0% found this document useful (0 votes)
41 views

Standalone Access Control: Packing List Wiring

This document provides instructions for installing a standalone access control system. It has a 2000 user capacity and supports access by card, card + PIN, or card/PIN. Key features include a zinc-alloy housing making it anti-vandal and explosion-proof. Installation involves removing the back cover, mounting it on an 86x86mm box, and connecting the wires according to the provided color code.

Uploaded by

Amine Aminou
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
41 views

Standalone Access Control: Packing List Wiring

This document provides instructions for installing a standalone access control system. It has a 2000 user capacity and supports access by card, card + PIN, or card/PIN. Key features include a zinc-alloy housing making it anti-vandal and explosion-proof. Installation involves removing the back cover, mounting it on an 86x86mm box, and connecting the wires according to the provided color code.

Uploaded by

Amine Aminou
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

Please read the user manual carefully before installation.

Packing List Wiring NO


White

Wire Color Function Notes Green

Standalone Access Control INTRODUCTION


Wall Anchors
Green NC Relay NC
NC

COM
Brown
Self Tapping Screws
This product is a contactless EM proximity card standalone access Brown COM Relay COM Black
GND
control. It adopts zinc-alloy case, anti-vandal and anti-explosion, White NO Relay NO Red
2,000 user capacity and supporting access by card, card + PIN, 1 2 3 DC+
Black GND Negative Pole Yellow
card or PIN. It can be installed on 86x86mm mount box. Admin Add Card Admin Delete Card
OPEN
4 5 6 Red DC+ 10-24V DC Power Input +
Admin Cards Exit Button -
7 8 9 Connect to Exit button and the
Yellow OPEN
Features and Benefits 0 # Exit button is connected to GND
Zinc-alloy housing, anti-vandal, anti-explosion
* Screw Driver

Waterproof, conforms to IP67 Sound and Light Indication


Diode 1N4004
User capacity: 2000 (For relay circuit protection) Operation Status Light Buzzer Common power supply
Length of PIN: 4 – 8 digits Stand by Red light bright Attention: Install a 1N4004 or equivalent diode is needed when use
Wide voltage input: DC 10-24V a common power supply, or the reader might be damaged.
Enter programming mode Red light shines
Supporting block enrollment with cards sequentially numbered (1N4004 is included in the packing).
INSTALLATION In the programming mode Orange light bright
1 2 3 Pulse Mode, Toggle Mode White
Can be installed on 86mm×86mm box, very easy to install Remove the back cover from the unit with screw. Open lock Green light bright One beep NO
Green
4 5 6 Admin can add/delete admin cards,
making add/delete cards rapidly.
Drill hole on the wall according to the back size of the machine Operation failed 3 beeps NC

and fix the back cover to the wall. (or fix the back cover firmly to COM
Brown

7 8 9 the 86cm×86cm box)


GND
Black

Specifications Thread the cable through cable hole, connect related cable. Factory Default settings and add admin cards
Red
0 #
* For the un-used cable please separate with insulating tape. Power off, press exit button, power on, release it until hear two DC+ 10-24V DC
Operating Voltage 10-24V DC After wiring, install front casing to the back casing and fix well. beeps. Swiping two cards, the first card is “Admin Add Card”, the Yellow
OPEN Power
Working Current ≤80mA second card is “Admin Delete Card”, then the device will be in Exit Button
Weatherproof IP67 standby mode. Resets to factory default setting and adding admin
cards are successful.
Read Range ≤6cm
If you don't need to add admin cards: Power off, press exit button, Add/Delete Users by Admin Card
User Capacity 2000
power on, release it until hear two beeps, and the orange LED turn Using Admin Cards to add delete card users
Card type EM Card on. Waiting for ten seconds, there is a beep and it will be in standby
WMK1-S-EM

40m m
Card Frequency 125KHz mode. Resets to factory default setting is successful. Step 1: Read Admin Add Card
Step 2: Read user cards
≤2A

80m m
Lock Output Load Reset to factory default, the users' information won't be deleted. Add users
(Repeat step 2 for additional user cards)
Operating Temperature -40°C~+70°C,(-40°F~158°F) 60mm Step 3: Read Admin Add Card again to end
Operating Humidity 10%~98%RH
Step 1: Read Admin Delete Card)
Dimensions L110xW76xH22mm(Wide) STANDALONE MODE Step 2: Read user cards
Delete users
Unit Weight 436g Connection Diagram (Repeat step 2 for additional user cards)
Shipping Weight 500g Step 3: Read Admin Delete Card again to end
User Manual Special Power Supply for access control system

