REPUBLIC 

OF THE 
PHILIPPINES
OFFICE OF THE BUILDING 
OFFICIAL

SOLANO, NUEVA VIZCAYA
SITE

1 VICINITY MAP & STREET VIEW , Source ‐ Google Maps LAND USE & ZONING


A1 NOT TO SCALE

ARCHITECTURAL

A1 ‐  PERSPECTIVES, SITE DEV., VICINITY 1
A2  ‐ FLOOR PLANS 2
A3  ‐  DOORS, WINDOWS, GATE SCHEDULE 3 LINE & GRADE

BUI EXIST A4  ‐  BUILDING ELEVATIONS 4


LDI
 

ING
6m

A5  ‐  BUILSING SECTIONS 5
N25the s NGS (re  
P.L.
 5.0

° 44ite p fer to
'E , lan)  
,
'W 

6.7 STRUCTURAL
9m
° 42

 
N63

S1  ‐  FOUNDATION PLAN, C1‐F1, TIE BEAM SCHED. 6
P.L.
S2  ‐  C1‐F2, WALL FRAME DETAILS 7 ARCHITECTURAL

Y

S3  ‐  LEVEL 2 FLOOR BEAM LAYOUT, BEAM DETAILS 8
A

P.L.
83
F W

S2 3
 , 4.
HT O

° 46 S4  ‐  ROOF DECK BEAM LAYOUT, SLAB DETAILS 9
RI G

'W
'E

 , 7. S5  ‐  STAIR DETAILS 10
° 47

SIDE
 W A 06 m S6  ‐  ROOF DETAILS @ LEVEL 2 11
S6 6

LK ( P.L
s ew 0.97 . S7  ‐  ROOF DETAILS @ ROOF DECK 12
er b  m
elow
) S8  ‐  RAFTER CONNECTION DETAILS 13
STRUCTURAL
ALK

BIN PLUMBING
IDEW

ACA

DS

STR P1 ‐ SANITARY LAYOUT, WATER DISTRIBUTION LAYOUT 14


AV E

E
AY

ET
F W

P2 ‐ SEPTIC VAULT DETAILS (EXISTING) 15
UNP

T O
IGH

ELECTRICAL
OAD

D R

PLUMBING AND SANITARY
ROA
ED R

LIC 
PAV

E1  ‐  POWER LAYOUT, LIGHTING LAYOUT 16
PUB

E2  ‐  ELECTRICAL LOADS, RISER DIAGRAM 17

2 SITE DEVELOPMENT 3 PERSPECTIVES 4 TABLE OF CONTENTS


A1 1 : 150 A1 1 : 100 A1 MECHANICAL
ENGINEERING PROJECT TITLE :  SHEET CONTENT  : REVISION APPROVED BY : SHEET NO.

DRAFTING:   BLAS G. ANQUILIANO III
2 ‐ Storey Residential Bldg. Site Development Plan,
with Partial Roof Deck for
Laundry Area
Vicinity Map, Street
View, Perspective,
3D VISUALIZER: BLAS G. ANQUILIANO III Jenzen Carl A. Agpalo A1
O W N E R  /  S
PTR NO. : DATE ISSUED: Table of Contents DATE:
PRC ID: VALID TIL : LOC.: BINACAO ST., BRGY. ROXAS, SOLANO, NUEVA VIZCAYA DATE APPROVED: SHEET 1 OF 17
A 2 B C A 2 B C
A5 A5

5.86 m
3.21 m 2.65 m 5.86 m

1.53 m 1.15 m 3.21 m 2.65 m

2
1 S5
F I R E W A L L S5
1 1 F I R E W A L L
1.63 m

PROPERTY LN.
UP UP

2.05 m
T&B SEE STAIR 

1.72 m
W2 PLANS
D3

2.99 m
STORAGE 
3 AREA 3 W1
A5 A5
4.75 m

4.75 m
RIGHT OF WAY

4.56 m
4.56 m
D2 D2

0.88 m
D1 DN.
KITCHEN/DINING
BED ROOM
3.11 m

BED ROOM

2.83 m

2.70 m
LIVING G2 2 1 D2
TRI‐CYCLE

1.57 m
AREA W1 W1 BALCONY
PORT

2 W1 2 W1
0.31 m

PROPERTY LN. G1

ENTRY 2.16 m 1.91 m 1.98 m


3.41 m 2.67 m 0.98 m 3.38 m 2.67 m
7.06 m 6.04 m

1 Level 1 FLOOR PLAN 2 Level 2 FLOOR PLAN
A2 1 : 100 A2 1 : 100

ARCHITECTURAL ENGINEERING PROJECT TITLE :  SHEET CONTENT  : PREPARED BY: APPROVED BY : SHEET NO.

2 ‐ Storey Residential Bldg. with Level 1 Floor Plan, DRAFTED BY: BLAS G. ANQUILIANO III

Partial Roof Deck for Laundry
Area
Level 2 Floor Plan
3D VISUALIZATION: BLAS G. ANQUILIANO III
Jenzen Carl A. Agpalo A2
CHECKED BY: ENGR. C. S. LEJANO O W N E R / S
PTR NO. : DATE ISSUED: PTR NO. : DATE ISSUED:
PRC ID : VALID TIL: PRC ID : VALID TIL: LOC.: BINACAO ST., BRGY. ROXAS, SOLANO, N.V. DATE APPROVED: DATE APPROVED: SHEET 2 OF  17
2" x 4" C‐PURLINS 
HORIZONTAL  PANELS  2.07 m 10Ømm  PLAIN BAR, 
SPACED @ 0.10m HORIZONTAL GRILLES  1.94 m
SPACED @ 0.15m
2" x 4" TUBULAR 
MAIN FRAME 2" x 2" TUBULAR, 
VERTICAL RAILS SPACE AS 

2.40 m

2.40 m

1.80 m

1.80 m
SHOWN

A B C 50mm Ø HEAVY  3D VIEW 2" x 5" LONG FLAT BARS  3D VIEW


DUTY GATE HINGE FOR MOUNTINGS
FRONT GATE G1 GRILLES G2
5.86 m GATE & GRILLE SCHEDULE
2
3.21 m 2.65 m A3 1 : 70
2.20 m 1.92 m 0.90 m 0.75 m 0.65 m

1 F I R E W A L L
1.10 m

DN.
2.25 m

2.01 m

2.10 m

2.10 m
2.10 m
1.02 m
92°
LAUNDRY & DRYING AREA D3
(OPEN AT FRONT AND ABOVE)
4.75 m

4.57 m
ROOF LN.
DOOR MARK:D3

2.57 m
2.50 m

DOOR MARK:D1 DOOR MARK:D2
SEE ROOF PLAN DOOR JAMBS:PRE‐FABRICATED PVC
DOOR JAMBS:1 3/4" x 5 1/2" MILINA DOOR JAMBS:1 3/4" x 5 1/2" MILINA
DOOR PANEL: PRE‐FAB. PVC DOOR  PANEL 
DOOR PANEL: 1 3/4" THK MILINA DOOR PANEL: 1 3/4" THK MILINA
W/ LOUVRES
2 NO. PIECES: 1 NO. PIECES: 3
NO. PIECES: 2
3 DOOR SCHEDULE
A3 1 : 80
5.81 m
1.20 m
0.60 m

