X1.1 Regular periodic tests of the oven are necessary in X1.3 The values to be determined according to Test
order to ensure that the oven retains its original characteristics Methods D 5374 should include at least the following:
in service. For ovens in continuous use, these tests should be X1.3.1 The set temperature,
conducted twice a year. It is good practice to make these tests X1.3.2 The temperature variation at the set temperature, and
before beginning aging tests at a different temperature. X1.3.3 The temperature fluctuation at the center of the oven
chamber over a 24 h period.
X1.2 These tests are aimed at measuring the set tempera-
ture and temperature variations at the planned aging tempera- X1.4 The set temperature measured and reported in X1.3
ture. If possible, tests should be repeated with the oven loaded should be recorded as the aging temperature. The temperature
with specimens. variation should be within the limits given in Table 1.
X2.1 The air circulation within a forced-convection oven may be a tendency for plasticizers to be stripped more rapidly
should be considered when loading specimens into the oven from specimens in the laminar flow regions because of higher
chamber. Forced-convection ovens are designed to provide air velocity across the surface of the specimens.
uniform air temperature throughout the test chamber. This
uniformity of air temperature is achieved by using baffles, or X2.4 For maximum reproducibility of test results, speci-
different sizes of holes, or both at the air inlet and outlet to and mens should be placed in the turbulent air flow region. In an
from the chamber. empty oven chamber, the turbulent flow region occupies the
inner half of the chamber volume. This region increases
X2.2 The air flow within an oven is almost laminar at the somewhat with loading, depending upon specimen geometry
air inlet and outlet and near the walls of the test chamber. The and positioning. In any case, placement of specimens near the
air is turbulent within the center of the chamber. inlet or outlet ports should be avoided, because of the laminar
air flow.
X2.3 It has been noted that specimens positioned in the
laminar air flow regions age faster than those in the turbulent X2.5 The temperature variation in a loaded oven may differ
region. The reason for this phenomenon is not understood, but significantly from that measured in an empty oven. Therefore,
it has been observed that the leading edges of flat specimens the recommendation in X1.2 to make tests on a loaded oven,
are a degree or two hotter than the trailing edge. There also particularly with heavy loading, should be observed.
The American Society for Testing and Materials takes no position respecting the validity of any patent rights asserted in connection
with any item mentioned in this standard. Users of this standard are expressly advised that determination of the validity of any such
patent rights, and the risk of infringement of such rights, are entirely their own responsibility.
This standard is subject to revision at any time by the responsible technical committee and must be reviewed every five years and
if not revised, either reapproved or withdrawn. Your comments are invited either for revision of this standard or for additional standards
and should be addressed to ASTM Headquarters. Your comments will receive careful consideration at a meeting of the responsible
technical committee, which you may attend. If you feel that your comments have not received a fair hearing you should make your
views known to the ASTM Committee on Standards, at the address shown below.
This standard is copyrighted by ASTM, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.
Individual reprints (single or multiple copies) of this standard may be obtained by contacting ASTM at the above address or at
610-832-9585 (phone), 610-832-9555 (fax), or [email protected] (e-mail); or through the ASTM website (www.astm.org).