Working Drawings

Issue Date Description

1 Cover Sheet N/A


2 Legends / Notes N/A
3 Site Plan 1:200 @ A3
4 Floor Plan - Upper 1:100 @ A3
5 Floor Plan - Lower 1:100 @ A3
6 Elevations 1 of 2 1:100 @ A3
7 Elevations 2 of 2 1:100 @ A3
8 Sections / Details as per dwg.
Proposed New Residence For:
9 Slab Layout 1:100 @ A3
10 Electrical Plan 1:100 @ A3
xxx
11 Bracing Plan 1:100 @ A3 xxx
12 Landscaping Plan 1:200 @ A3

Example Working Drawings


NOTES:
Sloping Site
Images Are Diagramatic Only
Refer To Elevations For Details
ALL WORKS SHALL COMPLY WITH BUT NOT LIMITED TO THE BUILDING
CODE OF AUSTRALIAN AND THE CURRENT AUSTRALIAN STANDARDS

General Notes Construction Notes Articulation Joints


This building has been designed in accordance with the current building code of
australia, building act ammendment & australian standards (a) Verticle articulations joints must be provided in unreinforced masonry walls except where the site soli classification is A or S
• Dishwasher provision under sink drainer including cold water connection & GPO Roofing Colorbond sheet, Pitch as specified on drawings
b) Articulation joints between masonry elements must have a width not less than 10 mm and be provided (see Figures 3.3.1.7
• Ventilation to internal wc / bath to be an exhaust fan in accordance with BCA F5.4 & AS - 1668.2 and 3.3.1.8)-
Ceiling Height As specified on drawings
• O/head cupboards to 2250mm AFL with MDF bulkhead over (i) in straight, continuous walls having no openings, at not more than 6 m centres and not closer than the height of
• All openings to have 2100mm AFL Joinery Level As specified on drawings the wall away from corners; and
(ii) where the height of the wall changes by more than 20%, at the position of change in height; and
• Robe fitout (1) shelf with hanging rail Footings To engineers design & detail (iii) where openings more than 900x900 mm occur, at not more than 5 m centres, and positioned in line with one edge
• PVC Downpipes of the opening; and
Slab Height To engineers design & detail
• Lift off hinges to w/c, Ensuite, Bathroom (iv) where walls change in thickness; and
In accordance with BCA volume 2, 3.1.3 termite risk (v) at control or construction joints in footing slabs; and
• Dimensions are to be verified prior to commencement of work Termite Management
management and A.S. 3660.1/1995
(vi) at junctions of walls constructed of different masonry materials; and
• Given dimensions are to have priority to scaled dimensions
External Walls - Brick Veneer 230mm - 110mm Brickwork, 50mm Cavity, 70mm Timber Studs (vii) at deep chases (rebates) for service pipes.
• All stairs are to have 190mm maximum risers and 240mm minimum goings
Internal Linings 10mm Plasterboard
• All wet areas to be in accordance with the current Building Code of Australia 3.8.1 & current AS. (c) For all articulation joints in cavity walls, extendable masonry anchors must be built in at every fourth course (see Figure
6 mm Villaboard to all wet areas
• Floor wastes to wet areas 3.3.1.9). For veneer construction the extendable ties may be omitted.
Ceiling Linings 10mm Plasterboard
Denotes Smoke Detector (d) For single leaf masonry walls stabilised by return walls, or engaged piers, any articulation joints must be within 300 mm of
Soffit Linings 4.5mm Hardiflex the vertical support (see Figures 3.3.1.3 and 3.3.1.4(b)).
(e) Where masonry is required to be waterproof all joints must be sealed with a flexible, compressible material (see Figure
Site Notes Window Flashing To All Windows. As per manufacturers details
3.3.1.9).
Roof Bracing Speed Brace. As per manufacturers details (f) Articulation joints must not be constructed adjacent to arched openings.
• Contractor to verify all boundary clearances & site set-out dimensions prior to commencement of construction Fascia Metal Fascia Fixed To Standard Rafter Bracket, (g) Articulation joints must not be located in unreinforced masonry above garage door openings or the like unless the panel of
Complete With Mitre Angles, Joining Sleeves Etc masonry is laterally supported with masonry ties or other suitable means.
• Levels & contours are based on assumed datum. Prior to construction the relevant authority should be
Downpipes PVC
contacted for possible minimum floor level requirements & flood information
• Retaining walls greater than 1m high (cut or fill) are required to be engineer designed & certified Guttering Colorbond
• Batters to comply appropriate soil classification described in table 3.1.1.1. BCA Vol.2. DEVELOPMENT NEAR UNDERGROUND UTILITY SERVICES
Smoke Alarms To Be Hard Wire Installed In Accordance With Part 3.7.2 Of The B.C.A.
• Vehicular cross-over to be constructed as per local council requirements and/or approval For the purpose of this section of the table:
• Driveways, paths, porch, alfresco area finish as per specifications Timber Schedule
• Scrape away vegetation & cut & fill to provide a level building platform · An approval that has been granted to the development pursuant to Section 823 of the
Note: all timber sizes are based on the current timber engineering code AS 1720. Water Act 2000 is deemed to satisfy the Performance Criteria of this section.4
• Finish surface to be graded away from house at minimum of 1:20 for at least 1m All member types are analyzed using limit state principles incorporatings the · “Access Cover” means a removable cover to provide access for cleaning or inspection of
• Surface water to be channelled to council stormwater drainage system latest timber technology available. All of the member types accessible using sewers, stormwater drains and water mains.
• The driveway & pathways indicated on plan are suggested layouts timber sizes meet the loading and serviceability criteria outlined in AS 1170.1 saa · “Associated Structure” includes a sewer or stormwater manhole, a water meter and a fire
loading code and as 1684.2 - 2010 - residential timber-framed construction - part hydrant.
• All ground levels are approximate only 1 - design criteria. All timber framing to be in accordance with AS 1684.3-2010 · “Building” has the meaning defined in the Building Act 1975.
• All works to be constructed in accordance with the current Building Code of Australia, · “Connection Point” has the meaning defined in the Standard Sewerage Law.
the current Australian Standards and all relevant current trade & technical manuals Wall Framing Seasoned Pine · “Invert Level” means the bottom level of the inside of the pipe or drain.
· “Manhole” means an access chamber being a below Ground Level structure, with a cover,
Top Plate
(Load Bearing)
2 / 35 X 70 (MGP 12) built in the line of a sewer or stormwater drain, through which a person may access the
Stormwater / Drainage Notes ·
sewer or stormwater drain.
“Sewer” includes sanitary drain jump-ups and capped slope junctions and manholes.
Bottom Plate 35 X 70 (MGP 12)
(Load Bearing) · “Structure’ includes a masonry fence, deck, pergola, satellite dish, water storage tank and
• Drainage to be in accordance with part 3 of the BCA. Point to meet local authority requirements a retaining wall (of greater than 1 metre in Height).
• All plumbing & draining is to comply with the standard sewerage by-laws & requirements of the local authority Bottom Plate · “Zone of Influence” means the area shown on the following diagram:
35 X 70 (MGP 10)
(Non Load Bearing)
• All downpipes to be installed in accordance the current Building Code of Australia 3.5.2.5,
each downpipe must not serve more than 12m of gutter length Studs
(Load Bearing)
35 X 70 (MGP 12) @ 450 cts.
• Stormwater system to local authority requirements ( owner / applicant / builder to ensure no storm water Legend WMS
W.I.R
Washing Machine Space
Walk-in-Robe
runoff occurs onto adjoining properties, back onto any structures & no ponding under sub floor areas Studs
(Non Load Bearing) 35 X 70 (MGP 10) @ 600 cts. (max. height 3000mm) SGD Sliding Glass Door
• Stormwater approval for legal discharge to be obtained from local authority prior to work commencing.
BCA Building Code of Australia SW Aluminum Sliding Window
Discharge is proposed to: kerb & channel, rubble pit to council requirements, inter allotment drainage, DH Aluminum Double Hung Window
Nogging: 35 X 70 (MGP 10) AS Australian Standards
storm water service main, canal or river. DP Downpipe AW Aluminum Awning Window
Jam studs: Beside open. up to 1400mm wide 2 / 35 X 70 (MGP 12) HWS Hot Water System LV Aluminum Louvre Window
Beside open. up to 2300mm wide 3 / 35 X 70 (MGP 12) SHS Steel Post FG Fixed Glass
Beside open. up to 3300mm wide 4 / 35 X 70 (MGP 12) SD Service Duct SL Side Light
FW Floor Waste SHR Shower
To comply with BCA 3.12
Energy Efficiency (unless otherwise stated) Roof framing: Prefabricated timber roof trusses @ specified 600 cts.
T.B.C To Be Confirmed TR
TRH
Towel Rail
Toilet Roll Holder
R.L Relative Level
Trusses to be engineer designed & fixed in accordance with
AS PER ENERGY RATING ASSESSMENT CERTIFICATE
manufacturer's specifications & tie down details AFL Above Floor Level VSD Vinyl Sliding Door Area Calculations
NGL Natural Ground Level MSD Mirrored Sliding Door
Lintels & beams: As specified by engineer designed & fixed in accordance Living Lower: 29.56 sqm
FGL Finished Ground Level CSD Cavity Sliding Door
with manufacturer's specifications & tie down details Living Upper: 119.98 sqm
OHC Overhead Cupboard RW Rainwater Line
Bearers & joists As specified by engineer designed & fixed in accordance UBO Under Bench Oven DW Dishwasher Provision Garage: 36.08 sqm
with manufacturer's specifications & tie down details WO Wall Oven MO Microwave Provision
Porch: 3.98 sqm
Alfresco: 12.31 sqm
Total: 201.91 sqm