0.40 m
1.20 m
ROOF DECK LAUNDRY WINDOW MARK: W1 WINDOW MARK: W5
1
A3 WINDOW TYPE: SLIDING WINDOW WINDOW TYPE: AWNING WINDOW
1 : 100
WINDOW MATERIAL: ALUMINUM WINDOW MATERIAL: ALUMINUM
GLASS: TINTED GLASS: TINTED
SILL HEIGHT: 0.6m ABOVE FFL SILL HEIGHT: 1.65m ABOVE T&B FLOORS
NO. OF PIECES: 4 NO. OF PIECES: 1

4 WINDOW SCHEDULE
A3 1 : 80
ARCHITECTURAL ENGINEERING PROJECT TITLE :  SHEET CONTENT  : PREPARED BY: APPROVED BY : SHEET NO.

2 ‐ Storey Residential Bldg. with Level 2, Gate & DRAFTED BY: BLAS G. ANQUILIANO III

Partial Roof Deck for Laundry
Area
Grilles Schedule,
Door & Window
Schedule
3D VISUALIZATION: BLAS G. ANQUILIANO III
Jenzen Carl A. Agpalo A3
CHECKED BY: ENGR. C. S. LEJANO O W N E R / S
PTR NO. : DATE ISSUED: PTR NO. : DATE ISSUED:
PRC ID : VALID TIL: PRC ID : VALID TIL: LOC.: BINACAO ST., BRGY. ROXAS, SOLANO, N.V. DATE APPROVED: DATE APPROVED: SHEET 3 OF  17
A B C 2 1 C B A

0.34 m

0.75 m
0.75 m

APEX OF FIRE WALL APEX OF FIRE WALL APEX OF FIRE WALL


APEX ROOF LINE APEX ROOF LINE
TOP OF BEAM TOP OF BEAM TOP OF BEAM

0.35 m

0.35 m
0.35 m

2.48 m
2.48 m
2.48 m

3.45 m
3.45 m

2.70 m
2.35 m

2.35 m
2.35 m

ROOF LINE ROOF LINE

0.63 m
TOP OF BEAM TOP OF BEAM TOP OF BEAM

0.40 m

0.40 m
0.40 m

3.43 m
3.43 m

9.55 m

9.55 m
9.55 m

2.80 m

2.80 m

2.80 m
2.80 m

9.21 m

2.40 m

2.40 m
2.40 m

TOP OF BEAM TOP OF BEAM TOP OF BEAM

0.40 m

0.40 m
0.40 m

3.15 m
3.30 m

3.30 m

3.30 m
3.30 m

3.30 m

2.70 m

2.70 m
2.70 m

GARAGE FLOOR 
GARAGE 
2" BELOW FFL
FLOOR 2" 

0.20 m
FFL

0.20 m
0.20 m

FFL 0.15 m FFL


NGL NGL BELOW FFL NGL NGL NGL
0.14 m

1 FACADE 2 RIGHT SIDE ELEVATION 3 REAR ELEVATION


A4 1 : 100 A4 1 : 100 A4 1 : 100

ARCHITECTURAL ENGINEERING PROJECT TITLE :  SHEET CONTENT  : PREPARED BY: APPROVED BY : SHEET NO.

2 ‐ Storey Residential Bldg. with Facade, Right Side DRAFTED BY: BLAS G. ANQUILIANO III

Partial Roof Deck for Laundry
Area
Elevation, Rear Side
Elevation
3D VISUALIZATION: BLAS G. ANQUILIANO III
Jenzen Carl A. Agpalo A4
CHECKED BY: ENGR. C. S. LEJANO O W N E R / S
PTR NO. : DATE ISSUED: PTR NO. : DATE ISSUED:
PRC ID : VALID TIL: PRC ID : VALID TIL: LOC.: BINACAO ST., BRGY. ROXAS, SOLANO, N.V. DATE APPROVED: DATE APPROVED: SHEET 4 OF  17
1 2 1 2 A B C

0.34 m
0.34 m
0.75 m

APEX OF FIRE WALL TOP OF FIREWALL TOP OF FIREWALL


APEX ROOF LINE

0.75 m
0.75 m
APEX ROOF LINE APEX ROOF LINE
TOP OF BEAM TOP OF BEAM SEE ROOF PLAN TOP OF BEAM SEE ROOF PLAN
0.35 m

2.48 m

2.48 m
3.11 m

2.70 m
2.70 m
2.35 m

LAUNDR DECK
ROOF LINE ROOF LINE
TOP OF BEAM TOP OF BEAM SEE ROOF PLAN SEE ROOF PLAN
TOP OF BEAM
0.40 m
9.55 m

9.55 m

9.55 m
2.80 m

2.80 m

2.80 m
9.21 m

9.21 m

9.21 m
2.40 m

LEVEL 2

6.73 m

6.73 m
TOP OF BEAM TOP OF BEAM
TOP OF BEAM
0.40 m

T&B FLOOR 

3.10 m

3.10 m
3.30 m
2.70 m

LN. @ 2" 
T&B LEVEL 1 TRICYCLE PORT
BELOW FFL

FFL
2.00 m 0.20 m

2.00 m 0.20 m
FFL NGL FFL
NGL NGL NGL
WF1
0.20 m

WF1 WF1

TIE BEAM TIE BEAM TIE BEAM


1 LEFT SIDE ELEVATION C1‐F1 C1‐F2 C1‐F1 C1‐F1
A5 1 : 100

2 SECTION 1 3 SECTION 2
A5 1 : 100 A5 1 : 100

ARCHITECTURAL ENGINEERING PROJECT TITLE :  SHEET CONTENT  : PREPARED BY: APPROVED BY : SHEET NO.

2 ‐ Storey Residential Bldg. with Left Side Elevation, DRAFTED BY: BLAS G. ANQUILIANO III

Partial Roof Deck for Laundry
Area
Building Sections
3D VISUALIZATION: BLAS G. ANQUILIANO III
Jenzen Carl A. Agpalo A5
CHECKED BY: ENGR. C. S. LEJANO O W N E R / S
PTR NO. : DATE ISSUED: PTR NO. : DATE ISSUED:
PRC ID : VALID TIL: PRC ID : VALID TIL: LOC.: BINACAO ST., BRGY. ROXAS, SOLANO, N.V. DATE APPROVED: DATE APPROVED: SHEET 5 OF  17
GENERAL NOTES 
TO LEVEL 2
1. ALL ELECTRICAL WORKS AND INSTALLATION SHALL  COMPLY WITH THE 
PROVISIONSOF THE LATEST EDITION OF THE PHILIPPINE ELECTRICAL CODE  2W
WP DN.
WITH THE RESULTS AND REGULATIONS OF THE NATIONAL BUILDING CODE AND 
LOCAL AUTHORITIES CONCERNED IN THE ENFORCEMENT OF ELECTRICAL LAWS 
6 5
AND REGULATION OF THE UTILITY COMPANIES CONCERNED.

