998 20845418 EectricalDistribution GMA Catalogue2021 A DE3-NancyEW p81-131 en

Download as pdf or txt
Download as pdf or txt
You are on page 1of 51

Circuit Breakers

Selection Guide

Description Page
Selection Information DE3-2

QO™ and QOU Miniature Circuit Breakers DE3-10

QO™ Miniature Circuit Breakers DE3-10


QO™ Circuit Breaker Accessories DE3-12
B-Frame H-Frame QO™ and Multi 9™ Mounting Bases DE3-13
QOU Miniature Circuit Breakers DE3-14
QOU Accessories DE3-15

Multi 9™ Miniature Circuit Breakers DE3-16

Molded Case Circuit Breakers

CIRCUIT BREAKERS
DE3-19

PowerPact Family DE3-19


B-Frame Circuit Breakers DE3-20
H- and J-Frame Circuit Breakers DE3-21
J-Frame L-Frame
Q-Frame Circuit Breakers DE3-23
Q4, LA, LH Circuit Breakers DE3-24

DE3
L-Frame Circuit Breakers DE3-25
M-Frame Circuit Breakers DE3-26
P-Frame Circuit Breakers DE3-27
R-Frame Circuit Breakers DE3-28

Motor Circuit Protectors DE3-29

Automatic Switches DE3-31

500 Vdc Circuit Breakers DE3-32


M-Frame
PowerPact™ Circuit Breaker Accessories DE3-33

Micrologic™ Electronic Trip Units DE3-40

Dimensions and Shipping Weights DE3-44

Circuit Breaker Enclosures DE3-46

CDP connector kits DE3-50

P-Frame

R-Frame

08/21
DE3-1
08/21
Selection Information
Miniature Circuit Breakers Class 500, 600

CHOM Circuit Breakers QO™ Circuit Breakers

CHOM CHOM- CHOM- CHOM- CHOM- CHOMT QOT QO- VHCAFI QO-GFI
QO- QO- QO-EPD QO-DF QOVH-
Plug-on QO QO-H QO-VH QH
CAFI DF GFI EPD CAFI VHGFI QO-EPE DF
Circuit
Breaker Bolt-on — — — — — — — — — QOB QOB-H — — —
QOB-
QHB —
QOB- QOB- QOB- QOB-EPD
Type VH CAFI VCHAFI QOB-GFI VHGFI QOB-EPE — —

Unit Mount — — — — — — — — — — — — — — — — — — — — — — — — — — — — — —

Number of Poles 1 2 1,2 1 1 2 1 2 1 1 2 3 2 1 2 3 1 2, 3 1,2 3 1 1 1,2 1 2 3 1 1 2 3 1 1


a
CIRCUIT BREAKERS

15–200k

10–200k
15–50b

10–100

15–100

15–125
15–100

15–150
15–50

15–20

15–20

15–20
15–50
15–20
15–50

10–70

15–30

15–30

15–30
15–30

15–30

15–20

15–30

15–30
15–60
15–50

15–30

15–30
15–60
15–50

15–20

15–20
Current Range

Interrupting Ratings
120 Vac 10 10 10 10 10 10 10 10 10 10 10 10 10 22 22 22 22 22 65 65 10 10 22 10 10 — 22 10 10 — 10 22
120/240 Vac 10 10 — — — 10 — 10 10 10 10 10 10 22 22 22 22 22 65 65 10 — — — 10 — — — 10 — — —
UL/CSA 208Y/120 — — — — — — — — — — — — — — — — — — — — — — — — — 10 — — — — — —
Rating
(kA) 240 Vac d — — — — — — — — — — — 10 10 — — 22 — 22 d — 65 — — — — — — — — — 10 — —
(50/60 Hz)
277 Vac — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — —
DE3

480Y/277 Vac — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — —
48 Vdc — — — — — — — — — 5e 5e5e — — — — — — — — — — — — — — — — — — — —
60 Vdc — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — —
DC Ratings 65 Vdc — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — —
125 Vdc — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — —
250 Vdc — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — —
IEC 60947-2 IEC — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — —
(50/60 Hz)e (Icu) — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — —
Special Ratings
CCC — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — —
Fed. Specs
W-C-375B/GEN X X X X X X X X X X — — — X — — — — X — X X — X — — X — X X
HACR f HACRg HACR HACR HACR
Other Standard NOM HACR f NOM HACR g — — — g — NOM — NOM g g
Accessories and Modifications
Shunt Trip h — — — — — — — — — X X X X X X X X Xi X X X — — — — — — — — — — —
Undervoltage Trip — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — —
Auxiliary Switches h — — — — — — — — — X X X X X X X X Xi X X X — X X X X X X X X — —
Alarm Switch h — — — — — — — — — X X X X X X X X Xi X X X — X X X X X X X X — —
Handle Operators — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — —
Handle Padlock X
Attachment X X X X — — — — Xj X X X X X X X X X X X X X X X X X X X X X X

Trip System Type


Thermal-magnetic X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X
Molded Case Switch — — — — — — — — — X X X — — — — — — — — — — — — — — — — — — — —
Dimensions (1P Unit Mount)

Dimensions Height 3.13 (79) 3.5 (89) a 4.75 (121) 4.12 (103)
(1P Unit Mount) Width 1.00 (25) 0.75 (19) a
in. (mm) Depth 2.98 (76) 2.92 (74) a
Pages Section DE1 Pages DE3-10, DE3-11
a See page DE3-53 for dimensions for: QOB2150VH, QOB3110VH, QOB3125VH and QOB3150VH.
b CHOMT tandem is 30 A maximum. CHOMT quad has 20 A maximum on outside poles, and 50 A maximum on the inside poles.
c AFI, EPD and GFI products are rated 60 Hz only.
d 22 kA @ 240 Vac for 3P only.
e 1P and 2P, 10–70 A and 3P 10–60 A only.
f HACR on CHOM 1P 15–50 A and 2P 15–100 A
g HACR on QO, QOB 1P 10–70 A, 2P 15–100 A, 3P 10–100 A; QOB-VH 1P 15–70 A, 2P 15–125 A, 3P 15–100 A.
h Factory-installed option only.
i Factory-installed accessories are not available on QOB-VH 2P150 A and 3P 110–150 A.
j Handle padlock attachment available for CHOMT quad tandem only.
k 2P 150–200 A requires 4P width.

11/18
DE3-2
08/21
Selection Information
Class 500, 600 Miniature Circuit Breakers

QOU QOM1 and QOM2 Main Multi 9™ Circuit Breakers and EDB Circuit Breakers
Circuit Breakers Circuit Breakers Supplementary Protectors

Plug-on — — — — — — — —
Circuit
Bolt-on — QOM1-VH QOM2-VH — — EDB EGB EJB
Breaker
Type
Unit Mount QOU — — CSA C22.2 No. 5/UL 489 CSA C22.2 No. 235/UL1077 — — —
C60BP/BPR C60SP
Number of Poles 1 2 3 2 2 1 2 3 1 2 3,4 2,3,4 1 2, 3 1 2, 3 1 2, 3
100–225
10–100

10–125

10–100

50–125

0.5–35

0.5–32

15–70

15–70

15–70
30-35

40-63

40-63

40-63

40-63

15–125

15–125

15–125
1–25

1–35

1–25

2–32
Current Range

32

CIRCUIT BREAKERS
Interrupting Ratings
120 Vac 10 10 10 22 22 14 — — — — — 14 10 — — — — 25 25 65 65 100 100
120/240 Vac 10 10 10 22 22 14 — — — — — 14 10 — — — — 18 25 35 65 65 100
UL/CSA 240 Vac — — 10 — — 14 14 14 10 14 10 14 10 14 14 14 10 18 25 35 65 65 100
Rating 277 Vac — — — — — 10 10 10 — 10 — 10 5 10 10 10 5 18 18 35 35 65 65
(kA RMS)
(50/60 Hz) 377 Vac — — — — — — — — — — — — — — — — — 14 — 18 — 25 —
480Y/277 Vac — — — — — — 10 10 — 10 — — — 10 10 10 5 — 18 — 35 — 65
600Y/347 Vac — — — — — — — — — — — — — — — — — — 14 — 18 — 25
48 Vdc 5b 5b 5b — — — — — — — — — — — — — — — — — — — —

DE3
60 Vdc 5c 5c 5c — — 10 — — — — — — — — — — — — — — — — —
65 Vdc — — — — — — — — — — — 10 10 — — — — — — — — — —
DC Ratings
125 Vdc — — — — — — 10 — — — — — — 10 — — — — — — — — —
250 Vdc — — — — — — — — — — — — — — — — — — — — — — —
500 Vdc — — — — — — — — — — — — — — — — — — — — — — —
IEC 60947-2 240 Vac — — — — — 10 20 20 20 20 20 10 10 20 20 20 20 20 — — — — —
(50/60 Hz)
Icu 415 Vac — — — — — 3 10 10 10 10 10 3 3 10 10 10 10 10 — — — — —
Special Ratings
CCC Xg Xg Xg — — X X X X X X X X X X X X — — — — — —
Fed. Specs X X X X X X X X X X X — — — — — — X X X X X X
W-C-375B/GEN
Other Standard HACR d — — GB GB GB GB GB GB GB GB GB GB GB GB HACR
Accessories and Modifications
Shunt Trip Xe Xe Xe — X e X X X X X X X X X X X X X e X e X e X e X e X e
Undervoltage Trip — — — — — X X X X X X X X X X X X — — — — — —
Auxiliary Switches Xe Xe Xe — — X X X X X X X X X X X X Xe Xe Xe Xe Xe Xe
Alarm Switch Xe Xe Xe — — X X X X X X X X X X X X Xe Xe Xe Xe Xe Xe
Handle Operators — — — — — X X X X X X X X X X X X — — — — — —
Handle Padlock
Attachment X X X X X X X X X X X X X X X X X X X X X X X

Trip System Type


Thermal-magnetic X X X X X X X X X X X X X X X X X X X X X X X
Molded Case Switch — X X — — — — — — — — — — — — — — — — — — — —
Dimensions (1P Unit Mount)
Dimensions Height 4.05 (103) 5.09 (129)f 5.60 (142)f 4.06 (103) 3.19 (81) 5.66 (144)
(1P Unit Mount) Width 0.75 (19) 5.00 (127)f 5.07 (129)f 0.71 (18) 0.71 (18) 0.98 (25)
in. (mm) Depth 2.92 (74) 3.47 (88)f 3.60 (91)f 2.83(72) 2.83 (72) 4.05 (103)
Pages Pages DE3-14 Section DE1 Pages DE3-16 through DE3-18 Section DE5
Note: All circuit breakers on this chart are UL Listed and CSA Certified unless otherwise noted.
a C60H-DC is a UL 1077 (not CSA certified) supplementary protector.
b 1P and 2P, 10–70 A and 3P 10–60 A only.
c QOU is CSA/UL Listed for 60 Vdc per pole 80–100 A, 1P; 80–125 A, 2P; and 70–100 A, 3P.
d HACR on QOU 1P and 3P 15–100 A, 2P 15–125 A;
e Factory-installed option only
f QOM1 and QOM2 dimensions are for 2-pole unit.
g 15–70 A 1P and 2P, 15–60 A 3P.
h 100 A maximum at 600Y/347 Vac

11/18
DE3-3
08/21
Selection Information
Molded Case Circuit Breakers

PowerPact™ 125 A B-Frame PowerPact™ 150 A H-Frame PowerPact 250 A J-Frame

Circuit Breaker Type BD BG BJ BK HD HG HJ HL HR JD JG JJ JL JR


Number of Poles [1] 1, 2, 3, 4 1, 2, 3, 4 1, 2, 3, 4 1, 2 2, 3 2, 3 2a, 3 2a, 3 — 2a, 3 2a, 3 2a, 3 2a, 3 3
Current Range, A [1] 15-125 15-125 15-125 15-125 15-150 15-150 15-150 15-150 — 150-250 150-250 150-250 150-250 150-250
Number of Poles [2] — — — — 3 3 3 3 3 3 3 3 3 3
Current Range, A [2] — — — 15-150 15-150 15-150 15-150 15-150 70-250 70-250 70-250 70-250 70-250
CIRCUIT BREAKERS

Interrupting Ratings
240 Vac 25 65 100 100 25 65 100 125 200 25 65 100 125 200
UL/CSA/NOM
480Y/277 Vac 18 35 65 65 18 35 65 100 200 18 35 65 100 200
Rating
480 Vac 18 35 65 65 18 35 65 100 200 18 35 65 100 200
(kARMS)
600Y/347 Vac 14 18 25 65 14 18 25 50 100 14 18 25 50 100
(50/60Hz)
600 Vac — — — — 14 18 25 50 100 14 18 25 50 100
250 Vdcc 10 20 50 — 20 20 20 20 — 20 20 20 20 —
DC Ratings
500 Vdcc — — — — — 20 — 50 — — 20 — 50 —
220/240 Vac 25 65 100 100 25 65 100 125 150 25 65 100 125 150
IEC AC Rating
380/415 Vac 18 35 65 65 18 35 65 100 125 18 35 65 100 125
(kA RMS)
DE3

440/480 Vac 18 35 65 65 18 35 65 100 125 18 18 25 50 125


(50/60Hz)
500/525 Vac 14 18 25 25 14 18 25 50 75 14 20 20 20 75
Icu/lcsd
690 Vac — — — — — — — — 20 — — — — 20
250 Vdc — — — — — — — — — 20 20 20 20 —
IEC DC Ratings
500 Vdc — — — — — — — — — 20 20 20 20 —
Special Ratings
CCC X X X X X X X X X X X X X X
Fed. Specs W-C-375B/GEN X X X X X X X X X X X X X X
HACR X X X X X X X X X X X X X X
Connections/Terminations
Unit Mount X X X X X X X X X X X X X X
I-Line™ X X X X X X X X X X X X X X
Rear Connection — — — — Xe Xe X X X X X X X X
Drawout — — — — Xe Xe X X X X X X X X
Optional Lugs X X X X Xe Xe X X X X X X X X
Accessories and Modifications
Shunt Trip X X X X X X X X X X X X X X
Undervoltage Trip X X X X X X X X X X X X X X
Auxiliary Switches X X X X X X X X X X X X X X
Alarm Switch X X X X X X X X X X X X X X
Motor Operator — — — — Xe Xe X X X X X X X X
Handle Operators X X X X Xe Xe X X X X X X X X
Mechanical Interlocks (3P) X X X — X X X X X X X X X X
Handle Padlock Attachment X X X X Xe Xe X X X X X X X X
Cylinder Lock (3P) — — — — — — — — — — — — — —
Optional GF Protection — — — — — — — — — — — — — —
Trip System Type
Thermal-magnetic X X X X X X X X — X X X X X
Instantaneous-only (MCP) — — — — — — Xf Xf X — — Xf Xf X
Molded Case Switch (Automatic) X X X — — X — X — — X — X X
Enclosures (Pages DE3-46–DE3-49)
General Purpose (NEMA 1) X X X X X X X X** — X X X X** —
Raintight (NEMA 3R) X X X X X X X X** — X X X X** —
Dust-tight (NEMA 12) X X X X X X X X** — X X X X** —
Watertight (NEMA 4, 4X, 5) X X X X X X X X** — X X X X** —
Explosion Proof (NEMA 7,9) X X X X — — — — — Xg Xg — — —
Dimensions Height 5.4 (137) 6.4 (163) 7.5 (191)
(3P Unit Mount) Width 3.2 (81) 4.1 (104) 4.1 (104)
in. (mm) Depth 3.5 (89) 3.4 (86) 3.4 (86)
Pages (UnitMount)/(I-Line) Page DE3-20/Section DE5 Pages DE3-21, DE3-22/Section DE5 Pages DE3-21, DE3-22/Section DE5

Note: All circuit breakers on this chart are UL Listed and CSA Certified unless otherwise noted.
a 2P in a 3P module
[1] MCCB with thermal magnetic trip unit
[2] MCCB with electronic trip unit
c Not available with electronic trip units. 125 Vdc for 1P PowerPact B
d Dual CSA/UL and IEC ratings and CE markings on circuit breakers
e Not available in HD and HG 2P rating (2P module)
f 3P only
g Not UL Listed due to wire bending space
** 25 kA at 600 Vac; 20 kA at 250 Vdc

08/21
DE3-4
Selection Information
Molded Case Circuit Breakers

250 A Q-Frame Q4, LA, LH

Circuit Breaker Type QB QD QG QJ Q4 LA LH


Number of Poles [1] 2, 3 2, 3 2, 3 2, 3 2a, 3 2a, 3 2a, 3
Current Range, A [1] 70-250[3] 70-250[3] 70-250[3] 70-250[3] 125-400 125-400 125-400
Number of Poles [2] — — — — — — —
Current Range, A [2] — — — — — — —

CIRCUIT BREAKERS
Interrupting Ratings
240 Vac 10 25 65 100 25 42 65
UL/CSA/NOM
480Y/277 Vac — — — — — 30 35
Rating
480 Vac — — — — — 30 35
(kARMS)
600Y/347 Vac — — — — — 22 25
(50/60Hz)
600 Vac — — — — — 22 25
250 Vdci — — — — — 10 50
DC Ratings
500 Vdcci — — — — — — —
220/240 Vac 10/5 10/5 10/5 10/5 — — —
IEC AC Rating
380/415 Vac 10/5 10/5 10/5 10/5 — 20/5 20/5
(kA RMS)

DE3
440/480 Vac — — — — — — —
(50/60Hz)
500/525 Vac — — — — — — —
Icu/lcsd
690 Vac — — — — — — —
250 Vdc — — — — — — —
IEC DC Ratings
500 Vdc — — — — — — —
Special Ratings
CCC — — — — — — —
Fed. Specs W-C-375B/GEN X X X X X X X
HACR (2P, 3P) X X X — — X X
Connections/Terminations
Unit Mount X X X X X X X
I-Line™ X X X X X X X
Rear Connection — — — — X X X
Drawout — — — — — — —
Optional Lugs — — — — X X X
Accessories and Modifications
Shunt Trip — — — — X X X
Undervoltage Trip — — — — X X X
Auxiliary Switches — — — — X X X
Alarm Switch — — — — X X X
Motor Operator — — — — X X X
Handle Operators — — — — X X X
Mechanical Interlocks (3P) X X X X — X[4] X[4]
Handle Padlock Attachment X X X X X X X
Cylinder Lock (3Pf) — — — — X X X
Optional GF Protection — — — — — — —
Trip System Type
Thermal-magnetic X X X X X X X
Instantaneous-only (MCP) — — — — — X X
Molded Case Switch (Automatic) X — — — — — X
Electronic — — — — — — —
Enclosures (Pages DE3-46–DE3-49)
General Purpose (NEMA 1) X X X X X X X
Raintight (NEMA 3R) X X X X X X X
Dust-tight (NEMA 12) — — — — X X X
Watertight (NEMA 4, 4X, 5) — — — — X X X
Explosion Proof (NEMA 7,9) — — — — — — —
Dimensions Height 6.47 (164) 11 (279)
(3P Unit Mount) Width 4.5 (114) 6 (152)
in. (mm) Depth 3.93 (100) 5.84 (148)
Pages (UnitMount)/(I-Line) Pages DE3-23/Section DE5 DE3-24/Section DE5

a 2P in a 3P module
[1] MCCB with thermal magnetic trip unit
[2] MCCB with electronic trip unit
[3] I-Line Q-frame circuit breakers are available 70–225A only. 250A
Q-frame unit-mount circuit breakers are limited to Cu conductors only
[4] Requires circuit breaker with WB suffix
d Dual CSA/UL and IEC ratings and CE markings on circuit breakers
f Factory-installed optiononly
g 3P only
i Not available with electronic trip units

08/21
DE3-5
Selection Information
Molded Case Circuit Breakers

PowerPact™ 600 A L-Frame

Circuit Breaker Type LD LG LJ LL LR


Number of Poles [1] — — — — —
Current Range, A [1] — — — — —
Number of Poles [2] 3, 4 3, 4 3, 4 3, 4 3, 4
Current Range, A [2] 70-600 70-600 70-600 70-600 70-600
CIRCUIT BREAKERS

Interrupting Ratings
240 Vac 25 65 100 125 200
UL/CSA/NOM
480Y/277 Vac 18 35 65 100 200
Rating
480 Vac 18 35 65 100 200
(kARMS)
600Y/347 Vac 14 18 25 50 100
(50/60Hz)
600 Vac 14 18 25 50 100
250 Vdci — — — — —
DC Ratings
500 Vdcci — 20 — 50 —
220/240 Vac 25 65 100 125 150
IEC AC Rating
380/415 Vac 18/18 18 65 100 125
(kA RMS)
440/480 Vac 18/18 18 65 100 125
DE3

(50/60Hz)
500/525 Vac 18/18 14 25 50 125
Icu/lcsd
690 Vac — — — — 20
250 Vdc — — — — —
IEC DC Ratings
500 Vdc — — — — —
Special Ratings
CCC X X X X X
Fed. Specs W-C-375B/GEN — — — — —
HACR (2P, 3P) X X X X X
Connections/Terminations
Unit Mount X X X X X
I-Line™ X X X X X
Rear Connection X X X X X
Drawout X X X X X
Optional Lugs X X X X X
Accessories and Modifications
Shunt Trip X X X X X
Undervoltage Trip X X X X X
Auxiliary Switches X X X X X
Alarm Switch X X X X X
Motor Operator X X X X X
Handle Operators X X X X X
Mechanical Interlocks (3P) X X X X X
Handle Padlock Attachment X X X X X
Cylinder Lock (3Pf) — — — — —
Optional GF Protection X X X X X
Trip System Type
Thermal-magnetic — — — — —
Instantaneous-only (MCP) X X X X X
Molded Case Switch (Automatic) — X — X X
Electronic X X X X X
Enclosures (Pages DE3-46–DE3-49)
General Purpose (NEMA 1) — — — — —
Raintight (NEMA 3R) — — — — —
Dust-tight (NEMA 12) X X X X X
Watertight (NEMA 4, 4X, 5) — — — — —
Explosion Proof (NEMA 7, 9) — — — — —
Dimensions Height 13.38 (340)
(3P Unit Mount) Width 5.51 (140)
in. (mm) Depth 4.33 (110)
Pages (UnitMount)/(I-Line) DE3-25/Section DE5

[1] MCCB with thermal magnetic trip unit


[2] MCCB with electronic trip unit
c Ungrounded UPS systems only. See page DE3-35
d Dual CSA/UL and IEC ratings and CE markings on circuit breakers
i Not available with electronic trip units

08/21
DE3-6
Selection Information
Molded Case Circuit Breakers

PowerPact 800 A M-Frame PowerPact 1200 A P-Frame PowerPact 3000 A R-Frame

Circuit Breaker Type MG MJ PG PJ PK PL RG RJ RK RL


Number of Poles 2, 3 2, 3 2, 3, 4 2, 3 2, 3, 4 2, 3 2, 3, 4 2, 3, 4 2, 3, 4 2, 3, 4
Current Range 300–800 300–800 100–1200 100–1200 100–1200 100–1200 240–3000 240–3000 240–3000 240–3000
Interrupting Ratings
240 Vac 65 100 65 100 65 125 65 100 65 125

BREAKERS
UL/CSA/NOM 480Y/277 Vac 35 65 35 65 50 100 35 65 65 100

CIRCUITBREAKERS
Rating
(kA RMS) 480 Vac 35 65 35 65 50 100 35 65 65 100
(50/60 Hz) 600Y/347 Vac 18 25 18 25 50 25 18 25 65 50
600 Vac 18 25 18 25 50 25 18 25 65 50
250 Vdc — — — — — — — — — —

CIRCUIT
DC Ratings
500 Vdca — — — — — — — — — —
IEC 240 Vac 50/25 65/35 50/25 65/35 50/25 125/65 50/25 65/35 85/65 125/65
(kA RMS)
Icu/lcsb 415 Vac 35/20 50/25 35/20 50/25 50/25 85/45 35/20 50/25 70/55 85/45

DE3
Special Ratings

DE3
CCC X X X X X X X X X X
Fed. Specs W-C-375B/GEN X X X X X X X X X X
HACR (2P, 3P) X X X X X X X X X X
Connections/Terminations
Unit Mount X X X X X X X X X X
I-Line™ X X X X X X Xe Xe Xe Xe
Rear Connection — — — — — — — — — —
Drawout — — Xd Xd Xd Xd — — — —
Optional Lugs X X X X X X X X X X
Accessories and Modifications
Shunt Trip X X X X X X X X X X
Undervoltage Trip X X X X X X X X X X
Auxiliary Switches X X X X X X X X X X
Alarm Switch X X X X X X X X X X
Motor Operator — — Xd Xd Xd Xd — — — —
Handle Operators — — Xd Xd Xd Xd — — — —
Mechanical Interlocks (3P) — — X X X X — — — —
Handle Padlock Attachment X X X X X X X X X X
Cylinder Lock (3P) — — — — — — — — — —
Optional GF Protection — — X X X X X X X X
Trip System Type
Thermal-magnetic — — — — — — — — — —
Instantaneous-only (MCP) — — — X X — — — — —
Molded Case Switch (Automatic) — — X X X X X X X X
Electronic X X X X X X X X X X
Enclosures (Pages DE3-46–DE3-49)
General Purpose (NEMA 1) X X X X X X — — — —
Raintight (NEMA 3R) X X X X X X — — — —
Dust-tight (NEMA 12) X X X X X X — — — —
Watertight (NEMA 4, 4X, 5) X X — — — — — — — —
Explosion Proof (NEMA 7, 9) — — — — — — — — — —
Height–in. (mm) 12.80 (325) 16.20 (413) 15 (381)
Dimensions
Width—in. (mm) 8.30 (210) 8.30 (210) 16.50 (420)
(3P Unit Mount)
Depth—in. (mm) 8.10 (205) 8.10 (205) 14.40 (366)
Pages (Unit Mount)/(I-Line) Page DE3-26/Section DE5 Page DE3-27, /Section DE5 Page DE3-28, /Section DE5
Note: All circuit breakers on this chart are UL Listed and CSA Certified unless otherwise noted.
a Ungrounded UPS systems only. See page DE3-32.
b Dual CSA/UL and IEC ratings and CE markings on circuit breakers.
d 65/50 kA Icu/Ics for 450–600 A ratings.
e 1000 A and 1200 A only.

