Working Drawings Sample
Working Drawings Sample
North
• retaining walls higher than 1m in height to be engineered designed
East • retaining walls constructed from treated pine timber or rock as per plans
• agriculture drainage systems to be used
• retaining walls may change location at supervisor's discrection if required
• fencing in accordance with developer covenants
• landscaping in accordance with developer covenants
• driveway gradient not to exceed 1:5
• Batters to comply appropriate soil classification described in table 3.1.1.1.BCA Vol.2.
• stormwater to legal point of dishcharge
Legend
denotes batter
CO
rock retaining wall
MMUN
ELECT
timber retaining wall
tiered rock retaining wall
max height 1m 1 0 .1 6
Lot 2405 direction of fall
IC A T IO
R IC IT Y P IT
FGL 17.500 Proposed FGL RL
10 .0 9
1 0 .0
9 .5 0
11 .7 5
8 .5 0
12 .2 5
7 .5 0
11 .2 5
7 .5 3
10 .0 8
9 .0 0
8.00 7.75
10 .7 5
NS
P IL L A R
BANK
10 .0 5
0
TOP OF
1.8m high fence return
10.07
9.75
10.2
9.25
NGL RL
8.25
S
8.75
16.65
1m back from front building line
10 .00
5
11.0
RO
10.5
12 .0 0
11 .5 0
12 .5 0
OFW
7 .3
IT
0
5
9.7 5
point of discharge
7 .2 5
CP
ATE
RW Roof Water Line
Lot 2409
LIG
R IL
12.53 9.50
1,500
Stormwater Line
9.3 3
9.35
H
6 .8
30.127
9.42
347°09'55"
TP
7 .0 8
5
S Sewer Line
OLE
EPI S
6 .9 2
L
OP
7.05
6.96
OP
6 .9
7 .0
2,550
RW
0
RW 1800mm high
RW 7 .0 0
9.23
9
coloured concrete driveway finish timber fence
12.41 m/box
ELP
9.50
7.25
7.50
7.75
1,500
8.00
8.25
8.50
8.75
9.00
9 .2 5
590X350 rendered
9
HWS
dp HTB
31
brick piers
dp fill dismantle existing footpath painted horizontal
9.37 cut
14.0
11.6 7
6.89
S
replace with coloured concrete timber battens
6 .8
R L 6 .8 1 K E R B
6
FFL RL 10.570 0
N A IL INE N C H M A R K
S IT E B
1500mm high timber top
tiered rock retaining wall
6.75
78
PAD (FGL) 9.600 approx. FFL RL 7.810 rail & posts with pool
max height 1m style infill fencing
9.25 PAD RL 7.500
(A r b it r
10,440
11 6 .6
2
G
L
.7 7 Single timber gate
CO
257°09'55"
6 .6
NC
ary)
3,850 fill L Rendered Leterbox
2
cut
6 .7
9.32
9
5
6.88 S
Lot 2408
Pla gor
103
17
°0 9
11.74
3,5
'3 5
374 M2 59
9 .2 5
6 .5
6
10.7 5
"
11.63 11
Lot Number: 2406
ce
Gre
11 .5 0 .0 0
59
6.5 0
11 .2 5 10 dp Registered Plan Number: SP 230012
15.
