Data Sheet

Alcatel-Lucent
OmniSwitch 6865
Hardened Ethernet switches

The Alcatel-Lucent OmniSwitch 6865® is a family of ruggedized, advanced Layer 3, scalable


Ethernet switches, designed to operate reliably in the harshest industrial environments and
severe temperatures.

OS6865 switches are rugged, high access network, SPB-M for fast, cost-efficient
bandwidth switches that are ideal for roll-out of VPN services on the edge and
industrial and mission-critical applications a comprehensive suite of security features
that require wider operating temperature to secure the network edge. These
ranges, stringent EMC/EMI requirements switches are easy to deploy with Alcatel
and an optimized feature set for high Lucent’s award winning Intelligent-Fabric
OS6865-U12X security, reliability, performance and easy technology which offers out-of-the-box
management. These switches run on the plug-and-play, Zero-touch provisioning and
widely deployed and field-proven Alcatel- network automation. The OS6865 family
Lucent Operating system offering SPB-M offers advanced system and network level
based VPNs and other advanced routing resiliency features and convergence through
and switching capabilities. standardized protocols.

The OS6865 series offers a unique mix of These versatile industrial switches are
features to cater to the Hardened Ethernet ideal for deployment in transportation
OS6865-P16X
applications such as IEEE 1588v2 PTP and traffic control systems, power utilities,
capabilities for timing requirements of video surveillance systems and outdoor
industrial devices, HPoE for (75W PoE) installations.
for those power hungry devices on the

OS6865-U28X
FEATURES BENEFITS
• Resilient ruggedized hardware design • Operates at a wider temperature range from -40°C to +74°C, withstands greater
shock, vibrations, temperature and EMI/EMC variance
• Convection cooled fan-less models • Fan-less operations increases resiliency and maximizes uptime for converged
mission-critical networks
• Advanced Industrial PoE capabilities with • Enables converged deployments and is ideal for all type of PoE application
support for HPoE (75 W) requirements from outdoor wireless APs, to PTZ surveillance cameras and video
displays
• IEEE 1588v2 PTP support • Provides precise sub-microsecond time synchronization for slave devices
• SPB-M Support for Scalable network • Optimizes/simplifies Layer 2 and Layer 3 network designs and reduces
virtualization architecture over standard administration overhead
Ethernet fabric
• Virtual Chassis technology, to connect multiple • Increases system redundancy, resiliency and high availability while simplifying
switches to create a single chassis-like entity deployment, operations and management of the network
• Auto-fabric technology to simplify installation • Enables Zero-touch provisioning and network automation with auto- matic protocol
and service provisioning and topology discovery
• Prevent human mistakes by automating standardized and replicable configurations
• Built in resiliency & redundancy • Field upgradable, highly redundant network solution maximizes network uptime
• Hot-swappable, fully redundant power supplies
• Delivers redundant ring topologies using
industry standard protocols
• SDN Ready • The support of SDN allows creation of specialized services which ensures that your
¬¬ OpenFlow and OpenStack support investment is ready for the future and enables interoperability with third-party
¬¬ Supports RESTful APIs commands & MIBs solutions
¬¬ Embedded scripting capabilities • REST APIs provides access to all AOS CLI and with advanced embedded scripting
capabilities using Python and Bash, it enables fast deployment of new network
services and be able to continuously adopt new applications to support the
business

Alcatel-Lucent OmniSwitch 6865 All the models have built-in 10 Gigabit SFP+ OmniSwitch 6865 switches can form a
models ports that support 10 Gigabits and 1000-X, a Virtual Chassis between any models creating
USB port and a console port. a single chassis-like entity using 10G SFP+
The OmniSwitch 6865 offers customers
ports. Up to 8 switches can be connected
Gigabit fixed-configuration switches with
All the models of OS6865 family support 4 in a Virtual Chassis configuration OS6865-
up to 75 watts of PoE per port and power
ports of 75W PoE. OS6865-U28X model also U28X also has dedicated QSFP+ Virtual
supply options that accommodate the most
provides dedicated 20G Virtual chassis ports. Chassis ports in rear.
demanding requirements. The switches can
OS6865 switches offer a surge protection of
be mounted on wall/panel or a 19-inch rack.
6KV on all copper ports.

GIGABIT SFP PORTS 1G/10G SFP+ 75W HPOE/ DESCRIPTION


PORTS (RJ45) PORTS POE+ PORTS
OS6865-P16X 12 2 2 4/8 Fixed-configuration hardened fan-less half-rack width
2RU chassis with twelve 10/100/1000 Base-T PoE+
ports, four of which can support 75W HPoE, two 1000
Base-X SFP ports and two fixed SFP+ (1G/10G) ports
OS6865-U12X 4 6 2 4/- Fixed-configuration hardened fan-less half-rack width
2RU chassis with four 100/1000 Base-X SFP, two 1000
Base-X SFP, two fixed SFP+ (1G/10G) ports and four
10/100/1000 Base-T 75W HPoE ports.
OS6865-U28X 4 20 4 4/- Fixed-configuration hardened fan-less full-rack width
1RU chassis with twenty 100/1000 Base-X SFP, four
fixed SFP+ (1G/10G) ports, four 10/100/1000 Base-T
75W HPoE ports and two 20G VFL QSFP+ ports.