2. SERVICE VOLTAGE TO THE BUILDING SHALL BE 110 / 220 VOLTS 60 
hertz,SINGLE PHASE

3. ALL INSTALLATION SHALL BE CONCEALED FROM VIEW. WIRING SHALL BE IN 
CASE IN POLYVINYL CHLORIDE (PVC) PIPE SCHEDULE.

4.MINIMUM WIRE CONDUIT SIZE SHALL BE 3.5mm ( No. 12 AWG TW) AND 
3 ROOF DECK LAUNDRY POWER LAY‐OUT 7 ROOF DECK LAUNDRY LIGHTNING LAY‐OUT
15mm PVC.TRADE SIZE, RESPECTIVELY UNLESS OTHERWISE SPECIFIED.
E1 1 : 100 E1 1 : 100
5.PULL BOXES OF APPROPRIATE SIZE SHALL BE PROVIDED, EVEN IF NOT 
INDICATED IN DRAWINGS TO ACCOMODATE THE NUMBER OF SPLICES OF 
WIRES.
UP 2W UP
TO LEVEL 1
6.ALL MATERIALS TO BE USED SHALL BE NEW AND APPROVED TYPE 
APPROPRIATE FORBOTH LOCATION AND INTENDED USE. TO  LAUNDRY DECK

7. ALL INSTALLATION SHALL BE DONE IN A WORKMANLIKE MANNER AND SHALL  DN. 2W DN.


INCLUDE ALL NECESSARY WORKS THAT MAY NOT BE CLEARLY INDICATED IN 
THE PLANS OR SCHEMATIC BUT NECESSARY TO ATTAIN THE PURPOSE OR 
INTENT OF THE DESIGN SCHEME. 4
2
8.MOUNTING HEIGHTS OF DEVICES FROM FINISHED FLOOR LINE MUST BE AS 
FOLLOWS :
2 Level 2 POWER LAY‐OUT 6 Level 2 LIGHTNING LAY‐OUT
E1 1 : 100 E1 1 : 100
a) 0.35m FOR CONVENIENCE OUTLET (0.15m ABOVE COUNTER)
b) 1.35 FOR WALL MOUNTED SWITCHES SINGLE POLE SWITCH TO LEVEL 2
CIRCUIT HOMERUN / CALLOUT
c) 1.37m FOR PANEL BOARDS
DOUBLE POLE SWITCH UP
THHN WIRE 2W
9.ELECTRICAL INSTALLATION SHALL BE UNDER THE DIRECT SUPERVISION OF 
2W
DOUBLE POLE SWITCH
DULY LICENSED ELECTRICAL ENGINEER, OR A REGISTERED MASTER 
GENERAL POWER OUTLET
REF
ELECTRICIAN.
TRIPLE SWITCH POLE
WP REFRIGERATOR OUTLET
REF 7
WEATHER PROOF OUTLET 1
3
GENERAL LIGHTING OUTLET

PANEL BOX
LEGENDS Level 1 POWER LAY‐OUT Level 1 LIGHTNING LAY‐OUT
4 1 5
E1 E1 1 : 100 E1 1 : 100
ARCHITECTURAL ENGINEERING PROJECT TITLE :  SHEET CONTENT  : PREPARED BY: APPROVED BY : SHEET NO.

2 ‐ Storey Residential Bldg. with Power Lay‐out, DRAFTED BY: BLAS G. ANQUILIANO III

Partial Roof Deck for Laundry
Area
Lightning Lay‐out,
General notes on
Electrical Plans,
3D VISUALIZATION: BLAS G. ANQUILIANO III
Jenzen Carl A. Agpalo E1
CHECKED BY: ENGR. C. S. LEJANO O W N E R / S
PTR NO. : DATE ISSUED: PTR NO. : DATE ISSUED: Electrical Legends
PRC ID : VALID TIL: PRC ID : VALID TIL: LOC.: BINACAO ST., BRGY. ROXAS, SOLANO, N.V. DATE APPROVED: DATE APPROVED: SHEET 16 OF  17
CIRCUIT  LOAD DESCRIPTION No. OF  CIRCUIT  WIRE SIZE & 
VOLTS WATTS AMPS
No. OUTLETS PROTECTION CONDUITS M
1 POWER OUTLET 2 220 600 2.72 30 AMPS 2 ‐3.5mm2 THHN FD 20mm PVC
1 ‐2.0mm2 FOR GROUND 100 AT
2 POWER OUTLET 4 220 1200 5.45 20 AMPS 2 ‐3.5mm2 THHN FD 20mm PVC
1 ‐2.0mm2 FOR GROUND
30 A 20 A
1 2
3 LIGHTING OUTLET 3 220 300 1.36 20 AMPS 2 ‐3.5mm2 THHN FD 20mm PVC
1 ‐2.0mm2 FOR GROUND 20 A 20 A
3 4
20 A 30 A
4 LIGHTING OUTLET 4 220 400 1.81 20 AMPS 2 ‐3.5mm2 THHN FD 20mm PVC 5 6
1 ‐2.0mm2 FOR GROUND
30 A 20 A
7 8
5 LIGHTING OUTLET 2 220 200 0.90 20 AMPS 2 ‐3.5mm2 THHN FD 20mm PVC 30 A
1 ‐2.0mm2 FOR GROUND 9

6 WASHING MACHINE 1 220 600 2.72 30 AMPS 2 ‐3.5mm2 THHN FD 20mm PVC


1 ‐2.0mm2 FOR GROUND

GROUNDING WIRE
7 REFRIGIRATOR 1 220 800 3.63 30 AMPS 2 ‐5.5mm2 THHN FD 20mm PVC
1 ‐3.5mm2 FOR GROUND 3 RISER DIAGRAM
E2 N.T.S.
8 SPARE 1 220 2400 10.9 20 AMPS 2 ‐3.5mm2 THHN FD 20mm PVC
1 ‐2.0mm2 FOR GROUND LINE SIDE LOAD SIDE
SERVIC
E DROP

9 SPARE 1 220 2400 10.9 30 AMPS 2 ‐5.5mm2 THHN FD 20mm PVC


1 ‐3.5mm2 FOR GROUND ENTRANCE CAP
STANDARD CLEARANCE OF 
ENTRANCE CAP:
TOTAL 8900 40.39
3.05m ‐ ABOVE SIDE WALK RIGID STEEL CONDUITS

HEIGHT VARIES
LOAD COMPUTATION:
DEMAND FACTOR (FC) = 80% 3.70m ‐ ABOVE RESIDENTIAL 
DRIVEWAY M WATT HOUR METER
I = (40.39 x 80%) + (8.00 X 0.25) DESIGN ANALYSIS: LIGHTNING & POWER 
I = 34.312 OVERALL FLOOR AREA = 68.67 m2 5.50m ‐ ABOVE DRIVEWAYS, ALLEYS  PANEL BOARD @ 
ENTRANCE ELL 1.40m ABOVE 
& PUBLIC ROADS

