PRODUCT LINEUP

VRF
For LIGHT COMMERCIAL
& RESIDENTIAL,
COMMERCIAL

100
AIRSTAGE™ VRF Systems can be designed
to create an air conditioning solution to
suit most building requirements.
AIRSTAGE™ VRF Systems can be designed to effectively provide
an air conditioning solution from a large domestic residence
through to a large scale commercial building.

102 AIRSTAGE™ Solutions


110 CORE TECHNOLOGY J-Series

VRF
114 VRF Outdoor Units Lineup
116 AIRSTAGE™ J-Series OVERVIEW
126 CORE TECHNOLOGY V-Series
128 AIRSTAGE™ V-Series OVERVIEW

AIRSTAGETM J-Series
120 AIRSTAGE™ J-IIS
122 AIRSTAGE™ J-III
124 AIRSTAGE™ J-IIIL

AIRSTAGETM V-Series
130 AIRSTAGE™ VR-II
134 AIRSTAGE™ V-III

VRF INDOOR UNITS


138 VRF Indoor Units Lineup
140 NEW INDOOR UNITS
• Compact Cassette Grille Type
• Wall Mounted
142 VRF Indoor Units Specifications

FUJITSU GENERAL (Euro) GmbH participates in


the ECP programme for AIR CONDITIONERS.
Check ongoing validity of certificate:
www.eurovent-certification.com
* Models so marked are not ECC certified.

101
SOLUTIONS

For LIGHT COMMERCIAL

SMALL OFFICES
Fujitsu General provides perfect total air conditioning systems that take
into account energy saving, low noise, comfortable airflow, small room
application and centralised control for small-sized office buildings with
many small rooms.

NEW

J-IIIL
J-III J-IIIL High capacity model

AIRSTAGETM J-Series
Up to 16 HP by compact outdoor unit
Small VRF system is suitable for the buildings with many small rooms. Max. 40*
indoor units can be connected.
*Only J-IIIL 16 HP model

116 Page ~

J-IIIL

Energy saving solution suitable Compact and low noise design


for meeting rooms and business outdoor unit
discussion rooms
This compact outdoor unit doesn’t take up
When there are no people in the room, save much space even if installed in a machine
operation starts automatically to prevent room or on the rooftop. This unit secures
unnecessary power consumption by linking enough static pressure even if there are
up with a human sensor and external input/ louvres. Low noise operation is possible at
output kit. night time by a low noise mode.

102
Compact Cassette Grid Type

Centralised control of New design Grilles ideal for a


both air conditioning grid ceiling
and ventilation We have equipped a new 620 mm square design panel that is
equipment ideal for the grid ceiling found in many offices in Europe. Easy
installation and finished appearance are enhanced by these
It is possible to perform centralised control new panels.
to stop the operation of lighting and
ventilation equipment in addition to air 140 Page
conditioners. This is useful in energy saving
management over the whole building.
NEW
620 mm
166 Page

Compact Cassette
VRF Grid Type
indoor units

Facilities
Lighting Ventilation Energy Recovery 1.1 kW personal
Ventilator
air conditioning
Various range of low capacity
1.1 kW indoor units to suit small
rooms or spaces.

143 Page ~

System Controller Lite

103
SOLUTIONS

For LIGHT COMMERCIAL

SCHOOL
Fujitsu General provides the optimal number of connected indoor units for
mid sized educational institutions. The degree of freedom of the installation
location selection is improved with a compact design that minimises the
installation area. Even one outdoor unit can cover the entire school building.

LAN

PC

Touch Panel Controller UTY-DTGYZ1


Wireless Fixed IP, IP forwarding
and open Port required
LAN

INTERNET
New centralised remote Router TTablet
bl t PC
controller with improved Smartphone
iOS, Android and/or Windows
operability Control and
Temperature management of each classroom and one
week operation control management/settings are
monitoring
supported easily. This controller makes energy saving The same management as with the
management possible with upper/lower temperature main unit is possible even if you are at
limit settings and operation prohibited settings. your desk. Non-administrators can also
operate the air conditioners with a PC,
164 Page Smartphone or tablet.

104
Cassette Circular Flow

Comfortable room air conditioning with


comfortable temperature contrast
Circular Airflow Cassette
blows out in all directions
without temperature
Bulkhead Duct unevenness

Individual airflow direction control to prevent people from


being exposed to draughts

NEW Energy Recovery Ventilator

196 Page
Energy saving operation when there
are no people by linking up with
human sensor

Various indoor units


We have a lineup of indoor units that can also support 3.2 m
complex applications – from normal classrooms to special
classrooms and auditoriums. Air conditioners can also be 8.8 m
Human sensor
added easily.
(Option)

105
SOLUTIONS

For LIGHT COMMERCIAL

HOTELS
Fujitsu General provides perfect total air conditioning systems that take
into account comfort, energy saving, external appearance, safety and
easy installation for small low-rise hotels.

NEW

J-IIIL
High capacity model
J-III J-IIIL

AIRSTAGETM J-Series
Appearance-
oriented compact
outdoor unit
Due to the lowest and most compact
design in the industry, the appearance
of the hotel is not affected even when
Ventilation of
installed on the building’s roof the whole hotel
116 Page ~ supported
Outdoor air processing is essential in
hotel spaces with a high degree of
airtightness. The DX-Kit can link up with
AHU’s to ensure sufficient ventilation.
This system can be expanded.

Large space air


conditioning in the
reception and lobby
Ultra-large duct type single split system
suitable for large spaces with high
ceilings EEV unit Control unit

062 Page 204 Page


106
Guest room air conditioning
with excellent comfort, energy
saving and easy installation

Space saving
Bulkhead duct type with
198 mm height and 450 mm
depth. This can be installed Bulkhead Duct
in narrow ceiling space easily.
144 Page

Card key switch available Comfortable airflow that


(By others) switches up and down air
Using the card key prevents directions
you from forgetting to switch The Auto Louvre Grille Kit
off the air conditioner. achieves comfortable airflow
by adjusting the air direction.

Use of an external Auto Louvre Grille Kit


connect kit and switch
(By others)

177 Page 184 Page

System controller

Centralised control
of air conditioning
in shared spaces Simple Remote Controller with
sophisticated design
Air conditioning in shared spaces such
as lobbies and hallways is controlled Suitable for hotels or offices as it is easily operated with no
centrally. Temperature and operating complex functions.
conditions can be managed without the Large LCD screen & simple operation buttons White coloured
adjustment by guests. backlight on monitor enable easy operation in dark.

166 Page 159 Page


107
SOLUTIONS

For COMMERCIAL

LARGE BUILDING
Fujitsu General provides modular type VRF systems that seek high
efficiency, comfort, design freedom, easy installation and reliability for
large buildings.

Abundant lineup suitable


to match the operating
environment
VRF series lineup to meet various needs such as energy saving-
orientated models and models compatible with a high outdoor
air temperature of 52°C
Individual air conditioning system for
large buildings
Capacities can be expanded up to
simultaneous cooling and heating with
maximum 48HP. Large individual air
conditioning is supported.

Smart and cutting edge design. Extensive lineup from 8 HP to


48 HP in 2 HP increment. Connectable indoor unit capacity ratio
up to 150%
8 HP - 48 HP 34 Models 8 HP - 54 HP 39 Models
• Space saving combination: 8 HP to 48 HP/21 models • Space saving combination: 8 HP to 54 HP/24 models
• Energy efficiency combination: 16 HP to 44 HP/13 models • Energy efficiency combination: 16 HP to 46 HP/ 15 models

128 Page ~ 128 Page ~


108
Centralised control
Not only indoor units in the building but also facilities such as
ventilation can be controlled easily by anyone.

System Controller
(UTY-APGXZ1)
System Controller Lite
(UTY-ALGXZ1 & UTY-PLGXX2)

166 Page

Remote/
VRF Monitoring side
indoor units

INTERNET

Facilities
Lighting Ventilation Energy Recovery
Ventilator

Router
Smartphone

Link up with a variety of BMS


Centralised control including facilities and equipment in
addition to air conditioning is possible by linking up with
MODBUS, BACnet, KNX and other various interfaces.

Installation
Example

High system Rapid service support


flexibility The air conditioning of the entire building can be monitored
remotely with Web Monitoring Tool and System Controller.
Flexible installation on each floor and Rapid response for emergency is possible by a self-diagnosis in
installation of diverse indoor units are advance in cooperation with a management company.
possible through the industry’s top class
high static pressure, long piping design
and connection capacity. Remote Monitoring
Internet Web
or Monitoring
Public Telephone Tool
Line UTY-AMGXZ1

82 Pa
*: For V-III series.
Software

VR-II series are


80 Pa

109
PRODUCT LINEUP: VRF

CORE TECHNOLOGY
for AIRSTAGETM J-Series

High Energy Efficiency


Efficiency is improved 7%UP!
significantly by using DC twin 8%UP! Wide operating range
rotary compressor, inverter 5 Installation in extreme temperature
technology, and large heat 3.95
4.23 conditions is possible due to an increase in
4 3.71
exchanger 3.45 operational range.
3

2
AIRSTAGE™ J-IIIL series AIRSTAGE™ J-III &
1 Heat Pump type J-IIS series
Heat Pump type
0
J-II J-III J-II J-III Cooling Cooling
series series series series
46°C 46°C

Heating Heating

21°C 21°C

-5°C*1 -5°C

-20°C -20°C

Heat Pump (6 HP)


*1: Only when all indoor units are 5.6 kW or more in the
system, the operation range is -15 to 46ºC.

High capacity connection

Connectable indoor unit


Series Connectable indoor unit number
capacity range
*2: Conditions of maximum
AIRSTAGE™ J-IIIL series
connectable indoor unit
14/16 HP 50% to 150%*2 up to 40
Heat Pump type capacity ratio is as the chart
above.
AIRSTAGE™ J-IIIL series
*3: Only 4 HP is 46%
8/10/12 HP 50% to 150%*2 up to 30
Heat Pump type

AIRSTAGE™ J-III series


Heat Pump type 50% to 150%*2 up to 13
AIRSTAGE™ J-IIS series
Heat Pump type 50%*3 to 130%*2 up to 8

Designed for
low refrigerant charge
Installing
Optimal design of indoor unit and outdoor in
unit reduces the refrigerant volume and Small Room
special support is not required even when
installing in a small room of about 15 m2.

110
Design Flexibility
AIRSTAGE TM J-Series Compact Outdoor Unit
Top class Compact design
Compact outdoor unit can be attained at
the top class in the industry by optimal
NEW
airflow structure design. (Up to 16 HP)

J-IIIL
J-IIS J-III J-IIIL High capacity model

VRF
AIRSTAGE TM J-IIIL series
Long piping design
Piping design suitable for long, narrow
office buildings with a difference in height
and low-rise shops with depth
(AIRSTAGE TM J-IIIL series)

Height difference max. Piping length from first max.


between indoor and separation tube to the
indoor units 50m farthest indoor unit 90m

More Comfort
Precision refrigerant flow control Auto changeover Quiet priority setting

Precise and smooth refrigerant flow control is achieved by using a DC Air


conditioning
Inverter control in conjunction with individual indoor unit electronic load factor Heat load
expansion valve control. This allows high precision comfortable
temperature control of ±0.5°C. Capacity
100% down

Operating 58 dB
Auto changeover function sound
0
time
At Auto setting, the cooling/heating mode is automatically Quiet priority low noise mode
switched according to the set temperature and room
Capacity priority setting
temperature.
Air
conditioning
load factor Heat load
Quiet operation
100% Alternated
Two low noise modes can be selected automatically by quiet Capacity
automatically
priority setting and capacity priority setting depending on 0
the indoor environment and outside temperature load. This Operating 58 dB
feature can be controlled via outdoor unit external input sound
0
and/or system controller. Reset automatically time
Capacity priority low noise mode

111
PRODUCT LINEUP: VRF-CORE
VRF-AIRSTAGE
TECHNOLOGY
J-Series for AIRSTAGE J-Series & V-Series
TM TM

High Reliability Liquid flow back protection


Completely from
vaporised refrigerant Evaporator

Liquid flow back protection


By adopting a large sized accumulator, not completely
vapourised refrigerant stays inside of the accumulator to Liquid refrigerant
ensure no liquid refrigerant is being fed into the compressor. (Stays inside of
accumulator)

Compressor Large sized


Accumulator

Backup operation*1 Advanced refrigerant control*1


If one compressor fails, backup Innovative compressor control logic has been introduced in order
operation will be performed by the to balance the refrigerant mass flow rate of each outdoor unit by
remaining compressors.*2 controlling the inverter speed.

Balance operation condition Unbalanced operation condition

ON ON ON ON ON OFF

DC DC DC DC DC DC
1 2 3 1 2 3

Master Slave 1 Slave 2 Load level Master Slave 1 Slave 2

*1: Not available for AIRSTAGE™ J-III and J-IIS series *2: Note: Backup operation may not be possible depending on the fault condition.

Easy Installation
Up to maximum length

Simple wiring work or 3,600 m


Installation of the wiring systems is made easier as the
communication wiring can be installed continuously
Note: Serial connection can’t use the
between the indoor, outdoor and RB units. automatic address setting in a multiple
Parallel connection Serial connection refrigerant system.