Alcatel-Lucent OmniSwitch 6865


ALCATEL-LUCENT ENTERPRISE DATA SHEET
2
Technical specifications
OmniSwitch 6865 models
PRODUCT MATRIX OS6865-P16X OS6865-U12X OS6865-U28X
Operating temperature* -40°C to 74°C -40°C to 74°C -40°C to 74°C
(-40°F to 165°F) (-40°F to 165°F) (-40°F to 165°F)
Fans 0 0 0
File system flash 2 GB 2 GB 2 GB
RAM 2 GB 2 GB 2 GB
Altitude 13,000 ft 13,000 ft 13,000 ft
Storage temperature -40°C to 85°C -40°C to 85°C -40°C to 85°C
(-40°F to 185°F) (-40°F to 185°F) (-40°F to 185°F)
Humidity (operating & storage) 5% to 95% non-condensing 5% to 95% non-condensing 5% to 95% non-condensing
USB port 1 1 1
Console port 1 1 1
Max raw fabric capacity 224 Gb/s 224 Gb/s 224 Gb/s
Switching capacity 68 Gb/s 60 Gb/s 208 Gb/s
Weight (no PS attached) 5.07 kg (11.18 lb) 5.17 Kg (11.40lb) 6.28 Kg (13.85 lbs)
Height 8.81 cm (3.47 in) 8.81 cm (3.47 in) 4.39cm (1.73 in)
Width 21.56 cm (8.49 in) 21.56 cm (8.49 in) 43.99 cm (17.32 in)
Depth (no PS attached) 26 cm (10.24 in) 26 cm (10.24 in) 27 cm (10.63 in)
1588v2 Capable Ports 16 12 28
20G QSFP+ VFL ports 0 0 2
Maximum PoE Budget** 300 W 300 W 280 W
Installation Options DIN/wall/panel, 19” rack DIN/wall/panel, 19” rack 19” rack
Power Consumption (idle)*** 30 W 29 W 49.6 W
Power Consumption (full load)*** 45 W 35.9 W 75.9 W
Heat Dissipation (BTU/hr)*** 102.3 98.9 170.6
Maximum surge protection on ports**** 6 KV 6 KV 6 KV
MTBF (with 1 AC power supply) 767,181 h 827, 848 h 709,199 h
MTBF (with 2 AC power supply) 1,044,414 h 1,141,692 h 952,763 h

* With airflow. In a sealed enclosure, without airflow, -40°C to +65 °C


** With 2 x AC or 2 x DC (48 V input) power supplies operating at -40°C to 60°C. Please refer to HW user’s guide for more information on PoE budget.
*** Power consumption measured at 120 VAC input. Full L2 traffic load measurement does not include PoE power consumption. Heat dissipation measured at idle:
1 watt ≈ 3.41214 BTU/h
**** On copper ports

Power supplies to provide extended PoE budgets. There can be connected with a cable (included) and
is no interruption of service when a new mounted independently using a Power tray.
OmniSwitch 6865 supports 1+1 redundant,
power supply is installed or an existing In a redundant configuration, power supplies
hot-swappable fan-less power supplies. It
one replaced. The power supplies can be can be installed in any manner AC+AC,
also supports power load-sharing between
installed directly at the back of the switch or AC+DC or DC+DC.
the primary and backup power supplies

PS MODELS OS6865-BP OS6865-BP-D


Description Modular AC power supply. Provides up Modular DC power supply. Provides up to 180 W
to 180 W of system & PoE power to one (48 V input)/140 W (24 V input) of system and
OS6865 switch PoE power to one OS6865 switch
Dimensions (H x W x L) 5.1 cm x 9.5 cm x 18.1 cm 5.1 cm x 9.5 cm x 18.1 cm
(2 in x 3.74 in x 7.12 in) (2 in x 3.74 in x 7.12 in)
Weight 1.42 Kg (3.14 lbs) 1.42 Kg (3.14 lbs)
Input voltage 100 VAC to 240 VAC -20 VDC to -72 VDC
Input Current 3A/100 V to 127 VAC 9A/-20 V to -28 VDC
1.5A/200 V to 240 VAC 6A/-36 V to -72 VDC
Max output power/current 180 W/3.22A 180 W/3.22A @ -36 to -72 VDC Input
140 W/2.5 A @ -20 to -28 VDC Input
Surge Protection 4 KV (Surge level 4) 4 KV (Surge level 4)
Fans 0 0