DE3-7
08/21
Selection Information
Insulated Case Circuit Breakers

Masterpact 1200 A MTZ1 Masterpact 3000 A MTZ2 Masterpact 6000 A MTZ3

Circuit Breaker Type MTZ1-N MTZ1-H MTZ1-L1 MTZ1 - L MTZ1 - LF MTZ2 - N MTZ2 - H MTZ2 - L MTZ2 - LF MTZ2 - H MTZ2 - L MTZ3 - H MTZ3 - L
Number of Poles [1] 3, 4 3 3 3 — 3, 4 3, 4 — — 3, 4 — 3, 4 —
Current Range, A [1] 160-1600 160-1600 160-1600 160-1600 — 160-2000 160-2000 — — 480-3000 — 800-6000 —
Number of Poles [2] 3, 4 3 3 3 3 3, 4 3, 4 3 3 3, 4 3 3, 4 3
Current Range, A [2] 160-1200 160-1200 160-1200 160-1200 160-1200 160-2000 160-2000 160-2000 160-2000 480-3000 480-3000 800-6000 800-6000
CIRCUIT BREAKERS

Interrupting Ratings
240 Vac 50 65 100 200 200 65 100 200 200 100 200 100 200
UL/CSA/NOM
480Y/277 Vac 50 50 65 100 100 65 100 150 150 100 150 100 150
Rating
480 Vac 50 50 65 100 100 65 100 150 150 100 150 100 150
(kA RMS)
600Y/347 Vac 35 50 — — — 50 85 100 100 85 100 85 100
(50/60Hz)
600 Vac 35 50 — — — 50 85 100 100 85 100 85 100
250 Vdc — — — — — — — — — — — — —
DC Ratings
500 Vdc — — — — — — — — — — — — —
IECb 240 Vac — — — — — — — — — — — — —
(kA RMS) Icu/Ics 415 Vac — — — — — — — — — — — — —
DE3

Connections/Terminations
Unit Mount X X X X X X X X X X X X X
I-Line™ — — — — — — — — — — — — —
Rear Connection X X X X X X X X X X X X X
Drawout X X X X X X X X X X X X X
Optional Lugs — — — — — — — — — — — — —
Accessories and Modifications
Digital Modules X X X X X X X X X X X X X
Shunt close (comm and diag) X X X X X X X X X X X X X
Shunt Close X X X X X X X X X X X X X
Shunt Trip (comm and diag) X X X X X X X X X X X X X
Shunt Trip X X X X X X X X X X X X X
Undervoltage Trip (diag) X X X X X X X X X X X X X
Undervoltage Trip X X X X X X X X X X X X X
Auxiliary Switches X X X X X X X X X X X X X
Alarm Switch X X X X X X X X X X X X X
Motor Operator X X X X X X X X X X X X X
Handle Operators — — — — — — — — — — — — —
Mechanical Interlocks X X X X X X X X X X X X X
Padlock Attachment X X X X X X X X X X X X X
Cylinder Lock — — — — — — — — — — — — —
Optional GF Protection X X X X X X X X X X X X X
Trip System Type
Thermal-magnetic — — — — — — — — — — — — —
Instantaneous-only (MCP) — — — — — — — — — — — — —
Molded Case Switch (Automatic) X X X X X X X X X X X X X
Electronic X X X X X X X X X X X X X
Dimensions
Height 12.67 (322) 17.28 (439) 17.28 (439) 17.28 (439)
Dimensions
(3P Unit Mount) Width 11.25 (286) 17.74 (450) 17.74 (450) 30.94 (786)
in. (mm)
Depth 13.00 (331) 18.38 (467) 18.38 (467) 18.38 (467)

Pages Catalogue 0614CT1701 Catalogue 0614CT1701

Note: All circuit breakers on this chart are UL Listed and CSA Certified unless otherwise noted.
a Tested to show arc flash hazard risk category as reference by NFPA70E
[1] Fixed version
[2] Drawout version
b Refer to Catalogue 0614CT1701 for additional ratings and other information

08/21
DE3-8
Selection Information
Insulated Case Circuit Breakers

Masterpact 1200 A NT Masterpact 3000 A NW-W Masterpact 6000A NW-Y

Circuit Breaker Type NT-N NT-H NT-L1 NT-L NT-LFa NW-N NW-H NW-L NW-LFa NW-H NW-L NW-H NW-L
Number of Poles 3, 4 3, 4 3 3 3 3, 4 3, 4 3 3 3, 4 3 3, 4 3
Current Range 100–1200 100–1200 100–1200 100–1200 100–1200 100–2000 100–2000 100–2000 100–2000 640–3000 640–3000 1200–6000 1200–6000
Interrupting Ratings
240 Vac 50 65 100 200 200 65 100 200 200 100 200 100 200

CIRCUIT BREAKERS
UL/CSA/NOM
480Y/277 Vac 50 50 65 100 100 65 100 150 150 100 150 100 150
Rating
480 Vac 50 50 65 100 100 65 100 150 150 100 150 100 150
(kA RMS)
600Y/347 Vac 35 50 — — — 50 85 100 100 85 100 85 100
(50/60Hz)
600 Vac 35 50 — — — 50 85 100 100 85 100 85 100
250 Vdc — — — — — — — — — — — — —
DC Ratings
500 Vdc — — — — — — — — — — — — —
IECb 240 Vac — — — — — — — — — — — — —
(kA RMS) Icu/Ics 415 Vac — — — — — — — — — — — — —
Special Ratings
CCC — — — — — — — — — — — — —

DE3
Fed. Specs W-C-375B/GEN — — — — — — — — — — — — —
HACR (2P, 3P) — — — — — — — — — — — — —
Connections/Terminations
Unit Mount X X X X X X X X X X X X X
I-Line™ — — — — — — — — — — — — —
Rear Connection X X X X X X X X X X X X X
Drawout X X X X X X X X X X X X X
Optional Lugs — — — — — — — — — — — — —
Accessories and Modifications
Shunt Trip X X X X X X X X X X X X X
Undervoltage Trip X X X X X X X X X X X X X
Auxiliary Switches X X X X X X X X X X X X X
Alarm Switch X X X X X X X X X X X X X
Motor Operator X X X X X X X X X X X X X
Handle Operators — — — — — — — — — — — — —
Mechanical Interlocks X X X X X X X X X X X X X
Padlock Attachment X X X X X X X X X X X X X
Cylinder Lock — — — — — — — — — — — — —
Optional GF Protection X X X X X X X X X X X X X
Trip System Type
Thermal-magnetic — — — — — — — — — — — — —
Instantaneous-only (MCP) — — — — — — — — — — — — —
Molded Case Switch (Automatic) X X X X X X X X X X X X X
Electronic X X X X X X X X X X X X X
Enclosures
General Purpose (NEMA 1) — — — — — — — — — — — — —
Raintight (NEMA 3R) — — — — — — — — — — — — —
Dust-tight (NEMA 12) — — — — — — — — — — — — —
Watertight (NEMA 4, 4X, 5) — — — — — — — — — — — — —
Explosion Proof (NEMA 7,9) — — — — — — — — — — — — —
Dimensions Height 12.67 (322) 17.28 (439) 17.28 (439) 17.28 (439)
(3P Unit Mount) Width 11.25 (286) 17.74 (450) 17.74 (450) 30.94 (786)
in. (mm) Depth 13.00 (331) 18.38 (467) 18.38 (467) 18.38 (467)
Pages Catalogue 0613CT0001 Catalogue 0613CT0001
Note: All circuit breakers on this chartare UL Listed and CSA Certified unless otherwise noted.
a Tested to show arc flash hazard risk category as reference by NFPA70E
b See Catalog 0613CT0001 for additional ratings and other information

08/21
DE3-9
QO™ and QOU Miniature Circuit Breakers
QO™ Miniature Circuit Breakers Class 730, 731, 733 / Refer to Catalog 0730CT9801

QO™ miniature circuit breakers are plug-on products for use in QO load centers, NQOD panelboards, NQOD OEM interiors or Speed-D™
switchboard distribution panels. Bolt-on QOB circuit breakers are for use in NQOD panelboards or interiors.a
The QO exclusive Qwik-Open™ mechanism, with a trip reaction within 1/60th of a second, is standard on all 1P 15 A and 20 A QO circuit breakers.
Plug-On Circuit Breakers QO-QOB Ring Terminal (20% $ Price
1P—120/240 Vac
2P—120/240 Vac 2P—240 Vac c 3P—240 Vac Adder)—Factory Installed Only
Amperes Common Trip Common Trip Common Trip
Rating b Ampere Rating Poles Suffix
Cat. No. Cat. No. Cat. No. Cat. No.
10 k AIR 10–30 A 1, 2, 3 5237
10 A QO110 QO210 — QO310 35–60 A 1,2
5238
15 A QO115 cd QO215c QO215H QO315c 35–50 A 3
20 A QO120 cd QO220c QO220H QO320c 70–110 A 2
5273
25 A QO125c QO225c QO225H QO325c 60–100 A 3
QO 1P 30 A QO130c QO230c QO230H QO330c
1 Space Required 35 A QO135 c QO235c — QO335c Wire Sizesb
40 A QO140 c QO240c QO240H QO340c Circuit Breaker Ampere Wire Size
45 A QO145c QO245c — QO345c Type Rating (AWG/kcmil)
50 A QO150c QO250c QO250H QO350c 10–30 A 14–8 Al/Cu
60 A QO160c QO260c QO260H QO360c QO 10–30 A (2) 14–10 Cu
1P
70 A QO170c QO270c QO270H QO370c 35–70 A 8–2 Al/Cu
CIRCUIT BREAKERS

80 A — QO280c QO280H QO380c 10–30 A 14–8 Al/Cu


90 A — QO290c QO290H QO390c 10–30 A (2) 14–10 Cu
100 A — QO2100c QO2100H QO3100c QO 35–70 A 8–2 Al/Cu
2P
QOT 1P Tandem 110 A — QO2110c — — 80–125 A 4–2/0 Al/Cu
1 Space Required 125 A — QO2125c — — 150–200 A 4–300 Al/Cu
150 A — QO2150cej — — 10–30 A 14–8 Al/Cu, (2) 14-10 Cu
175 A — QO2175cej — — QO 35–70 A 8–2 Al/Cu
3P
200 A — QO2200cej — — 80–125 A 4–2/0 Al/Cu
Molded Case Switch 60 A max.–240 Vac — QO200 QO300 QOB-VH 110–150 A 4–300 Al/Cu
Molded Case Switch 100 A max.–240 Vac — QO2000h QO3000h QOT 15–20 A 12–8 Al 14–8 Cu
DE3

22 k AIRc QO-AFI, QO-GFI 15–30 A 12–8 Al 14–8 Cu


15 A QO115VHd QO215VHf — QO315VHf & QO-EPD 40, 50, 60 A 12–4 Al 14–6 Cu
20 A QO120VHd QO220VHf — QO320VHf QO-PL 10–60 A 12–2 Al 14–2 Cu
25 A QO125VH QO225VHf — QO325VHf
30 A QO130VH QO230VH f — QO330VHf
QO 2P
40 A — QO240VHf — QO340VHf
2 Spaces Required
50 A — QO250VHf — QO350VHf
60 A — QO260VHf — QO360VHf
70 A — QO270VHf — QO370VHf
80 A — QO280VHf — QO380VH f
90 A — QO290VHf — QO390VHf
100 A — QO2100VHfg — QO3100VH f
110 A — QO2110VHfg — —
125 A — QO2125VHfg — —
150 A — QO2150VHefj — —
175 A — QO2175VHefj — —
200 A — QO2200VHefj — —
QO2200 2P 200 A 42 k AIRc Replacement Tandem Circuit Breakers
4 Spaces Required 40 A — QOH240h — — For Use in Old Style Non-Class CTL
45 A — QOH245h — — QO Load Centers—10 k AIR
50 A — QOH250h — — Ampere Ratingb Cat. No.c $ Price
60 A — QOH260h — — 1P—120/240 Vac—1 Space Required
70 A — QOH270 — — 15 &A 15 A QO1515
80 A — QOH280 — — 15 A & 20 A QO1520
90 A — QOH290 — — 20 A & 20 A QO2020
100 A — QOH2100 — — 20 A & 30 A QO2030
110 A — QOH2110h — — 30 A & 20 A QO3020
125 A — QOH2125 — — Two 1P Individual Trip—120/240 Vac—2 Spaces Required
65 k AIRc 15 A & 15 A Order Two QO1515 or QO2020 circuit
breakers and handle tie QOTHT for
QO 3P 15 A QH115d QH215 — QH315c 15 A & 20 A common switching of center two poles.
3 Spaces Required 20 A QH120d QH220 — QH320 20 A & 20 A — —
25 A QH125h QH225h — QH325h 20 A & 30 A QO20303020i
30 A QH130 QH230 — QH330 30 A & 20 A — —
a See Section 1 for load centers, and Section 5 for panelboards and interiors.
b 10–30 A circuit breakers are suitable for use with 60oC or 75oC conductors. 35–125 A circuit breakers
are suitable for use with 75oC con Delta systems.
c CSA/UL Listed as HACR type for use with air conditioning, heating and refrigeration equipment having
motor group combinations and marked for use with HACR type circuit breakers.
d CSA/UL Listed as SWD (switching duty) rated. Suitable for switching 120 Vac fluorescent lighting
loads.
e Requires four spaces (1 AWG–300 kcmil Al/Cu.) Suitable for switching 120 Vac fluorescent lighting
loads.
f CSA/UL Listed for use ahead of QO, QO-GFI, QO-EPD, QO-AFI, QOT,QOCAFI, and QO-PL 10 k AIR
circuit breakers to permit their application at 22 kA fault level.
g 100 A maximum branch mounted opposite.
h Order only. Contact your local Field Office.
i Includes two circuit breakers (one QO2030 and one QO3020) and handle tie QOTHT.
j Not suitable for use in 3Ø panels. Use only in 1Ø panel rated 150 A or greater.
Interrupting Ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page DE3-2
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page DE3-12
Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page DE3-44

11/18
08/21
DE3-10
QO™ and QOU Miniature Circuit Breakers
Class 685, 690, 730, 912, 950 / Refer to Catalog 0730CT9801 QO™ Miniature Circuit Breakers

QO™ Arc-Fault Circuit Breaker QO-HID


QO-CAFI HID circuit breakers are for use on circuits feeding
fluorescent and high intensity discharge (HID) lighting
1P systems such as mercury vapor, metal halide, or high
QO-CAFI QO Combination Arc Fault Circuit Breakersa pressure sodium. These circuit breakers are physically
interchangeable with QO circuit breakers.
1P 120 Vac 1P 120 Vac

Circuit Breaker Type


Ampere 10 k AIR 22 k AIR QO-HID Circuit Breakers
Rating 1 Space Required 1 Space Required
1P 120/240 Vac 2P Common Trip 3P Common Trip
Cat. No. Cat. No. 120/240 Vac 240 Vac
15 A QO115CAFI QO115VHCAFI Ampere 10 k AIR 10 k AIR 10 k AIR
Combination Arc-fault
Ratingc
Interrupter 20 A QO120CAFI QO120VHCAFI 1 Space Required 2 Spaces Required 3 Spaces Required

1P 2P QO Dual Function Circuit Breaker Cat. No. $ Price Cat. No. $ Price Cat. No. $ Price
QO-GFI QO-GFI Ampere 1P 120 Vac 10k AIR 1P 120 Vac 22k AIR 15 A QO115HIDb QO215HID QO315HID
Circuit Breaker Type Rating 1 Space Required 1 Space Required 20 A QO120HIDb QO220HID QO320HID
QO Dual Function 15 QO115DF QO115VHDF 25 A QO125HID QO225HID QO325HID
Circuit Breaker 30 A QO130HID QO230HID QO330HID
with Pigtail Neutral 20 QO120DF QO120VHDF
40 A QO140HID QO240HID —
QO Plug-on Neutral 15 QO115PDF QO115VHPDF 50 A QO150HID QO250HID —
Dual Function
20 QO120PDF QO120VHPDF
Circuit Breaker QO-K

CIRCUIT BREAKERS
QO-GFI Circuit Breakers Key operated QO circuit breakers are available in single-
3P Qwik-Gard Circuit Breakers pole construction and can be mounted in any single-pole
Ampere Ratingc (A)

QO-GFI With Ground Fault Circuit Interrupter space which will accept a standard QO. These circuit
2P Common Trip breakers can be turned ON or OFF or to RESET with a
1P 120 Vac
120/240 Vac special key (catalog number QOK10) included with the
10 k AIR 22 k AIR 10 k AIR circuit breaker. These circuit breakers are UL Listed and
1 Space Required 1 Space Required 2 Spaces Required
available as shown in the table.
Cat. No. Cat. No. Cat. No. QO-K Circuit Breakers
15 QO115GFI QO115VHGFI QO215GFI
120 Vac—10 k AIR (1 Space Required)

DE3
20 QO120GFI QO120VHGFI QO220GFI
25 QO125GFI QO125VHGFI QO225GFI Ampere Rating c Cat. No.
30 QO130GFI QO130VHGFI QO230GFI 10 A QO110K
40 — — QO240GFI 15 A QO115K
Two-wire
50 — — QO250GFI 20 A QO120K
QO-SWN
60 — — QO260GFId 30 A QO130K

QO-EPD/EPE QO-HM
QO-EPD/EPE circuit breakers provide overload and short High magnetic trip circuit breakers are recommended for
circuit protection combined with Class B ground fault applications where high initial inrush may occur and for
protection. They are designed to provide ground fault individual dimmer applications.
protection of equipment at a 30 milliampere level (EPD) or QO-HM Circuit Breakers
100 milliamp level (EPE). They are not designed to protect 1P
Three-wire people from electrical shock. Ampere Ratingc
Cat. No
QO-SWN
QO-EPD Circuit Breakers 120 Vac—10 k AIR
15 A QO115HMab
1P 2P Common Trip 3P Common Trip
Ampere Ratingc (A)

120 Vac 120/240 Vac 240 Vac 20 A QO120HMab

10 k AIR 10 k AIR 10 k AIR Non-automatic (Standard) Miniature Switches


1 Space 2 Spaces Required 3 Spaces Required Miniature non-automatic switches have the same physical
Required
packaging as miniature circuit breakers, but open only
Cat. No. Cat. No. Cat. No. Cat. No. when the handle is switched to the OFF position.
15 QO115EPD QO215EPD QO315EPDe QO315EPEe Non-automatic switches provide no overcurrent protection
20 QO120EPD QO220EPD QO320EPDe QO320EPEe or short circuit protection. They must not be used on
25 QO125EPD QO225EPD — — systems that have an available fault current greater than
30 QO130EPD QO230EPD QO330EPDe QO330EPEe the values listed in the table.
40 — QO240EPD QO340EPDe QO340EPEe
Non-automatic switches are UL Listed per UL 1087 and
QO 1P 50 — QO250EPD QO350EPDe QO350EPEe
are CSA certified.
With Shunt Trip 60 — QO260EPDd — —
QO, 240 Vac 10 kA
QO-SWN
2P 3P
Switch Neutral Common Trip 2008 NEC™ 514.11 Ampere
Rating Cat. No. Cat. No.
QO-SWN Circuit Breakers 60 A QO200 QO300
100 A QO2000 QO3000
2 Wire 120 Vac 3 Wire 120/240 Vac
a CSA/UL Listed as HACR type for use with air conditioning, heating and
Ampere 10 k AIR 10 k AIR refrigeration equipment having motor group combinations and marked
Ratingc 2 Spaces Required 3 Spaces Required for use with HACR type circuit breakers.
b CSA/UL Listed as SWD (switching duty) rated. Suitable for switching
Cat. No. Cat. No. 120 Vac fluorescent lighting loads.
10 A QO210SWN — c 10–30 A circuit breakers are suitable for use with 60° C or 75° C
15 A QO215SWN QO315SWN conductors. 35–60 A circuit breakers are suitable for use with 75° C
conductors.
20 A QO220SWN QO320SWN d Suitable only for feeding 240 Vac and 208 Vac two-wire loads. Does not
25 A QO225SWN — contain load neutral connection.
30 A QO230SWN QO330SWN e See note in Instruction Bulletin when using in an enclosure with a
40 A QO240SWN QO340SWN QO403 or QON prefix.
QO-K Key
Operated 50 A QO250SWN QO350SWN Interrupting Ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page DE3-2
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page DE3-12
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page DE3-44

11/18
DE3-11
08/21
QO™ and QOU Miniature Circuit Breakers
QO™ Circuit Breaker Accessories Class 1130 / Refer to Catalog 0730CT9801

Accessories for Use with QO™ and QOB Miniature Circuit Breakers
Handle Attachments Description Cat. No.
Converts any two adjacent 120/240 Vac 1P QO circuit breakers to independent trip 2P QO1HT
Handle Tie: Converts any two adjacent 120/240 Vac 1P side-by-side QOT circuit breakers to independent trip 2P QOTHT
Handle tie and lock-off for three 1P QO, QOB circuit breakers QO3HT
Clamp for holding QO 1P handle in ON or OFF position QO1LO
Handle Clamp:
Clamp for holding QO or Q1 1P, 2P or 3P circuit breaker handles in ON or OFF position HLO1
For padlocking 1P QO circuit breaker in ON or OFF position
Loose attachment QOHPL
Fixed attachment QO1PA
Handle Padlock Attachment: for For padlocking 1P side-by-side QOT circuit breaker in ON or OFF position QOTHPA
Padlocking in ON or OFF position For padlocking 2P and 3P QO-GFI, QO-EPD, and QO-EPE in either ON or OFF position, fixed attachment. GFI2PA
For 2P and 3P QO and Q1 standard circuit breakers which require padlocking in either ON or OFF position.
Loose attachment QO1HPL
Fixed attachment QO1PL
For padlocking 1P QO circuit breaker in OFF position only, fixed attachment. QO1PAF
Handle Padlock Attachment: for For padlocking 2P and 3P QO circuit breakers in OFF position only, fixed attachment. QO2PAF
Padlocking in OFF position For padlocking 1P QO-GFI, QO-AFI, QO-CAFI, and QO-EPD circuit breakers in OFF position only, fixed attachment. QOGFI1PAF
For padlocking 2P and 3P QO-GFI, QO-EPD, and QO-EPE circuit breakers in OFF position only, fixed attachment. QOGFI2PAF
Sub-Feed Lugs 60 A 2P plug-on – 2 spaces required (6–2 Al/Cu) QO60SL
CIRCUIT BREAKERS

125 A 2P plug-on – 2 spaces required (12–2/0 Al/Cu) QO2125SL


225 A 2P plug-on – 4 spaces required (4–300 Al/Cu) QO2225SLa
125 A 3P plug-on – 3 spaces required (12–2/0 Al/Cu) QO3125SL
Mechanical Interlock Attachment For interlocking the handles of two 2P or one 2P and one 1P QO and Q1 circuit breakers mounted side-by-side so that only one circuit
breaker can be ON at a time (Not QOU) QO2DTI
QO2DTI mechanical interlock attachment with retaining kits for securing two adjacent back-fed circuit breakers in dual power supply
With Retaining Kit: applications. Can be used with (2) 2Ps or (1) 2P and (1) 1P QO circuit breakers in QO816L100 load centers. QO2DTIM
a Not suitable for use in 3Ø panels. Use only in 1Ø panel rated 150 A or greater.

QO1PL
DE3

QO1PA QO1HT QO1LO QO1PAF

HLO1

QO2DTI
QO1HPL QO2PAF QOGFI2PAF
QOTHPA
QOHPL

Factory-Installed Accessories for Use with QO and QOB Miniature Circuit Breakers
Factory-installed electrical accessories take up an additional pole space on QO™, QO-GFI, QO-EPD, QO-SWN and
QOU circuit breakers. All AC electrical accessories shown below are rated for 50/60 Hz. Accessories are not available
for QOB-VH (2P 150 A and 3P 110–150 A) circuit breakers or QO, QOU molded case switches. QO circuit breakers will
accept only one accessory per circuit breaker. Undervoltage trip is not available on miniature circuit breakers. Factory-
installed accessories are not available for QO-AFI or QO-CAFI Arc Fault Circuit Breakers or on QO2150, QO2175, or
QO2200 circuit breakers.
Factory-Installed Accessories
Rated Coil Cat. No. Contact Max. Max. Cat. No.
Accessory Description Voltage Burden Suffix Accessory Description Comb. Voltage Load Suffix
12 60 VA
AC/DC -1042 Monitors circuit breaker contact status and
Trips the circuit breaker from a remote 24 168 VA provides a remote signal indicating the circuit
location by means of a trip coil 120 72 VA breaker contacts are OPEN or CLOSED.
energized from a separate circuit. A Auxiliary 1A AC 120 5A -1200
120 Vac shunt trip will operate at 55% AC 208 228 VA -1021 Switches 1B AC 120 5A -1201
Application
or more of rated voltage. All other shunt 240 288 VA
trips will operate at 75% or more of • Auxiliary switch terminals accept
rated voltage. (2) 14–12 AWG Cu leads.
Shunt Trip Application
• For use with momentary or Used with control circuits and is actuated only
when the circuit breaker has tripped. Standard
maintained push button. construction includes a normally-open contact.
• Not available on QO-GFI, QO-
Alarm Switches 1A AC 120 5A -2100
EPD, QO-AFI, QOCAFI. Application
• Shunt trip terminals accept • Alarm switch terminals accept
(2) 14–12 AWG Cu.
(2) 14–12 AWG Cu leads.

11/18
08/21
DE3-12
QO™ and QOU Miniature Circuit Breakers
Class 652 / Catalogs 0730CT9801, 0860CT0201 QO™ and Multi 9™ Mounting Bases
QO OEM Mounting Bases
Main Lug 1P Max. No. Mounting Bases Main Wire Size
Voltage System Rating Spaces 1P AWG/kcmil
Cat. No.
QO Plug-On Mounting Bases—For unit mounting QO, QO-GFI, QO-AFI and QO-EPD circuit breakers
1Ø2W 240 Vac Max. 10 k AIC 70 A 2 2 QON2L70 14–4 Cu, 12–3 Al
40 A 2 2 QON2L40 14–6 Cu, 12–6 Al
70 A 2 4 QON24L70 14–4 Cu, 12–3 Al
100 A 6 12 QON612L100 8–1/0 Cu/Al
100 A 8 16 QON816L100 8–1/0 Cu/Al
125 A 12 12 QON112L125I 4–2/0 Cu/Al
1Ø3W 240 Vac Max. 10 k AIC 125 A 16 16 QON116L125I 4–2/0 Cu/Al
125 A 20 20 QON120L125I 4–2/0 Cu/Al
SN12125 125 A 32 32 QON132L125I 4–2/0 Cu/Al
200 A 12 12 QON124L200I 4–250 Cu/Al
200 A 12 12 QON12L200FTLb 4–250 Cu/Al
225 A 42 42 QON142L225I 4–300 Cu/Al
125 A 12 12 QON312L125 4–2/0 Cu/Al
3Ø3W 240 Vac Max. 10 k AIC 200 A 18 18 QON318L200 4–300 Cu/Al
(Without Neutral Assy.) 200 A 24 24 QON324L200 4–300 Cu/Al
200 A 30 30 QON330L200 4–300 Cu/Al
60 A 3 3 QON403L60N 12–6 Cu/Al
3Ø4W 240 Vac Max.
10 k AIC 125 A 24 24 QON324L125I 4–2/0 Cu/Al
200 A 24 24 QON324L200I 4–300 Cu/Al
QO Plug-On Mounting Bases—For unit mounting QO, QO-GFI and QO-EPD circuit breakers

CIRCUIT BREAKERS
70 A 1 1 QOMB1 14–4 Cu 12–2 Al
QON2L40 1Ø2W 240 Vac Max. 10 k AIC 70 A 2 2 QOMB2 14–4 Cu 12–2 Al
(Without Neutral Assembly) 70 A 3 3 QOMB3 14–4 Cu 12–2 Al
QOB Bolt-On Mounting Bases—For unit mounting QOB, QOB-GFI, QOB-EPD circuit breakers
3Ø3W 240 Vac Max.10 k AIC
(Without Neutral Assembly) 100 A 3 3 QON3Bc 12–1 Cu/Al
b Device comes with factory-installed feed-thru lugs.
c UL listed only.

DE3
QON120L125I

Solid Neutral Assemblies


Main Lug Number of Branch Main Neutral Lug Wire Size Branch Neutral Terminal Wire Size
Rating Neutral Terminals Cat. No. $ Price
Cu/Al Cu Al
125 A 20 SN20 4–2/0 AWG 14–4 AWG 12–4 AWG
200 A 12 SN1200 4 AWG–300 kcmil 14–4 AWG 12–4 AWG
200 A 30 SN30 4 AWG–300 kcmil 14–4 AWG 12–4 AWG

Multi-9 Mounting Bases for CSA C22.2 No. 5/UL489 C60, 240 Vac max.
Length
Description Poles Amperes Cat. No.
in. mm
12 10.4 264 US11220018
– – – –
One-conductor 200 A
Mounting Base 36 19 483 US13620018
– – – –
– – – –
12 150 A 10.4 264 US21215018
24 14.4 366 US22420018
Two-conductor
Mounting Base – – – –
200 A
48 23 584 US24820018
– – – – –
12 100 A 10.4 264 US31210018
– – – –
Three-conductor
US Mounting Base Mounting Base 36
200 A
19 483 US33620018
for CSA C22.2 No. 5/UL489 – – – –
C60 60 27.5 699 US36020018
(3 conductor shown) Accessories for US Mounting Base for CSA C22.2 No. 5/UL489 C60
Description Cat. No.

Terminal cover for US mounting base; provides IP20 ingress protection per IEC 60529; suitable for jumper bars or cable USMBTC

11/18
DE3-13
08/21
QO™ and QOU Miniature Circuit Breakers
QOU Miniature Circuit Breakers Class 720 / Refer to Catalog 0730CT9801

Low Ampere QOU Miniature Circuit Breakers


QOU unit mount miniature circuit breakers (cable-in/cable-out) are ideal for OEM applications. They have the Square D™
circuit breaker’s unique Visi-Trip™ feature and can be DIN rail-mounted or surface- or flush-mounted using mounting feet.

General Specifications Common to All Low Ampere QOU Circuit Breakers


• For convenient flush mount, surface mount or DIN mount • CSA/UL Listed 48 Vdc (5 k AIR)
Low Ampere QOU (symmetrical rail 35 x 7.5 DIN/EN 50 022) • CSA/UL Listed as HACR Type: 10–70 A
• Single handle with internal common trip • High magnetic trip circuit breakers (QOU-HM) are recommended
• Terminal lug wire size (1) 14–2 AWG Cu or Al for applications where high initial inrush may occur and for
• Reversible line and load lugs individual dimmer applications.
• Field-installable quick connectors

QOU Low Ampere Miniature Circuit Breakers


Ampere 1P 120/240 Vac 2P 120/240 Vac 2P 240 Vac 3P 240 Vac
Rating Cat. No. Cat. No. Cat. No.a $ Price Cat. No.
10 k AIR
10 A QOU110 QOU210 — QOU310
15 A QOU115 QOU215 QOU215H QOU315
CIRCUIT BREAKERS

20 A QOU120 QOU220 QOU220H QOU320


25 A QOU125 QOU225 — QOU325
30 A QOU130 QOU230 QOU230H QOU330
35 A QOU135 QOU235 — QOU335
40 A QOU140 QOU240 — QOU340
45 A — QOU245 — QOU345
50 A QOU150 QOU250 — QOU350
60 A QOU160 QOU260 — QOU360
70 A QOU170 QOU270 — QOU370
22 k AIR
DE3

15 A QOU115VH QOU215VH — —
20 A QOU120VH QOU220VH — QOU320VH
25 A QOU125VH — — —
30 A QOU130VH QOU230VH — QOU330VH
35 A — — — —
40 A QOU140VH — — —
45 A — — — —
50 A QOU150VH QOU250VH — —
60 A QOU160VH QOU260VH — —
a QOU-H interrupting rating is 10 kA at 240 Vac.

QOU-HM Miniature Circuit Breakers (10 k AIR)


Ampere 1P 120/240 Vac 2P 120/240 Vac 2P 240 Vac 3P 240 Vac
Rating Cat. No. Cat. No. Cat. No. Cat. No.
15 A QOU115HM — — —
20 A QOU120HM — — —

High Ampere QOU High Ampere QOU Circuit Breakers


General Specifications Common to All High Ampere QOU Circuit Breakers
• Flush mount, surface mount, and DIN rail mount. • CSA/UL Listed as HACR type, 80–125 A.
• Internal common trip. • Non-automatic switches have the same physical packaging
• Non-reversible line and load lugs. as miniature circuit breakers, but provide no overcurrent or
• Terminal lug wire size (1) 12– 2/0 AWG Cu or Al. short circuit protection. They are UL Listed per UL1087 and
• UL Listed 60 Vdc per pole (5 k AIR). (Note: except switches) are CSA certified.