Automatic address setting Automatic address setting is


Addresses are automatically
performed at outdoor unit
The address of the indoor unit, RB unit and distributed from outdoor unit.
signal amplifier through the automatic
function setting on the outdoor unit PCB. 1 Signal Amplifier

RB unit 3 7 1 0

3 7 1 0
Press the push button
switch of outdoor unit.
2 4 5 6
Manual address setting from
indoor unit and remote controller is
also possible. 2 4 5 6
112
SPLIT
Easy Service & Maintenance
7-segment LED
Design for easy maintenance

MULTI SPLIT
Easy to read 7-segment LED :
Confirm detailed operational and error status without using any
specific equipment.
• Operation mode status
• Discharge temperature/Pressure status
• Compressor operation indication
• Address/type/number of outdoor unit
Error and quantity
Movable PCB panel: display
Easier for maintenance work behind the PCB
Error code

Abnormal indoor
unit address

VRF
• Error status can be checked easily by
outdoor unit display

Error status can be checked easily via the indoor unit wired controller
An error code is displayed on a liquid crystal screen.

Wired Remote Controller Simple Remote Controller Wired Remote Controller (Touch panel)
System number Error status / Error history
001: Controller Remote controller address

OPTIONAL PARTS
002: Indoor unit Error code
Error code

Unit number

Error diagnosis by Service Tool Remote monitoring


VENTILATION

Connection to Service Tool The Web Monitoring system allows you to view system operation
• Detail operation status and recent error history can be anytime over the internet, ensuring issue free operation.
checked and analysed by using the Service Tool. The operating VRF network system in the building can be monitored
• Last 5 min. operation memory can be also be recorded. real time over the Internet.

Outdoor unit Monitoring Side

Transmission line VRF Network System Side


Service
Outdoor unit
Tool
UTY-ASGXZ1 Transmission
Software line

RB unit Internet
or
USB adaptor Public Telephone
(Locally purchased) USB adaptor
Line
TRAINING

(Locally purchased)
Indoor unit
Web
Monitoring Tool

Indoor unit

113
PRODUCT LINEUP: VRF

VRF Outdoor Units Lineup


Capacity (kW) 12.1 14.0 15.1-15.5 22.4 28.0 33.5 40.0 45.0 50.4 55.9 61.5 67.0 73.5
HP 4 5 6 8 10 12 14 16 18 20 22 24 26

J-IIS Series
Page 120

AJY040 AJY045 AJY054


LCLAH LCLAH LCLAH

J-III Series
Page 122
AJY040 AJY040 AJY054
LBLAH, LBLAH, LBLAH,
AJY040 AJY040 AJY054
LELAH LELAH LELAH

NEW NEW

J-IIIL Series
Page 124~

AJY072 AJY090 AJY108 AJY126 AJY144


LELAH LELAH LELAH LELAH LELAH

Space Saving

Page 130~
VR-II Series Heat Recovery

AJYA72 AJYA90 AJY108 AJY126 AJY144 AJY162 AJY180 AJY198 AJY216 AJY234
Set Model GALH GALH GALH GALH GALH GALH GALH GALH GALH GALH

Energy

Efficiency

Page 130~

AJY144 AJY198 AJY216 AJY234


Set Model GALHH GALHH GALHH GALHH

Space Saving

Page 134~
V-III Series Heat Pump

AJY072 AJY090 AJY108 AJY126 AJY144 AJY162 AJY180 AJY198 AJY216 AJY234
Set Model LALBH LALBH LALBH LALBH LALBH LALBH LALBH LALBH LALBH LALBH

Energy

Efficiency

Page 134~

AJY144 AJY162 AJY180 AJY216 AJY234


Set Model LALBHH LALBHH LALBHH LALBHH LALBHH

114
78.5 85.0 90.0 95.0 100.5 107.0 112.0 118.5 123.5 130.0 135.0 140.0 145.0 150.0
28 30 32 34 36 38 40 42 44 46 48 50 52 54

VRF
AJY252 AJY270 AJY288 AJY306 AJY324 AJY342 AJY360 AJY378 AJY396 AJY414 AJY432
GALH GALH GALH GALH GALH GALH GALH GALH GALH GALH GALH

AJY252 AJY270 AJY288 AJY306 AJY324 AJY342 AJY360 AJY378 AJY396


GALHH GALHH GALHH GALHH GALHH GALHH GALHH GALHH GALHH

AJY252 AJY270 AJY288 AJY306 AJY324 AJY342 AJY360 AJY378 AJY396 AJY414 AJY432 AJY450 AJY468 AJY486
LALBH LALBH LALBH LALBH LALBH LALBH LALBH LALBH LALBH LALBH LALBH LALBH LALBH LALBH

AJY252 AJY270 AJY288 AJY306 AJY324 AJY342 AJY360 AJY378 AJY396 AJY414
LALBHH LALBHH LALBHH LALBHH LALBHH LALBHH LALBHH LALBHH LALBHH LALBHH

115
PRODUCT LINEUP: VRF

AIRSTAGE J-Series
TM

OVERVIEW
Fujitsu General provides air conditioning systems for a wide range of applications
from small office buildings and hotels to large stores, houses.

J-IIIL is an outdoor unit with a slim design offering a high degree of freedom of installation that is
recommended for mid-size office buildings and hotels. Furthermore, you can connect up to 40* indoor units
with newly added 14/16 HP model. 14/16 HP model is also ideal for hospitals and educational facilities with
many rooms. (*: 16 HP model)

Slim Outdoor Unit


Although this is a 14/16 HP model that can handle slightly
larger properties, it has a slim depth of 480 mm. This model
can be introduced and installed even in limited spaces.

Small room application


Up to 30-40 indoor units can be connected by the optimum
heat exchanger structure. Available to various small rooms.

Top Class Low Operating Sound


Top class low sound operation has been achieved. This allows
installation of the units in locations without any special sound
attenuation work.
NEW

118 Page
14/16 HP models 8-12 HP models

116
VRF
J-III improves the system with up to 13 indoor units. J-IIS has a compact design with a height of 998 mm
This model is suitable for small buildings and light that does not obstruct visibility even when installed
commercial applications. near waist-high windows. This model is also ideal for
large houses, retail stores and other properties.

High Energy Efficiency Space saving and low sound level design
Heat pump inverter control is used to achieve an Economical individual air conditioning is achieved
efficient cooling and heating operation in any indoor by ALL-DC technology, large capacity DC twin rotary
unit combination. compressor, and 3-row heat exchanger though the size
is compact.
Flexible systems for small- and
medium-size buildings air conditioning Flexible systems for homes, shops,
Space saving design and long piping design allow for small-size buildings air conditioning
flexible installation on the roofs or balconies of small Due to compact size design and flexible piping design,
and medium-size buildings. J-IIS series can be installed easily at the place where
Multiple indoor units of various capacities and types the installation space is limited such as homes, shops,
can be connected. and small offices. Multiple indoor units of various
capacities and types can be connected.

122 Page 120 Page

117
PRODUCT LINEUP: VRF-AIRSTAGE J-Series TM

NEW 14/16 HP models & 8/10/12 HP models

Fujitsu General provides perfect total air


conditioning systems that take into account
energy saving, low noise, comfortable
airflow, small room application and
centralised control for small-sized office
buildings with many small rooms.

Image: 8/10/12 HP models

118
SPLIT
Slim & Compact Design Height difference

-262 mm
Compared with current 8 HP model

NEW

8/10/12 HP model
14/16 HP model

1,690 mm

1,428 mm

MULTI SPLIT
765 mm
Current model
AIRSTAGETM V-Series
outdoor unit
14/16 HP model
480 mm Current model
AIRSTAGETM V-Series
outdoor unit
8/10 HP model
Depth difference Space area Space area

-285 mm
J-IIIL all models
-45% !
Compared with
-26% !
Compared with
Compared with current models current 14/16 HP model current 8/10 HP model

VRF
Inhouse installation

AIRSTAGE TM J-Series outdoor unit AIRSTAGE TM V-Series outdoor unit

OPTIONAL PARTS
Low noise in consideration for the nearby residents
This model is front blow type and about 1000 mm wide, so flexible installation is possible
even at narrow inhouse space.

Installation at building side

AIRSTAGE TM J-Series outdoor unit AIRSTAGE TM V-Series outdoor unit


VENTILATION

Space saving
Due to compact and thin model, direct ground installation or wall mounted installation is
possible even at narrow off-street.

Installation at the back of the building


TRAINING

AIRSTAGE TM J-Series outdoor unit AIRSTAGE TM V-Series outdoor unit


Flexible installation
This model is front blow type and slim & low body, so installation space is compact. Building
windows are not blocked and space saving multiple units installation is possible.

119
PRODUCT LINEUP: VRF-AIRSTAGE J-Series TM

Heat Pump
for Small Capacity Type

Long piping length


Total pipe length Height difference
Our advanced refrigerant control technology between outdoor and

80 m
indoor units
allows us to achieve a total refrigerant
piping length of 80 m. This opens up new Max. 30 m max.
possibilities in system design.

Actual piping length

50 m max.

Piping length from first Height difference


separation tube to the between indoor and
furthest indoor unit indoor units

40 m max. 15 m max.

Non-stop oil recovery operation Easier Installation


A comfortable room condition is maintained during oil Connection check function : Possible to confirm whether wiring
recovery mode because the product continues to operate connection and address setting are correct by a quick check run
without stopping the cooling or heating operation. function.

Previous model J-IIS series

Operation stopped
Non-stop oil recovery operation
at oil recovery

ON ON • Display connected indoor unit numbers


• Duplicated indoor unit addresses can be displayed
OFF
Time Time

120
4,5,6HP : AJY040LCLAH / AJY045LCLAH / AJY054LCLAH

SPLIT
Specifications

MULTI SPLIT
Rating Capacity range HP 4 5 6
Model name AJY040LCLAH AJY045LCLAH AJY054LCLAH
Maximum Connectable Indoor Unit 7 8 8

Power source Single-phase, ~230V, 50Hz


Cooling 12.1 14.0 15.1
Capacity kW
Heating 13.6 16.0 16.5
Cooling 3.44 4.43 5.03
Input power kW
Heating 3.09 3.93 4.11
EER/SEER (LOT21) Cooling W/W 3.52 / 5.81 3.16 / 5.39 3.00 / 5.15
COP/SCOP (LOT21) Heating W/W 4.40 / 4.38 4.07 / 3.90 4.01 / 3.82
$LUÁRZUDWH m3/h 4,040 4,200 4,200
Sound pressure level / Cooling 51 / 67 53 / 69 54 / 70
dB(A)
Power level Heating 54 / 68 55 / 69 56 / 70
Minimum Recommended MCB AMP 32 32 32
Height 998 998 998
Net Dimensions Width mm 970 970 970

VRF
Depth 370 370 370
Weight kg 86 86 87
Type R410A R410A R410A
Refrigerant
Charge kg 4.0 4.0 4.0
Connection pipe Liquid 3/8 3/8 3/8
Inch
diameter Gas 5/8 5/8 5/8
Total pipe length 80 80 80
m
Max. height difference 30 30 30
Cooling -5 to 46 -5 to 46 -5 to 46
Operation range Ý&
Heating -20 to 21 -20 to 21 -20 to 21

OPTIONAL PARTS
Note : Specifications are based on the following conditions.
Cooling : Indoor temperature of 27°CDB / 19°CWB, and outdoor temperature of 35°CDB / 24°CWB.
Heating : Indoor temperature of 20°CDB / (15°CWB), and outdoor temperature of 7°CDB / 6°CWB.
Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m.
The protective function may work when using it outside the operation range.

Dimensions
(Unit : mm)

Top view
VENTILATION

Front view
Rear view
Side view
TRAINING

Bottom view Detail A

121
PRODUCT LINEUP: VRF-AIRSTAGE J-Series TM

Heat Pump
for Small Capacity Type

Long Piping Length


Total pipe length
Our advanced refrigerant control technology allows us to
achieve a total refrigerant piping length of 180 m. This opens
up new possibilities in system design.
Max. 180 m
Height difference
between outdoor and
indoor units

50 m max.
For the outdoor unit
installed below the
indoor units: 40 m max.

Height difference Piping length from first


between indoor and separation tube to the Actual piping length
indoor units furthest indoor unit

15 m max. 40 m max. 120 m max.

Non-stop oil recovery operation Easier Installation


A comfortable room condition is maintained during oil Connection check function : Possible to confirm whether wiring
recovery mode because the product continues to operate connection and address setting are correct by a quick check run
without stopping the cooling or heating operation. function.

