IRIS - NV Control Panel: Regenerative Resistance ERO Panel Brake Resistance Trans

Download as pdf or txt
Download as pdf or txt
You are on page 1of 20
At a glance
Powered by AI
The document provides detailed information about the components, wiring, and functions of an IRIS_NV elevator control panel.

Some of the main components mentioned include the P.G card, main board, terminal block, SMPS, IPM module, noise filter housing.

Several terminal blocks like GOV, CIN, HE, CE, MB, HS, HD, INT, EST, Mic Name are described along with their pin numbers and functions.

IRIS_NV Control Panel

Regenerative Resistance
ERO Panel

Brake Resistance

Trans

CTT

IPM
Main Board
SMPS
Monitor board
P.G Card

Terminal Block
Noise Filter

Field Panel SW

OCB & FSK1


IRIS_NV Control Panel

 ERO Panel

E.STOP DZI NOR/INS Up Com Down

 RZ1

( Brake Resistance )
IRIS_NV Control Panel

 Trans

FU1
AC 110V
AC 380V
FU2
AC 123V

AC 220V
FU3
IRIS_NV Control Panel

 Circuit Breaker & CTT  SW CTT  FSK1 & OCB

CP1 Circuit Breaker for input voltage of SMPS SW For Drive voltage of Motor
FU1 AC 110V Fuse [2A]  Safety Chain OCB Main Breaker in control panel
FU2 AC 123V Fuse [4A]  Brake FSK1 Car Light Switch
FU3 AC 220V Fuse [2A]  Car Door FSK2 Hoistway Light Switch
KAD Safety Chain (Car Door & Landing Door) FSK3 Hoistway Light Switch
BY Brake CTT
KMZ Starting CTT (10T, C1ST…)
IRIS_NV Control Panel

 SMPS

 Power source of Main Board


AC 220V DC 24V
SMPS

 Hall Power Source


IRIS_NV Control Panel

◆ P.G Card

( ABZ Incremental 5V PG card )


Matched with UVW encoder
Pin Terminal Label Function

JP2.1 A+ Encoder A phase signal +

JP2.2 A- Encoder A phase signal -

JP2.3 B+ Encoder B phase signal +

JP2.4 B- Encoder B phase signal -

JP2.5 Z+ Encoder Z phase signal +

JP2.6 Z- Encoder Z phase signal -

JP2.7 V+ Encoder power positive pole

JP2.8 V- Encoder power negative pole

JP2.9 PE Shield earth

JP2

A+ A- B+ B- Z+ Z- V+ V- PE
IRIS_NV Control Panel

◆ P.G Card

( AS T024) )
Matched with SINCOS encoder
Terminal Label Function

A+, A- Encoder A phase signal

B+, B- Encoder B phase signal

R+, R- Encoder Z phase signal +

C+, C- Encoder SIN signal

D+, D- Encoder COS signal

V+ +5V

0V GND
IRIS_NV Control Panel

◆ Main Board
Relay Output CAN
JP4 JP5 Communication
JP1
JP2 JP3

HV OC input JP6
Isolated power
input
JP7

Expansion
board interface

Analog signal
LV OC input input

JP8 JP9 JP10 JP11


IRIS_NV Control Panel

MIC ID No. Name Description Assembly

JP1.1 XCOM X20-X22 input signal common port 0V


JP1.2 X20 Positive voltage position in safety loop, 110V/220V input Input
JP1 JP1.3 X21 Positive voltage position in door lock loop, 110V/220V input Input
JP1.4 X22 Positive voltage position in hall door lock, 110V/220V input Input
JP1.5 XCOM X20-X22 input signal common port 0V, connect with JP1.1 internally
JP2.1 Y0 Brake contactor output Output
JP2.2 Y1 Brake excitation contactor output Output
JP2
JP2.3 Y2 Main contactor output Output
JP2.4 COM1 Common port of output relay Y0-Y3
JP3.1 Y3 Pre-opening relay Output
JP3.2 Y4 ALP signal output Output
JP3.3 COM2 Common port of output relayY3-Y4
JP3 JP3.4 Y5 Firefighting signal output Output
JP3.5 COM3 Common port of output relayY5 Output
JP3.6 Y6 Reserved for spare
JP3.7 COM4 Common port of output relayY6
JP4.1 0V 0V DC
JP4 JP4.2 CAN0H Call serial communication signal end (TXA0+)
JP4.3 CAN0L Call serial communication signal end (TXA0-)
IRIS_NV Control Panel