Alcatel-Lucent OmniSwitch 6865


ALCATEL-LUCENT ENTERPRISE DATA SHEET
3
Product specifications and Commercial EMI/EMC • EN 61000-4-17
measurements • 47 CRF FCC Part 15: 2015 Subpart B • EN 61000-4-29
(Class A) VCCI (Class A, with UTP Cables) • IEC 60255-5
Per-port LEDs
• ICES–003:2012 Issue 5, Class A • IEEE 1613
• Non-PoE ports - green: link/activity
• AS/NZS 3548 (Class A) – C-Tick Industry Specific Electric Power Substation
• PoE ports - amber: link/activity
• CE marking for European countries • IEEE 1613, Section 4 to 8
System LEDs (Class A) • IEC 61850-3
• OK: green/amber operational status of • CE Emission Railway Applications
the switch ¬ EN50581 (RoHS Recast) • EN 50121-4
• VC: green/amber master or slave role ¬ EN 55022 (EMI & EMC requirement) • EN 62236-4
in VC configuration. Number of blinks
¬ EN 55024 (Immunity Characteristics) • EN 61000-6-4
between each solid color state indicates
chassis-id ¬ EN 61000-3-2 (Harmonic Current Intelligent Transportation (Road)
emissions) • NEMA TS-2
• PS1: Green/Amber - status for the primary
power supply ¬ EN 61000-3-3 Marine*
• PS2: Green/Amber - status for the backup ¬ EN 61000-4-2 • DNV 2.4*
power supply ¬ EN 61000-4-3 • IEC 60945
¬ EN 61000-4-4 Federal certifications
Scalability numbers and speeds
• Wire rate at layer 2 and layer 3 on all ¬ EN 61000-4-5 (Surge Immunity, • FIPS 140-2
ports Class 4) • Common Criteria EAL2
• Virtual Fabric Link (VFL) ports raw ¬ EN 61000-4-6 • Common Criteria NDcPP
capacity: 42 Gb/s or 84 Gb/s aggregate ¬ EN 61000-4-8 • JITC
• Jumbo frame size: 9 216 bytes ¬ EN 61000-4-11 * In Process. Contact for availability
(for 1/10 Gb/s) IEEE802.3: Hi-pot Test
• Total number of MAC addresses: 48,000 (2.25 KV DC on all Ethernet Ports) Detailed product features
• Total number of IPv4 routes: 64,000 Industrial Simplified manageability and
• Number of VLANs: 4,000 Industrial Environmental configuration
• IEC 60870-2-2 (operational temperature) • Zero-touch provisioning and network
Virtual Chassis automation. Out-of-the box plug-and-play
• IEC 60068-2-1 (temperature type test
• Number of units in a VC: 2. Scalable up Auto-Fabric for automated discovery of
– cold)
to 8 in future. configuration server, topology & protocols
• IEC 60068-2-2 (temperature type test
• DAC cables for VC connection: 40 cm, and automated switch configuration.
– hot)
1m, 3m Works with any non-Alcatel-Lucent device
• IEC 60721-3-1: Class 1K5 (storage that supports Shortest Path Bridging-MAC,
Compliance and certifications temperature) SPBM), 802.1ak (MVRP), 802.3ad/802.1AX
• IEC 60068-2-30: 5% to 95% non- (Link Aggregation Control Protocol, LACP)
Commercial Safety
condensing humidity • Intuitive CLI in a scriptable Python & BASH
• UL 60950-1, 2nd Ed.
• IEC 60255-21-2 (mechanical shock) environment via console, Telnet or Secure
• IEC 60950-1; all national deviations and
• IEC 60255-21-1 (vibration) Shell (SSH) v2 over IPv4/IPv6
amendments
Industrial Safety • Powerful WebView Graphical Web
• EN 60950-1; all deviations
• UL 508 Interface via HTTP and HTTPS over
• CAN/CSA-C22.2 No. 60950-1-03 IPv4/IPv6
• UL 61010
• NOM-019 SCFI, Mexico • Fully programmable RESTful web services
• EN 50021
• AS/NZ TS-001 and 60950:2000, Australia interface with XML and JSON support.
• Hazardous Location
• UL-AR, Argentina API enables access to CLI and individual
¬ ISA 12.12.01/UL 1604 mib objects
• UL-GS Mark, Germany
¬ CSA22.2/213 • Supported by ProActive Lifecycle
• CU, EAC, Russia
• IP30 Manager (PALM) which quickly and
• ANATEL, Brazil
Industrial Emission easily generates an inventory list of
• CCC, China
• EN 61805-3 Alcatel-Lucent Enterprise Wi-Fi and LAN
• KCC Korea switching products on your network,
• EN 55032 (Emission Standard)
• BSMI, Taiwan provides status in terms of software
• EN 61000-3-2
• EN 60825-1 Laser lifecycle, hardware lifecycle, warranty,
• EN 61000-3-3 and support status. Current maintenance
• EN 60825-2 Laser
• EN 55024 (Immunity Standard) release, recommended replacement for
• CDRH Laser
• EN 61000-4-2 to EN 61000-4-8 EOL products, and latest release notes are
• RoHS & WEEE directives compliant available as well through an easy-to–use
• EN 61000-4-11
web interface
• EN 61000-4-12
• Integrated with Alcatel-Lucent OmniVista®
• EN 61000-4-16
products for network management