1.40 m
MAIN CIRCUIT BREAKER 68.67 m2 x 24 W per m2 = 1648.08 W FINISHED FLOOR
‐ USE 100AF 2P 100AT 220V 24 KAIC ENCLOSURE 7.30m ‐ ABOVE NATIONAL HIGHWAYSPROPERTY LINE
FIRST 3000 W @ 100% =3000 W
GROUNDING 
MAIN SERVICE CONDUCTOR RAMAINING 1648.08W @ 35% =576.82 W
WIRE
‐ USE 2‐32mm2 THHN COPPER CONDUCTOR 1 LAUNDRY MACHINE = 1500 W
‐ USE 1‐8mm2 FOR GROUND IN 32mm PVC CONDUCTOR TOTAL 5076.82 W
1 ELECTRICAL LOADS 2 SERVICE ENTRY DIAGRAM
E2 1 : 100 E2 N.T.S.
ARCHITECTURAL ENGINEERING PROJECT TITLE :  SHEET CONTENT  : PREPARED BY: APPROVED BY : SHEET NO.

2 ‐ Storey Residential Bldg. with Electrical Loads, DRAFTED BY: BLAS G. ANQUILIANO III

Partial Roof Deck for Laundry
Area
Service Entry Details,
Riser Diagram
3D VISUALIZATION: BLAS G. ANQUILIANO III
Jenzen Carl A. Agpalo E2
CHECKED BY: ENGR. C. S. LEJANO O W N E R / S
PTR NO. : DATE ISSUED: PTR NO. : DATE ISSUED:
PRC ID : VALID TIL: PRC ID : VALID TIL: LOC.: BINACAO ST., BRGY. ROXAS, SOLANO, N.V. DATE APPROVED: DATE APPROVED: SHEET 17 OF  17
TO LEVEL 1
WATER SUPPLY TO LAUNDRY DECK 1 1/2" Ø PVC WATER SUPPLY TO LAUNDRY DECK
VERTICAL DRAINAGE PIPE ( VENT PIPE) 3" Ø PVC VERTICAL DRAINAGE PIPE ( VENT PIPE)
CO
FD DN.
FAU UP HB DN.
FD WC
3" Ø PVC DRAINAGE PIPE
1 1/2"ØPVC WATER 
SUPPLY PIPE 
LAV
TO WATER SOURCE

3"Ø DS 3"Ø DS 3"Ø DS

3 SANITARY LAYOUT @ ROOF LAUNDRY DECK
P1 1 : 100 WATER DISTRIBUTION LAY‐OUT @ LEVEL 1 WATER DISTRIBUTION LAY‐OUT @ LAUNDRY DECK
4 5
P1 1 : 100 P1 1 : 100
3" Ø PVC VERTICAL DRAINAGE PIPE ( VENT PIPE)

UP
APEX ROOF

DN.

VENT PIPE
FD
3" Ø PVC DRAINAGE PIPE DS LAUNDRY DECK
TO DOWN SPOUT
DS DS DS
2 SANITARY LAY‐OUT @ LEVEL 2 CO DS
P1 FD FD
1 : 100
TO SEPTIC TANK (existing)
4" SOIL PIPE/WASTE PIPE TO LAUNDRY DECK ( VENT PIPE) DS LEVEL 2

UP
FD
FDLAV
WC TO H
2O S
O U RC
E LEVEL 1
LAV CO 3" Ø PVC DRAINAGE PIPE

LA
TO S FD
FD EPTI FAU V TO S
C TA TREE
T SE
N K FD LAV WER
WC
DS 3" Ø PVC DRAINAGE PIPE DS DS CO
TO STREET SEWERS

1 SANITARY LAY‐OUT @ LEVEL 1 6 SANITARY LAY‐OUT ISO DIAGRAM
P1 1 : 100 P1 N.T.S
ARCHITECTURAL ENGINEERING PROJECT TITLE :  SHEET CONTENT  : PREPARED BY: APPROVED BY : SHEET NO.

2 ‐ Storey Residential Bldg. with Sanitary Lay‐out. DRAFTED BY: BLAS G. ANQUILIANO III

Partial Roof Deck for Laundry
Area
Water Distribution
Lay‐out, Isometric
Diagram
3D VISUALIZATION: BLAS G. ANQUILIANO III
Jenzen Carl A. Agpalo P1
CHECKED BY: ENGR. C. S. LEJANO O W N E R / S
PTR NO. : DATE ISSUED: PTR NO. : DATE ISSUED:
PRC ID : VALID TIL: PRC ID : VALID TIL: LOC.: BINACAO ST., BRGY. ROXAS, SOLANO, N.V. DATE APPROVED: DATE APPROVED: SHEET 14 OF  17
3.15 m
1.00 m 2.15 m
Ø10mm RSB BOTHWAYS AS SHOWN

Ø10mm RSB SAG RODS

4" THK CONC. SLAB W/ CEM. PLASTER

HH HH

2.10 m
OUTLET PIPE HH
INLET PIPE

HANDHOLE (TYPICAL)

GENERAL NOTES:
3.15 m 1. ALL PLUMBING WORKS SHALL BE DONE IN ACCORDANCE WITH LATEST 
1.00 m 2.15 m NATIONAL  PLUMBING CODE OF THE PHILIPPINES.
Ø10mm RSB BOTHWAYS
2. ALL SLOPE SHALL MAINTAIN A MINIMUM F 2% FOR HORIZONTAL BRANCHES
4" THK CHB AND SEWAGE MAIN LINE/DRAINAGE LINE.
Ø100mm SANITARY TEE
3. ALL FIXTURES SHALL BE VENTED UNLESS OTHERWISE INDICATED. MAIN VENT 
STACK SHALL  TERMINATE 150mm ABOVE ROOF LINE.
2.10 m

OUTLET PIPE LEACHING  DIGESTION  INLET PIPE


CHAMBER CHAMBER
1/2" CEM. PLASTER FINISH 4. ALL WATER SUPPLY INDIVIDUAL BRANCHES TO FIXTURES SHALL BE PROVIDED 
TITH 300mm  AIR CHAMBER.

