520L0721 - PVBZ, Basic Module With PVP HPCO
520L0721 - PVBZ, Basic Module With PVP HPCO
520L0721 - PVBZ, Basic Module With PVP HPCO
Technical Information
powersolutions.danfoss.com
Technical Information PVBZ, Basic Module - PVP with Integrated HPCO
Contents
Introduction
PVBZ...................................................................................................................................................................................................... 4
PVP with Integrated HPCO............................................................................................................................................................4
Function
Sectional view....................................................................................................................................................................................5
Function...............................................................................................................................................................................................6
Technical Data
Technical data....................................................................................................................................................................................7
PVP Pump Side Module with T0
PVP, pump side modules with T0 code numbers................................................................................................................. 8
PVBZ Basic Module with T0
PVBZ basic modules with T0 code numbers........................................................................................................................ 10
PVB Basic Module with T0
PVB basic modules with T0 code numbers...........................................................................................................................12
Standard Spools for PVBZ
End Plate PVST................................................................................................................................................................................ 13
Standard FC-spools for PVBZ (Electrical and Mechanical Actuation)..........................................................................13
Standard Float Spools for PVBZ (Electrical Actuation)......................................................................................................13
PVEH-F electrical actuation........................................................................................................................................................ 13
Hydraulic Diagram
PVG 32 with basic modules PVBZ, including integrated pilot operated check valves......................................... 14
PVG 32 with integrated HPCO (High Pressure Carry Over)............................................................................................. 15
Actuation, PVEH-F
Dimensions
Specification sheet examples
PVG 32 Specification Example for Valve Group with PVBZ.............................................................................................19
PVG 32 Specification Example for Valve Group with HPCO........................................................................................... 20
Introduction
PVBZ
With the introduction of basic module PVBZ, Danfoss can now supply basic modules with integrated pilot
operated check valves.
The PVBZ load compensated module is developed for applications, where integrated pilot operated
check valves in the work ports are required to limit the work port leakage down to a minimum (below 1
cm3 [0.06 in3] per minute).
The new PVBZ basic module can only be mixed with basic modules PVB and PVP pumpside modules
mentioned in this Tech Note and offers the following features:
• Integrated pilot operated check valves for low internal leakage
• Integrated thermal relief valve
• Standard 4/3 spools
• 4/4 float spools
• Interchangeable spools
Function
Sectional view
1 2
T P
10
3
M
PVP
9
4+5
LS
11
8
7 6
12 14
B A
PVBZ
13
15
16
17
B A
PVBZ
B A
PVBZ
A
20 19 18
V310138.A
Legend:
Function
Function
When main spools (15) are in neutral position, the pilot operated check valves (hereafter POC) are kept
closed by a spring plus the work port load, which is directed to the spring side of the POC (14) via a small
orifice.
If a main spool is actuated to have flow out of the B port, the meter out flow forces the respective POC
valve to open. At the same time, pilot pressure is guided via the main spool to the back side of a small
pilot valve (12) on the A port side. This will ensures, that the load pressure behind the POC is released to a
separate tank T0 (20) via a seat valve and allow the POC to open and let return flow pass across the main
spool back to tank.
For float function, both POC are released to tank at the same time like described above.
In some applications with 3/3 spools and low load pressure (eg. Hitch applications), it is necessary to
force open the POC by a pin (17). This pin is actuated by means of pump pressure on the A portside.
The separate tank connection T0 is needed to ensure proper performance of the POC’ s regardless of the
pressure in main tank line T. It is therefore nessessary to connect the T0 port (9) in the Inlet PVP directly to
the oil reservoir with a separate hose.
Thermal relief valves (157B6261, 157B6262, 157B6266 157B6661, 157B6662 and 157B6666) can be
integrated to ensure that unintended high pressure between POC and cylinder/motor is not built up by
means of external heat source. The setting of the therminal relief is fixed to 276 bar [4003 psi], max.
capacity 1 l/min [0.264 US gal/min].
If tank connection T0 is not used, plug (10) must be removed. Pos 10 is not part of 157B5132, 157B5133,
157B5332 and 157B5333 and therefore T0-port (9) in 157B5132, 157B5133, 157B5332 and 157B5333 must
always be connected to tank. PVBZ can only be used in combination with PVB and PVP mentioned in this
Tech Note.
When using PVB, PVBZ and PVP (157B5140, 157B5142, 157B5340 and 157B5342 only) with separate tank
line T0 it is possible to pressurize the tank port in PVP having HPCO function.
Return flow from A and B ports of PVG 32 must be guided to tank via separate tank port in the end plate
PVST (157B2500 and 157B2520).
