Contactor Catalogue: According To CE, IEC 947, EN 60947

The document provides information on mini-contactors, mini-relays, contactors and accessories such as: - Mini-contactors are available from 4.5kW to 5.5kW with AC or DC coil voltages and optional auxiliary contacts. - Mini-relays are 10A thermal rated, have screw terminals and optional auxiliary contact blocks. - Contactors are available from 10A to 22A with AC coil voltages and optional auxiliary contacts. They have ratings for AC3 up to 315A and AC1 up to 500A.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
508 views20 pages

Contactor Catalogue: According To CE, IEC 947, EN 60947

The document provides information on mini-contactors, mini-relays, contactors and accessories such as: - Mini-contactors are available from 4.5kW to 5.5kW with AC or DC coil voltages and optional auxiliary contacts. - Mini-relays are 10A thermal rated, have screw terminals and optional auxiliary contact blocks. - Contactors are available from 10A to 22A with AC coil voltages and optional auxiliary contacts. They have ratings for AC3 up to 315A and AC1 up to 500A.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 20

According to CE,

IEC 947, EN 60947

Contactor Catalogue

3 Pole & 4 Pole Contactors 4kW - 160kW Thermal Overload

Mini-Contactors 4kW - 5.5kW DC Contactors

Mini-Relays 10A Motor Starter DOL, Star-Delta

Capacitor Switching Modular Contactors (for Distribution Board DB)


Mini-Contactors
• Compact frame size up to AC3 5.5kW
• Screw connection terminals
• DIN-Rail or Screw Base Mount

AC3 AC1 Auxiliary Contact


380-415V Rated Current Type
NO NC
KW A
3P - AC Operated *230Vac coil voltage AC Coil Voltage Coding
4.5 20 1 - 9B K1-09D 10 A230 Code Volts 50Hz Volts 60 Hz
4.5 20 - 1 9B K1-09D 01 A230 A024 22-24V 22-27V
A042 42-47V 47-52V

5.5 20 1 - 9B K1-12D 10 A230 A110 100-110V 110-122V

5.5 20 - 1 9B K1-12D 01 A230 A127 122-135V 135-150V


A230 220-240V 230-264V

4P - AC Operated 230Vac coil voltage A400 380-415V 400-460V

4.5 20 - - 9B K1-09D 0040 A230


4.5 20 1 1 9B K1-09D 0040 A230 SIS0011

3P - DC Operated *24Vdc coil voltage DC Coil Voltage Coding


4.5 20 1 - 9B K1-09D 10 D024 Code Volts
4.5 20 - 1 9B K1-09D 01 D024 D024 24Vdc
D048 48Vdc

5.5 20 1 - 9B K1-12D 10 D024 D110 110Vdc

5.5 20 - 1 9B K1-12D 01 D024 D220 220Vdc

4P - DC Operated 24Vdc coil voltage *Other coil voltages, Please consult us.
4.5 20 - - 9B K1-09D 0040 D024
4.5 20 1 1 9B K1-09D 0040 D024 SIS0011

Accessories

Type Voltage Range


Coil RC Supressor Unit for K1 Relay & Mini-
9B RC-K124 12-48V ac/dc 1600nF/22 ohm
contactor to protect contactor coil against
voltage peaks and harmonic waves. 9B RC-K1110 48-127V ac/dc 680nF/270 ohm
To snap on to contactor 9B RC-K1230 110-250V ac/dc 220nF/2200 ohm

2
Mini-Relays
• 10A thermal Ith rating
• Suitable for electronic circuit
• DIN-rail or Screw Base Mounting
• Screw terminals
• Add Aux Contact Block - up to 8 contacts available

AC15 Ith Contact


230V Thermal Type
NO NC
Current
A A
Mini Relay AC *230Vac coil voltage AC Coil Voltage Coding
Operated Code Volts 50Hz Volts 60 Hz
3 10 4 - 9B K1-07D 40 A230 A024 22-24V 22-27V

3 10 3 1 9B K1-07D 31 A230 A042 42-47V 47-52V

3 10 2 2 9B K1-07D 22 A230 A110 100-110V 110-122V


A127 122-135V 135-150V
A230 220-240V 230-264V
A400 380-415V 400-460V

Mini Relay DC 24Vdc coil voltage DC Coil Voltage Coding


Operated Code Volts
3 10 4 - 9B K1-07D 40 D024 D024 24Vdc

3 10 3 1 9B K1-07D 31 D024 D048 48Vdc

3 10 2 2 9B K1-07D 22 D024 D110 110Vdc


D220 220Vdc

*Other coil voltages Please consult us.

Auxillary Add on Contact Block for Mini Contactors and Mini-Relays


AC15 Ith
230V Thermal NO NC Type
Current
A A
3 10 1 1 9B HK11
3 10 - 2 9B HK02
3 10 2 - 9B HK20
3 10 4 - 9B HK40
3 10 2 2 9B HK22
3 10 - 4 9B HK04

Ordering Example : Required 4 NO + 4 NC relay contacts (coil AC230) :-

Order 1pcs 9B K1 07D 40 A230 (4 NO) + 1pc 9B HK04 (4 NC)

3
Contactors 3-pole
• Up to 315A AC3
• Up to 500A AC1
• DIN-rail mounting up to AC3 115A
• International Approvals
• Data according to IEC 947 / EN 60947

Ratings
AC3 400V Motor 10A 14A 18A 22A

400-415V 4kW 5.5kW 7.5kW 11kW


660-690V 5.5kW 7.5kW 10kW 10kW
AC1 690V at 40°C 25A 25A 32A 32A
Auxiliary contacts Type AC Coil Voltage Coding
*230AC Coil Code Volts Volts
NO NC 50Hz 60Hz
1 0 9B K3-10ND 10 A230 9B K3-14ND 10 A230 9B K3-18ND 10 A230 9B K3-22ND 10 A230 A024 22-24V 22-27V

0 1 9B K3-10ND 01 A230 9B K3-14ND 01 A230 9B K3-18ND 01 A230 9B K3-22ND 01 A230 A042 42-47V 47-52V

1 1 - - - - A110 100-110V 110-122V

0 0 - - - - A127 122-135V 135-150V

Cable cross-section A230 220-240V 230-264V

Solid mm2 0.75 - 6 A400 380-415V 400-460V

Flexible mm 2
1-4
Cables per clamp 2

Auxiliary contact
Ith 40°C A 16
AC15 230V A 12
400V A 4

Power consumption DC Coil Voltage Coding


of coils
Inrush VA 33 - 45 Code Volts
hold VA 7 - 10 D024 24Vdc

Operation range of coils 0.85 - 1.1 D048 48Vdc

D110 110Vdc

Mounting 35mm DIN-rail or base D220 220Vdc

Additional aux.

