Department of Electrical & Computer Engineering: North South University Lab Report
Department of Electrical & Computer Engineering: North South University Lab Report
Course Code :
Course Title:
Section:
Experiment Number:
Experiment Name:
Experiment Date:
Date of Submission:
Course Instructor: Faculty Name
Submitted To: Lab Instructor Name
Ali Msua
Id: 1811404643
EEE 111
Sec: 06
Experiment name :
Objective:
Theory :
Zener diodes are utilized in a variety of circuits like voltage control, as reference elements,
surge suppressors, switching applications, and clipper circuits. In Zener diode The load voltage
is equal to the diode's breakdown voltage VZ. When the diode is conducting, the series resistor
restricts the current through the diode and reduces the surplus voltage. Zener diodes find wide
function in one of three modes: forward, leakage, or breakdown. The forward mode is the most
common.
Procedure:
2. Vary the supply voltage from zero volt, complete the Table 4.1.
4. Keep the POT at maximum position and power up the circuit. Apply 10 as V.
5. Gradually decrease the POT resistance and complete the Table 4.2.
6. Replace load with 1KΩ resistance, vary the supply voltage and take reading for Table 4.3.
XMM1
R1
1 2
470Ω
3
XMM2
D1
1N4733A
V1
10V
0
Data for I - V characteristics
2 628.264 1.496
3 628.502 1.209
4 628.662 1.014
5 628.777 873.301uA
6 628.863 766.907uA
7 628.931 683.621uA
8 628.985 616.653uA
9 629.03 561.634uA
10 629.067 515.629 uA
Data for regulation due supply voltage variation.
Volts (v) VL
1.0 2.128 mV
3.0 6.383 mV
6.0 12.766 mV
8 17.021 mV
9 19.149 mV
10 21.277 mV
11 23.404 mV
12 25.532 mV
Report :
• Plot the I - V characteristics of Zener diode. Determine the Zener breakdown voltage
from the plot.
12
10
0
1 2 3 4 5 6 7 8 9 10 11 12 13
Plot IL vs VL for the data table 4.2. Find the voltage regulation.
700
600
500
400
300
200
100
0
1 2 3 4 5 6 7 8 9 10 11 12
Plot VL vs V for the data table 4.3. Find the voltage regulation.
14
12
10
0
1 2 3 4 5 6 7 8 9