QOU High Ampere Miniature Circuit Breakers (10 k AIR)


Ampere 1P 120/240 Vac 2P 120/240 Vac 2P 240 Vac 3P 240 Vac
Rating Cat. No. Cat. No. Cat. No. Cat. No.
80 A QOU180 QOU280 — QOU380
90 A — QOU290 — QOU390
100 A QOU1100 QOU2100 — QOU3100
125 A — QOU2125 — —

QOU Non-Automatic Switches


Ampere 1P 120 Vac 2P 120/240 Vac 2P 240 Vac 3P 240 Vac
Rating Cat. No. Cat. No. Cat. No. Cat. No.
60 A — — QOU200 QOU300
100 A — — — QOU3000
125 A — — — —

Interrupting Ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page DE3-3


Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page DE3-12, DE3-15
Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page DE3-44

08/21
DE3-14
QO™ and QOU Miniature Circuit Breakers
Class 720 / Refer to Catalog 0730CT9801 QOU Accessories
Accessories for QOU Low Ampere Circuit Breakers (Except as Noted)
Order
Description Qty. Cat. No.

Factory-installed ring tongue terminal, 10–32 screw, for 1P, 2P, 3P QOU, 10–60 A — Suffix -5283
Hex drive 5/32 in. wire binding screw for QOU — Suffix -5280
For padlocking 1P low ampere QOU circuit breaker in OFF or ON position — QOU1PA
4P Jumper Bar For padlocking 2P and 3P low ampere QOU circuit breaker in OFF or ON position — QOU1PL
Assembly Base For padlocking 1P low ampere QOU circuit breaker in OFF position only — QOU1PAFLA
For padlocking 2P and 3P low ampere QOU circuit breaker in OFF position only — QOU2PAFLA
For padlocking 2P and 3P high ampere QOU circuit breaker in OFF position only — Suffix -7100
Handle lock-out, ON or OFF position — HLO1
Cover and Cover Screw 4P 100 A Jumper bar assy. w/front wiring with base, cover and screw 1 QOU14100JBAF
4P 100 A Jumper bar assy. w/left side wiring with base, cover and screw 1 QOU14100JBAL
1Ø, 4P, 100 A Jumper bar base with front wiring 40 QOU14100BAFB
1Ø, 4P, 100 A Jumper bar base with left side wiring 40 QOU14100BALB
QOU14100JBAF
1Ø, 4P, 100 A Jumper bar base with right side wiring 40 QOU14100BARB
4P Jumper bar cover 40 QOU14100CAB
Mounting screw for jumper bar cover 40 QOU1CMSB
6P 150 A Jumper bar assy. w/front wiring with base, cover and screw 1 QOU16150JBAF
1Ø, 6P, 150 A Jumper bar base with front wiring 40 QOU16150BAFB

CIRCUIT BREAKERS
1Ø, 6P, 150 A Jumper bar base with left side wiring 40 QOU16150BALB
6P jumper bar cover 40 QOU16150CAB
1 BCVa
Vertical rainproof cover 2P and 3P QO, QOU, FA and KA
10 BCVBa
QOURT
Field-installable 1 BCHa
Horizontal rainproof cover 2P QO, QOU, and 3P Q2, EH 10 BCHBa
Ring Tongue Terminal
Connector 1 QOUHFSC1
1P Fingersafe™ cover for high ampere QOU circuit breaker
40 QOUHFSC1B
Crimp connectors are 1P Fingersafe cover for low ampere QOU circuit breaker 1 QOULFSC1
not included with 40 QOULFSC1B

DE3
Square D brand connectors
QOUEC Field- 1 QOURT
installable Field-installable ring tongue terminal adaptor 80 QOURTB
Quick Connector
1 QOUEC
Quick connector end connection wiring
2P DIN Mounted QOU Circuit Breakers 40 QOUECB

1P QOU mounting foot 1 QOUMF1a


80 QOUMF1Ba
2P QOU mounting foot 1 QOUMF2a
40 QOUMF2Ba

Tapped mounting foot for QOU, 1P and 2P 10–70 A, 3P 10–60 A


Packaged with circuit breaker Suffix -3100
Mounting Foot Individually packaged 1 QOUMFS1
QOUMF1
Mechanical interlock attachment: Used to interlock two circuit breakers mounted
side-by-side so that only one circuit breaker can be ON at a time. A 1P or 2P circuit breaker can 1 QOU2DTILA b
be mounted on the left and interlocked with a 2P or 3P circuit breaker on the right.
a For use on low and high ampere QOU.
b 10–70 A 1P and 2P, 10–60 A 3P.

For QOUQ Low Ampere Circuit Breakers with Four-Point Quick-Connect


Terminals
Tapped Mounting Foot
Suffix–3100 QOUQ low ampere circuit breakers with four-point quick-connect terminals are provided
with permanent factory-installed terminals which are affixed to the Load or OFF end of the
circuit breaker. This special terminal will accommodate up to four 1/4-inch insulated female
quick connect wire terminations. Total ampacity of these connections must not exceed the
rating of the circuit breaker.

QOUQ Four-Point Quick-Connect Terminals


Poles Order Qty. Cat. No.
1 1
Four-Point Quick-Connect Terminals 2 1 Change QOU to
QOUQ
3 1

Electrical Accessories for QOU . . . . . . . . . . . . . . . . . . . . . . . . . Page DE3-12

08/21
DE3-15
Multi 9™ Miniature Circuit Breakers
CSA C22.2 No. 5/UL 489 C60BP/BPR Miniature Circuit Breakers Refer to Catalog LVCATM9OEM

UL 489 / CSA C22.2 No 5 / IEC/EN 60947-2 / GB 14048-2


C60BP/BPR are multi-standard miniature circuit breakers and branch circuit protection as defined
by UL 489. It combines following functions:
• circuit protection against short-circuit currents
• circuit protection against overload currents
• tripping and fault indication by the addition of auxiliaries
• IP2X ring tongue terminal connection.
Conformity with product standards
• UL 489 branch circuit protection, document #E215117.
• CSA C22.2 No 5 branch circuit protection, document #E179014.
• IEC/EN 60947-2.
• GB 14048-2.

Catalogue numbers
Tunnel terminal connection
UL489 and 1P 2P 3P
Type CSA
voltages
Curve Curve Curve
Rating (In)
CIRCUIT BREAKERS

Z C D (=K) C D (=K) C D (=K)


C60BP
0.5 M9F44170 M9F42170 M9F43170 - - - -
1 M9F44101 M9F42101 M9F43101 M9F42201 M9F43201 M9F42301 M9F43301
2 M9F44102 M9F42102 M9F43102 M9F42202 M9F43202 M9F42302 M9F43302
3 M9F44103 M9F42103 M9F43103 M9F42203 M9F43203 M9F43203 M9F43303
4 M9F44104 M9F42104 M9F43104 M9F42204 M9F43204 M9F42304 M9F43304
480Y/277 V and 240 V

5 M9F44105 M9F42105 M9F43105 M9F42205 M9F43205 M9F43205 M9F43305


6 M9F44106 M9F42106 M9F43106 M9F42206 M9F43206 M9F42306 M9F43306
C60BP 1P
DE3

8 M9F44108 M9F42108 M9F43108 M9F42208 M9F43208 M9F42308 M9F43308


10 M9F44110 M9F42110 M9F43110 M9F42210 M9F43210 M9F42310 M9F43310
15 M9F44115 M9F42115 M9F43115 M9F42215 M9F43215 M9F42315 M9F43315
20 M9F44120 M9F42120 M9F43120 M9F42220 M9F43220 M9F42320 M9F43320
25 M9F44125 M9F42125 M9F43125 M9F42225 M9F43225 M9F42325 M9F43325
30 M9F44130 M9F42130 M9F43130 M9F42230 M9F43230 M9F42330 M9F43330
35 M9F44135 M9F42135 M9F43135 M9F42235 M9F43235 M9F42335 M9F43335
40 M9F44140 M9F42140 M9F43140 M9F42240 M9F43240 M9F42340 M9F43340
240 V only

45 M9F44145 M9F42145 - M9F42245 - M9F42345 -


50 M9F44150 M9F42150 - M9F42250 - M9F42350 -
63 M9F44163 M9F42163 - M9F42263 - M9F42363 -
Ring tongue terminal connection
UL489 and 1P 2P 3P
Type CSA
voltages
Curve Curve Curve
C60BP 2P Rating (In)
Z C D (=K) C D (=K) C D (=K)
C60BPR
1 M9F54101 M9F52101 M9F53101 M9F52201 M9F53201 M9F52301 M9F53301
2 M9F54102 M9F52102 M9F53102 M9F52202 M9F53202 M9F52302 M9F53302
4 M9F54104 M9F52104 M9F53104 M9F52204 M9F53204 M9F52304 M9F53304
480Y/277 V and 240 V

6 M9F54106 M9F52106 M9F53106 M9F52206 M9F53206 M9F52306 M9F53306


8 M9F54108 M9F52108 M9F53108 M9F52208 M9F53208 M9F52308 M9F53308
10 M9F54110 M9F52110 M9F53110 M9F52210 M9F53210 M9F52310 M9F53310
15 M9F54115 M9F52115 M9F53115 M9F52215 M9F53215 M9F52315 M9F53315
20 M9F54120 M9F52120 M9F53120 M9F52220 M9F53220 M9F52320 M9F53320
25 M9F54125 M9F52125 M9F53125 M9F52225 M9F53225 M9F52325 M9F53325
30 M9F54130 M9F52130 M9F53130 M9F52230 M9F53230 M9F52330 M9F53330
35 M9F54135 M9F52135 M9F53135 M9F52235 M9F53235 M9F52335 M9F53335
40 M9F54140 M9F52140 M9F53140 M9F52240 M9F53240 M9F52340 M9F53340
240 V only

45 M9F54145 M9F52145 - M9F52245 - M9F52345 -


50 M9F54150 M9F52150 - M9F52250 - M9F52350 -
63 M9F54163 M9F52163 - M9F52263 - M9F52363 -
C60BP 3P Interrupting ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Page DE3-3
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Page DE3-18
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Page DE3-44
Mounting Bases . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Page DE3-13

08/21
DE3-16
Multi 9™ Miniature Circuit Breakers
Refer to Catalog LVCATM9OEM CSA C22.2 No. 235/UL 1077 C60SP Supplementary Protectors
UL 1077 / CSA C22.2 No 235/ IEC/EN 60947-2 / GB 14048-2 Conformity with product standards
C60SP are multi-standard miniature circuit breakers and supplementary protection as • UL1077 branch circuit protection, document #E90509.
defined by UL 1077. It combines following functions: • CSA C22.2 No 5 branch circuit protection, document #E179014.
• circuit protection against short-circuit currents • IEC/EN 60947-2.
• circuit protection against overload currents • GB 14048-2.
• tripping and fault indication by the addition of auxiliaries.

Catalogue numbers
Tunnel terminal connection
Type 1P 2P
Curve Curve
Rating (In)
B C D (=K) B C D (=K)
C60SP
0.5 M9F21170 M9F22170 M9F23170 - - -
1 M9F21101 M9F22101 M9F23101 M9F21201 M9F22201 M9F23201
2 M9F21102 M9F22102 M9F23102 M9F21202 M9F22202 M9F23202
3 M9F21103 M9F22103 M9F23103 M9F21203 M9F22203 M9F23203

CIRCUIT BREAKERS
4 M9F21104 M9F22104 M9F23104 M9F21204 M9F22204 M9F23204
C60SP 1P
5 M9F21105 M9F22105 M9F23105 M9F21205 M9F22205 M9F23205
6 M9F21106 M9F22106 M9F23106 M9F21206 M9F22206 M9F23206
8 M9F21108 M9F22108 M9F23108 M9F21208 M9F22208 M9F23208
10 M9F21110 M9F22110 M9F23110 M9F21210 M9F22210 M9F23210
13 M9F21113 M9F22113 M9F23113 M9F21213 M9F22213 M9F23213
16 M9F21116 M9F22116 M9F23116 M9F21216 M9F22216 M9F23216
20 M9F21120 M9F22120 M9F23120 M9F21220 M9F22220 M9F23220
25 M9F21125 M9F22125 M9F23125 M9F21225 M9F22225 M9F23225

DE3
32 M9F21132 M9F22132 M9F23132 M9F21232 M9F22232 M9F23232
40 M9F21140 M9F22140 M9F23140 M9F21240 M9F22240 M9F23240
45 M9F21145 M9F22145 - M9F21245 M9F22245 -
50 M9F21150 M9F22150 - M9F21250 M9F22250 -
63 M9F21163 M9F22163 - M9F21263 M9F22263 -
C60SP 2P
Type 3P 4P
Curve Curve
Ratings (In)
Z C D (=K) C D (=K)

C60SP
0.5 - - - - - -
1 - - - - - -
2 M9F21302 M9F22302 M9F23302 M9F21402 M9F22402 M9F23402
3 - - - - - -
4 - - - - - -
5 - - - - - -
6 M9F21306 M9F22306 M9F23306 M9F21406 M9F22406 M9F23406
8 M9F21308 M9F22308 M9F23308 M9F21408 M9F22408 M9F23408
C60SP 3P
10 M9F21310 M9F22310 M9F23310 M9F21410 M9F22410 M9F23410
13 M9F21313 M9F22313 M9F23313 M9F21413 M9F22413 M9F23413
16 M9F21316 M9F22316 M9F23316 M9F21416 M9F22416 M9F23416
20 M9F21320 M9F22320 M9F23320 M9F21420 M9F22420 M9F23420
25 M9F21325 M9F22325 M9F23325 M9F21425 M9F22425 M9F23425
32 M9F21332 M9F22332 M9F23332 M9F21432 M9F22432 M9F23432
40 M9F21340 M9F22340 M9F23340 M9F21440 M9F22440 M9F23440
45 M9F21345 M9F22345 - M9F21445 M9F22445 -
50 M9F21350 M9F22350 - M9F21450 M9F22450 -
63 M9F21363 M9F22363 - M9F21463 M9F22463 -

Interrupting Ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Page DE3-3


Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Page DE3-18
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Page DE3-44
C60SP 4P

08/21
DE3-17
Multi 9™ Miniature Circuit Breakers
C60 Accessories Refer to Catalog LVCATM9OEM

Electrical Accessories for C60 Circuit Breakers and Supplementary Protectors

Possible Combinations

Mounted to the left of the circuit breaker with a maximum width of 54 mm.

+ + + +
Spacer
Ring Tongue
Terminal Kit

Max. 54 mm

SD OF MX MN
Shunt trip + Aux Undervoltage C60
Alarm Switch Auxiliary Switch Switch Release
CIRCUIT BREAKERS

Multi 9 C60 Electrical Accessories


C60 Padlock
Attachment Control Voltage
C60
Width in 9 mm UL/IEC
(1 per 1P,2P, 3P or 4P) Descriptions modules
Vac Vdc Cat. No.
OF Auxiliary Switch (1a1b) 240-415 24-130 1 M9A26924
SD Alarm Switch (1a1b) 240-415 24-130 1 M9A26927
12-24 12-24 2 M9A26948
MX Shunt Trip + OF Auxiliary Switch 48 48 2 M9A26947
DE3

(1a1b)
100-415 110-130 2 M9A26946
24 24 2 M9A27108
48 48 2 M9A26961
MN Undervoltage Release
120 — 2 M9A27107
Rotary Handle 220-240 — 2 M9A26960
115 — 2 M9A26959

Multi 9 C60 Mechanical Accessories


C60
Descriptions
Cat. No.
Ring Lug terminal kit for UL1077 C60SP For one pole 17400
Front Mounting Kit for C60 Spacer for DIN rail, Not UL Recognized 9 mm wide MG27062
1P, 2P, 3P, 4P Padlock Attachment (1 per for 1P, 2P, 3P or 4P) 2 per pack MG26970
(1 per circuit breaker) Padlocking Device Left Side Mount, Locks OFF onlya MGN26380
1 per pack
Padlocking Device Right Side Mount, Locks OFF onlyb MGN26381
1P MG26983
2P MG26984
Front Mounting Kit
3P MG26985
4P MG26989
Bag of two
Terminal Screw Shield (Not UL Recognized) for C60SP only 4P shields MG26981
Tooth Caps for UL Comb Bus Bar, Bag of 20 for C60SP only 60488
Rotary Handle for C60 (Non UL Recognized
Operating Subassembly MG27046
Door Interlock Handle 2P/3P/4P MG27047
Fixed Handle (Front or Lateral) MG27048
Multi-pole Front Mounting Kit
MGN26380 Locking Rail Support (20 of 9 mm modules) 14211
MGN26381 Locking Device
Device Left Side Mount Hinged Transparent Cover 14210
Right Side Mount
a Left-side mounted padlocking device cannot be used in conjunction with accessories SD, OF, MX or MN. Use right-
side mounted padlocking device when accessories are required.
b Right-side mounted padlocking device cannot be used in conjunction with VIGI module. Use left-side mounted
padlocking device when VIGI Module is required.

Multi-pole
Front Mounting Kit

08/21
DE3-18
08/21
PowerPact™ Molded Case Circuit Breakers
Class 611 PowerPact Family

The PowerPact Advantage


• Proven Performance: Industry-leading circuit breaker innovation and protection for heavy-duty commercial and industrial
applications.
• Smart: Integrated metering options provide a cost-effective solution to reduce energy consumption, optimize energy costs, and
improve energy availablility for your facilities.
• Flexible: Full range of thermal-magnetic and electronic trip molded case circuit breakers from 15 A to 3000 A, delivering the ratings,
configurations, and operators for your unique applications.
• Simple: Common catalog numbers, standardized ratings, and a full range of field-installable accessories make product selection,
installation and maintenance easier than ever.
• Common Design Features: Mounting holes, door trim, and handle accessories.

B-Frame H-Frame J-Frame L-Frame M-Frame P-Frame R-Frame


125 A 150 A 250 A 600 A 800 A 1200 A 3000 A

CIRCUIT BREAKERS
PowerPact Interrupting Ratings

DE3
Interrupting Rating
Voltage
B D G J K L R
240 Vac 10 kA 25 kA 65 kA 100 kA 65 kA 125 kA 200 kA
480 Vac 18 kA 35 kA 65 kA 65 kA a 100 kA 200 kA
600 Vac 14 kA 18 kA 25 kA 65 kA a 50 kAb 100 kA
a P-frame K interrupting is 50 kA at 480 and 600 Vac.
b P-frame L interrupting is 25 kA at 600 Vac.
c B-Frame K interrupting rating is 100kA at 240 Vac

Common Catalog Numbering System


Termination

Amperage
Voltage
Rating
Frame

Suffix

Suffix
Poles

Code

Code
d

H G L 3 6 1 5 0 A B S A
110 Vac Shunt Trip
2A/2B Auxiliary Switch

Frame Designation Interrupting Rating Terminations


240 Vac 480 Vac 600Vac A I-Line
B 125 A Frame
H 150 A Frame B 10 kA L Lugs on Both Ends
J 250 A Frame D 25 kA 18 kA 14 kA F Bus Bar (No Lugs)
Q 250 A Frame G 65 kA 35 kA 18 kA M Lugs Line Side Only
L 600 A Frame J 100 kA 65 kA 25 kA P Lugs Load End Only
M 800 A Frame K 65 kA 65 kA 65 kA N Plug-in
P 1200 A Frame L 125 kA 100 kA 50 kA D Drawout
R 3000 A Frame R 200 kA 200 kA 100 kA S Rear Connected Studs
d For amperage of M-, P- or R-frame circuit breakers, add a zero to the three amperage digits; for example, 120 = 1200 A.

Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page
B-Frame Circuit Breakers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . DE3-20
H- and J-Frame Circuit Breakers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . DE3-21
H- and J-Frame Circuit Breakers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . DE3-22
L-Frame Circuit Breakers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . DE3-25
P-Frame Circuit Breakers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . DE3-27
R-Frame Circuit Breakers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . DE3-28
PowerPact™ H- and J-Frame Electronic Motor Circuit Protectors . . . DE3-29
Motor Circuit Protectors and Motor Protector Circuit Breakers. . . . . . DE3-30
Automatic Switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . DE3-31
500 Vdc Circuit Breakers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . DE3-32
PowerPact™ Circuit Breaker Accessories. . . . . . . . . . . . . . . . . . . . . . DE3-33
Motor Operators and Rotary Handles . . . . . . . . . . . . . . . . . . . . . . . . . DE3-34
Locks, Installation Accessories, and Rear Connections . . . . . . . . . . . DE3-35
Mechanical Lugs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . DE3-36
Compression Lugs and Power Distribution Connectors (PDC) . . . . . DE3-37
Terminal Nuts, Terminal Pads, Terminal Shields and Accessories . . . DE3-38
Plug-In and Drawout Mountings. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . DE3-39
Micrologic™ Electronic Trip Units. . . . . . . . . . . . . . . . . . . . . . . . . . . . . DE3-40
Micrologic™ Trip Unit Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . DE3-42

11/18
DE3-19
08/21
PowerPact™ Molded Case Circuit Breakers
B-Frame Circuit Breakers Class 611 / Refer to Catalog 0611CT1603

PowerPact B-Frame Circuit Breakers


CIRCUIT BREAKERS

PowerPact B-Frame 125 A Thermal-Magnetic Circuit Breakers, 600Y/347 Vac with EverLink Lugs
Interupting Rating
DE3

Current D G J K
Rating
@ 40o C 2 Pole 3 Pole 4 Pole 2 Pole 3 Pole 4 Pole 2 Pole 3 Pole 4 Pole 2 Pole
1 Pole 1 Pole 1 Pole 1 Pole
347 Vac 600Y/347 600Y/347 600Y/347 347 Vac 600Y/347 600Y/347 600Y/347 347 Vac 600Y/347 600Y/347 600Y/347 347 Vac 600Y/347
Vac Vac Vac Vac Vac Vac Vac Vac Vac Vac
15 A BDL16015 BDL26015 BDL36015 BDL46015 BGL16015 BGL26015 BGL36015 BGL46015 BJL16015 BJL26015 BJL36015 BJL46015 BKL16015 BKL26015
20 A BDL16020 BDL26020 BDL36020 BDL46020 BGL16020 BGL26020 BGL36020 BGL46020 BJL16020 BJL26020 BJL36020 BJL46020 BKL16020 BKL26020
25 A BDL16025 BDL26025 BDL36025 BDL46025 BGL16025 BGL26025 BGL36025 BGL46025 BJL16025 BJL26025 BJL36025 BJL46025 BKL16025 BKL26025
30 A BDL16030 BDL26030 BDL36030 BDL46030 BGL16030 BGL26030 BGL36030 BGL46030 BJL16030 BJL26030 BJL36030 BJL46030 BKL16030 BKL26030
35 A BDL16035 BDL26035 BDL36035 BDL46035 BGL16035 BGL26035 BGL36035 BGL46035 BJL16035 BJL26035 BJL36035 BJL46035 — —
40 A BDL16040 BDL26040 BDL36040 BDL46040 BGL16040 BGL26040 BGL36040 BGL46040 BJL16040 BJL26040 BJL36040 BJL46040 — —
45 A BDL16045 BDL26045 BDL36045 BDL46045 BGL16045 BGL26045 BGL36045 BGL46045 BJL16045 BJL26045 BJL36045 BJL46045 — —
50 A BDL16050 BDL26050 BDL36050 BDL46050 BGL16050 BGL26050 BGL36050 BGL46050 BJL16050 BJL26050 BJL36050 BJL46050 — —
60 A BDL16060 BDL26060 BDL36060 BDL46060 BGL16060 BGL26060 BGL36060 BGL46060 BJL16060 BJL26060 BJL36060 BJL46060 — —
70 A BDL16070 BDL26070 BDL36070 BDL46070 BGL16070 BGL26070 BGL36070 BGL46070 BJL16070 BJL26070 BJL36070 BJL46070 — —
80 A BDL16080 BDL26080 BDL36080 BDL46080 BGL16080 BGL26080 BGL36080 BGL46080 BJL16080 BJL26080 BJL36080 BJL46080 — —
90 A BDL16090 BDL26090 BDL36090 BDL46090 BGL16090 BGL26090 BGL36090 BGL46090 BJL16090 BJL26090 BJL36090 BJL46090 — —
100 A BDL16100 BDL26100 BDL36100 BDL46100 BGL16100 BGL26100 BGL36100 BGL46100 BJL16100 BJL26100 BJL36100 BJL46100 — —
110 A BDL16110 BDL26110 BDL36110 BDL46110 BGL16110 BGL26110 BGL36110 BGL46110 BJL16110 BJL26110 BJL36110 BJL46110 — —
125 A BDL16125 BDL26125 BDL36125 BDL46125 BGL16125 BGL26125 BGL36125 BGL46125 BJL16125 BJL26125 BJL36125 BJL46125 — —

B-Frame Termination Options B-Frame Interupting Ratings


Termination Letter Interrupting Ratings
Voltage
A = I-Line (See Section DE5) D G J K
BDL36100
F = No Lugs (includes terminal nut kit on both ends) For factory-installed
240 Vac 25 Ka 65 Ka 100 Ka 100 Ka
L = Lugs both ends termination, letter in
the third block of the 480Y/277 Vac 18 Ka 35 Ka 65 Ka 65 Ka
M = Lugs ON end Terminal Nut Kit OFF end circuit breaker catalog
number. 480 Vac 18 Ka 35 Ka 65 Ka 65 Ka
P = Lugs OFF end Terminal Nut Kit ON end
600Y/347 Vac 14 Ka 18 Ka 25 Ka 65 Ka
Accessories see page DE3-33 600 Vac — — — —
Optional Lugs see page DE3-36
250*Vdc 10 Ka 20 Ka 50 Ka —
Dimensions see page DE3-45
Enclosures see page DE3-46 * 125 Vdc for 1P
Accessories see page DE3-33
Optional Lugs see page DE3-36
Dimensions see page DE3-45
Enclosures see page DE3-46

11/18
DE3-20
08/21
PowerPact™ Circuit Breakers
Class 611 / Refer to Catalog 0611CT1001 H- and J-Frame Circuit Breakers
H-frame 150 AThermal-magnetic CSA/UL Current-Limiting Circuit Breakers (600 Vac) with Factory SealedTrip Unit
Suitable for Reverse Connection ba
AC Magnetic
Current Trip Setting D Interrupting G Interrupting J Interrupting L Interrupting
Terminal
Rating @ Wire Range
40° C Catalogue Catalogue Catalogue Catalogue
Hold Trip Number Number Number Number
2-pole, 600 Vac 50/60 Hz
15 350 750 HDL26015 HGL26015 HJL26015 HLL26015
20 350 750 HDL26020 HGL26020 HJL26020 HLL26020
25 350 750 HDL26025 HGL26025 HJL26025 HLL26025
30 350 750 HDL26030 HGL26030 HJL26030 HLL26030
35 400 850 HDL26035 HGL26035 HJL26035 HLL26035
40 400 850 HDL26040 HGL26040 HJL26040 HLL26040
HD and HG 2 Pole 45 400 850 HDL26045 HGL26045 HJL26045 HLL26045
Thermal-Magnetic Trip Unit 50 400 850 HDL26050 HGL26050 HJL26050 HLL26050 AL150HD
#14–#3/0 AWG
60 800 1450 HDL26060 HGL26060 HJL26060 HLL26060 Cu or Al
70 800 1450 HDL26070 HGL26070 HJL26070 HLL26070
80 800 1450 HDL26080 HGL26080 HJL26080 HLL26080
90 800 1450 HDL26090 HGL26090 HJL26090 HLL26090
100 900 1700 HDL26100 HGL26100 HJL26100 HLL26100
110 900 1700 HDL26110 HGL26110 HJL26110 HLL26110

CIRCUIT BREAKERS
125 900 1700 HDL26125 HGL26125 HJL26125 HLL26125
150 900 1700 HDL26150 HGL26150 HJL26150 HLL26150
3-pole, 600 Vac 50/60 Hz
15 350 750 HDL36015 HGL36015 HJL36015 HLL36015
20 350 750 HDL36020 HGL36020 HJL36020 HLL36020
25 350 750 HDL36025 HGL36025 HJL36025 HLL36025
30 350 750 HDL36030 HGL36030 HJL36030 HLL36030
35 400 850 HDL36035 HGL36035 HJL36035 HLL36035
40 400 850 HDL36040 HGL36040 HJL36040 HLL36040

DE3
45 400 850 HDL36045 HGL36045 HJL36045 HLL36045
50 400 850 HDL36050 HGL36050 HJL36050 HLL36050 AL150HD
#14–#3/0 AWG
60 800 1450 HDL36060 HGL36060 HJL36060 HLL36060 Cu or Al
H-Frame 70 800 1450 HDL36070 HGL36070 HJL36070 HLL36070
Thermal-Magnetic Trip Unit 80 800 1450 HDL36080 HGL36080 HJL36080 HLL36080
90 800 1450 HDL36090 HGL36090 HJL36090 HLL36090
100 900 1700 HDL36100 HGL36100 HJL36100 HLL36100
110 900 1700 HDL36110 HGL36110 HJL36110 HLL36110
125 900 1700 HDL36125 HGL36125 HJL36125 HLL36125
150 900 1700 HDL36150 HGL36150 HJL36150 HLL36150

J-frame 250 A Thermal-magnetic (600 Vac) Factory Sealed Trip Unit Suitable for Reverse Connection ba
AC Magnetic D Interrupting G Interrupting J Interrupting L Interrupting R Interrupting
Current Trip Setting Terminal
Rating @ Wire Range
40° C Low High Catalogue Catalogue Catalogue Catalogue Catalogue
Number Number Number Number Number
2-pole, 600 Vac 50/60 Hz
150 750 1500 JDL26150 JGL26150 JJL26150 JLL26150 – AL175JD
#4–4/0 AWG
175 875 1750 JDL26175 JGL26175 JJL26175 JLL26175 – Al or Cu
200 1000 2000 JDL26200 JGL26200 JJL26200 JLL26200 – AL250JD
225 1125 2250 JDL26225 JGL26225 JJL26225 JLL26225 – #3/0–350 kcmil
250 1250 2500 JDL26250 JGL26250 JJL26250 JLL26250 – Al or Cu

3-pole, 600 Vac 50/60 Hz


150 750 1500 JDL36150 JGL36150 JJL36150 JLL36150 JRL36150 AL175JD
#4–4/0 AWG
175 875 1750 JDL36175 JGL36175 JJL36175 JLL36175 JRL36175 Al or Cu
200 1000 2000 JDL36200 JGL36200 JJL36200 JLL36200 JRL36200 AL250JD
225 1125 2250 JDL36225 JGL36225 JJL36225 JLL36225 JRL36225 #3/0–350 kcmil
250 1250 2500 JDL36250 JGL36250 JJL36250 JLL36250 JRL36250 Al or Cu

b See catalogue for circuit breakers with field interchangeable trip units.
a For 100% rated circuit breakers, add a “C” in the 9th character place (for example, HDL36015C or JDL26150C). 100% rated circuit breakers have
copper lugs and can only be used with copper wire.
Circuit breakers with J, L, and R interrupting ratings are CSA/UL certified as current limiting.