*Other coil voltages, Please
Contact Rating 10A

contact blocks 9B 9B consult us.
Maximun 4HN
Front mounting Type HN10
1NO
HN01
1NC
• Suitable for low Voltage (17V, 5mA)
contacts
Additional aux.
contact blocks
- - - -
Side mounting Type
contacts
Thermal Overload
TOR For K3-10 to K3-22
Relay
Setting Range Type
*3 elements type thermal 0.12 - 0.18A 9B U12/16E 0.18 K3
relay
0.18 - 0.27A 9B U12/16E 0.27 K3

*Automatic Temperature 0.27 - 0.4A 9B U12/16E 0.4 K3


compensation for 0.4 - 0.6A 9B U12/16E 0.6 K3
ambient Temperature
0.6 - 0.9A 9B U12/16E 0.9 K3
-25 to +60 Deg C
0.8 - 1.2A 9B U12/16E 1.2 K3
*Trip Class 10A to IEC 1.2 - 1.8A 9B U12/16E 1.8 K3
947 - 4 - 1 1.8 - 2.7A 9B U12/16E 2.7 K3
2.7 - 4.0A 9B U12/16E 4 K3
*Protect against:-
4.0 - 6.0A 9B U12/16E 6 K3
- Overload Current
6.0 - 9.0A 9B U12/16E 9 K3
- Phase Unbalance
- Single Phase Failure 8.0 - 11.0A 9B U12/16E 11 K3
10.0 - 14.0A 9B U12/16E 14 K3
13.0 - 18.0A 9B U12/16E 18 K3
17.0 - 23.0A 9B U12/16E 23 K3
22.0 - 30.0A 9B U12/16E 30 K3

4
Contactors 3-pole
• Climate resistant, suitable for extreme humidity application
• Ambient temperature -40 Deg C .. 90Deg C
• Large cable cross sections termination area
• HN ..auxiliary contact suitable for electronics circuit (17V, 5mA)
• Minimum size and Maximun performance

Ratings
AC3 400V Motor 24A 32A 40A

400-415V 11kW 15kW 18.5kW


660-690V 15kW 18.5kW 18.5kW
AC1 690V at 40°C 50A 65A 80A
Auxiliary contacts Type AC Coil Voltage Coding
*230AC Coil Code Volts Volts
NO NC 50Hz 60Hz
1 0 9B K3-24A 00 A230 SIS 0010 9B K3-32A 00 A230 SIS 0010 9B K3-40A 00 A230 SIS 0010 A024 22-24V 22-27V

0 1 - - - A042 42-47V 47-52V

1 1 - - - A110 100-110V 110-122V

0 0 9B K3-24A 00 A230 9B K3-32A 00 A230 9B K3-40A 00 A230 A127 122-135V 135-150V

Cable cross-section A230 220-240V 230-264V

Solid mm2 1.5 - 25 A400 380-415V 400-460V

Flexible mm 2
2.5 - 16
Cables per clamp 1+1

Auxiliary contact
Ith 40°C A -
AC15 230V A -
400V A -

Power consumption DC Coil Voltage Coding


of coils
Inrush VA 90 - 115 Code Volts
hold VA 9 - 13 D024 24Vdc

Operation range of coils 0.85 - 1.1 D048 48Vdc

D110 110Vdc

Mounting 35mm DIN-rail or base D220 220Vdc

Additional aux.
• Contact Rating 10A
contact blocks 9B HN10 9B HN01
• Maximun 4HN
Front mounting Type 1NO 1NC
• Suitable for low Voltage (17V, 5mA) *Other coil voltages, Please
consult us.
contacts
Additional aux.
• Contact Rating 10A
contact blocks 9B HB11 9B HB02
• Maximun 2HB
Side mounting Type 1NO+1NC 2NC
• Suitable for low Voltage (17V, 5mA)
contacts
Thermal Overload
Relay
TOR FOR K3-24 TO K3-40
*3 elements type thermal Setting Ranges Type
relay 10 - 14A 9B U3/4214
14 - 20A 9B U3/4220
*Automatic Temperature
compensation for
20 - 28A 9B U3/4228
ambient Temperature 28 - 42A 9B U3/4242
-25 to +60 Deg C

*Trip Class 10A to IEC


947 - 4 - 1

*Protect against:-
- Overload Current
- Phase Unbalance
- Single Phase Failure

5
Contactors 3-pole
• Up to 315A AC3
• Up to 500A AC1
• DIN-rail mounting up to AC3 115A
• International Approvals
• Data according to IEC 947 / EN 60947

Ratings
AC3 400V Motor 50A 62A 74A

400-415V 22kW 30kW 37kW


660-690V 30kW 37kW 45kW
AC1 690V at 40°C 110A 120A 130A
Auxiliary contacts Type AC Coil Voltage Coding
*230AC Coil Code Volts Volts
NO NC 50Hz 60Hz
1 0 9B K3-50A 00 A230 SIS 0010 9B K3-62A 00 A230 SIS 0010 9B K3-74A 00A 230 SIS 0010 A024 22-24V 22-27V

0 1 - - - A042 42-47V 47-52V

1 1 - - - A110 100-110V 110-122V

0 0 9B K3-50A 00 A230 9B K3-62A 00 A230 9B K3-74A 00 A230 A127 122-135V 135-150V

Cable cross-section A230 220-240V 230-264V

Solid mm2 4 - 50 A400 380-415V 400-460V

Flexible mm 2
10 - 35
Cables per clamp 1+1

Auxiliary contact
Ith 40°C A -
AC15 230V A -
400V A -

Power consumption DC Coil Voltage Coding


of coils
Inrush VA 140 - 165 Code Volts
hold VA 13 - 18 D024 24Vdc

Operation range of coils 0.85 - 1.1 D048 48Vdc

D110 110Vdc

Mounting 35mm DIN-rail or base D220 220Vdc

Additional aux.
• Contact Rating 10A
contact blocks 9B HN10 9B HN01
• Maximun 4HN
Front mounting Type 1NO 1NC
• Suitable for low Voltage (17V, 5mA) *Other coil voltages, Please
consult us.
contacts
Additional aux.
• Contact Rating 10A
contact blocks 9B HB11 9B HB02
• Maximun 2HB
Side mounting Type 1NO+1NC 2NC
• Suitable for low Voltage (17V, 5mA)
contacts
Thermal Overload
Relay
TOR FOR K3-50 TO K3-74
*3 elements type thermal Setting Ranges Type
relay 20 - 28A 9B U3/7428
28 - 42A 9B U3/7442
*Automatic Temperature
40 - 52A 9B U3/7452
compensation for
ambient Temperature 52 - 65A 9B U3/7465
-25 to +60 Deg C 60 - 74A 9B U3/7474

*Trip Class 10A to IEC


947 - 4 - 1

*Protect against:-
- Overload Current
- Phase Unbalance
- Single Phase Failure

6
Contactors 3-pole
• Climate resistant, suitable for extreme humidity application
• Ambient temperature -40 Deg C .. 90Deg C
• Large cable cross sections termination area
• HN ..auxiliary contact suitable for electronics circuit (17V, 5mA)
• Minimum size and Maximun performance

Ratings
AC3 400V Motor 90A 115A

400-415V 45kW 55kW


660-690V 55kW 55kW
AC1 690V at 40°C 160A 200A
Auxiliary contacts Type AC Coil Voltage Coding
*230AC Coil Code Volts Volts
NO NC 50Hz 60Hz
1 0 9B K3-90A 00 A230 SIS 0010 9B K3-115A 00 A230 SIS 0010 A024 22-24V 22-27V

0 1 - - A042 42-47V 47-52V

1 1 - - A110 100-110V 110-122V

0 0 9B K3-90A 00 A230 9B K3-115A 00 A230 A127 122-135V 135-150V

Cable cross-section A230 220-240V 230-264V

Solid mm2 120 + 95 A400 380-415V 400-460V

Flexible mm 2
95 + 70
Cables per clamp 1+1

Auxiliary contact
Ith 40°C A -
AC15 230V A -
400V A -

Power consumption DC Coil Voltage Coding


of coils
Inrush VA 280 Code Volts
hold VA 5 D024 24Vdc

Operation range of coils 0.85 - 1.1 D048 48Vdc

D110 110Vdc

Mounting 35mm DIN-rail or base D220 220Vdc

Additional aux.
• Contact Rating 10A
contact blocks 9B HN10 9B HN01
• Maximun 7HN
Front mounting Type 1NO 1NC
• Suitable for low Voltage (17V, 5mA) *Other coil voltages, Please
consult us.
contacts
Additional aux.
• Contact Rating 10A
contact blocks 9B HB11 9B HB02
• Maximun 2HB
Side mounting Type 1NO+1NC 2NC
• Suitable for low Voltage (17V, 5mA)
contacts
Thermal Overload
Relay TOR FOR K3-90 TO K3-115
Setting Ranges Type
*3 elements type thermal
relay 60 - 90A 9B U8590
80 - 120A 9B U85120
*Automatic Temperature
compensation for
ambient Temperature
-25 to +60 Deg C