Alcatel-Lucent OmniSwitch 6865


ALCATEL-LUCENT ENTERPRISE DATA SHEET
4
• Full configuration and reporting using • Virtual Chassis In-Service Software authorization
SNMPv1/2/3 to facilitate third-party Upgrade (ISSU) • Learned Port Security (LPS) or MAC
network management over IPv4/IPv6 • Remote Virtual Chassis - Up to 10-km address lockdown
• Integrated with Nokia 5620 Service Aware fault-tolerant remote stacking supported • Access Control Lists (ACLs); flow-based
Manager (SAM) ® application for network • Smart continuous switching technology filtering in hardware (Layer 1 to Layer 4)
management.
• ITU-T G.8032/Y1344 2010: Ethernet Ring • DHCP Snooping, DHCP IP and Address
• File upload using USB, TFTP, FTP, SFTP or Protection Resolution Protocol (ARP) spoof protection
SCP using IPv4/IPv6
• IEEE 802.1s Multiple Spanning Tree • ARP poisoning detection
• Human-readable ASCII-based configuration Protocol (MSTP) encompasses IEEE 802.1D • IP Source Filtering as a protective and
files for off-line editing, bulk configuration Spanning Tree Protocol (STP) and IEEE effective mechanism against ARP attacks
and out-of-the-box auto-provisioning 802.1w Rapid Spanning Tree Protocol
• Bring Your Own Device (BYoD) provides
• Fully programmable OpenFlow 1.3.1 and (RSTP)
on-boarding of Guest, IT/non-IT issued and
1.0 agent for control of native OpenFlow • Per-VLAN spanning tree (PVST+) and 1x1 silent devices. Restriction/Remediation of
and hybrid ports STP mode traffic from non-compliant devices. Uses
• Non-volatile memory for start-up • IEEE 802.3ad/802.1AX Link Aggregation RADIUS CoA to dynamically enforce User
configuration Control Protocol (LACP) and static LAG Network Profiles based on Authentication,
• Multiple microcode image support with groups across modules Profiling, Posture check of devices.
fallback recovery • Dual-home link support for sub-second • Private VLAN
• Dynamic Host Configuration Protocol link protection without STP • LLDP Security mechanism for rogue device
(DHCP) relay for IPv4/IPv6 • Virtual Router Redundancy Protocol detection and restriction
• IEEE 802.1AB Link Layer Discover (VRRP) with tracking capabilities
Network Control
Protocol (LLDP) with Media Endpoint • IEEE protocol auto-discovery
• LGS CodeGuardian solution is available
Discover (MED) extensions
• Bidirectional Forwarding Detection (BFD) on OmniSwitch® 6865, hardening it at
• Network Time Protocol (NTP) for fast failure detection and reduced both the software source code and binary
• DHCPv4 and DHCPv6 server managed re-convergence times in a IPv4/IPv6 executable levels to enhance overall
by Nokia VitalQIP® DNS/DHCP IP Address routed environment network security.
Management • Redundant and hot-swappable power • CodeGuardian protects networks from
• Dynamic PoE allocation delivers only supplies intrinsic vulnerabilities, code exploits,
the power needed up to the total • Built-in CPU protection against malicious embedded malware, and potential back
power budget for most efficient power attacks doors that could compromise mission-
consumption critical operations.
• Split Virtual Chassis protection: Auto-
• Configurable per-port PoE priority, max detection and recovery of Virtual Chassis For additional information
power and time-of-day policy for PoE splitting due to one or more VFL or stack on CodeGuardian visit
power allocation element failures http://enterprise.alcatel-lucent.com
Monitoring and troubleshooting Advanced security QoS
• Local (on the flash) and remote server Access control • Priority queues: Eight hardware-based
logging (Syslog): event and command • Alcatel-Lucent Access Guardian framework queues per port for flexible QoS
logging for comprehensive user-policy-based NAC management
• IP tools: ping and trace route • Autosensing IEEE 802.1X multi-client, • Traffic prioritization: Flow-based QoS
• Dying Gasp support via SNMP and multi-VLAN support Flow-based traffic policing and bandwidth
syslog messages management
• MAC-based authentication for non-IEEE
• Loopback IP address support for 802.1X hosts • 32-bit IPv4/128-bit IPv6 non-contiguous
management per service mask classification
• Web based authentication (captive portal):
• Management virtual routing and a customizable web portal residing on the • Egress traffic shaping
forwarding (VRF) support switch • DiffServ architecture
• Policy- and port-based mirroring • User Network Profile (UNP) simplifies NAC • Congestion avoidance: Support for end-
• Remote port mirroring by dynamically providing pre-defined to-end head-of-line (E2E-HOL) blocking
• sFlow v5 and Remote Monitoring (RMON) policy configuration to authenticated prevention, IEEE 802.1Qbb Priority-based
clients — VLAN, ACL, BW Flow Control (PFC) and IEEE 802.3x Flow
• Unidirectional Link Detection (UDLD),
• Secure Shell (SSH) with public key Control (FC)
Digital Diagnostic Monitoring (DDM),
and Time Domain Reflectometry (TDR) infrastructure (PKI) support Layer-3 routing and multicast
• Terminal Access Controller Access-Control IPv4 routing
Resiliency and high availability System Plus (TACACS+) client • Multiple VRF & inter-VRF route leaking
• Unified management, control and virtual
• Centralized Remote Access Dial-In • Static routing
chassis technology
User Service (RADIUS) and Lightweight
• Virtual Chassis 1+N redundant supervisor • Routing Information Protocol (RIP) v1
Directory Access Protocol (LDAP)
manager and v2
administrator authentication
• Open Shortest Path First (OSPF) v2 with
• Centralized RADIUS for device
Graceful Restart
authentication and network access control

