Installation
PoE Injector
SPIDER Giga 2TX PoE EEC
Manuals and software are protected by copyright. All rights reserved. The copying, reproduction,
translation, conversion into any electronic medium or machine scannable form is not permitted,
either in whole or in part. An exception is the preparation of a backup copy of the software for
your own use. For devices with embedded software, the end-user license agreement on the
enclosed CD/DVD applies.
The performance features described here are binding only if they have been expressly agreed
when the contract was made. This document was produced by Hirschmann Automation and
Control GmbH according to the best of the company's knowledge. Hirschmann reserves the right
to change the contents of this document without prior notice. Hirschmann can give no guarantee
in respect of the correctness or accuracy of the information in this document.
Hirschmann can accept no responsibility for damages, resulting from the use of the network
components or the associated operating software. In addition, we refer to the conditions of use
specified in the license contract.
You can get the latest version of this manual on the Internet at the Hirschmann product site
(www.hirschmann.com).
Printed in China
Hirschmann Automation and Control GmbH
Stuttgarter Str. 45-51
72654 Neckartenzlingen
Germany
Tel.: +49 1805 141538
Safety instructions 4
Legend 8
1 Description 9
1.1 General device description 9
1.2 Device view 11
1.3 Ethernet ports 11
1.3.1 10/100/1000 Mbit/s twisted pair port 11
1.3.2 10/100/1000 Mbit/s PoE port 12
1.4 Display elements 12
1.4.1 Device state 12
1.4.2 PoE status 13
2 Installation 14
2.1 Unpacking and checking the content of the package 14
2.2 Installing and grounding the device 14
2.2.1 Installing the device onto the DIN rail 14
2.2.2 Wall-Mount Plate Mounting 15
2.2.3 Grounding the device 16
2.3 Wiring the terminal block for the operating voltage 17
2.4 Operating the device 18
2.5 Connecting data cables 18
4 Disassembly 21
4.1 Removing the device from the DIN rail 21
5 Technical data 22
A Further Support 26
Certified usage
Use the device solely for the application cases described in the
Hirschmann product information, including this manual.
Operate the device solely according to the technical specifications.
See “Technical data” on page 22.
Shielding ground
The shielding ground of the connectable twisted pair lines is connected to
the ground connection as a conductor.
Beware of possible short circuits when connecting a cable section with
conductive shielding braiding.
CE marking
The labeled devices comply with the regulations contained in the following
European directive(s):
2011/65/EU (RoHS)
Directive of the European Parliament and of the Council on the restriction
of the use of certain hazardous substances in electrical and electronic
equipment.
2004/108/EC (EMC)
Directive of the European Parliament and the council for standardizing the
regulations of member states with regard to electromagnetic
compatibility.
In accordance with the above-named EU directive(s), the EU conformity
declaration will be at the disposal of the relevant authorities at the
following address:
Hirschmann Automation and Control GmbH
Stuttgarter Str. 45-51
72654 Neckartenzlingen
Germany
Tel.: +49 1805 141538
FCC note
This device complies with part 15 of the FCC rules. Operation is subject
to the following two conditions: (1) this device may not cause harmful
interference; (2) this device must accept any interference received,
including interference that may cause undesired operation.
Appropriate testing has established that this device fulfills the
requirements of a class A digital device in line with part 15 of the FCC
regulations.
These requirements are designed to provide sufficient protection against
interference when the device is being used in a business environment.
The device creates and uses high frequencies and can also radiate high
frequencies, and if it is not installed and used in accordance with this
operating manual, it can cause radio transmission interference. The use
of this device in a living area can also cause interference, and in this case
the user is obliged to cover the costs of removing the interference.
Recycling note
After usage, this device must be disposed of properly as electronic waste,
in accordance with the current disposal regulations of your county, state,
and country.