*Trip Class 10A to IEC


947 - 4 - 1

*Protect against:-
- Overload Current
- Phase Unbalance
- Single Phase Failure

7
Contactors 3-pole
• Up to 315A AC3
• Up to 500A AC1
• DIN-rail mounting up to AC3 115A
• International Approvals
• Data according to IEC 947 / EN 60947

Ratings
AC3 400V Motor 150A 175A

400-415V 75kW 90kW


660-690V 90kW 110kW
AC1 690V at 40°C 230A 250A
Auxiliary contacts Type AC Coil Voltage Coding
*230AC Coil Code Volts Volts
NO NC 50Hz 60Hz
1 0 - - A024 22-24V 22-27V

0 1 - - A042 42-47V 47-52V

1 1 9B K3-151A 00 A230 SIS 0011 9B K3-176A 00 A230 SIS 0011 A110 100-110V 110-122V

0 0 9B K3-151A 00 A230 9B K3-176A 00 A230 A127 122-135V 135-150V

Cable cross-section A230 220-240V 230-264V

Solid mm2 2 x 16 - 120 A400 380-415V 400-460V

Flexible mm 2
2 x 16 - 120
Cables per clamp 1+1

Auxiliary contact
Ith 40°C A -
AC15 230V A -
400V A -

Power consumption DC Coil Voltage Coding


of coils
Inrush VA 350 Code Volts
hold VA 5 D024 24Vdc

Operation range of coils 0.85 - 1.1 D048 48Vdc

D110 110Vdc

Mounting Base D220 220Vdc

Additional aux.
9B HKT11 9B HKT22 • Contact Rating 10A
contact blocks
1NO + 1NC 2NO + 2NC • Maximun 1 HKT
Front mounting Type *Other coil voltages, Please
contacts consult us.
Additional aux.
contact blocks • Contact Rating 10A

9B HKA11
1NO + 1NC Maximun 1 HKA
Side mounting Type
contacts
Thermal Overload
Relay TOR FOR K3-151 TO K3-176
Setting Ranges Type
*3 elements type thermal 120 -180A 9B U180180
relay Links for independent 9B SU180/176
mounting
*Automatic Temperature (Basbar set)
compensation for
ambient Temperature
-25 to +60 Deg C
Or alternatively used with C.T. ( Not supplied)
*Trip Class 10A to IEC Current Range TOR Type Current Transformer
947 - 4 - 1 (C.T)
120 - 180A 9B U12/16E1.8 500 : 5
*Protect against:- (1.2 - 1.8A)
- Overload Current
+
- Phase Unbalance
- Single Phase Failure 9B U12SM
(Din-Rail
Mounting Unit)

8
Contactors 3-pole
• Climate resistant, suitable for extreme humidity application
• Ambient temperature -40°C .. 70°C
• Large cable cross sections termination area
• HN ..auxiliary contact suitable for electronics circuit (17V, 5mA)
• Minimum size and Maximun performance

Ratings
AC3 400V Motor 210A 260A 315A

400-415V 110kW 132kW 160kW


660-690V 160kW 210kW 250kW
AC1 690V at 40°C 350A 450A 500A
Auxiliary contacts Type AC Coil Voltage Coding
*230AC Coil Code Volts Volts
NO NC 50Hz 60Hz
1 0 - - - A024 22-24V 22-27V

0 1 - - - A042 42-47V 47-52V

1 1 9B K3-210A 00 A230 SIS 0011 9B K3-260A 00 A230 SIS 0011 9B K3-316A 00 A230 SIS 0011 A110 100-110V 110-122V

0 0 9B K3-210A 00 A230 9B K3-260A 00 A230 9B K3-316A 00 A230 A127 122-135V 135-150V

Cable cross-section A230 220-240V 230-264V

Solid mm2 busbar A400 380-415V 400-460V

Flexible mm 2
30 x 6
Cables per clamp

Auxiliary contact
Ith 40°C A -
AC15 230V A -
400V A -

Power consumption DC Coil Voltage Coding


of coils
Inrush VA 360 Code Volts
hold VA 5 D024 24Vdc

Operation range of coils 0.85 - 1.1 D048 48Vdc

D110 110Vdc

Mounting Base D220 220Vdc

Additional aux.
9B HKT11 9B HKT22 • Contact Rating 10A
contact blocks
1NO + 1NC 2NO + 2NC • Maximun 1 HKT
Front mounting Type *Other coil voltages, Please
contacts consult us.
Additional aux.
contact blocks • Contact Rating 10A

9B HKA11
1NO + 1NC Maximun 1 HKA
Side mounting Type
contacts
Thermal Overload
Relay TOR FOR K3-210 TO K3-316
Setting Ranges Type
*3 elements type thermal 144 - 320A 9B U320320
relay

*Automatic Temperature
compensation for Or alternatively used with C.T. ( Not supplied)
ambient Temperature Current Range TOR Type Current Tranformer
-25 to +60 Deg C (C.T)
180 - 270A 9B U12/16E27 500:5
*Trip Class 10A to IEC (1.8 - 2.7A)
947 - 4 - 1 +
9B U12SM
(Din-Rail
*Protect against:- Mounting Unit)
- Overload Current
- Phase Unbalance 270 - 400A 9B U12/16E27 500:5
(2.7 - 4A)
- Single Phase Failure +
9B U12SM
(Din-Rail
Mounting Unit)

9
4 Poles Contactor
• AC1 rated 25A to 500A
• AC3 rated 4KW to 160KW
• Compact and space saving design
• Suitable for applications such as switching heating circuits, as
generator, as bypass or changeover contactor.
K3-10A K2-45A K3-151A

AC3 AC1
AC1 690V Auxiliary Contact
(Motor) (Resistive)
380-415V 400V Rated Current Type
kW kW A NO NC
4 17.5 25 1 - 9B K3-10NA 0040 A230 SIS0010 AC Coil Voltage Coding
Code Volts Volts
17.5 22 32 1 - 9B K3-18NA 0040 A230 SIS0010 50Hz 60Hz
A024 22-24V 22-27V

11 31 45 1 - 9B K2-23A 0040 A230 SIS0010 A042 42-47V 47-52V

A110 100-110V 110-122V

15 34.5 50 1 - 9B K2-30A 0040 A230 SIS0010 A127 122-135V 135-150V

A230 220-240V 230-264V

22 55 80 1 - 9B K2-45A 0040 A230 SIS0010 A400 380-415V 400-460V

30 69 100 1 - 9B K2-60A 0040 A230 SIS0010


DC Coil Voltage Coding
55 139 200 1 1 9B K3-116A 0040 A230 SIS0011 Code Volts
D024 24Vdc

75 159 230 1 1 9B K3-151A 0040 A230 SIS0011 D048 48Vdc

D110 110Vdc

90 173 250 1 1 9B K3-176A 0040 A230 SIS0011 D220 220Vdc

110 242 350 1 1 9B K3-210A 0040 A230 SIS0011 *Other coil voltages, Please
consult us.

