Before configuring Layer 7 Application Control in your firewall rules, you must enable it and configure
default application handling and detection policies.
To use Layer 7 Application Control, you must have a valid Energize Updates subscription
installed on the Barracuda NG Firewall.
Setting Description
Specifies how detected applications are handled. You can select one of the
following policies:
• No-Detection - Application detection is deactivated.
• Detect-Only - Reports detected applications in the firewall access cache
but takes no action.
Application Policy • Limit-Bandwidth - Limits the bandwidth for the traffic of detected
applications. If you select this policy, you must enter the maximum
bandwidth in the Application Bandwidth field.
• Drop-Traffic - Blocks the traffic for detected applications.
• Assign-QoS-Band - Assigns a QoS band to the traffic of detected
applications, as specified by the default policy or the firewall rule.
Application
Maximum bandwidth in kilobits for the traffic of detected applications.
Bandwidth
1. In the Application Detection Default Selection section, define the applications that the
Barracuda NG Firewall must detect. By default, all supported applications are detected.
If you want to explicitly specify which applications must be detected, edit the following
settings:
Use Preselected Applications - Select no.
Explicitly Add Applications - Add an entry for each application that the
Barracuda NG Firewall must detect.
If you want to use the preselected list of applications, edit the following settings:
Use Preselected Applications - Select yes.
Explicitly Skip Applications - Add an entry for each application that the
Barracuda NG Firewall does not need to detect.
Application Detection Default Selection section:
Figures
1. app.jpg
© Barracuda Networks Inc., 2021 The information contained within this document is confidential and proprietary to Barracuda Networks Inc. No
portion of this document may be copied, distributed, publicized or used for other than internal documentary purposes without the written consent of
an official representative of Barracuda Networks Inc. All specifications are subject to change without notice. Barracuda Networks Inc. assumes no
responsibility for any inaccuracies in this document. Barracuda Networks Inc. reserves the right to change, modify, transfer, or otherwise revise this
publication without notice.