C8000 - Manual de Programação (En) (2006.06)
C8000 - Manual de Programação (En) (2006.06)
Regular Programming
- Press and hold Program for one second until
"PROG" shows in the display, followed by
"ENTER CODE"
- Enter code 1,2,3.
Special Programming
- Press and hold Program for five seconds until
"L-2" and "LEVEL 2", followed by,"SP PROG"
and "ENTER CODE" shows in the display.
- Enter code 1,2,3.
Information Mode
6/20/2006
"Filter Lockout" message does not clear
- Turn the fryer -OFF-
6/20/2006
Product Programming
-Press "Select Time" to view each product step, cook times for each step
can be changed by pressing switches below the display
-Press "Select Function" to select the item to program for each step: time,
temperature,alarms etc.
-When you are finished programming the selected product turn the
Keyswitch to the "Cook" position
Special Programming
-Press the Timer switch. This will put you into the Special
Program Mode. The display will read "SP".
(4) (3) (2) (1) -By pressing the corresponding switch below the digital
display the following selections can be made:
- (1) Erases all memory
- (2) Restores Henny Penny Cooking parameters.
- (3) Toggles selection between F for fahrenheit and C for Celsius
- (4) Toggles selection between E for electric or O for gas
6/20/2006
Basic Programming Sequence
-The password keystroke sequence must be performed to access
programming. Each switch must be pressed within one second of each
other when performing the password keystroke sequence.
Special Programming
-Enter the password keystroke sequence (refer to the "Basic Programming Sequence"
6/20/2006
Regular Programming
Special Programming
Information Mode
6/20/2006
Regular Programming
- Press and hold "SET and Temperature switch for at least five seconds.
A tone will sound, and the left display shows "F" and the right display
shows the set point temperature. The temperature LED and all product
LED's flash.
- Press the right UP and DOWN switches to program the temperature for all
products.
- Press the "SET" switch, the left display shows "Slct" and the right display
shows "Prod". The product LED also flashes.
- Press either the left or right UP and DOWN switches to select a product to
program, the corresponding LED will be lit.
- Pressing the SET switch allows you to scroll through and program Cook
Time, Hold Time, and Alarms,. Pressing the right UP and DOWN switches
allows you to adjust each setting.
- Press and hold the SET switch to exit program mode.
OR - Press and hold the right UP or DOWN switch for five seconds to initialize
all settings. Special Program Mode is automatically exited if initialize is
done.
- To perform the input/output test.
- While in Special Program Mode, press the set "SET" switch.
The left display shows "10" and the right display shows "test" and then goes blank.
- All pushbuttons can now be tested, when pressed each corresponding LED
should illuminate.
- The heating circuit can be tested by pressing the TEMP switch.
- To exit the Special Program Mode press and hold the SET switch.
6/20/2006
Product Programming (Low Level Program Mode)
- Press and hold "SET and Temperature switch for at least five seconds.
A tone will sound, and the left display shows "Slct" and the right display
shows "prod". The Product LED also flashes.
- Press either the left or right UP and DOWN switches to select a product to
program, the corresponding LED will be lit.
- Pressing the SET switch allows you to advance through and program
Cook Time, Hold Time, Temperature, and Alarms,. Pressing the right UP
and DOWN switches allows you to adjust each setting.
- Press and hold the SET switch to exit program mode.
- Turn Power Switch off, then press and hold the right UP and DOWN
switches while turning Power Switch back on.
- Once in the Special Program Mode, press the right Up and Down
switches to select Fahrenheit (F) or Celsius (C).
- Press and release the SET switch to advance through, Probe Calibration,
Timer Alarm Duration, and Hold Alarm Duration. Use the right UP and
DOWN switches to make any adjustments..
- Press the SET switch once more and the left display shows "init", and the
OR
right display shows "sys". Push and hold the right UP or DOWN switch for
five seconds to initialize all settings. Special Program Mode is
automatically exited if initialization is done.
- Press the SET once more and the left display shows "IO", and the right display
shows "test". All displays will go blank and by pressing all switches, enables all
LED's and displays.
- Pressing the TEMP switch turns on the heating circuit.
- Press and hold the the SET switch to exit Special Program Mode.
6/20/2006
Regular Programming
- Press and hold the FUNCTION button for two seconds "REG
PROGRAM" will show in the display, followed by "CODE".
- Press the Product button (1-0) that you would like to program.
- Press the SCAN button while in Time Mode of the first inerval
to program subsequent intervals. "INT 2" will flash on the left
side of the display . Now follow the regular programming
procedure.
- To exit programming press and hold the FUNCTION button
Factory Preset
- Press and hold the FUNCTION button for two seconds until
"REG PROGRAM" show's in the display. As soon as "REG
PROGRAM" shows in the display, press and release the
Function button 3 times until "FAC PRESET" shows in the
display.
6/20/2006