132 310 450 1 1 9B K3-260A 0040 A230 SIS0011

160 346 500 1 1 9B K3-316A 0040 A230 SIS0011

Contactor 4-pole, AC operated


K3-10NA 00-40 K2-23A 00-40 K2-45A 00-40
K3-14NA 00-40 K2-30A 00-40 K2-60A 00-40
K3-18NA 00-40 K2-37A 00-40
K3-22NA 00-40

K3-116A 00-40 K3-210A 00-40


K3-151A 00-40 K3-260A 00-40
K3-176A 00-40 K3-316A 00-40

10
4 Poles Change-Over Contactor
• AC1 rated 25A to 450A
• AC3 rated 4KW to 132KW
• Compact and space saving design
• Consists of 2 contactors fitted with mechanical interlock
• Suitable for Mains disconnection and Mains changeover,
Switching of heating system and 4-pole load switching

AC3 AC1
AC1 690V Auxiliary Contact
(Motor) (Resistive)
Rated
380-415V 400V Type
Current
KW KW A NO NC
* 230Vac coil voltage
(220V - 240ac)
4 17.5 25 2 2 9B K3-WU10-40 A230 SIS0001 AC Coil Voltage Coding
Code Volts Volts
7.5 22 32 2 2 9B K3-WU18-40 A230 SIS0001 50Hz 60Hz
A024 22-24V 22-27V

11 31 45 2 2 9B K3-WU23-40 A230 SIS0001 A042 42-47V 47-52V

A110 100-110V 110-122V

15 34.5 50 2 2 9B K3-WU30-40 A230 SIS0001 A127 122-135V 135-150V

A230 220-240V 230-264V

22 55 80 2 2 9B K3-WU45-40 A230 SIS0001 A400 380-415V 400-460V

30 69 100 2 2 9B K3-WU60-40 A230 SIS0001 DC Coil Voltage Coding


Code Volts
55 139 200 2 2 9B K3-WU116-40 A230 SIS0001 D024 24Vdc

D048 48Vdc

75 159 230 2 2 9B K3-WU151-40 A230 SIS0001 D110 110Vdc

D220 220Vdc

90 173 250 2 2 9B K3-WU176-40 A230 SIS0001

110 242 350 2 2 9B K3-WU210-40 A230 SIS0001

132 310 450 2 2 9B K3-WU260-40 A230 SIS0001 *Other coil voltages, Please
consult us.

Dimensions

Interlock
Type
Contactor 1 Contactor 1 A1 A2 A3 B1 B2 C1 C2 C3 D1 D2

9B LG10889 K3-10 to K3-40 K3-10 to K3-40 45 7 45 50 50 35 17 35 4.5 4.5


9B LG10889 K2-23 to K2-37 K2-23 to K2-37 58 7 58 65 65 45 20 45 4.5 4.5

9B LG10890 K3-50 to K3-74 K3-24 to K3-40 60 12 55 100 65 50 22 45 5.5 5.5


9B LG10890 K3-50 to K3-74 K3-50 to K3-74 60 12 60 100 100 50 22 50 5.5 5.5
9B LG10890 K3-90 to K3-115 K3-90 to K3-115 90 12 90 100 100 75 27 75 5.5 5.5
9B LG10890 K2-45 to K2-60 K2-45 to K2-60 79 12 79 100 100 69 22 69 5.5 5.5

9B LG11223H K3-115, -176 K3-115, -176 110 30 110 130 130 100 40 100 6 6 3-pole Contactor
9B LG11223H K3-116, -151, -176 K3-116, -151, -176 147 30 147 130 130 135 42 135 6 6 4-pole Contactor
9B LG11223H K3-210, -260, -316 K3-210, -260, -316 145 30 145 160 160 120 55 120 6 6 3-pole Contactor
9B LG11223H K3-210, -260, -316 K3-210, -260, -316 193 30 193 160 160 170 55 170 6 6 4-pole Contactor

11
Contactors 3-pole DC Coil Control
• AC1 rated 25A to 500A
• AC3 rated 4KW to 160KW
• Use in DC Applications with lead - acid batteries, rectified power, battery charger & UPS etc..
• For application when Main Supply is AC and Contactor coil voltage is DC

K3-14A K3-50A

AC3 (Motor) AC1 (Resistive) AC1 690V Auxiliary Contact DC Coil Voltage Coding
380-415V 400V Rated Current Type Code Volts
kW kW A NO NC D024 24Vdc

*Coil Voltage 24Vdc D048 48Vdc

4 17.5 25 1 - 9B K3-10ND 10 D024 D110 110Vdc

4 17.5 25 - 1 9B K3-10ND 01 D024 D220 220Vdc

5.5 17.5 25 1 - 9B K3-14ND 10 D024


5.5 17.5 25 - 1 9B K3-14ND 01 D024
7.5 22 32 1 - 9B K3-18ND 10 D024
7.5 22 32 - 1 9B K3-18ND 01 D024
11 22 32 1 - 9B K3-22ND 10 D024
11 22 32 - 1 9B K3-22ND 01 D024
DC operated with double coil
11 34.6 50 - - 9B K3-24A 00 D024
winding for K3-10A to K3-74A
15 45 65 - - 9B K3-32A 00 D024 contactor
18.5 55 80 - - 9B K3-40A 00 D024
22 76 110 - - 9B K3-50A 00 D024
30 83 120 - - 9B K3-62A 00 D024
37 90 130 - - 9B K3-74A 00 D024
45 110 160 - - 9B K3-90A 00 A024
55 139 200 - - 9B K3-115A 00 A024
75 159 230 - - 9B K3-151A 00 A024 DC operated with double coil
90 173 250 - - 9B K3-176A 00 A024 winding for K3-90A, K3-115A,
K3-151A, K3-176A, K3-210A,
110 242 350 - - 9B K3-210A 00 A024 K3-260A.
132 310 450 - - 9B K3-260A 00 A024 K3-316A contactor

160 346 500 - - 9B K3-316A 00 A024

Add On Auxiliary Contact block (AC1 10A rating) TYPE


K3 10ND to K3 74A - Maximum 3 HN.. 1 NO 9B HN10
K3 90A to K3 115A - Maximum 7 HN.. 1NC 9B HN01

For K3 151A to K3 316A contactors 1NO + 1NC 9B HKT11


Maximum 1 HKT 2NO + 2NC 9B HKT22 HN HKT
Accessories

Interface for contactors K3-10ND to K3-74A Type


Input Voltage 24V dc, Amplifier element for
9B K2 IM
contactor control by PLC programmable
controller.

Coil RC Suppressor Unit for Contactors Type Voltage Range


K3-10ND to K3-74A 9B RC-K3N24 12-48V ac/dc 1600nF/22 ohm
To protect contactor coil against voltage 9B RC-K3N110 48-172V ac/dc 680nF/270 ohm
peaks and harmonic wave. 9B RC-K3N230 110-250V ac/dc 220nF/2200 ohm
To snap on to contactor 9B RC-K3N400 230-415V ac/dc 120nF/620 ohm

12
Contactors 3-pole Main Contacts DC Load supply - Ampere Rating
Utilization Category DC1 Type 9B K1-09D 9B K1-12D 9B K3 10ND 9B K3 14ND 9B K3 18ND 9B K3 22ND 9B K3 24A 9B K3 32A 9B K3 40A 9B K3 50A
Switching of Resitive load Time
Contstant L/R ,1ms
Rated operation current le DC
24V 20A 20A 20A 25A 32A 32A 50A 65A 80A 110A
60V 20A 20A 20A 25A 32A 32A 50A 65A 80A 110A
110V 5A 5A 6A 6A 6A 6A 10A 10A 10A 12A
1 pole
220V 0.6A 0.6A 0.8A 0.8A 0.8A 0.8A 1.4A 1.4A 1.4A 1.4A

Utilization Category DC1 Type 9B K3-62A 9B K3-74A 9B K3-90A 9B K3-115A


Switching of Resitive load Time
Contstant L/R ,1ms
Rated operation current le DC
24V 120A 130A 160A 200A
60V 120A 130A 160A 200A
110V 12A 20A 20A 25A
1 pole
220V 1.4A 1.4A 2A 2.5A

Utilization Category DC1 Type 9B K1-09D 9B K1-12D 9B K3 10ND 9B K3 14ND 9B K3 18ND 9B K3 22ND 9B K3 24A 9B K3 32A 9B K3 40A 9B K3 50A
Switching of Resitive load Time
Contstant L/R ,1ms
Rated operation current le DC
24V 20A 20A 20A 25A 32A 32A 50A 65A 80A 110A
60V 20A 20A 20A 25A 32A 32A 50A 65A 80A 110A
110V 20A 20A 20A 25A 32A 32A 50A 65A 80A 110A
3 poles In Series
220V 16A 16A 16A 20A 20A 20A 30A 35A 35A 63A