Alcatel-Lucent OmniSwitch 6865


ALCATEL-LUCENT ENTERPRISE DATA SHEET
5
• Intermediate System to Intermediate Advanced Layer-2 services ITU-T recommendations
System (IS-IS) with Graceful Restart • Ethernet services support using IEEE • ITU-T G.8032/Y.1344 2010: Ethernet Ring
• Border Gateway Protocol (BGP) v4 with 802.1ad Provider Bridges (also known as Protection (ERPv2)
Graceful Restart Q-in-Q or VLAN stacking)
IETF RFCs
• Generic Routing Encapsulation (GRE) and • Fabric virtualization services IEEE 802.1aq
IPv4
IP/IP tunneling Shortest Path Bridging (SPB-M)
• RFC 2003 IP/IP Tunneling
• Virtual Router Redundancy Protocol • Ethernet network-to-network interface
• RFC 2131 Dynamic Host Configuration
(VRRPv2) (NNI) and user network interface (UNI)
Protocol (DHCPv4)
• DHCP relay (including generic UDP relay) • Service Access Point (SAP) profile
• RFC 2784 GRE Tunneling
• Address Resolution Protocol (ARP) identification
• RFC 4022/2452 MIB for IPv4 TCP
• Policy-based routing and server load • Service VLAN (SVLAN) and Customer VLAN
(CVLAN) support • RFC 4087 IP Tunnel MIB
balancing
• VLAN translation and mapping including • RFC 4113/2454 MIB for IPv4 UDP
• DHCPv4 server
CVLAN to SVLAN • RFC 4292/4293 IPv4 MIBs
IPv6 routing
• Port mapping OSPF
• Multiple VRF & Inter-vrf route leaking
• DHCP Option 82: Configurable relay agent • RFC 1765 OSPF Database Overflow
• Internet Control Message Protocol
version 6 (ICMPv6) information • RFC 1850/2328/4570 OSPF v2 and MIB

• Static routing • Multiple VLAN Registration Protocol • RFC 2154 OSPF MD5 Signature
(MVRP) • RFC 2370/3630 OSPF Opaque LSA
• Routing Information Protocol Next
Generation (RIPng) • HA-VLAN for Layer 2 clusters such as • RFC 2740/5340 OSPFv3 for IPv6
MS-NLB and active-active Firewall clusters
• Open Shortest Path First (OSPF) v3 • RFC 3101 OSPF NSSA Option
with Graceful Restart • Jumbo frame support
• RFC 3623/5187 OSPF Graceful Restart
• Intermediate System to Intermediate • Bridge Protocol Data Unit (BPDU) blocking
• RFC 5838 MIB for OSPFv3
System (IS-IS) with Graceful Restart • STP Root Guard
•  RFC 4552 Authentication for OSPFv3
• Multi-Topology IS-IS (M-ISIS) • STP Loop-Guard
RIP
• BGP v4 multiprotocol extensions for • Loopback Detection to auto-detect and • RFC 1058 RIP v1
IPv6 routing (MP-BGP) prevent L2 loops
• RFC 1722/1723/2453/1724 RIP v2
• Graceful Restart extensions for OSPF and MIB
and BGP
Supported standards
• RFC 1812/2644 IPv4 Router Requirements
• Virtual Router Redundancy Protocol IEEE standards • RFC 2080 RIPng for IPv6
version 3 (VRRPv3) • IEEE 802.1D STP
BGP
• Neighbor Discovery Protocol (NDP) • IEEE 802.1p CoS
• RFC 1269/1657/4273 BGP v3 and v4 MIB
• Policy-based routing and server load • IEEE 802.1Q VLANs
• RFC 1403/1745 BGP/OSPF Interaction
balancing • IEEE 802.1ab (LLDP)
• RFC 1771-1774/2842/2918/3392/4271
• DHCPv6 server • IEEE 802.1ag (OA&M) BGP v4
• DHCPv6 Relay Agent • IEEE 802.1ad Provider Bridges Q-in-Q/ • RFC 1965 BGP AS Confederations
IPv4/IPv6 multicast VLAN stacking
• RFC 1966/2796 BGP Route Reflection
• Internet Group Management Protocol • IEEE 802.1ak (Multiple VLAN Registration
• RFC 1997/1998/4360 BGP
(IGMP) v1/v2/v3 snooping Protocol (MVRP)
Communities Attribute
• Protocol Independent Multicast – Sparse- • IEEE 802.1aq Shortest Path Bridging (SPB)
Mode (PIM-SM), Source Specific Multicast • RFC 2042/5396 BGP New Attribute
• IEEE 802.1s MSTP
(PIM-SSM) • RFC 2385 BGP MD5 Signature
• IEEE 802.3i 10BASE-T
• Protocol Independent Multicast – Dense- • RFC 2439 BGP Route Flap Damping
• IEEE 802.1w RSTP
Mode (PIM-DM), Bidirectional Protocol • RFC 2545 BGP-4 Multiprotocol Extensions
Independent Multicast (PIM-BiDir) • IEEE 802.3x Flow Control for IPv6 Routing
• Distance Vector Multicast Routing Protocol • IEEE 802.3z Gigabit Ethernet • RFC 2858/4760 Multiprotocol Extensions
(DVMRP) • IEEE 802.3ab 1000Base-T for BGP-4
• Multicast Listener Discovery (MLD) v1/v2 • IEEE 802.3ac VLAN Tagging • RFC 3065 BGP AS Confederations
snooping • IEEE 802.3ad/802.1AX Link Aggregation • RFC 4456 BGP Route Reflection
• PIM to DVMRP gateway support • IEEE 802.3ae 10 GigE • RFC 4486 Subcodes for BGP Cease
Fluent network for voice, video • IEEE 802.3af Power over Ethernet Notification
and data • IEEE 802.3at PoE Plus • RFC 4724 Graceful Restart for BGP
• SIP profile for QOS, priority tuning for • IEEE 802.3az Energy Efficient Ethernet (EEE) • RFC 3392/5492/5668/6793 BGP 4-Octet
end-to-end processing* • IEEE 802.1x-2004 ASN
• Multicast DNS Relay: Bonjour protocol • IEEE 1588-2008 (PTP) • RFC 5082 Generalized TTL Security
support for wired Airgroup Mechanism (GTSM)