.2 5 1
6 .3
0 .5
gate
S
2,060
9.10
57
dp Parish: Stapylton
9 .1 1
RW RW RW
10 0
9.26
6
.0 0
7 .0 0
9 .2 County: Stanley
Mc
10.1
6 .3
2
6 .4
OP 6 .5
2
Local Authority: Ipswitch C.C
0
9
WM
9 .7 23.3 167°09'55" OP
1,770
6 .6 5
9 .5 5
FH
6 .2
6
0
9 7 .2
Site Area: 374M2
9 .0 .2 5 8 .0 0
stormwater to legal
8 .7 8 .5
7.20
WM
8 .2 7 .7 5 5
rock retaining wall S
7.74
0 5 0 5 7 .5 0
9.05
6 .1
6
Site Coverage: 40%
max height 1m point of discharge
S L 6 .3 6 M E T E R
WATE
F IR E H
rock retaining wall 1.8m high fence & gate return Driveway Gradient
R
max height 1m 1m back from front building line Grade 1:8
YDRAN
Grade 1:8 1:4 1:8
Transitional
4,300 16,045 2,955 Distance n/a n/a n/a
NGL (boundary) R.L 6.800
T
FFL R.L 7.810
Height Gain 1.01 m
Distance 8.3 m
Lot 2407
Area Calculations
Living Lower: 29.56 sqm
Living Upper: 119.98 sqm
Garage: 36.08 sqm
Porch: 3.98 sqm
Alfresco: 12.31 sqm
Total: 201.91 sqm
South
• Provide gpo & cold water tap provisions to d/w space
North
• Continuous flow hws, position to be confirmed
• Mechanically vent rooms without natural ventilation
East
• All shower roses to be AAA rated
• Water pressure limited to 500KPa at the meter
• All ground drains to be > 1000mm from gas bottle location
• Nogging to be positioned where indicated in bathroom at
1100 afl for fixing of towel rail (TR) 8,010
• Handrail to be fixed to one side of all stairways (1000mm or higher only)
• Water connection to fridge space at 1900mm afl 6,060 1,950
• Opening windows in bedrooms with fall height of 2m or greater to be restricted 230 5,600 230 1,600 350
to max. 125mm opening (Sliding windows with keyed vent locks;
awning with ratchet restriction) 230 4,600 230 1,000
1,000
1,000
line of building above
col. conc. tap
dp
m/box
230
230
820
HWS
5,610
6,070
5,610
plain conc.
7,010
porch ceiling framed
Stair Specification
Rise 2760
to soffit height
Riser 184 (15) 160
70 230 brickwork above
Going 250
plumbing duct steel lintel
10,440
10,440
2RG 618
70
350
230
160
90
90
90
2 1 820 CSD
90
1,080
820
230
1,010
1,000
1,000
1,300
1,300
Porch
220
UP
col. conc.
3
70
4
70
70
70
3,290
820
1,500 VSD
70 1,590
230
820
6
350
Linen
70 930
930
7
1815 XO/OO SW
8 door height to suit
shlvs
store
70
3,370
Bed 4
3,130
2,910
under 720
1,800 VSD
70
3,020
carpet
L'dry
1,910
1,910
1,470
Robe
trh
920
W/M/S
820
0906 XO SW
230
230
230
230
230
230
OBS dp
exp. agg. dp
Note:
South
• Lift off hinges to wc door
North
• Provide gpo & cold water tap provisions to d/w space
• Continuous flow hws, position to be confirmed
East
• Mechanically vent rooms without natural ventilation
• All shower roses to be AAA rated 16,385
• Water pressure limited to 500KPa at the meter
• All ground drains to be > 1000mm from gas bottle location 450 15,485 450
• Nogging to be positioned where indicated in bathroom at 530 70
70 2,150 70 1,500 70 4,100 70 3,000 70 930 70 2,715 70
1100 afl for fixing of towel rail (TR)
• Handrail to be fixed to one side of all stairways (1000mm or higher only) 70 4,220 70 2,700 900 70 3,000 70 4,315 70
• Water connection to fridge space at 1900mm afl 70 530
• Opening windows in bedrooms with fall height of 2m or greater to be restricted 70 4,785 70 1,100 70 4,430 70
to max. 125mm opening (Sliding windows with keyed vent locks;
awning with ratchet restriction) A
spreader
dp dp dp
OBS
70
1215 XO SW 0906 XO SW
water tap @
ohc
450
450
600
70
70
70
70
900 shlvs P'TRY w/o 1900mm afl 900
F/S 900
0906 XO SW
0615 XO SW
1,800 VSD
Robe
OBS
W.I.R m/o prov. trh
1,900 Ens. tr
2,090
1,300
above
Kitchen WC Bath
Bed 2
3,220
3,220
720
720
m/h d/w prov.
720
720
trh
1.1m X 0.5m
shlvs
under carpet
a/c ext.
tr
900
70
800
a/c int.
70
200mm o/hang to benchtop
820
590
70
70
plumbing duct under
0615 XO SW
1215 XO SW
1,000
1,000
Bed 1
160
590
Dining
3,800
3,500
carpet tiles Family
9,680
9,680
70
8,780
8,780
2 tiles 160 600
1
70
70
1,200 VSD
1,300
Linen
1000mm high wall
1,390
3
820
5,940
4
5
3,080
shlvs
70
70
1218 XO SW
820
70
6
7
dp
4,280
Living 8
spreader
1215 XO SW
9
2121 SGD
2,700 VSD
tiles
Alfresco 10
Bed 3
Robe
2,910
2,870
timber decking 11
12
carpet
down
a/c int. 14 13
dp
70
a/c ext.