Utilization Category DC1 Type 9B K3 62A 9B K3 74A 9B K3 90A 9B K3 115A 9B K3 151A 9B K3 176A 9B K3 210A 9B K3 260A 9B K3 316A
Switching of Resitive load Time
Contstant L/R ,1ms
Rated operation current le DC
24V 120A 130A 160A 200A 200A 250A 350A 400A 450A
60V 120A 130A 160A 200A 200A 250A 350A 400A 450A
110V 120A 130A 160A 200A 150A 170A 250A 280A 315A
3 poles In Series
220V 80A 80A 100A 160A 80A 100A 150A 180A 200A

Utilization Category DC3 & DC5 Type 9B K1-09D 9B K1-12D 9B K3 10ND 9B K3 14ND 9B K3 18ND 9B K3 22ND 9B K3 24A 9B K3 32A 9B K3 40A 9B K3 50A
Switching of Inductive load
Time Contstant L/R < 15ms
Rated operation current le DC
24V 20A 20A 20A 25A 32A 32A 50A 65A 80A 110A
60V 5A 5A 6A 6A 6A 6A 30A 30A 30A 60A
110V 1A 1A 1.2A 1.2A 1.2A 12.2A 1.8A 1.8A 1.8A 1.8A
1 pole
220V 0.15A 0.15A 0.2A 0.2A 0.2A 0.2A 0.2A 0.2A 0.2A 0.25A

Utilization Category DC3 & DC5 Type 9B K3 62A 9B K3 74A 9B K3 90A 9B K3 115A
Switching of Inductive load
Time Contstant L/R < 15ms
Rated operation current le DC
24V 120A 130A 160A 200A
60V 60A 60A 85A 110A
110V 1.8A 1.8A 2A 2.5A
1 pole
220V 0.25A 0.25A 0.5A 0.5A

Utilization Category DC3 & DC5 Type 9B K1-09D 9B K1-12D 9B K3 10ND 9B K3 14ND 9B K3 18ND 9B K3 22ND 9B K3 24A 9B K3 32A 9B K3 40A 9B K3 50A
Switching of Inductive load
Time Contstant L/R < 15ms
Rated operation current le DC
24V 20A 20A 20A 25A 32A 32A 50A 65A 80A 110A
60V 20A 20A 20A 25A 32A 32A 40A 40A 40A 80A
110V 20A 20A 20A 20A 20A 20A 40A 40A 40A 80A
3 poles In Series
220V 2A 2A 2.5A 2.5A 2.5A 2.5A 4A 4A 4A 5A

Utilization Category DC3 & DC5 Type 9B K3 62A 9B K3 74A 9B K3 90A 9B K3 115A
Switching of Inductive load
Time Contstant L/R < 15ms
Rated operation current le DC
24V 120A 130A 160A 200A
60V 80A 80A 100A 110A
60V 80A 80A 100A 110A
3 poles In Series
220V 5A 5A 7A 8A

13
3 Poles Reversing Contactor
• AC3 rated 4KW to 75KW
• For Motor Control
• Compact and space saving design
• Consist of 2 contactors fitted with Mechanical Interlock

AC3 ( Motor ) AC3 400V Auxiliary Contact


380-415V Rated Current Type
kW A NO NC
*230Vac Coil Voltage
(220V-240Vac)
4 10 2 2 9B K3-WU10 A230 SIS 0001 AC Coil Voltage Coding
Code Volts Volts
5.5 14 2 2 9B K3-WU14 A230 SIS 0001 50Hz 60Hz
A024 22-24V 22-27V

7.5 18 2 2 9B K3-WU18 A230 SIS 0001 A042 42-47V 47-52V

A110 100-110V 110-122V

11 22 2 2 9B K3-WU22 A230 SIS 0001 A127 122-135V 135-150V

A230 220-240V 230-264V

15 32 2 2 9B K3-WU32 A230 SIS 0001 A400 380-415V 400-460V

18.5 40 2 2 9B K3-WU40 A230 SIS 0001


DC Coil Voltage Coding
22 50 2 2 9B K3-WU50 A230 SIS 0001 Code Volts
D024 24Vdc

30 62 2 2 9B K3-WU62 A230 SIS 0001 D048 48Vdc

D110 110Vdc

37 74 2 2 9B K3-WU74 A230 SIS 0001 D220 220Vdc

45 90 2 2 9B K3-WU90 A230 SIS 0001 *Other coil voltages


Please consult us.

55 115 2 2 9B K3-WU115 A230 SIS 0001

Accessories
Type Contact
Auxiliary Contact Block - Top Mounted 9B HN10 1NO
for contactors K3-10 to K3-115 9B HN01 1NC
AC1(690) = 10A 9B HN10U 1NO Early make
AC15 (230V) = 3A 9B HN01U 1NC Late Break

Type Contact
Auxiliary Contact Block - Side Mounted 9B HB11 1NO + 1NC
for contactors K3-24 to K3-115 9B HN02 2NC
AC1(690) = 10A
AC15 (230V) = 3A

Type Contact
Auxiliary Contact Block 9B HKT11 1NO + 1NC
for contactors K3-116 to K3-316 9B HKT22 2NO + 2NC
AC1(690) = 10A
AC15 (230V) = 3A 9B HKA11 1NO + 1NC

HKT11 (Top Mounted) HKA11 (Side Mounted)

14
Modular Contactors
• AC1 rated 20A to 63A
• Compact module and space saving
• Low switching noise & hum free
• Low power consumption, sealed
• For use in Distribution Board 45mm
• For application such as controlling small pumps ventilations, lighting systems, heating system etc.
• Suitable for switching lamps such as Incandescent, Fluroescent, Mecury-Vapour, Sodium vapour and Metal Halide
AC1 400V Main Contact Type
Rated Current
A NO NC * 230Vac coil voltage
(220V-240Vac)
1pole (1 module 17.5mm)
20 1 - 9B R20-10 A230
2pole (1 module 17.5mm)
20 2 - 9B R20-20 A230
20 1 1 9B R20-11 A230
20 - 2 9B R20-02 A230
2pole (1 module 17.5mm)
25 2 - 9B R25-20 A230
25 1 1 9B R25-11 A230
25 - 2 9B R25-02 A230
4pole (2 module 35mm)
25 4 - 9B R25-40 A230
25 3 1 9B R25-31 A230
25 1 3 9B R25-13 A230
25 2 2 9B R25-22 A230
25 - 4 9B R25-04 A230
4pole (3 module 52.5 mm)
40 4 - 9B R40-40 A230
40 3 1 9B R40-31 A230
40 1 3 9B R40-13 A230
40 2 2 9B R40-22 A230
40 - 4 9B R40-04 A230
4pole (3 module 52.5 mm)
63 4 - 9B R63-40 A230
63 3 1 9B R63-31 A230
63 1 3 9B R63-13 A230
63 2 2 9B R63-22 A230
63 - 4 9B R63-04 A230

Accessories

1NO + 1NC Auxiliary Contact Block 1/2 Module (8.8mm)


9B RH11
For Modular Contactor R25 (4P) , R40 and R63 (Max. 1pc)
RC-Unit 2x for R20 to R63 9B RC-R230
12V to 250Vac
220nF/100 Ohm
Spacer piece 1/2 Module (8.8mm) for R20.. TO R63 9B P730
Coil Voltage AC 24V. Please consult us.