H- and J-frame Termination Options


Interrupting Ratings (kA) A-I-Line (see Section 5)
F = No Lugs (includes terminal nut kit)
Voltage D G J L R
L = Lugs both ends
240 V 25 65 100 125 200
M = Lugs “ON” end Terminal Nut Kit “Off” end
480 V 18 35 65 100 200
P = Lugs “OFF” end Terminal Nut Kit “On” end
600 V 14 18 25 50 100
N = Plug-inc
D = Drawoutc Plug-in Drawout Rear Connected I-Line®
Accessories - DE3-33 S = Rear Connected c
Dimensions - DE3-45 c For N,D, and S details see page DE3-39, DE3-35
Enclosures - DE3-46

11/18
DE3-21
08/21
PowerPact™ Circuit Breakers
H- and J-Frame Circuit Breakers Class 611 / Refer to Catalog 0611CT1001
H-Frame 150 A and J-Frame 250 A Electronic Trip CSA/UL Current-Limitinga Circuit Breakers
(600 Vac) With Factory Sealed Trip Unitb Suitable for Reverse Connection g
Electronic Trip Unit Interrupting Rating (2nd Letter of Catalog Number)
D G Ja La Ra
Sensor
Rating $ Price Terminal
Type Function Trip Unit
Catalogue Catalogue Catalogue Catalogue Catalogue
Numberc Numberc Numberc Numberc Numberc
600 Vac, 50/60 Hz, 3P
60 A HDL36060U31X HGL36060U31X HJL36060U31X HLL36060U31X HRL36060U31X
Micrologic 100 A HDL36100U31X HGL36100U31X HJL36100U31X HLL36100U31X HRL36100U31X AL150HDd
LI 3.2f 150 A HDL36150U31X HGL36150U31X HJL36150U31X HLL36150U31X HRL36150U31X
Standard
250 A JDL36250U31X JGL36250U31X JJL36250U31X JLL36250U31X JRL36250U31X AL250JDe
60 A HDL36060U33X HGL36060U33X HJL36060U33X HLL36060U33X HRL36060U33X
Micrologic 100 A HDL36100U33X HGL36100U33X HJL36100U33X HLL36100U33X HRL36100U33X AL150HDd
Standard LSI 3.2Sf 150 A HDL36150U33X HGL36150U33X HJL36150U33X HLL36150U33X HRL36150U33X
250 A JDL36250U33X JGL36250U33X JJL36250U33X JLL36250U33X JRL36250U33X AL250JDe
60 A HDL36060U43X HGL36060U43X HJL36060U43X HLL36060U43X HRL36060U43X
Micrologic 100 A HDL36100U43X HGL36100U43X HJL36100U43X HLL36100U43X HRL36100U43X AL150HDd
LSI 5.2A 150 A HDL36150U43X HGL36150U43X HJL36150U43X HLL36150U43X HRL36150U43X
Ammeter
250 A JDL36250U43X JGL36250U43X JJL36250U43X JLL36250U43X JRL36250U43X AL250JDe
60 A HDL36060U53X HGL36060U53X HJL36060U53X HLL36060U53X HRL36060U53X
Micrologic 100 A HDL36100U53X HGL36100U53X HJL36100U53X HLL36100U53X HRL36100U53X AL150HDd
LSI 5.2E 150 A HDL36150U53X HGL36150U53X HJL36150U53X HLL36150U53X HRL36150U53X
Energy
CIRCUIT BREAKERS

250 A JDL36250U53X JGL36250U53X JJL36250U53X JLL36250U53X JRL36250U53X AL250JDe


60 A HDL36060U44X HGL36060U44X HJL36060U44X HLL36060U44X HRL36060U44X
Micrologic 100 A HDL36100U44X HGL36100U44X HJL36100U44X HLL36100U44X HRL36100U44X AL150HDd
Ammeter LSIG 6.2A 150 A HDL36150U44X HGL36150U44X HJL36150U44X HLL36150U44X HRL36150U44X
250 A JDL36250U44X JGL36250U44X JJL36250U44X JLL36250U44X JRL36250U44X AL250JDe
60 A HDL36060U54X HGL36060U54X HJL36060U54X HLL36060U54X HRL36060U54X
Micrologic 100 A HDL36100U54X HGL36100U54X HJL36100U54X HLL36100U54X HRL36100U54X AL150HDd
Energy LSIG 6.2E 150 A HDL36150U54X HGL36150U54X HJL36150U54X HLL36150U54X HRL36150U54X
250 A JDL36250U54X JGL36250U54X JJL36250U54X JLL36250U54X JRL36250U54X AL250JDe
a Circuit breakers with J, L, and R interrupting ratings are CSA/UL certified as current limiting.
b Refer to catalogue 0611CT1001 for circuit breakers with field-interchangeable trip units
DE3

c For 100% rated circuit breakers, add a “C” in the 9th character place (for example, HGL36150CU31X, JGL36250CU43X)
100% rated H- and J-frame circuit breakers have copper lugs and can only be used with copper wire.
d AL150HD wire range is 14–3/0 AWG Al or Cu.
e AL250JD wire range is 3/0 AWG–350 kcmil Al or Cu.
f 3P circuit breakers with this trip unit can be used for 2P applications. LSI trip unit has fixed long time and short time delays.
g For applications requiring communications see page DE3-43 .

H- and J-Frame Termination Options


Termination Letter
A - I-Line (See Section 5)
F = No Lugs (includes terminal nut kit on both ends)
For factory-installed
L = Lugs both ends
termination, place termination
M = Lugs ON end Terminal Nut Kit OFF end
letter in the third block of the
P = Lugs OFF end Terminal Nut Kit ON end
circuit breaker catalog number.
N = Plug-in h HDL36015T
D = Drawout h
Termination Letter
S = Rear Connected h
h For N and D details, refer to page DE3-44. For S details, refer to page DE3-40.

H-Frame H- and J-Frame Interrupting Ratings


Micrologic™ Trip Unit
Interrupting Rating
Voltage
D G J L R
240 Vac 25 KA 65 kA 100 kA 125 kA 200 kA
480 Vac 18 kA 35 kA 65 kA 100 kA 200 kA
600 Vac 14 kA 18 kA 25 kA 50 kA 100 kA
5 .2 E

.9 5 .9 6
0 .9 4 .9 7
>11
>30 .9 3 .9 8
.9 2
% Ir 1
Io )
.9
>30
A Ir (4x
M icor lo g ic

5
3 6
2 .5 8
2 10
1 .5 x Ir )
Is d(

H-Frame Circuit Breaker with


J-Frame
Optional FDM and IFM Modules
Micrologic™ Trip Unit

Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page DE3-33


Optional Lugs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page DE3-36
Micrologic Trip Unit Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page DE3-40
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page DE3-45
Enclosures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page DE3-46

11/18
DE3-22
08/21
Moulded Case Circuit Breakers
Class 0734 / Refer to Catalogs: 0734CT0201 Q-Frame Circuit Breakers

Q-framea—250 A, Thermal-magnetic Circuit Breaker (240 Vac)


AC Magnetic
B Interrupting D Interrupting G Interrupting J Interrupting ✭
Ampere Trip Settings Terminal Wire
Rating Catalogue Catalogue Catalogue Catalogue Range ■
Hold Trip
Number Number Number Number
2-pole, 240 Vac
70 1000 1800 QBL22070 QDL22070 QGL22070 QJL22070
80 1000 1800 QBL22080 QDL22080 QGL22080 QJL22080
90 1000 1800 QBL22090 QDL22090 QGL22090 QJL22090
100 1200 2400 QBL22100 QDL22100 QGL22100 QJL22100
110 1200 2400 QBL22110 QDL22110 QGL22110 QJL22110
#4 AWG - 300 kcmil
125 1200 2400 QBL22125 QDL22125 QGL22125 QJL22125 Al/Cu
150 1200 2400 QBL22150 QDL22150 QGL22150 QJL22150
QBL 2P 175 1200 2400 QBL22175 QDL22175 QGL22175 QJL22175
200 1200 2400 QBL22200 QDL22200 QGL22200 QJL22200
70–250 A 225 1200 2400 QBL22225 QDL22225 QGL22225 QJL22225
250 1200 2400 QBL22250■ QDL22250■ QGL22250■ QJL22250■
3-pole, 240 Vac
70 1000 1800 QBL32070 QDL32070 QGL32070 QJL32070
80 1000 1800 QBL32080 QDL32080 QGL32080 QJL32080
90 1000 1800 QBL32090 QDL32090 QGL32090 QJL32090
QBL32100 QDL32100 QGL32100 QJL32100

CIRCUIT BREAKERS
100 1200 2400
110 1200 2400 QBL32110 QDL32110 QGL32110 QJL32110
#4 AWG - 300 kcmil
125 1200 2400 QBL32125 QDL32125 QGL32125 QJL32125 Al/Cu
150 1200 2400 QBL32150 QDL32150 QGL32150 QJL32150
175 1200 2400 QBL32175 QDL32175 QGL32175 QJL32175
200 1200 2400 QBL32200 QDL32200 QGL32200 QJL32200
225 1200 2400 QBL32225 QDL32225 QGL32225 QJL32225
250 1200 2400 QBL32250■ QDL32250■ QGL32250■ QJL32250■
▲ Replacement lugs and electrical accessories are not available for Q-frame circuit breakers.
■ 250 A lugs are suitable for copper conductors only.
– Refer to Catalogue 0734CT0201 for details.

DE3
QBL 3P
Q-Frame Termination Options
70–250 A
Termination Letter
A = I-Line (See Section 5)
For factory-installed termination,
E = Bolt-on I-Line (See Section 5)
place termination letter in the
F = No lugs
third block of the circuit breaker
L = Lugs both ends
catalog number.
M = Lugs ON end, studs on OFF end
QGL32200
P = Lugs OFF end, studs on ON end
Termination Letter
– Add TS suffix for studs on both ends without nuts and washers. See Catalogue
0734CT0201 for additional information.

Q-Frame Interrupting Ratings (kA)


Voltage QB QD QG QJ
240 V 10 25 65 100✭
480 V ... ... ... ...
600 V ... ... ... ...

✭ 3-pole QJ circuit breakers are rated at 208Y/120 Vac only.

Dimensions DE3-44
Enclosures DE3-47

11/18
08/21
DE3-23
Moulded Case Circuit Breakers
Q4L - LAL - LHL

AC Magnetic Standard
Ampere Two Pole Three Pole
Trip Settings Lug Kit
Rating
Amperes Catalogue No. Price Catalogue No. Price Wire Range
400 Ampere Frame
Q4L Standard Interrupting
Low High 240Vac 240Vac
250 1250 2500 Q4L2250 Q4L3250 AL400LA
300 1500 3000 Q4L2300 Q4L3300 1-#1-600 kcmil or
350 1750 3500 Q4L2350 Q4L3350 2-#1-250 kcmil
400 2000 4000 Q4L2400 Q4L3400 AL400LA
LAL Standard Interrupting
Low High 600Vac, 250Vdc 600Vac, 250Vdc
125 625 1250 LAL26125 LAL36125
150 750 1500 LAL26150 LAL36150
175 875 1750 LAL26175 LAL36175
200 1000 2000 LAL26200 LAL36200 AL400LA
225 1125 2250 LAL26225 LAL36225 1-#1-600 kcmil or
250 1250 2500 LAL26250 LAL36250 2-#1-250 kcmil
300 1500 3000 LAL26300 LAL36300
350 1750 3500 LAL26350 LAL36350
400 2000 4000 LAL26400 LAL36400
LHL High Interrupting 400 A L-Frame
CIRCUIT BREAKERS

Low High 600Vac, 250Vdc 600Vac, 250Vdc


125 625 1250 LHL26125 LHL36125
150 750 1500 LHL26150 LHL36150
175 875 1750 LHL26175 LHL36175
200 1000 2000 LHL26200 LHL36200 AL400LA
225 1125 2250 LHL26225 LHL36225 1-#1-600 kcmil or
250 1250 2500 LHL26250 LHL36250 2-#1-250 kcmil
300 1500 3000 LHL26300 LHL36300
350 1750 3500 LHL26350 LHL36350
400 2000 4000 LHL26400 LHL36400
DE3

Accessories:
Optional Mechanical Lug Kit for (1) 350-750 kcmil wire Cat. No. AL400LH7
Handle Padlock Attachment (locks ON or OFF) Cat. No. HPALM

CSA Certified Interrupting Rating


RMS Symmetrical Amperes
Breaker System Voltage AC DC
Cat. No.
Prefix 240 480 600 125 250
Q4L 25k
LAL 42k 30k 22k 10k 10k
LHL 65k 35k 25k 50k 50k

Enclosures - DE3-47
Dimensions - DE3-45

11/18
DE3-24
08/21
PowerPact™ Circuit Breakers
Class 611 / Refer to Catalogs: 0611CT1001 L-Frame Circuit Breakers
L-Frame 600 A Circuit Breakers with Lugs and Factory-Sealed Electronic Trip Units Suitable for Reverse Connectionag
Interrupting Rating (2nd Letter of Catalog Number)
Electronic Trip Unit
D G Jc Lc Rc
Sensor Terminal
Rating
Type Function Trip Unit
Catalogue Catalogue Catalogue Catalogue
Catalogue Numberb
Number b Number b Number b Number b

600 Vac, 50/60 Hz, 3P


250 A LDL36250U31X LGL36250U31X LJL36250U31X LLL36250U31X LRL36250U31X AL400L61K3e
Micrologic LI 3.3d
Standard 400 A LDL36400U31X LGL36400U31X LJL36400U31X LLL36400U31X LRL36400U31X
AL600LS52K3f
600 A LDL36600U31X LGL36600U31X LJL36600U31X LLL36600U31X LRL36600U31X
250 A LDL36250U33X LGL36250U33X LJL36250U33X LLL36250U33X LRL36250U33X AL400L61K3e
Micrologic
Standard LSI 3.3Sd 400 A LDL36400U33X LGL36400U33X LJL36400U33X LLL36400U33X LRL36400U33X AL600LS52K3f
600 A LDL36600U33X LGL36600U33X LJL36600U33X LLL36600U33X LRL36600U33X
Micrologic LSI 5.3A 400 A LDL36400U43X LGL36400U43X LJL36400U43X LLL36400U43X LRL36400U43X
Ammeter 600 A LDL36600U43X LGL36600U43X LJL36600U43X LLL36600U43X LRL36600U43X
Micrologic 400 A LDL36400U53X LGL36400U53X LJL36400U53X LLL36400U53X LRL36400U53X
LSI 5.3E
Energy 600 A LDL36600U53X LGL36600U53X LJL36600U53X LLL36600U53X LRL36600U53X
AL600LS52K3f
Micrologic 400 A LDL36400U44X LGL36400U44X LJL36400U44X LLL36400U44X LRL36400U44X
Ammeter LSIG 6.3A 600 A LDL36600U44X LGL36600U44X LJL36600U44X LLL36600U44X LRL36600U44X

CIRCUIT BREAKERS
Micrologic 400 A LDL36400U54X LGL36400U54X LJL36400U54X LLL36400U54X LRL36400U54X
Energy LSIG 6.3E 600 A LDL36600U54X LGL36600U54X LJL36600U54X LLL36600U54X LRL36600U54X
600 Vac, 50/60 Hz, 4P
250 A LDL46250U31X LGL46250U31X LJL46250U31X LLL46250U31X LRL46250U31X AL400L61K4e
Micrologic LI 3.3
Standard 400 A LDL46400U31X LGL46400U31X LJL46400U31X LLL46400U31X LRL46400U31X
AL600LS52K4f
600 A LDL46600U31X LGL46600U31X LJL46600U31X LLL46600U31X LRL46600U31X
250 A LDL46250U33X LGL46250U33X LJL46250U33X LLL46250U33X LRL46250U33X AL400L61K4e
Micrologic
Standard LSI 3.3S 400 A LDL46400U33X LGL46400U33X LJL46400U33X LLL46400U33X LRL46400U33X AL600LS52K4f
600 A LDL46600U33X LGL46600U33X LJL46600U33X LLL46600U33X LRL46600U33X

DE3
Micrologic LSI 5.3A 400 A LDL46400U43X LGL46400U43X LJL46400U43X LLL46400U43X LRL46400U43X
Ammeter 600 A LDL46600U43X LGL46600U43X LJL46600U43X LLL46600U43X LRL46600U43X
Micrologic 400 A LDL46400U53X LGL46400U53X LJL46400U53X LLL46400U53X LRL46400U53X
Energy LSI 5.3E 600 A LDL46600U53X LGL46600U53X LJL46600U53X LLL46600U53X LRL46600U53X
AL600LS52K4f
Micrologic 400 A LDL46400U44X LGL46400U44X LJL46400U44X LLL46400U44X LRL46400U44X
Ammeter LSIG 6.3A 600 A LDL46600U44X LGL46600U44X LJL46600U44X LLL46600U44X LRL46600U44X
Micrologic LSIG 6.3E 400 A LDL46400U54X LGL46400U54X LJL46400U54X LLL46400U54X LRL46400U54X
Energy 600 A LDL46600U54X LGL46600U54X LJL46600U54X LLL46600U54X LRL46600U54X
a Refer to catalogue 0611CT1001 for circuit breakers with field-interchangeable trip units
b For 100% rated circuit breakers (250 A and 400 A only), add a “C” in the 9th character place (for example, LGL36400CU31X)
c Circuit breakers with J, L, and R interrupting ratings are CSA/UL certified as current limiting.
d 3P circuit breakers with this trip unit can be used for 2P applications. LSI trip unit has fixed long time and short time delays.
e AL400L61K3 terminal wire ranges are (1) 2 AWG–600 kcmil Cu or 1) 2 AWG–500 kcmil Al.
f AL600LS52K3 terminal wire range is (2) 2/0 AWG–500 kcmil Al/Cu.
g For applications requiring communicatins see page DE3-43.

Termination Options Interrupting Ratings


Termination Termination Option
Letter Interrupting Rating
Voltage
A I-Line (See Section 5) D G J L R
F No lugs 240 Vac 25 kA 65 kA 100 kA 125 kA 200 kA
L Lugs both ends 480 Vac 18 kA 35 kA 65 kA 100 kA 200 kA
M Lugs ON end, terminal nut kit OFF end 600 Vac 14 kA 18 kA 25 kA 50 kA 100 kA
P Lugs OFF end, terminal nut kit ON end
Nh Plug In
Dh Drawout
Sh Rear Connected

L-Frame Circuit Breaker For factory-installed termination, place termination letter


in the third block of the circuit breaker catalog number.
LGL36600U44X Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page DE3-33
Optional Lugs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page DE3-36
Termination Letter Micrologic Trip Unit Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . page DE3-39
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page DE3-45
h For N and D details, please refer to page DE3-39. For S details, please Enclosures. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page DE3-46
refer to page DE3-35.

11/18
08/21
DE3-25
PowerPact™ Circuit Breakers
M-Frame Circuit Breakers Class 612 / Refer to Catalog 0612CT0101

Frame—800 A, Standard Rated, Basic Electronic Trip System Type ET 1.0 aFactory Sealed
Trip Unit
Adjustable Instantaneous G Interrupting J Interrupting Terminal
Ampere Trip Range Wire
Rating Range
Low High Catalogue Number Catalogue Number Price

2-pole, 600 Vac 50/60 Hz


300 600 3000 MGL26300 MJL26300
350 700 3500 MGL26350 MJL26350
400 800 4000 MGL26400 MJL26400 AL800M23K
450 900 4500 MGL26450 MJL26450 3–3/0
500 1000 5000 MGL26500 MJL26500 through
600 1200 6000 MGL26600 MJL26600 500 kcmil
Al/Cu
700 1400 7000 MGL26700 MJL26700
800 1600 8000 MGL26800 MJL26800
M-Frame Circuit Breaker 3-pole, 600 Vac 50/60 Hz
300 600 3000 MGL36300 MJL36300
350 700 3500 MGL36350 MJL36350
400 800 4000 MGL36400 MJL36400 AL800M23K
450 900 4500 MGL36450 MJL36450 3–3/0
500 1000 5000 MGL36500 MJL36500 through
600 1200 6000 MGL36600 MJL36600 500 kcmil
Al/Cu
CIRCUIT BREAKERS

700 1400 7000 MGL36700 MJL36700


800 1600 8000 MGL36800 MJL36800
a The ET 1.0 trip unit cannot be field replaced or have the long-time trip point setting adjusted. It is considered an electronic equivalent of a thermal-
magnetic circuit breaker.

Termination Options
DE3

Termination
Letter
Termination Option M-Frame Interrupting Ratings (kA)
A I-Line (See Section 5) Voltage G J
F No lugs 240 V 65 100
L Lugs both ends
480 V 35 65
M Lugs ON end, terminal nut kit OFF end
P Lugs OFF end, terminal nut kit ON end 600 V 18 25

For factory-installed termination, place termination letter in


the third block of the circuit breaker catalog number.
MGL36400 Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page DE3-33
Optional Lugs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page DE3-36
Termination Letter Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page DE3-45
Enclosures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page DE3-48

11/18
08/21
DE3-26
PowerPact™ Circuit Breakers
Class 612 / Refer to Catalog 0612CT0101 P-Frame Circuit Breakers
P Frame - 1200A, (600 Vac, 50/60 Hz) 3P a Circuit Breaker with Electronic Trip Unit
Electronic Trip Unit G Interrupting J Interrupting L Interrupting c K Interrupting
Sensor Terminal
Rating Catalogue Catalogue Catalogue Catalogue Wire Range
Type Function Trip Unit Number.b Number b Number b Price Number b
600 A PGL36060 PJL36060 PLL34060 PKL36060 AL800M23K
Basic Electronic
Trip Unit Fixed long-time, 800 A PGL36080 PJL36080 PLL34080 PKL36080 (3) 3/0 AWG–500 kcmil Al or Cu
Adjustable ET1.0I
(Not 1000 A PGL36100 PJL36100 PLL34100 PKL36100 AL1200P25K
Instantaneous
Interchangeable) (4) 3/0 AWG–500 kcmil Al or Cu
1200 A PGL36120 PJL36120 PLL34120 PKL36120
250 PGL36025U31A PJL36025U31A PLL34025U31A PKL36025U31A
400 PGL36040U31A PJL36040U31A PLL34040U31A PKL36040U31A AL800M23K
600 PGL36060U31A PJL36060U31A PLL34060U31A PKL36060U31A (3) 3/0 AWG–500 kcmil Al or Cu
LI 3.0
800 PGL36080U31A PJL36080U31A PLL34080U31A PKL36080U31A
1000 PGL36100U31A PJL36100U31A PLL34100U31A PKL36100U31A AL1200P25K
Micrologic
Interchangeable 1200 PGL36120U31A PJL36120U31A PLL34120U31A PKL36120U31A (4) 3/0 AWG–500 kcmil Al or Cu
Standard 250 PGL36025U33A PJL36025U33A PLL34025U33A PKL36025U33A
Trip Unit 400 PGL36040U33A PJL36040U33A PLL34040U33A PKL36040U33A AL800M23K
600 PGL36060U33A PJL36060U33A PLL34060U33A PKL36060U33A (3) 3/0 AWG–500 kcmil Al or Cu
LSI 5.0
800 PGL36080U33A PJL36080U33A PLL34080U33A PKL36080U33A
1000 PGL36100U33A PJL36100U33A PLL34100U33A PKL36100U33A AL1200P25K
1200 PGL36120U33A PJL36120U33A PLL34120U33A PKL36120U33A (4) 3/0 AWG–500 kcmil Al or Cu
250 PGL36025U41A PJL36025U41A PLL34025U41A PKL36025U41A
400 PGL36040U41A PJL36040U41A PLL34040U41A PKL36040U41A AL800M23K

CIRCUIT BREAKERS
600 PGL36060U41A PJL36060U41A PLL34060U41A PKL36060U41A (3) 3/0 AWG–500 kcmil Al or Cu
LI 3.0A
800 PGL36080U41A PJL36080U41A PLL34080U41A PKL36080U41A
1000 PGL36100U41A PJL36100U41A PLL34100U41A PKL36100U41A AL1200P25K
1200 PGL36120U41A PJL36120U41A PLL34120U41A PKL36120U41A (4) 3/0 AWG–500 kcmil Al or Cu
250 PGL36025U43A PJL36025U43A PLL34025U43A PKL36025U43A
Micrologic 400 PGL36040U43A PJL36040U43A PLL34040U43A PKL36040U43A AL800M23K
Interchangeable 600 PGL36060U43A PJL36060U43A PLL34060U43A PKL36060U43A (3) 3/0 AWG–500 kcmil Al or Cu
LSI 5.0A
Ammeter 800 PGL36080U43A PJL36080U43A PLL34080U43A PKL36080U43A
Trip Unit 1000 PGL36100U43A PJL36100U43A PLL34100U43A PKL36100U43A AL1200P25K
1200 PGL36120U43A PJL36120U43A PLL34120U43A PKL36120U43A (4) 3/0 AWG–500 kcmil Al or Cu

DE3
250 PGL36025U44A PJL36025U44A PLL34025U44A PKL36025U44A
400 PGL36040U44A PJL36040U44A PLL34040U44A PKL36040U44A AL800M23K
600 PGL36060U44A PJL36060U44A PLL34060U44A PKL36060U44A (3) 3/0 AWG–500 kcmil Al or Cu
LSIG 6.0A
800 PGL36080U44A PJL36080U44A PLL34080U44A PKL36080U44A
1000 PGL36100U44A PJL36100U44A PLL34100U44A PKL36100U44A AL1200P25K
1200 PGL36120U44A PJL36120U44A PLL34120U44A PKL36120U44A (4) 3/0 AWG–500 kcmil Al or Cu
250 PGL36025U63AE1 PJL36025U63AE1 PLL34025U63AE1 PKL36025U63AE1
400 PGL36040U63AE1 PJL36040U63AE1 PLL34040U63AE1 PKL36040U63AE1 AL800M23K
600 PGL36060U63AE1 PJL36060U63AE1 PLL34060U63AE1 PKL36060U63AE1 (3) 3/0 AWG–500 kcmil Al or Cu
LSI 5.0P
800 PGL36080U63AE1 PJL36080U63AE1 PLL34080U63AE1 PKL36080U63AE1
1000 PGL36100U63AE1 PJL36100U63AE1 PLL34100U63AE1 PKL36100U63AE1 AL1200P25K
Micrologic
Interchangeable 1200 PGL36120U63AE1 PJL36120U63AE1 PLL34120U63AE1 PKL36120U63AE1 (4) 3/0 AWG–500 kcmil Al or Cu
Power 250 PGL36025U64AE1 PJL36025U64AE1 PLL34025U64AE1 PKL36025U64AE1
Trip Unit 400 PGL36040U64AE1 PJL36040U64AE1 PLL34040U64AE1 PKL36040U64AE1 AL800M23K
600 PGL36060U64AE1 PJL36060U64AE1 PLL34060U64AE1 PKL36060U64AE1 (3) 3/0 AWG–500 kcmil Al or Cu
LSIG 6.0P
800 PGL36080U64AE1 PJL36080U64AE1 PLL34080U64AE1 PKL36080U64AE1
1000 PGL36100U64AE1 PJL36100U64AE1 PLL34100U64AE1 PKL36100U64AE1 AL1200P25K
1200 PGL36120U64AE1 PJL36120U64AE1 PLL34120U64AE1 PKL36120U64AE1 (4) 3/0 AWG–500 kcmil Al or Cu
250 PGL36025U73AE1 PJL36025U73AE1 PLL34025U73AE1 PKL36025U73AE1
400 PGL36040U73AE1 PJL36040U73AE1 PLL34040U73AE1 PKL36040U73AE1 AL800M23K
600 PGL36060U73AE1 PJL36060U73AE1 PLL34060U73AE1 PKL36060U73AE1 (3) 3/0 AWG–500 kcmil Al or Cu
LSI 5.0H
800 PGL36080U73AE1 PJL36080U73AE1 PLL34080U73AE1 PKL36080U73AE1
1000 PGL36100U73AE1 PJL36100U73AE1 PLL34100U73AE1 PKL36100U73AE1 AL1200P25K
Micrologic
Interchangeable 1200 PGL36120U73AE1 PJL36120U73AE1 PLL34120U73AE1 PKL36120U73AE1 (4) 3/0 AWG–500 kcmil Al or Cu
Harmonic 250 PGL36025U74AE1 PJL36025U74AE1 PLL34025U74AE1 PKL36025U74AE1
Trip Unit
400 PGL36040U74AE1 PJL36040U74AE1 PLL34040U74AE1 PKL36040U74AE1 AL800M23K
600 PGL36060U74AE1 PJL36060U74AE1 PLL34060U74AE1 PKL36060U74AE1 (3) 3/0 AWG–500 kcmil Al or Cu
LSIG 6.0H
800 PGL36080U74AE1 PJL36080U74AE1 PLL34080U74AE1 PKL36080U74AE1
1000 PGL36100U74AE1 PJL36100U74AE1 PLL34100U74AE1 PKL36100U74AE1 AL1200P25K
1200 PGL36120U74AE1 PJL36120U74AE1 PLL34120U74AE1 PKL36120U74AE1 (4) 3/0 AWG–500 kcmil Al or Cu

a For 2P and 4P information see Catalog 0612CT0101.


b For 100% rated circuit breakers add a “C” in the 9th character place. For example, the catalog number for a 100% trip unit with LI trip functions at 250A would be PGL36025CU31A. 100%
ratings are not available for circuit breakers with ET1.0 Trip Units.
c P-frame L-interrupting is available in 480 Vac only.

