Primary-switched TRIO POWER power supply with push-in connection for DIN rail mounting, input: single
phase, output: 48 V DC/10 A

Product Description
TRIO POWER power supplies with standard functionality
The TRIO POWER power supply range with push-in connection has been perfected for use in machine building. All functions and the space-saving
design of the single and three-phase modules are optimally tailored to the stringent requirements. Under challenging ambient conditions, the power
supply units, which feature an extremely robust electrical and mechanical design, ensure the reliable supply of all loads.

Your advantages
 Save time and costs, thanks to the Push-in connection and narrow design
 Increase system availability, thanks to dynamic boost with 150% of the nominal current for five seconds
 Maximum flexibility due to the wide temperature range from -25°C to +70°C and device startup at -40°C
 Electrically robust, thanks to high electric strength
 Mechanically robust, thanks to high vibration and shock resistance

Key Commercial Data


Packing unit 1 pc

GTIN

GTIN 4055626255415

Technical data
Dimensions
Width 68 mm
Height 130 mm
Depth 160 mm
Installation distance right/left 0 mm / 0 mm
Installation distance top/bottom 50 mm / 50 mm

Ambient conditions
Degree of protection IP20
08/31/2021   Page 1 / 7
https://www.phoenixcontact.com/pi/products/2903160

Power supply unit - TRIO-PS-2G/1AC/48DC/10 - 2903160


Technical data
Ambient conditions
Inflammability class in acc. with UL 94 (housing / terminal blocks) V0
Ambient temperature (operation) -25 °C ... 70 °C (> 60 °C Derating: 2.5 %/K)
Ambient temperature (start-up type tested) -40 °C
Ambient temperature (storage/transport) -40 °C ... 85 °C
Max. permissible relative humidity (operation) ≤ 95 % (at 25 °C, non-condensing)
Climatic class 3K3 (in acc. with EN 60721)
Degree of pollution 2
Installation height ≤ 5000 m (> 2000 m, Derating: 10 %/1000 m)

Input data
Nominal input voltage range 100 V AC ... 240 V AC
110 V DC ... 250 V DC
Input voltage range 100 V AC ... 240 V AC -15 % ... +10 %
99 V DC ... 275 V DC
Dielectric strength maximum ≤ 300 V AC 15 s
AC frequency range 50 Hz ... 60 Hz ±10 %
Discharge current to PE < 3.5 mA
Current consumption 5.6 A (100 V AC)
5.4 A (120 V AC)
2.6 A (230 V AC)
2.4 A (240 V AC)
Nominal power consumption 604.7 VA
Inrush current 20 A (at 25 °C)
Mains buffering time typ. 10 ms (120 V AC)
typ. 15 ms (230 V AC)
Input fuse 10 A (internal (device protection))
Recommended breaker for input protection 10 A ... 16 A (Characteristics B, C, D, K)
Power factor (cos phi) 0.85
Type of protection Transient surge protection
Protective circuit/component Varistor

Output data
Nominal output voltage 48 V DC ±1 %
Setting range of the output voltage (USet) 36 V DC ... 55 V DC (> 48 V DC, constant capacity restricted)
Nominal output current (IN) 10 A
Dynamic Boost (IDyn.Boost) 15 A (5 s)
Derating > 60 °C ... 70 °C (2.5%/K)
Connection in parallel yes, for redundancy and increased capacity
Connection in series yes
Feedback voltage resistance ≤ 60 V DC
Protection against overvoltage at the output (OVP) ≤ 60 V DC
Control deviation < 1 % (change in load, static 10 % ... 90 %)
08/31/2021   Page 2 / 7
https://www.phoenixcontact.com/pi/products/2903160

Power supply unit - TRIO-PS-2G/1AC/48DC/10 - 2903160


Technical data
Output data
< 3 % (Dynamic load change 10 % ... 90 %, 10 Hz)
< 0.1 % (change in input voltage ±10 %)
Residual ripple < 50 mVPP (with nominal values)
Output power 480 W
Typical response time <1s
Peak switching voltages nominal load < 1000 mVPP
Maximum power dissipation in no-load condition < 5.7 W (230 V)
Power loss nominal load max. < 44 W