15
D.O.L Starters in Thermoplastic Enclosure
• Starter for motor control • Include Start/Stop pushbutton
• 0.06kW to 11kW with 3 -phase thermal overload relay with 3 pro- • Supplied with Thermal Overload Relay fitted
tected phases
• Weather Proof Enclosures IP 65 rated up to 11kW (191 x 89 x 101mm
box size)
Motor 3- phase Setting Range of Type
Power Rating 50/60Hz Thermal Overload
AC3 Relay
400V
kW A *Coil =400Vac
(380V-440Vac)
0.06 0.18-0.27 9B P1T10 A400 SIS0002
0.09 0.27-0.4 9B P1T10 A400 SIS0004 Option-with Run Indication Light
0.12 0.4-0.6 9B P1T10 A400 SIS0006
0.18 0.6-0.9 9B P1T10 A400 SIS0009
0.25 0.8-1.2 9B P1T10 A400 SIS0012
0.37 1.2-1.8 9B P1T10 A400 SIS0018
0.55 1.2-1.8 9B P1T10 A400 SIS0018
0.75 1.8-2.7 9B P1T10 A400 SIS0027
1.10 1.8-2.7 9B P1T10 A400 SIS0027
1.50 2.7-4 9B P1T10 A400 SIS0040
2.20 4-6 9B P1T10 A400 SIS0060
3.00 6-9 9B P1T10 A400 SIS0090
3.70 8-11 9B P1T10 A400 SIS0110 Wiring Control Circuits Diagram
4.00 8-11 9B P1T10 A400 SIS0110 For P1T10 & P1T18 & PT122

5.50 10-14 9B P1T18 A400 SIS0140 * Coil voltage 230Vac - Code A230
7.50 13-18 9B P1T18 A400 SIS0180 * Other Thermal overload range and coil voltages
please consult us.
* Option of fitting Run Indication light. (Ordering kits:
11.00 17-23 9B P1T22 A400 SIS0230 9B K2-INR & 9B LG9743R)

Star-Delta Starters in Steel Enclosure


• Starter for motor control
• 5.5KW to 55kW with 3 -phase thermal overload relay with 3 protected phases
• Include 1 green Start and 1 red Stop pushbutton
• Include 1 Green Indicating Run Light and 1 Yellow Indicating Trip Light (400Vac Coil)
• Star Delta Timer and Mechanical Interlock fitted
• Include Thermal Overload Relay Standard with 400V coil Option-with AOM selector switch

Motor 3- phase Motor 3- phase Setting Range Type Type Type Enclosure
Power Rating Current Rating Y-D
Size
50/60Hz 50/60Hz Thermal
AC3 AC3 Overload *Coil =400Vac *Coil =230Vac *Coil =230Vac (mm)
400V 400V Relay fitted with Auto-Off-Manual
(L x W x D)
kW A A selector switch

(380V-440Vac) (220V-240Vac)

5.50 11.5 6-9 9B K3-Y14 BT A400/9 9B K3-Y14 BT A230/9 9B K3-Y14 BTAOM A230/9 300x250x180

7.50 15.5 8-11 9B K3-Y18 BT A400/11 9B K3-Y18 BT A230/11 9B K3-Y18 BTAOM A230/11 300x250x180

11.00 22 10-14 9B K3-Y22 BT A400/14 9B K3-Y22 BT A230/14 9B K3-Y22 BTAOM A230/14 300x250x180

15.00 30 13-18 9B K3-Y32 BT A400/18 9B K3-Y32 BT A230/18 9B K3-Y32 BTAOM A230/18 300x250x180

18.50 37 17-23 9B K3-Y40 BT A400/23 9B K3-Y40 BT A230/23 9B K3-Y40 BTAOM A230/23 400x300x180

22.00 44 20-28 9B K3-Y50 BT A400/28 9B K3-Y50 BT A230/28 9B K3-Y50 BTAOM A230/28 400x300x180

30.00 60 28-42 9B K3-Y62 BT A400/42 9B K3-Y62 BT A230/42 9B K3-Y62 BTAOM A230/42 400x300x180

37.00 72 40-52 9B K3-Y74 BT A400/52 9B K3-Y74 BT A230/52 9B K3-Y74 BTAOM A230/52 500x400x200

45.00 85 40-52 9B K3-Y90 BT A400/52 9B K3-Y90 BT A230/52 9B K3-Y90 BTAOM A230/52 500x400x200

55.00 105 52-65 9B K3-Y115 BT A400/65 9B K3-Y115 BT A230/65 9B K3-Y115 BTAOM A230/65 500x400x200

* Coil Voltage 230Vac-CodeA230


* Other Thermal overload range and coil voltages please consult us.
16 * Weatherproof Thermoplastic IP 65 or Steel IP 65 enclosures available on request.
Open Type Star-Delta Motor Starter Selection Option
• AC3 rated 4KW to 55KW
• Sub-assembley by customer

AC3 ( Motor ) AC3 400V Main Delta Star Thermal Overload Thermal Overload Mechanical
380-415V Rated Current Contactor c/w Contactor c/w Contactor c/w To be fitted on Range Interlock
kW A 1NO+1NC aux. 1NC aux. 2NO+1NC aux. Delta Y D (Ampere) between Star & Delta
4 8.5 9B K3-10ND 10 A230 SIS0001 9B K3-10ND 01 A230 9B K3-10ND 10 A230 SIS0011 9B U12/16E6 7-10.5 9B LG10889

5.5 11.5 9B K3-10ND 10 A230 SIS 0001 9B K3-10ND 01 A230 9B K3-10ND 10 A230 SIS0011 9B U12/16E9 10.5-15.5 9B LG10889

7.5 15.5 9B K3-10ND 10 A230 SIS 0001 9B K3-10ND 01 A230 9B K3-10ND 10 A230 SIS0011 9B U12/16E11 14-19 9B LG10889

11 22 9B K3-14ND 10 A230 SIS 0001 9B K3-14ND 01 A230 9B K3-10ND 10 A230 SIS0011 9B U12/16E14 18-24 9B LG10889

15 30 9B K3-18ND 10 A230 SIS 0001 9B K3-18ND 01 A230 9B K3-14ND 10 A230 SIS 0011 9B U12/16E18 23-31 9B LG10889

18.5 37 9B K3-22ND 10 A230 SIS 0001 9B K3-22ND 01 A230 9B K3-18ND 10 A230 SIS 0011 9B U12/16E23 30-40 9B LG10889

22 44 9B K3-32A 00 A230 SIS 0011 9B K3-32A 00 A230 SIS0001 9B K3-22ND 10 A230 SIS 0011 9B U3/4228 35-48 9B LG10889

30 60 9B K3-40A 00 A230 SIS 0011 9B K3-40A 00 A230 SIS0001 9B K3-32A 00 A230 SIS 0021 9B U3/4242 48-73 9B LG10889

37 72 9B K3-50A 00 A230 SIS 0011 9B K3-50A 00 A230 SIS0001 9B K3-40A 00 A230 SIS 0021 9B U3/7452 70-90 9B LG10890

45 85 9B K3-62A 00 A230 SIS 0011 9B K3-62A 00 A230 SIS0001 9B K3-50A 00 A230 SIS 0021 9B U3/7452 70-90 9B LG10890

55 105 9B K3-74A 00 A230 SIS 0011 9B K3-74A 00 A230 SIS0001 9B K3-50A 00 A230 SIS 0021 9B U3/7465 90-112 9B LG10890

AC Coil Voltage Coding DC Coil Voltage Coding


Code Volts Code Volts
A024 24v 50Hz D012 24Vdc
A042 42v 50Hz D048 48Vdc Mechanical Interlock Specific Timer for Star-Delta changeover
A110 110v 50Hz/120v 60Hz D110 110Vdc
A230 220v-240v 50Hz D220 220Vdc
A400 380-415V 50Hz

Other Thermal Overload ange and Coil Voltages, Please consult us.

