0% found this document useful (0 votes)
72 views1 page

Similar To Belden 9841 2 Conductor 24 Awg Stranded Overall Shield / Braid Type CM

This document provides specifications for Paige cable part number 459841, which is a 2-conductor 24 AWG stranded cable with an overall aluminum mylar shield, tinned copper braid, and a gray PVC jacket. Key details include the cable construction of tinned copper conductors with low density polyethylene insulation and its electrical properties like a capacitance of 12.8 pF/ft between conductors and 23 pF/ft from conductor to shield. The cable is RoHS compliant and rated for 300V under the CM rating or 30V under the AWM 2919 rating.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
72 views1 page

Similar To Belden 9841 2 Conductor 24 Awg Stranded Overall Shield / Braid Type CM

This document provides specifications for Paige cable part number 459841, which is a 2-conductor 24 AWG stranded cable with an overall aluminum mylar shield, tinned copper braid, and a gray PVC jacket. Key details include the cable construction of tinned copper conductors with low density polyethylene insulation and its electrical properties like a capacitance of 12.8 pF/ft between conductors and 23 pF/ft from conductor to shield. The cable is RoHS compliant and rated for 300V under the CM rating or 30V under the AWM 2919 rating.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

spec

908-687-7810, 800-327-2443, Fax: 908-687-8860 www.paigeelectric.com

459841

Similar to Belden 9841


2 CONDUCTOR 24 AWG STRANDED
OVERALL SHIELD / BRAID
TYPE CM.

1.0 SCOPE: 2.5 DRAIN:


1.1 This cable consists of 2 conductor 24 2.5.1 Material: Tinned Copper
AWG stranded tinned copper; color- 2.5.2 Size: 24 AWG
coded low density Polyethylene 2.5.3 Construction: 7 Strand
insulation; overall aluminum mylar
shield with drain wire; tinned copper 2.6 BRAID:
braid; overall PVC jacket. 2.6.1 Material: Tinned Copper
2.6.2 Size: 36 AWG
RoHS Compliant 2.6.3 Coverage: 90%

2.0 CONSTRUCTION: 2.7 JACKET:


2.1 CONDUCTOR: 2.7.1 Material: Sunlight Resistant PVC
2.1.1 Material: Tinned Copper 2.7.2 Wall Thickness: .035”
2.1.2 Size: 24 AWG 2.7.3 OD: .232” nom.
2.1.3 Construction: 7 Strand 2.7.4 Color: Gray
2.7.5 Ripcord: No
2.2 INSULATION: 2.7.6 Markings: PAIGE #459841 E191596
2.2.1 Material: Low Density 24AWG 2C SHLD (UL) CM c(UL)us 75C
Polyethylene OR AWM STYLE 2919 80C 30V LOW
2.2.2 Wall Thickness: .023” VOLTAGE COMPUTER CABLE ROHS II
2.2.3 Color code: COMPLIANT REACH MADE IN USA
White/Blue (Ascending/Descending footage
Blue/White markings)

2.3 CABLING OVERALL LAY: 2.8 ELECTRICALS:


2.3.1 2 ½” left hand lay 2.8.1 Capacitance: (CDR-CDR) 12.8 pF/ft.
(CDR-SHLD) 23 pF/ft.
2.4 SHIELD: 2.8.2 Impedance: 120 ohms
2.4.1 Material: Aluminum Mylar 2.8.3 Velocity of Propagation: 66%
2.8.4 Nominal Delay: 1.6 ns/ft.
2.8.5 DC Resistance: 24 ohms/1000 ft. @20oC
2.8.6 Outer Shield DC Resistance: 3.4 Ohms
/1000 ft.
2.8.7 Attenuation: 0.6 dB/100 ft. @ 1 MHz
2.8.8 Voltage Rating (CM): 300V
2.8.9 Voltage Rating (AWM 2919): 30V

The information and specifications described herein are subject to error or omission and to change without notice.

Paige provides the information and specifications herein on an “AS IS” basis, with no representations or warranties, whether express, statutory or implied. In no event will
Paige be liable for any damages (including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Paige has been advised
of the possibility of such damages, whether in an action under contract, negligence or any other theory, arising out of or in connection with the use, or inability to use,
the information or specifications described herein.

459841-A Rev 1 7/6/17