5.ALL MATERIALS TO BE FURNISHED AND USED SHALL BE BRAND NEW. FREE FROM 
DAMAGES
HAND HOLE Ø10mm RSB BOTHWAYS AND IMPERFECTIONS. (STANDARD)

MAN HOLE MAN HOLE LEGENDS:


6. ALL PLUMBING WORKS SHALL BE UNDER THE SUPERVISION OF A REGISTERED 

0.10 m
OUTLET  FAU ‐ FAUCET
MASTER  PLUMBER. CO ‐ CLEAN OUT
PIPE AIR CHAMBER INLET PIPE LAV ‐ LAVATORY FD ‐ FLOOR DRAIN
WC ‐ WATER CLOSET DS ‐ DOWN SPOUTS
4" WASTE PIPE
1.90 m

LEACHING  DIGESTION 

1.80 m
2.10 m

2.10 m
CHAMBER CHAMBER
CONCRETE SLAB FLOOR
0.20 m

0.20 m

3 ‐ Ø10mm LONGITUDINAL 
0.10 m

RSB Ø10mm RSB  
3 ‐ Ø10mm RSB @ 0.30m  0.40 m 0.55 m 1.15 m 1.05 m @ 0.45m O.C. 
O.C. 3.15 m B.W.

1 SEPTIC VAULT DETAIL (EXISTING STRUCTURE)
P2 1 : 50
ARCHITECTURAL ENGINEERING PROJECT TITLE :  SHEET CONTENT  : PREPARED BY: APPROVED BY : SHEET NO.

2 ‐ Storey Residential Bldg. with Septic Vault Details, DRAFTED BY: BLAS G. ANQUILIANO III

Partial Roof Deck for Laundry
Area
General Notes on
Plumbing Plans
3D VISUALIZATION: BLAS G. ANQUILIANO III
Jenzen Carl A. Agpalo P2
CHECKED BY: ENGR. C. S. LEJANO O W N E R / S
PTR NO. : DATE ISSUED: PTR NO. : DATE ISSUED:
PRC ID : VALID TIL: PRC ID : VALID TIL: LOC.: BINACAO ST., BRGY. ROXAS, SOLANO, N.V. DATE APPROVED: DATE APPROVED: SHEET 15 OF  17
2.00 m
9 ‐ 16mm Ø FOOTING REINFORCEMENT 
0.30 m
SPACED AS SHOWN,
10mm Ø RSB STIRRUPS 0.10 m
TIED WITH #16 G.I. TIE WIRE
38mm CONC. COVER

SEE COLUMN  C1
2 ‐ 20mm Ø RSB (C1) 
SCHEDULE
2 ‐ 20mm Ø RSB

0.40 m
9 ‐ 16mm Ø 
A B C 2 ‐ 20mm Ø RSB
FOOTING 

2.00 m
REINFORCEMENT 
SPACED AS SHOWN,
2 ‐ 20mm Ø RSB
TIED WITH #16 G.I. 
5.86 m TIE WIRE

1.53 m 1.68 m 2.65 m 2 C1 SCHEDULE


S1 1 : 10

0.10 m
1 TB TB
C1‐F1 PLAN
1.68 m

SEE TIE BEAM DETAILS 3

1.73 m
C1‐F2 S1
WF2

SEE WALL FOOTING  C1‐F1 1 : 30


DETAILS
WF1

4.56 m
10mmØ TEMP.  TB
RSB SPACED @  TB WF1 TB
0.40m ON 
3.06 m

PROPERTY 

2.83 m
CENTER
C1‐F2 LINE
C1‐F1
TB
2 TB
8 ‐ 20mm Ø VERTICAL RSB

0.90 m
(SEE C1 SCHEDULE)
2.53 m BACK FILL
38mm THK 
3.15 m 2.67 m CONCRETE 
10mmØ RSB STIRRUPS 
5.81 m COVERING

2.10 m
10mm Ø RSB COLUMN TIES  2 ‐ 16mmØ RSB 
SPACED @ [email protected], 3@ SEE TIE BEAM SCHEDULE
0.10m,  [email protected], REST @ 

0.35 m
GRAVEL BED
1 Level 1 FOUNDATION PLAN 0.20m
BACK FILL
S1 1 : 100
4 ‐ 16mmØ RSB 

0.40 m
9 ‐ 16mm Ø FOOTING 
REINFORCEMENT SPACED @ 
0.20m, O.C, B.W. GRAVEL BED

0.10 m
0.25 m
2.00 m

4 C1‐F1 DETAILS 5 BEAM SCHEDULE (TIE BEAM)
S1 1 : 30 S1 1 : 10

ARCHITECTURAL ENGINEERING PROJECT TITLE :  SHEET CONTENT  : PREPARED BY: APPROVED BY : SHEET NO.

2 ‐ Storey Residential Bldg. with Foundation Plan, DRAFTED BY: BLAS G. ANQUILIANO III

Partial Roof Deck for Laundry
Area
C1‐F2 Details, Tie
Beam Schedule
3D VISUALIZATION: BLAS G. ANQUILIANO III
Jenzen Carl A. Agpalo S1
CHECKED BY: ENGR. C. S. LEJANO O W N E R / S
PTR NO. : DATE ISSUED: PTR NO. : DATE ISSUED:
PRC ID : VALID TIL: PRC ID : VALID TIL: LOC.: BINACAO ST., BRGY. ROXAS, SOLANO, N.V. DATE APPROVED: DATE APPROVED: SHEET 6 OF  17
4.00 m
0.10 m SEE COLUMN (C1)  10mm Ø VERT. BARS 
SCHEDULE SPACED @  0.80m O.C.  100mm THK SLAB 100mm THK SLAB
W/ ALTERNATE BENDS 10mm Ø VERT. BARS 

0.10 m
10mm Ø TEMP. 
10mm Ø EVERY THIRD LAYER  BARS SPACED @  SPACED @  0.80m O.C.  10mm Ø TEMP. 
HOR. BARS 0.50m BOTHWAYS  W/ ALTERNATE BENDS BARS SPACED 
C1 C1 @ 0.50m 
(TYPICAL) 10mm Ø EVERY THIRD 
BOTHWAYS 
6" THK CHB LAYER HOR. BARS
(TYPICAL)
6" THK CHB
18 ‐ 16mm Ø FOOTING  FINISH FLOOR LINE FFL

0.20 m
REINFORCEMENT  TRICYCLE PORT FLOOR LN.
GRAVEL BEDDING GRAVEL BEDDING
SPACED AS SHOWN,
2.00 m

FINISH GROUND

0.10 m 0.48 m
GRAVEL BEDDING
TIED WITH #16 G.I. TIE  BACK FILL

0.58 m
BACK FILL
WIRE

0.20 m
SEE WALL FRAME‐

VERIFY ON SITE
BACK FILL BACK FILL
FOOTING PLAN

0.90 m
GRAVEL BEDDING

1.00 m
0.45 m
SEE TIE BEAM 
SCHEDULE
WF1  DETAILS
GRAVEL BEDDING

0.10 m
9 ‐ 16mm Ø FOOTING REINFORCEMENT SPACED AS SHOWN,
TIED WITH #16 G.I. TIE WIRE
1 C1‐F2 PLAN
S2
TIE BEAM TO WALL FRAME DETAIL
1 : 30
SEE COLUMN GRIDS