17
Capacitor Switching Contactors
for use with reactive or non-reactive capacitor banks
Rated Operational Power at 50/60Hz Aux. Type Coil voltage 1)
Ambient Temperature Contacts 220-240V
50°C 60°C Built-in Add. 50Hz
380V 415V 660V 380V 415V 660V
400V 440V 690V 400V 440V 690V
kVAr kVAr kVAr kVAr kVAr kVAr NO NC pcs.
0-12.5 0-13 0-20 0-12.5 0-13 0-20 1 - 12) 9B K3-18NK10A230 A230
0-12.5 0-13 0-20 0-12.5 0-13 0-20 - 1 12) 9B K3-18NK01A230 A230
10-20 10.5-22 17-33 10-20 10.5-22 17-33 - - 33) 9B K3-24K00A230 A230
10-25 10.5-27 17-41 10-25 10.5-27 17-41 - - 9B K3-32K00A230 A230
20-33.3 23-36 36-55 20-33.3 23-36 36-55 - - 33) 9B K3-50K00A230 A230
20-50 23-53 36-82 20-50 23-53 36-82 - - 9B K3-62K00A230 A230
20-754) 23-754) 36-1204) 20-60 23-64 36-100 - - 9B K3-74K00A230 A230
33-80 36-82 57-120 33-75 36-77 57-120 - - 65) 9B K3-90K00A230 A230
33-100 6) 36-1036) 57-1486) 33-90 6) 36-936) 57-1486) - - 9B K3-115K00A230 A230

Specification: Contactors K3-..K are suitable for switching low-inductive and low loss capacitors in capacitor banks
(IEC70 and 831, VDE 0560) without and with reactors.
Capacitor switching contactors are fitted with early make contacts and damping resistors, to reduce the value of make current <70 x Ie.

Operating Conditions: Capacitor switching contactors are protected against contact welding for a
prospective making current of 200 x Ie.

Technical Data acc. to IEC 947-4-1, IEC 947-5-1, EN 60947-4-1, EN 60947-5-1, VDE 0660

Type 9B K3-18NK 9B K3-24K 9B K3-32K ZBK3-50K 9B K3-62K 9B K3-74K 9B K3-90K 9B K3-115K

Max. frequency of operations z 1/h 120 120 120 120 120 80 80 80

Contact life non reactive capacitor banks S x 103 250 150 150 150 150 120 120 120
reactive capacitor banks S x 103 400 300 300 300 300 200 200 200

Rated operational current Ie at 50°C A 0-18 14-28 14-36 30-48 30-72 30-108 50-115 50-144
AC6b at 60°C A 0-18 14-28 14-36 30-48 30-72 30-87 50-108 50-130

Rated operational current Ith at 50°C A 32 45 60 100 110 120 155 190
AC1 at 60°C A 32 40 55 90 100 110 145 170

Overload factor at 50°C % 78 60 67 108 53 11 35 32


acc. to EN 61921: 30% min. at 60°C % 78 43 53 88 39 26 34 31

Fuses gL (gG) from / to A 35 / 63 50 / 80 63 / 100 80 / 160 125 / 160 160 / 200 160 / 200 160 / 250

Wiring Diagram for


Typical Quick Discharge Resistors
Circuit Diagram Make sure that the current of the discharge
resistors is not higher than the rated current
(AC1) of the auxiliary contacts.

Mounting instructions:
In the area of capacitor switching contactors,
difficulty inflammable and self-extinguishing
materials shall be used only, because
abnormal temperatures within the area of the
resistor spirals cannot be excluded.
1) Other coil voltages, please contact us 4) Consider the max. thermal current of the contactor K3-74A: Ith 130A
2) 1 HN.. snap-on auxiliary 5) 2 HB.. on the left or right side and 4 HN..snap-on auxiliary
3) 2HB.. for side mounting and 1 HN.. snap-on auxiliary 6) Consider the min. cross-section of conductor at max. load

K3-24K & K3-32K

K3-18NK K3-50K
K3-62K
K3-74K

18
K3-90K & K3-115K
Approximate Values for three-phase Motors
Motor Full Load Currents
Approximate values of motor F.L.C. and minimum "slow blow" respectively "gL" short-circuit fuse
Motor Range 220-230V Value 240V Value 380-400V Value 415V Value 500V Value 660-690V Value
rating according to Motor of fusing at Motor of fusing at Motor of fusing at Motor of fusing at Motor of fusing at Motor of fusing at
BS for motor start motor start motor start motor start motor start motor start
415V F.L.C. D.O.L. YD F.L.C. D.O.L. YD F.L.C. D.O.L. YD F.L.C. D.O.L. YD F.L.C. D.O.L. YD F.L.C. D.O.L. YD F.L.C.
kW PS~hp hp cos % A A A A A A A A A A A A A A A A A A
0.06 0.08 - 0.7 59 0.38 1 1 0.35 1 1 0.22 1 1 - - - 0.16 1 1 - - -
0.09 0.12 - 0.7 60 0.55 2 2 0.5 2 2 0.33 1 1 - - - 0.24 1 1 - - -
0.12 0.16 - 0.7 61 0.76 2 2 0.68 2 2 0.42 2 2 - - - 0.33 1 1 - - -
0.18 0.24 - 0.7 61 1.1 2 2 1 2 2 0.64 2 2 - - - 0.46 1 1 - - -
0.25 0.34 - 0.7 62 1.4 4 2 1.38 4 2 0.88 2 2 - - - 0.59 2 2 - - -
0.37 0.5 - 0.72 64 2.1 4 4 1.93 4 4 1.22 4 2 - - - 0.85 2 2 0.7 2 2
0.55 0.75 - 0.75 69 2.7 4 4 2.3 4 4 1.5 4 2 - - - 1.2 4 2 0.9 2 2
0.75 1 1 0.8 74 3.3 6 4 3.1 6 4 2 4 4 2 4 4 1.48 4 2 1.1 2 2
1.1 1.5 1.5 0.83 77 4.9 10 6 4.1 6 6 2.6 4 4 2.5 4 4 2.1 4 4 1.5 4 2
1.5 2 2 0.83 78 6.2 10 10 5.6 10 10 3.5 6 4 3.5 6 4 2.6 4 4 2 4 4
2.2 3 3 0.83 81 8.7 16 10 7.9 16 10 5 10 6 5 10 6 3.8 6 6 2.9 6 4
2.5 3.4 - 0.83 81 9.8 16 16 8.9 16 10 5.7 10 10 - - - 4.3 6 6 - - -
3 4 4 0.84 81 11.6 20 16 10.6 20 16 6.6 16 10 6.5 16 10 5.1 10 10 3.5 6 4
3.7 5 5 0.84 82 14.2 25 20 13 25 16 8.2 16 10 7.5 16 10 6.2 16 10 - - -
4 5.5 - 0.84 82 15.3 25 20 14 25 20 8.5 16 10 - - - 6.5 16 10 4.9 10 6
5.5 7.5 7.5 0.85 83 20.6 35 25 18.9 35 25 11.5 20 16 11 20 16 8.9 16 10 6.7 16 10
7.5 10 10 0.86 85 27.4 35 35 24.8 35 35 15.5 25 20 14 25 16 11.9 20 16 9 16 10
8 11 - 0.86 85 28.8 50 35 26.4 35 35 16.7 25 20 - - - 12.7 20 16 - - -
11 15 15 0.86 87 39.2 63 50 35.3 50 50 22 35 25 21 35 25 16.7 25 20 13 25 16
12.5 17 - 0.86 87 43.8 63 50 40.2 63 50 25 35 35 - - - 19 35 25 - - -
15 20 20 0.86 87 52.6 80 63 48.2 80 63 30 50 35 28 35 35 22.5 35 25 17.5 25 20
18.5 25 25 0.86 88 64.9 100 80 58.7 80 63 37 63 50 35 50 50 28.5 50 35 21 35 25
20 27 - 0.86 88 69.3 100 80 63.4 80 80 40 63 50 - - - 30.6 50 35 - - -
22 30 30 0.87 89 75.2 100 80 68 100 80 44 63 50 40 63 50 33 50 50 25 35 35
25 34 - 0.87 89 84.4 125 100 77.2 100 100 50 80 63 - - - 38 63 50 - - -
30 40 40 0.87 90 101 125 125 92.7 125 100 60 80 63 55 80 63 44 63 50 33 50 35
37 50 50 0.87 90 124 160 160 114 160 125 72 100 80 66 100 80 54 80 63 42 63 50
40 54 - 0.87 90 134 160 160 123 160 160 79 100 100 - - - 60 80 63 - - -
45 60 60 0.88 91 150 200 160 136 200 160 85 125 100 80 100 100 64,5 100 80 49 63 63
51 70 - 0.88 91 168 200 200 154 200 200 97 125 100 - - - 73,7 100 80 - - -
55 75 - 0.88 91 181 250 200 166 200 200 105 160 125 - - - 79 125 100 60 80 63
59 80 80 0.88 91 194 250 250 178 250 200 112 160 125 105 160 125 85,3 125 100 - - -
75 100 100 0.88 91 245 315 250 226 315 250 140 200 160 135 200 160 106 160 125 82 125 100
90 125 125 0.88 92 292 400 315 268 315 315 170 250 200 165 200 200 128 160 160 98 125 125
110 150 150 0.88 92 358 500 400 327 400 400 205 250 250 200 250 250 156 200 200 118 160 125
129 175 175 0.88 92 420 500 500 384 500 400 242 315 250 230 315 250 184 250 200 - - -
132 180 - 0.88 92 425 500 500 393 500 500 245 315 250 - - - 186 250 200 140 200 160
147 200 200 0.88 93 472 630 630 432 630 500 273 315 315 260 315 315 207 250 250 - - -
160 220 - 0.88 93 502 630 630 471 630 630 295 400 315 - - - 220 315 250 170 200 200
184 250 250 0.88 93 590 800 630 541 630 630 340 400 400 325 400 400 259 315 315 - - -
200 270 - 0.88 93 626 800 800 589 800 630 370 500 400 - - - 278 315 315 215 250 250
220 300 300 0.88 93 700 1000 800 647 800 800 408 500 500 385 500 400 310 400 400 - - -
250 340 - 0.88 93 803 1000 1000 736 1000 800 460 630 500 - - - 353 500 400 268 315 315
257 350 350 0.88 93 826 1000 1000 756 1000 800 475 630 630 450 630 500 363 500 400 - - -
295 400 400 0.88 93 948 1250 1000 868 1000 1000 546 800 630 500 630 630 416 500 500 - - -
315 430 - 0.88 93 990 1250 1250 927 1250 1000 580 800 630 - - - 445 630 500 337 400 400
355 483 - 0.89 95 - - - - - - 636 800 800 - - - 483 630 630 366 500 400
400 545 - 0.89 96 - - - - - - 710 1000 800 - - - 538 630 630 410 500 500