Previous model J-III series

Operation stopped • Display connected indoor unit


Non-stop oil recovery operation
at oil recovery numbers
ON ON • Duplicated indoor unit addresses
can be displayed
OFF
Time Time

122
4,5,6HP : AJY040LBLAH / AJY045LBLAH / AJY054LBLAH
AJY040LELAH [3phase] / AJY045LELAH [3phase] / AJY054LELAH [3phase]

SPLIT
MULTI SPLIT
Specifications
Rating Capacity range HP 4 5 6 4 5 6
Model name AJY040LBLAH AJY045LBLAH AJY054LBLAH AJY040LELAH AJY045LELAH AJY054LELAH
Maximum Connectable Indoor Unit 1-9 1-10 1-13 1-9 1-10 1-13

Power source Single-phase, ~230V, 50Hz 3-phase, ~400V, 50Hz


Cooling 12.1 14.0 15.5 12.1 14.0 15.5
Capacity kW
Heating 13.6 16.0 18.0 13.6 16.0 18.0
Cooling 2.90 3.57 4.18 2.79 3.46 3.99
Input power kW
Heating 2.80 3.55 4.26 2.71 3.40 4.08
EER/SEER (LOT21) Cooling W/W 4.17 / 5.99 3.92 / 5.85 3.71 / 5.78 4.33 / 6.15 4.05 / 5.98 3.88 / 5.97
COP/SCOP (LOT21) Heating W/W 4.86 / 3.92 4.51 / 3.85 4.23 / 3.78 5.01 / 4.10 4.70 / 4.04 4.41 / 4.00
$LUÁRZUDWH m3/h 6,200 6,400 6,900 6,200 6,400 6,900
Sound pressure level / Cooling 50 / 66 51 / 67 53 / 69 50 / 66 51 / 67 53 / 69
dB(A)
Power level Heating 52 / 68 53 / 69 55 / 71 52 / 68 53 / 69 55 / 71
Minimum Recommended MCB AMP 32 32 32 16 16 16

VRF
Height 1,334 1,334 1,334 1,334 1,334 1,334
Net Dimensions Width mm 970 970 970 970 970 970
Depth 370 370 370 370 370 370
Weight kg 117 117 119 119 119 119
Type R410A R410A R410A R410A R410A R410A
Refrigerant
Charge kg 4.8 5.3 5.3 4.8 5.3 5.3
Connection pipe Liquid 3/8 3/8 3/8 3/8 3/8 3/8
Inch
diameter Gas 5/8 5/8 3/4 5/8 5/8 3/4
Total pipe length 180 180 180 180 180 180
m
Max. height difference 50/40 (Outdoor unit: Upper/Lower) 50/40 (Outdoor unit: Upper/Lower)
Cooling -5 to 46 -5 to 46 -5 to 46 -5 to 46 -5 to 46 -5 to 46
Operation range Ý&
Heating -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21

OPTIONAL PARTS
Note: Specifications are based on the following conditions.
Cooling: Indoor temperature of 27°CDB/19°CWB, and outdoor temperature of 35°CDB/24°CWB.
Heating: Indoor temperature of 20°CDB/(15°CWB), and outdoor temperature of 7°CDB/6°CWB.
Pipe length: 7.5 m; Height difference between outdoor unit and indoor unit: 0 m.
The protective function may work when using it outside the operation range.

Dimensions
(Unit : mm)

166 650 154


43(Liquid)

51(Gas)
(410)
370

Top view
40

36
32

VENTILATION

970 32 370 12

Terminal blocks (Transmission)

Terminal blocks (Power)


1334

1000
907

3-Way valve (Liquid)

3-Way valve (Gas)


111

70
(Liquid valve)

le port)
(Gas valve)

Ø28 (Cab
Front view
297
279

120
21

25
95

155

142
131
87

Rear view
Ø28 (Cable port) Ø28 (Cable port)
50

50

50

Ø28 (Cable port) 89 Pipe port 21 55 Ø28 (Cable port) 21 65 Ø28 (Cable port)
Pipe port Pipe port

A
65 15
Side view
227
305

14
341

TRAINING
50

50 Pipe & cable port


438
622

Bottom view

123
PRODUCT LINEUP: VRF-AIRSTAGE J-Series TM

NEW
Heat Pump
for Small Capacity Type

Long Piping Length


Total pipe length
Our advanced refrigerant control technology allows us to
achieve a total refrigerant piping length of 400 m. This opens
up new possibilities in system design.
Max. 400 m
Height difference
between outdoor and
indoor units
Up to 40 units* can be connected
50 m max.
The combination of the smallest but adequate capacity indoor For the outdoor unit
unit and a new outdoor unit with the optimum efficiency heat installed below the
indoor units: 40 m max.
exchanger achieves the industry’s top class connection of 40
units. *: 16 HP model.

Piping length from first Height difference


Actual piping length separation tube to the between indoor and
furthest indoor unit indoor units
120 m max. 90 m max. 50 m* max.
*: Only when new indoor
units and J-IIIL series are
combined

High Static Pressure Top Class Low Operating Sound


External static pressure is available up to 60Pa for 14/16HP. Top class low operating sound is realised. Highly suited to densely
(20Pa for 8/10HP, 30Pa for 12HP) populated areas thanks to their low operating sound.

Sound Power Level


77 dB(A)
66 dB(A) -11 dB(A)
60Pa

J-IIIL (8 HP) Current model (8 HP)

124
8,10,12HP: AJY072LELAH / AJY090LELAH / AJY108LELAH
14,16HP: AJY126LELAH / AJY144LELAH
NEW

SPLIT
MULTI SPLIT
8, 10, 12 HP 14, 16 HP

Specifications
Rating Capacity range HP 8 10 12 14 16
Model name AJY072LELAH AJY090LELAH AJY108LELAH AJY126LELAH AJY144LELAH
Maximum Connectable Indoor Unit 1-20 1-25 1-30 1-36 1-40

Power source 3 phase, ~400V, 50Hz


Cooling 22.4 28.0 33.5 40.0 45.0
Capacity Nominal Heating kW 22.4 28.0 33.5 40.0 45.0
Max Heating 25.0 31.5 37.5 45.0 50.0
Cooling 6.30 8.59 10.42 12.12 14.96
Input power Nominal Heating kW 4.65 6.61 8.18 9.71 11.81
Max Heating 5.45 8.29 10.25 11.82 14.29
EER/SEER (LOT21) Cooling 3.56/6.72 3.26/6.48 3.22/6.72 3.30/6.33 3.01/6.16
Nominal Heating W/W 4.82 4.24 4.10 4.12 3.81
COP/SCOP (LOT21)
Max Heating 4.56/3.86 3.80/3.59 3.66/3.58 3.81/3.52 3.50/3.51

VRF
$LUÁRZUDWH m3/h 8,400 9,000 11,000 13,000 14,000
Sound pressure level / Cooling 52/66 54/69 59/73 62/75 64/77
dB(A)
Power level Heating 54/- 57/- 61/- 63/- 65/-
Minimum Recommended MCB AMP 20 20 25 40 40
Height 1,428 1,428 1,428 1,638 1,638
Net Dimensions Width mm 1,080 1,080 1,080 1,080 1,080
Depth 480 480 480 480 480
Weight kg 170 177 178 210 210
Type R410A R410A R410A R410A R410A
Refrigerant
Charge kg 7.0 7.5 7.5 11.0 11.0
Connection pipe Liquid 3/8 3/8 1/2 1/2 1/2
Inch
diameter Gas 3/4 7/8 1 1/8 1 1/8 1 1/8
Total pipe length 400 400 400 400 400
m

OPTIONAL PARTS
Max. height difference 50/40 (Outdoor unit: Upper/Lower)
Cooling -5 to 46* -5 to 46* -5 to 46* -5 to 46* -5 to 46*
Operation range Ý&
Heating -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21

Note: Specifications are based on the following conditions.


Cooling: Indoor temperature of 27°CDB / 19°CWB, and outdoor temperature of 35°CDB / 24°CWB.
Heating: Indoor temperature of 20°CDB / (15°CWB), and outdoor temperature of 7°CDB / 6°CWB.
Pipe length: 7.5 m; Height difference between outdoor unit and indoor unit: 0 m.
* The cooling operation range of -15 to 46°C is allowed only when all of the indoor units connected to the system are higher than capacity of 5.6kW.
Dimensions
(Unit : mm)
196 688 196

8, 10, 12 HP 196 688 196 14, 16 HP


(515.5)
40.5
(515.5)

VENTILATION
40.5

Top view

Top view 39 1080 40 480


1080 40 480 12

Terminal blocks (Power)


Terminal blocks (Transmission)
1638
1428

1102
1017
23.5

TRAINING

Front view Side view Front view Side view


447

479
Bottom view Bottom view
125
PRODUCT LINEUP: VRF-CORE
VRF-AIRSTAGE
TECHNOLOGY
J-Series for AIRSTAGE J-Series & V-Series TM TM

CORE TECHNOLOGY
for AIRSTAGETM V-Series

High Energy Efficiency


Efficiency is improved significantly by using DC twin rotary
compressor, inverter technology, and large heat exchanger
Wide operating range
Installation in extreme temperature
31%UP! conditions is possible due to an increase in
35%UP! 27%UP! 16%UP! operational range.
4.84
4.31 4.3
3.7
3.94 3.71 AIRSTAGE™ VR-II series AIRSTAGE™ V-III series
3.2 Heat Recovery Heat Pump
3.1
Modular type Modular type

Cooling Cooling

46°C 46°C
Cooling &

Heating Heating Heating

V V-III V V-III S VR-II S VR-II EER COP 21°C 21°C 21°C


series series series series series series series series

-10°C -10°C
-15°C*1
-20°C -20°C

*1:Note: Wen a multiple outdoor unit connection is used,


operating range is from -5ºC. to 46ºC. in coolin.

Heat Pump (8 HP) Heat Recovery (10 HP)

High capacity connection


*2: Conditions of maximum
Connectable indoor unit connectable indoor unit
Series Connectable indoor unit number
capacity range capacity ratio is as the chart
above.
AIRSTAGE™ VR-II series
NEW Heat Recovery Modular type 50% to 150%*2 up to 64 *3: Max. capacities in the
combinations including the
AIRSTAGE™ V-III series 18 HP outdoor unit fall below
Heat Pump Modular type 50% to 150%*3 up to 64
150%.

Various optional parts


• Intake fresh air with our Fresh Air Intake kit
Also
• Comfortable temperature control with a corresponds
remote sensor to
ventilation
• Operation by linking up to ventilation
equipment and air handling unit with the
DX-Kit

Fresh Air Intake kit EEV unit Control unit

126
SPLIT
Energy Saving Function
Economy operation Room temperature set point limitation

MULTI SPLIT
Set Temp.
Economy operation can be set by remote controller. The
Down
temperature setting is offset automatically over a certain Heating Set Temperature Down
Down
period of time. MAX. -4°C Down
Economy operation
Control Temperature
Economy operation
Room temperature set point limitation
The minimum and maximum temperature ranges can Set Temp.
be limited, which provide further energy saving while Economy operation Economy operation
maintaining the comfort of the occupants. Control Temperature

MAX. +2°C Up
Cooling Set Temperature Up
Auto-off timer
• The indoor unit automatically is turned off when it reaches
the preset operating time frame. Auto-off timer

VRF
• The time frame of the "Auto off timer" can be flexibly
scheduled.
Set interval time (17:00–24:00)

ON OFF ON Auto OFF ON Auto OFF


Capacity save operation 1 hour 1 hour
Operation capacity can be set in 5 steps for rated capability. The
power consumption at peak is cut down and the maximum load is Normal Time Over Time

suppressed. 8 17 24

OPTIONAL PARTS
Design Flexibility
Overall piping length AIRSTAGE™ VR-II series & V-III series
Max. 1,000 m
World’s top class overall piping length of Height difference between
1,000 m allows for application in a wide outdoor and indoor units

variety of buildings.
Max. 50 m
For the outdoor unit installed below
the indoor units: 40 m max.
VENTILATION

Actual pipe length

Max. 165 m

Pipe length from first Height difference between


separation tube to the indoor and indoor units
farthest indoor unit
Max. 15 m
Max. 90 m*1*2
*1: V-III series. The limitation on
the pipe length between the
TRAINING

farthest IU and the nearest IU


originated from the first
separation tube must be 60 m
or less.

*2: VR-II series is max. 60 m.

127
PRODUCT LINEUP: VRF

AIRSTAGE V-Series
TM

OVERVIEW
AIRSTAGE™ V-Series Systems can be designed to effectively provide an air conditioning solution from a large
domestic residence through to a large scale commercial building.

Smart and cutting edge design. Extensive lineup Smart and cutting edge design. Extensive lineup
from 8 HP to 48 HP in 2 HP increment. Connectable from 8 HP to 54 HP in 2 HP increment. Connectable
indoor unit capacity ratio up to 150% indoor unit capacity ratio up to 150%

Simultaneous cooling and Excellent energy saving


heating operation using 1 refrigerant system Heat pump inverter type realises the highly energy
Cooling and heating can be freely selected for saving air conditioning for individual cooling and
each indoor unit to provide simultaneous cooling heating operation by all inverter technology for
and heating in the rooms with large temperature seasonal efficiency.
differences, etc.
High design flexibility for various
Annual cooling operation building’s air conditioning
Use annual cooling operation for the rooms and other High design flexibly meets the various needs of
spaces that require constant temperature control high-rise building air conditioning such as outdoor
throughout the year. unit roof top concentrated installation and each floor
installation by large capacity combination, sufficient
Handles changes in the temperature difference connection capacity, and high static pressure design.
The operation mode can be freely changed when there
are large temperature differences during the day, such Easy installation and maintenance
as between seasons. The flexible communication method and piping
connections make installation and maintenance easy
even for large systems.

130 Page 134 Page


128
VRF
1 Powerful large propeller fan
By using CFD*1 technology, a newly designed
fan achieves high performance and low noise
Energy saving technology that operation.
*1. CFD = Computational Fluid Dynamics
boosted operation efficiency
2 3 phase DC fan motor
Efficiency is substantially improved by high
1
efficient motor with sophisticated driver control. In
2 addition, low noise is achieved by DC fan motor.

3 Sine-wave DC inverter control


High efficiency is achieved by adoption of reduced
3
switching loss IPM.

4 4 4-face heat exchanger


Heat exchange efficiency is significantly improved
by the introduction of a new 4-face heat
exchanger that increases effective surface area.
5
5 Subcool heat exchanger
6
High Heat Exchange efficiency is achieved by
using an internal projection shape double pipe
construction.
7

6 High efficient and


large capacity DC inverter compressor
Large capacity high efficient DC twin rotary
compressor with excellent intermediate capability.

7 Front intake port


(Corner cut air inlet structure)
In multiple outdoor unit installations, the unique
front intake design improves airflow into the Heat
Exchanger.