Legend
The symbols used in this manual have the following meanings:
Listing
Work step
Subheading
Power Input
Server
Power Input
Ethernet Switch
(without PoE
Power Input functionality)
PoE Injector
PoE Injector
Power Input
PoE Injector
Power Input
PoE Injector
SPIDER PD
2
1
3a 3b
1 Grounding screw
2 6-pin terminal block for the
operating voltage
3a LED display element Power Supply P1
3b LED display element Power Supply P2
4 Port 1 RJ45 socket for 10/100/1000 Mbit/s twisted-pair port
5 LED display element PoE status
6 Port 2 RJ45 socket for 10/100/1000 Mbit/s PoE port
CAUTION
TRANSIENT OR ELECTROSTATIC DISCHARGES
Note: The shielding ground of the connectable twisted pair lines is connected
to the ground connection as a conductor.
5
0.2
159,8
6.29
Note: The shielding ground of the connectable twisted pair lines is connected
to the ground connection as a conductor.
WARNING
ELECTRIC SHOCK
Never insert pointed objects (narrow screwdrivers, wires, etc.) into the
device or into the connection terminals for electric conductors. Do not touch
the connection terminals.
Operating voltage
WARNING
ELECTRIC SHOCK
Start connecting the operating voltage solely if all the above requirements
are fulfilled.
See “Operating voltage” on page 5.
CAUTION
ELECTRIC SHOCK
Connect solely an operating voltage that corresponds to the type plate of
your device.
Failure to follow these instructions can result in injury or equipment
damage.
Figure 1: The PoE Injector device loops-through 1:1 the data paths connected to
the pins.
1: Data
2: Data + PoE
Note: You will find information about the complaints and returns procedures
in the Internet under
http://www.beldensolutions.com/en/Service/Repairs/index.phtml .
mm
inch
0.35
9
1.77
45
47,05
5.51
1.85
140
30 95
1.18 3.74
104
4.09
EMC interference
emission
Radiated emission
FCC 47 CFR Part 15 Class A
EN 61000-6-4 Fulfilled
Conducted emission
FCC 47 CFR Part 15 Class A
EN 61000-6-4 Fulfilled
EMC interference
immunity
Electrostatic discharge
EN 61000-4-2 Contact discharge ± 4 kV
IEEE C37.90.3
EN 61000-4-2 Air discharge ± 8 kV
IEEE C37.90.3
Electromagnetic field
EN 61000-4-3 80 MHz ... 1000 MHz 10 V/m
EN 61000-4-3 1.4 GHz ... 2 GHz 3 V/m
EN 61000-4-3 2 GHz ... 2.7 GHz 1 V/m
Fast transients (burst)
EN 61000-4-4 DC supply connection ± 2 kV
IEEE C37.90.1
EN 61000-4-4 Data line ± 1 kV
IEEE C37.90.1
Voltage surges - DC supply connection
EN 61000-4-5 line/ground ± 0.5 kV
EN 61000-4-5 line/line ± 0.5 kV
Conducted disturbances
EN 61000-4-6 150 kHz ... 80 MHz 10 V
Stability
IEC 60068-2-6, test Fc Vibration 3 Hz ... 9 Hz with 0.14 in.
(3.5 mm) amplitude
9 Hz ... 150 Hz with
0.04 oz (1 g)
IEC 60068-2-27, Test Ea Shock 0.53 oz (15 g) at 11 ms
Network range
The total length permitted for the twisted-pair cables connected to port 1
and port 2 is a maximum of 109 yards (100 m).
Number Article
1× Device
1× 6 pin, pluggable terminal block for redundant power supply
1× Wall mounting set
1× Installation user manual
Order number
Device Order number
SPIDER Giga 2TX PoE EEC 942 059-001
Accessories
Other accessories Order number
Rail Power Supply RPS60/48V EEC 943 952-001
Rail Power Supply RPS 80 EEC 943 662-080
The device generally fulfills the norms and standards named in their
current versions.
The device has a certification based on a specific standard or de facto
standard solely if the certification indicator appears on the housing.