose.
Thermal relief valves (157B6261, 157B6262, 157B6266 157B6661, 157B6662 and 157B6666) can be
integrated to ensure that unintended high pressure between POC and cylinder/motor is not built up by
means of external heat source. The setting of the therminal relief is fixed to 276 bar [4003 psi], max.
capacity 1 l/min [0.264 US gal/min].

If tank connection T0 is not used, plug (10) must be removed. Pos 10 is not part of 157B5132, 157B5133,
157B5332 and 157B5333 and therefore T0-port (9) in 157B5132, 157B5133, 157B5332 and 157B5333 must
always be connected to tank. PVBZ can only be used in combination with PVB and PVP mentioned in this
Tech Note.

When using PVB, PVBZ and PVP (157B5140, 157B5142, 157B5340 and 157B5342 only) with separate tank
line T0 it is possible to pressurize the tank port in PVP having HPCO function.
Return flow from A and B ports of PVG 32 must be guided to tank via separate tank port in the end plate
PVST (157B2500 and 157B2520).
T0 tank port in PVP 157B5140, 157B5142, 157B5340 and 157B5342 must always be connected to tank, see
hydraulic diagram and PVG 32 Specification Example for Valve Group with HPCO for according specification.

6 520L0721 • Rev CC • August 2014


Technical Information PVBZ, Basic Module - PVP with Integrated HPCO

Technical Data

Technical data

Max. pressure Port P, continuous 210 bar [3045 psi]

Port A/B 210 bar [3045 psi]

Port T, static/dynamic 25 bar/40 bar [365/580 psi]

Oil flow, rated Port P 140 l/min [37 US gal/min]

Port A/B, with press. comp. 100 l/min [26.4 US gal/min]

Port A/B , without press. comp. 125 l/min [33 US gal/min]

Spool travel, standard ± 7 mm [±0.28 in]

Spool travel, float position spool Proportional range ± 5.5 mm [±0.22 in]

Float position 7.5 mm [±0.30 in]

Dead band, flow control spool standard ± 0.8 mm [±0.03 in]

Max. internal leakage at 200 bar [2900 psi] and 21 mm²/s [102 SUS]; A/B → T 1 cm³/min [0.06 in³/min]

Oil temperature (inlet temperature) Recommended temperature 30 → 60°C [86 → 140°F]

Min. temperature -30°C [–22°F]

Max. temperature 90°C [194°F]

Ambient temperature -30 → 60°C [–22 → 140°F]

Oil viscosity Operating range 12 - 75 mm²/s [65 - 347 SUS]

Min. viscosity 4 mm²/s [39 SUS]

Max. viscosity 460 mm²/s [2128 SUS]

Filtration / Max. contamination (ISO 4406) 18/16/13

520L0721 • Rev CC • August 2014 7


Technical Information PVBZ, Basic Module - PVP with Integrated HPCO

PVP Pump Side Module with T0

PVP, pump side modules with T0 code numbers

Symbol PVP description Code number

BSP version SAE version


LS M T0 Open centre pump side module for pumps with fixed 157B5130 157B5330
T
displacement
External T0; possible to connect T0 to internal tank
With pilot supply for electrical actuation

Pp

157-600.11

LS M T0 Closed centre pump side module for pumps with variable 157B5131 157B5331
T
displacement
External T0; possible to connect T0 to internal tank
With pilot supply for electrical actuation

Pp

157-603.11

Open centre pump side module for pumps with fixed 157B5132 157B5332
displacement
External T0
With pilot supply for electrical actuation and connection for
pilot oil pressure.
Facility for LS unloading valve, PVPX

Closed centre pump side module for pumps with variable 157B5133 157B5333
displacement
External T0
With pilot supply for electrical actuation and connection for
pilot oil pressure.
Facility for LS unloading valve, PVPX

8 520L0721 • Rev CC • August 2014


Technical Information PVBZ, Basic Module - PVP with Integrated HPCO

PVP Pump Side Module with T0

Symbol PVP description Code number

BSP version SAE version


Open centre pump side module for pumps with fixed 157B5140 157B5340
displacement
External T0
With pilot supply for electrical actuation
Blocked T line for HPCO

LS M T0 Open centre pump side module for pumps with fixed 157B5142 157B5342
HPCO
displacement
0 1
External T0
With pilot supply for electrical actuation and connection for
pilot oil pressure.
Facility for LS unloading valve, PVPX
P Blocked T line for HPCO
Pp