MIC ID No. Name Description Assembly

JP5.1 0V 0V DC

JP5 JP5.2 CAN1H Parallel connection serial communication signal end (TXA1+)

JP5.3 CAN1L Parallel connection serial communication signal end (TXA1-)

JP6.1 0V Isolated OV DC

JP6 JP6.2 CAN2H Community monitor (TXA2+)

JP6.3 CAN2L Community monitor (TXA2-)

JP7.1 G5VIO Isolated power 0V

JP7.2 +5VIO Isolated power +5V

JP7 JP7.3 NC, undefined

JP7.4 G24VIO OC output isolated power 0V

JP7.5 +24VIO OC input isolated power+24V

Inspection signals 1, disconnection indicates Inspection, X0 and X1 all


JP8.1 X0 Input
connection indicate automatic

Inspection signals 2, disconnection indicates Inspection, X0 and X1 all


JP8.2 X1 Input
connection indicate automatic
JP8
JP8.3 X2 Up signal, Inspection: inching upward; attendant : Upward diversion Input

Down signal, Inspection: inching downward; attendant: downward


JP8.4 X3 Input
diversion
IRIS_NV Control Panel

MIC ID No. Name Description Assembly

JP8.5 X4 First upward slow down switch Input

JP8.6 X5 First downward slow down switch Input

JP8.7 X6 Up-leveling switch Input


JP8
JP8.8 X7 Down-leveling switch Input

JP8.9 X8 Motor power contactor detection Input

JP8.10 X9 Brake contactor detection Input

JP9.1 X10 Left band-type brake switch detection Input

JP9.2 X11 Right band-type brake switch detection Input

JP9.3 X12 Motor temperature examination signal Input

JP9.4 X13 Advanced door opening relay detection Input

JP9.5 X14 Door signal detection Input


JP9
JP9.6 X15 fireman return/ fireman's switch (parameter selection) Input
Emergency leveling input for power cut/earthquake/backup power
JP9.7 X16 Input
(parameter selection)
JP9.8 X17 Door lock loop relay detection Input

JP9.9 X18 Second upward slow down switch Input

JP9.10 X19 Second downward slow down switch Input


IRIS_NV Control Panel

MIC ID No. Name Description Assembly

JP10.1 +24VIO Input isolated power+24V, connect with P7.5 internally

Connect with JP10.1 externally, it is valid if input is low power, JP10.3


JP10 JP10.2 VSIO is input common port; When connect with JP10.3 externally, it is valid
if input is high power, JP10.1is input common port

JP10.3 G24VIO Input isolated power 0V, connect with JP7.4 internally

JP11.1 0V Analog signal output 0V

JP11 JP11.2 AIN - Difference analog signal input-

JP11.3 AIN + Difference analog signal input+

ON Monitor CAN terminal resistance valid state


SW2 Factory setup is OFF for SW2
OFF Monitor CAN terminal resistance null state

ON Program burning state Factory setup is OFF


SW3
OFF Normal working state (Maintain OFF during operation)
IRIS_NV Control Panel

◆ Monitor Board

Display Meaning Remark

Community communication flash-communication is connected


Monitor
Supervisory panel

CPU working condition Rapid flashing -normal


medium speed –in self study
State
slow -elevator fault
no flash -contact manufacturer

CAN Cabin/shaft communication Flash-communication connected

Duplex/group control
Group Flash-communication is connected
communication

IN/SOR Inspection/automatic mode Light on-auto/light off-inspection

Encode Rotary encoder Light on-speed feedback

Safety Safety circuit Light on-safety circuit is connected

DL Door lock Light on-door lock is connected

HDL Hall door lock Light on-hall door lock is connected


IRIS_NV Control Panel

 IPM

 Terminal Block  Noise Filter


IRIS_NV Control Panel

 Housing Function

GOV Information Description CIN Information Description Descriptio


HE Information
n
GOV-01 CA:03-OS CN10-01 JP8.1-JP8.1
Safety line HE-01 12V
GOV-02 OS-CA:02 CN10-02 JP8.2-JP8.2 Interphone
Duplex HE-02 (Supervisory GND
GOV-03 No use CN10-03 JP8.3-JP8.3
Room)
HE-03 T
GOV-04 No use CN10-04 JP8.4-JP8.4
HE-04 No use
GOV-05 No use CN10-05 No use
HE-05 No use
GOV-06 No use CN10-06 No use
HE-06 No use

