Length of U shaped Wall = 8 m

Breadth of U shaped Wall = 6 m


Height of U shaped Wall = 7 m

Loads
Dead load = Self Weigh as per Staad
Denisty of Soil = 21 kN/cum
Denisty of Concrete = 25 kN/cum

Vertical Traffic load assumed on base = 20 kN/sqm


Vertical Soil load on base -DL = 147 kN/sqm

Coefficient of Soil = 0.5


Surcharge load of Traffic load on wall = 10 kN/m
Soil load on wall - DL = 73.5 kN/sqm

Soil Spring
SBC at the dept of 1.5 mt from NGL/FGL = 150 kn/sqm
Settlement considered = 0.025 m
Spring = 6000

Load & combination

DL = Self weight + Vertical soil weight


of heal of raft + Hor triangulat load on
on Wall

LL = Vertical traffic load


of heal of raft + Hor uniform load on
on Wall

DL+ LL
1.2 (DL + LL)
1.5 (DL + LL)
8

Bowel = 40 x factor of safety x SBC


= 18000