Victaulic AGS Rigid Coupling Style W07: 1.0 Product Description

Download as pdf or txt
Download as pdf or txt
You are on page 1of 6

Victaulic® AGS Rigid Coupling

Style W07 20.02

14 – 24"/DN350 – DN600 sizes 26 – 50"/DN650 – DN1250 sizes


Patented Patented

1.0 PRODUCT DESCRIPTION


Available Sizes
• 14 – 50"/DN350 – DN1250
Maximum Working Pressure
• 14 – 24"/DN350 – DN600: 350 psi/2400 kPa
• 26 – 42"/DN650 – DN1050: 300 psi/2065 kPa
• 44 – 50"/DN1100 – DN1250: 232 psi/1600 kPa
Function
• Unique wedge-shaped key profile increases allowable pipe end separation, resulting in easier assembly.
• Style W07 AGS coupling in 26 – 50"/ DN650 – DN1250 sizes, features lifting lugs integrated into the housings to
help ease handling during installation.
• Provide rigidity for valve connections, machinery rooms, and long straight runs.
NOTES
• Style W07 AGS couplings are provided with FlushSeal™ gaskets for a variety of services. Please specify gasket grade when ordering. Please refer to
publication 05.01 for gasket service ratings.
• Style W07 AGS rigid couplings can also be used on abrasive/slurry services in combination with an AGS Vic-Ring. See publication 16.11.

2.0 CERTIFICATION/LISTINGS

NOTES
• Sizes 377mm, 426mm and 480mm are not UL, NSF and FM approved.
• See publication 02.06 Victaulic Potable Water Approvals ANSI/NSF for potable water approvals if applicable.
• Download publication 10.01 for Fire Protection Certifications/Listings Reference Guide.

ALWAYS REFER TO ANY NOTIFICATIONS AT THE END OF THIS DOCUMENT REGARDING PRODUCT INSTALLATION, MAINTENANCE OR SUPPORT.

System No. Location Spec Section Paragraph

Submitted By Date Approved Date

victaulic.com
20.02 3852 Rev Q Updated 01/2019 © 2019 Victaulic Company. All rights reserved.
1
victaulic.com

3.0 SPECIFICATIONS – MATERIAL


Housing: Ductile iron conforming to ASTM A536, Grade 65-45-12. Ductile iron conforming to ASTM A395, Grade
65-45-15 available upon special request.
Housing Coating: (specify choice)
 Standard: Orange enamel.
Optional: Hot dipped galvanized and others.
Optional: Fusion Bonded Epoxy.
NOTE
• For additional coating options contact Victaulic.

Coupling Gasket: (specify choice1)


Victaulic Grade “E” FlushSeal™ EPDM
EPDM (Green stripe color code). Temperature range –30ºF to +230ºF/–34ºC to +110ºC. May be specified for hot
water service within the specified temperature range plus a variety of dilute acids, oil-free air and many chemical
services. UL Classified in accordance with ANSI/NSF 61 for cold +73ºF/+23ºC and hot +180ºF/+82ºC potable water
service and ANSI/NSF 372. NOT COMPATIBLE FOR USE WITH PETROLEUM SERVICES OR STEAM SERVICES.
Victaulic Grade “T” FlushSeal™ Nitrile
Nitrile (Orange color code). Temperature range –20°F to +180°F/–29°C to +82°C. May be specified for oil related
services, including air with oil vapor, this gasket may be specified for temperatures rated up to +180°F/+82°C. For
water related services, this gasket may be specified for temperatures rated up to +150°F/+66°C. For oil free, dry
air services, this gasket may be specified for temperatures rated up to +140°F/+60°C. NOT COMPATIBLE FOR
USE WITH HOT WATER SERVICES OR STEAM SERVICES.
Victaulic Grade “L” FlushSeal™ Silicone
Silicone (Red color code). Temperature range –30°F to +350°F/–34° C to +177° C. May be specified for dry heat,
air without hydrocarbons to +350°F/+177°C and certain chemical services.
Others
For alternate gasket selection, reference publication 05.01: Victaulic Seal Selection Guide – Elastomeric
Seal Construction.
1 Services listed are General Service Guidelines only. It should be noted that there are services for which these gaskets are not compatible. Reference should
always be made to the latest Victaulic Seal Selection Guide for specific gasket service guidelines and for a listing of services which are not compatible.