3
2
450
450
plain conc. slab dp
1 1.1m X 0.5m Stair Specification
UP
900mm
down A Rise 2760
Riser 184 (15)
Going 250
2RG 618 Elevations
70 4,220 70 2,700 900 70
70 530 4
70 4,785 70 1,100 70 3,200 70
4,290 9,965 1,230
2 1
450 15,485 450 3
16,385
Area Calculations
Living Lower: 29.56 sqm
Living Upper: 119.98 sqm
Garage: 36.08 sqm
Porch: 3.98 sqm
Alfresco: 12.31 sqm
Total: 201.91 sqm
Bounday
Bounday
UTP 5,200
UJL 4,860
7,637
hardies 133mm wide axon
UFFL 2,760
TP 2,440
JL 2,100
3,000
3,000
meter box
wall hung clothes line
rendered brickwork
FFL 0
Elevation 1
UTP 5,200
UJL 4,860
steps
UFFL 2,760
a/c
Area Calculations
Note: Living Lower: 29.56 sqm
• Refer to colour specifications for detailed internal and external colours / materials Living Upper: 119.98 sqm
Elevation 2 • Articulation joints as per engineering details Garage: 36.08 sqm
Porch: 3.98 sqm
• All opening windows with fall height of 2m or greater to be restricted to max. 125mm opening
Alfresco: 12.31 sqm
(Sliding windows with keyed vent locks; awning with ratchet restriction)
Total: 201.91 sqm
Bounday
Bounday
powder coated aluminium framed
windows and sliding glass doors 450
450
colorbond sheet roof @ 25°pitch
450 colorbond fascia & gutter
UFFL 2,760
TP 2,440
a/c JL 2,100
HWS (gas)
3,000
rendered brick section
steps NGL core filled with 1/M12 rod typical
1000mm high balustrading
to build. spec.
FFL 0
shs columns to eng. spec.
NGL
wall hung clothes line
Elevation 3
450 450
Bounday
UTP 5,200
Bounday
UJL 4,860
a/c unit
UFFL 2,760
TP 2,440 NGL
tiered rock retaining wall
JL 2,100 max. height 1m
3,000
3,000
FGL
350sq. rendered brick pier NGL
FGL
core filled with 1/M12 rod typical
m/box
shs columns to eng. spec.
FFL 0
UFFL 2,760
5,200
320
TP 2,440
JL 2,100 DETAIL 1
10mm plasterboard fixed to
underside of joist
cornices as per builder's
specifications steel lintel
lintel as per frame
manufacturer's specifications
FFL 0
as per B.C.A
Living Lower: 29.56 sqm
waffle slab & footings to
penetration pipe with foam lagging
engineer's specifications Living Upper: 119.98 sqm
installed in accordance with B.C.A
Garage: 36.08 sqm
Detail 1 N.T.S Porch: 3.98 sqm
Alfresco: 12.31 sqm
Total: 201.91 sqm
South
North
East
230 1,000
6,060 1,950
col. conc.
2,628 2,628 2,628 1,050 above
1,000
cl cl cl cl
625
3,715 900
cl
70
70
shower recess
into joists
2,040
900
900
2,893
4,810
6,070
70 900 shower recess FFL RL 7.810
into joists PAD RL 7.500
CL
to
col. conc.
1,100
25mm rebate for garage
CL
door opening
26
cl
,7
11
1,600 350
10,440
10,440
275
310
12
,60
310
lbw
90
3
2,893
350
1,080
86mm col. conc.
1,010
1,000
lbw stepdown 1,000
150 70
cl
3,730 lbw
70
350
2,000
shs to eng. spec. 380 1,500 970
3,140
3,370
2,893
stepdown
floor joists @ 450 cts.
86mm
3,020
lbw
as per engineers documentation
695 705
fw
col. conc.
cl
footings / shs columns
poured & positioned at same time as main slab cl cl cl cl
1,500
2,628 2,628 2,628 1,050 col. conc.