157-673.10

P and T-port connection: G ¾ [ 1 1∕16 in–12]

520L0721 • Rev CC • August 2014 9


Technical Information PVBZ, Basic Module - PVP with Integrated HPCO

PVBZ Basic Module with T0

PVBZ basic modules with T0 code numbers

PVBZ basic modules with T0, with thermal relief valve


Symbol PVBZ description Code No. 157B....
Max. work port pressure 210 bar [3045 psi]
BSP SAE
With compensator and thermal relief valve 6261 6661
With pilot operated check valves on work port B
Compensated work port flow A/B = 100 l/min [26.4
US gal/min]

With compensator and thermal relief valve 6262 6662


With pilot operated check valves on work port A
and B
Compensated work port flow A/B = 100 l/min [26.4
US gal/min]

With compensator and thermal relief valve 6266 6666


With pilot operated check valves on work port A
and B
LSA/B shuttle valve for float and shuttle pin
Compensated work port flow A/B = 100 l/min [26.4
US gal/min]

10 520L0721 • Rev CC • August 2014


Technical Information PVBZ, Basic Module - PVP with Integrated HPCO

PVBZ Basic Module with T0

PVBZ basic module with T0, without thermal relief valve


Symbol PVBZ description Code No. 157B....
Max. work port pressure 210 bar [3045 psi]
BSP SAE
Without thermal relief valve 6051 6451
Without compensator and load drop check valve
With pilot operated check valves on work port B

Without thermal relief valve 6052 6452


A Without compensator and load drop check valve
With pilot operated check valves on work port A
and B

T P LS Pp T0 157-586.13

Without thermal relief valve 6251 6651


With compensator
With pilot operated check valves on work port B
Compensated work port flow A/B = 100 l/min [26.4
US gal/min]

With compensator 6252 6652


With pilot operated check valves on work port A
and B
Compensated work port flow A/B = 100 l/min [26.4
US gal/min]

A and B-port connection: G ½ [7∕8 in – 14].


Seal kit for PVBZ: 157B6989

520L0721 • Rev CC • August 2014 11


Technical Information PVBZ, Basic Module - PVP with Integrated HPCO

PVB Basic Module with T0

PVB basic modules with T0 code numbers

Symbol PVB description Code number 157B.....

W/O PVLP 63 With PVLP 63

BSP SAE BSP SAE


Without load drop check valve and 6010 6410 - -
pressure compensator.
Can be used where load holding valves
prevent oil from floating back through the
channel P.

Load drop check valve 6110 6909 6140 6904

With compensator valve 6210 6922 6240 6906

With compensator valve 6213 6613 6243 6643


Adjustable LS A/B limiting valves.
External LS connection port A/B.
Also used for float position spools.

A and B-port connection: G ½ [7∕8 in – 14].

12 520L0721 • Rev CC • August 2014


Technical Information PVBZ, Basic Module - PVP with Integrated HPCO

Standard Spools for PVBZ

End Plate PVST

Code number 157B BSP SAE


G 1/2 7/8 in - 14
PVST without active 2500 2520
elements
Tank port connection
T
V310064.A

Standard FC-spools for PVBZ (Electrical and Mechanical Actuation)

Code number 157B.... Pressure compensated flow l/min [US gal/min]

Symbol 5 [1.3] 10 [2.6] 25 [6.6] 40 [10.6] 65 [17.2] 100 [26.4]


9405 9400 9401 9402 9403 9404

4-way, 3-position

Standard Float Spools for PVBZ (Electrical Actuation)

Code number 157B.... Pressure compensated flow l/min [US gal/min]

Symbol 5 [1.3] 10 [2.6] 25 [6.6] 40 [10.6] 65 [17.2] 100 [26.4]


9415 9410 9411 9412 9413 9414

4-way, 3-position
Float P > A > F

Float spools to be used in combination with PVBZ modules, 157B6266 and 157B6666 only.

PVEH-F electrical actuation

Symbol Description Code number


PVEH-F Proportional high, 157B4338*
Active fault monitoring, Multivoltage 11 - 32 V
Float P > A > F

* 6-pin AMP connector including 4 m [13 ft] cable can be ordered using code No. 157B4974.