T: (07) 5602 6177 0408 701 623


We reserve the right to alter designs, colours and Please Read Carefully Client: Title: Plot Date: 6/07/2015 Drawing No: Issue: Scale: N/A
specifications without notice. Whilst every care has
This plan certified correct is the one referred to in the contract &
W: www.thehousedesigners.com.au been taken in the preparation of this document, the
particulars contained herein are not to be constructed specifications and I understand change hereafter may not be
xxx Legends / Notes o
Job N : 2 of 12 Designed By: MB
A: 1 / 7 Straithaird Road Bundall QLD 4217 as any respresentation of fact. All information provided to
possible. These plans supercede all other previous plans or sketches. Design Name:
P: Po box 3282 Nerang DC QLD 4210
us is from reputable sources and no responsibility is
accepted by the vendor, it's servants or agents for any errors
xxx Drawn By: MB
Owner / s ..............................................................Date...................
or omissions. All interested parties should make their own
Outrigger 201 Working Drawings
QBCC: 1274038 enquiries to satisfy themselves in relation to all matters. Owner / s ..............................................................Date................... Checked By: MB
© The House Designers. The copyright of these floor plans are owned by The House Designers. The floor plans may not be reproduced, copied or dealt with in any manner which infringes the exclusive rights of The House Designers. Upon receiving payment in full, the client receives permission for single use.
South west Site Notes:

• length of all retaining walls t.b.c on site by supervisor

North
• retaining walls higher than 1m in height to be engineered designed
East • retaining walls constructed from treated pine timber or rock as per plans
• agriculture drainage systems to be used
• retaining walls may change location at supervisor's discrection if required
• fencing in accordance with developer covenants
• landscaping in accordance with developer covenants
• driveway gradient not to exceed 1:5
• Batters to comply appropriate soil classification described in table 3.1.1.1.BCA Vol.2.
• stormwater to legal point of dishcharge

Legend
denotes batter

CO
rock retaining wall

MMUN
ELECT
timber retaining wall
tiered rock retaining wall
max height 1m 1 0 .1 6
Lot 2405 direction of fall

IC A T IO
R IC IT Y P IT
FGL 17.500 Proposed FGL RL

10 .0 9

1 0 .0

9 .5 0
11 .7 5

8 .5 0
12 .2 5
7 .5 0

11 .2 5
7 .5 3

10 .0 8

9 .0 0

8.00 7.75
10 .7 5

NS
P IL L A R
BANK

10 .0 5

0
TOP OF
1.8m high fence return

10.07

9.75
10.2

9.25
NGL RL

8.25
S

8.75
16.65
1m back from front building line
10 .00

5
11.0

RO
10.5
12 .0 0

11 .5 0
12 .5 0

stormwater to legal dp Downpipe Location

OFW
7 .3

IT
0
5
9.7 5
point of discharge
7 .2 5

CP

ATE
RW Roof Water Line
Lot 2409

LIG
R IL
12.53 9.50

1,500
Stormwater Line

9.3 3

9.35

H
6 .8
30.127
9.42
347°09'55"

