Focus on Therapy,
Applicable to Various Settings
Ultra compact ---- Lightweight and portable, taking up the least space.
Large screen ---- 4.3-inch color touch screen, easy to observe and operate.
Ultra quiet ---- Fanless design, noise free, ensuring a quiet and comfort environment.
Trolley design ---- Convenient to move, seamless integration of different settings,
including radiant warmer and baby cradle bed.
Quick-release structure ---- The main unit can be quickly separated from the trolley
and placed directly on the incubator hood.
Flexible adjustment ---- Easy adjustment of height and angle.
BL70
Infant Phototherapy
Shenzhen Comen Medical Instruments Co., Ltd. P/N:EN-BL70-4P-20200718-V1.0
Add: No.2 of FIYTA Timepiece Building, Nanhuan Avenue, Matian Sub-district, Guangming District, Shenzhen, 518106, Guangdong, China.
Tel:+86-755-2640 8879 400-700-9488 Fax:+86-755-2643 1232 Website: en.comen.com E-mail: [email protected]
High-intensity Phototherapy
Efficient Jaundice Treatment High-intensity irradiance Longer service life
According to statistics, clinically 80% of pre-term and 60% of full-term infants are at risk of
Equipped with high-intensity LED cold light source, with The service life is up to 50,000 hours, ensuring
hyperbilirubinemia.
less heat production, BL70 supports long-time treatment. clinical usage and minimizing the cost for the end
BL70 Infant Phototherapy helps cure jaundice safely and efficiently with superior technology and
With the maximal irradiance level of 63μW/cm²/nm, users.
high-performance phototherapy.
BL70 enhances the bilirubin breakdown ability and
shortens the treatment time.
With five levels irradiance adjustment, BL70 allows
treatment tailored to each patient’s needs.
Optimal wavelength Uniform irradiance distribution
The peak wavelength of the spectrum is 449 - 461 nm Our innovative optical design ensures uniform
and has been shown by the American Academy of irradiance distribution, minimizes spill light and
Pediatrics (AAP) to be the most effective in reducing exposure, with LED light evenly covering the total
unconjugated bilirubin; it also does not contain near-UV body surface of the neonates to ensure the effect
wavelengths that are harmful to the skin. These made it of phototherapy.
very suitable for the treatment of neonatal jaundice.
Bilirubin breakdown rate (%)
Effective bilirubin
irradiance distribution
(μW/cm2/nm)
Spectral irradiance distribution graph
Wavelengths (nm)
Precise Treatment for
Irradiance probe
Neonatal Jaundice
After clarification using irradiance probe, Ward round assistance
Equipped with an irradiance probe to
phototherapy irradiance value of 5 levels
accurately measure the irradiance value and
can be displayed on the screen. When doctors round the wards, there is
ensures that the baby receives enough
no need to open the cover, the condition
irradiance, achieving precise treatment.
of neonates can be checked through the
Precise positioning screen in real time, reducing undesired
blue light exposure.
Using unique red light precise positioning,
BL70 ensures correct position of the baby.