0.45 m
4" THK CHB W/ 10mm Ø RSB 
8 ‐ 20mm Ø VERTICAL RSB @ 600mm O.C., B.W.
10mm Ø VERT. BARS SPACED @  
(SEE C1 SCHEDULE) PROPERTY  0.80m O.C. W/ ALTERNATE  CLASS 'A' CONTINUOS 
LINE BENDS CONCRETE FOOTING
3 ‐ 10mm Ø  10mm Ø TRANSVERSE BARS  10mm Ø BARS @ 3 CHB 
LONGITUDINAL BARS SPACED @ 0.30m O.C., BEND AS  BOTHWAYS
Ø 10mm TRANSVERSE 

0.10 m
8 ‐ 20mm Ø VERTICAL RSB SHOWN
FFL TOILET, BATH RM. & LAUNDRY  FOOTING BARS @ 0.30m O.C.
0.90 m

(SEE C1 SCHEDULE) FLOOR  @ 2" BELOW FFL

0.30 m
0.10 m
BACK FILL BACK FILL 3‐ Ø12mm 
38mm THK  GRAVEL
BEDDING
CONTINOUS FOOTING 
BARS

0.10 m
CONCRETE  5"  CHB
COVERING BACK FILL
2.10 m

10mm Ø RSB COLUMN TIES  10mm Ø RSB COLUMN TIES 
SEE TIE  BEAM SCHEDULE 0.10 m 0.30 m 0.10 m
SPACED @ [email protected], 3@ SPACED @ [email protected], 3@
0.10m,  [email protected], REST @  0.10m,  [email protected], REST @ 
GRAVEL BEDDING
0.20m 0.20m WF2 DETAILS

3 WALL FRAME DETAILS
0.10 m0.40 m

18 ‐ 16mm Ø FOOTING  S2 1 : 25


REINFORCEMENT SPACED 
GRAVEL BED GRAVEL BEDDING @ 0.20m, O.C, B.W.

4.00 m

2 C1‐F2 DETAILS
S2 1 : 30
ARCHITECTURAL ENGINEERING PROJECT TITLE :  SHEET CONTENT  : PREPARED BY: APPROVED BY : SHEET NO.

2 ‐ Storey Residential Bldg. with C1‐F2 Details, Wall DRAFTED BY: BLAS G. ANQUILIANO III

Partial Roof Deck for Laundry
Area
Frame Details
3D VISUALIZATION: BLAS G. ANQUILIANO III
Jenzen Carl A. Agpalo S2
CHECKED BY: ENGR. C. S. LEJANO O W N E R / S
PTR NO. : DATE ISSUED: PTR NO. : DATE ISSUED:
PRC ID : VALID TIL: PRC ID : VALID TIL: LOC.: BINACAO ST., BRGY. ROXAS, SOLANO, N.V. DATE APPROVED: DATE APPROVED: SHEET 7 OF  17
L
(verify beam length)
X + BEAM WIDTH + L/4
L/4 L/4

8 ‐ 16mmØ RSB 4 ‐ 16mmØ  RSB 8 ‐ 16mmØ RSB

X = 0.20 m
A B C
L/5 L x 0.60 L/5
5.86 m
3.21 m 2.65 m 4 ‐ 16mmØ RSB 8 ‐ 16mmØ RSB 4 ‐ 16mmØ RSB
1.47 m USE 10mmØ STIRRUPS SPACED FROM SUPPORTS AS FOLLOWS :  1 @ 0.05m, 4 @ 0.10m, 6 @ 0.15m, REST @ 0.20m 

2 BEAM SECTION DETAIL
1 FLOOR BEAM FLOOR BEAM S3 1 : 30
STAIR WELL
2.35 m

2.16 m
1.15 m
S‐1 CANTILEVER 
FLOOR BEAM

FLOOR BEAM
FLOOR BEAM

SLAB
4.75 m

4.56 m
STIFFENER BEAM STIFFENER BEAM
10 mmØ RSB STIRRUP  10 mmØ RSB STIRRUP 
2.40 m

2.40 m
38mm CONC. COVER 38mm CONC. COVER
S‐1 S‐1
10 mmØ RSB STIRRUP 
2 FLOOR BEAM FLOOR BEAM
8 ‐ 16mmØ RSB  4 ‐ 16mmØ RSB 
3.38 m 2.67 m
2 ‐ 16mmØ RSB 

0.40 m

0.40 m
6.04 m

0.30 m
1 Level 2 FLOOR BEAM LAYOUT 4 ‐ 16mmØ RSB  8 ‐ 16mmØ RSB  2 ‐ 16mmØ RSB 
S3 1 : 100
0.30 m 0.30 m 0.20 m

SECTION AT SUPPORT SECTION AT MID‐SPAN
3 FLOOR BEAM SCHEDULES 4 STIFFENER BEAM SCHEDULES
S3 1 : 10 S3 1 : 10

ARCHITECTURAL ENGINEERING PROJECT TITLE :  SHEET CONTENT  : PREPARED BY: APPROVED BY : SHEET NO.

2 ‐ Storey Residential Bldg. with Level 2 Floor Beam DRAFTED BY: BLAS G. ANQUILIANO III

Partial Roof Deck for Laundry
Area
Lay‐out, Beam
Section Details, Floor
Beam Schedule,
3D VISUALIZATION: BLAS G. ANQUILIANO III
Jenzen Carl A. Agpalo S3
CHECKED BY: ENGR. C. S. LEJANO O W N E R / S
PTR NO. : DATE ISSUED: PTR NO. : DATE ISSUED: Stiffener Beam
PRC ID : VALID TIL: PRC ID : VALID TIL: LOC.: BINACAO ST., BRGY. ROXAS, SOLANO, N.V.
Schedule DATE APPROVED: DATE APPROVED: SHEET 8 OF  17
A B C A B C

5.86 m
3.21 m 2.65 m 5.86 m

0.98 m

1 FLOOR BEAM FLOOR BEAM
1 1m PARAPET WALL (FIREWALL)
RB
1m PARAPET WALL (FIREWALL)
RB 10mmØ RSB STIRRUPS 

1.15 m
RB

STIFFENER BM.

STIFFENER BM.

92°
STAIR WELL 38mm CONC. COVER
2.10 m

1.91 m

2.11 m
S1 S1 RB

RB
1.22 m
S1

88°

92°
2 ‐ 16mmØ RSB 

FLOOR BEAM
FLOOR BEAM
4.75 m

4.75 m
FLOOR BEAM

4.56 m
RB
1.03 m 2.20 m 2.02 m

0.35 m
2.65 m

2.65 m

2.45 m
SEE ROOF 1 DETAILS

4 ‐ 16mmØ RSB 
2 ROOF BEAM
GUTTER LN.
ROOF BEAM
2 BUILDING LN.