129
PRODUCT LINEUP: VRF-AIRSTAGE V-Series TM

Heat Recovery
Modular Type

High Operating Energy Efficiency Heat exchanger


High pressure liquid
Our Heat recovery systems achieve high operating
Low pressure gas
energy efficiency by drawing heat from the room 4 way valve
to be cooled and transferring it as energy for High pressure gas
rooms that are to be heated.
Compressor

Outdoor unit

RB unit

Heat
exchanger

Indoor unit

EEV
Cooling Heating

Space saving combination


(COP) 5
4.39 4.30 4.34 4.30
4.13 4.07 4.05
3.90 3.92 3.90 3.91 4.01 3.92 4.01 3.90 4.00 3.91 4.00 3.91 3.98 3.92
4

2
8 10 12 14 16 18 20 22 24* 26 28 30 32 34 36 38 40 42 44 46 48 (HP)

Energy efficiency combination


(COP) 5
4.39 4.39 4.35 4.32 4.30
4.22 4.24 4.23 4.18 4.17
4.08 4.13 4.05
4 For 24HP Combination
Space saving Energy efficiency

2
16 22 24* 26 28 30 32 34 36 38 40 42 44 (HP) COP 12.6% UP
130
8,10,12HP : AJYA72GALH / AJYA90GALH / AJY108GALH
14,16HP : AJY126GALH / AJY144GALH

SPLIT
MULTI SPLIT
8, 10, 12 HP 14, 16 HP

Dimensions
(Unit : mm)

8, 10, 12 HP 690 (Bolt pitch)

80 530
(Bolt pitch) 8-12 × 17 (Hole)

VRF
732 (Bolt pitch)

765 930

OPTIONAL PARTS
1690
1576

1339

A
Front side knockout position
73 Ø 34.5
Power supply cable port
43 Ø 43.7
Power supply cable port
Ø 50
Power supply Ø 22.2
cable port Transmission cable port
B A C
Ø 22.2
Transmission cable port
95
75

Pipe port
10

14, 16 HP 1000 (Bolt pitch) 125


100

199
80 840 (Bolt pitch)
8-12×7 (Hole)
VENTILATION

B
Left side knockout position
732 (Bolt pitch)

Ø 34.5
Ø 50 Power supply cable port
Power supply
cable port Ø 43.7
Power supply cable port

Ø 22.2 Ø 22.2
Transmission Transmission
765 1240 cable port cable port

C
Bottom side knockout position

Pipe port
1690

Top view
TRAINING
80
82

42 197

B A C

131
PRODUCT LINEUP: VRF-AIRSTAGE V-Series TM

Outdoor units specifications


Space Saving Combination
Rating Capacity range HP 8 10 12 14 16 18 20 22 24

Set Model name AJYA72GALH AJYA90GALH AJY108GALH AJY126GALH AJY144GALH AJY162GALH AJY180GALH AJY198GALH AJY216GALH
Unit 1 AJYA72GALH AJYA90GALH AJY108GALH AJY126GALH AJY144GALH AJYA90GALH AJYA90GALH AJY108GALH AJY108GALH
Unit 2 AJYA72GALH AJYA90GALH AJYA90GALH AJY108GALH
Unit 3
Maximum Connectable Indoor Unit*1 15 16 17 21 24 27 30 32 35
Indoor unit connectable capacity kW 11.2-33.6 14.0-42.0 16.8-50.2 20.0-60.0 22.5-67.5 25.2-75.6 28.0-84.0 30.8-92.2 33.5-100.5

Power source 3-phase 4 wire , 400 V, 50Hz


Cooling 22.4 28.0 33.5 40.0 45.0 50.4 56.0 61.5 67.0
Capacity kW
Heating 25.0 31.5 37.5 45.0 50.0 56.5 63.0 69.0 75.0
Cooling 5.45 7.11 9.75 11.34 13.61 12.56 14.22 16.86 19.50
Input power kW
Heating 5.70 7.33 9.62 10.90 12.77 13.03 14.66 16.95 19.24
EER/SEER (LOT21) Cooling W/W 4.11/5.68 3.94/5.44 3.44/5.36 3.53/5.79 3.31/5.47 4.01 3.94 3.65 3.44
COP/SCOP (LOT21) Heating W/W 4.39/3.62 4.30/3.51 3.90/3.52 4.13/4.11 3.92/4.09 4.34 4.30 4.07 3.90
$LUÁRZUDWH m3/h 11,100 11,100 11,100 13,000 13,000 11,100×2 11,100×2 11,100×2 11,100×2
Sound pressure level*2/Cooling 56 / 77 58 / 79 59 / 80 60 / 81 61 / 82 60 / 81 61 / 82 62 / 83 62 / 83
dB(A)
Power level Heating 58 / 80 59 / 81 61 / 83 61 / 83 61 / 83 62 / 84 62 / 84 63 / 85 64 / 86
Maximum external static pressure Pa 80 80 80 80 80 80 80 80 80
Compressor motor output kW 7.5 7.5 7.5 11.0 11.0 7.5×2 7.5×2 7.5×2 7.5×2
Minimum Recommended MCB AMP 20 25 25 40 40 25 + 20 25 + 25 25 + 25 25 + 25
Height 1,690 1,690 1,690 1,690 1,690 1,690 1,690 1,690 1,690
Net Dimensions Width mm 930 930 930 1,240 1,240 930×2 930×2 930×2 930×2
Depth 765 765 765 765 765 765 765 765 765
Weight kg 262 262 262 286 286 262×2 262×2 262×2 262×2
Type R410A R410A R410A R410A R410A R410A R410A R410A R410A
Refrigerant
Charge kg 11.8 11.8 11.8 11.8 11.8 11.8×2 11.8×2 11.8×2 11.8×2
Liquid 1/2 1/2 1/2 1/2 1/2 5/8 5/8 5/8 5/8
Connection pipe
Discharge Gas Inch 5/8 3/4 3/4 7/8 7/8 7/8 7/8 1 1/8 1 1/8
diameter
Suction Gas 7/8 7/8 1 1/8 1 1/8 1 1/8 1 1/8 1 1/8 1 3/8 1 3/8
Cooling -10 to 46 -10 to 46 -10 to 46 -10 to 46 -10 to 46 -10 to 46 -10 to 46 -10 to 46 -10 to 46
Operation range Heating Ý&'% -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21
Cooling/Heating -10 to 21 -10 to 21 -10 to 21 -10 to 21 -10 to 21 -10 to 21 -10 to 21 -10 to 21 -10 to 21

Energy Efficiency Combination


Rating Capacity range HP 16 22 24 26 28 30

Set Model name AJY144GALHH AJY198GALHH AJY216GALHH AJY234GALHH AJY252GALHH AJY270GALHH


Unit 1 AJYA72GALH AJY126GALH AJYA72GALH AJYA90GALH AJYA90GALH AJYA90GALH
Unit 2 AJYA72GALH AJYA72GALH AJYA72GALH AJYA72GALH AJYA90GALH AJYA90GALH
Unit 3 AJYA72GALH AJYA72GALH AJYA72GALH AJYA90GALH
Maximum Connectable Indoor Unit*1 24 33 36 39 42 45
Indoor unit connectable capacity kW 22.4-67.2 31.2-93.6 33.6-100.8 36.4-109.2 39.2-117.6 42.0-126.0

Power source 3-phase 4 wire , 400 V, 50Hz


Cooling 44.8 62.4 67.2 72.8 78.4 84.0
Capacity kW
Heating 50.0 70.0 75.0 81.5 88.0 94.5
Cooling 10.90 16.79 16.35 18.01 19.67 21.33
Input power kW
Heating 11.40 16.60 17.10 18.73 20.36 21.99
EER Cooling W/W 4.11 3.72 4.11 4.04 3.99 3.94
COP Heating W/W 4.39 4.22 4.39 4.35 4.32 4.30
$LUÁRZUDWH m3/h 11,100×2 13,000+11,100 11,100×3 11,100×3 11,100×3 11,100×3
Sound pressure level*2/Cooling 59 / 80 61 / 82 61 / 82 62 / 83 62 / 83 63 / 84
dB(A)
Power level Heating 61 / 83 63 / 85 63 / 85 63 / 85 63 / 85 64 / 86
Maximum external static pressure Pa 80 80 80 80 80 80
Compressor motor output kW 7.5×2 11.0+7.5 7.5×3 7.5×3 7.5×3 7.5×3
Minimum Recommended MCB AMP 20 + 20 40 + 20 20 + 20 + 20 20 + 20 + 20 25 + 25 + 20 25 + 25 + 25
Height 1,690 1,690 1,690 1,690 1,690 1,690
Net Dimensions Width mm 930×2 1,240+930 930×3 930×3 930×3 930×3
Depth 765 765 765 765 765 765
Weight kg 262×2 286+262 262×3 262×3 262×3 262×3
Type R410A R410A R410A R410A R410A R410A
Refrigerant
Charge kg 11.8×2 11.8×2 11.8×3 11.8×3 11.8×3 11.8×3
Liquid 1/2 5/8 5/8 5/8 5/8 3/4
Connection pipe
Discharge Gas Inch 7/8 1 1/8 1 1/8 1 1/8 1 1/8 1 /18
diameter
Suction Gas 1 1/8 1 3/8 1 3/8 1 3/8 1 3/8 1 3/8
Cooling -10 to 46 -10 to 46 -10 to 46 -10 to 46 -10 to 46 -10 to 46
Operation range Heating Ý&'% -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21
Cooling/Heating -10 to 21 -10 to 21 -10 to 21 -10 to 21 -10 to 21 -10 to 21

Note: Specifications are based on the following conditions. Pipe length: 7.5 m; Height difference between outdoor unit and indoor unit : 0 m.
Cooling: Indoor temperature of 27°CDB / 19°CWB, and outdoor temperature of 35°CDB / 24°CWB. When cooling operation will be conducted at outdoor air temperature below -5°C,
Heating: Indoor temperature of 20°CDB / (15°CWB), and outdoor temperature of 7°CDB / 6°CWB. the outdoor unit must be installed in a position that is higher than or equal to those of indoor units.

132
SPLIT
26 28 30 32 34 36 38 40 42 44 46 48

AJY234GALH AJY252GALH AJY270GALH AJY288GALH AJY306GALH AJY324GALH AJY342GALH AJY360GALH AJY378GALH AJY396GALH AJY414GALH AJY432GALH
AJY144GALH AJY144GALH AJY144GALH AJY144GALH AJY108GALH AJY108GALH AJY144GALH AJY144GALH AJY144GALH AJY144GALH AJY144GALH AJY144GALH
AJYA90GALH AJY108GALH AJY126GALH AJY144GALH AJY108GALH AJY108GALH AJY108GALH AJY108GALH AJY144GALH AJY144GALH AJY144GALH AJY144GALH
AJYA90GALH AJY108GALH AJYA90GALH AJY108GALH AJYA90GALH AJY108GALH AJY126GALH AJY144GALH
39 42 45 48 50 53 57 60 63 64 64 64
36.5-109.5 39.3-117.7 42.5-127.5 45.0-135.0 47.5-142.5 50.3-150.7 53.3-159.7 56.0-168.0 59.0-177.0 61.8-185.2 65.0-195.0 67.5-202.5

3-phase 4 wire , 400 V, 50Hz

MULTI SPLIT
73.0 78.5 85.0 90.0 95.0 100.5 106.5 112.0 118.0 123.5 130.0 135.0
81.5 87.5 95.0 100.0 106.5 112.5 119.0 125.0 131.5 137.5 145.0 150.0
20.72 23.36 24.95 27.22 26.61 29.25 30.47 33.11 34.33 36.97 38.56 40.83
20.10 22.39 23.67 25.54 26.57 28.86 29.72 32.01 32.87 35.16 36.44 38.31
3.52 3.36 3.41 3.31 3.57 3.44 3.50 3.38 3.44 3.34 3.37 3.31
4.05 3.91 4.01 3.92 4.01 3.90 4.00 3.91 4.00 3.91 3.98 3.92
13,000+11,100 13,000+11,100 13,000×2 13,000×2 11,100×3 11,100×3 13,000+11,100×2 13,000+11,100×2 13,000×2+11,100 13,000×2+11,100 13,000×3 13,000×3
63 / 84 63 / 84 64 / 84.5 64 / 85 63 / 85 64 / 85 64 / 85 65 / 85.5 65 / 86 65 / 86 65 / 86 66 / 87
63 / 85 64 / 86 64 / 86 64 / 86 65 / 87.2 65 / 87 65 / 87 66 / 87.7 65 / 87 66 / 88 66 / 88 66 / 88
80 80 80 80 80 80 80 80 80 80 80 80
11.0+7.5 11.0+7.5 11.0×2 11.0×2 7.5×3 7.5×3 11.0+7.5×2 11.0+7.5×2 11.0×2+7.5 11.0×2+7.5 11.0×3 11.0×3
40 + 25 40 + 25 40 + 40 40 + 40 25 + 25 + 25 25 + 25 + 25 40 + 25 + 25 40 + 25 + 25 40 + 40 + 25 40 + 40 + 25 40 + 40 + 40 40 + 40 + 40
1,690 1,690 1,690 1,690 1,690 1,690 1,690 1,690 1,690 1,690 1,690 1,690
1,240+930 1,240+930 1,240×2 1,240×2 930×3 930×3 1,240+930×2 1,240+930×2 1,240×2+930 1,240×2+930 1,240×3 1,240×3
765 765 765 765 765 765 765 765 765 765 765 765
286+262 286+262 286×2 286×2 286×3 286×3 286+262×2 286+262×2 286×2+262 286×2+262 286×3 286×3
R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A