CE Information Description MB Information Description HS Information Description


CE-01 AIR1-1 Brake HS-01 No use
Aircon. MB-01 Brake(+)
power
CE-02 AIR HS-02 No use
MB-02 Brake(-)
CE-03 No use HS-03 No use
MB-03 Motor Thermal
CE-04 No use HS-04 No use
MB-04 Brake s/w BS1
CE-05 No use HS-05 No use
MB-05 BS2
CE-06 No use HS-06 No use
MB-06 COM
IRIS_NV Control Panel

 Housing Function

HD Information Description INT Information Description Mic Name Information Description


HD-01 TXV+ INT-01 12V HB-01 No use
Hall Interphone
HD-02 TXV- INT-02 GND HB-02 No use
Communicati (Controller)
HD-03 on TXA+ INT-03 T HB-03 No use
HD-04 TXA- INT-04 No use HB-04 No use
HD-05 No use INT-05 No use HB-05 Safety line ERO-2BFS
HD-06 No use INT-06 No use HB-06 No use
HB-07 No use
HB-08 Final limit-Fire1
Safety line
HB-09 Fire1-2PES
Mic Name Information Description EST Information Description
HB-10 No use
HC-01 Landing door EST-01 No use
Safety line HB-11 No use
HC-02 Landing door EST-02 No use
HB-12 No use
HC-03 No use EST-03 No use
HC-04 No use EST-04 No use
HC-05 No use EST-05 No use
HC-06 No use EST-06 No use
IRIS_NV Control Panel

 Housing Function

Mic Name Information Description Mic Name Information Description Mic Name Information Description
HA-01 UL CC-01 No use CB-01 No use
HA-02 DL CC-02 No use CB-02 No use
HA-03 2LS CC-03 No use CB-03 No use
HA-04 Main Board 1LS CC-04 EFS1 1st Firman S/W CB-04
HA-05 Input EFK CC-05 12V CB-05 Inspection Run
Interphone
HA-06 Com. CC-06 GND CB-06 TCI-ERO
HA-07 4LS CC-07 No use CB-07 1LV
HA-08 3LS CC-08 Interphone T CB-08 2LV
HA-09 Final limit-GOV CC-09 PE 2SQ CB-09 1LV/2LV COM
HA-10 Final limit-1PES CC-10 No use CB-10 1LV/2LV 24VDC
Safety line
HA-11 Pit safety line CC-11 No use CB-11 No use
HA-12 Pit safety line CC-12 Interphone Warning Light CB-12 No use
IRIS_NV Control Panel

 Housing Function

Mic Name Information Description Mic Name Information Description


CA-01 TCI-ERO MSK-01 Safety Start
CA-02 TB2:102-ESB MSK-02 Before GOV
CA-03 Safety line SOS-OS MSK-03 After GOV
CA-04 MES-GS MSK-04 Safety line Safety End
CA-05 TB2:116-GS MSK-05 Safety End(Car Door)
CA-06 CAR TB2:501 MSK-06 Safety End(Landing Door)
CA-07 LIGHT/EMPU TB2:502 MSK-07 Safety End(Com)
CA-08 ESB JUMP MSK-08 Before TCI
Safety line
CA-09 EEC JUMP MSK-09 Inspection line Start(UP)
CA-10 TB2:200-SMPS(CAR TOP) MSK-10 Start(DOWN)
CAR SMPS
CA-11 TB2:202-SMPS(CAR TOP) MSK-11 No use
CA-12 220VAC FAN-FIRE1 MSK-12 No use
MSK-13 No use

No use

MSK-19 No use
MSK-20 No use
MSK-21 No use
IRIS_NV Control Panel

 Field panel
IRIS_NV Control Panel

InTae, Park
Overseas Support Team
[email protected]
[email protected]