TP
7 .0 8

5
S Sewer Line

OLE
EPI S

6 .9 2
L
OP

7.05

6.96

OP
6 .9
7 .0

2,550
RW
0
RW 1800mm high
RW 7 .0 0
9.23

9
coloured concrete driveway finish timber fence
12.41 m/box

ELP
9.50

7.25
7.50
7.75

1,500
8.00
8.25
8.50
8.75
9.00
9 .2 5
590X350 rendered
9

HWS
dp HTB
31
brick piers
dp fill dismantle existing footpath painted horizontal
9.37 cut
14.0

11.6 7
6.89
S
replace with coloured concrete timber battens
6 .8

R L 6 .8 1 K E R B
6
FFL RL 10.570 0

N A IL INE N C H M A R K
S IT E B
1500mm high timber top
tiered rock retaining wall
6.75

78
PAD (FGL) 9.600 approx. FFL RL 7.810 rail & posts with pool
max height 1m style infill fencing
9.25 PAD RL 7.500

(A r b it r

10,440
11 6 .6
2

G
L
.7 7 Single timber gate

CO
257°09'55"

6 .6

NC

ary)
3,850 fill L Rendered Leterbox

2
cut

6 .7
9.32
9

R B Rubbish Bin Location

5
6.88 S
Lot 2408

Pla gor
103
17

LOT 2406 Real Property Description

°0 9
11.74

3,5

'3 5
374 M2 59
9 .2 5

6 .5

6
10.7 5

"
11.63 11
Lot Number: 2406

ce
Gre
11 .5 0 .0 0

59
6.5 0
11 .2 5 10 dp Registered Plan Number: SP 230012

15.
.2 5 1
6 .3
0 .5
gate
S

2,060
9.10

57
dp Parish: Stapylton
9 .1 1
RW RW RW
10 0
9.26

6
.0 0
7 .0 0

9 .2 County: Stanley

Mc
10.1

6 .3
2

6 .4
OP 6 .5

2
Local Authority: Ipswitch C.C

0
9

WM
9 .7 23.3 167°09'55" OP
1,770

6 .6 5
9 .5 5

FH
6 .2
6
0
9 7 .2
Site Area: 374M2
9 .0 .2 5 8 .0 0
stormwater to legal
8 .7 8 .5
7.20

WM
8 .2 7 .7 5 5
rock retaining wall S
7.74

0 5 0 5 7 .5 0
9.05

6 .1
6
Site Coverage: 40%
max height 1m point of discharge

S L 6 .3 6 M E T E R
WATE
F IR E H
rock retaining wall 1.8m high fence & gate return Driveway Gradient

R
max height 1m 1m back from front building line Grade 1:8

YDRAN
Grade 1:8 1:4 1:8
Transitional
4,300 16,045 2,955 Distance n/a n/a n/a
NGL (boundary) R.L 6.800

T
FFL R.L 7.810
Height Gain 1.01 m
Distance 8.3 m

Lot 2407
Area Calculations
Living Lower: 29.56 sqm
Living Upper: 119.98 sqm
Garage: 36.08 sqm
Porch: 3.98 sqm
Alfresco: 12.31 sqm
Total: 201.91 sqm

T: (07) 5602 6177 0408 701 623


We reserve the right to alter designs, colours and Please Read Carefully Client: Title: Plot Date: 6/07/2015 Drawing No: Issue: Scale: 1:200 @ A3
specifications without notice. Whilst every care has
This plan certified correct is the one referred to in the contract &
W: www.thehousedesigners.com.au been taken in the preparation of this document, the
particulars contained herein are not to be constructed specifications and I understand change hereafter may not be
xxx Site Plan o
Job N : 3 of 12 Designed By: MB
A: 1 / 7 Straithaird Road Bundall QLD 4217 as any respresentation of fact. All information provided to
possible. These plans supercede all other previous plans or sketches. Design Name:
P: Po box 3282 Nerang DC QLD 4210
us is from reputable sources and no responsibility is
accepted by the vendor, it's servants or agents for any errors
xxx Drawn By: MB
Owner / s ..............................................................Date...................
or omissions. All interested parties should make their own
Outrigger 201 Working Drawings
QBCC: 1274038 enquiries to satisfy themselves in relation to all matters. Owner / s ..............................................................Date................... Checked By: MB
© The House Designers. The copyright of these floor plans are owned by The House Designers. The floor plans may not be reproduced, copied or dealt with in any manner which infringes the exclusive rights of The House Designers. Upon receiving payment in full, the client receives permission for single use.
Note: west

• Lift off hinges to wc door

South
• Provide gpo & cold water tap provisions to d/w space

North
• Continuous flow hws, position to be confirmed
• Mechanically vent rooms without natural ventilation
East
• All shower roses to be AAA rated
• Water pressure limited to 500KPa at the meter
• All ground drains to be > 1000mm from gas bottle location
• Nogging to be positioned where indicated in bathroom at
1100 afl for fixing of towel rail (TR) 8,010
• Handrail to be fixed to one side of all stairways (1000mm or higher only)
• Water connection to fridge space at 1900mm afl 6,060 1,950
• Opening windows in bedrooms with fall height of 2m or greater to be restricted 230 5,600 230 1,600 350
to max. 125mm opening (Sliding windows with keyed vent locks;
awning with ratchet restriction) 230 4,600 230 1,000
1,000

1,000
line of building above
col. conc. tap
dp
m/box

230

230
820
HWS

2148 o/h sectional


door (remote)
Garage

5,610
6,070
5,610
plain conc.

7,010
porch ceiling framed
Stair Specification
Rise 2760
to soffit height
Riser 184 (15) 160
70 230 brickwork above
Going 250
plumbing duct steel lintel
10,440

10,440
2RG 618

70

350

230
160
90
90

90
2 1 820 CSD
90

1,080
820

230

1,010

1,000
1,000
1,300

1,300
Porch

220
UP
col. conc.
3
70

4
70

70
70
3,290

820

1,500 VSD
70 1,590

230
820
6

350
Linen
70 930

930
7

1815 XO/OO SW
8 door height to suit

shlvs
store

70

3,370
Bed 4
3,130

2,910
under 720

1,800 VSD
70

3,020
carpet
L'dry
1,910

1,910
1,470

Robe
trh
920

W/M/S
820

0906 XO SW
230
230
230
230

230
230
OBS dp
exp. agg. dp

A wall mount clothes line

230 1,100 3,500 230 2,950 Elevations


70 70 530
230 1,100 1,000 70
530
3,760 230 950
4
230 2,770 70 70 3,160 230
7,060 950
2 1
8,010 3
Area Calculations
Living Lower: 29.56 sqm
Living Upper: 119.98 sqm
Garage: 36.08 sqm
Porch: 3.98 sqm
Alfresco: 12.31 sqm
Total: 201.91 sqm