General
Net weight 1.4 kg
Efficiency > 93 % (for 230 V AC and nominal values)
MTBF (IEC 61709, SN 29500) > 1800000 h (25 °C)
> 800000 h (40 °C)
> 480000 h (60 °C)
Insulation voltage input/output 3 kV AC
1.5 kV AC
Degree of protection IP20
Protection class I (in closed control cabinet)
Inflammability class in acc. with UL 94 (housing / terminal blocks) V0
Mounting position horizontal DIN rail NS 35, EN 60715
Assembly instructions alignable: horizontally 0 mm (≤ 40 °C) 10 mm (≤ 70 °C), vertically 50 mm

Connection data, input


Connection method Push-in connection
Conductor cross section solid min. 0.2 mm²
Conductor cross section solid max. 4 mm²
Conductor cross section flexible min. 0.2 mm²
Conductor cross section flexible max. 2.5 mm²
Conductor cross section AWG min. 24
Conductor cross section AWG max. 12
Stripping length 10 mm

Connection data, output


Connection method Push-in connection
Conductor cross section solid min. 0.2 mm²
Conductor cross section solid max. 10 mm²
Conductor cross section flexible min. 0.2 mm²
Conductor cross section flexible max. 6 mm²
Conductor cross section AWG min. 24
Conductor cross section AWG max. 8
Stripping length 15 mm

08/31/2021   Page 3 / 7
https://www.phoenixcontact.com/pi/products/2903160

Power supply unit - TRIO-PS-2G/1AC/48DC/10 - 2903160


Technical data
Connection data for signaling
Connection method Push-in connection
Conductor cross section solid min. 0.2 mm²
Conductor cross section solid max. 1.5 mm²
Conductor cross section flexible min. 0.2 mm²
Conductor cross section flexible max. 1.5 mm²
Conductor cross section AWG min. 24
Conductor cross section AWG max. 16
Stripping length 8 mm

Standards
EMC requirements for noise immunity EN 61000-6-1
EN 61000-6-2
EMC requirements for noise emission EN 61000-6-3
EN 61000-6-4
Standard - Safety of transformers EN 61558-2-16 (air clearances and creepage distances only)
Standard - Electrical safety IEC 62368-1 (SELV)
Standard – Electronic equipment for use in electrical power installations
EN 50178/VDE 0160 (PELV)
and their assembly into electrical power installations
Standard – Safety extra-low voltage IEC 60950-1 (SELV) and EN 60204-1 (PELV)
Standard - Safe isolation DIN VDE 0100-410
Standard – Limitation of mains harmonic currents EN 61000-3-2
Rail applications EN 50121-4

Conformance/approvals
UL approvals UL Listed UL 508
UL/C-UL Recognized UL 60950-1

EMC data
Electromagnetic compatibility Conformance with EMC Directive 2014/30/EU
Low Voltage Directive Conformance with Low Voltage Directive 2014/35/EC
Electrostatic discharge EN 61000-4-2
Contact discharge 6 kV (Test Level 4)
Discharge in air 8 kV (Test Level 4)
Electromagnetic HF field EN 61000-4-3
Frequency range 80 MHz ... 1 GHz
Test field strength 10 V/m (Test Level 3)
Frequency range 1 GHz ... 2 GHz
Test field strength 10 V/m (Test Level 3)
Frequency range 2 GHz ... 3 GHz
Test field strength 10 V/m (Test Level 3)
Comments Criterion A
Fast transients (burst) EN 61000-4-4
Input 4 kV (Test Level 4 - asymmetrical)
08/31/2021   Page 4 / 7
https://www.phoenixcontact.com/pi/products/2903160