Bolts/Nuts: (specify choice2)


Standard: Carbon steel oval neck track bolts meeting the mechanical property requirements of ASTM A449
(imperial) and ISO 898-1 Class 9.8 (M10-M16) Class 8.8 (M20 and greater). Carbon steel hex nuts meeting the
mechanical property requirements of ASTM A563 Grade B (imperial - heavy hex nuts) and ASTM A563M Class 9
(metric - hex nuts). Track bolts and hex nuts are zinc electroplated per ASTM B633 FE/ZN5, finish Type III (imperial)
or Type II (metric).
Optional: Stainless steel oval neck track bolts or studs meeting the mechanical property requirements of ASTM
A193 Grade B8M, Class 2 (316 stainless steel). Stainless steel heavy hex nuts meeting the mechanical property
requirements of ASTM A194 Grade 8M (316 stainless steel) with galling reducing coating.
For 26 – 50"/DN650 – DN1250 sizes:
Washers: Plated carbon steel, flat. SAE high strength conforming to ASTM F436 or high strength stainless steel.
2 Optional bolts/nuts are available in imperial size only.

20.02 3852 Rev Q Updated 01/2019 © 2019 Victaulic Company. All rights reserved.

victaulic.com 2
victaulic.com

4.0 DIMENSIONS

Y Z
Y Z

X
X

Typical 14 – 24"/DN350 – DN600 Typical 26 – 50"/DN650 – DN1250 Exaggerated for clarity

Pipe End
Size Separation Bolt/Nut Dimensions Weight

Actual
Outside Approximate
Nominal Diameter Allowable Qty. Size X Y Z (Each)
inches inches inches inches inches inches lb
DN mm mm inches mm mm mm kg
14 14.000 0.25 15.88 20.63 4.75 49.0
2 1 x 5 1/2
DN350 355.6 6.4 403 524 121 22.2
14.843 0.25 16.78 21.41 4.80 51.3
2 M24 X 139.7
377.0 6.4 426 544 122 23.3
16 16.000 0.25 18.13 23.50 4.75 61.0
2 1 x 5 1/2
DN400 406.4 6.4 460 597 121 27.7
16.772 0.25 18.95 23.47 4.80 63.9
2 M24 X 139.7
426.0 6.4 481 596 122 29.0
18 18.000 0.25 20.25 25.50 4.75 71.0
2 1 x 5 1/2
DN450 457.0 6.4 514 648 121 32.2
18.898 0.25 21.18 25.72 4.80 74.2
2 M24 X 139.7
480.0 6.4 538 653 122 33.6
20 20.000 0.25 22.50 27.13 4.75 82.0
2 1 1⁄8 x 5 1/2
DN500 508.0 6.4 570 689 121 37.2
22 22.000 0.25 24.75 29.38 4.75 110.0
2 1 1⁄8 x 6
DN550 559.0 6.4 629 746 121 49.9
245 24.000 0.25 26.63 32.38 4.75 116.0
2 1 1⁄8 x 5 1/2
DN600 610.0 6.4 677 822 121 52.6
26 26.000 0.38 30.13 35.25 5.75 205.0
4 1 1⁄8 x 6
DN650 660.4 9.6 765 895 146 93.0
28 28.000 0.38 32.25 37.25 5.75 220.0
4 1 1⁄8 x 6
DN700 711.2 9.6 819 945 146 99.8
30 30.000 0.38 33.88 39.63 5.75 227.0
4 1 1/4 x 7
DN750 762.0 9.6 863 1007 146 103.0
32 32.000 0.38 36.13 41.75 5.75 242.0
4 1 1/4 x 7
DN800 812.8 9.6 917 1060 146 109.8
34 34.000 0.38 38.25 43.75 5.75 255.0
4 1 1/4 x 7
DN850 864.0 9.6 972 1161 146 115.7
36 36.000 0.38 40.25 45.75 5.75 268.0
4 1 1/4 x 7
DN900 914.4 9.6 1022 1161 146 121.6
38 38.000 0.38 41.25 48.00 5.75 304.0
4 1 1/4 x 7
DN950 965.0 9.6 1048 1219 146 138.2
40 40.000 0.44 44.00 50.50 6.50 340.0
4 1 1/2 x 8
DN1000 1016.0 11.1 1117 1283 165 154.2
NOTES
• WARNING: FOR ONE TIME FIELD TEST ONLY, the Maximum Joint Working Pressure may be increased to 11/2 times the figures shown.
• The allowable pipe end separation dimension shown is for system layout purposes only. Style W07 AGS rigid couplings are considered rigid connections and
will not accommodate expansion/contraction or angular movement of the piping system. Contact Victaulic for torsional resistance information.
• The outside diameter, ovality, and surface finish including flat spots and imperfections shall not vary more than the limits of API 5L end tolerance.
• Refer to publication 25.09 for proper groove specifications.
• Style W07 AGS couplings are essentially rigid and do not permit expansion/contraction.
• Additional wall thicknesses available. For performance on additional pipe wall thicknesses contact Victaulic.
• For additional pipe sizes, please contact Victaulic.

