Product List Under SWR Fittings Standard IS 14735: 1999: Minimum

Download as pdf or txt
Download as pdf or txt
Download as pdf or txt
You are on page 1/ 2

Product list under SWR Fittings standard IS 14735 : 1999

i) Tee (87.5°) , Wye (45°) single, double (cross) or reducing with or without inspection doors
ii) Bend with or without inspection doors (87.5°, 45° and 22° )
iii) Reducer
iv) Coupler
v) Socket plug
vi) Cleansing pipe
vii) Adaptor
viii) Vent cowl
ix) Pipe clip
x) Waste trap with strainer

Size Group -1 40 to 110mm


Group -2 125 to 160mm

CIPET Ahmadabad, Jaipur, Vijayvada and Hyderabad, labs preferable BIS recognized Lab

Material : Polyvinyl Chloride and additives - Use of own Clean Rework material 10% allowed

Tests
Dimension – Wall thickness , Socket Dimensions, Chamfer , Access Openings
Dimension of Waste trap ( Nahani Trap)
Dimension of Vent Cowl
Dimension of Pipe Clip
Workmanship - Finishing
Visual appearance - Fittings Ends
Stress Relief Test - 150°C for 1Hour
Vicat Softening test - VST Shall not be less than 78 °C
Resistance to sulphuric acid test - 14 Days at 55 °C in Sulphuric acid
Titanium Dioxide content test - shall not be less than 2.5% by mass Lab test once in 6 months
Sulphated Ash Content test - Shall not be more than 10% by mass
Impact test (Drop test) - Drop freely from a height of 2m for Upto 75mm and 1 m above 75mm
Water Tightness of Joint – 0.05Mpa (0.5Kg/cm2 ) for 15 minutes

Sealing Rings As per IS 5382 having IRHD Hardness of 50 ± 5

Wall thickness at Dimension for Solvent Cement fittings Dimension for Ring seal fittings
DN Length of Neck Length
Plain Socket Mean ID at mid Mean OD Depth Mean ID at Mean OD of
bending of behind
End minimum point of Spigot minimum mid point Spigot
Neck socket bending
mm e e2 e3 D1 D2 U D1 A max B min C min D2
40 3.2 - 3.8 2.9 2.4 40.1- 40.3 40.0 - 40.3 26 40.1- 41.1 18 5 18 40.0 - 40.3
50 3.2 - 3.8 2.9 2.4 50.1 - 50.3 50.0 - 50.3 30 50.1 – 51.1 18 5 20 50.0 - 50.3
63 3.2 - 3.8 2.9 2.4 63.1 - 63.3 63.0 - 63.3 36 63.1 – 64.1 18 5 23 63.0 - 63.3
75 3.2 - 3.8 2.9 2.4 75.1 - 75.3 75.0 - 75.3 40 75.1 – 76.2 20 5 25 75.0 - 75.3
90 3.2 - 3.8 2.9 2.4 90.1 - 90.3 90.0 - 90.3 46 90.1 – 91.2 23 5 28 90.0 - 90.3
110 3.2 - 3.8 2.9 2.4 110.1 -110.4 110.0 - 110.4 48 110.1 -111.3 26 6 32 110.0 - 110.4
125 3.2 - 3.8 2.9 2.4 125.1 – 125.4 125.0 - 125.4 51 125.1 – 126.4 28 7 35 125.0 - 125.4
140 3.6 – 4.2 3.2 2.7 140.2 – 140.5 140.0 - 140.5 54 140.2 – 141.4 30 8 38 140.0 - 140.5
160 4.0 – 4.6 3.6 3.0 160.2 – 160.5 160.0 - 160.5 58 160.2 – 161.5 32 9 42 160.0 - 160.5
Dimension of vent Access
Pipe Clips
Cowl Opening
DN
in Socket Clear Dimension of waste Trap
Socket Stand off
Wall Opening Mean ID
mm Depth distance
thickness Diameter min - max
minimum Minimum
minimum minimum
40 20 1.8 40 50 40.0 - 40.4 Maximum Diameter of Rim 135mm
50 20 1.8 50 55 50.0 - 50.4 Minimum depth of bowl 80mm
63 20 1.8 54 61 63.0 - 63.4 Minimum water seal 10mm
75 22 2.0 54 67 75.0 - 75.5 Minimum Spigot length 70mm
90 22 2.0 54 75 90.0 - 90.6 OD at spigot end 75mm to 77mm
110 24 2.0 63 85 110.0 - 110.7
125 24 2.0 63 92.5 125.0 - 125.7
140 24 2.0 63 100 140.0 - 140.8
160 24 2.0 75 110 160.0 - 160.8