Alcatel-Lucent OmniSwitch 6865


ALCATEL-LUCENT ENTERPRISE DATA SHEET
6
IS-IS • RFC 4113/2454 MIB for IPv6 UDP • RFC 4252 The Secure Shell (SSH)
• RFC 1142/1195/3719/3787/5308 IS-IS v4 • RFC 4193 Unique Local Addresses Authentication Protocol
• RFC 2763/2966/3567/3373 Adjacencies • RFC 4213/2893 Transition Mechanisms • RFC 4253 SSH Transport Layer Protocol
and route management • RFC 4291/3513/2373 Addressing • RFC 4254 SSH Connection Protocol
• RFC 5120 M-ISIS: Multi Topology IS-IS Architecture (uni/any/multicast) • RFC 4627 JavaScript Object Notation (JSON)
• RFC 5306 Graceful Restart • RFC 4292/4293 IPv6 MIBs • RFC 6585 Additional HTTP Status Codes
• RFC 5309/draft-ietf-isis-igp-p2p-over-lan • RFC 4301/2401 Security Architecture Security
Point to point over LAN • RFC 4302/2402 IP Authentication Header • RFC 1321 MD5
• RFC 6329 IS-IS Extensions Supporting IEEE • RFC 4303/2406 IP Encapsulating Security • RFC 1826/1827/4303/4305 Encapsulating
802.1aq SPB Payload (ESP) Payload (ESP) and crypto algorithms
•  RFC 5304 IS-IS Cryptographic Authentication • RFC 4308 Cryptographic Suites for IPSec • RFC 2104 HMAC Message Authentication
•  RFC 5310 IS-IS Generic Cryptographic • RFC 4443/2463 ICMPv6 • RFC 2138/2865/2868/3575/2618 RADIUS
Authentication Authentication and Client MIB
• RFC 4861/2461 Neighbor Discovery
IP Multicast • RFC 3576 Dynamic Authorization
• RFC 4862/2462 Stateless Address
• RFC 1075/draft-ietf-idmr-dvmrp-v3-11. Extensions to RADIUS
Autoconfiguration
txt DVMRP • RFC 2139/2866/2867/2620 RADIUS
• RFC 5095 Deprecation of Type 0 Routing
• RFC 2362/4601/5059 PIM-SM Accounting and Client MIB
Headers in IPv6
• RFC 2365 Multicast • RFC 2228 FTP Security Extensions
Manageability
• RFC 2710/3019/3810/MLD v2 for IPv6 • RFC 854/855 Telnet and Telnet options • RFC 2284 PPP EAP
• RFC 2715 PIM and DVMRP interoperability • RFC 959/2640 FTP • RFC 2869/2869bis RADIUS Extension
• RFC 2933 IGMP MIB • RFC 1350 TFTP Protocol • RFC 3162 RADIUS and IPv6
• RFC 3376 IGMPv3 (includes IGMP v2/v1) • RFC 1155/2578-2580 SMI v1 and SMI v2 • RFC 4301 Security Architecture for IP
• RFC 3569 Source-Specific Multicast (SSM) • RFC 1157/2271 SNMP • RFC 5517 Private VLAN
• RFC 3973 Protocol Independent Multicast- • RFC 1212/2737 MIB and MIB-II Security - With Common Criteria enabled
Dense Mode (PIM-DM) • RFC 5280 - Internet X.509 PKI Certificate
• RFC 1213/2011-2013 SNMP v2 MIB
• RFC 4541 Considerations for IGMP and and CRL Profile
• RFC 1215 Convention for SNMP Traps
MLD Snooping Switches • RFC 2560 - X.509 Internet PKI Online
• RFC 1573/2233/2863 Private Interface
• RFC 5015 BiDIR PIM Certificate Status Protocol - OCSP
MIB
• RFC 5060 Protocol Independent Multicast MIB • RFC 2986 - PKCS #10: Certification
• RFC 1643/2665 Ethernet MIB
• RFC 5132 Multicast Routing MIB Request Syntax Specification v 1.7
• RFC 1867 Form-based File Upload in
• RFC 5240 PIM Bootstrap Router MIB • RFC 5246 - TLS Protocol v 1.2
HTML
IPv6 • RFC 4346 - TLS Protocol v 1.1
• RFC 1901-1908/3416-3418 SNMP v2c
• RFC 1981 Path MTU Discovery • RFC 3268 - AES Cipher suites for TLS
• RFC 2096 IP MIB
• RFC 2460 IPv6 Specification • RFC 6125 - Representation and
• RFC 2131 DHCP Server/Client
• RFC 2461 NDP Verification of Domain-Based Application
• RFC 2388 Returning Values from Forms: Service Identity within Internet PKIX
• RFC 2464 IPv6 over Ethernet multipart/form-data Certificates in the Context of TLS
• RFC 2465 MIB for IPv6: Textual • RFC 2396 Uniform Resource Identifiers • draft-ietf-radext-radsec-12 - TLS
Conventions (TC) and General Group (URI): Generic Syntax encryption for RADIUS
• RFC 2466 MIB for IPv6: ICMPv6 Group • RFC 2570-2576/3410-3415/3584 QoS
• RFC 2711 Router Alert Option SNMP v3
• RFC 896 Congestion Control
• RFC 3056 6to4 Tunnels • RFC 2616 /2854 HTTP and HTML
• RFC 1122 Internet Hosts
• RFC 3315 Dynamic Host Configuration • RFC 2667 IP Tunneling MIB
• RFC 2474/2475/2597/3168/3246
Protocol for IPv6 (DHCPv6) • RFC 2668/3636 IEEE 802.3 MAU MIB DiffServ
• RFC 3484 Default Address Selection • RFC 2674 VLAN MIB • RFC 2697 srTCM
• RFC 3493/2553 Basic Socket API • RFC 3023 XML Media Types • RFC 2698 trTCM
• RFC 3542/2292 Advanced Sockets API • RFC 3414 User-based Security Model • RFC 3635 Pause Control
• RFC 3587/2374 Global Unicast Address • RFC 3826 (AES) Cipher Algorithm in the Others
Format SNMP User-based Security Model • RFC 791/894/1024/1349 IP and IP
• RFC 3595 TC for IPv6 Flow Label • RFC 4122 A Universally Unique IDentifier Ethernet
• RFC 3596/1886 DNS for IPv6 (UUID) URN Namespace • RFC 792 ICMP
• RFC 4007 Scoped Address • RFC 4234 Augmented BNF for Syntax • RFC 768 UDP
• RFC 4022/2452 MIB for IPv6 TCP Specifications: ABNF
• RFC 793/1156 TCP/IP and MIB
• RFC 4087 IP Tunnel MIB • RFC 4251 Secure Shell Protocol Architecture
•  RFC 2581 TCP Congestion Control