P-Frame Termination Options P-Frame and R-Frame Interrupting Ratings


Termination Letter P-Frame Interrupting Rating R-Frame Interrupting Rating
Voltage
F = No Lugs (Includes terminal nut kit on both ends) G J K L G J K L
For factory-installed termination, place
L = Lugs both ends termination letter in the third block of 240 Vac 65 kA 100 kA 65 kA 125 kA 65 kA 100 kA 65 kA 125 kA
M = Lugs ON end, terminal nut kit OFF end the circuit breaker catalog number. 480 Vac 35 kA 65 kA 50 kA 100 kA 35 kA 65 kA 65 kA 100 kA
P = Lugs OFF end, terminal nut kit ON end 600 Vac 18 kA 25 kA 50 kA 18 kA 25 kA 65 kA 50 kA
D = Drawout PGL36040U41A
A = I-Line (See Section 5) Termination Letter
R-frame catalog numbers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page DE3-28
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page DE3-45
Trip Unit Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page DE3-41
Optional Lugs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page DE3-36
Alternate Rating Plugs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page DE3-42
Enclosure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page DE3-48
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page DE3-33

11/18
08/21
DE3-27
PowerPact™ Circuit Breakers
R-Frame Circuit Breakers Class 612 / Refer to Catalog 0612CT0101

R-frame—3000 A (600 Vac, 50/60 Hz) 3Pa Circuit Breaker with Electronic Trip Unit
Electronic Trip Unit Sensor G Interrupting c J Interrupting c L Interrupting c K Interrupting c
Type Function Trip Unit Rating Catalogue Number b Catalogue Number b Catalogue Number b Catalogue Number b
Fixed 1200 A RGF36120 RJF36120 RLF36120 RKF36120
Basic Electronic Trip 1600 A RGF36160 RJF36160 RLF36160 RKF36160
Unit (Not long-time, ET1.0I
Interchangeable) Adjustable 2000 A RGF36200 RJF36200 RLF36200 RKF36200
Instantaneous
2500 A RGF36250 RJF36250 RLF36250 RKF36250
600 RGF36060U31A RJF36060U31A RLF36060U31A RKF36060U31A
800 RGF36080U31A RJF36080U31A RLF36080U31A RKF36080U31A
1000 RGF36100U31A RJF36100U31A RLF36100U31A RKF36100U31A
1200 RGF36120U31A RJF36120U31A RLF36120U31A RKF36120U31A
LI 3.0
1600 RGF36160U31A RJF36160U31A RLF36160U31A RKF36160U31A
2000 RGF36200U31A RJF36200U31A RLF36200U31A RKF36200U31A
2500 RGF36250U31A RJF36250U31A RLF36250U31A RKF36250U31A
Micrologic 3000 RGF36300U31A RJF36300U31A RLF36300U31A RKF36300U31A
Interchangeable
Standard Trip Unit 600 RGF36060U33A RJF36060U33A RLF36060U33A RKF36060U33A
800 RGF36080U33A RJF36080U33A RLF36080U33A RKF36080U33A
1000 RGF36100U33A RJF36100U33A RLF36100U33A RKF36100U33A
1200 RGF36120U33A RJF36120U33A RLF36120U33A RKF36120U33A
LSI 5.0
1600 RGF36160U33A RJF36160U33A RLF36160U33A RKF36160U33A
2000 RGF36200U33A RJF36200U33A RLF36200U33A RKF36200U33A
2500 RGF36250U33A RJF36250U33A RLF36250U33A RKF36250U33A
CIRCUIT BREAKERS

3000 RGF36300U33A RJF36300U33A RLF36300U33A RKF36300U33A


600 RGF36060U41A RJF36060U41A RLF36060U41A RKF36060U41A
800 RGF36080U41A RJF36080U41A RLF36080U41A RKF36080U41A
1000 RGF36100U41A RJF36100U41A RLF36100U41A RKF36100U41A
1200 RGF36120U41A RJF36120U41A RLF36120U41A RKF36120U41A
LI 3.0A
1600 RGF36160U41A RJF36160U41A RLF36160U41A RKF36160U41A
2000 RGF36200U41A RJF36200U41A RLF36200U41A RKF36200U41A
2500 RGF36250U41A RJF36250U41A RLF36250U41A RKF36250U41A
3000 RGF36300U41A RJF36300U41A RLF36300U41A RKF36300U41A
600 RGF36060U43A RJF36060U43A RLF36060U43A RKF36060U43A
DE3

800 RGF36080U43A RJF36080U43A RLF36080U43A RKF36080U43A


Micrologic 1000 RGF36100U43A RJF36100U43A RLF36100U43A RKF36100U43A
Interchangeable 1200 RGF36120U43A RJF36120U43A RLF36120U43A RKF36120U43A
LSI 5.0A
Ammeter 1600 RGF36160U43A RJF36160U43A RLF36160U43A RKF36160U43A
Trip Unit
2000 RGF36200U43A RJF36200U43A RLF36200U43A RKF36200U43A
2500 RGF36250U43A RJF36250U43A RLF36250U43A RKF36250U43A
3000 RGF36300U43A RJF36300U43A RLF36300U43A RKF36300U43A
600 RGF36060U44A RJF36060U44A RLF36060U44A RKF36060U44A
800 RGF36080U44A RJF36080U44A RLF36080U44A RKF36080U44A
1000 RGF36100U44A RJF36100U44A RLF36100U44A RKF36100U44A
1200 RGF36120U44A RJF36120U44A RLF36120U44A RKF36120U44A
LSIG 6.0A
1600 RGF36160U44A RJF36160U44A RLF36160U44A RKF36160U44A
2000 RGF36200U44A RJF36200U44A RLF36200U44A RKF36200U44A
2500 RGF36250U44A RJF36250U44A RLF36250U44A RKF36250U44A
3000 RGF36300U44A RJF36300U44A RLF36300U44A RKF36300U44A
600 RGF36060U63AE1 RJF36060U63AE1 RLF36060U63AE1 RKF36060U63AE1
800 RGF36080U63AE1 RJF36080U63AE1 RLF36080U63AE1 RKF36080U63AE1
1000 RGF36100U63AE1 RJF36100U63AE1 RLF36100U63AE1 RKF36100U63AE1
1200 RGF36120U63AE1 RJF36120U63AE1 RLF36120U63AE1 RKF36120U63AE1
LSI 5.0P
1600 RGF36160U63AE1 RJF36160U63AE1 RLF36160U63AE1 RKF36160U63AE1
2000 RGF36200U63AE1 RJF36200U63AE1 RLF36200U63AE1 RKF36200U63AE1
2500 RGF36250U63AE1 RJF36250U63AE1 RLF36250U63AE1 RKF36250U63AE1
Micrologic 3000 RGF36300U63AE1 RJF36300U63AE1 RLF36300U63AE1 RKF36300U63AE1
Interchangeable Power
Trip Unit 600 RGF36060U64AE1 RJF36060U64AE1 RLF36060U64AE1 RKF36060U64AE1
800 RGF36080U64AE1 RJF36080U64AE1 RLF36080U64AE1 RKF36080U64AE1
1000 RGF36100U64AE1 RJF36100U64AE1 RLF36100U64AE1 RKF36100U64AE1
1200 RGF36120U64AE1 RJF36120U64AE1 RLF36120U64AE1 RKF36120U64AE1
LSIG 6.0P
1600 RGF36160U64AE1 RJF36160U64AE1 RLF36160U64AE1 RKF36160U64AE1
2000 RGF36200U64AE1 RJF36200U64AE1 RLF36200U64AE1 RKF36200U64AE1
3000 RGF36250U64AE1 RJF36250U64AE1 RLF36250U64AE1 RKF36250U64AE1
3000 RGF36300U64AE1 RJF36300U64AE1 RLF36300U64AE1 RKF36300U64AE1
600 RGF36060U73AE1 RJF36060U73AE1 RLF36060U73AE1 RKF36060U73AE1
800 RGF36080U73AE1 RJF36080U73AE1 RLF36080U73AE1 RKF36080U73AE1
1000 RGF36100U73AE1 RJF36100U73AE1 RLF36100U73AE1 RKF36100U73AE1
1200 RGF36120U73AE1 RJF36120U73AE1 RLF36120U73AE1 RKF36120U73AE1
LSI 5.0H
1600 RGF36160U73AE1 RJF36160U73AE1 RLF36160U73AE1 RKF36160U73AE1
2000 RGF36200U73AE1 RJF36200U73AE1 RLF36200U73AE1 RKF36200U73AE1
2500 RGF36250U73AE1 RJF36250U73AE1 RLF36250U73AE1 RKF36250U73AE1
Micrologic 3000 RGF36300U73AE1 RJF36300U73AE1 RLF36300U73AE1 RKF36300U73AE1
Interchangeable
Harmonic Trip Unit 600 RGF36060U74AE1 RJF36060U74AE1 RLF36060U74AE1 RKF36060U74AE1
800 RGF36080U74AE1 RJF36080U74AE1 RLF36080U74AE1 RKF36080U74AE1
1000 RGF36100U74AE1 RJF36100U74AE1 RLF36100U74AE1 RKF36100U74AE1
1200 RGF36120U74AE1 RJF36120U74AE1 RLF36120U74AE1 RKF36120U74AE1
LSIG 6.0H
1600 RGF36160U74AE1 RJF36160U74AE1 RLF36160U74AE1 RKF36160U74AE1
2000 RGF36200U74AE1 RJF36200U74AE1 RLF36200U74AE1 RKF36200U74AE1
2500 RGF36250U74AE1 RJF36250U74AE1 RLF36250U74AE1 RKF36250U74AE1
3000 RGF36300U74AE1 RJF36300U74AE1 RLF36300U74AE1 RKF36300U74AE1
Note: R-frame circuit breakers can be bus- or cable-connected. For cable connections, optional terminal pad kit RLTB or equivalent bus structure is required. Each RLTB kit contains terminal pads
for one end of the circuit breaker only and has provisions for mounting a maximum of 8 lugs per phase (9 lugs for 3000 A). RLTB kits are included with 2500 A 100% rated circuit breakers.
The RL3TB kits are included with the 3000 A, 80% and 100% rated circuit breakers. For other circuit breakers, order terminal pad kit (RLTB) and optional lugs separately. See pages
DE3-36–DE3-38.
a For 2P and 4P information see Catalog 0612CT0101.
b Listed catalogue numbers are for 80% rated circuit breakers. For 100% rated circuit breakers add a “C” in the 9th character place. For example, the catalogue number for a 100% standard
trip unit with LI trip functions at 2500A would be RGF36250CU31A. 100% ratings are not available for circuit breakers with ET1.0 Trip Units.
c See page DE3-27 for interrupting ratings table.

DE3-28
11/18
08/21
Motor Circuit Protectors and Motor Protector Circuit Breakers
Class 611 / Refer to Catalog 0611CT1001 PowerPact™ H- and J-Frame

PowerPact H- and J-frame electronic Motor Circuit Protectors (MCP) are magnetic-only
instantaneous-trip circuit breakers. They are designed to offer short circuit protection and
are Canadian Electrical Code (CEC) and National Electrical Code (NEC) compliant when
installed as part of a combination controller having motor overload protection. MCP circuit
breakers accept the same accessories and terminals as the equivalent thermal-magnetic
circuit breakers.

Determine the hp rating from the nameplate of the motor. Select a MCP with an ampere
rating recommended for the hp and voltage involved. When using the automatic settings the
MCP microprocessor automatically adjusts the trip settings for both current and time to
align with the start-up characteristic for the motor type, whether it is a standard or energy-
efficient motor. This includes a dampening means to accommodate a transient motor in-
rush current without nuisance tripping of the circuit breaker.
Stan
dard

rgy
ient
Effic ace
Energie Efficiente
Energia Efic
Ene
H- and J-frame Electronic Motor Circuit Protectors (MCP)
J Interrupting L Interrupting R Interrupting
Full Load Adjustable (See SCCR Table (See SCCR Table (See SCCR Table
Frame Current Amperes Instantaneous Suffix Below) Below) Below)
Range Trip Range
Cat. No. Cat. No. Cat. No.
30 A 1.5–25 A 9–325 A M71 HJL36030M71 HLL36030M71 HRL36030M71
50 A 14–42 A 84–546 A M72 HJL36050M72 HLL36050M72 HRL36050M72

CIRCUIT BREAKERS
Standard H-frame
Energy Efficient
100 A 30–80 A 180–1040 A M73 HJL36100M73 HLL36100M73 HRL36100M73
Energie Efficace
Energia Eficiente 150 A 58–130 A 348–1690 A M74 HJL36150M74 HLL36150M74 HRL36150M74
J-frame 250 A 114–217 A 684–2500 A M75 JJL36250M75 JLL36250M75 JRL36250M75

Maximum Rating or Setting of Motor Protective Devices


Percentage of Full-load Current
Type of Motor
Setting Not to Exceed
A, B, C, D Standard 800% 1300%
t

DE3
B, E Energy Efficient 1100% 1700%
Based on 2005 NEC Table 430.52.
See NEC Exception No. 1 to Table 430.52. The NEC 1300% maximum setting may be inadequate for instantaneous
trip circuit breakers to withstand current surges typical of the magnetization current of autotransformer type reduced
voltage starters, or open transition wye-delta starters during transfer from “start” to “run,” constant hp multi-speed
motors, and motors labeled “high efficiency.”
I
Motor Type / Tipo de Motor / Type de Moteur MCP Selection by HP Ratings of Induction-type Squirrel-Cage and
Wound-rotor Motors
Standard
3Ø 60 Hz Voltages
Energy Efficient Full-Load Amperes Suffix
Energie Efficace 200 Vac 230 Vac 460 Vac 575 Vac
Energia Eficiente
.5–5 .5–7.5 .75–15 1–20 1.5–25 M71
5–10 5–15 10–30 15–40 14–42 M72
10–25 15–30 25–60 30–75 30–80 M73
20–40 25–50 50–100 60–125 58–130 M74
40–60 50–75 100–150 125–200 114–217 M75
Based on 2005 NEC Table 430.250.
Per NEC 430.3, part-winding motors should select two circuit breakers, each at not more than one-half the allowable
trip setting for the horsepower rating. The two circuit breakers should operate simultaneously as a disconnecting
means per NEC 430.103.
Listed voltages are rated motor voltages. Corresponding system voltages are 200 Vac, 220–240 Vac, 440–480 Vac
and 550–600 Vac. Select wire and circuit breakers based on horsepower rather than nameplate full-load current per
NEC 430.6 (A) for general motor applications.

Short Circuit Current Rating (SCCR)


Tested to meet NEC and UL508A requirements for short circuit current ratings as part of an
approved combination controller.

Short Circuit Current Ratings (SCCR)


J Interrupting L Interrupting
Contactor/Starter
200–240 Vac 480 Vac 600 Vac 200–240 Vac 480 Vac 600 Vac
Tesys D-line and F-line 100 kA 65 kA 25 kA 125 kA 100 kA 50 kA
NEMA Type S 100 kA 65 kA 25 kA 125 kA 100 kA 50 kA

Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page DE3-33


Optional Lugs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page DE3-36
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page DE3-45

11/18
08/21
DE3-29
Motor Protectors
Motor Circuit Protectors and Motor Protector Circuit Breakers Class 580, 585, 680, 685

Motor Circuit Protectors


Mag-Gard™ Motor Circuit Protectors (MCP) are instantaneous-trip magnetic-only circuit breakers. They have a single
adjustment which simultaneously sets the magnetic trip level of each individual pole. Mag-Gard™ circuit breakers
comply with CEC/NEC requirements for providing motor circuit protection when installed as part of a UL Listed
combination controller having motor overload protection. Interrupting ratings are established for these CSA/UL
Recognized Components only when they are used in combination with motor starters with properly sized overload
relays and contactors.
All Mag-Gard circuit breakers will accept the same lugs and accessories as equivalent circuit breakers. Mag-Gard
circuit breakers are available with I-Line construction.d High-interruption (H) construction Mag-Gard circuit breakers
(LHL) are also available.
Magnetic Only 3 Pole, 600 Vac, 50/60 Hzd—Three Device Solutionsb
Ampere Rating Trip Adjustablea 250 Vdc Multiplier Cat. No.
Motor Circuit Protector Unit Trip Range (A)
500–1000 A LAL3640022M
750–1600 A LAL3640028M
1000–2000 A LAL3640030M
LAL 400 1125–2250 A High = 1.2 LAL3640031M
1250–2500 A Low = 1.4 LAL3640032M
1500–3000 A LAL3640033M
CIRCUIT BREAKERS

1750–3500 A LAL3640035M
2000–4000 A LAL3640036M

For PowerPact L- and P-Frames, an instantaneous-only version of the electronic trip circuit breaker is also available for
motor circuit protection. These MCPs comply with CEC/NEC® requirements for providing short-circuit protection when
installed as part of a Listed combination controller having motor overload protection.
Magnetic Only 3 Pole, 600 Vac, 50/60 Hzd—Three Device Solutionsb
Interrupting Rating
Sensor Rating Trip Adjustablea G J L R
DE3

Unit Trip Range (A)


Cat. No. Cat. No. Cat. No. Cat. No.
PowerPact 400 500–1200% LGL36400M37X LJL36400M37X LLL36400M37X LRL36400M37X
1.3 M
L-Framed 600 500–1200% LGL36600M37X LJL36600M37X LLL36600M37X LRL36600M37X
600 1200–10000 A — PJL36060M68 PLL34060M68 —
Motor Protector Circuit PowerPact 800 1200–10000 A — PJL36080M68 PLL34080M68 —
Breaker PJL, PLLd 1000 1500–10000 A — PJL36100M69 PLL34100M69 —
1200 1800–10000 A — PJL36120M70 PLL34120M70 —
a CSA/UL magnetic trip tolerances are -20%/+30% from the nominal values shown.
b Three-device solutions are the traditional solutionss: motor circuit protector plus motor starter plus overload relay.
c 250 Vdc ratings are available. No CSA/UL component recognition
d These electronic magnetic only motor circuit protectors are available with I-Line constructions. Consult the factory.

Motor Protector Circuit Breakers


Motor protection circuit breakers provide built-in thermal and magnetic protection. They are used in two-device motor
feeder solutions to provide protection against short-circuits, overloads, and phase unbalance.

H-Frame (150 A), J-Frame (250 A) and L-Frame (600 A) Electronic Trip Motor Protector Circuit Breakers
(CSA/UL Ratings)—
Two Device Solutionse

Interrupting Rating
Full Load
Electronic
Trip Unit Frame Sensor Trip Amperes
Isd (x FLA) G J L R
Type Rating Unit Range
(FLA)
Cat. No. Cat. No. Cat. No. Cat. No.
30 14–25 5-13 x FLA HGL36030M38X HJL36030M38X HLL36030M38X HRL36030M38X
50 14–42 5-13 x FLA HGL36050M38X HJL36050M38X HLL36050M38X HRL36050M38X
H-Frame
100 2.2 M 30–80 5-13 x FLA HGL36100M38X HJL36100M38X HLL36100M38X HRL36100M38X
Standardf 150 58–130 5-13 x FLA HGL36150M38X HJL36150M38X HLL36150M38X HRL36150M38X
J-Frame 250 114–217 5-13 x FLA JGL36250M38X JJL36250M38X JLL36250M38X JRL36250M38X
400 190–348 5-13 x FLA LGL36400M38X LJL36400M38X LLL36400M38X LRL36400M38X
L-Frame 2.3 M
600 312–520 5-13 x FLA LGL36600M38X LJL36600M38X LLL36600M38X LRL36600M38X
e Two-device solutions (these electronic motor protector circuit breakers include short circuit and overload protection)
—1 electronic motor circuit protector with a Micrologic 2.2 M plus
—1 contactor
f The standard trip unit offers Class 5, 10 and 20 and phase unbalance or phase loss protection.

Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page DE3-33


Optional Lugs . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page DE3-36
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page DE3-45

11/18
08/21
DE3-30
Automatic Switches
Class 600 / Refer to Catalogs 0611CT1603, 0611CT1001, 0612CT0101

Automatic molded case switches open instantaneously at a factory preset magnetic trip point, calibrated to protect only
the molded case switch itself, when it is subjected to high fault currents. The trip point is nonadjustable and provides no
overload or low level fault protection.

Molded case switches open when the handle is switched to the OFF position or in response to an auxiliary tripping
device such as a shunt trip.
All molded case switches will accept the same lugs and accessories as equivalent thermal-magnetic circuit breakers,
with the exception of Q-frame switches which do not have electrical accessories available.
Automatic molded case switches are UL Listed per UL 489 and are CSA Certified.
J-Frame L-Frame
Switch Switch

B-Frame PowerPact™ Automatic Molded Case Switches, 600/347 Vac

Circuit Ampere D Withstand G Withstand J Withstand


Breaker Poles Rating Terminal Wire Range
Cat. No. Trip Point Cat. No. Trip Point Cat. No. Trip Point
2a 125 A BDL26000S12 1625 A BGL26000S12 1625 A BJL26000S12 1625 A LV426973 14–2/0 AWG Cu
B-Frame
3 125 A BDL36000S12 1625 A BGL36000S12 1625 A BJL36000S12 1625 A LV426974 14–2/0 AWG Cu

CIRCUIT BREAKERS
H-Frame, J-Frame, and L-Frame PowerPact™ Automatic Molded Case Switches, 600 Vac
Circuit Ampere G Withstand L Withstand R Withstand
Poles Terminal Wire Range
Breaker Rating Cat. No. Trip Point Cat. No. Trip Point Cat. No. Trip Point
150 A HGL26000S15a 2250A HLL26000S15 2250 A — — AL150HD 14 AWG–3/0 AWG Al/Cu
2 175 A JGL26000S17 3125 A JLL26000S17 3125 A — — AL175JD 4–4/0 AWG Al/Cu
H- and J- 250 A JGL26000S25 3125 A JLL26000S25 3125 A — — AL250JD 3/0 AWG–350 kcmil Al/Cu
Frame 150 A HGL36000S15 2250 A HLL36000S15 2250 A — — AL150HD 14 AWG–3/0 AWG Al/Cu
3 175 A JGL36000S17 3125 A JLL36000S17 3125 A JRL36000S17 3125 A AL175JD 4–4/0 AWG Al/Cu
250 A JGL36000S25 3125 A JLL36000S25 3125 A JRL36000S25 3125 A AL250JD 3/0 AWG–350 kcmil Al/Cu

DE3
400 A LGL36000S40X 4800 A LLL36000S40X 4800 A LRL36000S40X 4800 A AL600LS52K3
3 (2) 2/0 AWG–500 kcmil Al/Cu
600 A LGL36000S60X 6600A LLL36000S60X 6600 A LRL36000S60X 6600 A AL600LS52K3
L-Frame
400 A LGL46000S40X 4800 A LLL46000S40X 4800 A LRL46000S40X 4800 A AL600LS52K4
4 (2) 2/0 AWG–500 kcmil Al/Cu
600 A LGL46000S60X 6600A LLL46000S60X 6600 A LRL46000S60X 6600 A AL600LS52K4
a True 2P device. Others are a 2P in a 3P module.

Q-Frame (240 Vac) PowerPact™ Automatic Molded Case Switches


J Withstand
Circuit Ampere
Breaker Poles Rating Wire Range
Cat. No. Trip Point
2 225 A QBL22000S22 4500 A
Q-Frameb 4 AWG–300 kcmil
3 225 A QBL32000S22 4500 A
b Withstand rating of 10 kA at 240 Vac.

P-Frame and R-Frame PowerPact™ Automatic Molded Case Switchesd, 600 Vac
Ampere J Withstand K Withstand L Withstand
Frame Poles Rating Terminal Wire Range
Cat. No. Trip Point Cat. No. Trip Point Cat. No. Trip Point
600 A PJL26000S60 10 kA PKL26000S60 24 kA PLL24000S60c 10 kA (3) 3/0 AWG–500 kcmil
AL800M23K
800 A PJL26000S80 10 kA PKL26000S80 24 kA PLL24000S80c 10 kA Al or Cu
2
1000 A PJL26000S10 10 kA PKL26000S10 24 kA PLL24000S10c 10 kA (4) 3/0 AWG–500 kcmil
AL1200P25K
1200 A PJL26000S12 10 kA PKL26000S12 24 kA PLL24000S12c 10 kA Al or Cu
P
600 A PJL36000S60 10 kA PKL36000S60 24 kA PLL34000S60c 10 kA (3) 3/0 AWG–500 kcmil
AL800M23K
800 A PJL36000S80 10 kA PKL36000S80 24 kA PLL34000S80c 10 kA Al or Cu
3
1000 A PJL36000S10 10 kA PKL36000S10 24 kA PLL34000S10c 10 kA (4) 3/0 AWG–500 kcmil
AL1200P25K
1200 A PJL36000S12 10 kA PKL36000S12 24 kA PLL34000S12c 10 kA Al or Cu
1200 A — — RKF26000S12 57 kA RLF26000S12 48 kA
1600 A — — RKF26000S16 57 kA RLF26000S16 48 kA
2
2000 A — — RKF26000S20 57 kA RLF26000S20 48 kA R-frame circuit breakers can be
2500 A — — RKF26000S25 57 kA RLF26000S25 48 kA bus-connected or cable-connected.
R 1200 A — — RKF36000S12 57 kA RLF36000S12 48 kA For cable connections, RLTB kit or
equivalent bus structure is required.
1600 A — — RKF36000S16 57 kA RLF36000S16 48 kA Kit is included with 3000 A switches.
3 2000 A — — RKF36000S20 57 kA RLF36000S20 48 kA For all others, see page DE3-43.
2500 A — — RKF36000S25 57 kA RLF36000S25 48 kA
3000 A — — RKF36000S30 57 kA RLF36000S30 48 kA
c P-frame L-interrupting is available in 480 Vac only.
d UL magnetic trip tolerances are -20% / +30% from the nominal values shown.

B-**, H-, J-, L- P-, and R-Frame Withstand Ratingse


Withstand
Voltage
D G J K L R
240 Vac 25 kA 65 kA 100 kA 65 kA 125 kA 200 kA
480 Vac 18 kA 35 kA 65 kA 50 kA * 100 kA 200 kA
600 Vac 14 kA 18 kA 25 kA 50 kA * 50 kA 100 kA
e The withstand rating is the fault current at rated voltage that the molded case switch will withstand without damage when protected by a circuit breaker
with an equal continuous current rating.
* R-Frame withstand rating is 65kA
**‘ B-Frame withstand rating at 600Y/347Vac

Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page DE3-33


Optional Lugs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page DE3-36
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Pages DE3-44 and DE3-45
Enclosures. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Pages DE3-46–DE3-49

11/18
08/21
DE3-31
500 Vdc Circuit Breakers
CSA/UL Listed 500 Vdc Circuit Breakers Class 500, 600 / Refer to Catalog 0611CT1001

The CSA/UL Listed thermal-magnetic molded case circuit breakers shown below are
specifically designed for use on ungrounded dc systems having a maximum short-circuit
voltage of 500 Vdc or a maximum floating (unloaded) voltage of 600 Vdc. The circuit
breakers are suitable for use only with UPS (uninterruptable power supplies).
This two-level voltage rating allows these circuit breakers to be applied to battery sources
having a short-circuit availability of 20,000 amperes or 50,000 amperes for PowerPact H-,
J-, and L-Frame DC circuit breakers at 500 Vdc.
PowerPact H-frame DC circuit breakers have a fixed magnetic trip system. PowerPact J-
and L-frame DC circuit breakers are provided with an adjustable magnetic trip that is readily
accessible by means of a single adjustment on the face of the circuit breaker.

PowerPact H- and J-frame circuit breakers are CSA/UL Listed for the interrupting ratings
shown only if applied with three poles connected in series (series connection is external to
circuit breaker). (See figure for example of diagram.)

PowerPact L-frame circuit breakers are CSA/UL Listed for the interrupting ratings shown
with two or three poles connected in series (series connection is external to circuit breaker).
CIRCUIT BREAKERS

NOTE: Due to external series connection, I-Line™ circuit breakers are not available for
this application.