VRF
11.8×2 11.8×2 11.8×2 11.8×2 11.8×3 11.8×3 11.8×3 11.8×3 11.8×3 11.8×3 11.8×3 11.8×3
5/8 5/8 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4
1 1/8 1 1/8 1 1/8 1 1/8 1 1/8 1 1/8 1 3/8 1 3/8 1 3/8 1 3/8 1 3/8 1 3/8
1 3/8 1 3/8 1 3/8 1 3/8 1 3/8 1 5/8 1 5/8 1 5/8 1 5/8 1 5/8 1 5/8 1 5/8
-10 to 46 -10 to 46 -10 to 46 -10 to 46 -10 to 46 -10 to 46 -10 to 46 -10 to 46 -10 to 46 -10 to 46 -10 to 46 -10 to 46
-20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21
-10 to 21 -10 to 21 -10 to 21 -10 to 21 -10 to 21 -10 to 21 -10 to 21 -10 to 21 -10 to 21 -10 to 21 -10 to 21 -10 to 21

32 34 36 38 40 42 44

OPTIONAL PARTS
AJY288GALHH AJY306GALHH AJY324GALHH AJY342GALHH AJY360GALHH AJY378GALHH AJY396GALHH
AJY126GALH AJY126GALH AJY126GALH AJY126GALH AJY144GALH AJY126GALH AJY144GALH
AJYA90GALH AJYA90GALH AJY126GALH AJY126GALH AJY126GALH AJY126GALH AJY126GALH
AJYA72GALH AJYA90GALH AJYA72GALH AJYA90GALH AJYA90GALH AJY126GALH AJY126GALH
48 51 54 57 60 64 64
45.2-135.6 48.0-144.0 51.2-153.6 54.0-162.0 56.5-169.5 60.0-180.0 62.5-187.5

3-phase 4 wire , 400 V, 50Hz


90.4 96.0 102.4 108.0 113.0 120.0 125.0
101.5 108.0 115.0 121.5 126.5 135.0 140.0
23.90 25.56 28.13 29.79 32.06 34.02 36.29
23.93 25.56 27.50 29.13 31.00 32.70 34.57
3.78 3.76 3.64 3.63 3.52 3.53 3.44
VENTILATION

4.24 4.23 4.18 4.17 4.08 4.13 4.05


13,000+11,100×2 13,000+11,100×2 13,000×2+11,100 13,000×2+11,100 13,000×2+11,100 13,000×3 13,000×3
63 / 84 64 / 85 64 / 85 64 / 86 65 / 86 65 / 86 65 / 86
64 / 86 65 / 87 65 / 87 65 / 87 65 / 87 66 / 88 66 / 88
80 80 80 80 80 80 80
11.0+7.5×2 11.0+7.5×2 11.0×2+7.5 11.0×2+7.5 11.0×2+7.5 11.0×3 11.0×3
40 + 25 + 20 40 + 25 + 25 40 + 40 + 20 40 + 40 + 25 40 + 40 + 25 40 + 40 + 40 40 + 40 + 40
1,690 1,690 1,690 1,690 1,690 1,690 1,690
1,240+930×2 1,240+930×2 1,240×2+930 1,240×2+930 1,240×2+930 1,240×3 1,240×3
765 765 765 765 765 765 765
286+262×2 286+262×2 286×2+262 286×2+262 286×2+262 286×3 286×3
R410A R410A R410A R410A R410A R410A R410A
11.8×3 11.8×3 11.8×3 11.8×3 11.8×3 11.8×3 11.8×3
3/4 3/4 3/4 3/4 3/4 3/4 3/4
1 1/8 1 1/8 1 1/8 1 3/8 1 3/8 1 3/8 1 3/8
1 3/8 1 3/8 1 5/8 1 5/8 1 5/8 1 5/8 1 5/8
TRAINING

-10 to 46 -10 to 46 -10 to 46 -10 to 46 -10 to 46 -10 to 46 -10 to 46


-20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21
-10 to 21 -10 to 21 -10 to 21 -10 to 21 -10 to 21 -10 to 21 -10 to 21

*1: Minimum connectable indoor unit number is 2.


*2: The noise value is the value when measured in an anechoic room. When measured in the actual installed state,
surrounding noise and reflections are received and the measured value is usually larger than the indicated value.

133
PRODUCT LINEUP: VRF-AIRSTAGE V-Series TM

Heat Pump
Modular Type

Efficiency in actual operation


Top class high COP is achieved for all combinations by our unique heat exchanger structure,
high efficient DC twin compressor, and our own technologies.

(COP) 5 4.84
4.35 4.34 4.34 4.28
4.03 4.15
3.90 3.90 3.83 4.02 3.95
Space saving 4 3.67 3.67 3.67 3.67 3.67
3.81 3.81 3.81
3.67 3.67 3.67 3.67
combination

2
8 10 12 14 16 18 20 22 24* 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 (HP)

(COP) 5 4.84 4.84


4.55 4.52 4.63 4.61
4.42 4.45 4.30 4.34 For 24 HP Combination
4.21 4.11
4.03 Space saving Energy efficiency
3.89
4 3.77
Energy efficiency
combination
3

2
COP 17% UP
16 18 20 24* 26 28 30 32 34 36 38 40 42 44 48 (HP)

System configuration example


Outdoor unit
• This system is used for medium-sized and large buildings.
Connecting each outdoor unit makes it possible to create a Separation tube Header
high capacity system.
• Connection of multiple indoor units using separation tubes
and headers.

Indoor unit
Liquid pipe
Gas pipe

Indoor unit

134
8,10HP: AJY072LALBH / AJY090LALBH
12,14,16,18HP: AJY108LALBH / AJY126LALBH / AJY144LALBH / AJY162LALBH

SPLIT
MULTI SPLIT
8, 10 HP 12, 14, 16, 18 HP

Dimensions
(Unit : mm)

8, 10 HP 690 (Bolt pitch)

80 530
(Bolt pitch) 8-12 × 17 (Hole)

VRF
732 (Bolt pitch)

765 930

OPTIONAL PARTS
1690
1576

1339

A
Front side knockout position
73 Ø 34.5
Power supply cable port
43 Ø 43.7
Power supply cable port
Ø 50
Power supply Ø 22.2
cable port Transmission cable port
B A C
Ø 22.2
Transmission cable port
95
75

Pipe port
10

12, 14, 16, 18 HP 1000 (Bolt pitch) 125


100

199
80 840 (Bolt pitch)
8-12×7 (Hole)
VENTILATION

B
Left side knockout position
732 (Bolt pitch)

Ø 34.5
Ø 50 Power supply cable port
Power supply
cable port Ø 43.7
Power supply cable port

Ø 22.2 Ø 22.2
Transmission Transmission
765 1240 cable port cable port

C
Bottom side knockout position

Pipe port
1690

Top view
TRAINING
80
82

42 197

B A C

135
PRODUCT LINEUP: VRF-AIRSTAGE V-Series TM

Outdoor units specifications

Space Saving Combination


Rating Capacity range HP 8 10 12 14 16 18 20 22 24 26 28

Set Model name AJY072LALBH AJY090LALBH AJY108LALBH AJY126LALBH AJY144LALBH AJY162LALBH AJY180LALBH AJY198LALBH AJY216LALBH AJY234LALBH AJY252LALBH
Unit 1 AJY072LALBH AJY090LALBH AJY108LALBH AJY126LALBH AJY144LALBH AJY162LALBH AJY090LALBH AJY126LALBH AJY126LALBH AJY144LALBH AJY162LALBH
Unit 2 AJY090LALBH AJY072LALBH AJY090LALBH AJY090LALBH AJY090LALBH
Unit 3
Maximum Connectable Indoor Unit*1 17 21 26 30 34 39 43 47 52 56 60
Indoor unit connectable capacity kW 11.2-33.6 14.0-42.0 16.8-50.2 20.0-60.0 22.5-67.5 25.0-67.5 28.0-84.0 31.2-93.6 34.0-102.0 36.5-109.5 39.0-109.5

Power source 3-phase 4 wire, 400 V, 50Hz


Cooling 22.4 28.0 33.5 40.0 45.0 50.0 56.0 62.4 68.0 73.0 78.0
Capacity kW
Heating 25.0 31.5 37.5 45.0 50.0 50.0 63.0 70.0 76.5 81.5 81.5
Cooling 5.20 7.28 8.96 10.96 13.01 16.56 14.56 16.16 18.24 20.29 23.84
Input power kW
Heating 5.17 7.25 8.65 11.17 13.63 13.63 14.50 16.34 18.42 20.88 20.88
EER/SEER (LOT21) Cooling W/W 4.31/5.95 3.85/5.86 3.74/6.22 3.65/6.50 3.46/6.33 3.02/5.77 3.85 3.86 3.73 3.60 3.27
COP/SCOP (LOT21) Heating W/W 4.84/3.97 4.35/3.76 4.34/3.56 4.03/4.14 3.67/4.06 3.67/3.56 4.34 4.28 4.15 3.90 3.90
$LUÁRZUDWH High m3/h 11,100 11,100 13,000 13,000 13,700 13,700 11,100×2 13,000+11,100 13,000+11,100 13,000+11,100 13,700+11,100
Sound pressure level*2/ Cooling 56 / 77 58 / 79 57 / 78 60 / 81 62 / 83 63 / 84 61 / 82 61 / 82 62 / 83 63 / 84 64 / 85
dB(A)
Power level Heating 58 / 80 59 / 81 60 / 83 62 / 84 64 / 86 64 / 86 62 / 84 63 / 85 64 / 86 65 / 87 65 / 87
Maximum external static pressure Pa 82 82 82 82 82 82 82 82 82 82 82
Compressor motor output kW 7.5 7.5 11.0 11.0 11.0 11.0 7.5×2 11.0+7.5 11.0+7.5 11.0+7.5 11.0+7.5
Minimum Recommended MCB AMP 20 25 25 40 40 40 25 + 25 40 + 20 40 + 25 40 + 25 40 + 25
Height 1,690 1,690 1,690 1,690 1,690 1,690 1,690 1,690 1,690 1,690 1,690
Net Dimensions Width mm 930 930 1,240 1,240 1,240 1,240 930×2 1,240+930 1,240+930 1,240+930 1,240+930
Depth 765 765 765 765 765 765 765 765 765 765 765
Weight kg 252 252 275 275 275 275 252×2 275+252 275+252 275+252 275+252
Type R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A
Refrigerant
Charge kg 11.7 11.7 11.8 11.8 11.8 11.8 11.7×2 11.8+11.7 11.8+11.7 11.8+11.7 11.8+11.7
Connection pipe Liquid 1/2 1/2 1/2 1/2 1/2 5/8 5/8 5/8 5/8 5/8 5/8
Inch
diameter Gas 7/8 7/8 1 1/8 1 1/8 1 1/8 1 1/8 1 1/8 1 3/8 1 3/8 1 3/8 1 3/8
Cooling -15 to 46 -15 to 46 -15 to 46 -15 to 46 -15 to 46 -15 to 46 -5 to 46 -5 to 46 -5 to 46 -5 to 46 -5 to 46
Operation range Ý&'%
Heating -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21

Energy Efficiency Combination


Rating Capacity range HP 16 18 20 24 26 28 30

Set Model name AJY144LALBHH AJY162LALBHH AJY180LALBHH AJY216LALBHH AJY234LALBHH AJY252LALBHH AJY270LALBHH
Unit 1 AJY072LALBH AJY090LALBH AJY108LALBH AJY072LALBH AJY090LALBH AJY108LALBH AJY126LALBH
Unit 2 AJY072LALBH AJY072LALBH AJY072LALBH AJY072LALBH AJY072LALBH AJY072LALBH AJY072LALBH
Unit 3 AJY072LALBH AJY072LALBH AJY072LALBH AJY072LALBH
Maximum Connectable Indoor Unit*1 34 39 43 52 56 60 64
Indoor unit connectable capacity kW 22.4-67.2 25.2-75.6 28.0-83.8 33.6-100.8 36.4-109.2 39.2-117.4 42.4-127.2

Power source 3-phase 4 wire, 400 V, 50Hz


Cooling 44.8 50.4 55.9 67.2 72.8 78.3 84.8
Capacity kW
Heating 50.0 56.5 62.5 75.0 81.5 87.5 95.0
Cooling 10.40 12.48 14.16 15.60 17.68 19.36 21.36
Input power kW
Heating 10.34 12.42 13.82 15.51 17.59 18.99 21.51
EER Cooling W/W 4.31 4.04 3.95 4.31 4.12 4.04 3.97
COP Heating W/W 4.84 4.55 4.52 4.84 4.63 4.61 4.42
$LUÁRZUDWH High m3/h 11,100×2 11,100×2 13,000+11,100 11,100×3 11,000×3 13,000+11,100×2 13,000+11,100×2
Sound pressure level*2/ Cooling 59 / 80 60 / 81 60 / 81 61 / 82 62 / 83 61 / 82 63 / 84
dB(A)
Power level Heating 61 / 83 62 / 84 62 / 85 63 / 85 63 / 85 64 / 86 65 / 87
Maximum external static pressure Pa 82 82 82 82 82 82 82
Compressor motor output kW 7.5×2 7.5×2 11.0+7.5 7.5×3 7.5×3 11.0+7.5×2 11.0+7.5×2
Minimum Recommended MCB AMP 20 + 20 25 + 20 40 + 20 20 + 20 + 20 25 + 20 + 20 40 + 20 + 20 40 + 20 + 20
Height 1,690 1,690 1,690 1,690 1,690 1,690 1,690
Net Dimensions Width mm 930×2 930×2 1,240+930 930×3 930×3 1,240+930×2 1,240+930×2
Depth 765 765 765 765 765 765 765
Weight kg 252×2 252×2 275+252 252×3 252×3 275+252×2 275+252×2
Type R410A R410A R410A R410A R410A R410A R410A
Refrigerant
Charge kg 11.7×2 11.7×2 11.8+11.7 11.7×3 11.7×3 11.8+11.7×2 11.8+11.7×2
Connection pipe Liquid 1/2 5/8 5/8 5/8 5/8 5/8 3/4
Inch
diameter Gas 1 1/8 1 1/8 1 1/8 1 3/8 1 3/8 1 3/8 1 3/8
Cooling -5 to 46 -5 to 46 -5 to 46 -5 to 46 -5 to 46 -5 to 46 -5 to 46
Operation range Ý&'%
Heating -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21

Note : Specifications are based on the following conditions. Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m.
Cooling : Indoor temperature of 27°CDB / 19°CWB, and outdoor temperature of 35°CDB / 24°CWB. When cooling operation will be conducted at outdoor air temperature below -5°C,
Heating : Indoor temperature of 20°CDB / (15°CWB), and outdoor temperature of 7°CDB / 6°CWB. the outdoor unit must be installed in a position that is higher than or equal to those of indoor units.

