General Lab Inspection Checklist 2016
General Lab Inspection Checklist 2016
General Lab Inspection Checklist 2016
Background information
Date Inspector
Building Room(s)
School & Department
PI Name
Email and phone
Group Safety Officer or Name
Lab Manager Email and phone
PI
Safety Officer
Inspector Accompanied by:
Lab Manager
Other (specify)
QC:
CTI?
Finding
Days
Code Finding Details Comments OK?
Y N N/A Y Y N
Missing or out-of-date Laboratory 20
a01
Hazard Assessment Tool (LHAT).
20
Missing or incorrect chemical
a02
inventory.
inventory.
Safety Data Sheets (SDSs) and 20
Documentation and Training
Procedure to report an 20
a05 occupational injury or illness is
not posted.
Personnel have not received 20
a06 appropriate initial or refresher and discussed with personnel.
training.
1 01/21/2016 v01
LABORATORY INSPECTION CHECKLIST
QC:
CTI?
Finding
Days
Code Finding Details Comments OK?
Y N N/A Y Y N
20
Other documentation or training
a07 sheet not available.
deficiency.
Other (specify).
20
Defective building feature or
building.
b01 defective room fixtures and
fittings.
-related, e.g. defective floor. 5
b02 Tripping or slipping hazard. -related, e.g. extension cords,
pipes, spillage.
-related. 5
Obstructed passageway, PI-related.
b03 entrance, exit, door, or locked -related (e.g.
exit door. equipment in corridor)
Room
Excessive storage of
combustibles.
c01 Poor housekeeping.
Heavy items stored too high.
Combustibles stacked too close
to ceiling.
Other (specify).
2 01/21/2016 v01
LABORATORY INSPECTION CHECKLIST
QC:
CTI?
Finding
Days
Code Finding Details Comments OK?
Y N N/A Y Y N
Defective HVAC, too hot/cold, 20
c02
or poor quality of incoming air.
FMS-related. 20
Suspected asbestos or ceramic
c03 -related, e.g. furnace, heating
fiber hazard.
mantle.
Insufficient provision for hand- Needs to be at least one sink in lab 20
d01
washing. with soap and paper towels.
Defective plumbing, faucet, or Look for leaking taps, blocked 20
d02
sink. sinks, etc.
20
Water
recirculated flow.
Improvised tubing or equipment
d03 -recirculating
poses a flooding risk.
water pipework not securely
fastened.
Water damage, dampness, 20
d04 condensation, active leak, mold,
fungus, or rot.
Defective or overloaded -current devices (e.g. 5
electrical outlet and/or hotplates, furnaces) on extension
e01
inappropriate extension cord cords or overloading outlets.
usage.
Defective or obstructed electrical 20
Electrical
not up to date.
Fire extinguisher is absent, 5
incorrect type, not visible, not extinguisher (flammable metals).
f02 accessible, not hung on the wall,
is obstructed, or needs
relocation.
3 01/21/2016 v01
LABORATORY INSPECTION CHECKLIST
QC:
CTI?
Finding
Days
Code Finding Details Comments OK?
Y N N/A Y Y N
Visibly defective or obstructed 5
f03
smoke detector or sprinkler.
Emergency eyewash / shower / 20
g01 drench hose testing log not up-
to-date.
Emergency eyewash / shower /
drench hose is defective,
Safety Equipment
20
obstructed, non-code-compliant,
g02
missing, too far from lab, or
improperly signed. sec distant and/or more than one
intervening doorway).
Chemical spill cleanup supplies 20
g03
are not available. no appropriate supplies.
First aid kit / HF burn kit is not 20
available, inaccessible, missing.
g04
inappropriate, out of date, or
incorrectly signed
Improperly guarded, defective, Unguarded belt (IDLH). 20
dangerous, poorly-maintained, Contaminated.
h01 contaminated, inappropriately Other (specify).
sited, or inappropriately used
equipment.
Missing log book. 20
General Equipment
4 01/21/2016 v01
LABORATORY INSPECTION CHECKLIST
QC:
CTI?
Finding
Days
Code Finding Details Comments OK?
Y N N/A Y Y N
Uncontaminated outlet passing 20
Unsafe discharge of vacuum pump to lab without coalescing filter.
h03
exhaust Contaminated outlet passing to
lab.