3.15 m 2.67 m
6.04 m 0.25 m
5.81 m

1 ROOF DECK BEAM LAYOUT (LEVEL 2 ROOF BEAM LAYOUT) 2 ROOF DECK ROOF BEAM LAYOUT 3 ROOF BEAM SCHEDULE


S4 1 : 100 S4 1 : 100 S4 1 : 10

LS
SS
SS / 4 SS / 2 SS / 4 LS / 4 LS / 2 LS / 4
10mmØ TEMPERATURE BARS TOP & 
BOTTOM SPACED @ 125mm ON CENTER T SLAB MARK THICKNESS OF SLAB and REINFORCEMENT DETAILS
LS/ 4

10mmØ TEMPERATURE BARS TOP &  R.C. BEAM R.C. BEAM SLAB THICKNESS (T) = 100mm +  MIDDLE STRIP


BOTTOM SPACED @ 125mm ON  SEE LS SPACING
FINISH SS = 12mmØ SPACED @ 
CENTER LS LONG SPAN DIRECTION 250mm
5
S4 1 : 40 S1 COLUMN STRIP: 100mmØ  BENT UP ALTERNATE @ L/4
LS/ 2
LS

SS RSB SS TEMPERATURE BARS SPACED @  FROM FACE OF SUPPORT


125mm ON CENTER, BOTHWAYS
SS / 4 SS / 2 SS / 4 LS = 12mmØ SPACED @ 
150mm
LS/ 4

BENT UP ALTERNATE @L/4
T

7 SLAB SCHEDULE FROM FACE OF SUPPORT
S4
LS RSB R.C. BEAM R.C. BEAM
SEE SS SPACING

4 TYPICAL PLAN OF 2‐WAY SLAB 6 SS SHORT SPAN DIRECTION
S4 1 : 50 S4 1 : 40

ARCHITECTURAL ENGINEERING PROJECT TITLE :  SHEET CONTENT  : PREPARED BY: APPROVED BY : SHEET NO.

2 ‐ Storey Residential Bldg. with Roof Deck Beam DRAFTED BY: BLAS G. ANQUILIANO III

Partial Roof Deck for Laundry
Area
Lay‐out, Slab Section
Details, Schedule of
Slab
3D VISUALIZATION: BLAS G. ANQUILIANO III
Jenzen Carl A. Agpalo S4
CHECKED BY: ENGR. C. S. LEJANO O W N E R / S
PTR NO. : DATE ISSUED: PTR NO. : DATE ISSUED:
PRC ID : VALID TIL: PRC ID : VALID TIL: LOC.: BINACAO ST., BRGY. ROXAS, SOLANO, N.V. DATE APPROVED: DATE APPROVED: SHEET 9 OF  17
1.10 m 2.15 m 0.90 m

0.99 m
4.66 m

0.90 m
1 2 3 4 5 6 7 8 9
UP
10

0.90 m
0.25 m
0.75 m
2" x 1" TUBULAR  11 1 2 3 4 5 6 7 8 9 10 11
HANDRAILS UP 12 13
12
LAUNDRY 
13
0.25 m DECK
14 (2nd  2" x 1" TUBULAR HANDRAILS
1 Level 1 ‐ STAIR PLAN flr.) 2 Level 2 ‐ STAIR PLAN
S5 1 : 50 S5 1 : 50

10mmØ SPACED @  300mm O.C. 2.80 m
12mmØ SPACED @  200mm O.C. STAIR WELL
3 ‐ 10mmØ STEP BARS SPACED @  150mm O.C.
STIFFENER BM.
12mmØ SPACED  0 . 25 m FLOOR BM. FLOOR BM.
@ 120mm O.C.
12mmØ SPACED @  FINISHED FLR.
200mm O.C. 13
16mmØ MAIN BAR  12
SPACED @ 200mm 11
0 . 22 m
16mmØ SPACED @ 150mm  10
STIFFENER BM. 9

FLOOR TO CEILING
BENT UP 1/2 @ L/4

2.07 m
VERIFY
8

2.80 m
10mmØ SPACED @ 

2.50 m
7

2.40 m
0.3m OC, BEND AS 3 ‐ 10mmØ 0.85 m
6
SHOWN 5
3 STAIR SECTION DETAIL 1 2.37 m 4
S5 1 : 25 STAIR WELL
3
2
0.20 m 1 FINISHED FLR.
14
16mmØ SPACED @ 
13
STIFFENER 
150mm BENT UP 1/2 @  BM.
12
L/4
12mmØ SPACED @  200mm O.C. FLOOR BM.
11
10mmØ SPACED @  300mm O.C. 10
FLOOR TO CEILING

3.10 m
3 ‐ 10mmØ STEP BARS SPACED @   8
2.70 m

2.70 m
SEE STIFFENER  150mm O.C. 7
BEAM SCHEDULE 6
12mmØ SPACED @ 200mm O.C. 5
STORAGE BELOW 4
16mmØ MAIN BAR SPACED @ 200mm 3
2
12mmØ SPACED @ 120mm O.C. 1 FINISHED FLOOR

4 STAIR SECTION DETAIL 2 5 STAIR ELEVATION 6 3D VIEWS STAIRS


S5 1 : 25 S5 1 : 60 S5 1 : 100

ARCHITECTURAL ENGINEERING PROJECT TITLE :  SHEET CONTENT  : PREPARED BY: APPROVED BY : SHEET NO.

2 ‐ Storey Residential Bldg. with Stair Plans, Stair DRAFTED BY: BLAS G. ANQUILIANO III

Partial Roof Deck for Laundry
Area
Section Details, 3D
Views Stairs
3D VISUALIZATION: BLAS G. ANQUILIANO III
Jenzen Carl A. Agpalo S5
CHECKED BY: ENGR. C. S. LEJANO O W N E R / S
PTR NO. : DATE ISSUED: PTR NO. : DATE ISSUED:
PRC ID : VALID TIL: PRC ID : VALID TIL: LOC.: BINACAO ST., BRGY. ROXAS, SOLANO, N.V. DATE APPROVED: DATE APPROVED: SHEET 10 OF  17
A B C A B C

5.86 m
3.21 m 2.65 m
3.21 m 2.65 m

1 P.L.
1 PL

SEE ROOF DECK ROOF FRAMING 

G.A. PRE‐PAINTED FLASHINGS
2" X 3" C‐PURLINS  SEE ROOF DECK ROOF PLAN
PLAN
SPACED @ 0.60m
4.75 m

4.75 m
ROOF BEAM
2.10 m

2" THK FASCIA

2.50 m
PROVIDE 0.20m OFFSET TO 
PROPERTY LINE G.A. PRE‐PAINTED ROOF SHEETS
ROOF BEAM DURARIB SERIES
2 2
0.20 m
P.L. PL
G.A. PRE‐PAINTED GUTTER W/ 
3"Ø PVC DOWN‐SPOUTS
2" THK FASCIA
1.44 m 1.44 m 1.44 m 1.44 m 5.74 m

2" X 6" TUBULAR RAFTERS SPACED AS SHOWN
5.75 m

1 ROOF FRAMING PLAN (level 2) 2 ROOF PLAN (level 2)
S6 1 : 100 S6 1 : 100

ARCHITECTURAL ENGINEERING PROJECT TITLE :  SHEET CONTENT  : PREPARED BY: APPROVED BY : SHEET NO.

