Figure 4.19-Fillet Weld Soundness Tests For WPS Qualification (See 4.11.2)
Figure 4.19-Fillet Weld Soundness Tests For WPS Qualification (See 4.11.2)
1 :2000 QUALIFICATION
y W 2 = MINIMUM MULTIPLE
PASS FILLET WELD
USED IN
Wl = MAXIMUM SINGLE
PASS FILLET WELD
USED IN
CONSTRUCTION CONSTRUCTION
MACROETCH TEST
SPECIMEN
INCHES MILLIMETERS
Weld Weld
Size T1 min* T2 min* Size T1 min* T2 min*
3/16 1/2 3/16 5 12 5
1/4 3/4 1/4 6 20 6
5/16 5/16 8 25 8
3/8 3/8 10 25 10
1/2 1/2 12 25 12
5/8 5/8 16 25 16
3/4 3/4 20 25 20
> 3/4 > 20 25 25
*Note: Where the maximum plate thickness used in production is less than the value shown in the table, the
maximum thickness of the production pieces may be substituted for T1 and T2.
Figure 4.19-Fillet Weld Soundness Tests for WPS Qualification (see 4.11.2)
130