520L0721 • Rev CC • August 2014 13


Technical Information PVBZ, Basic Module - PVP with Integrated HPCO

Hydraulic Diagram

PVG 32 with basic modules PVBZ, including integrated pilot operated check valves

14 520L0721 • Rev CC • August 2014


Technical Information PVBZ, Basic Module - PVP with Integrated HPCO

Hydraulic Diagram
PVG 32 with integrated HPCO (High Pressure Carry Over)

520L0721 • Rev CC • August 2014 15


Technical Information PVBZ, Basic Module - PVP with Integrated HPCO

Actuation, PVEH-F

Function US (pin 1) Float (pin 5)


Neutral 0.5 x UDC 0
Q: → A (0.5 → 0.25) x UDC 0
LED

Not con- Q: → B (0.5 → 0.75) x UDC 0


nected
Float None or any voltage UDC UDC
Float
Error

Proportional Proportional
Float port A Control port A Control port B

Float = Udc

16 520L0721 • Rev CC • August 2014


Technical Information PVBZ, Basic Module - PVP with Integrated HPCO

Dimensions

M
PVST
PP

125[4.92]

110[4.33]
87.5[3.445]
41.5[1.634]
4 x M8 x min.10
36.5[1.437] [4x 5 /16-18 UNC min. x 0.39]
L1 L1
L2 L2
24[0.94]

25[0.98]
3/ G 1/
G 4 2
7/
1 1/ in-12 8 -14 UNF
16

23[0.91]

81[3.12]
21[0.83]

110[4.33]
95[3.74]

95[3.74]
35[1.38]
91[3.58]

89[3.50]
P

16[0.63]
18.5[0.728]

13[0.51]
32[1.26]

34Nm[300lbf•in]
26[1.02] 26Nm[230lbf•in]
48[1.89] 21[0.83]

V310127.A

Port connections T0, M, PP, LS: G ¼ [½ in - 20]


To have easier access to fittings when building valve groups with a mix of PVB and PVBZ, it is
recommended to group PVB and PVBZ - see also PVG 32 with basic modules PVBZ, including integrated pilot
operated check valves on page 14.

PVB 1 2 3 4 5 6 7 8 9 10
L1 mm 82 130 178 226 274 322 370 418 466 514
[in] [3.23] [5.12] [7.01] [8.90] [10.79] [12.68] [14.57] [16.46] [18.35] [20.24]

520L0721 • Rev CC • August 2014 17


Technical Information PVBZ, Basic Module - PVP with Integrated HPCO

Dimensions

PVB 1 2 3 4 5 6 7 8 9 10
L2 mm 140 189 238 287 336 385 434 483 532 581
[in] [5.51] [7.44] [9.37] [11.30] [13.23] [15.16] [17.09] [19.02] [20.95] [22.87]

18 520L0721 • Rev CC • August 2014


Technical Information PVBZ, Basic Module - PVP with Integrated HPCO

Specification sheet examples

PVG 32 Specification Example for Valve Group with PVBZ

PVG 32
Specification Sheet

Subsidiary/Dealer PVG No.

Customer Customer No.

Application Revision No.

Function A-Port O 157B 5142 157B4236 B-Port

p = 210 bar 157B

a 157B 3171 1 157B 6010 157B 7001 13 157B 4901 c

b 157B LSA bar LSB bar 157B b

a 157B 3171 2 157B 6110 157B 7002 13 157B 4734 c

b 157B LSA bar LSB bar 157B b

a 157B 3193 3 157B 6210 157B 7003 13 157B 4034 c

b 157B LSA bar LSB bar 157B b

a 157B 3193 4 157B 6213 157B 7024 13 157B 4834 c

b 157B LSA 50 bar LSB 150 bar 157B b

a 157B 5 157B 157B 13 157B c

b 157B LSA bar LSB bar 157B b

a 157B 6 157B 157B 13 157B c

b 157B LSA bar LSB bar 157B b

a 157B 7 157B 157B 13 157B c

b 157B LSA bar LSB bar 157B b

a 157B 8 157B 157B 13 157B c

b 157B LSA bar LSB bar 157B b

a 157B 9 157B 157B 13 157B c

b 157B LSA bar LSB bar 157B b

a 157B 10 157B 157B 13 157B c

b 157B LSA bar LSB bar 157B b

Remarks 11 157B2500

12 157B8004

Filled in by Date

520L0721 • Rev CC • August 2014 19


Technical Information PVBZ, Basic Module - PVP with Integrated HPCO

Specification sheet examples


PVG 32 Specification Example for Valve Group with HPCO

PVG 32
Specification Sheet

Subsidiary/Dealer PVG No.