T: (07) 5602 6177 0408 701 623


We reserve the right to alter designs, colours and Please Read Carefully Client: Title: Plot Date: 6/07/2015 Drawing No: Issue: Scale: 1:100 @ A3
specifications without notice. Whilst every care has
This plan certified correct is the one referred to in the contract &
W: www.thehousedesigners.com.au been taken in the preparation of this document, the
particulars contained herein are not to be constructed specifications and I understand change hereafter may not be
xxx Floor Plan - Lower o
Job N : 4 of 12 Designed By: MB
A: 1 / 7 Straithaird Road Bundall QLD 4217 as any respresentation of fact. All information provided to
possible. These plans supercede all other previous plans or sketches. Design Name:
P: Po box 3282 Nerang DC QLD 4210
us is from reputable sources and no responsibility is
accepted by the vendor, it's servants or agents for any errors
xxx Drawn By: MB
Owner / s ..............................................................Date...................
or omissions. All interested parties should make their own
Outrigger 201 Working Drawings
QBCC: 1274038 enquiries to satisfy themselves in relation to all matters. Owner / s ..............................................................Date................... Checked By: MB
© The House Designers. The copyright of these floor plans are owned by The House Designers. The floor plans may not be reproduced, copied or dealt with in any manner which infringes the exclusive rights of The House Designers. Upon receiving payment in full, the client receives permission for single use.
west

Note:

South
• Lift off hinges to wc door

North
• Provide gpo & cold water tap provisions to d/w space
• Continuous flow hws, position to be confirmed
East
• Mechanically vent rooms without natural ventilation
• All shower roses to be AAA rated 16,385
• Water pressure limited to 500KPa at the meter
• All ground drains to be > 1000mm from gas bottle location 450 15,485 450
• Nogging to be positioned where indicated in bathroom at 530 70
70 2,150 70 1,500 70 4,100 70 3,000 70 930 70 2,715 70
1100 afl for fixing of towel rail (TR)
• Handrail to be fixed to one side of all stairways (1000mm or higher only) 70 4,220 70 2,700 900 70 3,000 70 4,315 70
• Water connection to fridge space at 1900mm afl 70 530
• Opening windows in bedrooms with fall height of 2m or greater to be restricted 70 4,785 70 1,100 70 4,430 70
to max. 125mm opening (Sliding windows with keyed vent locks;
awning with ratchet restriction) A

spreader
dp dp dp
OBS

70
1215 XO SW 0906 XO SW
water tap @
ohc
450

450
600
70

70

70
70
900 shlvs P'TRY w/o 1900mm afl 900
F/S 900

0906 XO SW

0615 XO SW
1,800 VSD

Robe
OBS
W.I.R m/o prov. trh
1,900 Ens. tr

2,090
1,300
above
Kitchen WC Bath
Bed 2
3,220

3,220
720

720
m/h d/w prov.

plain conc. slab


tiles

720

720
trh

1.1m X 0.5m

shlvs
under carpet

a/c ext.
tr
900
70
800

a/c int.

70
200mm o/hang to benchtop
820

590
70

70
plumbing duct under
0615 XO SW

1215 XO SW
1,000

1,000
Bed 1

160
590
Dining
3,800

3,500
carpet tiles Family
9,680

9,680
70
8,780

8,780
2 tiles 160 600
1
70

70

1,200 VSD

1,300
Linen
1000mm high wall

1,390
3
820
5,940

4
5

3,080

shlvs

70
70
1218 XO SW

820
70

6
7
dp
4,280

Living 8
spreader

1215 XO SW
9

2121 SGD

2,700 VSD
tiles
Alfresco 10
Bed 3

Robe

2,910
2,870

timber decking 11
12
carpet

down

a/c int. 14 13
dp

4 1809 XO/O SW 1809 XO/O SW


70
70

70
a/c ext.
3
2
450

450
plain conc. slab dp
1 1.1m X 0.5m Stair Specification
UP
900mm
down A Rise 2760
Riser 184 (15)
Going 250
2RG 618 Elevations
70 4,220 70 2,700 900 70
70 530 4
70 4,785 70 1,100 70 3,200 70
4,290 9,965 1,230
2 1
450 15,485 450 3
16,385

Area Calculations
Living Lower: 29.56 sqm
Living Upper: 119.98 sqm
Garage: 36.08 sqm
Porch: 3.98 sqm
Alfresco: 12.31 sqm
Total: 201.91 sqm

T: (07) 5602 6177 0408 701 623


We reserve the right to alter designs, colours and Please Read Carefully Client: Title: Plot Date: 6/07/2015 Drawing No: Issue: Scale:
specifications without notice. Whilst every care has
This plan certified correct is the one referred to in the contract &
W: www.thehousedesigners.com.au been taken in the preparation of this document, the
particulars contained herein are not to be constructed specifications and I understand change hereafter may not be
xxx Floor Plan - Upper o
Job N : 5 of 12 Designed By:MB
1:100 @ A3
A: 1 / 7 Straithaird Road Bundall QLD 4217 as any respresentation of fact. All information provided to
possible. These plans supercede all other previous plans or sketches. Design Name:
P: Po box 3282 Nerang DC QLD 4210
us is from reputable sources and no responsibility is
accepted by the vendor, it's servants or agents for any errors
xxx Drawn By: MB
Owner / s ..............................................................Date...................
or omissions. All interested parties should make their own
Outrigger 201 Working Drawings
QBCC: 1274038 enquiries to satisfy themselves in relation to all matters. Owner / s ..............................................................Date................... Checked By: MB
© The House Designers. The copyright of these floor plans are owned by The House Designers. The floor plans may not be reproduced, copied or dealt with in any manner which infringes the exclusive rights of The House Designers. Upon receiving payment in full, the client receives permission for single use.
powder coated aluminium framed
windows and sliding glass doors colorbond sheet roof @ 25°pitch
colorbond fascia & gutter
hardies 325mm wide stria
450 450
450

Bounday

Bounday
UTP 5,200
UJL 4,860

7,637
hardies 133mm wide axon

UFFL 2,760
TP 2,440
JL 2,100

3,000

3,000
meter box
wall hung clothes line

rendered brickwork
FFL 0

350sq. rendered brick pier 2148 remote garage


core filled with 1/M12 rod typical door to build. spec.