2 ‐ Storey Residential Bldg. with Roof Framing Plan DRAFTED BY: BLAS G. ANQUILIANO III

Partial Roof Deck for Laundry
Area
(Level 2) , Roof Plan
(Level 2)
3D VISUALIZATION: BLAS G. ANQUILIANO III
Jenzen Carl A. Agpalo S6
CHECKED BY: ENGR. C. S. LEJANO O W N E R / S
PTR NO. : DATE ISSUED: PTR NO. : DATE ISSUED:
PRC ID : VALID TIL: PRC ID : VALID TIL: LOC.: BINACAO ST., BRGY. ROXAS, SOLANO, N.V. DATE APPROVED: DATE APPROVED: SHEET 11 OF  17
A B C A B C
4.97 m

1.35 m 1.35 m 1.35 m


2" x 6" TUBULAR RAFTERS SPACED  3.21 m 2.65 m
AS SHOWN
2" x 3" C‐PURLINS  2.20 m 2.77 m
SPACED @ 0.60m

1 1
1.28 m

G.A. PRE‐PAINTED 

1.82 m
G.A. PRE‐PAINTED 
FLASHINGS

2.41 m

2.41 m
ROOF BEAM
FLASHINGS G.A. PRE‐PAINTED 
2" THK FASCIA G.A. PRE‐PAINTED GUTTER W/ 2"Ø  ROOF SHEETS
1.20 m

PVC DOWN‐SPOUTS DURARIB SERIES G.A. PRE‐PAINTED GUTTER 


2" THK FASCIA W/ 2"Ø PVC DOWN‐SPOUTS
2.18 m 2.79 m
SEE LEVEL 2 ROOF PLAN
SEE ROOF FRAMING PLAN
2 P.L.
2 P.L.

1 ROOF FRAMING PLAN (roof deck) 2 ROOF PLAN (roof deck)
S7 1 : 100 S7 1 : 100

ARCHITECTURAL ENGINEERING PROJECT TITLE :  SHEET CONTENT  : PREPARED BY: APPROVED BY : SHEET NO.

2 ‐ Storey Residential Bldg. with Roof Framing Plan DRAFTED BY: BLAS G. ANQUILIANO III

Partial Roof Deck for Laundry
Area
(Roof Deck), Roof
Plan (Roof Deck)
3D VISUALIZATION: BLAS G. ANQUILIANO III
Jenzen Carl A. Agpalo S7
CHECKED BY: ENGR. C. S. LEJANO O W N E R / S
PTR NO. : DATE ISSUED: PTR NO. : DATE ISSUED:
PRC ID : VALID TIL: PRC ID : VALID TIL: LOC.: BINACAO ST., BRGY. ROXAS, SOLANO, N.V. DATE APPROVED: DATE APPROVED: SHEET 12 OF  17
10mmØ VERTICAL RSB SPACED @ 0.50m

0.35 m
0.30 m 0.05 m 0.40 m 0.40 m 0.40 m
6" THK CHB, REINFORCED PARAPET WALL
0.20 m
G.A. PRE‐PAINTED FLASHING

0.05 m
2" X 2" ANGLE BAR PURLIN CONNECTOR VOS
2" x 3" C‐PURLIN

0.05 m
0.16 m

ANGLE BAR 

0.28 m

0.40 m

0.40 m
0.40 m
0.35 m
FRAME
2" x 2" x 3" LONG, 3mm THK  ANGLE BAR CONNECTOR
0.19 m

4 ‐ 16mmØ  HEAVY DUTY EXPANSION BOLTS

0.07 m
15mm THK MS PLATE
ROOF  1" CONTINOUS FLAT BAR G.A. PRE‐PAINTED 
BEAM 3"Ø PVC  0.15 m 1 1/2" FLAT BARS SPACED @ 0.40m FLASHING SHEETS
DRIP 
DOWNSPOUT
EDGE 1 1/2" x 1 1/2" x 6mm 
1 RAFTER CONNECTION DETAIL @ STEEL‐CONC. CONNECTION THK ANGLE MAIN BAR 
S8 1 : 20
GUTTER PROFILE FLASHING PROFILE  FRAME
(VOS ‐ VERIFY ON SITE)
(non gutter side of 
4 FASCIA & GUTTER PROFILE DETAILS roof)
S8 1 : 20
1" x 1" x 8" LONG ANGLE BAR AS 
RAFTER TO GIRDER CONNECTOR
0.15 m
2" x (h") THK TUBULAR GIRDER (h" may vary)

2 ‐ 12mmØ DOWELS BEND AS SHOWN,  15mm THK MS PLATE


ROOF BEAM ROOF BEAM FULLY WELD TO RAFTERS
16mmØ  HEAVY DUTY 
EXPANSION BOLTS

0.21 m
2 ‐ 2" x 2" x 2" 
LONG ANGLE BAR
2" x 6" C‐PURLIN RAFTER
R.C. COLUMN

2 RAFTER CONNECTION DETAIL @ MID SUPPORT 5 MS PLATE ‐  TUBULAR CONNECTION DETAIL
S8 1 : 20 S8 1 : 10
G.A. PRE‐PAINTED LONG 
SPAN DURARIB SERIES
10mmØ SAG ROD BARS
2" x 3" 2mm" THICK C‐PURLINS
2" x 2"  X 3mm THK ANGLE 
BAR AS PURLIN CONNECTOR

G.A. PRE‐PAINTED 
2" x 3" 2mm" THICK C‐PURLINS GUTTER
G.A. PRE‐PAINTED FLASHING ON 
2" x 6" TUBULAR RAFTERS ROOF 
ANGLE BAR FRAME, PROVIDE DRIP 
BEAM
2 ‐ 12mmØ DOWELS BEND AS  EDGE BELOW GUTTER
R.C. 
SHOWN, FULLY WELD TO RAFTERS COLUMN Ø3" PVC DOWNSPOUTS
Ø3" ‐ 90° ELBOW PVC PIPE
SUPPORT BRACKETS
3 RAFTER CONNECTION DETAIL @ OVERHANG 6 AERIAL PERSPECTIVES
S8 1 : 25 S8 NTS

ARCHITECTURAL ENGINEERING PROJECT TITLE :  SHEET CONTENT  : PREPARED BY: APPROVED BY : SHEET NO.

2 ‐ Storey Residential Bldg. with Rafter Connection DRAFTED BY: BLAS G. ANQUILIANO III

Partial Roof Deck for Laundry
Area
Details, Gutter &
Fascia Profiles
3D VISUALIZATION: BLAS G. ANQUILIANO III
Jenzen Carl A. Agpalo S8
CHECKED BY: ENGR. C. S. LEJANO O W N E R / S
PTR NO. : DATE ISSUED: PTR NO. : DATE ISSUED:
PRC ID : VALID TIL: PRC ID : VALID TIL: LOC.: BINACAO ST., BRGY. ROXAS, SOLANO, N.V. DATE APPROVED: DATE APPROVED: SHEET 13 OF  17