0% found this document useful (0 votes)
186 views5 pages

13ID0009-Control System Architecture-R0

This document provides a summary of symbols, abbreviations, and line types used in a control system architecture diagram for a new sugar mill. It includes a table that defines symbols like DCS, OS, ES, and abbreviations like PCS, SIS, FGS. A legend section provides more details on interface types including Ethernet, Profibus, and RS485. The diagram then shows the control room network connected to a historian, servers, workstations and cabinets extending connectivity into the field via PROFINET, PROFIBUS and other interfaces.

Uploaded by

moddys
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
0% found this document useful (0 votes)
186 views5 pages

13ID0009-Control System Architecture-R0

This document provides a summary of symbols, abbreviations, and line types used in a control system architecture diagram for a new sugar mill. It includes a table that defines symbols like DCS, OS, ES, and abbreviations like PCS, SIS, FGS. A legend section provides more details on interface types including Ethernet, Profibus, and RS485. The diagram then shows the control room network connected to a historian, servers, workstations and cabinets extending connectivity into the field via PROFINET, PROFIBUS and other interfaces.

Uploaded by

moddys
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
You are on page 1/ 5

SYMBOL ABBREVIATION DESCRIPTION LINE TYPES ABBREVIATIONS

Electrical PCS Process Control System


OS Operator Station
SIS Safety Instrumented System
FO : Fiber Optic
ES Engineering Station FGS Fire & Gas System

OSS OS Server PMS Power Monitoring System


COLOUR CODES
Ethernet (PCN-T) AMS Asset Mgt System
Flat Panel 19” BAS Building Automation System
Ethernet (PCN-S)
DMS Danger Mgt System
PC Local PC – OS Client Ethernet (Safety Network)
PIMS Production Information Mgt System
Ethernet (PDN) LIMS Laboratory Information Mgt System
Ethernet (BAS)
PRN Printer
A4 A4 paper size PCN-T Process Control Network - Terminal
C Colour Ethernet (Quarantine)
PCN-S Process Control Network - System
B Black / White Ethernet (Perimeter)
PDN Production Data Network
I Inkjet
L Laser Profibus DP BSN Building Mgt & Security Network
Alm Alarm OIS Operator Interface Sub-System
Other electrical wiring
Rep Report EIS Engineer Interface Sub-System
Intrinsically Safe
Controller (Redundant)
DCS AS41x
DCS / SIS / FGS
INTERFACE TABLE LEGEND
IS I/O Intrinsically Safe I/O
1st Letter 2nd Letter 3rd Letter
Ethernet Modbus Single
IS F I/O Intrinsically Safe Failsafe I/O Profibus RS485 Redundant
Modbus DP
Non-IS I/O Non Intrinsically Safe I/O OPC
7 S7 Comms
F I/O Failsafe I/O
Example
Y-Link Profibus DP redundant to
SIS Interface Table
single converter
EMR DCS Process
EOR DCS nnn
B Intrinsically Safe barriers

Doc : QPB-W8130034_CSA Customer PT. Industri Gula Glenmore


Control System Architecture Sheet
0.0 31/05/13 HD Project New Sugar Mill 6000 Expandable 8000 TTH
LEGEND 1
rev date drawn ITB
Legend
Enterprise Network Control Desk

OWS

OWS EWS OWS EWS


S602 SERVER STATION CLIENT
CONTROL ROOM

HISTORIAN

IPC IPC IPC IPC

X 204-2 X 204-2
Rack Server A

PROFINET
D
X 204-2 X 204-2

MCC

Y-Link PROFIBUS

416H DCS

In Seperated Offer
PROFINET

X 204-2 X 204-2
System Cabinet 1

X 101-1 X 101-1 X 101-1 X 101-1 X 101-1 X 101-1 X 101-1 X 101-1 X 101-1 X 101-1
FIELD

IM 153-4 IM 153-4 IM 153-4 IM 153-4 IM 153-4


Remote I/O Remote I/O
Remote I/O Remote I/O Remote I/O
Juice Remote
Cane Prep. Mill. Evaporator
Heater Clarifier

Doc : QPB-W8130034_CSA Customer PT. Industri Gula Glenmore


Control System Architecture Sheet
0.0 31/05/13 HD Project New Sugar Mill 6000 Expandable 8000 TTH
2
rev date drawn ITB CCR & Mill Station
X 204-2 X 204-2
PROFINET
A B

MCC

Y-Link PROFIBUS
416H DCS
CONTROL ROOM

PROFINET In Seperated Offer

X 204-2 X 204-2

System Cabinet 2

X 101-1 X 101-1 X 101-1 X 101-1 X 101-1 X 101-1 X 101-1 X 101-1


FIELD

IM 153-4 IM 153-4 IM 153-4 IM 153-4


Remote I/O Remote I/O Remote I/O Remote I/O
Vacum Vacum Vacum Vacum
Pan A Pan B Pan C Pan R

Doc : QPB-W8130034_CSA Customer PT. Industri Gula Glenmore


Control System Architecture Sheet
0.0 31/05/13 HD Project New Sugar Mill 6000 Expandable 8000 TTH
3
rev date drawn ITB Vacuum Pan
X 204-2 X 204-2
PROFINET
B C

MCC

Y-Link PROFIBUS
416H DCS
X 204-2
CONTROL ROOM

PROFINET In Seperated Offer

X 204-2 X 204-2

System Cabinet 3

X 101-1 X 101-1 X 101-1 X 101-1 X 101-1 X 101-1


FIELD

IM 153-4 IM 153-4 IM 153-4

Remote I/O Remote I/O Remote I/O


CO2 Pump Carbonator Dry & Melter

Doc : QPB-W8130034_CSA Customer PT. Industri Gula Glenmore


Control System Architecture Sheet
0.0 31/05/13 HD Project New Sugar Mill 6000 Expandable 8000 TTH
4
rev date drawn ITB Final Product
X 204-2 X 204-2
PROFINET
C D

MCC

Y-Link PROFIBUS
416H DCS
X 204-2
CONTROL ROOM

PROFINET In Seperated Offer

X 204-2 X 204-2

System Cabinet 4

X 101-1 X 101-1 X 101-1 X 101-1 X 101-1 X 101-1


X 204-2
FIELD

IM 153-4 IM 153-4 IM 153-4


IM 153-4

Remote I/O Remote I/O Remote I/O Boiler Control


Pakan Ternak Pupukr Electrical (by Other)

Doc : QPB-W8130034_CSA Customer PT. Industri Gula Glenmore


Control System Architecture Sheet
0.0 31/05/13 HD Project New Sugar Mill 6000 Expandable 8000 TTH
5
rev date drawn ITB Utility