RF Exposure Evaluation Report: Shenzhen Huaxia Testing Technology Co., LTD
RF Exposure Evaluation Report: Shenzhen Huaxia Testing Technology Co., LTD
RF Exposure Evaluation Report: Shenzhen Huaxia Testing Technology Co., LTD
, Ltd
1F., Block A of Tongsheng Technology Building, Huahui Road, Dalang Street, Longhua District,
Shenzhen, China
Telephone: +86-755-26648640
Fax: +86-755-26648637 Report Template Version: V04
Website: www.cqa-cert.com Report Template Revision Date: 2018-07-06
Tested By:
(Lewis Zhou)
Reviewed By:
(Jun Li)
Approved By:
(Sheek Luo)
The test report is effective only with both signature and specialized stamp, The result(s) shown in this report refer only to the sample(s)
tested. Without written approval of CQA, this report can’t be reproduced except in full.
Shenzhen Huaxia Testing Technology Co., Ltd
Report No.: CQASZ20210600783E-02
1 Version
Revision History Of Report
Page:2 of 6
Shenzhen Huaxia Testing Technology Co., Ltd
Report No.: CQASZ20210600783E-02
2 Contents
Page
1 VERSION............................................................................................................................................................................. 2
2 CONTENTS......................................................................................................................................................................... 3
3 GENERAL INFORMATION.............................................................................................................................................. 4
3.1 CLIENT INFORMATION.................................................................................................................................................... 4
3.2 GENERAL DESCRIPTION OF EUT....................................................................................................................................4
4 RF EXPOSURE EVALUATION....................................................................................................................................... 5
4.1 RF EXPOSURE COMPLIANCE REQUIREMENT..................................................................................................................5
4.1.1 Standard Requirement...................................................................................................................................... 5
4.1.2 Limits.................................................................................................................................................................... 5
4.2 EUT RF EXPOSURE EVALUATION..................................................................................................................................6
Page:3 of 6
Shenzhen Huaxia Testing Technology Co., Ltd
Report No.: CQASZ20210600783E-02
3 General Information
3.1 Client Information
Applicant: SHENZHEN HUBSAN TECHNOLOGY CO., LTD
Address of Applicant: Unit 2801-2802A, Building F, Xinghe WORLD , Yabao Road,
Bantian Street, Longgang District, Shenzhen,China.
Manufacturer: SHENZHEN HUBSAN TECHNOLOGY CO., LTD
Address of Manufacturer: Unit 2801-2802A, Building F, Xinghe WORLD , Yabao Road,
Bantian Street, Longgang District, Shenzhen,China.
Factory: Dongguan Tengsheng Industrial Co., Ltd.
Address of Factory: A22# Luyi Street, Tianxin Village, Tangxia Town, Dongguan, China.
Page:4 of 6
Shenzhen Huaxia Testing Technology Co., Ltd
Report No.: CQASZ20210600783E-02
4 RF Exposure Evaluation
4.1 RF Exposure Compliance Requirement
4.1.1 Standard Requirement
According to KDB447498D01 General RF Exposure Guidance v06
4.3.1. Standalone SAR test exclusion considerations
Unless specifically required by the published RF exposure KDB procedures, standalone 1-g
head or body and 10-g extremity SAR evaluation for general population exposure conditions, by
measurement or numerical simulation, is not required when the corresponding SAR Exclusion
Threshold condition, listed below, is satisfied.
4.1.2 Limits
The 1-g and 10-g SAR test exclusion thresholds for 100 MHz to 6 GHz at test separation distances
≤ 50 mm are determined by:
[(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance, mm)] ·
[√f(GHz)] ≤ 3.0 for 1-g SAR and ≤ 7.5 for 10-g extremity SAR, where
Page:5 of 6
Shenzhen Huaxia Testing Technology Co., Ltd
Report No.: CQASZ20210600783E-02
1) For 2.4G
eirp = pt x gt = (E x d)2/30
where:
pt = transmitter output power in watts,
gt = numeric gain of the transmitting antenna (unitless),
E = electric field strength in V/m, ---10((dBμV/m)/20)/106 ,
d = measurement distance in meters (m)---3m,
So pt = (E x d)2/30 / gt
Page:6 of 6