Pt1000 Sensor in Enclosure: Item No.: 423.210, 423.303, 423.304

The PT1000 sensor measures ambient temperature through a PT1000 measuring resistance. It can connect directly to data loggers configured for resistance measurement. For long cable runs, a voltage converter should be used between the sensor and data logger configured for voltage measurement. The sensor has an operating temperature range of -35 to 90°C and IP65 protection in a 50x65x45.5mm enclosure with screw terminals.

Uploaded by

Solar Projects
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
168 views2 pages

Pt1000 Sensor in Enclosure: Item No.: 423.210, 423.303, 423.304

The PT1000 sensor measures ambient temperature through a PT1000 measuring resistance. It can connect directly to data loggers configured for resistance measurement. For long cable runs, a voltage converter should be used between the sensor and data logger configured for voltage measurement. The sensor has an operating temperature range of -35 to 90°C and IP65 protection in a 50x65x45.5mm enclosure with screw terminals.

Uploaded by

Solar Projects
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

PT1000 SENSOR IN

ENCLOSURE
Item No.: 423.210, 423.303, 423.304

DESCRIPTION OF FUNCTION The sensor measures the ambient temperature using a PT1000 measuring resistance.
The sensor can be connected directly to an analog input of every meteocontrol data logger. The
logger must be configured for resistance measurement.

To avoid deviations because of long cable length, a voltage converter (0 to 10 V), type PXT-11,
should be used. The converter is connected to an analog input of the data logger. The logger
must be configured for voltage measurement.

TECHNICAL DATA
PT1000 sensor in enclosure
Operating temperature: -35 … 90 °C
Protection class: IP65
Dimensions (W x H x D): 50 mm x 65 mm x 45.5 mm
Sensor type: PT1000
Connection terminal: Screw-type, max. 1.5 mm²

PT1000 signal converter 24 V DC


Item No.: 423.303
Inaccuracy: < 1 % from the measuring range, without scaling
Linearity: < 0,25 % full scale value
Temperature coefficient: < 0,02 %/°C
Power consumption: 2W
Displays: Green LED – supply voltage
Yellow LED – input signal 5 to 10 % of the maximum signal
Operating temperature: -20 to 55 °C

PT1000 signal converter 230 V AC


Item No.: 423.304
Inaccuracy: < 1 % from the measuring range, without scaling
Linearity: < 0,25 % full scale value
Temperature coefficient: < 0,02 %/°C
Power consumption: 3W
Insulation for supply: 3,75 kV, 1 min
Displays: Green LED – supply voltage
Yellow LED – input signal 5 to 10 % of the maximum signal
Operating temperature: -20 to 55 °C

Information subject to change, errors and omissions excepted / As at 12-2017 1/2


TEMPERATURE MEASUREMENT
Output signal: Electrical resistance, DIN EN 60751
Measuring range: Characteristic curve compliant with DIN EN 60751
Current consumption: < 1 mA

MEASUREMENT VALUES RECORDED


T_Ux* Ambient temperature

CONFIGURATION WHEN USING A


SIGNAL CONVERTER
Type: Voltage measurement
Gradient: 15
Offset: -50
Abbreviation: T_Ux*

PARTICULARITIES
*Abbreviation x is a placeholder for a consecutive number. If more than one sensor of a given type is installed,
the numbering starts with 1. Otherwise, 0 is used.

meteocontrol GmbH | Spicherer Straße 48 | 86157 Augsburg | Germany | Telephone +49 (0)821 34666 - 0 | Fax +49 (0)821 34666 - 11
E-Mail [email protected] | Web www.meteocontrol.com

Information subject to change, errors and omissions excepted / As at 12-2017 2/2