Elevation 1

powder coated aluminium framed


windows and sliding glass doors 450
colorbond sheet roof @ 25°pitch
450 colorbond fascia & gutter

UTP 5,200
UJL 4,860

1000mm high balustrading


hardies 325mm wide stria to build. spec.

steps
UFFL 2,760

a/c

shs columns to eng. spec.

Area Calculations
Note: Living Lower: 29.56 sqm
• Refer to colour specifications for detailed internal and external colours / materials Living Upper: 119.98 sqm
Elevation 2 • Articulation joints as per engineering details Garage: 36.08 sqm
Porch: 3.98 sqm
• All opening windows with fall height of 2m or greater to be restricted to max. 125mm opening
Alfresco: 12.31 sqm
(Sliding windows with keyed vent locks; awning with ratchet restriction)
Total: 201.91 sqm

T: (07) 5602 6177 0408 701 623


We reserve the right to alter designs, colours and Please Read Carefully Client: Title: Plot Date: 6/07/2015 Drawing No: Issue: Scale: 1:100 @ A3
specifications without notice. Whilst every care has
This plan certified correct is the one referred to in the contract &
W: www.thehousedesigners.com.au been taken in the preparation of this document, the
particulars contained herein are not to be constructed specifications and I understand change hereafter may not be
xxx Elevations 1 of 2 o
Job N : 6 of 12 Designed By: MB
A: 1 / 7 Straithaird Road Bundall QLD 4217 as any respresentation of fact. All information provided to
possible. These plans supercede all other previous plans or sketches. Design Name:
P: Po box 3282 Nerang DC QLD 4210
us is from reputable sources and no responsibility is
accepted by the vendor, it's servants or agents for any errors
xxx Drawn By: MB
Owner / s ..............................................................Date...................
or omissions. All interested parties should make their own
Outrigger 201 Working Drawings
QBCC: 1274038 enquiries to satisfy themselves in relation to all matters. Owner / s ..............................................................Date................... Checked By: MB
© The House Designers. The copyright of these floor plans are owned by The House Designers. The floor plans may not be reproduced, copied or dealt with in any manner which infringes the exclusive rights of The House Designers. Upon receiving payment in full, the client receives permission for single use.
HWS (gas)
FGL
NGL

Bounday

Bounday
powder coated aluminium framed
windows and sliding glass doors 450
450
colorbond sheet roof @ 25°pitch
450 colorbond fascia & gutter

tiered rock retaining wall UTP 5,200


max. height 1m UJL 4,860
hardies 325mm
wide stria hardies 133mm wide axon

NGL a/c unit

UFFL 2,760
TP 2,440
a/c JL 2,100
HWS (gas)

3,000
rendered brick section
steps NGL core filled with 1/M12 rod typical
1000mm high balustrading
to build. spec.

FFL 0
shs columns to eng. spec.
NGL
wall hung clothes line

Elevation 3

powder coated aluminium framed


colorbond sheet roof @ 25°pitch
windows and sliding glass doors
colorbond fascia & gutter

450 450

Bounday
UTP 5,200
Bounday

UJL 4,860

hardies 325mm wide stria

a/c unit
UFFL 2,760
TP 2,440 NGL
tiered rock retaining wall
JL 2,100 max. height 1m
3,000

3,000

FGL
350sq. rendered brick pier NGL
FGL
core filled with 1/M12 rod typical
m/box
shs columns to eng. spec.
FFL 0

NGL Area Calculations


HWS (gas)
Note: Living Lower: 29.56 sqm
• Refer to colour specifications for detailed internal and external colours / materials Living Upper: 119.98 sqm
Elevation 4 • Articulation joints as per engineering details Garage: 36.08 sqm
Porch: 3.98 sqm
• All opening windows with fall height of 2m or greater to be restricted to max. 125mm opening
Alfresco: 12.31 sqm
(Sliding windows with keyed vent locks; awning with ratchet restriction)
Total: 201.91 sqm

T: (07) 5602 6177 0408 701 623


We reserve the right to alter designs, colours and Please Read Carefully Client: Title: Plot Date: 6/07/2015 Drawing No: Issue: Scale: 1:100 @ A3
specifications without notice. Whilst every care has
This plan certified correct is the one referred to in the contract &
W: www.thehousedesigners.com.au been taken in the preparation of this document, the
particulars contained herein are not to be constructed specifications and I understand change hereafter may not be
xxx Elevations 2 of 2 o
Job N : 7 of 12 Designed By: MB
A: 1 / 7 Straithaird Road Bundall QLD 4217 as any respresentation of fact. All information provided to
possible. These plans supercede all other previous plans or sketches. Design Name:
P: Po box 3282 Nerang DC QLD 4210
us is from reputable sources and no responsibility is
accepted by the vendor, it's servants or agents for any errors
xxx Drawn By: MB
Owner / s ..............................................................Date...................
or omissions. All interested parties should make their own
Outrigger 201 Working Drawings
QBCC: 1274038 enquiries to satisfy themselves in relation to all matters. Owner / s ..............................................................Date................... Checked By: MB
© The House Designers. The copyright of these floor plans are owned by The House Designers. The floor plans may not be reproduced, copied or dealt with in any manner which infringes the exclusive rights of The House Designers. Upon receiving payment in full, the client receives permission for single use.
prefabricated timber roof trusses @ 600 cts.
trusses to be engineer designed & fixed in accordance
ROOF PITCH AS PER PLANS with manufacturer's specifications & tie down details

selected colorbond sheeting

10mm plasterboard lining to ceilings fixed 1/30x0.8 G.I. strap


to metal furring channels a @450 cts roof battens @ 900 cts (intermittent safety battens)
to manufacturer's specifications

50x38 soffit bearers

cornices as per builder's specifications colorbond fascia & gutter


fixed to manufacturer's
lintel as per frame specs.
manufacturer's specifications
FC sheeting to soffit and
above windows

OVERHANG AS PER PLANS


prefabricated timber roof trusses @ 600 cts.
trusses to be designed & fixed in accordance
with manufacturer's specifications & tie down details
2,440

10mm plasterboard linings to ceiling

timber framed walls as colorbond sheet roof @ 25°pitch


per framing schedule colorbond fascia & gutter
lightweight cladding as per plans 5,200
10mm plasterboard wall lining UTP
paint finish UJL 4,860

metal flashing fixed in accordance with


manufacturer's specifications

UFFL 2,760
5,200

320

TP 2,440
JL 2,100 DETAIL 1
10mm plasterboard fixed to
underside of joist
cornices as per builder's
specifications steel lintel
lintel as per frame
manufacturer's specifications
FFL 0

concrete slab & footing to


engineers design & detail

Section A 1:100 @A3


2,440

timber framed walls as


per framing schedule
brick sill
wall ties in accordance with AS
3700 Masonary code brick sill flashing / weep hole