Customer Customer No.

Application Revision No.

Function A-Port O 157B 5142 157B4236 B-Port

p = 210 bar 157B

a 157B 3171 1 157B 6010 157B 7001 13 157B 4901 c

b 157B LSA bar LSB bar 157B b

a 157B 3171 2 157B 6110 157B 7002 13 157B 4734 c

b 157B LSA bar LSB bar 157B b

a 157B 3193 3 157B 6210 157B 7003 13 157B 4034 c

b 157B LSA bar LSB bar 157B b

a 157B 3193 4 157B 6213 157B 7024 13 157B 4834 c

b 157B LSA 50 bar LSB 150 bar 157B b

a 157B 5 157B 157B 13 157B c

b 157B LSA bar LSB bar 157B b

a 157B 6 157B 157B 13 157B c

b 157B LSA bar LSB bar 157B b

a 157B 7 157B 157B 13 157B c

b 157B LSA bar LSB bar 157B b

a 157B 8 157B 157B 13 157B c

b 157B LSA bar LSB bar 157B b

a 157B 9 157B 157B 13 157B c

b 157B LSA bar LSB bar 157B b

a 157B 10 157B 157B 13 157B c

b 157B LSA bar LSB bar 157B b

Remarks 11 157B2500

12 157B8004

Filled in by Date

20 520L0721 • Rev CC • August 2014


Technical Information PVBZ, Basic Module - PVP with Integrated HPCO

520L0721 • Rev CC • August 2014 21


Technical Information PVBZ, Basic Module - PVP with Integrated HPCO

22 520L0721 • Rev CC • August 2014


Technical Information PVBZ, Basic Module - PVP with Integrated HPCO

520L0721 • Rev CC • August 2014 23


Products we offer: Danfoss Power Solutions is a global manufacturer and supplier of high-quality hydraulic and
electronic components. We specialize in providing state-of-the-art technology and solutions
• Bent Axis Motors
that excel in the harsh operating conditions of the mobile off-highway market. Building on
• Closed Circuit Axial Piston our extensive applications expertise, we work closely with our customers to ensure
Pumps and Motors exceptional performance for a broad range of off-highway vehicles.
• Displays
We help OEMs around the world speed up system development, reduce costs and bring
• Electrohydraulic Power vehicles to market faster.
Steering
• Electrohydraulics Danfoss – Your Strongest Partner in Mobile Hydraulics.

• Hydraulic Power Steering Go to www.powersolutions.danfoss.com for further product information.


• Integrated Systems Wherever off-highway vehicles are at work, so is Danfoss. We offer expert worldwide support
• Joysticks and Control for our customers, ensuring the best possible solutions for outstanding performance. And
Handles with an extensive network of Global Service Partners, we also provide comprehensive global
service for all of our components.
• Microcontrollers and
Software Please contact the Danfoss Power Solution representative nearest you.
• Open Circuit Axial Piston
Pumps
• Orbital Motors
• PLUS+1® GUIDE
• Proportional Valves
• Sensors
• Steering
• Transit Mixer Drives

Comatrol
www.comatrol.com
Schwarzmüller-Inverter
www.schwarzmueller- Local address:
inverter.com
Turolla
www.turollaocg.com
Valmova
www.valmova.com
Hydro-Gear
www.hydro-gear.com
Daikin-Sauer-Danfoss
www.daikin-sauer-danfoss.com

Danfoss
Power Solutions
Danfoss Danfoss Danfoss (Shanghai) Co., Ltd.
Power Solutions US Company Power Solutions GmbH & Co. OHG Power Solutions ApS Building #22, No. 1000 Jin Hai Rd
2800 East 13th Street Krokamp 35 Nordborgvej 81 Jin Qiao, Pudong New District
Ames, IA 50010, USA D-24539 Neumünster, Germany DK-6430 Nordborg, Denmark Shanghai, China 201206
Phone: +1 515 239 6000 Phone: +49 4321 871 0 Phone: +45 7488 2222 Phone: +86 21 3418 5200

Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to
products already on order provided that such alterations can be made without changes being necessary in specifications already agreed.
All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.

520L0721 • Rev CC • August 2014 www.danfoss.com © Danfoss A/S, 2014

You might also like