136
SPLIT
30 32 34 36 38 40 42 44 46 48 50 52 54

AJY270LALBH AJY288LALBH AJY306LALBH AJY324LALBH AJY342LALBH AJY360LALBH AJY378LALBH AJY396LALBH AJY414LALBH AJY432LALBH AJY450LALBH AJY468LALBH AJY486LALBH
AJY144LALBH AJY144LALBH AJY162LALBH AJY162LALBH AJY162LALBH AJY144LALBH AJY144LALBH AJY162LALBH AJY162LALBH AJY144LALBH AJY162LALBH AJY162LALBH AJY162LALBH
AJY126LALBH AJY144LALBH AJY144LALBH AJY162LALBH AJY090LALBH AJY126LALBH AJY144LALBH AJY144LALBH AJY162LALBH AJY144LALBH AJY144LALBH AJY162LALBH AJY162LALBH
AJY090LALBH AJY090LALBH AJY090LALBH AJY090LALBH AJY090LALBH AJY144LALBH AJY144LALBH AJY144LALBH AJY162LALBH
64 64 64 64 64 64 64 64 64 64 64 64 64

MULTI SPLIT
42.5-127.5 45.0-135.0 47.5-135.0 50.0-135.0 53.0-151.5 56.5-169.5 59.0-177.0 61.5-177.0 64.0-177.0 67.5-202.5 70.0-202.5 72.5-202.5 75.0-202.5

3-phase 4 wire, 400 V, 50Hz


85.0 90.0 95.0 100.0 106.0 113.0 118.0 123.0 128.0 135.0 140.0 145.0 150.0
95.0 100.0 100.0 100.0 113.0 126.5 131.5 131.5 131.5 150.0 150.0 150.0 150.0
23.97 26.02 29.57 33.12 31.12 31.25 33.30 36.85 40.40 39.03 42.58 46.13 49.68
24.80 27.26 27.26 27.26 28.13 32.05 34.51 34.51 34.51 40.89 40.89 40.89 40.89
3.55 3.46 3.21 3.02 3.41 3.62 3.54 3.34 3.17 3.46 3.29 3.14 3.02
3.83 3.67 3.67 3.67 4.02 3.95 3.81 3.81 3.81 3.67 3.67 3.67 3.67
13,700+13,000 13,700×2 13,700×2 13,700×2 13,700+11,100×2 13,700+13,000+11,100 13,700×2+11,100 13,700×2+11,100 13,700×2+11,100 13,700×3 13,700×3 13,700×3 13,700×3
64 / 85 65 / 88 66 / 87 66 / 87 65 / 86 65 / 86 66 / 87 66 / 87 67 / 87 67 / 88 67 / 88 67 / 88 68 / 89
66 / 88 67 / 89 67 / 89 67 / 89 66 / 88 67 / 89 68 / 90 68 / 90 68 / 90 69 / 91 69 / 91 69 / 91 69 / 91
82 82 82 82 82 82 82 82 82 82 82 82 82
11.0×2 11.0×2 11.0×2 11.0×2 11.0+7.5×2 11.0×2+7.5 11.0×2+7.5 11.0×2+7.5 11.0×2+7.5 11.0×3 11.0×3 11.0×3 11.0×3
40 + 40 40 + 40 40 + 40 40 + 40 40 + 25 + 25 40 + 40 + 25 40 + 40 + 25 40 + 40 + 25 40 + 40 + 25 40 + 40 + 40 40 + 40 + 40 40 + 40 + 40 40 + 40 + 40
1,690 1,690 1,690 1,690 1,690 1,690 1,690 1,690 1,690 1,690 1,690 1,690 1,690
1,240×2 1,240×2 1,240×2 1,240×2 1,240+930×2 1,240×2+930 1,240×2+930 1,240×2+930 1,240×2+930 1,240×3 1,240×3 1,240×3 1,240×3
765 765 765 765 765 765 765 765 765 765 765 765 765

VRF
275×2 275×2 275×2 275×2 275+252×2 275×2+252 275×2+252 275×2+252 275×2+252 275×3 275×3 275×3 275×3
R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A
11.8×2 11.8×2 11.8×2 11.8×2 11.8+11.7×2 11.8×2+11.7 11.8×2+11.7 11.8×2+11.7 11.8×2+11.7 11.8×3 11.8×3 11.8×3 11.8×3
3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4
1 3/8 1 3/8 1 3/8 1 5/8 1 5/8 1 5/8 1 5/8 1 5/8 1 5/8 1 5/8 1 5/8 1 5/8 1 5/8
-5 to 46 -5 to 46 -5 to 46 -5 to 46 -5 to 46 -5 to 46 -5 to 46 -5 to 46 -5 to 46 -5 to 46 -5 to 46 -5 to 46 -5 to 46
-20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21

32 34 36 38 40 42 44 46

OPTIONAL PARTS
AJY288LALBHH AJY306LALBHH AJY324LALBHH AJY342LALBHH AJY360LALBHH AJY378LALBHH AJY396LALBHH AJY414LALBHH
AJY108LALBH AJY126LALBH AJY108LALBH AJY126LALBH AJY126LALBH AJY126LALBH AJY144LALBH AJY144LALBH
AJY108LALBH AJY108LALBH AJY108LALBH AJY108LALBH AJY126LALBH AJY126LALBH AJY126LALBH AJY144LALBH
AJY072LALBH AJY072LALBH AJY108LALBH AJY108LALBH AJY108LALBH AJY126LALBH AJY126LALBH AJY126LALBH
64 64 64 64 64 64
44.7-134.1 48.0-143.8 50.3-150.7 53.5-160.5 56.8-170.2 60.0-180.0 62.5-187.5 65.0-195.0

3-phase 4 wire, 400 V, 50Hz


89.4 95.9 100.5 107.0 113.5 120.0 125.0 130.0
100.0 107.5 112.5 120.0 127.5 135.0 140.0 145.0
23.12 25.12 26.88 28.88 30.88 32.88 34.93 36.98
22.47 24.99 25.95 28.47 30.99 33.51 35.97 38.43
VENTILATION

3.87 3.82 3.74 3.70 3.68 3.65 3.58 3.52


4.45 4.30 4.34 4.21 4.11 4.03 3.89 3.77
13,000×2+11,100 13,000×2+11,100 13,000×3 13,000×3 13,000×3 13,000×3 13,700+13,000×2 13,700×2+13,000
61 / 82 63 / 84 63 / 83 64 / 84 64 / 85 65 / 88 66 / 87 66 / 87
64 / 87 65 / 88 65 / 88 65 / 88 66 / 88 67 / 89 68 / 90 68 / 90
82 82 82 82 82 82 82 82
11.0×2+7.5 11.0×2+7.5 11.0×3 11.0×3 11.0×3 11.0×3 11.0×3 11.0×3
40 + 40 + 20 40 + 40 + 20 40 + 40 + 40 40 + 40 + 40 40 + 40 + 40 40 + 40 + 40 40 + 40 + 40 40 + 40 + 40
1,690 1,690 1,690 1,690 1,690 1,690 1,690 1,690
1,240×2+930 1,240×2+930 1,240×3 1,240×3 1,240×3 1,240×3 1,240×3 1,240×3
765 765 765 765 765 765 765 765
275×2+252 275×2+252 275×3 275×3 275×3 275×3 275×3 275×3
R410A R410A R410A R410A R410A R410A R410A R410A
11.8×2+11.7 11.8×2+11.7 11.8×3 11.8×3 11.8×3 11.8×3 11.8×3 11.8×3
3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4
1 3/8 1 3/8 1 5/8 1 5/8 1 5/8 1 5/8 1 5/8 1 5/8
TRAINING

-5 to 46 -5 to 46 -5 to 46 -5 to 46 -5 to 46 -5 to 46 -5 to 46 -5 to 46
-20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21

*1 Minimum connectable indoor unit number is 2. When measured in the actual installed state, surrounding noise and reflections are
However ARXC72 and ARXC90 can be used single connection. received and the measured value is usually larger than the indicated value.
*2 The noise value is the value when measured in an anechoic room.

137
PRODUCT LINEUP: VRF
VRF-INDOOR UNITS

VRF Indoor Unit Lineup


Capacity range (kW) 1.1 2.2 2.8 3.6 4.5 5.6
Model code 4 7 9 12 14 18
NEW

Compact
Grid type / Standard type AUXB04GALH AUXB07GALH AUXB09GALH AUXB12GALH AUXB14GALH AUXB18GALH

4-way Flow
Slim type
AUXD18GALH
Cassette
4-way Flow
Large type

Circular Flow
Large type
AUXK018GLAH

Mini Duct
(With drain pump)
ARXK07GCLH ARXK09GCLH ARXK12GCLH

Slim Duct
(With drain pump)
ARXD04GALH*1 ARXD07GALH ARXD09GALH ARXD12GALH ARXD14GALH ARXD18GALH
Duct
Medium
Static Pressure Duct

High
Static Pressure Duct

Floor
(*Same as Ceiling models)
ABYA12GATH ABYA14GATH ABYA18GATH

Slim Concealed Floor


Floor (*Same as Slim Duct
models)
ARXD04GALH*1 ARXD07GALH ARXD09GALH ARXD12GALH ARXD14GALH ARXD18GALH

Compact Floor
AGYA007GCAH AGYA009GCAH AGYA012GCAH AGYA014GCAH

Ceiling
ABYA12GATH ABYA14GATH ABYA18GATH

Wall Mounted
ASYA04GACH ASYA07GACH ASYA09GACH ASYA12GACH ASYA14GACH

Wall Wall Mounted


Mounted (EEV external) ASYE04GACH ASYE07GACH ASYE09GACH ASYE12GACH ASYE14GACH
With this model, connection of EV Kit is necessary.

Wall Mounted
NEW NEW
ASYA004GTAH ASYA007GTAH ASYA009GTAH ASYA012GCAH ASYA014GCAH ASYA18GBCH

138
SPLIT
7.1 9.0 10.0 11.2 12.5 14.0 18.0 22.4 25.0 28.0
24 30 34 36 45 54 60 72 90 96

AUXB24GALH

AUXD24GALH

MULTI SPLIT
AUXA30GALH AUXA36GALH AUXA45GALH AUXA54GALH

AUXK024GLAH AUXK030GLAH AUXK036GLAH AUXK045GLAH AUXK054GLAH

ARXD24GALH

ARXA24GBLH ARXA30GBLH ARXA36GBLH ARXA45GBLH

VRF
ARXC36GBTH ARXC45GATH ARXC60GATH*2 ARXC72GBTH*2 ARXC90GBTH*2 ARXC96GATH*2

ABYA24GATH

ARXD24GALH

OPTIONAL PARTS
ABYA24GATH ABYA30GATH ABYA36GATH ABYA45GATH ABYA54GATH

VENTILATION

ASYA24GBCH ASYA030GTAH ASYA034GTAH

*1: ARXD04GALH and AUXA18/24GALH cannot be connected to J-III L series. *2: ARXC60/72/90/96G can be connected to J-III L series only.
*3: Large Airflow Duct (Compact type) can be connected to J-IIIL series only. *4: Large Airflow Duct can be connected to V-III series and VR-II series.
TRAINING

139
PRODUCT LINEUP: VRF

NEW
Compact
Cassette
Grille
Compact & Comfort

Model:
AUXB04GALH / AUXB07GALH/
AUXB09GALH / AUXB12GALH/
AUXB14GALH / AUXB18GALH/
AUXB24GALH

Panel Model:
UTGUFYEW

Compact and stylish panel design


&RPSDFWDQGVW\OLVKSDQHOGHVLJQÀWVWKHJULGW\SHFHLOLQJ
It is a linear design suitable for grid shape of 600 mm × 600 mm
grid ceiling.

Flexible installation
It is suitable for ceiling of grid type and it has high degree of
freedom of installation and it can be installed beside lighting and
ventilation opening.

Easy maintenance
Maintenance is easier by removing the ceiling panel next to the The air inlet grille can be installed in various directions,
grille, maintenance can be done, and new installation of inspection so maintenance is easy.
hole is unnecessary, so construction costs can be minimised.

Ceiling

140
NEW
Wall Mounted

SPLIT
Compact & Comfort

MULTI SPLIT
Model:
ASYA012GCAH / ASYA014GCAH
(EEV Internal)

VRF
High efficient compact design High density heat exchanger
Making the tube thin:
High efficient compact design is achieved by mounting a high
density and large heat exchanger. Compact body makes it
7 mm 5 mm
Increase of heat exchanger
possible to install inconspicuously even in a meeting or office volume by high density and
room and comfortable air conditioning is provided. adopting sub heat exchanger

Even temperature

Improved heat
exchanger effectiveness

OPTIONAL PARTS
More comfort airflow Heating
Vertical airflow provides
Comfortable air conditioning is provided by mounting powerful floor level heating
our unique power diffuser.
Power diffuser

Cooling
Horizontal airflow does not blow
cool air directly at the occupants
in the room.