1,100 4,695
Bearers & joists 1,400 3,600 2,060
As specified by engineer designed & fixed in accordance Under Slab Points 7,060
with manufacturer's specifications & tie down details fw 7,060 950
Floor Waste
16,045
Area Calculations
Living Lower: 29.56 sqm
Living Upper: 119.98 sqm
Garage: 36.08 sqm
Porch: 3.98 sqm
Alfresco: 12.31 sqm
Total: 201.91 sqm
South
m/box
North
water proof sgpo for
wp
gas HWS East
HWS
sgpo on ceiling for
garage door motor
W/M/S
1500
300
Laundry Bench @ 1050 AFL
Round Oyster Fluro Light Point - 36w
Washing Machine @ 1500 AFL
Wall mounted flood light point - 120w
Ventilation to internal wc, bath, ensuite
Exhaust Fan on separate switch control to be an exhaust fan in accordance with
vented into ceiling space
BCA F5.4 & AS - 1668.2
MO&O RH REF
Exhaust Fan on light switch control
1050
vented externally unless stated otherwise 900 P'TRY 900
1800 1050 1500
F/S 900 300 1050
Phone point
total allowance Actual Watts
T.V Point Artifical lighting (watts) total used DW
a/c ext.
300
1050
300
300
a/c int.
Ceiling fan Class 1 building (5w/m2) 985 (watts) 696 (watts)
300
300
a/c int. Air Conditioner - Internal Unit
300
a/c ext. Air Conditioner - External Unit
300
300
two-way
two-way
300
wp
300 300
a/c int. Area Calculations
4
a/c ext.
3 Living Lower: 29.56 sqm
2
1 Living Upper: 119.98 sqm
UP Garage: 36.08 sqm
Porch: 3.98 sqm
Alfresco: 12.31 sqm
Total: 201.91 sqm
South
North
Bracing Notes 900 Ply 900 Ply
East
450 Ply
not part of calculation
900 Ply
BRACING TYPES USED:
Type (h) Method B - Plywood
-Minimum length of panels may be 600mm
-Plywood shall be fixed to frame in a/w AS1684.2 using 30 x 2.8mm diam. galvanized flathead nails or equivalent
-Fastener spacing; top and bottom plate 150mm, vertical edges 150mm, intermediate studs 300mm
900 Ply
-Bracing capacity of Type (h) Method B is 6.0kN/m
900 Ply
-Length of bracing 1800mm min. to 2700mm max.
-Bracing capacity of Type (d) is 3.0kN/m Upper Level - 11.92 kN Required Upper Level - 41.16 kN Required
-Metal angle of min. nominal section of 18 x 16 x 1.2mm must be fixed to frame in a/w AS1684.2
-2/30 x 2.8mm diam. nails to each stud
-30 x 0.8mm galv. strap 3/30 x 2.8mm diam. galv. flathead (or equivalent) nails to each end to stud Direction X N2 Sheet Roof Direction Y N2 Sheet Roof
Type Length Resistance Qty. Total (kN) Type Length Resistance Qty. Total (kN)
Ply Brace 600 6.0 kN/lm Ply Brace 600 6.0 kN/lm 01 3.6
STRUCTURAL BRACING:
-For wall heights greater than 2700mm the bracing capacity of bracing walls is reduced and must Ply Brace 900 6.0 kN/lm 05 27.00 Ply Brace 900 6.0 kN/lm 07 37.80
450 Ply
be recalculated using the values given in Table 8.1.9 of AS1684.2/AS1684.3. not part of calculation Metal Strapping Metal Strapping
-Bracing shall initially be placed in external walls and where possible at the corners of the building. 2000 3.0 kN/lm 2000 3.0 kN/lm
(double cross) (double cross)
Remaining bracing shall be evenly distributed throughout building. 900 Ply
-Bracing shall not be placed on external walls under the eaves unless suitable connections to the
900 Ply
Total Resistance Achieved 27.00 Total Resistance Achieved 41.40
main ceiling diaphragms are provided.
900 Ply
-The maximum distance between braced walls at right angles to the building length/width shall not
exceed 9000mm for wind classification N2. For wind classification greater than N2 spacing shall be Lower Level - 32.68 kN Required Lower Level - 45.20 kN Required
900 Ply
600 Ply
in accordance with Table 8.20 and 8.21 in AS1684.2./AS1864.3.