The motor F.L.C. be valid for standard internal and surface cooled three-pole motors with current and / or longer starting time, larger short-circuit fuses are required.
1500 min-1. The fuses values be valid for the motor F.L.C. shown in the table and D.O.L.-start: The maximum admissible value is dependent on the switchgear respectively thermal
starting current max. 6x motor F.L.C., starting time max. 5s; star-delta-start: starting current overload relay.
max. 2x motor F.L.C., starting time max. 15s. For motors with higher F.L.C., higher starting

Approximate values of motor F.L.C. according to CSA and UL


Motor Motor F.L.C. at 110-120V Motor F.L.C. at 220-240V1) Motor F.L.C. at 440-480V Motor F.L.C. at 550-600V
rating 1-phase 2-phase 3-phase 1-phase 2-phase 3-phase 1-phase 2-phase 3-phase 1-phase 2-phase 3-phase
hp A A A A A A A A A A A A

1/2 9.8 4.0 4.4 4.9 2.0 2.2 2.5 1.0 1.1 2.0 0.8 0.9
3/4 13.8 4.8 6.4 6.9 2.4 3.2 3.5 1.2 1.6 2.8 1.0 1.3
1 16.0 6.4 8.4 8.0 3.2 4.2 4.0 1.6 2.1 3.2 1.3 1.7
1-1/2 20.0 9.0 12.0 10.0 4.5 6.0 5.0 2.3 3.0 4.0 1.8 2.4
2 24.0 11.8 13.6 12.0 5.9 6.8 6.0 3.0 3.4 4.8 2.4 2.7
3 34.0 16.6 19.2 17.0 8.3 9.6 8.5 4.2 4.8 6.8 3.3 3.9
5 56.0 26.4 30.4 28.0 13.2 15.2 14.0 6.6 7.6 11.2 5.3 6.1
7-1/2 80.0 38.0 44.0 40.0 19.0 22.0 21.0 9.0 11.0 16.0 8.0 9.0
10 100.0 48.0 56.0 50.0 24.0 28.0 26.0 12.0 14.0 20.0 10.0 11.0
15 135.0 72.0 84.0 68.0 36.0 42.0 34.0 18.0 21.0 27.0 14.0 17.0
20 - 94.0 108.0 88.0 47.0 54.0 44.0 23.0 27.0 35.0 19.0 22.0
25 - 118.0 136.0 110.0 59.0 68.0 55.0 29.0 34.0 44.0 24.0 27.0
30 - 138.0 160.0 136.0 69.0 80.0 68.0 35.0 40.0 54.0 28.0 32.0
40 - 180.0 208.0 176.0 90.0 104.0 88.0 45.0 52.0 70.0 36.0 41.0
50 - 226.0 260.0 216.0 113.0 130.0 108.0 56.0 65.0 86.0 45.0 52.0
60 - - - - 133.0 145.0 - 67.0 77.0 - 53.0 62.0
75 - - - - 166.0 192.0 - 83.0 96.0 - 66.0 77.0
100 - - - - 218.0 248.0 - 109.0 124.0 - 87.0 99.0
125 - - - - - 312.0 - 135.0 156.0 - 108.0 125.0
150 - - - - - 360.0 - 156.0 180.0 - 125.0 144.0
200 - - - - - 480.0 - 208.0 240.0 - 167.0 192.0
250 - - - - - 602.0 - - 302.0 - - 242.0
300 - - - - - - - - 361.0 - - 289.0
350 - - - - - - - - 414.0 - - 336.0
400 - - - - - - - - 477.0 - - 382.0
500 - - - - - - - - 590.0 - - 472.0

1) Determine the motor current for 200V and 208V by increasing the values for 220-240V at 200V about 15% and for 208V about 10%.

19
Mini-Reversing Contactor for motor control Mini-Contactor PCB mounting and Solder Pins
PCB mounting and Screw Termination Termination

Mini-Contactor Din rail and Fast On Tab Mini-Reversing Contactor for motor control
Connector Termination Din Rail and Screw Termination

Contactor with Latch (K1-L2) option - to keep Aux.Contact HN....


contactor mechanically closed even after • Bifurcated contact design - 4 contact
power failures. points
• By moving the length (contact point
distance) of straight to bended contact
bridge - relative movement will clean
contact surface.
• Suitable for used in low voltage electronic
circuit. (17mV, 15mA)

RC- Units protect the contactor coils against


voltage peaks & harmonic waves.

SINGAPORE (Head Office) MIDDLE EAST (Branch Office)


Kraus & Naimer Pte. Ltd. Kraus & Naimer Pte. Ltd.
115A Commonwealth Drive SaIF Zone, P.O. Box: 121607
#03-17/23, SHAJAH - UAE
SINGAPORE 149596 Tel : 971 6 5578886
Tel : (65) 64738166 Fax : 971 6 5578088
Fax : (65) 64738643 e-mail : [email protected]
e-mail : [email protected]
LICENSE NO: 03-03-07159
COMPANY REG NO: 196600227Z

999 BJBrochure/SGX1189 PD.01/13


Our company’s policy is one of continuous development and improvement and therefore, the products shown in this catalogue can be subjected to change in
appearance, characteristic, operation and utilisation. The details given are for guidance only and shall not bind us in any way.