10mm plasterboard wall lining


paint finish
polystyrene waffle pod
concrete slab & footings to weepholes @ 900mm cts
engineer's detail & design
damp proof course installation
as per the current B.C.A.
(minimum height of 75mm above finished surface level)

slab edge exposure, visual termite risk management (vertical)


minimum height of 75mm above finished surface level Area Calculations
75

as per B.C.A
Living Lower: 29.56 sqm
waffle slab & footings to
penetration pipe with foam lagging
engineer's specifications Living Upper: 119.98 sqm
installed in accordance with B.C.A
Garage: 36.08 sqm
Detail 1 N.T.S Porch: 3.98 sqm
Alfresco: 12.31 sqm
Total: 201.91 sqm

T: (07) 5602 6177 0408 701 623


We reserve the right to alter designs, colours and Please Read Carefully Client: Title: Plot Date: 6/07/2015 Drawing No: Issue: Scale: as per dwg
specifications without notice. Whilst every care has
This plan certified correct is the one referred to in the contract &
W: www.thehousedesigners.com.au been taken in the preparation of this document, the
particulars contained herein are not to be constructed specifications and I understand change hereafter may not be
xxx Sections / Details o
Job N : 8 of 12 Designed By: MB
A: 1 / 7 Straithaird Road Bundall QLD 4217 as any respresentation of fact. All information provided to
possible. These plans supercede all other previous plans or sketches. Design Name:
P: Po box 3282 Nerang DC QLD 4210
us is from reputable sources and no responsibility is
accepted by the vendor, it's servants or agents for any errors
xxx Drawn By: MB
Owner / s ..............................................................Date...................
or omissions. All interested parties should make their own
Outrigger 201 Working Drawings
QBCC: 1274038 enquiries to satisfy themselves in relation to all matters. Owner / s ..............................................................Date................... Checked By: MB
© The House Designers. The copyright of these floor plans are owned by The House Designers. The floor plans may not be reproduced, copied or dealt with in any manner which infringes the exclusive rights of The House Designers. Upon receiving payment in full, the client receives permission for single use.
west

South

North
East

230 1,000
6,060 1,950

col. conc.
2,628 2,628 2,628 1,050 above

1,000
cl cl cl cl

500 bearers as per as per 86mm


engineers documentation stepdown

625
3,715 900
cl

70

70
shower recess
into joists

2,040

900

900
2,893

4,810

6,070
70 900 shower recess FFL RL 7.810
into joists PAD RL 7.500

CL
to
col. conc.

1,100
25mm rebate for garage

CL
door opening

26
cl

,7
11
1,600 350

10,440

10,440
275
310

12
,60

310
lbw

90

3
2,893

350
1,080
86mm col. conc.

1,010

1,000
lbw stepdown 1,000

150 70
cl
3,730 lbw

70

350
2,000
shs to eng. spec. 380 1,500 970

3,140

3,370
2,893

stepdown
floor joists @ 450 cts.

86mm

3,020
lbw
as per engineers documentation

695 705
fw
col. conc.
cl
footings / shs columns
poured & positioned at same time as main slab cl cl cl cl

1,500
2,628 2,628 2,628 1,050 col. conc.

1,100 4,695
Bearers & joists 1,400 3,600 2,060
As specified by engineer designed & fixed in accordance Under Slab Points 7,060
with manufacturer's specifications & tie down details fw 7,060 950
Floor Waste

16,045

Area Calculations
Living Lower: 29.56 sqm
Living Upper: 119.98 sqm
Garage: 36.08 sqm
Porch: 3.98 sqm
Alfresco: 12.31 sqm
Total: 201.91 sqm

T: (07) 5602 6177 0408 701 623


We reserve the right to alter designs, colours and Please Read Carefully Client: Title: Plot Date: 6/07/2015 Drawing No: Issue: Scale: 1:100 @ A3
specifications without notice. Whilst every care has
This plan certified correct is the one referred to in the contract &
W: www.thehousedesigners.com.au been taken in the preparation of this document, the
particulars contained herein are not to be constructed specifications and I understand change hereafter may not be
xxx Slab Layout o
Job N : 9 of 12 Designed By: MB
A: 1 / 7 Straithaird Road Bundall QLD 4217 as any respresentation of fact. All information provided to
possible. These plans supercede all other previous plans or sketches. Design Name:
P: Po box 3282 Nerang DC QLD 4210
us is from reputable sources and no responsibility is
accepted by the vendor, it's servants or agents for any errors
xxx Drawn By: MB
Owner / s ..............................................................Date...................
or omissions. All interested parties should make their own
Outrigger 201 Working Drawings
QBCC: 1274038 enquiries to satisfy themselves in relation to all matters. Owner / s ..............................................................Date................... Checked By: MB
© The House Designers. The copyright of these floor plans are owned by The House Designers. The floor plans may not be reproduced, copied or dealt with in any manner which infringes the exclusive rights of The House Designers. Upon receiving payment in full, the client receives permission for single use.
west

South
m/box

North
water proof sgpo for

wp
gas HWS East

HWS
sgpo on ceiling for
garage door motor

Electrical Legend Electrical Notes


Lower Level
wp
Double power outlet (water proof)
Light Switches @ 1150 AFL
wp
Single power outlet (water proof) Wall Mounted Lights @ 2000 AFL
Power Outlets (Standard) @ 300 AFL 1500
Single power outlet
Power Outlets (Other)
Double power outlet
Microwave Oven (Oven Tower) @ 1800 AFL two-way
feature downlight point - 18w Microwave Oven (Under Bench) @ 700 AFL
Down light point - 18w (CFL) Kitchen Bench @ 1050 AFL
Down light point - 18w (LED) Refrigerator @ 1500 AFL
Single fluorescent light point - 36w Rangehood @ 1800 AFL

Double fluorescent light point - 36w Dishwasher @ 300 AFL


Vantiy Basins @ 1050 AFL
Smoke detector

W/M/S
1500
300
Laundry Bench @ 1050 AFL
Round Oyster Fluro Light Point - 36w
Washing Machine @ 1500 AFL
Wall mounted flood light point - 120w
Ventilation to internal wc, bath, ensuite
Exhaust Fan on separate switch control to be an exhaust fan in accordance with
vented into ceiling space
BCA F5.4 & AS - 1668.2
MO&O RH REF
Exhaust Fan on light switch control