Power diffuser
VENTILATION

Human sensor increases more 6 Fan Speed Control Fan speed Low noise
energy saving 24 dB(A)
Multistep airflow control is possible Quiet
Energy saving operation starts automatically to suit the environment.
by detecting the motion of a person. 2 modes
Human sensor 6-Step Speed
of save operation mode and stop mode can
be selected. High

Med-H
People go out. People come back.
Med
TRAINING

Med-L

Low

Quiet

* Compatible Remote Controller is as follows:


UTY-RNRYZ2 / UTY-RLRY / UTY-RSRY / UTY-RHRY / UTY-DCGY / UTY-DTGYZ1 / UTY-ALGX / UTY-APGX

141
PRODUCT LINEUP: VRF

VRF Indoor Units Specifications

NEW
620 x 620 Compact Cassette Grille
Compact & Comfort

142
SPLIT
Compact Cassette NEW

UTGUFYEW UTGUFYCW

Model name AUXB04GALH AUXB07GALH AUXB09GALH AUXB12GALH AUXB14GALH AUXB18GALH AUXB24GALH


Power source Single-phase, ~230V, 50Hz
UK Total Cooling 0.80 1.60 2.10 2.70 3.30 4.20 5.30
UK Sensible Cooling 0.70 1.50 1.70 2.30 2.70 3.20 4.40
Capacity UK Heating kW 1.20 2.60 3.00 3.80 4.70 5.90 7.40
Nominal Cooling 1.10 2.20 2.80 3.60 4.50 5.60 7.10
Nominal Heating 1.30 2.80 3.20 4.10 5.00 6.30 8.00
Input power W 23 25 25 29 35 36 84
High 530 540 550 600 680 710 1,030
Med m3/h 420/450*1 450 450 530 590 580 830

MULTI SPLIT
$LUÁRZUDWH
Low 300/350*1 350 350 390 390 400 450
High 34 34 35 37 38 41 50
Sound pressure level Med dB(A) 28/30*1 30 30 34 34 35 44
Low 21/25*1 25 25 27 27 27 30
Net Dimensions (H × W × D) mm 245 × 570 × 570
Weight kg 15 (Grille 2.5/2.6) 17 (Grille 2.5/2.6)
Connection Liquid (Flare) 1/4 3/8
Inch
pipe diameter Gas (Flare) 1/2 5/8
Cassette Model name UTGUFYEW / UTGUFYCW
Grille Net Dimensions (H×W×D) mm 49 × 620 × 620 / 50 × 700 × 700
1RWH6SHFLILFDWLRQVDUHEDVHGRQWKHIROORZLQJFRQGLWLRQV &RROLQJ,QGRRUWHPSHUDWXUHRIÝ&'%Ý&:%DQGRXWGRRUWHPSHUDWXUHRIÝ&'%Ý&:%
 +HDWLQJ,QGRRUWHPSHUDWXUHRIÝ&'% Ý&:% DQGRXWGRRUWHPSHUDWXUHRIÝ&'%Ý&:%
Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m. Voltage : 230 [V].
*1: This value is under cooling operation.

4-way Cassette

VRF
Model name AUXD18GALH AUXD24GALH AUXA30GALH AUXA36GALH AUXA45GALH AUXA54GALH
Power source Single-phase, ~230V, 50Hz
UK Total Cooling 4.20 5.30 6.70 8.30 9.30 10.40
UK Sensible Cooling 3.90 4.80 6.00 7.10 7.70 8.40
Capacity UK Heating kW 5.90 7.40 9.30 11.60 13.00 14.90
Nominal Cooling 5.60 7.10 9.00 11.20 12.50 14.00
Nominal Heating 6.30 8.00 10.00 12.50 14.00 16.00
Input power W 39 46 59 80 99 119
High 1,150 1,280 1,600 1,800 1,900 2,000
$LUÁRZUDWH Med m3/h 940 1,040 1,300 1,300 1,370 1,370
Low 870 870 1,100 1,100 1,100 1,100
High 36 38 40 44 46 47
Sound pressure level Med dB(A) 30 33 38 38 39 39
Low 29 29 33 33 33 33
Net Dimensions (H × W × D) mm 246 × 840 × 840 (Grille 50 × 950 × 950) 288 × 840 × 840 (Grille 50 × 950 × 950)
Weight kg 22 (Grille 5.5) 27 (Grille 5.5)

OPTIONAL PARTS
Connection Liquid (Flare) 3/8
Inch
pipe diameter Gas (Flare) 5/8 3/4
Cassette Grille Model name UTGUGYAW
1RWH6SHFLILFDWLRQVDUHEDVHGRQWKHIROORZLQJFRQGLWLRQV &RROLQJ,QGRRUWHPSHUDWXUHRIÝ&'%Ý&:%DQGRXWGRRUWHPSHUDWXUHRIÝ&'%Ý&:%
 +HDWLQJ,QGRRUWHPSHUDWXUHRIÝ&'% Ý&:% DQGRXWGRRUWHPSHUDWXUHRIÝ&'%Ý&:%
Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m. Voltage : 230 [V].

Circular Flow Cassette

Model name AUXK018GLAH AUXK024GLAH AUXK030GLAH AUXK036GLAH AUXK045GLAH AUXK054GLAH


Power source Single-phase, ~230V, 50Hz
UK Total Cooling 4.20 5.30 6.70 8.30 9.30 10.40
UK Sensible Cooling 3.30 4.40 5.30 6.70 7.60 8.70
VENTILATION

Capacity UK Heating kW 5.90 7.40 9.30 11.60 13.00 14.90


Nominal Cooling 5.60 7.10 9.00 11.20 12.50 14.00
Nominal Heating 6.30 8.00 10.00 12.50 14.00 16.00
Input power W 40 40 47 61 89 116
High 1,420 1,420 1,440 1,620 1,820 2,040
Med-H 1,360 1,360 1,440 1,500 1,590 1,800
Med 1,300 1,300 1,340 1,400 1,500 1,590
$LUÁRZUDWH m3/h
Med-L 1,270 1,270 1,300 1,340 1,400 1,440
Low 1,200 1,200 1,280 1,280 1,300 1,300
Quiet 1,150 1,150 1,150 1,150 1,150 1,150
High 38 38 39 41 44 47
Med-H 37 37 38 40 42 45
Med 36 36 37 38 40 42
Sound pressure level dB(A)
Med-L 35 35 36 37 38 39
Low 34 34 35 36 36 36
Quiet 33 33 33 33 33 33
Net Dimensions (H × W × D) mm 288 x 840 x 840 (Grille 53 x 950 x 950)
Weight kg 26.5 (Grille 6.0) 29.5 (Grille 6.0)
Connection Liquid (Flare) 1/4 3/8
Inch
pipe diameter Gas (Flare) 1/2 5/8
TRAINING

Cassette Grille Model name UTGUKYCW


1RWH6SHFLILFDWLRQVDUHEDVHGRQWKHIROORZLQJFRQGLWLRQV &RROLQJ,QGRRUWHPSHUDWXUHRIÝ&'%Ý&:%DQGRXWGRRUWHPSHUDWXUHRIÝ&'%Ý&:%
 +HDWLQJ,QGRRUWHPSHUDWXUHRIÝ&'% Ý&:% DQGRXWGRRUWHPSHUDWXUHRIÝ&'%Ý&:%
Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m. Voltage : 230 [V].
When AUX*018GLAH is connected to the outdoor unit other than J-IIIL, pipe diameter should be Ø9.52/Ø15.88 (Liq/Gas)
When AUXK036GLAH, AUXK045GLAH, and AUXK054GLAH are connected to the outdoor unit other than J-IIIL, gas pipe
diameter should be Ø19.05.

143
PRODUCT LINEUP: VRF

VRF Indoor Units Specifications


Bulkhead Duct

Model name ARXK07GCLH ARXK09GCLH ARXK12GCLH


Power source Single-phase, ~230V, 50Hz
UK Total Cooling 1.60 2.10 2.70
UK Sensible Cooling 1.50 1.80 2.30
Capacity UK Heating kW 2.60 3.00 3.70
Nominal Cooling 2.20 2.80 3.60
Nominal Heating 2.80 3.20 4.00
Input power W 28 28 35
High 460 460 550
$LUÁRZUDWH Med m3/h 420 420 480
Low 370 370 410
Static pressure range 0 to 30
Pa
Standard static pressure 10
High 26 26 29
Sound pressure level Med dB(A) 24 24 26
Low 22 22 24
Net Dimensions (H × W × D) mm 198 × 700 × 450
Weight kg 15.5 16
Connection Liquid (Flare) 1/4
Inch
pipe diameter Gas (Flare) 1/2
1RWH6SHFLILFDWLRQVDUHEDVHGRQWKHIROORZLQJFRQGLWLRQV &RROLQJ,QGRRUWHPSHUDWXUHRIÝ&'%Ý&:%DQGRXWGRRUWHPSHUDWXUHRIÝ&'%Ý&:%
 +HDWLQJ,QGRRUWHPSHUDWXUHRIÝ&'% Ý&:% DQGRXWGRRUWHPSHUDWXUHRIÝ&'%Ý&:%
Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m. Voltage : 230 [V].

Slim Duct / Slim Concealed Floor

Model name ARXD04GALH ARXD07GALH ARXD09GALH ARXD12GALH ARXD14GALH ARXD18GALH ARXD24GALH


Power source Single-phase, ~230V, 50Hz
UK Total Cooling 0.80 1.60 2.10 2.70 3.30 4.20 5.30
UK Sensible Cooling 0.70 1.50 1.80 2.30 2.90 3.50 4.90
Capacity UK Heating kW 1.20 2.60 3.00 3.70 4.70 5.90 7.40
Nominal Cooling 1.10 2.20 2.80 3.60 4.50 5.60 7.10
Nominal Heating 1.30 2.80 3.20 4.00 5.00 6.30 8.00
Input power W 40 44 50 54 92 83 122
High 510 550 600 600 800 940 1,330
$LUÁRZUDWH Med m3/h 400/470*1 490 550 510 710 840 1,240
Low 320/440*1 440 480 450 610 750 1,100
Static pressure range 0 to 90 0 to 90 0 to 90 0 to 90 0 to 90 0 to 90 0 to 50
Pa
Standard static pressure 25 25 25 25 25 25 25
High 26 28 29 30 34 34 35
Sound pressure level Med dB(A) 21/25*1 25 26 27 32 32 32
Low 20/22*1 22 24 24 28 28 29
Net Dimensions (H × W × D) mm 198 × 700 × 620 198 × 900 × 620 198 × 1,100 × 620
Weight kg 17 18 22 26
Connection Liquid (Flare) 1/4 3/8
Inch
pipe diameter Gas (Flare) 1/2 5/8
1RWH6SHFLILFDWLRQVDUHEDVHGRQWKHIROORZLQJFRQGLWLRQV &RROLQJ,QGRRUWHPSHUDWXUHRIÝ&'%Ý&:%DQGRXWGRRUWHPSHUDWXUHRIÝ&'%Ý&:%
 +HDWLQJ,QGRRUWHPSHUDWXUHRIÝ&'% Ý&:% DQGRXWGRRUWHPSHUDWXUHRIÝ&'%Ý&:%
Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m. Voltage : 230 [V].
*1: This value is under cooling operation.

Medium Static Pressure Duct

Model name ARXA24GBLH ARXA30GBLH ARXA36GBLH ARXA45GBLH


Power source Single-phase, ~230V, 50Hz
UK Total Cooling 5.30 6.70 8.30 9.30
UK Sensible Cooling 4.70 5.60 7.00 7.90
Capacity UK Heating kW 7.40 9.30 11.60 13.00
Nominal Cooling 7.10 9.00 11.20 12.50
Nominal Heating 8.00 10.00 12.50 14.00
Input power W 94 108 194 240
High 1,280 1,410 1,840 1,970
$LUÁRZUDWH Med m3/h 990 1,280 1,600 1,860
Low 840 1,150 1,470 1,640
Static pressure range 0 to 150 0 to 150 0 to 150 0 to 150
Pa
Standard static pressure 40 50 50 60
High 31 34 37 41
Sound pressure level Med dB(A) 27 32 35 38
Low 23 29 33 36
Net Dimensions (H × W × D) mm 270 × 1,135 × 700
Weight kg 36 40
Connection Liquid (Flare) 3/8
Inch
pipe diameter Gas (Flare) 5/8 3/4
1RWH6SHFLILFDWLRQVDUHEDVHGRQWKHIROORZLQJFRQGLWLRQV &RROLQJ,QGRRUWHPSHUDWXUHRIÝ&'%Ý&:%DQGRXWGRRUWHPSHUDWXUHRIÝ&'%Ý&:%
 +HDWLQJ,QGRRUWHPSHUDWXUHRIÝ&'% Ý&:% DQGRXWGRRUWHPSHUDWXUHRIÝ&'%Ý&:%
Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m. Voltage : 230 [V].