T0 tank port in PVP 157B5140, 157B5142, 157B5340 and 157B5342 must always be connected to tank, see
hydraulic diagram and PVG 32 Specification Example for Valve Group with HPCO for according specification.
Technical Data
Technical data
Spool travel, float position spool Proportional range ± 5.5 mm [±0.22 in]
Max. internal leakage at 200 bar [2900 psi] and 21 mm²/s [102 SUS]; A/B → T 1 cm³/min [0.06 in³/min]
Pp
157-600.11
LS M T0 Closed centre pump side module for pumps with variable 157B5131 157B5331
T
displacement
External T0; possible to connect T0 to internal tank
With pilot supply for electrical actuation
Pp
157-603.11
Open centre pump side module for pumps with fixed 157B5132 157B5332
displacement
External T0
With pilot supply for electrical actuation and connection for
pilot oil pressure.
Facility for LS unloading valve, PVPX
Closed centre pump side module for pumps with variable 157B5133 157B5333
displacement
External T0
With pilot supply for electrical actuation and connection for
pilot oil pressure.
Facility for LS unloading valve, PVPX
LS M T0 Open centre pump side module for pumps with fixed 157B5142 157B5342
HPCO
displacement
0 1
External T0
With pilot supply for electrical actuation and connection for
pilot oil pressure.
Facility for LS unloading valve, PVPX
P Blocked T line for HPCO
Pp
157-673.10
T P LS Pp T0 157-586.13
4-way, 3-position
4-way, 3-position
Float P > A > F
Float spools to be used in combination with PVBZ modules, 157B6266 and 157B6666 only.
* 6-pin AMP connector including 4 m [13 ft] cable can be ordered using code No. 157B4974.
Hydraulic Diagram
PVG 32 with basic modules PVBZ, including integrated pilot operated check valves
Hydraulic Diagram
PVG 32 with integrated HPCO (High Pressure Carry Over)
Actuation, PVEH-F
Proportional Proportional
Float port A Control port A Control port B
Float = Udc
Dimensions
M
PVST
PP
125[4.92]
110[4.33]
87.5[3.445]
41.5[1.634]
4 x M8 x min.10
36.5[1.437] [4x 5 /16-18 UNC min. x 0.39]
L1 L1
L2 L2
24[0.94]
25[0.98]
3/ G 1/
G 4 2
7/
1 1/ in-12 8 -14 UNF
16
23[0.91]
81[3.12]
21[0.83]
110[4.33]
95[3.74]
95[3.74]
35[1.38]
91[3.58]
89[3.50]
P
16[0.63]
18.5[0.728]
13[0.51]
32[1.26]
34Nm[300lbf•in]
26[1.02] 26Nm[230lbf•in]
48[1.89] 21[0.83]
V310127.A
PVB 1 2 3 4 5 6 7 8 9 10
L1 mm 82 130 178 226 274 322 370 418 466 514
[in] [3.23] [5.12] [7.01] [8.90] [10.79] [12.68] [14.57] [16.46] [18.35] [20.24]
Dimensions
PVB 1 2 3 4 5 6 7 8 9 10
L2 mm 140 189 238 287 336 385 434 483 532 581
[in] [5.51] [7.44] [9.37] [11.30] [13.23] [15.16] [17.09] [19.02] [20.95] [22.87]
PVG 32
Specification Sheet
Remarks 11 157B2500
12 157B8004
Filled in by Date
PVG 32
Specification Sheet
Remarks 11 157B2500
12 157B8004
Filled in by Date
Comatrol
www.comatrol.com
Schwarzmüller-Inverter
www.schwarzmueller- Local address:
inverter.com
Turolla
www.turollaocg.com
Valmova
www.valmova.com
Hydro-Gear
www.hydro-gear.com
Daikin-Sauer-Danfoss
www.daikin-sauer-danfoss.com
Danfoss
Power Solutions
Danfoss Danfoss Danfoss (Shanghai) Co., Ltd.
Power Solutions US Company Power Solutions GmbH & Co. OHG Power Solutions ApS Building #22, No. 1000 Jin Hai Rd
2800 East 13th Street Krokamp 35 Nordborgvej 81 Jin Qiao, Pudong New District
Ames, IA 50010, USA D-24539 Neumünster, Germany DK-6430 Nordborg, Denmark Shanghai, China 201206
Phone: +1 515 239 6000 Phone: +49 4321 871 0 Phone: +45 7488 2222 Phone: +86 21 3418 5200
Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to
products already on order provided that such alterations can be made without changes being necessary in specifications already agreed.
All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.