1050
vented externally unless stated otherwise 900 P'TRY 900
1800 1050 1500
F/S 900 300 1050

Phone point
total allowance Actual Watts
T.V Point Artifical lighting (watts) total used DW

a/c ext.
300

1050
300
300
a/c int.
Ceiling fan Class 1 building (5w/m2) 985 (watts) 696 (watts)
300

Ceiling fan / light


Upper Level

300
a/c int. Air Conditioner - Internal Unit

300
a/c ext. Air Conditioner - External Unit
300
300

two-way
two-way
300
wp

300 300
a/c int. Area Calculations
4
a/c ext.
3 Living Lower: 29.56 sqm
2
1 Living Upper: 119.98 sqm
UP Garage: 36.08 sqm
Porch: 3.98 sqm
Alfresco: 12.31 sqm
Total: 201.91 sqm

T: (07) 5602 6177 0408 701 623


We reserve the right to alter designs, colours and Please Read Carefully Client: Title: Plot Date: 6/07/2015 Drawing No: Issue: Scale: 1:100 @ A3
specifications without notice. Whilst every care has
This plan certified correct is the one referred to in the contract &
W: www.thehousedesigners.com.au been taken in the preparation of this document, the
particulars contained herein are not to be constructed specifications and I understand change hereafter may not be
xxx Electrical Plan o
Job N : 10 of 12 Designed By: MB
A: 1 / 7 Straithaird Road Bundall QLD 4217 as any respresentation of fact. All information provided to
possible. These plans supercede all other previous plans or sketches. Design Name:
P: Po box 3282 Nerang DC QLD 4210
us is from reputable sources and no responsibility is
accepted by the vendor, it's servants or agents for any errors
xxx Drawn By: MB
Owner / s ..............................................................Date...................
or omissions. All interested parties should make their own
Outrigger 201 Working Drawings
QBCC: 1274038 enquiries to satisfy themselves in relation to all matters. Owner / s ..............................................................Date................... Checked By: MB
© The House Designers. The copyright of these floor plans are owned by The House Designers. The floor plans may not be reproduced, copied or dealt with in any manner which infringes the exclusive rights of The House Designers. Upon receiving payment in full, the client receives permission for single use.
west

South

North
Bracing Notes 900 Ply 900 Ply

East

450 Ply
not part of calculation

900 Ply
BRACING TYPES USED:
Type (h) Method B - Plywood
-Minimum length of panels may be 600mm
-Plywood shall be fixed to frame in a/w AS1684.2 using 30 x 2.8mm diam. galvanized flathead nails or equivalent
-Fastener spacing; top and bottom plate 150mm, vertical edges 150mm, intermediate studs 300mm

900 Ply
-Bracing capacity of Type (h) Method B is 6.0kN/m

Type (d) - Metal angle brace


Direction - X Direction - Y
-Maximum depth of notch shall not exceed 20mm

900 Ply
-Length of bracing 1800mm min. to 2700mm max.
-Bracing capacity of Type (d) is 3.0kN/m Upper Level - 11.92 kN Required Upper Level - 41.16 kN Required
-Metal angle of min. nominal section of 18 x 16 x 1.2mm must be fixed to frame in a/w AS1684.2
-2/30 x 2.8mm diam. nails to each stud
-30 x 0.8mm galv. strap 3/30 x 2.8mm diam. galv. flathead (or equivalent) nails to each end to stud Direction X N2 Sheet Roof Direction Y N2 Sheet Roof
Type Length Resistance Qty. Total (kN) Type Length Resistance Qty. Total (kN)
Ply Brace 600 6.0 kN/lm Ply Brace 600 6.0 kN/lm 01 3.6
STRUCTURAL BRACING:
-For wall heights greater than 2700mm the bracing capacity of bracing walls is reduced and must Ply Brace 900 6.0 kN/lm 05 27.00 Ply Brace 900 6.0 kN/lm 07 37.80

450 Ply
be recalculated using the values given in Table 8.1.9 of AS1684.2/AS1684.3. not part of calculation Metal Strapping Metal Strapping
-Bracing shall initially be placed in external walls and where possible at the corners of the building. 2000 3.0 kN/lm 2000 3.0 kN/lm
(double cross) (double cross)
Remaining bracing shall be evenly distributed throughout building. 900 Ply
-Bracing shall not be placed on external walls under the eaves unless suitable connections to the
900 Ply
Total Resistance Achieved 27.00 Total Resistance Achieved 41.40
main ceiling diaphragms are provided.

900 Ply
-The maximum distance between braced walls at right angles to the building length/width shall not
exceed 9000mm for wind classification N2. For wind classification greater than N2 spacing shall be Lower Level - 32.68 kN Required Lower Level - 45.20 kN Required

900 Ply

600 Ply
in accordance with Table 8.20 and 8.21 in AS1684.2./AS1864.3.
-All internal bracing walls shall be fixed to the floor, ceiling and/or external wall frame with
structural connections of equivalent shear capacity to the bracing capacity of that particular bracing Direction X N2 Sheet Roof Direction Y N2 Sheet Roof

900 Ply
wall.

ROOF TRUSSES and ROOF BRACING:


900 Ply Type Length Resistance Qty. Total (kN) Type Length Resistance Qty. Total (kN)
-To be designed by truss manufacturer to comply with AS1684.2, AS1720 and AS4440. 6.0 kN/lm 6.0 kN/lm 02 7.20
Ply Brace 600 Ply Brace 600

900 Ply
900 Ply

600 Ply
TEMPORARY BRACING NOTES: Ply Brace 900 6.0 kN/lm 06 32.40 Ply Brace 900 6.0 kN/lm 08 43.20
-The builder is to ensure that the building is adequately braced during construction.
Metal Strapping Metal Strapping
-Temporary bracing shall be equivalent to at least 60% of the permanent bracing required. 2000 3.0 kN/lm 2000 3.0 kN/lm
-Temporary bracing may form part of the installed permanent bracing. (double cross) (double cross)
900 Ply
Total Resistance Achieved 32.40 Total Resistance Achieved 50.40
NOMINAL WALL BRACING:

Lower Level
-Nominal bracing, wall frames lined with sheet material such as plywood, plasterboard or fibre
cement, may provide up to 50% resistance of the total racking forces. X - Total Required - 44.60 kN Y - Total Required - 86.36 kN
-Wall frames must be nominally fixed to the floor and roof frame.
-Nominal bracing shall be evenly distributed throughout the building. X - Total Achieved - 59.40 kN Y - Total Achieved -97.80 kN
-Minimum length of nominal bracing walls shall be 450mm.
-Sheeted one side only: Bracing capacity 0.45kN/m
-Sheeted two sides: Bracing capacity 0.75kN/m
-1/75mm masonry nail, screw or bolt @1200 crs max.