-All internal bracing walls shall be fixed to the floor, ceiling and/or external wall frame with
structural connections of equivalent shear capacity to the bracing capacity of that particular bracing Direction X N2 Sheet Roof Direction Y N2 Sheet Roof
900 Ply
wall.
900 Ply
900 Ply
600 Ply
TEMPORARY BRACING NOTES: Ply Brace 900 6.0 kN/lm 06 32.40 Ply Brace 900 6.0 kN/lm 08 43.20
-The builder is to ensure that the building is adequately braced during construction.
Metal Strapping Metal Strapping
-Temporary bracing shall be equivalent to at least 60% of the permanent bracing required. 2000 3.0 kN/lm 2000 3.0 kN/lm
-Temporary bracing may form part of the installed permanent bracing. (double cross) (double cross)
900 Ply
Total Resistance Achieved 32.40 Total Resistance Achieved 50.40
NOMINAL WALL BRACING:
Lower Level
-Nominal bracing, wall frames lined with sheet material such as plywood, plasterboard or fibre
cement, may provide up to 50% resistance of the total racking forces. X - Total Required - 44.60 kN Y - Total Required - 86.36 kN
-Wall frames must be nominally fixed to the floor and roof frame.
-Nominal bracing shall be evenly distributed throughout the building. X - Total Achieved - 59.40 kN Y - Total Achieved -97.80 kN
-Minimum length of nominal bracing walls shall be 450mm.
-Sheeted one side only: Bracing capacity 0.45kN/m
-Sheeted two sides: Bracing capacity 0.75kN/m
-1/75mm masonry nail, screw or bolt @1200 crs max.
Direction - Y
900 Ply 900 Ply
900 Ply
900 Ply
Tie-Down Schedule
-Nominal fixings to all timber members in accordance with relevant standards; AS1684.2, AS1684.3
-M12 Cyclone rods to either side of external openings over 1800mm wide for N1, N2, N3 Sheet roofing
N2
BATTENS / TRUSSES
900 Ply
-1/No 14 Type 17 x 75mm screws, or as per truss manufacturer's specifications
TRUSS / TOP PLATE 900 Ply
-1/30 x 0.8mm G.I. strap over each truss, 4/2.8mm diam. nails each end
-Girder truss to have 2/30 x 0.8mm G.I. straps, 4/2.8mm diam nails each end
LINTEL / TOP PLATE
Sheet Roof
-30 X 0.8mm looped strap @900 crs max, 4 nails each end
Direction - X
LINTEL / JAMB STUD
-30 x 0.8mm G.I. strap @900 crs max, 4/2.8mm diam. nails each end 44.60 Kn Bracing Required
BOTTOM PLATE / CONCRETE SLAB
900 Ply
900 Ply
900 Ply
-1/75mm masonry nail, screw or bolt @1200 crs max.
59.40 Kn Bracing Achieved
900 Ply
Area Calculations
Living Lower: 29.56 sqm
Living Upper: 119.98 sqm
Upper Level
Garage: 36.08 sqm
600 Ply
900 Ply
Porch: 3.98 sqm
Alfresco: 12.31 sqm
Total: 201.91 sqm
South
coloured concrete
North
river pebbles (20 - 40mm, weed mat under)
2D Plant East
Symbol
Garden Mulch
Waterhousia Syzguim Lxora Liriope Dietes
Name
Floribunda Australe Coccinea "Evergreen Giant" Bicolor
'A' grade turf
Pot Size 45l 200ml 200ml 140ml 140ml
Width 3.5m 1.5-2.0m 2.0m 0.8m 1.0m paved garden edging to front / timber to rear
Height 8m 0.5-1.0m 0.5-1.0m 0.6m 0.8m
1800mm high timber fence
All plant species & quantities are indicative and subject to availability and suitability to site. Should a
particular nominated plant not be available an equilavant replacement shall be used.
1500mm high timber top
rail & posts with pool
style infill fencing
denotes batter
rock retaining wall
Pla gor
LOT 2406
374 M2
ce
Gre
gate
Mc
rock retaining wall
max height 1m
Area Calculations
Living Lower: 29.56 sqm
Living Upper: 119.98 sqm
Garage: 36.08 sqm
Porch: 3.98 sqm
Alfresco: 12.31 sqm