Alcatel-Lucent OmniSwitch 6865


ALCATEL-LUCENT ENTERPRISE DATA SHEET
7
• RFC 826 ARP • RFC 1305/2030 NTP v3 and Simple NTP • RFC 2338/3768/2787 VRRP and MIB
• RFC 919/922 Broadcasting Internet • RFC 1493 Bridge MIB • RFC 3021 Using 31-bit Prefixes
Datagram • RFC 1518/1519 CIDR • RFC 3060 Policy Core
• RFC 925/1027 Multi-LAN ARP/Proxy ARP • RFC 1541/1542/2131/3396/3442 DHCP • RFC 3176 sFlow
• RFC 950 Subnetting • RFC 1757/2819 RMON and MIB • RGC 3621 Power Ethernet MIB
• RFC 951 BOOTP •  RFC 2581 TCP Congestion Control Software Defined Networking (SDN)
• RFC 1151 RDP • RFC 2131/3046 DHCP/BootP Relay • OpenFlow Switch Specification v1.3.1
• RFC 1191 Path MTU Discovery • RFC 2132 DHCP Options • OpenFlow Switch Specification v1.0.0
• RFC 1256 ICMP Router RADIUS Discovery • RFC 2251 LDAP v3

Ordering information
PART NUMBER DESCRIPTION
OmniSwitch 6865 models
OS6865-P16X OS6865-P16X: Hardened Gigabit Ethernet L3 fixed configuration fan-less chassis with 12 RJ-45 10/100/1000
Base-T PoE+ ports out of which 4 are 75W HPoE ports, two 1000 Base-X SFP ports, two SFP+ (1G/10G) ports,
RS-232 Console (RJ45) and USB port. The bundle includes the chassis pre-installed with fully featured AOS software
& advanced IP routing SW (IPv4/IPv6), one AC power supply, country-specific power cord, user manuals access card,
power supply tray and hardware for mounting in a 19” rack
OS6865-P16XD OS6865-P16XD: Hardened Gigabit Ethernet L3 fixed configuration fan-less chassis with 12 RJ-45 10/100/1000
Base-T PoE+ ports out of which 4 are 75W HPoE ports, 2 1000 Base-X SFP ports, 2 SFP+ (1G/10G) ports, RS-232
Console (RJ45) and USB port. The bundle includes the chassis pre-installed with fully featured AOS software &
advanced IP routing SW (IPv4/IPv6), one DC power supply, user manuals access card, power tray and hardware for
mounting in a 19” rack
OS6865-U12X OS6865-U12X: Hardened Gigabit Ethernet L3 fixed configuration fan-less chassis with four 100/1000 Base-X SFP
ports, two 1000 Base-X SFP Ports, four 10/100/1000 Base-T 75W HPoE ports, two SFP+ (1G/10G) ports, RS-232
Console (RJ45) and USB port. The bundle includes the chassis pre-installed with fully featured AOS software &
advanced IP routing SW (IPv4/IPv6), one AC power supply, country-specific power cord, user manuals access card,
power tray and hardware for mounting in a 19” rack.
OS6865-U12XD OS6865-U12XD: Hardened Gigabit Ethernet L3 fixed configuration fan-less chassis with four 100/1000 Base-X SFP
ports, two 1000 Base-X SFP ports, four 10/100/1000 Base-T 75W HPoE ports, two SFP+ (1G/10G) ports, RS-232
Console (RJ45) and USB port. The bundle includes the chassis pre-installed with fully featured AOS software &
advanced IP routing SW (IPv4/IPv6), one DC power supply, user manuals access card, power tray and hardware for
mounting in a 19” rack.
OS6865-U28X OS6865-U28X: Hardened Gigabit Ethernet L3 fixed configuration fan-less chassis in a 1U form factor with 20
100/1000 Base-X SFP ports, four SFP+ (1G/10G) ports, four 10/100/1000 Base-T 75W HPoE ports, RS-232 Console
(RJ45), USB, and two 20G VFL QSFP+ ports. The bundle includes the chassis pre-installed with fully featured AOS
software & advanced IP routing SW (IPv4/IPv6), one AC power supply, country-specific power cord, user manuals
access card, power tray and hardware for mounting in a 19” rack.
OS6865-U28XD OS6865-U28XD: Hardened Gigabit Ethernet L3 fixed configuration fan-less chassis in a 1U form factor with 20
100/1000 Base-X SFP ports, four SFP+ (1G/10G) ports, four 10/100/1000 Base-T 75W HPoE ports, RS-232 Console
(RJ45), USB, and two 20G VFL QSFP+ ports. The bundle includes the chassis pre-installed with fully featured AOS
software & advanced IP routing SW (IPv4/IPv6), one DC power supply, user manuals access card, power tray and
hardware for mounting in a 19” rack.
OmniSwitch 6865 power supplies
OS6865-BP OS6865-BP modular AC backup power supply. Provides system & PoE power to one OS6865 switch. Ships with
country specific power cord
OS6865-BP-D OS6865-BP modular DC backup power supply. Provides system & PoE power to one OS6865 switch
OmniSwitch 6865 accessories
OS6865-CBL-40 OS6865 20 Gigabit direct attached copper cable (40 cm, QSFP+) for Virtual Chassis connections, for OS6865-U28X
OS6865-CBL-100 OS6865 20 Gigabit direct attached copper cable (1m, QSFP+) for Virtual Chassis connections, for OS6865-U28X
OS6865-CBL-300 OS6865 20 Gigabit direct attached copper cable (3m, QSFP+) for Virtual Chassis connections, for OS6865-U28X
OS6865-TRAY-1U Spare Power Supply tray kit with 1RU brackets for mounting two PS trays side-by-side in a 19” rack for
OS6865-U28X
OS6865-DIN-MNT DIN rail mounting kit for OS6865-P16X & OS6865-U12X switches. Includes universal mounting brackets and 2
brackets with DIN clip attached.
OS6865-REAR-MNT Mounting bracket & Side mounting rails kit to secure OS6865-U28x with the rear of a 19” rack