DC Molded Case Circuit Breakers


Adjustable Magnetic Trip Interrupting
Circuit Breaker Fixed Magnetic Range—DC Amperesa
Ampere Rating Cat. No. Trip —DC Amperes Rating
Low High @ 500 Vdc
30 A HGL37030D87 450 — —
Connection Diagram 50 A HGL37050D87 450 — — 20 k AIR
DE3

70 A HGL37070D87 450 — —
Termination Options 100 A JGL37100D81 — 400 600
125 A JGL37125D81 — 400 600
Termination Letter Termination Option
150 A JGL37150D81 — 400 600
L Lugs Both Ends 20 k AIR
175 A JGL37175D81 — 400 600
F No Lugs (bus bar connection) 200 A JGL37200D82 — 500 850
S Rear Connection 225 A JGL37225D82 — 500 850
JGL37125D81 - Place termination letter in third block of circuit breaker 250 A JGL37250D82 — 500 850 20 k AIR
catalog number
300 A LGL37030D27 — 750 1500
350 A LGL37035D29 — 875 1750
400 A LGL37040D30 — 1000 2000
450 A LGL37045D31 — 1125 2250
500 A LGL37050D32 — 1250 2500
600 A LGL37060D33 — 1500 3000 20 k AIR
700 A LGL47070D35 — 1750 3500
800 A LGL47080D36 — 2000 4000
900 A LGL47090D86 — 2250 4500
1000 A LGL47100D40 — 2500 5000
1200 A LGL47120D42 — 3000 6000
30 A HLL37030D87 450 — —
50 A HLL37050D7 450 — — 50 k AIR
70 A HLL37070D87 450 — —
100 A JLL37100D81 — 400 600
125 A JLL37125D81 — 400 600
150 A JLL37150D81 — 400 600
175 A JLL37175D81 — 400 600 50 k AIR
200 A JLL37200D82 — 500 850
225 A JLL37225D82 — 500 850
250 A JLL37250D82 — 500 850
300 A LLL37030D27 — 750 1500
350 A LLL37035D29 — 875 1750
400 A LLL37040D30 — 1000 2000
450 A LLL37045D31 — 1125 2250
500 A LLL37050D32 — 1250 2500
600 A LLL37060D33 — 1500 3000 50 k AIR
700 A LLL47070D35 — 1750 3500
800 A LLL47080D36 — 2000 4000
900 A LLL47090D86 — 2250 4500
1000 A LLL47100D40 — 2500 5000
1200 A LLL47120D42 — 3000 6000
a Magnetic trip tolerances are -20%/+30% from the nominal values shown.

Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page DE3-33


Optional Lugs . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page DE3-36
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page DE3-45
Enclosures. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page DE3-48

11/18
01/20
08/21
DE3-32
PowerPact™ Circuit Breaker Accessories
Class 0611, 612 / Refer to Catalogs 0611CT1603, 0611CT1001, 0612CT0101 Electrical Accessories

Electrical Accessories
B-, H-, J-, and L-Frame M-, P-, and R-Frame
B-Frame H- and J-Frame L-Frame
Factory- Factory Field-
Accessory Description Rated Voltage Installed Field- Field-
Installed Installable
Cat. Installable Installable Field-Installable Field-Installable
Cat. Suffix Cat. No.
Suffix Cat. No. Pre-Wired Cat. No. Cat. No.
Cat. No.
Auxiliary and 1 auxiliary switch (OF) 1a1b AA LV426950 LV426951 S29450 S29450 AA S29450
Alarm Switches 2 auxiliary switch (OF) 2a2b AB — — 2x S29450 2x S29450 AB 2x S29450
(OF, SD, SDE) 3 auxiliary switch (OF) 3a3b AC — — — 3x S29450 AC 3x S29450
Alarm Switch (SD) 1a1b BC LV426950 LV426952 S29450 S29450 BC S29450
Standard Overcurrent trip switch (SDE) 1a1b BD — — — S29450 BD S29450
Min OF Switch — — — S29450 — — —
Load = Consisting of:
10mA with SDE Adapter — — — S29451 — — —
Provides circuit 24V Alarm switch and Overcurrent trip switch BE — — — 2x S29450 BE 2x S29450
breaker contact OF Switch — — — 2x S29450 — — —
status. Consisting of:
SDE Adapter — — — S29451 — — —
Note: The Auxiliary Switch/Alarm Switch/Adapter — — — — — — S33801b
location of the (OF/SD/SDE) Kit
accessory in the One auxiliary switch (OF) 1a1b AE — — S29452 S29452 AE S29452
circuit breaker
CIRCUIT BREAKERS

CIRCUIT BREAKERS
determines its Two auxiliary switches (OF) 2a2b AF — — 2x S29452 2x S29452 AF 2x S29452
function. 3 auxiliary switches (OF) 3a3b AG — — — 3x S29452 AG 3x S29452
Low Level Alarm Switch (SD) 1a1b BH — — S29452 S29452 BH S29452
Min Overcurrent trip switch (SDE) 1a1b BJ — — — S29452 BJ S29452
Load =
1mA with OF Switch — — — S29452 — — —
Consisting of:
24V SDE Adapter — — — S29451 — — —
Alarm switch and Overcurrent trip switch BK — — — 2x S29452 BK 2x S29452
H-, J-, L-, M-, P, and OF Switch — — — 2x S29452 — — —
R-Frame Consisting of:
SDE Adapterc — — — S29451 — — —
Shunt Trip (MX) 24 SK LV426841 LV426861 S29384 S29384 SK S33659

DE3
DE3

48 SL LV426842 LV426862 S29385 S29385 SL S33660


110-130 SA LV426843 LV426863 S29386 S29386 SA S33661
AC 220-240 — — — — — SC S33662
208-277 SD LV426844 LV426864 S29387 S29387 SD S33663
380-480 SH LV426846 LV426866 S29388 S29388 SH S33664
B-Frame Trips the circuit breaker from a
remote location by means of a 525-600 SJ — — S29389 S29389 — —
trip coil energized from a 12 SN — — S29382 S29382 SN S33658
separate supply voltage 24 SO LV426841 LV426861 S29390 S29390 SK S33659
circuit.
30 SU — — S29391 S29391 SK S33659
48 SP LV426842 LV426862 S29392 S29392 SL S33660
DC
60 SV — — S29383 S29383 SL S33660
125 SR LV426843 LV426863 S29393 S29393 SA S33661

H-, J-, and L-Frame 250 SS LV426844 LV426864 S29394 S29394 SC S33662
24 UK LV426801 LV426821 S29404 S29404 UK S33668
Undervoltage Trip 48 UL LV426802 LV426822 S29405 S29405 UL S33669
(MN) 110-130 UA LV426803 LV426823 S29406 S29406 UA S33670
220-240 — LV426804 LV426824 — — UC S33671
Instantaneously opens the AC
208-277 UD LV426805 LV426825 S29407 S29407 — —
circuit breaker when the
under-voltage trip supply 380-415 UF LV426806 LV426826 — — — —
voltage drops to a value 380-480 UH LV426807 LV426827 S29408 S29408 UH S33673
between 35% and 70% of its 525-600 UJ — — S29409 S29409
rated voltage. Closing is — —
allowed when the supply 12 UN — — S29402 S29402 — —
voltage of the undervoltage 24 UO LV426801 LV426821 S29410 S29410 UK S33668
trip reaches 85% of rated 30 UU — — S29411 S29411 UK S33668
voltage.
DC 48 UP LV426802 LV426822 S29412 S29412 UL S33669
H-, J-, and 60 UV — — S29403 S29403 UL S33669
L-Frame
125 UR LV426803 LV426823 S29413 S29413 UA S33670
250 US LV426815 LV426835 S29414 S29414 UC S33671
Undervoltage trip with 48 — S33680a — S33680a S33680a — S33680a
Time Delay Unit externally mounted 100-130 — S33681a — S33681a S33681a — S33681a
adjustable time delay unit for
UVR of 0.5, 0.9, 1.5, 3.0 AC/DC 220-250 — S33682a — S33682a S33682a — S33682a
seconds before circuit 380-480 — — — — — — S33683a
breaker trips
48 — S29426a — S29426a S29426a — —
Undervoltage trip with
externally mounted non- 100-130 — — — — — — S33684a
adjustable time delay unit of AC/DC
0.25 sec before circuit breaker 200-250 — — — — — — S33685a
trips.
220-240 — S29427a — S29427a S29427a — —
a Field-installable kit includes time delay module only. Order undervoltage trip separately.
b P-frame drawout circuit breaker only.
c SDE Adapter used for H- and J-frame only.
d Not available on electrically operated P-frame.

11/18
DE3-33
01/20
08/21
PowerPact™ Circuit Breaker Accessories
Motor Operators and Rotary Handles Class 0611, 612 / Refer to Catalogs 0611CT1001, 0612CT0101
Motor Operators for H-, J-, and L-Frame Circuit Breakers
Field--Installable Kit
Factory
Description Rated Voltage Installed H-Framea J-Frame L-Frame 600 A
Cat. No. Suffix
Cat. No. Cat. No. Cat. No.
48-60 ML S29440 S31548 S432639
110-130 MA S29433 S31540 S432640
208-277
AC 220-240 MD S29434 S31541 S432641

Standard motor for electrically-operated circuit 380-415 MF — — S432642


breakersb 440-480 MH S29435 S31542 S432647
24-30 MO S29436 S31543 S432643
48-60 MV S29437 S31544 S432644
DC
110-130 MR S29438 S31545 S432645
250 MS S29439 S31546 S432646
Communicating motor for electrically-operated AC 220-240 NC S429441 S431549 S432652
Motor Operator circuit breakersc
Mounting hardware — — — S32649
Locking device Ronis lock — S41940 S41940 S41940
Profalux lock — S42888 S42888 S42888
Mounting hardware plus Ronis
— S429449 S429449 —
lock
Operations counter — — — S32648
CIRCUIT BREAKERS

Adapter for I-Line circuit breaker — S37420 S37420 —


Spring-Charging Motors for Electrically-Operated P-Frame Circuit Breakers
Factory Installed P-Frame (For Field-replacement Only) Replacement Coils
Description Rated Voltage
Cat. No. Suffix Spring Charging Motor Cat. No. Opening/Closing Coil Cat. No.
48 ML S47391 S33660
100-130 MA S47395 S33661
AC
220-240 MC S47396 S33662
Standard motor for electrically-
operated circuit breakers. 380-415 MF S47398 S33664
Factory-installed includes motor and 24-30 MO S47390 S33659
DE3

opening/closing coils. 48-60 MV S47391 S33660


DC
110-130 MR S47392 S33661
200-250 MS S47393 S33662
48 NL S47391 S33034
100-130 NA S47395 S33035
AC
220-240 NC S47396 S33036
Communicating motor mechanism for
Spring-charging electrically operated circuit breakers. 380-415 NF S47398 S33038
Factory-installed includes motor 24-30 NO S47390 S33033
Motor and opening/closing coils. 48-60 NV S47391 S33034
DC
110-130 NR S47392 S33035
200-250 NS S47393 S33036
Rotary Operated Handles
B-Frame H- and J-Framea L-Frame P-Frame
Factory Field Factory Field Factory Field Factory
Device Description Installed Installable Installed Installable Installed nstallable Installed
Cat. No. Cat. No. Cat. No. Cat. No.
Suffix Cat. No. Suffix Cat. No. Suffix Cat. No. Suffix
Standard black handle Operating mechanism kit RD10 LV426930 RD10 S29337 RD10 S32597 RD10
Two early-break and two early make switches — — — — — — RD16
Standard black handle with One early-break switch — — RD12 S29337 +S29345 RD12 S32597 +S32605 —
Two early-make switches — — RD13 S29337 +S29346 RD13 S32597 +S29346 —
Direct Mounted Operating mechanism kit RD20 LV426931 RD20 S29339 RD20 S32599 —
Red handle on yellow bezel One early-break switch — — RD22 S29339 +S29345 RD22 S32599 +S32605 —
Two early-make switches — — RD23 S29339 +S29346 RD23 S32599 +S29346 —
MCC conversion accessory — — S429341 — S32606 —
CNOMO conversion accessory — — — — — S32602 —
Standard black handle Operating mechanism kit — LV426932 RE10 S29338 RE10 S32598 RE10
Standard black handle Two early-break and two early make switches — — — — — — RE16
Door Mounted with:
Two early make switches — RE13 S29338 +S29346 RE13 S32598 +S29346 —
Red handle on yellow bezel Operating mechanism kit — LV426933 RE20 S29340 RE20 S32600 —
Rotary Handle Replacement Kit — — — — — — S33875
Telescoping — — RT10 S29343 RT10 S32603 —
Key lock adapter — — — S429344 — S32604 —
Ronis 1351.500 — — — S41940 — S41940 —
Profalux KS5 B24 D4Z — — — S42888 — S42888 —
Key locks
Accessories 2 Ronis keylocks with 1 key — — — S41950 — S41950 —
2 Profalux keylocks with 1 key — — — S42878 — S42878 —
One early-break switch — — — S29445 — S32605 —
Indication Auxiliary Switch
Two early-make switches — — — S29346 — S29346 —
a Not available in H-frame 2P modules.
b Factory and field-installed standard motor operators for H- and J-frame circuit breakers
require the SDE switch and SDE adapter (both included).
Factory and field-installed standard motor operators for L-frame circuit breakers require the
SDE switch (included).
c Installation requires BSCM with NSX Cord. See page DE3-43 for ordering information.

Direct-Mounted Door-Mounted
handle Handle

11/18
DE3-34
01/20
08/21
Class 0611, 612 / PowerPact™ Circuit Breaker Accessories
Refer to Catalogs 0611CT1001, 0612CT0101 Locks, Installation Accessories, and Rear Connections
Locks, Interlocking
B-Frame H- and J-Frame Q-Frame L-Frame M- and P-Frame R-Frame
Factory Field- Factory Field- Factory Field- Factory Field- Factory Field- Factory Field-
Device Description Installed Installed Installed Installed Installed Installed Installed
Installed Installed Installed Installed Installed
Cat. No. Cat. No. Cat. No. Cat. No. Cat. No. Cat. No.
Suffix Cat. No. Suffix Cat. No. Suffix Cat. No. Suffix Cat. No. Suffix Cat. No. Suffix Cat. No.
Removable (lock OFF only) — S29370 — S29370 — — S29370 — S44936 — S33996
LV426905
Fixed (lock OFF or ON) YP LV426907 YP S29371a YP QBPA YP S32631 YP S32631 YP S32631
Handle (I-Line)
Padlocking
Device Fixed (lock OFF only)-2P — — YQ H2PHLA YQ — — — — — — —
LV426906
Fixed (lock OFF only)a YQ YQ S37422 YQ QBPAF YQ NJPAF YQ MPRPAF YQ MPRPAF
(I-Line)
Mechanical for circuit breakers with rotary — — — S29369 — — — S32621 — S33890 — —
Interlocking handlesa
(Not UL listed)
Mechanical for circuit breakers with togglesa — LV426909 — S29354 — QBMIK — S32614 — — — —
Provision only, vertical mount,
1 or 2 locks Kirk — — — — — — — — JA — —
Provisions only, vertical mounting
one key interlock including padlock Kirk — — — — — — — — JEac — JEc —
provision, open position only.
Provision only, horizontal mount Kirk — — — — — — — — JK — JK —
1 lock, M- and P-frame Ronis — — — — — — — — JBd — JB —
1 or 2 locks, R-frame Profalux — — — — — — — — JDd — JD —
CIRCUIT BREAKERS

CIRCUIT BREAKERS
Provision and 1 lock, vertical Kirk — — — — — — — — JG — — —
mount
Key Locking Kirk — — — — — — — — JL — JL —
Provision and 1 lock, horizontal Ronis — — — — — — — — JCd — JC —
mount
Profalux — — — — — — — — JFd — JF —
Provision and 2 locks keyed alike Kirk — — — — — — — — JN — JN —
Provision and 2 locks keyed Kirk — — — — — — — — JP — JP —
differently
a Not available in M frame or HD and HG 2P modules.
d Not available for M, P.

DE3
DE3

c Not available on I-Line.

Installation Accessories for B-, H-, J-, and L-Frame Circuit Breakers
Field- Installed Cat. No.
Description H- and J-
B-Frame L-Frame
Frame
Front Panel Escutcheon for Toggle Breakers — S29315 32556
Front Panel Escutcheon for Rotary Handle, Motor Operator, or extended escutcheon — S29317 S32558
Phase Barriers (set of 6) LV426920 S29329 32570
Handle Rubber Boot Door Escutcheon Handle Rubber Bootd — S29319 S32560
Sealing Accessories (for front cover screws) S29375 S29375 S29375
DIN rail mounting kit (requires 15 mm depth on a 35 mm DIN rail)d Standard S29305 —
DIN rail adapter Standard — —
Handle Extensions (set of 5) — S29313 S432553
Rear Insulation Kit (2P) LV426921 — —
Rear Insulation Kit (3P) LV426922 — —
Rear Insulation Kit (4P) LV426923 — —
Terminal Extentions-Spreaders (3P) LV426940 — —
Terminal Extentions-Spreaders (4P) LV426941 — —
5 N-m Torque Limiting Bit, Set of 6 LV426992 — —
Terminal Covers 5 N-m Torque Limiting Bit, Set of 8 LV426993 — —
Rear Connection 9 N-m Torque Limiting Bit, Set of 6 LV426990 — —
9 N-m Torque Limiting Bit, Set of 8 LV426991 — —
d Not available in HD and HG 2P modules.
Installation Accessories for M-, P-, and R-Frame Circuit Breakers
Field-Installed
Description Frame Cat. No.
M-, P-Frame S33718
Accessory Cover
R-Frame S33929
Door Escutcheon
Toggle Handle M-, P-Frame S33717
Drawout P-Frame S33857
Short lug cover 3P S33932
Removable Padlock Fixed Padlock Short lug cover 4P S33933
Attachment Attachment Terminal Covers
Long lug cover 3P
P-Frame
S33934
Long lug cover 4P S33935
Standard R-Frame S33997
Replacement Handle Standard Short M-, P-Frame S46998
Long M-, P-Frame S46996

Rear Connections
H-Frame J-Frame L-Frame
Device Description Factory-
Poles Installed Field-Installable Poles Factory-Installed Field-Installed Poles Factory-Installed Field-Installed
Termination No. Cat. No. Termination No. Cat. No. Termination No. Cat. No.

Mixed Rear 2 S — 2 S — 3 S S32477


Connection Kite 3 S S37432 3 S S37437 4 S S32478
Short rear connections (set of 2) — 2x S37433 — 2x S37438 — 2x S432475
2 or 3 2 or 3 3
Long rear connections (set of 2) — S37434 — S37439f — 2x S432476
Consisting of:
Short terminal cover (3P) 3 — S37436 3 — S37440 3 — 2x S32562
Short terminal cover (4P) 4 — — — — — 4 — 2x S32563
e Kit contains 4 short rear connections, 2 long rear connections (4 long rear connections for 4P), hardware, and 2 terminal covers..
f For use with 3P circuit breakers only.

11/18
01/20
08/21
DE3-35
PowerPact™ Circuit Breaker Accessories
Mechanical Lugs Class 0611, 612 / Refer to Catalogs 0611CT1603, 0611CT1001, 0612CT0101

Mechanical Lug Kits for B-Frame Circuit Breakersa


Circuit Breaker Application Factory- Field-
Description Ampere Number of Wires Installed Cat. Installable Qty
Standard Ampere Rating Optional Rating Per Lug and Wire Range Suffix Cat. No. Per Kit

Al Lugs for Use with Al or BD BG BJ 15 - 125 A (1) 14-2/0 AWG AI or Cu LH LV426966 2


Cu Wire BD BG BJ 15 - 125 A (1) 14-2/0 AWG AI or Cu LH LV426967 3
Cu Lugs for Use with Cu BD BG BJ 15 - 125 A (1) 14-1/0 AWG Cu LC LV426964 2
Wire Only BD BG BJ 15 - 125 A (1) 14-1/0 AWG Cu LC LV426965 3
BD BG BJ (1P) 15 - 125 A (1) 14-2/0 AWG Cu — LV426972 1
BD BG BJ (2P) 15 - 125 A (1) 14-2/0 AWG Cu — — —
J-Frame Lug EverLink Lug
BD BG BJ (3P) 15 - 125 A (1) 14-2/0 AWG Cu — — —
BD BG BJ (4P) 15 - 125 A (1) 14-2/0 AWG Cu — — —
15 - 125 A BD BG BJ (2P) (1) 14-2/0 AWG Cu LU, LV or LWh LV426973 1
EverLink Lug with 15 - 125 A BD BG BJ (3P) (1) 14-2/0 AWG Cu LU, LV or LWh LV426974 1
Control Wire Tap
15 - 125 A BD BG BJ (4P) (1) 14-2/0 AWG Cu LU, LV or LWh LV426975 1

Mechanical Lug Kits for H-Frame and J-Frame Circuit Breakersa


Circuit Breaker Application Ampere Number of Wires Qty
Description Kit Cat. No.
Standard Ampere Rating Optional Rating Per Lug and Wire Range Per Kit
HD, HG, HJ, HL 15–150 A (1) 14–3/0 AWG Al or Cu AL150HD 3

CIRCUIT BREAKERS
Al Lugs for Use with Al or
CIRCUIT BREAKERS

Cu Wire JD, JG, JJ, JL 150–175 A (1) 4-4/0 AWG Al or Cu AL175JD 3


JD, JG, JJ, JL 200–250 A JD,JG,JJ,JL 150–175 A (1) 3/0–350 kcmil Al or Cu AL250JD 3
Cu Lugs for Use with Cu HD,HG,HJ,HL 15–150 A (1) 14–2/0 AWG Cu CU150HD 3
Wire Only JD,JG,JJ,JL 150–250 A (1) 1/0–300 kcmil Cu CU250JD 3
Control Wire Terminal for H-frame lug kit S37423 2
Control Wire Terminal for J-frame lug kit S37424 2
a See page DE3-38 for terminal nuts/bus bar connections.

Mechanical Lug Kits for L-Frame Circuit Breakers


DE3

DE3
Circuit Breaker Application
Description Number of Wires Kit Cat. No. Qty
Ampere Per Lug and Wire Range Per Kit
Poles Unit Mount I-Line
Rating
250 3 X X (1) 2 AWG–500 kcmil Al AL400L61K3 3
4 X — (1) 2 AWG–600 kcmil Cu AL400L61K4 4
Al Lugs for Use with Al 400/600 3 X — AL600LS52K3 3
or Cu Wire (2) 2/0 AWG–500 kcmil Al or Cu
4 X — AL600LS52K4 4
L-Frame Lugs
400/600 3 X X (2) 3/0 AWG–500 kcmil Al or Cu AL600LF52K3 3
250/400 3 X X CU400L61K3 3
(1) 2 AWG–600 kcmil Cu
4 X — CU400L61K4 4
Cu Lugs for Use with Cu
400/600 3 X — CU600LS52K3 3
Wire Only (2) 2/0 AWG–500 kcmil Cu
4 X — CU600LS52K4 4
400/600 3 X X (2) 3/0 AWG–500 kcmil Cu CU600LF52K3 3

Mechanical Lug Kits for M-Frame, P-Frame and R-Frame Circuit Breakerse
Circuit Breaker Application
Wires per Lug Lugs
Description Ampere and Wire Range Cat. No. Per Kit
Standard Rating Optional Rating
AL800M23K 3
800 A — 800 A (3) 3/0 AWG-500 kcmil
AL800M23K4 4
M- and P-Frame Lugs
1200 A PG, PJ, PL, PK, MG, MJ 800 A (4) 3/0 AWG-500 kcmil AL1200P24Kb 1
(800 A and below)
M-, P-Frame AL800P6Kb 3
— PG, PJ, PL, PK, MG, MJ 800 A (2) 3/0 AWG-600 kcmil
AL800P6K4b 4
(2) 3/0 AWG-750 kcmil AL800P7Kb 3
— PG, PJ, PL, PK, MG, MJ 800 A 750 kcmil: compact AL only AL800P7K4b 4
Al Lugs AL1200P25Kc 3
for AL or Cu Wire 1200 A PG ,PJ, PL, PK 800 A (4) 3/0 AWG-500 kcmil
AL1200P25K4c 4
P-Frame
AL1200P6KUc 3
— PG, PJ,P L, PK 800–1200 A (3) 350-600 kcmil
AL1200P6KU4c 4
(3) 3/0 AWG-750 kcmil AL1200P7KUc 3
PG,PJ,PL — PG, PJ, PL, PK 1200 A
750 kcmil: compact AL only AL1200P7KU4c 4
1200 A I-Line — (4) 3/0 AWG-600 kcmil AL1200R53K 1
R-Frame
2500 A Unit Mount — (1) 3/0 AWG-750 kcmil AL2500RKd 2
— PJ 100–150 A (1) 1-1/0 AWG CU250P1Kf 3
CU800M23K 3
M-, P-Frame 800 A MG, MJ, PG, PJ, PL, PK — (3) 3/0 AWG-500 kcmil
CU800M23K4 4
Cu Lugs 1200 A MG, MJ, PG, PJ, PL, PK 800–1200 A (4) 3/0 AWG-500 kcmil CU1200P24Kb 1
for Cu Wire Onlyd
P-Frame Lugs CU1200P25Kc 3
P-Frame 1200 A PG, PJ, PL, PK 800–1200 A (4) 3/0 AWG-500 kcmil
(Above 800 A) CU1200P25K4 4
R-Frame 1200 A I-Line — (4) 3/0 AWG-500 kcmil CU1200R53K 1
b Does not fit onto ON end of unit-mount P-frame circuit breakers.
c For unit-mount circuit breaker only.
d All unit-mount R-frame circuit breakers require terminal pads for mounting lugs of any type. See page DE3-43.
e For lug with a tapped hole for control wire, add a “T” before the “K” in the catalog number (for example, AL800P6TK).
f This lug can only be used on low amp PJ frame breakers where the Instantaneous setting must not be turned OFF. The cables must be laced with rope
per lug instructions.
g Not available with tapped hole for control wire.
h LU = ON end only, LV = OFF end only, LW = BOTH ends

11/18
01/20
08/21
DE3-36
Class 0611, 612 / Refer to Catalogs PowerPact™ Circuit Breaker Accessories
0611CT1001, 0612CT0101 Compression Lugs and Power Distribution Connectors (PDC)
Compression Lug Kits for PowerPact™ Circuit Breakers
Circuit Ampere Mounting Dimension A Max. Lugs per Qty.
Description Breaker Type Rating System Range Type (in) Terminal Cat. No. Per Kit
Compression Lug Kits for B-Frame Circuit Breakers
Aluminum 125 A 8–1/0 AWG Al or Cu 1.3 1 LV426988 2
Compression B-frame
Lug Kits 125 A 8–1/0 AWG Al or Cu 1.3 1 LV426989 3
Unit
Copper 125 A 6–1/0 AWG Cu 1.4 1 LV426986 2
Compression B-frame
Lug Kits 125 A 6–1/0 AWG Cu 1.4 1 LV426987 3
Compression Lug Kits for H-Frame and J-Frame Circuit Breakers
60 A 6–2 AWG Al or Cu 1.2 1 YA060HD 3
Aluminum H-frame
150 A 1/0–4/0 AWG Al or Cu 2.5 1 YA150HD 3
Compression
Lug Kits 150 A 1–3/0 AWG Al or Cu 1.2 1 YA150JD 3
J-frame
250 A 3/0–350 kcmil Al or Cu 2.5 1 YA250J35 3
Unit
60 A 6–1/0 AWG Cu 1.0 1 CYA060HD 3
Copper H-frame
150 A 4–2/0 AWG Cu 1.2 1 CYA150HD 3
Compression
Lug Kits 150 A 6–1/0 AWG Cu 0.7 1 CYA150JD 3
J-frame
250 A 2/0–300 kcmil Cu 1.1 1 CYA250J3 3
J-Frame Compression Lugs Compression Lug Kits for L-Frame Circuit Breakers
400 A 4-300 kcmil Al/Cu 1.2 1 YA400L31K3 3
600 A 4-300 kcmil Al/Cu 2.5 2 YA600L32K3 6

CIRCUIT BREAKERS
400 A 2/0-500 kcmil Al/Cu 1 YA400L51K3 3
600 A 2/0-500 kcmil Al/Cu 2 YA600L52K3 6
400 A 500-750 kcmil Al 1 YA400L71K3 3
Aluminum 500 kcmil Cu
Compression L-frame Unit
Lug Kits 400 A 4-300 kcmil Al/Cu 1 YA400L31K4 4
600 A 4-300 kcmil Al/Cu 2 YA600L32K4 8
400 A 2/0-500 kcmil Al/Cu 1 YA400L51K4 4
600 A 2/0-500 kcmil Al/Cu 1.2 2 YA600L52K4 8
400 A 500-750 kcmil Al 2.5 1 YA400L71K4 4
500 kcmil Cu
400 A 2/0-300 kcmil Cu 1.2 1 CYA400L31K3 3

DE3
600 A 2/0-300 kcmil Cu 2.5 2 CYA600L32K3 6
400 A 250-500 kcmil Cu 1 CYA400L51K3 3
Copper 600 A 250-500 kcmil Cu 2 CYA600L52K3 6
Compression L-frame Unit
Lug Kits 400 A 2/0-300 kcmil Cu 1 CYA400L31K4 4
600 A 2/0-300 kcmil Cu 2 CYA600L32K4 8
400 A 250-500 kcmil Cu 1 CYA400L51K4 4
600 A 250-500 kcmil Cu 2 CYA600L52K4 8
Compression Lug Kits for M-Frame, P-Frame, and R-Frame Circuit Breakers
250 A 2/0-300 kcmil 3.7 2 YA250P3 1
300 A 4/0-500 kcmil 3.9 2 YA300P5 1
400 A 2/0-300 kcmil 4.3 2 YA400P3 2
M-, P-framec Unit
400 A 500-750 kcmil 3.7 2 YA400P7 1
600 A 4/0-500 kcmil 3.9 2 YA600P5 2
Aluminum 800 A 500-750 kcmil 4.3 2 YA800P7 2
Compression
Lug Kits 1200 A 2/0-300 kcmil 3.8 4 YA1200R3 4
P-Frame Compression Lug Kit 1200 A 4/0-500 kcmil I-line 4.0 4 YA1200R5 4
1200 A 500-750 kcmil 4.4 4 YA1200R7 4
R-frameac
2000 A 2/0-300 kcmil a 8 YA2000R3 2
2000 A 4/0-500 kcmil Unit a 8 YA2000R5 2
2500 A 500-750 kcmil a 8b YA2500R7 2
400 A 4/0-500 kcmil 3.3 2 CYA400P5 1
Copper M-, P-framec 600 A 4/0-500 kcmil Unit 3.3 2 CYA600P5 2
Compression 800 A 500-750 kcmil 3.6 2 CYA800P7 2
Lug Kits 1200 A 4/0-500 kcmil 3.5 4 CYA1200R5 4
R-Frame Compression Lug Kit R-framec I-Line
1200 A 500-750 kcmil 3.8 4 CYA1200R7 4
a All unit-mount R-frame circuit breakers require terminal pads for mounting lugs of any type. See page DE3-43.
b 9 lugs for 3000 A circuit breakers
c Not for use on I-Line™ circuit breakers unless wire bending space is adequate.