144
SPLIT
High Static Pressure Duct

Model name ARXC36GBTH ARXC45GATH ARXC60GATH* ARXC72GBTH ARXC90GATH ARXC96GATH


Power source Single-phase, ~230V, 50Hz
UK Total Cooling 8.3 9.3 13.4 16.6 18.6 20.8
UK Sensible Cooling 7.4 9.2 12.2 15.1 15.6 16.7
Capacity UK Heating kW 11.6 13.0 18.6 23.3 26.0 29.3
Nominal Cooling 11.2 12.5 18.0 22.4 25.0 28.0
Nominal Heating 12.5 14.0 20.0 25.0 28.0 31.5
Input power W 207 715 730 681 819 838

MULTI SPLIT
High 1,990 3,500 3,500 3,900 4,300 4,850
$LUÁRZUDWH Med m3/h 1,680 3,000 3,000 3,300 4,000 4,250
Low 1,330 2,460 2,460 3,000 3,500 3,600
Static pressure range 0 to 200 100 to 250 100 to 250 0 to 300 0 to 300 0 to 300
Pa
Standard static pressure 100 100 100 150 150 150
High 42 49 49 47 48 48
Sound pressure level Med dB(A) 36 45 45 43 46 45
Low 32 42 42 40 44 42
Net Dimensions (H × W × D) mm 400 × 1,050 × 500 450 × 1,587 × 700 550 × 1,587 × 700
Weight kg 40 46 84 105
Connection Liquid 3/8 (Flare) 1/2 (Brazing)
inch
pipe diameter Gas 3/4 (Flare) 7/8 (Brazing)

1RWH6SHFLILFDWLRQVDUHEDVHGRQWKHIROORZLQJFRQGLWLRQV 1RPLQDO&RROLQJ,QGRRUWHPSHUDWXUHRIÝ&'%Ý&:%DQGRXWGRRUWHPSHUDWXUHRIÝ&'%Ý&:%
  1RPLQDO+HDWLQJ,QGRRUWHPSHUDWXUHRIÝ&'% Ý&:% DQGRXWGRRUWHPSHUDWXUHRIÝ&'%Ý&:%
Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m.
Voltage : 230 [V].

VRF
Floor/Ceiling

Model name ABYA12GATH ABYA14GATH ABYA18GATH ABYA24GATH


Power source Single-phase, ~230V, 50Hz
UK Total Cooling 2.70 3.30 4.20 5.30
UK Sensible Cooling 2.40 3.00 3.80 4.20
Capacity UK Heating kW 3.70 4.70 5.90 7.40
Nominal Cooling 3.60 4.50 5.60 7.10
Nominal Heating 4.00 5.00 6.30 8.00
Input power W 30 42 74 99
High 660 780 1,000 1,000
$LUÁRZUDWH Med m3/h 570 640 720 820
Low 490 550 580 680

OPTIONAL PARTS
High 36 40 46 47
Sound pressure level Med dB(A) 32 36 39 42
Low 28 34 35 37
Net Dimensions (H × W × D) mm 199 × 990 × 655
Weight kg 25 26 26 27
Connection Liquid (Flare) 1/4 3/8
Inch
pipe diameter Gas (Flare) 1/2 5/8
1RWH6SHFLILFDWLRQVDUHEDVHGRQWKHIROORZLQJFRQGLWLRQV &RROLQJ,QGRRUWHPSHUDWXUHRIÝ&'%Ý&:%DQGRXWGRRUWHPSHUDWXUHRIÝ&'%Ý&:%
  +HDWLQJ,QGRRUWHPSHUDWXUHRIÝ&'% Ý&:% DQGRXWGRRUWHPSHUDWXUHRIÝ&'%Ý&:%
Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m.
Voltage : 230 [V].

Ceiling VENTILATION

Model name ABYA30GATH ABYA36GATH ABYA45GATH ABYA54GATH


Power source Single-phase, ~230V, 50Hz
UK Total Cooling 6.70 8.30 9.30 10.40
UK Sensible Cooling 6.10 6.90 7.90 8.90
Capacity UK Heating kW 9.30 11.60 13.00 14.90
Nominal Cooling 9.00 11.20 12.50 14.00
Nominal Heating 10.00 12.50 14.00 16.00
Input power W 66 85 131 180
High 1,630 1,690 2,010 2,270
$LUÁRZUDWH Med m3/h 1,370 1,400 1,600 1,780
Low 1,140 1,170 1,230 1,280
High 42 45 48 51
Sound pressure level Med dB(A) 38 38 42 45
Low 33 34 35 36
Net Dimensions (H × W × D) mm 240 × 1,660 × 700
Weight kg 46 48
Connection Liquid (Flare) 3/8 3/8
Inch
pipe diameter Gas (Flare) 5/8 3/4
1RWH6SHFLILFDWLRQVDUHEDVHGRQWKHIROORZLQJFRQGLWLRQV &RROLQJ,QGRRUWHPSHUDWXUHRIÝ&'%Ý&:%DQGRXWGRRUWHPSHUDWXUHRIÝ&'%Ý&:%
TRAINING

  +HDWLQJ,QGRRUWHPSHUDWXUHRIÝ&'% Ý&:% DQGRXWGRRUWHPSHUDWXUHRIÝ&'%Ý&:%


Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m.
Voltage : 230 [V].

145
PRODUCT LINEUP: VRF

VRF Indoor Units Specifications


Compact Floor

Model name AGYA007GCAH AGYA009GCAH AGYA012GCAH AGYA014GCAH


Power source Single-phase, ~230V, 50Hz
UK Total Cooling 1.60 2.10 2.70 3.00
UK Sensible Cooling 1.40 1.70 2.30 2.50
Capacity UK Heating kW 2.60 3.00 3.70 4.20
Nominal Cooling 2.20 2.80 3.60 4.00
Nominal Heating 2.80 3.20 4.00 4.50
Input power W 16 17 22 29
High 470 500 590 670
Med-H 420 450 520 590
Med 390 400 470 520
$LUÁRZUDWH m3/h
Med-L 360 360 420 450
Low 330 330 390 390
Quiet 270 270 340 340
High 37 38 42 46
Med-H 35 36 39 42
Med 33 34 37 39
Sound pressure level dB(A)
Med-L 31 31 35 36
Low 29 29 33 33
Quiet 22 22 30 30
Net Dimensions (H × W × D) mm 600 x 740 x 200
Weight kg 15
Connection Liquid (Flare) 1/4
Inch
pipe diameter Gas (Flare) 3/8 1/2
1RWH6SHFLILFDWLRQVDUHEDVHGRQWKHIROORZLQJFRQGLWLRQV&RROLQJ,QGRRUWHPSHUDWXUHRIÝ&'%Ý&:%DQGRXWGRRUWHPSHUDWXUHRIÝ&'%Ý&:%
 +HDWLQJ,QGRRUWHPSHUDWXUHRIÝ&'% Ý&:% DQGRXWGRRUWHPSHUDWXUHRIÝ&'%Ý&:%
Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m. Voltage : 230 [V].
When AGY*004GCAH, AGY*007GCAH, and AGY*009GCAH are connected to the outdoor unit other than J-IIIL, gas pipe diameter should be Ø12.70.

Wall Mounted

Model name ASYA04GACH ASYA07GACH ASYA09GACH ASYA12GACH ASYA14GACH ASYE04GACH ASYE07GACH ASYE09GACH ASYE12GACH ASYE14GACH
Power source Single-phase, ~230V, 50Hz
UK Total Cooling 0.80 1.60 2.10 2.70 3.30 0.80 1.60 2.10 2.70 3.30
UK Sensible Cooling 0.70 1.60 1.90 2.30 2.80 0.70 1.60 1.90 2.30 2.80
Capacity UK Heating kW 1.20 2.60 3.00 3.80 4.70 1.20 2.60 3.00 3.80 4.70
Nominal Cooling 1.10 2.20 2.80 3.60 4.50 1.10 2.20 2.80 3.60 4.50
Nominal Heating 1.30 2.80 3.20 4.10 5.00 1.30 2.80 3.20 4.10 5.00
Input power W 13 17 18 22 34 12 15 16 21 34
High 450 490 500 560 670 450 490 500 560 680
$LUÁRZUDWH Med m3/h 370/440 htg/clg*1 450 450 480 490 370/440 htg/clg*1 450 450 480 490
Low 320/420 htg/clg*1 370/420 htg/clg*1 370/420 htg/clg*1 420 420 300/420 htg/clg*1 370/420 htg/clg*1 370/420 htg/clg*1 420 420
High 33 35 36 39 44 32 34 35 38 43
Sound pressure level Med dB(A) 27/32 htg/clg*1 33 33 35 37 26/31 htg/clg*1 32 32 34 35
Low 22/31 htg/clg*1 27/31 htg/clg*1 27/31 htg/clg*1 31 32 19/30 htg/clg*1 26/30 htg/clg*1 26/30 htg/clg*1 30 30
Net Dimensions (H × W × D) mm 275 x 790 x 215 275 x 790 x 215
Weight kg 9 9
Connection Liquid (Flare) 1/4 1/4
Inch
pipe diameter Gas (Flare) 1/2 1/2
EV Kit (option) - UTREV09XB UTREV14XB
1RWH6SHFLILFDWLRQVDUHEDVHGRQWKHIROORZLQJFRQGLWLRQV &RROLQJ,QGRRUWHPSHUDWXUHRIÝ&'%Ý&:%DQGRXWGRRUWHPSHUDWXUHRIÝ&'%Ý&:%
7KLVYDOXHLVXQGHUFRROLQJRSHUDWLRQ  +HDWLQJ,QGRRUWHPSHUDWXUHRIÝ&'% Ý&:% DQGRXWGRRUWHPSHUDWXUHRIÝ&'%Ý&:%
Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m. Voltage : 230 [V].

Wall Mounted

Model name ASYA007GTAH ASYA009GTAH ASYA18GBCH ASYA24GBCH ASYA030GTAH ASYA034GTAH


Power source Single-phase, ~230V, 50Hz
UK Total Cooling 1.60 2.10 4.20 5.30 6.70 7.40
UK Sensible Cooling 1.60 1.90 3.90 4.80 5.70 6.50
Capacity UK Heating kW 2.60 3.00 5.90 7.40 9.30 10.40
Nominal Cooling 2.20 2.80 5.60 7.10 9.00 10.00
Nominal Heating 2.80 3.20 6.30 8.00 10.00 11.20
Input power W 19 34 32 60 74 103
High 550 720 840 1,100 1,440 1,620 / 1,520
Med-H 460 570 - - 1,200 1,300
Med 420 500 770 910 1,050 1,120
$LUÁRZUDWH m3/h
Med-L 390 410 - - 940 980
Low 360 360 690 730 890 890
Quiet 330 330 - - 700 700
High 35 43 41 48 53 55 / 54
Med-H 32 38 - - 49 51
Med 30 34 39 43 45 47
Sound pressure level dB(A)
Med-L 27 29 - - 42 43
Low 24 24 35 35 39 39
Quiet 22 22 - - 33 33
Net Dimensions (H × W × D) mm 262 x 820 x 206 320 x 998 x 238 340 x 1,150 x 280
Weight kg 7.5 15 18
Connection Liquid (Flare) 1/4 3/8
Inch
pipe diameter Gas (Flare) 3/8 1/2 58
1RWH6SHFLILFDWLRQVDUHEDVHGRQWKHIROORZLQJFRQGLWLRQV &RROLQJ,QGRRUWHPSHUDWXUHRIÝ&'%Ý&:%DQGRXWGRRUWHPSHUDWXUHRIÝ&'%Ý&:%
  +HDWLQJ,QGRRUWHPSHUDWXUHRIÝ&'% Ý&:% DQGRXWGRRUWHPSHUDWXUHRIÝ&'%Ý&:%
Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m.
Voltage : 230 [V].
When ASY*004GTAH, ASY*007GTAH, ASY*009GTAH are connected to the outdoor unit other than J-IIIL, gas pipe
diameter should be Ø12.70.

146
SPLIT
Wall Mounted

NEW

Model name ASYA012GCAH ASYA014GCAH


Power source Single-phase, ~230V, 50Hz
UK Total Cooling 2.70 3.00
UK Sensible Cooling 2.30 2.70
Capacity UK Heating 3.70 4.20
Nominal Cooling 3.60 4.00
kW
Nominal Heating 4.00 4.50
Input power W 25 36

MULTI SPLIT
High 690 800
Med-H 610 740
Med 560 680
$LUÁRZUDWH m3/h
Med-L 530 610
Low 470 550
Quiet 330 330
High 40 44
Med-H 37 42
Med 35 40
Sound pressure level dB(A)
Med-L 33 37
Low 30 34
Quiet 24 24
Net Dimensions (H × W × D) mm 268 x 840 x 203
Weight kg 8.5 8.5
Connection Liquid (Flare) 6.35
mm
pipe diameter Gas (Flare) 9.52
1RWH6SHFLILFDWLRQVDUHEDVHGRQWKHIROORZLQJFRQGLWLRQV &RROLQJ,QGRRUWHPSHUDWXUHRIÝ&'%Ý&:%DQGRXWGRRUWHPSHUDWXUHRIÝ&'%Ý&:%
  +HDWLQJ,QGRRUWHPSHUDWXUHRIÝ&'% Ý&:% DQGRXWGRRUWHPSHUDWXUHRIÝ&'%Ý&:%
Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m.
Voltage : 230 [V].

VRF
Linwood now offer an extensive range of

OPTIONAL PARTS
plenum boxes to suit the Fujitsu General
Air Conditioning UK range of ducted air
conditioning indoor units

Installing air conditioning ducted fan


coil units (FCU's) just got easier with
these purpose made plenum boxes
designed to save you time and money
when fitting VRF or split air conditioning
systems VENTILATION

Easy
E asy to
to use
use online
online ordering
orderi
& li d processing
live order i via

www.airconplenums.com/fujitsu-plenum
TRAINING

147

You might also like