Alcatel-Lucent OmniSwitch 6865


ALCATEL-LUCENT ENTERPRISE DATA SHEET
8
PART NUMBER DESCRIPTION
OmniSwitch 6865 transceivers
iSFP-100-MM 100Base-FX industrial transceiver with an LC type interface. This transceiver is designed for use over multimode
fiber.
iSFP-100-SM15 100Base-FX industrial transceiver with an LC type interface. This transceiver is designed for use over single-mode
fiber up to 15 km
iSFP-100-LC-SM40 100Base-FX Industrial SFP transceiver with an LC type interface. This transceiver is designed for use over single
mode fiber optic cable up to 40KM.
iSFP-GIG-T 1000Base-T industrial Gigabit Ethernet Transceiver (SFP MSA). SFP works at 1000 Mb/s speed and full-duplex mode
iSFP-GIG-SX 1000Base-SX industrial Gigabit Ethernet industrial optical transceiver (SFP MSA)
iSFP-GIG-LX 1000Base-LX industrial Gigabit Ethernet optical transceiver (SFP MSA)
iSFP-GIG-LH40 1000Base-LH industrial Gigabit Ethernet optical transceiver (SFP MSA). Typical reach of 40 km on 9/125 µm SMF
iSFP-GIG-LH70 1000Base-LH industrial Gigabit Ethernet optical transceiver (SFP MSA). Typical reach of 70 km on 9/125 µm SMF
iSFP-GIG-BX-U 1000Base-BX SFP bi-directional transceiver with an LC type of interface. Designed for use over single mode fiber
optic on a single strand link up to 10 km. Transmits 1310 nm and receives 1490 nm optical signal.
iSFP-GIG-BX-D 1000Base-BX SFP bi-directional transceiver with an LC type of interface. Designed for use over single mode fiber
optic on a single strand link up to 10 km. Transmits 1310 nm and receives 1490 nm optical signal.
10G transceivers
iSFP-10G-LR 10 Gigabit industrial optical transceiver (SFP+). Supports monomode fiber over 1310 nm wavelength (nominal) with
an LC connector. Typical reach of 10 km
iSFP-10G-ER 10 Gigabit industrial optical transceiver (SFP+). Supports monomode fiber over 1550 nm wavelength (nominal) with
an LC connector. Typical reach of 40 km
SFP+ direct attached cables
iSFP-10G-C1M 10 Gigabit industrial direct attached copper cable (1 m, SFP+)
iSFP-10G-C3M 10 Gigabit industrial direct attached copper cable (3 m, SFP+)
iSFP-10G-C7M 10 Gigabit industrial direct attached copper cable (7 m, SFP+)

Warranty
The OmniSwitch 6865 family comes with a Limited Lifetime Warranty.

Services and support


For more information about our Professional services, Support services, and Managed services, please go to
http://enterprise.alcatel-lucent.com/?services=EnterpriseServices&page=directory.

www.al-enterprise.com Alcatel-Lucent and the Alcatel-Lucent Enterprise logo are trademarks of Alcatel-Lucent. To view other trademarks
used by affiliated companies of ALE Holding, visit: www.al-enterprise.com/en/legal/trademarks-copyright. All other trademarks are the
property of their respective owners. The information presented is subject to change without notice. Neither ALE Holding nor any of its
affiliates assumes any responsibility for inaccuracies contained herein. © 2017 ALE International. All rights reserved. 201704200002en
(November 2017)

You might also like