Power Distribution Connectors for B-Frame, H-Frame, J-Frame and L-Frame Circuit Breakers
PDC6HD6 PDC6JD4
Use with Circuit Circuit Breaker Wires Per Terminal & Qty.
Ampere Rating Dimension A (in.) Cat. No. Per Kit
Breaker Type Wire Range
125 (3) 14–2 AWG 1.2 PDC3BD2 3
BD, BG, BJ
125 (6) 14–6 AWG 1 PDC6BD6 3
15–150 (6) 14–6 AWG Cu 1.0 PDC6HD6 3
HD, HG, HJ, HLd
15–150 (3) 14–2 AWG Cu 1.2 PDC3HD2 3
PDC12P4 PDC6P20 150–250 (6) 14–4 AWG Cu 1.0 PDC6JD4 3
JD, JG, JJ, JLd
Crimp lug or PDC connectors 150–250 (2) 14–1 AWG and (1) 3–2/0 AWG Cu 1.5 PDC3JD20 3
extension past end or circuit 150–600 (3) 14–1 AWG and (2) 3–2/0 AWG 1.28f PDC5DG20L3 3
LD, LG, LJ, LL
breaker “A” See Table 150–600 (12) 14–4 AWG 1.31f PDC12DG4L3 3
d OFF end only when OFF end is the load end.

Power Distribution Connectors for M-Frame and P-Frame Circuit Breakerse


Ampere Rating (Wires Per Terminal) Cat. No. Qty Per Kit
Extremity Use for multiple load connections on one circuit breaker in place of standard Wire Range
of distribution block to save space and time.
Molded Case • Use on load end of circuit breaker only (6) 12–2/0 AWG Cu PDC6P20 3
• Use in UL508 Industrial Control applications only. 250–1200 A
w/Mechanical (6) 12–2/0 AWG Cu PDC6P204 4
Lugs • Use in UL1995/CSA C22.2 No. 236 heating and cooling equipment. PDC12P4 3
• For Cu wire only. 250–1200 A (12) 10–4 AWG Cu
PDC12P44 4
e Not for use with I-Line™ circuit breakers.
f Kit includes long terminal shield and cover, which adds 1.65 inches to standard lug with short terminal shield.
“A” See Table

11/18
01/20
08/21
DE3-37
PowerPact™ Circuit Breaker Accessories Class 0611, 612 / Refer to Catalogs
Terminal Nuts, Terminal Pads, Terminal Shields and Accessories 0611CT1001, 0612CT0101

Terminal Nuts for Bus Bar Connection of B, H and J-Frame Circuit Breakers
Description Frame Tap Cat. No. Qty Per Kit
B-FrameTerminal Nut Insert-Metric BD/BG/BJ (2P) M6 LV426962 2
B-FrameTerminal Nut Insert-Metric BD/BG/BJ (3P) M6 LV426963 3
H-Frame Terminal Nut Insert–English HD/HG/HJ/HL 1/4-20 S37425 2
H-Frame Terminal Nut Insert–English HD/HG/HJ/HL 1/4-20 S37444 3
Terminal Nut Insert H-Frame Terminal Nut Insert–Metric HD/HG/HJ/HL M6 S37426 2
J-Frame Terminal Nut Insert–English JD/JG/JJ/JL 1/4-20 S37427 2
J-Frame Terminal Nut Insert–English JD/JG/JJ/JL 1/4-20 S37445 3
J-Frame Terminal Nut Insert–Metric JD/JG/JJ/JL M8 S37428 2
Control Wire Terminal for H-Frame Terminal Nut HD/HG/HJ/HL S37429 2
Control Wire Terminal for J-Frame Terminal Nut JD/JG/JJ/JL S37430 2

H-Frame Lug With Bus Bar Connections Hardware for L-Frame, M-Frame and P-Frame Circuit Breakers
Terminal Nut
Frame Description Term. No. Poles Cat. No.

CIRCUIT BREAKERS
CIRCUIT BREAKERS

L-Frame Set of 4 terminal screws and washers for one side F 4 S36967
M- and P-Frame Bus Connector Kit for one pole, one end 1 S33928

Terminal Pad Kits for R-Frame Circuit Breakers


Terminal Pad Kit Field-Installable Kits
R-Frame 3P Kit (One 4P Kit (One End
Circuit Breaker Lugs per End Only) Only)
Usage Phase
DE3

DE3
Cat. No. Cat. No.
3000 A, 100% Rated Required for cable or bus 9 RL3TB RL3TB4
RLTB Terminal Pad Kit 3000 A, Standard (80% Rated) Required for cable or bus
2500 A, 100% Rated Required for cable or bus
8 RLTB RLTB4
2500 A, Standard (80% Rated) Required for cable, optional for bus
All Other R-Frame CIrcuit Breakers Required for cable, optional for bus
For cable connection to RLTB, use AL2500RK lug. See page DE3-42.
Terminal Shields and Phase Barriers
Dimension B Qty Per
Used With Description (in.) Cat. No. Kit
Frame Max. Wire Size

H- and J-Frame H-Frame 60 A 3 AWG 0.50 S37446 1


Short Lug Shielda
H-Frame Short Lug Mechanical Lugs H-Frame 150 A 3/0 AWG 0.50 S37447 1
Shield J-Frame Short Lug
Shield J-Frame 350 kcmil 0.24 S37448 1
Compatible with:
Phase barrier or
terminal shield Compression Lugs
PDC
extension past end Aluminum Copper
of circuit breaker
“B” See Table PDC6BD2 LV426988 LV426986
LV426911
B-, H- and J-Frame B-Frame Long Lug (2P)
Power Distribution Shield LV426912
Connectors and PDC6BD6 LV426989 LV426987 1.9 (3P) 1
Compression Lugs LV426913
(4P)
Extremity R-Frame Phase Barrier
of PDC6HD6 YA060HD CYA060HD
Molded Case H-Frame Long Lug 2.24 S37449 1
w/Mechanical Shield PDC3HD2 YA150HD CYA150HD
Lugs
J-Frame Long Lug PDC6JD4 YA150JD CYA150JD
Shield 1.68 S37450 1
PDC3JD2 b CYA250J3
3P Short Terminal Shield LTSS3P 1
3P MediumTerminal Shield LTSM3P 1
“B” See Table L-Frame 3P Long Terminal Shield LTSL3P 1
4P Medium Terminal Shield LTSM4P 1
4P longTerminal Shield LTSL4P 1
M-, P-Frame S33646
Phase Barriers 3
R-Frame S33998
a Short lug shields provide IP20 protection for mechanical lugs and are compatible with control wire terminals.
b J-frame terminal shield is not compatible with the YA250J35 compression terminal.

Miscellaneous H-, J-, and L-Frame Circuit Breaker Accessories


Accessory Description Field-Installed
Cat. No,
Bag of screws for accessory cover, L-frame S432552
Spare Parts 1 spare toggle extension, L-frame 32595
Set of 10 identification labels LV429226

11/18
01/20
08/21
DE3-38
PowerPact™ Circuit Breaker Accessories
Plug-In and Drawout Mountings Class 611, 612 / Refer to Catalogs 0611CT1001, 0612CT0101
Plug-In and Drawout Mountings for H- and J-Frame Circuit Breakers (3P or 2P in a 3P
module)
Factory Field-
Description Installed Installed
Cat. No. Cat. No.
Complete Factory-Assembled Plug-in base shipped with circuit breaker N
Circuit Breakers
Drawout cradle shipped with circuit breaker D
Circuit breaker Only HJ00
Plug-In Base
Plug-in base kit S29278
Circuit breaker only HJ00
Special Order Options for Plug-
In and Drawout Circuit Breakers Plug-in base kit S29278
Drawout Cradle Cradle side plates (fixed part of chassis) S29282
H-Frame and J-Frame H-Frame and J-Frame
Plug-in Mounting Drawout Mounting Circuit breaker side plates (moving part of
chassis) S29283
H-Frame Shutter Kit (set of two) S37442
J-Frame Shutter Kit (set of two) S37443
Fixed part 9-wire connector (mounted on S29273
Secondary base)
Disconnect Moving part 9-wire connector (mounted on
Accessories for Plug-In and Blocks circuit breaker) S29274
Drawout Support for 2-moving connectors S29275
Extended escutcheon with extended toggle handle S29284
Two position indicating switches (connected/disconnected) S29287
CIRCUIT BREAKERS

CIRCUIT BREAKERS
H-Frame Short Terminal Cover (3P) S37436
J-Frame Short Terminal Cover (3P) S37440

Plug-In and Drawout Mountings for L-Frame Circuit Breakers


Plug-in Mounting Drawout Mounting
Description Poles Factory Field- Factory Field-
Installed Installed Installed Installed
Cat. No. Cat. No. Cat. No. Cat. No.
3 N D
Kit (stationary and moving parts)

DE3
4 N D
DE3

3 S32514 S32514
Plug-in base
Stationary Part 4 S32515 S32515
Fixed part of chassis S32532
Circuit breaker only HJ00 HJ00
Moving part of chassis S32533
L-Frame Plug-In L-Frame Drawout Moving Part
3 2x S32562 2x S32562
Mounting Mounting Short terminal covers
4 2x S32563 2x S32563
a Price shown is for quantity of 1.

Plug-In and Drawout Accessories for L-Frame Circuit Breakers


Field-
Description Installed
Cat. No.
Fixed Part 9-wire connector S29273
9-wire connector S32523
Secondary Disconnecting Blocks Moving Part
Support for 3 moving connectors S32525
Fixed + Moving 9-wire manual auxiliary connector S29272
Shutters Two shutters for plug-in base 32521
Extended escutcheon for toggle S32534
Chassis Accessories Locking device (key lock is not included) S29286
L-Frame Disconnecting L-Frame Locking
Blocks Device Two position indicating switches (connected/disconnected) 29287

Termination Options
Termination Letter For factory-installed termination, place
N = Plug-in termination letter in the third block of the
D = Drawout circuit breaker catalog number.
L G L 3 6 4 0 0 U31X
Termination No.
Drawout Cradle and Accessories for P-Frame Circuit Breakers
Description Cat. No.
Drawout Cradle Product Selector
Cradle Front Connected Flat (FCF) SFCF12b
Connectors Rear Connected T Horizontal/Vertical (RCTH/RCTV) SRCTV12b
Modbus™ cradle communication module S33852
Safety shutters S48933
Secondary disconnects terminal shield S33763
Cradle position switch 1a/1b Form C— Connected/test/disconnected S33170
Low level cradle position switch 1a/1b Form C—Connected/test/disconnected S33171
Cell keying kit S33767
P-Frame Drawout Cradle Connections Disconnected position key locking—provision for Kirk or Federal Pioneer Lock S33772
Cradle Door interlock kit S33786
Accessories
Racking interior kit S33788
Door escutcheon (for replacement only, included with circuit breaker) S33857
Transparent cover S33859
Push-in terminal kit (3 wires) S33098
Push-in terminal kit (6 wires) S33099
Finger cluster S33166
Cluster grease (12 oz. tube) S48899
b Needs 2 kits per cradle.

11/18
01/20
08/21
DE3-39
Micrologic™ Electronic Trip Units
Class 611 / Refer to Catalog 0611CT1001
Micrologic Trip Unitsf for PowerPact H-, J-, and
L-Frame Circuit breakers
x– Standard Feature o – Available Option
Standard Ammeter Energy
PowerPact™ H-, J-, and L-Frame Micrologic™ Trip Units Features
3.2/3/3 3.2S/3.3S 5.2A/5.3A 6.2A/6.3A 5.2E/5.3E 6.2E/6.3E
LI x
LSIa x x x
LSIG / Ground-Fault Tripb x x
Ground-Fault Alarm/Tripb x x
Current Setting Directly in Amperes x x x x x x
True RMS Sensing x x x x x x
UL Listed x x x x x x
Thermal Imaging x x x x x x
LED for Long-time Pickup x x x x x x
Micrologic Standard
LED for Green “Ready” x x x x x x
Trip Unit
Up to 12 Alarms Used Together x x x x
Micrologic Ammeter and Digital Ammeter x x x x
Energy Trip Unit Zone-selective Interlockingc x x x x
Communications o o o o o o
LCD Display x x x x
PowerPact™ H-, J-, and L-frame molded case circuit breakers may be
Front Display Module FDM121 o o o o
specified with any of the following Micrologic Electronic Trip Units.

CIRCUIT BREAKERS
CIRCUIT BREAKERS

Advanced User Interface x x x x


Micrologic Standard 3.2/3.3 Trip Units Neutral Protectionb x x x x
• True RMS sensing
Contact Wear Indicationd
Incremental Fine Tuning of Settings
x
x
x
x
x
x
x
x
• LI, LSI trip configurations Load Profiled,e x x x x
• Field-interchangeable trip units Power Measurement x x
• LED long-time pickup and trip indication Power Quality Measurements x x
• Test kits available a The LSI with 3.2S/3.3S trip units have fixed short time and long time delays.
• Thermal imaging b Requires neutral current transformer on the three-phase four-wire loads
c ZSI for H/J frames is only OUT. for L-frame ZSI is In and OUT.
Micrologic Ammeter 5.2A/5.3A/6.2A/6.3A Trip Units d Indication available using the communication system only.
DE3

DE3
e % of hours in 4 current ranges: 0–49%, 50–79%, 80–89%, and >90% In.
Includes all features listed for Micrologic standard trip unit, as well as: f DC not available with electronic trip units.
• Advanced user interface
Micrologic Trip Unit Settings for H- and J-Frame
• Neutral protection
• Incremental fine tuning of settings Model Trip Function Trip Unit Ampere Setting
• Up to 12 alarms 15-20-25-30-35-40-45-50-60
• Digital ammeter—phase and neutral (4-pole only) LI 3.2
35-40-45-50-60-70-80-90-100
• Phase loading bar graph 50-60-70-80-90-100-110-125-150

• Maintenance indicators including contact wear, number of operations, Standard


70-80-100-125-150-175-200-225-250
15-20-25-30-35-40-45-50-60
operating hours, and load profiles
35-40-45-50-60-70-80-90-100
• Cause of trip information for troubleshooting assistance LSI 3.2S
50-60-70-80-90-100-110-125-150
• LCD Display 70-80-100-125-150-175-200-225-250
• Zone-selective interlocking (ZSI) (short-time & ground-fault) 15–60
• Optional Modbus™ communications—PowerLogic™ compatible LSI 5.2A
35–100
50–150
Micrologic Energy 5.2E/5.3E/6.2E/6.3E Trip Units 70–250
Ammeter
Includes all features listed for Micrologic ammeter trip unit, as well as: 15–60
35–100
• Ground-fault trip with programmable ground fault alarm (available on LSIG 6.2A
50–150
6.2E/6.3E only) 70–250
• Power and energy measurement 15–60
• Power quality measurements 35–100
• Current demand and power demand measurements
LSI 5.2E
50–150
70–250
Energy
15–60
35–100
LSIG 6.2E
50–150
70–250

Micrologic Trip Unit Settings for L-Frame


Model Trip Function Trip Unit Ampere Setting
70-80-100-125-150-175-200-225-250
LI 3.3 125-150-175-200-225-250-300-350-400
200-225-250-300-350-400-450-500-600
Standard
70-80-100-125-150-175-200-225-250
LSI 3.3S 125-150-175-200-225-250-300-350-400
200-225-250-300-350-400-450-500-600
125–400
LSI 5.3A
200–600
Ammeter
125–400
LSIG 6.3A
200–600
125–400
LSI 5.3E
200–600
Energy
125–400
LSIG 6.3E
200–600

11/18
01/20
08/21
DE3-40
Class 612 / Refer to Catalog 0612CT0101 Micrologic™ Electronic Trip Units
Powerpact P- and R-Frame, and Masterpact Micrologic Electronic Trip Units

Long-time Pickup Settings


Rating
Plug Long-time Pickup Settings
A 1.0 .90 .80 .70 .63 .60 .50 .45 .40
B 1.0 .95 .88 .75 .63 .56 .50 .44 .40
C 1.0 .95 .83 .75 .67 .56 .53 .50 .42
D 1.0 .95 .93 .90 .80 .70 .64 .48 .40
E 1.0 .95 .93 .90 .85 .80 .75 .70 .60
F 1.0 .98 .96 .94 .92 .90 .88 .86 .84
G .82 .80 .78 .76 .74 .72 .70 .68 .66
H .64 .62 .60 .58 .56 .54 .52 .50 .48

Micrologic Trip Units – Standard Feature o – Available Option


Standard Ammeter Power Harmonic
Features
3.0 5.0 3.0A 5.0A 6.0A 5.0P 6.0P 5.0H 6.0H
LI
LSI (Instantaneous can be turned off)
Standard Ammeter Power Harmonic Adjustable LSIG / Ground-Fault Trip
Trip Unit Trip Unit Trip Unit Trip Unit Rating Plug Ground-Fault Alarm (No Trip) ab
CIRCUIT BREAKERS

CIRCUIT BREAKERS
Ground-Fault Alarm and Trip ab
Powerpact® P-, R-Frame circuit breakers may be specified with any of Adjustable Rating Plugs
the following Micrologic Electronic Trip Units. True RMS Sensing
Micrologic (Standard) 3.0 and 5.0 Trip Units UL Listed
• True RMS sensing Thermal Imaging
Phase Loading Bar Graph
• LI, LSI trip configurations
LED for Long-time Pickup
• Field-interchangeable long-time rating plugs LED for Trip Indication
• LED long-time pickup indication Digital Ammeter
• Test kits available Zone-selective Interlocking

DE3
DE3

• Thermal imaging Communications o o o


LCD Dot Matrix Display
Micrologic (Ammeter) 3.0A, 5.0A and 6.0A Trip Units
Advanced User Interface
Includes all features listed for Micrologic standard trip unit, as well as: Protective Relay Functions
• LSIG trip configurations Neutral Protection a
• Digital ammeter—phase and neutral Contact Wear Indication
Incremental Fine Tuning of Settings
• Phase loading bar graph
Selectable Long-time Delay Bands
• LED trip indication Power Measurement
• Zone-selective interlocking (ZSI) (short-time & ground-fault) Power Quality Measurements
• Optional Modbus™ communications—PowerLogic® compatible Waveform Capture
Micrologic (Power) 5.0P and 6.0P Trip Units a Requires neutral current transformerin 3Ø4W systems.
b Requires M2C or M6C ProgrammableContact Module.
Power measurement and advanced protection features includes all features
listed for Micrologic ammeter trip unit, as well as: Micrologic Trip Unit and Options
• LSI trip configuration with programmable ground fault alarm Field-Installable Kit $ Price /
• LSIG (Ground-fault trip) with programmable ground fault alarm Model Protection Additional Features Cat. No.c Circuit Breaker
$ Price Adder
• Incremental “fine tuning” of L, S, I, and G pickup and delay settings 2.0 (IEC only) LSO S132R
• LCD dot matrix display and LED trip indication 3.0 (UL/ANSI only) LI None S131A
• Advanced user interface 5.0 LSI S133A
• Advanced protection IDMTL—selectable long-time delay bands 2.0A (IEC only) LSO S142Rd
3.0A (UL/ANSI only) LI S141Ad
• Neutral protection Ammeter
5.0A LSI S143Ad
• Power measurement 6.0A LSIG S144Ad
• Contact wear indication 5.0P LSI S163Ade
Metering, Adv. Protection
• Modbus communications—PowerLogic compatible 6.0P LSIG S164Ade
• Local and remote settings 5.0H LSI Metering, Adv. Protection S173Ade
6.0H LSIG & Harmonic Analysis S174Ade
Micrologic (Harmonic) 5.0H and 6.0H Trip Units
c The standard rating plug supplied with a trip unit will be the “A” rating plug. To specify an
Power quality measurement and advanced protection features. Includes all alternative adjustable rating plug, please add the letter designation to the end of the
features listed for the Micrologic power trip unit, as well as: catalog number. Please refer to page DE3-47 for a complete listing of adjustable settings
available with each plug. (Example: S143B would specify a “B” rating plug instead of the
• Enhanced power measurements functions standard "A" plug.) Use suffix “N” if no rating plug is required.
• Power quality measurements d When replacing a standard trip unit with Type A (Ammeter), P (Power metering) or H
(Harmonic analysis) trip unit, order the 12-pin connector kit S33101 for the Masterpact NW
and NT and the PowerPact P-frame drawout circuit breakers or kit S33100 for PowerPact
P-frame and R-frame unit-mount and I-Line circuit breakers. See page DE3-47.
Adjustable Rating Plugs—Selection e Requires Circuit Breaker Communications Module.

To provide maximum design flexibility, system protection, and field Special Options
upgradeability, each Micrologic® trip unit is equipped with an
Field-Installable
interchangeable long-time rating plug. Each trip unit requires an adjustable Description Factory-Installed Suffix
Cat. No.
rating plug to determine the long-time pickup range of the circuit breaker. Ship circuit breaker in closed position YK N/A
These plugs are factory-installed on new trip units, or can be ordered CT Characterization (Calibrated trip system) Q N/A
separately for field-installable upgrades. Alternate Maintenance Setting (AMS) kit
(use with 5.0/6.0 A, P or H and 5.3/6.3 a or E — 84957
Micrologic trip units)
Adjustable rating plugs are offered in eight different ranges of long-time
Energy Reduction Maintenance Setting
pickup adjustments. The following chart show the ranges of adjustments. (ERMS) kit — 84956
Each adjustment times the sensor rating (lr X In) of the circuit breaker sets (use with 5.0/6.0 P or H Micrologic trip units)
the long-time pickup value of the circuit breaker.

11/18
01/20
08/21
DE3-41
Micrologic™ Electronic Trip Unit
Micrologic™ Trip Unit Accessories Class 612 / Refer to Catalog 0612CT0101
Trip Unit Accessories
Adjustable rating plug "A" is installed as standard on all Device Frame Cat. No.
Micrologic trip unit orders. However, an alternative selection Pocket Tester S434206
may be specified from the "Assembled" table below, and UTA Tester STRV00910
factory-installed with your trip unit order at no additional Spare UTA Tester STRV00911
charge. To order, please attach the appropriate catalog BLuetooth/Modbus for UTA Tester H/J/L SVW3A8114
suffix to the end of the trip unit catalog number (after Spare Power Supply for UTA Tester
TRV00915
specifying trip unit options). Adjustable rating plugs may also 110–120 Vac
be purchased as field-installable components from the table Micrologic Cord for UTA Tester TRV00917
below. Micrologic 5/6 Cover, Transparent S429478
H/J
Micrologic 2/3 Cover, Transparent S429481
Rating Plugs Micrologic 5/6 Cover, Transparent
L
S432459
Micrologic 2/3 Cover, Transparent S432461
Factory-Installed Field-Installable LCD Display for Micrologic 5 S429483
Rating Pluga H/J/L
Cat. Suffix Cat. No. LCD Display for Micrologic 6 S429484
A A (standard) S48818 Hand-held Test Kit S33594
B B S48819 Primary Injection Test Adaptor S33937
Full Function Test Kit C C S48820 Full-function Adapter Kit S48981
D D S48836 Full-function Test Kit P/R S33595
E E S48837 Seven-pin Test Cable (for connection between S48907
F F S48838 test kit and trip unit)c
G G S48839 Two-pin Test Cable (for connection between
S48908
test kit and trip unit)d
CIRCUIT BREAKERS

H H S48840
230 Vac Filtered Power Corde S48856
a Long-time pickup amperes (Ir) = Sensor Rating (In) X Setting of rating
plug. 120 Vac Filtered Power Corde P/R S48855
Trip Unit Seal • “Fine adjustment tuning” is included on Micrologic Power and Harmonic trip Trip Unit Battery for Trip Indicator Lights S33593
units, allowing for incremental settings of 1 ampere between the plug setting Power supply with:
and .40 X Sensor Rating. 24–30 Vdc input 685823
Neutral Current Transformers 48/60 Vdc input 685824
125 Vdc input H/J/L/P/R 685825
For Use with Cat. No. Sensor
Circuit Breaker 110–130 Vac input 685826
200–240 Vac input 685827
S429521 60–100
H-Frame 380–415 Vac input 685829
S430562 150
DE3

Micrologic A Trip Unit Cover, clear S33592


J-Frame S430563 250
Micrologic P/H Trip Unit Cover, P/R
L-Frame S432575 400–600 S47067
opaque gray
S33575b 250 Trip Unit Seal (6 pieces)
P-Frame H/J/L/P/R MICROTUSEAL
S33576b 400–1600 for compliance with NEC 240.6(c)
S48916b 250 12-pin Trip Unit Connector for
Sensor Plug NT/NW Masterpact Circuit Breakers S33101
S34036b 400–1600
R-Frame 12-pin Trip Unit Connector for P/R
S48896b 2000 S33100
P- and R-Frame Circuit Breakers
S48182b 3000
Battery Back-up (12 Hours) 685831
All NCTWIRING All
b Includes NCTWIRING kit. c Used for testing Micrologic trip units. Included in the price of the Hand-
held/Full-function Test Kits. Kit for replacement only.
d Used for testing STR trip units. Included in the price of the Hand-
held/Full-function Test Kits. Kit for replacement only.
e Included in the price of the Full-function Test Kit. Kit for replacement
only.

Sensor Plugs for P- and R-Frame Circuit Breakersfh


Circuit Sensor Plug Sensor Plug Circuit Breaker Frames Accepting Sensor Plug
Breaker Range Catalog No.
P-Frame Circuit Breaker 250 A 400 A 600 A 630 Ag 800 A 1000 A 1200 A 1250 Ag 1600 A
250 A S47052 X
400 A S47053 X X X
600 A S48823 X X X X
UL
800 A S33092 X X X
1000 A S33093 X X
1200 A S48824 X
630 A S33091 X X X X X
800 A S33092 X X X X
IEC 1000 A S33093 X X X
1250 A S33094 X X
1600 A S33095 X
R-Frame Circuit Breaker 600 A 800 A 1000 A 1200 A 1600 A 2000 A 2500 A 3000 A 3200 A
600 A S48823 X X X X
800 A S33092 X X X X
1000 A S33093 X X X X
1200 A S48824 X X X X
UL
1600 A S33095 X X X X
2000 A S33982 X X X
2500 A S33983 X X
3000 A S48825 X
1600 A S33095 X X X X X
2000 A S33982 X X X X
IEC
2500 A S33983 X X X
3200 A S33984 X
f For use only with circuit breakers with date codes later than 07011.
g IEC Only.
h See rating plug for long-time pickup range on page DE3-48.