20.02 3852 Rev Q Updated 01/2019 © 2019 Victaulic Company. All rights reserved.

victaulic.com 3
victaulic.com

4.0 DIMENSIONS (Continued)

Y Z
Y Z

X
X

Typical 14 – 24"/DN350 – DN600 Typical 26 – 50"/DN650 – DN1250 Exaggerated for clarity

Pipe End
Size Separation Bolt/Nut Dimensions Weight

Actual
Outside Approximate
Nominal Diameter Allowable Qty. Size X Y Z (Each)
inches inches inches inches inches inches lb
DN mm mm inches mm mm mm kg
42 42.000 0.44 46.00 54.50 6.50 360.0
4 1 1/2 x 8
DN1050 1066.8 11.1 1168 1384 165 163.3
44 44.000 0.44 48.00 54.50 6.50 390.0
4 1 1/2 x 8
DN1100 1117.6 11.1 1219 1384 165 177.0
46 46.000 0.44 50.25 56.50 6.50 415.0
4 1 1/2 x 8
DN1150 1168.4 11.1 1277 1435 165 188.2
48 48.000 0.44 52.25 58.50 6.50 425.0
4 1 1/2 x 8
DN1200 1219.2 11.1 1328 1485 165 192.8
50 50.000 0.44 53.63 60.88 10.00 500.0
4 1 1/2 x 8
DN1250 1270.0 11.1 1362 1546 254 227.0
NOTES
• WARNING: FOR ONE TIME FIELD TEST ONLY, the Maximum Joint Working Pressure may be increased to 11/2 times the figures shown.
• The outside diameter, ovality, and surface finish including flat spots and imperfections shall not vary more than the limits of API 5L end tolerance.
• Style W07 AGS couplings are essentially rigid and do not permit expansion/contraction.
• Refer to publication 25.09: Victaulic Roll Groove Specifications for proper groove specifications.
• Additional wall thicknesses available. For performance on additional pipe wall thicknesses contact Victaulic.
• For additional pipe sizes, please contact Victaulic.

20.02 3852 Rev Q Updated 01/2019 © 2019 Victaulic Company. All rights reserved.

victaulic.com 4
victaulic.com

5.0 PERFORMANCE
Maximum Working
Size Pressure
Actual
Outside Light Extra Max. End
Nominal Diameter Wall4 Std.Wall Heavy Load3
inches inches psi psi 1/2– ¾" lb
DN mm kPa kPa 13–19mm N
14 14.000 350 350 350 55800
DN350 355.6 2400 2400 2400 248310
14.843 350 350 350 60562
377.0 2400 2400 2400 269393
16 16.000 350 350 350 72885
DN400 406.4 2400 2400 2400 324338
16.772 350 350 350 77326
426.0 2400 2400 2400 343963
18 18.000 350 350 350 92245
DN450 457.0 2400 2400 2400 410490
18.898 350 350 350 98172
480.0 2400 2400 2400 436691
20 20.000 350 350 350 113880
DN500 508.0 2400 2400 2400 506766
22 22.000 350 350 350 114000
DN550 559.0 2400 2400 2400 507080
245 24.000 225 350 350 163990
DN600 610.0 1600 2400 2400 729756
26 26.000 300 300 300 159279
DN650 660.4 2065 2065 2065 708508
28 28.000 300 300 300 184726
DN700 711.2 2065 2065 2065 821702
30 30.000 300 300 300 212058
DN750 762.0 2065 2065 2065 943281
32 32.000 300 300 300 241274
DN800 812.8 2065 2065 2065 1073240
34 34.000 300 300 300 305363
DN850 864.0 2065 2065 2065 1358322
36 36.000 300 300 300 305363
DN900 914.4 2065 2065 2065 1358322
38 38.000 300 300 300 340235
DN950 965.0 2065 2065 2065 1513365
40 40.000 300 300 300 376991
DN1000 1016.0 2065 2065 2065 1676940
42 42.000 300 300 300 415632
DN1050 1066.8 2065 2065 2065 1848823
44 44.000 232 232 232 352763
DN1100 1117.6 1600 1600 1600 1569168
46 46.000 232 232 232 385561
DN1150 1168.4 1600 1600 1600 1715746
48 48.000 232 232 232 419820
DN1200 1219.2 1600 1600 1600 1868199
50 50.000 232 232 232 4555530
DN1250 1270.0 1600 1600 1600 2026298
3 End loads are total from all internal and external loads, based on carbon steel pipe, rolled with Victaulic AGS rolls in accordance with publication 25.09:
Victaulic AGS Roll Groove Specifications. Contact Victaulic for performance on other pipe.
4 Light Wall for 14"/DN350 = 0.22"/5.6 mm; 16 – 24"/DN400 – DN600 = 0.25"/6.35 mm; 26 – 50"/DN650 – DN1250 = 0.312/7.9 mm
Light Wall for 377mm = 0.217"/5.5mm; 426mm = 0.256"/6.5mm; 480mm = 0.256"/6.5mm
5 The end load for 24"/DN600 installed on light wall pipe is 101790 lbs/456426 N.

