13 Order Codes and Accessories

This document provides order codes and accessories information for a transformer protection relay: - The order code includes slots to specify the application, supply voltage, I/O cards, options, measurement card, communication interface, display, voltage withstand, product version, and region. - Accessories like cables of different lengths can be ordered separately using additional codes. - Notes specify that if slot 8 = 1 or 2, then slot 4 = 1, and that all circuit boards are conformally coated.

Uploaded by

Tosikur Rahman
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
514 views

13 Order Codes and Accessories

This document provides order codes and accessories information for a transformer protection relay: - The order code includes slots to specify the application, supply voltage, I/O cards, options, measurement card, communication interface, display, voltage withstand, product version, and region. - Accessories like cables of different lengths can be ordered separately using additional codes. - Notes specify that if slot 8 = 1 or 2, then slot 4 = 1, and that all circuit boards are conformally coated.

Uploaded by

Tosikur Rahman
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

13 Order codes and accessories Transformer protection relay

13 Order codes and accessories

13.1 Order codes


When ordering, state:
• Order code of the relay
• Quantity
• Accessories (see the order codes in section Accessories)

Figure 235 - P3T32 order code


Slot 1 2 3 4 5 6 7 8 9 10
P3T32 - D G G 1 A - D A 2 C A - B A A A A

Application
T32 = Transformer protection relay with differential protection

Nominal Supply voltage [V]


C = Power C 110-230 V (80 .. 265 Vac/dc, 5 x DO heavy duty, A1, SF)
D = Power D 24-48 V (18 .. 60 Vdc, 5 x DO heavy duty, A1, SF)

I/O Card I
G = 6DI+4DO (6 x DI, 4 x DO)
B = 3BIO+2Arc (3 x BI/BO, 2 x Arc point sensor, T2, T3, T4)
C = F2BIO+1Arc (Fibre 2 x BI/BO, 1 x Arc loop sensor, T2, T3, T4)

I/O Card II
A = None
G = 6DI+4DO (6 x DI, 4 x DO)
H = 6DI+4DO (6 x DI, 4 x DO(NC))
I = 10DI (10 x DI)
I/O Card III
(1
1 = 3xI (5/1A) ringlug + Io (5/1A) for transformer differential protection

I/O Card IV
A = None

Option card I
A = None
D = 4Arc (4 x Arc sensor)
K = RS232 (RS232)

Future option
A = None

Analog measurement card (See application)


1 = 3L(5A) + 2Io (5/1A+1/0,2A) ringlug + 4U
2 = 3L(1A) + 2Io (5/1A+1/0.2A) ringlug + 4U
Communication interface I
A = None
B = RS232 (RS232, IRIG-B)
C = RS232+RJ (RS232, IRIG-B + Ethernet RJ-45 100 Mbs)
D = RS232+LC (RS232, IRIG-B + Ethernet LC 100 Mbs)
N 2xRJ (Ethernet RJ 100 Mbs, RSTP)
O = 2xLC (Ethernet LC 100 Mbs, RSTP)
P = PP (Plastic / Plastic serial fibre)
R = GG (Glass / Glass serial fibre)

Reserved
A = Reserved

Display type
B = 128x128 (128 x 128 LCD matrix)
(2
C = 128x128Ext (128 x 128 LCD matrix, detachable)

Nominal DI voltage (voltage withstand)


A = 24 Vdc/ac (255 Vdc/ac)
B = 110 Vdc/ac (255 Vdc/ac)
C = 220 Vdc/ac (255 Vdc/ac)

Product version
A = Version 2.1

Future option
A = None

Region
A = English, IEC
B = English, ANSI

1) 1) If slot 8 = 1 or 2, then slot 4 = 1


2) By default, the cable length is 2 m (6.56 ft). You can order cables of other
length separately: VX001-1 (1 m/3.28 ft), Vx001-3 (3 m/9.84 ft) or VX001-5 (5 m/
16.40 ft).
NOTE: All PCBA cards are conformally coated.