0% found this document useful (0 votes)
138 views2 pages

DSE892 Data Sheet (USA)

The document discusses the DSE892 SNMP Gateway which connects DSE modules to SNMP systems for monitoring and control. It can communicate with various DSE controllers to monitor instrumentation and operating state, and send SNMP traps or emails if data changes. It also has protocol conversion and supports connections via USB, RS232, RS485 and Ethernet.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
138 views2 pages

DSE892 Data Sheet (USA)

The document discusses the DSE892 SNMP Gateway which connects DSE modules to SNMP systems for monitoring and control. It can communicate with various DSE controllers to monitor instrumentation and operating state, and send SNMP traps or emails if data changes. It also has protocol conversion and supports connections via USB, RS232, RS485 and Ethernet.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

®

DSEGenset

DSE892 ENVIRONMENTAL TESTING STANDARDS

ELECTRO MAGNETIC COMPATIBILITY


SNMP GATEWAY BS EN 61000-6-2
EMC Generic Emission Standard for the
Industrial Environment
BS EN 61000-6-4
EMC Generic Emission Standard for the
DSE892 SNMP Gateway is used to Industrial Environment
COMPATIBLE DSE CONTROLLERS
connect a DSE module with an INCLUDE: ELECTRICAL SAFETY
SNMP system to give monitoring BS EN 60950
AUTO START MODULES Safety of Information Technology
and control functionality.
DSE4310 DSE7210 Equipment, including Electrical Business
DSE4410 DSE7310 Equipment
DSE892 SNMP Gateway
DSE4510 DSE7410 TEMPERATURE
communicates to the connected
DSE6010 DSE8610 BS EN 60068-2-2
controller(s), monitoring the Test Ab to +70oC 60067-2-2 Hot
DSE6110 DSE8710
instrumentation and operating state. Test Ab to -30oC 60068-2-1 Cold
DSE7110 DSE8810
If this data changes, SNMP TRAP
VIBRATION
information is generated and sent to BS EN 60068-2-6
AUTO MAINS FAILURE MODULES
the SNMP Manager. Additionally Ten sweeps in each of three major axes
DSE4320 DSE7320 5Hz to 8Hz @ +/-7.5mm, 8Hz to 500Hz @
emails can be configured to be set
DSE4420 DSE7420 2gn
to one or two email addresses.
DSE4520 DSE8620
HUMIDITY
DSE6020 DSE8660 BS 2011 part 2.1 60068-2-30
DSE892 SNMP Gateway also
DSE6120 DSE8760 Test Cb Ob Cyclic
contains a protocol conversion 93% RH @ 40oC for 48 hours
DSE7120 DSE8860
function. This cannot be utilised at
DSE7220 SHOCK
the same time as the SNMP
BS EN 60068-2-27
function. Three shocks in each of three major axes
15gn in 11mS

COMPREHENSIVE FEATURE LIST TO SUIT A


WIDE VARIETY OF APPLICATIONS
USB
RS232
SNMP MANAGER SMTP SERVER RS485
ETHERNET

ETHERNET CONNECTION TO DSE MODULE DC POWER


SUPPLY 8-35V

See above for compatible controllers

DSE892
7

OTHER

ISSUE 1
®

DSEGenset

DSE892 SPECIFICATION

DC SUPPLY
SNMP GATEWAY CONTINUOUS VOLTAGE RATING
8 V to 35 V Continuous

CRANKING DROPOUTS
Able to survive 0 V for 50 mS, providing
supply was at least 10 V before dropout
and supply recovers to 8 V. This is
achieved without the need for internal
batteries. LEDs and backlight will not be
maintained during cranking.

MAXIMUM OPERATING CURRENT


200 mA at 12 V
110 mA at 24 V

MAXIMUM STANDBY CURRENT


150 mA at 12 V
90 mA at 24 V

COMMUNICATIONS
USB (Single DSE Controller)
RS232 (Single DSE Controller)
RS485 (Multiple DSE Controllers)
Ethernet (Multiple DSE Controllers)
Ethernet SNMP & SMTP

DIMENSIONS
OVERALL
85 mm x 149 mm x 51 mm
3.3” x 5.8” x 2.0”

MOUNTING
DIN Rail
Chassis Mounting

OPERATING TEMPERATURE RANGE


-30°C to +70°C

STORAGE TEMPERATURE RANGE


-40°C to +80°C

• Supports a wide range of DSE controllers.


KEY FEATURES KEY BENEFITS

• Status LEDs for each communications port.


• Compatible with SNMP V1 specification to suit a wide

• Plug and socket connections and DIN rail mounting


range of third party SNMP management systems.

for quick and easy set up.


• A single DSE892 SNMP Gateway can be connected

• Email / SNMP TRAP messages upon controller events


to multiple controllers

and operating status change.


• Allows integration of the DSE controller into SNMP

• Fully customisable Email / SNMP TRAPs based upon


management systems. In addition to the state of the

module instrumentation values.


Generator and/or Mains Supply, this can include for

• Simple configuration via internet browser – No


example third party UPS, Fire Alarms and Security

additional PC software required.


Systems.

• Automatically generated MIB file to ease system


• Monitoring of controller state, operating mode and

integration, downloadable directly from the DSE892.


alarms.
• Connection diagnostics and basic instrumentation via
• Email by SMTP client web browser
• Configuration file upload and download for easy set
up.
• Firmware upgradeable direct via USB memory stick
or OTA (Over the Air) from DSE server.

RELATED MATERIALS
TITLE PART NO’S
DSE892 Installation Instructions 053-148
DSE892 Operations Manual 057-179

DEEP SEA ELECTRONICS PLC UK DEEP SEA ELECTRONICS INC USA


Highfield House, Hunmanby Industrial Estate, Hunmanby YO14 0PH 3230 Williams Avenue, Rockford, IL 61101-2668 USA
TELEPHONE +44 (0) 1723 890099 FACSIMILE +44 (0) 1723 893303 TELEPHONE +1 (815) 316 8706 FACSIMILE +1 (815) 316 8708
EMAIL [email protected] WEBSITE www.deepseaplc.com EMAIL [email protected] WEBSITE www.deepseausa.com

Deep Sea Electronics Plc maintains a policy of continuous development and reserves the right to change Registered in England & Wales No.01319649 055/157/02/13 (1) US
the details shown on this data sheet without prior notice. The contents are intended for guidance only. VAT No.316923457

You might also like