1 2 3 4

Enter and Exit Program mode 2.When adding card users, an attached PIN 1234 will be added Access Mode Setting Users Setting
in automatically. This pin cannot used to open door. If you Programming Step Keystroke Combination LED
Programming Step Keystroke Combination
want to open door by card + PIN, you should first change the Change PIN
Enter Program Mode (Admin Code) #
Enter Program Mode * (Admin Code) # old PIN 1234, method referring to Change PIN.
Open door by card
*
40#
Red shines
Programming Step Keystroke Combination
(Factory default is 777777) 3. Before add the proximity cards sequentially numbered,
Exit Program Mode
* the ID number should be sequential and empty. OR
Orange bright
Change PIN which
attached to card users * (Read Card) (old PIN) # (New PIN) #
(Repeat New PIN) #
Open door by card + PIN 41#
For safety, the Admin must change the Admin code. Change independent
OR
Open door by card or PIN 4 2 # (Factory default) PIN * (ID number) # (old PIN) # (New PIN) #
(Repeat New PIN) #
Quick Start and Operation Modify Admin Code Delete Users by Keypad
Note: The PIN can be changed to any one 4-8 digits, but cannot
Quick Settings Programming Step Keystroke Combination LED Programming Step Keystroke Combination LED
Exit Program Mode
* Red bright
be ‘1234’, and the PIN attached to the card is only used for
Enter Program Mode (Admin Code) #
* - Admin Code - #
Then you can do the
Enter Program Mode
* (Admin Code) # Red shines * Red shines
Alarm Output Time Setting
card + PIN access mode.
Enter the Programming Mode 0 (New Admin Code) # Delete Card User-Common
programming (Repeat New Admin Code) # Orange bright Programming Step Keystroke Combination LED
Update Admin Code Delete Card - By Card 2 (Read Card) #
(Factory default is 777777) Enter Program Mode (Admin Code) #
(Admin Code is any 6 digits) OR
Delete Card - 2 (Input ID number) #
Orange bright
Set alarm time
* Red shines How to release the door
0 - New Code - # - Repeat Exit Program Mode Red bright 6(1-3) # Orange bright Open door by card (Read Card)
Change the Admin Code the New Code - # * By ID number Exit Program Mode Red bright
(New Code: any 6 digits)
The length of the admin code is 6 digits, the admin should keep it in
Delete All User 2 0000 # Orange bright * Open door by User PIN (Users PIN) #
mind. Note:1. Factory default is 1 minute. Open door by user card + PIN (Read Card) (Users PIN) #
Exit Program Mode Red bright
Add Card User
1 - Read Card - #
(Cards can be added in
* 2. Alarm output time includes: the alarm time of anti-vandal,
safe mode and closing reminder.
Add Users by Keypad (ID Number:1-2000)
continuously) 3. Swipe valid card or Input valid PIN can remove the alarm.
Programming Step Keystroke Combination LED
1- User ID - # - PIN- # Pulse Mode and Toggle Mode Setting
Add PIN User
(ID number:1-2000)
Enter Program Mode
Add Card User
* (Admin Code) # Red shines
Programming Step Keystroke Combination LED Set Safe Mode
2 - Read Card - # Enter Program Mode (Admin Code) # Programming Step Keystroke Combination LED
(for Card User)
Add card: by Card 1 (Read Card) # * Red shines
Enter Program Mode (Admin Code) #
Delete User
2 - User ID-#
OR Pulse Mode 3 (1-99) #
Orange bright
* Red shines
Add Card: by ID 1 (Input ID number) # Toggle Mode 30# Normal Mode 7 0 # (Factory default)
(for PIN User) number (Read Card) # OR
Orange bright Exit Program Mode Red bright
Exit from the Programming Mode
* OR * Lockout Mode 71# Orange bright
Add proximity cards 8 (ID number) # (8/10 Note: 1. Factory default is Pulse Mode and the access time is 5 OR
How to release the door sequentially numbered digits card number) # seconds. When set the access time to “0”, the device will be Alarm output Mode 72#
Open door by card (Read Card) (The number of cards)# in Toggle Mode.
Open door by User PIN (Users PIN) # 1 (ID Number) # 2. Pulse Mode: The door will be closed automatically after
Exit Program Mode
* Red bright
Add PIN users Orange bright Note: Lockout Mode: If swipe card/input PIN with invalid users for
Open door by user card + PIN (Read Card) (Users PIN) # (4-8 digits PIN) opening the door for a while. 10 times in 1 minute, the device will be lockout for 10 minutes.
Exit Program Mode
* Red bright 3. Toggle Mode: Under this mode, after opening the door, the
door won't be closed automatically until next valid user input.
When the device repowered, the lockout will be canceled.
Alarm Output Mode: If swipe card/input PIN with invalid
Note: 1. When swiping cards to add users, the user ID will be added
in automatically, and ID number will be from small to big, That is to say, whether open or close the door, you must users for 10 times in 1 minute, the buzzer built-in will be
ranged from 1 – 2000. swipe valid card or input valid PIN. activated.

5 6 7 8