11/18
01/20
08/21
DE3-42
Micrologic™ Electronic Trip Unit
Class 0611, 612 / Refer to Catalogs 0611CT1001, 0612CT0101 Micrologic™ Trip Unit Accessories
Trip Unit Field-Installable Accessories for P- and R-Frame Circuit Breakers
Factory- Field-Installable Kit Cat. No.
Description Installed P-Frame R-Frame
Cat. No.
Unit Mount I-Line Motor Operated Drawout With Rotary Handle Unit Mount I-Line
Circuit Breaker Communication Module (BCM) (Modbus) E1 S64205 S64205 S64207 S64206 S64205 S64205 S64205
Two Programmable Contacts Module (M2C) V S64273 S64273 S64273 S64273 S64273 S64273 S64273
Six Programmable Contacts Module (M6C) W S64204 S64204 S64204 S64202 S64204 S64201 S64201
External Voltage Sensing (EVS) YV S64203 S64203 S64210 S64209 S64210 S64208 S64208

Trip Unit Accessories


Description Factory-Installed Field-Installable
Cat. No. Suffix Kit Cat. No.
External Accessories
Modbus Interface Module IFMa — LV434000
Stacking Connections for IFM (10) — TRV00217
IFE Interface (Ethernet Module) — LV434001
IFE Interface + Gateway (Ethernet and Modbus Gateway) — LV434002
I/O Module (Input/Output ProgrammableModule) — LV434063
L = 0.35 m (1.15 ft) — LV434195
Circuit Breaker ULP Cord–BCM to COMS L = 1.3 m (4.27 ft) — LV434196
L = 3 m (9.24ft) — LV434197
L = 0.3 m (0.98ft) — TRV00803
Breaker Status and ULP Cable, 10 Cables (Male to Male RJ45)
L = 0.6 m (1.97 ft) — TRV00806

CIRCUIT BREAKERS
Control Module (BSCM)
L = 1 m (3.28 ft) — TRV00810
Modbus Interface ULP Cable, 5 Cables (Male to Male RJ45) L = 2 m (6.56 ft) — TRV00820
Module (IFM) L = 3 m (9.84 ft) — TRV00830
ULP Cable, 1 Cable (Male to Male RJ45) L = 5 m (16.40 ft) — TRV00850
RJ45 Female/Female Connector, 10 Connectors — TRV00870
ULP Line Terminator, 10 Terminators — TRV00880
Insulated ULP Module and Circuit Breaker Cord L = 1 m (3.28 ft) — S434204
(for System Voltage Greater than 480 Vac) (Cord with Female L = 3 m (9.84 ft) — S434303
Modbus Line Terminator, 2 Terminators — VW3A8306DRC
Front Display Module FDM121a — STRV00121

DE3
FDM Mounting Accessory (Dia. 22 mm) — TRV00128
FDM128 (8 Circuit Breakers to 1 Front Display) LV434128
ZSI Interface Module — S434212
Internal Accessories
NSX Cord for
NSX Cord b L = 1.3 m EA S434201
Front Display Module Modbus Communications (for Modbus Communication) L=3m EB S434202
(FDM)
L = 1.3 m EGf S434201BS
BSCM (Breaker Status and Control Module) with NSX Cordb
L=3m EHf S434202BS
Replacement BSCM — S434205
L = 1.3 m ED S434204
NSX Cord for V > 480 Vacb
L=3m EE S434303
L = 1.3 m EKf S434204BS
BSCM with NSX Cord for V > 480 Vacb
L=3m ELf S434303BS
24 Vdc Terminal Block EN S434210
SDTAM 24/415 Vac/dc Modulec V S429424
SDX Module 24/415 Vac/dcd V S429532
a Require NSX or ULP Cord
b Installation requires IFM for Modbus communication and/or FDM for external display
c Remote indication relay for motor applications
d Remote indication relay
SDTAM Module ZSI Interface Module
e For proper selection, see catalog 0611CT1001.
(Remote indication relay f If using with motor operator requires communicating motor operator (suffix NC).
(Connects PowerPact H/J/L
for motor applications) circuit breakers to Wire Harnessg for H-, J-, and L-Frame Circuit Breakers
PowerPact P/R and Factory-Installed Field-Installable Kit Cat. No.
Masterpact NT/NW circuit Description
Cat. No. Suffix Cat. No.
breakers) ZSI Wire Harness, H/J Frame YH3 S434300
ZSI Wire Harness, L-Frame YH3 S434301
ENCT Wire Harness YH2 S434302
OF Wire Harness YH1 S434500
SD/SDE Wire Harness YH1 S434501
SDx/SDTAM Wire Harness YH1 S434502
MN Wire Harness YH1 S434503
MX Wire Harness YH1 S434504
24 Vdc Terminal Block Wire Harnessh YH1 S434505
Motor Operator Wire Harness YH1 S434506
Communicating Motor Operator Wire Harness YH1 S434507

g Wire harness is required for I-Line applications, optional for unit-mount applications
YH1 = all installed accessories but ZSI and ENCT
YH2 = ENCT and all installed accessories
YH3 = ZSI and all installed accessories
YH4 = ZSI, ENCT and all installed accessories
h I-Line wire harness is included for communication network accessories.
Optional wire harness for unit mount requires YH1 suffix.

11/18
01/20
08/21
DE3-43
Dimensions and Shipping Weights
Miniature and Molded Case Circuit Breakers
Figure 1 Figure 2 Figure 3 QO, QOB QO™, QOU, Multi 9™ Circuit Breakers
A A A D Circuit Breaker Dimensions—Inches
G No. Fig.
G G C Catalogue No. Poles No.
Prefix A B C D E F G
1 1 0.75 3.00a 2.31 2.91 2.25 ... 0.59
B E B E B E QO, QOB 2 2 1.50 3.00a 2.31 2.91 2.25 ... 1.34
3 3 2.25 3.00a 2.31 2.91 2.25 ... 2.09
QOB-VH 150 A 2 2 3.0 5.72 2.53 4.90 3.78 ... 2.85
QOB-VH 110–150 A 3 3 4.50 5.72 2.53 4.90 3.78 ... 4.35
Figure 4 Figure 5 QO-GFI, QO-PL
1 4 0.75 4.12b 2.31 2.91 2.25 ... 0.59
A A QO-EPD QO-PL
G G D QO-GFI 2 5 1.50 4.12b 2.31 2.91 2.25 ... 1.34
QO-EPD
C 3 5 2.25 4.12b 2.31 2.91 2.25 ... 2.09
1 6 0.75 4.05c 2.38 2.98 2.25 5.00e 0.62
E E QOU
B B 2 7 1.50 4.05c 2.38 2.98 2.25 5.00e 1.37
Low Ampere
3 8 2.25 4.05d 2.38 2.98 2.25 5.00f 2.12
1 9 0.75 4.45 2.37 2.96 2.25 6.78 ...
QOU
2 10 1.50 4.45 2.37 2.96 2.25 6.78 ...
High Ampere
3 11 2.25 4.45 2.37 2.96 2.25 6.78 ...
Figure 6 Figure 7 Figure 8 QOU, QYU 1 13 0.71 4.06 1.89 2.83 1.77 — —
A A Low Ampere

CIRCUIT BREAKERS
A
CIRCUIT BREAKERS

Multi 9™ C60BP 2 14 1.42 4.06 1.89 2.83 1.77 — —


G G G D
3 15 2.13 4.06 1.89 2.83 1.77 —
C
1 13 0.71 5 1.89 2.83 1.77 — —
Multi 9™ C6BPR 2 14 1.42 5 1.89 2.83 1.77 — —
B E B E B E 3 15 2.13 5 1.89 2.83 1.77 — —
F
1 13 0.71 3.19 1.73 2.83 1.77 — —
2 14 1.42 3.19 1.73 2.83 1.77 — —
Multi 9™ C60SP
3 15 2.13 3.19 1.73 2.83 1.77 — —

QOU 4 16 2.83 3.19 1.73 2.83 1.77 — —


DE3

DE3
Figure 9 Figure 10 Figure 11
High Ampere a 35–70 A is 3.12 in; 80–100 A 2-pole and 70–100 A 3-pole are 3.50 in.
Figure 10 Figure 11 Figure 12 D b QO-PL is 4.55 in.
C c 80–100 A 1-pole and 80–125 A 2-pole are 4.45 in.
A A A d 70–100 A 4.45 in.
e 80–100 A 1-pole and 80–125 A 2-pole are 6.78 in.
f 70–100 A is 6.78 in.

B F
B E B E B E
QB, QD, QG, QJ, Q4, LA, LH Circuit Breakers
Circuit Breaker No. Fig. Dimensions—Inches
Catalogue No.
Prefix Poles No. A B C D E F G H
Figure 13 Figure 14 Figure 15 Figure 16 C60
A A QB, QD, 2 22 6.47 3.00 3.02 3.93 g 4.25 ... ...
A A D
QG, QJ 3 23 6.47 4.50 3.02 3.93 g 4.25 1.50 0.75
C
Q4L, LAL, LHL 2&3 23 11.00 6.00 4.06 5.84 0.88 9.25 2.00 1.00
B B B B g Dimensions E are 1.59 in at ON end and 0.63 in at OFF end.
E

Figure 17 Figure 18 Figure 19 Figure 20 Shipping Weightsh


A A A A
Frame Size Approx. Shipping Frame Size Approx. Shipping
Weight (Lbs.) Weight (Lbs.)
B B B B FAL, FHL 1P 2
FAL, FHL 2P 3 LAL, LHL 15
FAL, FHL 3P 5
Q4L 15
Figure 1 Figure Figure 3
B QB, QD, QG, QJ 4
E B E B
G G D
E HH C h All weights are for 3P circuit breakers unless otherwise noted.
CL
A F CL
A F
A F

E E

Figure 24 E
B D
G C
E

A F

11/18
01/20
DE3-44
08/21
Dimensions and Shipping Weights
Molded Case Circuit Breakers
Figure 25 Figure 26
B PowerPact B-, H-, J- and L-Frame Circuit Breakers
E
B G
Circuit Breaker Dimensions — Inches
Cat. No. No. of Fig. No.
Prefix Poles A B C D E F G H
1 35 6.79 1.06 3.15 4.01 0.20 6.33 — 5.39
A F A F B-Frame 2 36 6.22 2.12 3.15 4.01 0.86 4.48 — 5.39
D
3 37 6.22 3.18 3.15 4.01 0.86 4.48 1.06 5.39
E
C 4 38 6.22 4.25 3.15 4.01 0.86 4.48 2.12 5.39
HD, HG, HJ, 2* 25 6.40 2.74 2.87 4.36 0.74 4.92 — —
HL, HR 3 26 6.40 4.12 2.87 4.36 0.74 4.92 1.38 —
JD, JG, JJ,
3 27 7.52 4.12 2.87 5.00 1.30 4.92 1.38 —
Figure 27 JL, JR
B LD, LG, LJ, LL, LR 3 28 13.38 5.51 3.75 6.61 2.22 7.87 1.77 —
G
* - Only HD and HG are in 2P module. The HJ, HL and HR 2P breakers are in 3P modules

ED, EG and EJ Circuit Breakers


D
F Circuit Dimensions — Inches
A C Breaker No. of Fig. No.
Catalogue No. Poles A B C D E
E Prefix

CIRCUIT BREAKERS
1 29 0.98 5.66 3.09 4.05 3.32
ED, EG, EJ 2 30 1.96 5.66 3.09 4.05 3.32
3 30 2.94 5.66 3.09 4.05 3.32
Figure 28
G GJ 3 32 3.54 4.72 2.76 3.94 2.20

MG, MJ, PG, PJ, PL, RG, RJ and RL Circuit Breakers


A
Circuit Breaker No. of Fig. Dimensions — Inches
Cat. No. Poles No.
F Prefix A B C D E F G

DE3
MG, MJ
(800 A and below) 2, 3 33 12.86 8.27 5.77 8.05 2.49 7.87 7.83
PG, PJ, PK, PL 2, 3 33 16.16 8.27 5.77 8.05 4.19 7.87 7.83
(1000–1200 A)
RG, RJ, RK, RL 2, 3 34 16.24 16.54 6.63 14.49 8.73 14.25 15.35
C B
D
Shipping Weightsa
Approx. Shipping Approx. Shipping
Figure 29 Figure 30 Figure 31 Frame Size
Weight (Lbs.)
Frame Size
Weight (Lbs.)
HD, HG, HJ, HL 2P 4 JD, JG, JJ, JL, JR 5
HD, HG, HJ, HL, HR 3P 5 LD, LG, LJ, LL, LR 14
29
E B B E E B ED, EG, EJ 1P 2 MG, MJ

ED, EG, EJ 2P 3 PG, PJ, PK, PL 32


ED, EG, EJ 3P 4 RG, RJ, RK, RL (Without RLTB) 52
a All weights are for 3P circuit breakers unless otherwise noted.
A A A C
D

Figure 32 Figure 33
B D
G C

E B E

AF
A C
D
E

Figure 34
B
G D
F C

AE

DE3-45
11/18
08/21
01/20
Circuit Breaker Enclosures
Enclosures Class 610

PowerPact B-Frame Circuit Breaker Enclosures


The enclosures' maximum short circuit ratings are 65 kA at 600Y/347 Vac, 65 kA at 480 Vac, 100 kA at 240 Vac and 50 kA at 250 Vdc
unless otherwise noted. Enclosures are not suitable for use as Service Entrance Equipment unless otherwise noted.
Enclosures accept 100% rated circuit breakers (60A max.)a

PowerPact B-Frame Circuit Breaker Enclosures


Circuit Breaker
Enclosure Cat. No. Accessory Cat. No.
Cat. No. Prefix Rating Poles
Type 1 Flush Type 1 Surface Type 3R Neutral Assembly Kit Service Ground Kit
BDL, BGL, BJL, BKL 15-100 A 2, 3 SN100FA
B125F B125S B125RB PKOGTA2
BDL, BGL, BJL 110-125 A 2, 3 SN225KA
BDL, BGL, BJL 15-100 A 3 CB125NRBb SN100FA installed PKOGTA2
Type 4, 4X, 5 Stainless Type 4, 4X, 5 Stainless Type 12/3R without
Steel Type 304 Steel Type 316 knockouts
BDL, BGL, BJL, BKL 15-100 A 2, 3 SN100FA
B125DS B125SS B125AWK
BDL, BGL, BJL 110-125 A 2, 3 SN225KA PKOGTA2
BDL, BGL, BJL 110-125 A 3 — — CB125NAWKb SN225KA installed

PowerPact H- and J-Frame Circuit Breaker Enclosures


CIRCUIT BREAKERS

The enclosures' maximum short circuit ratings are 25 kAIR at 600 Vac, 65 kAIR at 480 Vac, 125 kAIR at 240 Vac and 20 kA at 250
Vdc unless otherwise noted. Enclosures are not suitable for use as Service Entrance Equipment unless otherwise noted. Enclosures
accept 100% rated circuit breakers unless otherwise noteda. The enclosures are not compatible with motor operator, earthleakage
or ground-fault modules.

PowerPact H- and J-Frame Circuit Breaker Enclosures


Circuit Breaker
Enclosure Cat. No. Accessory Cat. No.
Cat. No. Prefix Rating Poles
DE3

Type 1 Flush Type 1 Surface Type 3R Neutral Assembly Kit Service Ground Kit
HDL 15-100 A 3 — HD100Sefg — SN100FA PKOGTA2
110-225 A SN225KA
HDL, JDL 3 — JD250Shfg — PKOGTA2
110-225 A SN400LA
15-100 A 2 SN100FA
HDL, HGL H150F H150S H150Ri PKOGTH150
110-150 A 2 SN400LA
HJL, HLL 15-100 A 2
SN100FA
15-100 A 3 PKOGTH150
HDL, HGL, HJL, HLL J250F J250Sj J250Rik
110-150 A 3
SN400LAl
JDL, JGL, JJL, JLL 150-250 A 2, 3 PKOGTJ250
HDL, HGL, HJL, HLL 110-150 A 3 PKOGTH150
— CJ250NSb CJ250NRb SN400LA installed
JDL, JGL, JJL, JLL 150-250 A 2, 3 PKOGTJ250
NEMA 4, 4X, 5,Type NEMA 4, 4X, 5, Type NEMA 12/3R Without
304 Stainless Steel 316 Stainless Steel Knockouts
15-100 A 2, 3 SN100FA
HDL, HGL, HJL, HLL PKOGTH150
110-150 A 2, 3 J250DS[1] J250SS[1] J250AWK[1]
SN400LAl
JDL, JGL, JJL, JLL 150-250 A 2, 3 PKOGTJ250
HDL, HGL, HJL, HLL 110-150 A 2, 3 PKOGTH150
— — CJ250NAWKb SN400LAl
JDL, JGL, JJL, JLL 150-250 A 2, 3 PKOGTJ250

PowerPact L-Frame Circuit Breaker and Molded Case Switch Enclosures


Enclosures are not suitable for use as Service Entrance Equipment unless otherwise noted. Enclosures accept 100% rated circuit
breakers to 400 amps. The enclosures have a blank top end wall and require field-cut openings.

Circuit Breaker Enclosure Cat. No. Accessory Catalogue No.


Type 4, 4X, 5 Type 12/3R without Copper Only Neutral
Cat. No. Prefix Rating Poles Neutral Assembly Kit Service Ground Kit
Stainless Steel knockouts Assembly Kit
70-400 A SN400LA SNC400LX
LDL, LGL, LJL, LLL, LRL 3 — L600AWK[2][1]
125-600 A SN1000MA SNC800LX
LDL, LGL, LJL, LLL, LRL 200-600 3 — CL600NAWKb SN1000MA installed — PKOGTA4
400 A SN400LA SNC400LX
LGLc, LLLc, LRLc 3 — L600AWKMCd
600 A SN1000MA SNC800LX

a Use only 90°C (minimum) rated wire sized per ampacity of 75°C rated conductors for 100% rated circuit breakers.
b Suitable for use as as Service Entrance Equipment.
c Molded Case Switch.
d Enclosures accept Molded Case Switches.
e Rated for 240 Vac maximum. Short circuit current rating is 25 kAIR at 240 Vac.
f Accepts standard 80% rated circuit breakers only. Not rated for 100% rated circuit breakers.
g Use copper conductors only.
h Rated 480 Vac maximum. Short circuit current rating is 18 kAIR at 480 V.
For conduit entry through the top end wall use one of the following Square D conduit hubs: A200L for 2.00 in., A250L for 2.50 in., A300L for 3.00 in.,
i
A350L for 3.50 in. or A400L for 4.00 in. For enclosure suitable for use as Service Equipment use Cat. No. CJ250NR.
j Add suffix BE if no knockouts are required on the end walls. For enclosure suitable for use as Service Equipment use Cat. No. CJ250NS.
k For access to the circuit breaker’s standard, ammeter or energy trip unit, add suffix T.
l For 200% neutral use copper wire only.
m Complete rating is Type 3, 3R [14], 4, 4X, 5, and 12.
n For Type 3R applications, remove drain screw from bottom endwall.
[1] Add suffix VW for visibility to the standard, ammeter or energy trip unit of the PowerPact circuit breaker.
[2] Enclosures accept PowerPact L-frame circuit breakers and Motor Protectors with suffixes M38X.

01/20
11/18
08/21
DE3-46
Circuit Breaker Enclosures
Class 610

Q-Frame Circuit Breaker Enclosures


The enclosures for Q Frame Circuit Breaker are cUL listed. The short circuit ratings of these enclosed circuit breakers are equal to
the interrupting ratings, at the supply voltage marked on the circuit breaker installed, unless otherwise noted.

Circuit Breaker
Enclosure Cat. No. Accessory Cat. No.
Cat. No. Prefix Rating Poles
Type 1 Flush Type 1 Surface Type 3R Neutral Assembly Kit Service Ground Kit
QBL, QDL, QGL,
70-225 A 2, 3 Q23225NFC Q23225NSC Q23225NRBC Installed PKOGTA2
QJL a

LA, LH, Q4 Circuit Breaker Enclosures


Circuit Breaker
Enclosure Cat. No. Accessory Cat. No.
Cat. No. Prefix Rating Poles
Type 1 Flush Type 1 Surface Type 3R Neutral Assembly Kit Service Ground Kit

CIRCUIT BREAKERS
125-225 A
LAL, LHL, Q4L 2, 3 LA400F LA400S LA400Rf SN100FA
225-400 A PKOGTA2
LAL 125-400 A 3 — LA400LSde — SN225KA
Type 4, 4X, 5 Stainless Type 4, 4X, 5 Stainless Type 12/3R without
Steel Type 304 Steel Type 316 knockouts
125-225 A SN225KA
LAL, LHL, Q4L 2, 3 LA400DS — LA400AWK PKOGTA2
225-400 A SN400LA

DE3
a When 3P QJL circuit breaker is installed in the enclosure, the enclosure is limited to Short Circuit Current ratings of 65 kAIR at 240 V and
100 kAIR at 208 V.
b Complete rating is Type 3, 3R, 4, 4X, 5, and 12.
c For Type 3R applications, remove drain screw from bottom endwall.
d Use copper conductors only
e Rated 480 Vac maximum. Short circuit current rating is 30 kA at 480 V.
f The LA400R enclosures have a blank top end wall and require field-cut openings.

01/20
08/21
11/18 DE3-47
Circuit Breaker Enclosures
Enclosures Class 610

PowerPact M- and P-Frame Circuit Breaker Enclosures


All enclosures will accept 80% rated circuit breakers. The P1200 enclosures will accept
100% rated circuit breakers to 800 A. If a CT neutral is required, the enclosure will no
longer accept a 200% neutral. The M800R and the P1200R enclosures have a blank top
end wall and require field-cut openings.
PowerPact M- and P-Frame Circuit Breaker Enclosures
Circuit Breaker Enclosure Cat. No.
Neutral Assembly Service Ground
Cat. No. Prefix Rating Poles Enclosure Kit 200& Neutral Kit CT Neutral Kit ab Kit
NEMA 1 Flush NEMA 1 Surface NEMA 3R
MGL, MJL, PGL, PJL, SN800SNI and
300-800 A 2, 3 — M800S M800R AL800SN S33576MK PKOGTA4
PKL, PLL 2 each SN1200
PGL, PJL, PKL, PLL 250-1200 A 2, 3 — P1200S P1200R SN1200 S33576MK PKOGTA4
NEMA 4, 4X, 5c NEMA 4, 4X, 5c NEMA 12/3R
Type 304 Stainless Type 316 Stainless Without
Steeld Steeld Knockoutsd
MGL, MJL, PGL, PJL,
300-800 A 2, 3 M800DS M800SS M800AWK AL800SN — S33576MK PKOGTA4
PKL, PLL
PGL, PJL, PKL, PLL 250-1200 A 2, 3 — — P1200AWK SN1200 — S33576MK PKOGTA4
CIRCUIT BREAKERS

a Order current transformer kit S33576 seperately.


b Current transformers applicable only on PowerPact P circuit breakers. Current limitations are
400–800 A and 400–1200 A respectively for the M800 and P1200 family of enclosures.
c Complete rating is NEMA 3, 3R, 4, 4X, 5, and 12.
d For NEMA 3R applications, remove drain screw from bottom endwall.

PowerPact L-Frame 500 Vdc Circuit Breaker Enclosures


The PowerPact L-frame circuit breaker enclosure's maximum short circuit rating is 20
DE3

kAIR at 250 Vdc and 50 kAIR at 500 Vdc.


Listed for use ONLY on UPS systems.
DC CIrcuit Breaker Enclosures for LG and LL DC-Rated Circuit Breakers
Circuit Breakere NEMA 1 Surface Replacement Ground Service Ground Kit
Enclosure Lugs
Cat. No. Prefix Ampere Rating Poles Cat. No. Cat. No. Cat. No.
300-600 A 3 L1200S
LGL, LLL 8010440301 Standard
700-1200 A 4 L1200S
e Use 500 Vdc or 250 Vdc rated circuit breakers only.

11/18
01/20
08/21
DE3-56
DE3-48
Circuit BreakerEnclosures
Class 610 Enclosure Accessories and Dimensions

Enclosure Accessories
Neutral Kit Terminal Data
Terminal Lug Data - Total Available (Line plus All Copper Neutral Terminal Lug Data - Total
Neutral Kit Catalog Number Load) AWG/kcmil AL/CU Available (Line plus Load) AWG/kcmil
(2) 14-1/0 Cu or
100SNA (2) 12-1/0 AI plus (1) 14-4 Cu —
(4) 14-1/0 Cu or
SN100FA (4) 12-1/0 AI —
SN225KA (2) 4-300 AI/Cu, plus (2) 14-1/0 AI/Cu —
225SNA (4) 6-350 AI/Cu —
(2) 1-600 or
400SN —
(4) 1-250 AI/Cu, plus (2) 4-300 AI/Cu
SN400LA (2) 1-600 or —
(4) 1-250 AI/Cu, plus (2) 4-300 AI/Cu
SN1000MA (6) 3/0-500 AI/Cu, plus (1) 1-4/0 AI/Cu —
SNC400LX — (2) 2-600 Cu, plus (2) 6-250 Cu
SNC800LX — (4) 2-600 Cu, plus (1) 2-4/0 Cu
AL800SN (6) 3/0-500 AI/Cu, plus (2) 6-350 AI/Cu —
SN1200 (8) 3/0-750 AI/Cu, plus (2) 6-350 AI/Cu —
S33576MK (8) 3/0-500 AI/Cu, plus (2) 4-300 AI/Cu —

CIRCUIT BREAKERS
Service Ground Terminal Data
BREAKERS

Service Ground Kit Catalog Number Terminal Data AWG/kcmil Lugs per kit
PKOGTA2 10-2/0 Cu or 6-2/0 AI 2
PKOGTH150 14-2 AI/Cu 1
PKOGTJ250 6-300 AI/Cu 2
PKOGTA4 6-250 AI/Cu 4

Dimensions (inches)

DE3
Enclosure Cat. No.
Cat. No. H W D
Series
in. mm in. mm in. mm
B125AWK, CB125NAWK A1 19.50 495 9.13 232 4.88 124
B125DS A1 19.50 495 9.13 232 4.88 124
B125F A1 19.50 495 9.88 251 4.13 105
B125RB, CB125NRB A1 18.00 457 8.88 226 4.88 124
B125S A1 18.13 461 8.63 219 4.13 105
HD100S A01 17.00 431.8 7.90 200.7 4.75 120.7
H150F A01 32.40 823 15.40 391 6.00 152
H150R A01 31.50 789 14.47 368 6.28 160
H150S A01 31.36 797 14.36 365 6.00 152
J250F A01 32.40 823 15.40 361 6.00 152
J250S, CJ250NS A01 31.36 797 14.36 365 6.00 152
J250R, CJ250NR A01 31.05 789 14.47 368 6.28 160
J250DS, J250SS A01 32.26 819 9.72 247 7.94 202
J250AWK, CJ250NAWK A01 32.26 819 9.72 247 7.94 202
LA400AWK E2 42.25 1073 13.75 349 7.25 184
LA400DS E2 42.25 1073 13.75 349 7.25 184
LA400F E2 45.63 1159 16.50 419 6.50 165
LA400R E2 44.00 1118 15.38 391 7.88 200
LA400S E2 44.50 1130 15.38 391 6.50 165
L600AWK, CL600NAWK E3 57.50 1461 20.38 518 8.25 210
M800S A1 40-3/8 1025.52 21 533.4 9-3/4 247.65
M800R A1 40-3/8 1025.52 21 533.4 9-3/4 247.65
M800DS, M800SS A1 40-7/8 1036.96 20-3/4 527.05 9-1/2 241.3
M800AWK A1 40-7/8 1036.96 20-3/4 527.05 9-1/2 241.3
P1200S A1 52-1/8 1323.98 21 533.4 9-3/4 247.65
P1200R A1 52-1/8 1323.98 21 533.4 9-3/4 247.65
P1200AWK A1 53 1346.20 20-3/4 527.05 9-1/2 241.3
Q23225NFC E5 26.25 667 9.88 251 4.75 121
Q23225NRBC E5 26.25 667 9.88 251 5.50 140
Q23225NSC E5 26.25 667 9.88 251 4.75 121

H
H H H
H

W W D
D W D
W D
W
Type 1 Type 3R Type 7, Type 9 Type 4, 4X, 5, 12, 12K

01/20
08/21
DE3-49
Moulded Case Circuit Breakers
CDP Breaker Cross to Square D

CDP Connector Kits

The CDP connector kits are used to install Square D breakers into existing Federal Pioneer CDP panels and Switchboard distribution interiors that originally
used branch breakers from the Horizon family.
Please note that these connector kits are designed to be applied on CDP interiors with Extruded Bus only, (except HDCMH, JDCMH, and LDCMH that can be
also used on CDP interiors with Flat Bus).
Please refer to installation bulletins for detailed information on these kits.

Retrofitting or adding new Square D Breakers into CDP Interiors


Federal Pioneer
Amperage Alternate Square D Breaker Connector Mounting Hardware
Horizon Breaker
15A – 100A 15A – 150A Powerpact H HDCMH
CE Breaker
150A – 250A 150A – 250A Powerpact J JDCMH
CJL Breaker 100A – 400A LA/LH LACMH
CJM Breaker* 300A – 600A 400A-600A PowerPact L LDCMH
CK 250A – 1200A Powerpact P PCDPCMH
CIRCUIT BREAKERS

Need to be replaced in pairs, can not mount a CE breaker back to back with a PowerPact breaker. Not suitable for 100% rated and type HR, JR
MCCBs.
Available only as single mount option. Not available as a double mount or Back to back mount due to dimensional constraints.
Condition 1: Panel with all single row branch circuits.
A minimum branch circuit height of 8-1/4” is required.
Condition 2: Panel with all double row branch circuits.
This will require a modification to the trim to remove a section of the trim centre strip in the location where the new breaker is to be installed.
A minimum branch circuit height of 9-5/8” is required and the breaker should be located where the centre strip ends. (This space includes
DE3

one 1 -3/8” wide filler to support the center strip).


If the breaker must be located between two sections of a double row trim then the minimum branch circuit height required is 11”. (This space
includes two 1-3/8” wide fillers to support both ends of the centre strips)
The PowerPact L-Frame breaker has an overall height of 5-1/2” but will be fitted with a Cover plate to fill the existing branch circuit space of
8-1/4”.
Available only for single mount. The CK breaker can not be replaced in existing 12X of branch circuit height, the Square D PowerPact breaker
requires space with a 16X branch nominal height.
* PowerPact L-Frame can also be used to replace Square D LC/LI/LX/LE/LXI installed in CDP panels as a replacement of CJM breakers.

11/18
DE3-50
08/21
DE3-50
Intentionally left blank

You might also like