Power supply unit - TRIO-PS-2G/1AC/48DC/10 - 2903160


Technical data
EMC data
Output 2 kV (Test Level 3 - asymmetrical)
Signal 1 kV (Test Level 2 - asymmetrical)
Comments Criterion A
Surge voltage load (surge) EN 61000-4-5
Input 3 kV (Test Level 3 - symmetrical)
6 kV (Test Level 4 - asymmetrical)
Output 1 kV (Test Level 2 - symmetrical)
2 kV (Test Level 1 - asymmetrical)
Signal 1 kV (Test Level 2 - asymmetrical)
Comments Criterion B
Conducted interference EN 61000-4-6
I/O/S asymmetrical
Frequency range 0.15 MHz ... 80 MHz
Voltage 10 V (Test Level 3)
Comments Criterion A
Criterion A Normal operating behavior within the specified limits.
Temporary impairment to operational behavior that is corrected by the
Criterion B
device itself.

Environmental Product Compliance


REACh SVHC Lead 7439-92-1
China RoHS Environmentally Friendly Use Period = 25;
For details about hazardous substances go to tab “Downloads”,
Category “Manufacturer's declaration”

Drawings

Block diagram

+
L/+ +
active
N/- PFC -
-
-

13
14

Classifications
eCl@ss

eCl@ss 10.0.1 27040701


eCl@ss 11.0 27040701
eCl@ss 4.0 27040702
eCl@ss 4.1 27040702
eCl@ss 5.0 27049002
08/31/2021   Page 5 / 7
https://www.phoenixcontact.com/pi/products/2903160

Power supply unit - TRIO-PS-2G/1AC/48DC/10 - 2903160


Classifications
eCl@ss
eCl@ss 5.1 27049002
eCl@ss 6.0 27049000
eCl@ss 7.0 27049002
eCl@ss 9.0 27040701

ETIM

ETIM 4.0 EC002540


ETIM 6.0 EC002540
ETIM 7.0 EC002540

UNSPSC

UNSPSC 13.2 39121004


UNSPSC 18.0 39121004
UNSPSC 19.0 39121004
UNSPSC 20.0 39121004
UNSPSC 21.0 39121004

Accessories
Accessories
Device protection

Type 3 surge protection device - PLT-SEC-T3-230-FM-PT - 2907928

Type 2/3 surge protection, consisting of protective plug and base element with Push-in connection. For single-phase
power supply network with integrated status indicator and remote signaling. Nominal voltage: 230 V AC/DC
 
 

Type 3 surge protection device - PLT-SEC-T3-60-FM-PT - 2907926

Type 3 surge protection, consisting of protective plug and base element, with integrated status indicator and remote
signaling for single-phase power supply networks. Nominal voltage: 60 V AC/DC
 
 

Potential distributor

08/31/2021   Page 6 / 7
https://www.phoenixcontact.com/pi/products/2903160

Power supply unit - TRIO-PS-2G/1AC/48DC/10 - 2903160


Accessories

Potential distributors - VIP-2/SC/PDM-2/24 - 2315269

VARIOFACE module, with two equipotential busbars (P1, P2) for potential distribution, for mounting on NS 35 rails.
Module width: 70.4 mm
 
 

Potential distributors - VIP-3/PT/PDM-2/24 - 2903798

VARIOFACE module with push-in connection and two equipotential busbars (P1, P2) for potential distribution, for
mounting on NS 35 rails. Module width: 57.1 mm
 
 

Redundancy module

Redundancy module - TRIO-DIODE/48DC/2X10/1X20 - 2866527

Redundancy module with function monitoring, 48 V DC, 2x 10 A, 1x 20 A


 
 

Phoenix Contact 2021 © - all rights reserved


http://www.phoenixcontact.com

PHOENIX CONTACT GmbH & Co. KG


Flachsmarktstr. 8
32825 Blomberg
Germany
Tel. +49 5235 300
Fax +49 5235 3 41200
http://www.phoenixcontact.com

08/31/2021   Page 7 / 7

You might also like