20.02 3852 Rev Q Updated 01/2019 © 2019 Victaulic Company. All rights reserved.

victaulic.com 5
victaulic.com

5.1 PERFORMANCE
Torque Requirements

Nominal Pipe Size Required Torque


inches ft. lbs.
DN N•m
14, 16, 18 250
350, 400, 450 340
250
377,426, 480mm
340
20, 22, 24, 26, 28 375
500, 550, 600, 650, 700 500
30, 32, 34, 36, 38 500
750, 800, 850, 900, 950 680
40, 42, 44, 46, 48, 50 600
1000, 1050, 1100, 1150, 1200, 1250 813

6.0 NOTIFICATIONS

WARNING
• When grooving pipe for use with AGS products, Victaulic roll grooving tools must be equipped with AGS roll sets
(RW for steel or RWX for stainless steel).
• RWX grooving rolls are identified by a silver color and the designation "RWX" on the front of the roll sets.
• Victaulic AGS products MUST NOT be installed on pipe that is prepared with original-type grooving roll sets.
• To ensure proper pipe end preparation refer to publication 25.09 for AGS (Advanced Groove System) roll groove
pipe specifications.
Failure to follow these instructions will cause grooves that are not within Victaulic AGS specifications, resulting in
joint failure, serious personal injury, and property damage.

7.0 REFERENCE MATERIALS


02.06: Potable Water Approvals
05.01: Victaulic Seal Selection Guide
16.11: AGS Vic-Ring Systems
20.05: AGS Fittings
24.01: Pipe Preparation Tools
25.09: AGS Roll Groove Specifications
26.01: Victaulic Design Data
29.01: Terms and Conditions/Warranty
I-100: Field Installation Handbook
I-ENDCAP: Victaulic End Caps Installation Instructions

User Responsibility for Product Selection and Suitability Note


Each user bears final responsibility for making a determination as to the suitability of This product shall be manufactured by Victaulic or to Victaulic specifications. All products
Victaulic products for a particular end-use application, in accordance with industry to be installed in accordance with current Victaulic installation/assembly instructions.
standards and project specifications, and the applicable building codes and related Victaulic reserves the right to change product specifications, designs and standard
regulations as well as Victaulic performance, maintenance, safety, and warning equipment without notice and without incurring obligations.
instructions. Nothing in this or any other document, nor any verbal recommendation, Installation
advice, or opinion from any Victaulic employee, shall be deemed to alter, vary, supersede, Reference should always be made to the Victaulic installation handbook or installation
or waive any provision of Victaulic Company's standard conditions of sale, installation instructions of the product you are installing. Handbooks are included with each shipment
guide, or this disclaimer. of Victaulic products, providing complete installation and assembly data, and are available
Intellectual Property Rights in PDF format on our website at www.victaulic.com.
No statement contained herein concerning a possible or suggested use of any material, Warranty
product, service, or design is intended, or should be constructed, to grant any license Refer to the Warranty section of the current Price List or contact Victaulic for details.
under any patent or other intellectual property right of Victaulic or any of its subsidiaries
or affiliates covering such use or design, or as a recommendation for the use of such Trademarks
material, product, service, or design in the infringement of any patent or other intellectual Victaulic and all other Victaulic marks are the trademarks or registered trademarks of
property right. The terms “Patented” or “Patent Pending” refer to design or utility patents Victaulic Company, and/or its affiliated entities, in the U.S. and/or other countries.
or patent applications for articles and/or methods of use in the United States and/or other
countries.

20.02 3852 Rev Q Updated 01/2019 © 2019 Victaulic Company. All rights reserved.

victaulic.com 6

You might also like