Defective, excessively iced, Flammables in a non-explosion- 20
inappropriately sited, or proof unit.
i01
inappropriately used refrigerator
or freezer.
Fridge/Freezer
5 01/21/2016 v01
LABORATORY INSPECTION CHECKLIST
QC:
CTI?
Finding
Days
Code Finding Details Comments OK?
Y N N/A Y Y N
Gas cylinders not properly 20
restrained
Cylinders in storage missing end
caps.
Flammables and oxidizers not
separated.
k01 Incorrect gas cylinder storage.
Cylinders surrounded by
flammables/combustibles.
Cylinders of hazardous gases
not turned off after use.
Highly toxic gases outside
ventilated enclosures.
Hazardous materials container or 20
storage cabinet is defective,
k02 corroded, contaminated, or
Hazardous Materials
QC:
CTI?
Finding
Days
Code Finding Details Comments OK?
Y N N/A Y Y N
Incompatible chemicals stored 20
Other unsafe hazardous materials
k010 together.
storage practice.
Incorrect separation of waste 20
l01
streams.
Piranha solution or other Lab has written procedure for 5
hydrogen peroxide-containing hydrogen peroxide disposal.
l02
material in non-vented container,
or mixed with other waste
Contaminated material in regular 20
l03
trash.
Regular trash in hazardous waste 20
l04
container.
Inappropriate, damaged, un- Un-capped container. 20
l05 capped, or externally
contaminated waste container.
Missing or unsatisfactory 20
Waste
l06
secondary containment.
Free-flowing liquids More than 5 mL free-flowing 20
l07 inappropriately mixed with solid liquid in a biohazard waste
chemical or biohazardous waste. container.
Overfull container or over-large 20
l08
items in small container.
Solid waste bags are emitting an 20
l09
odor.
Items placed on top of waste 20
l010
containers.
Incorrect labelling of hazardous 20
l011
waste.
Accumulation start date on the 20
l012 chemical waste label is more than
nine months old.
Broken glass and/or sharps 20
Sharps/Bro
ken Glass
m01
container is missing.
Unattended broken glass or 0
m02
exposed sharps.
7 01/21/2016 v01
LABORATORY INSPECTION CHECKLIST
QC:
CTI?
Finding
Days
Code Finding Details Comments OK?
Y N N/A Y Y N
Sharps are being transported 0
m03
improperly.
Evidence of needle recapping was 0
m04
found.
m05 Incorrect sharps disposal. 0
m06 Incorrect broken glass disposal. 20
Broken glass container appears to 20
m07 contain contaminated material, or
is emitting an odor.
Broken glass and/or sharps 20
container is missing hazardous
m08
waste label if it is being used for
contaminated items.
Inappropriate mercury Hg thermometer in oven, or 20
n01
thermometer usage or storage. heating bath.
Mercury-containing bottle or 20
Mercury
equipment/clothing (PPE).
Re-use of disposable gloves. 5
p03 Incorrect glove usage.
Respirator usage outside of the 20
p04
EH&S respirator program.
Evidence of food/drink was found 0
Practice
hazardous materials.
8 01/21/2016 v01
LABORATORY INSPECTION CHECKLIST
QC:
CTI?
Finding
Days
Code Finding Details Comments OK?
Y N N/A Y Y N
Personnel were observed 20
touching potentially hazardous
q02 material with bare skin or leaving
work area without washing
hands.
Carcinogenic, cumulatively toxic, 5
sensitizing, or highly toxic
materials in chemical inventory,
q03 but no evidence of
engineering/administrative
controls to prevent
dispensing/weighing in open lab.
Material posing inhalation hazard 0
is used outside of fume hood, or
work requiring respiratory
q04 protection is being done in a non-
approved area where the
respiratory hazard may spread to
unprotected persons
Bottle carriers not available or Question personnel. If glass bottles 20
q05 hazardous materials observed to are ever carried from the lab, a
be transported in unsafe manner. bottle carrier must be available.
Enter improperly restrained gas 20
Seismic
9 01/21/2016 v01
LABORATORY INSPECTION CHECKLIST
Quality Control
QC Inspection by: Date:
Accompanied by:
Comments
10 01/21/2016 v01