Direction - Y
900 Ply 900 Ply
900 Ply
900 Ply

Tie-Down Schedule

97.80 Kn Bracing Achieved

86.36 Kn Bracing Required


Denotes Tie-Down Rod
900 Ply

-Nominal fixings to all timber members in accordance with relevant standards; AS1684.2, AS1684.3
-M12 Cyclone rods to either side of external openings over 1800mm wide for N1, N2, N3 Sheet roofing

N2
BATTENS / TRUSSES

900 Ply
-1/No 14 Type 17 x 75mm screws, or as per truss manufacturer's specifications
TRUSS / TOP PLATE 900 Ply
-1/30 x 0.8mm G.I. strap over each truss, 4/2.8mm diam. nails each end
-Girder truss to have 2/30 x 0.8mm G.I. straps, 4/2.8mm diam nails each end
LINTEL / TOP PLATE
Sheet Roof
-30 X 0.8mm looped strap @900 crs max, 4 nails each end

Direction - X
LINTEL / JAMB STUD
-30 x 0.8mm G.I. strap @900 crs max, 4/2.8mm diam. nails each end 44.60 Kn Bracing Required
BOTTOM PLATE / CONCRETE SLAB

900 Ply
900 Ply

900 Ply
-1/75mm masonry nail, screw or bolt @1200 crs max.
59.40 Kn Bracing Achieved
900 Ply

Area Calculations
Living Lower: 29.56 sqm
Living Upper: 119.98 sqm

Upper Level
Garage: 36.08 sqm

600 Ply
900 Ply
Porch: 3.98 sqm
Alfresco: 12.31 sqm
Total: 201.91 sqm

T: (07) 5602 6177 0408 701 623


We reserve the right to alter designs, colours and Please Read Carefully Client: Title: Plot Date: 6/07/2015 Drawing No: Issue: Scale: 1:100 @ A3
specifications without notice. Whilst every care has
This plan certified correct is the one referred to in the contract &
W: www.thehousedesigners.com.au been taken in the preparation of this document, the
particulars contained herein are not to be constructed specifications and I understand change hereafter may not be
xxx Bracing Plan o
Job N : 11 of 12 Designed By: MB
A: 1 / 7 Straithaird Road Bundall QLD 4217 as any respresentation of fact. All information provided to
possible. These plans supercede all other previous plans or sketches. Design Name:
P: Po box 3282 Nerang DC QLD 4210
us is from reputable sources and no responsibility is
accepted by the vendor, it's servants or agents for any errors
xxx Drawn By: MB
Owner / s ..............................................................Date...................
or omissions. All interested parties should make their own
Outrigger 201 Working Drawings
QBCC: 1274038 enquiries to satisfy themselves in relation to all matters. Owner / s ..............................................................Date................... Checked By: MB
© The House Designers. The copyright of these floor plans are owned by The House Designers. The floor plans may not be reproduced, copied or dealt with in any manner which infringes the exclusive rights of The House Designers. Upon receiving payment in full, the client receives permission for single use.
Legend west

Landscaping / Planting Legend

South
coloured concrete

North
river pebbles (20 - 40mm, weed mat under)
2D Plant East
Symbol
Garden Mulch
Waterhousia Syzguim Lxora Liriope Dietes
Name
Floribunda Australe Coccinea "Evergreen Giant" Bicolor
'A' grade turf
Pot Size 45l 200ml 200ml 140ml 140ml

Width 3.5m 1.5-2.0m 2.0m 0.8m 1.0m paved garden edging to front / timber to rear
Height 8m 0.5-1.0m 0.5-1.0m 0.6m 0.8m
1800mm high timber fence
All plant species & quantities are indicative and subject to availability and suitability to site. Should a
particular nominated plant not be available an equilavant replacement shall be used.
1500mm high timber top
rail & posts with pool
style infill fencing
denotes batter
rock retaining wall

tiered rock retaining wall timber retaining wall


max height 1m direction of fall
L Rendered Leterbox
R B Rubbish Bins
1.8m high fence return
1m back from front building line

drainage catch basins as required

coloured concrete driveway finish

dismantle existing footpath


replace with coloured concrete
FFL RL 10.570
PAD (FGL) 9.600 approx. FFL RL 7.810
PAD RL 7.500

Pla gor
LOT 2406
374 M2

ce
Gre
gate

Mc
rock retaining wall
max height 1m

rock retaining wall 1.8m high fence & gate return


max height 1m 1m back from front building line

Area Calculations
Living Lower: 29.56 sqm
Living Upper: 119.98 sqm
Garage: 36.08 sqm
Porch: 3.98 sqm
Alfresco: 12.31 sqm
Total: 201.91 sqm

T: (07) 5602 6177 0408 701 623


We reserve the right to alter designs, colours and Please Read Carefully Client: Title: Plot Date: 6/07/2015 Drawing No: Issue: Scale: 1:200 @ A3
specifications without notice. Whilst every care has
This plan certified correct is the one referred to in the contract &
W: www.thehousedesigners.com.au been taken in the preparation of this document, the
particulars contained herein are not to be constructed specifications and I understand change hereafter may not be
xxx Landscaping Plan o
Job N : 12 of 12 Designed By: MB
A: 1 / 7 Straithaird Road Bundall QLD 4217 as any respresentation of fact. All information provided to
possible. These plans supercede all other previous plans or sketches. Design Name:
P: Po box 3282 Nerang DC QLD 4210
us is from reputable sources and no responsibility is
accepted by the vendor, it's servants or agents for any errors
xxx Drawn By: MB
Owner / s ..............................................................Date...................
or omissions. All interested parties should make their own
Outrigger 201 Working Drawings
QBCC: 1274038 enquiries to satisfy themselves in relation to all matters. Owner / s ..............................................................Date................... Checked By: MB
© The House Designers. The copyright of these floor plans are owned by The House Designers. The floor plans may not be reproduced, copied or dealt with in any manner which infringes the exclusive rights of The House Designers. Upon receiving payment in full, the client receives permission for single use.

You might also like