Service Manual: Back To Section Table of Contents
Service Manual: Back To Section Table of Contents
Service Manual: Back To Section Table of Contents
TABLE OF CONTENTS
HYDRAULIC PUMPS LOCATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
A3V VARIABLE DISPLACEMENT PUMP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
FIXED DISPLACEMENT PUMP A2FO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
REXROTH / HYDROMATIK MODEL A7V SERIES 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
REXROTH / HYDROMATIK MODEL A7V SERIES 6 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
REXROTH / HYDROMATIK MODEL A10VO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18
REXROTH / HYDROMATIK MODEL A11VO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20
LINDE HYDRAULIK BPR 105 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24
VOAC VARIABLE DISPLACEMENT AXIAL PISTON PUMP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .27
PumpKit Pumps
PumpKit Pumps
Agitator Pump
Accumulator Pump
Stiebel 4400
Page 1
Back to Section Table of Contents
2000 SERVICE MANUAL
HYDRAULIC PUMPS
A3V VARIABLE DISPLACEMENT PUMP
Page 2
Back to Section Table of Contents
SERVICE MANUAL 2000
HYDRAULIC PUMPS
A3V VARIABLE DISPLACEMENT PUMP
Qmax Qmin
X X P T U
M2 M1
Z H
K J2 B1 B2
J1
Page 3
Back to Section Table of Contents
2000 SERVICE MANUAL
HYDRAULIC PUMPS
A3V VARIABLE DISPLACEMENT PUMP
The resulting hydraulic power of the two system pressures and the measuring surfaces is summated by the control
piston which is designed as stepped piston. The hydraulic force works against the spring force of the control ele-
ment which is mounted inside of the regulator. As the sum of the pressure increases, the spring is compressed
until the hydraulic and spring forces are equal.
The distance the spring has been compressed is the positioning distance which the pump can be swiveled back via
the coupling and swivel trunnion. As the pressures decrease, the spring swivels the pumps back out to maximum
swivel angle. In order to stabilize the regulator, a sieve protected throttle diaphragm is mounted in the measuring
lines in front of the regulating piston.
In order to achieve as nearly hyperbolic drive characteristics as possible, 2 measuring springs as well as a posi-
tioning distance limiting screw are incorporated in the regulator. The smaller measuring spring is not acted upon
until a certain positioning distance has taken place.
J1 = Measuring Connection Line1
B2 = Pressure Connection2
S = Suction connection
Page 4
Back to Section Table of Contents
SERVICE MANUAL 2000
HYDRAULIC PUMPS
A3V VARIABLE DISPLACEMENT PUMP
p = p 1 + p2
6
5
p max
f1 + f 2
4
Nin
Na
f1
Q1 = Q2
0 Qmin 1 Qmax
Page 5
Back to Section Table of Contents
2000 SERVICE MANUAL
HYDRAULIC PUMPS
A3V VARIABLE DISPLACEMENT PUMP
GE RG R
B1
GK
S
S
B2
GA HA M2 M1
Page 6
Back to Section Table of Contents
SERVICE MANUAL 2000
HYDRAULIC PUMPS
FIXED DISPLACEMENT PUMP A2FO
Fixed displacement axial piston pumps of bent axis design for use in hydrostatic drives in open circuits. The output
flow is proportional to the input speed and the fixed displacement of the pump. The pump is suitable for use in
mobile and industrial applications.
Page 7
Back to Section Table of Contents
2000 SERVICE MANUAL
HYDRAULIC PUMPS
FIXED DISPLACEMENT PUMP A2FO
p max
Pressure at ports A or B 45 (3)
15 (1)
Direction of flow psi (bar) 0 1000 2000 3000
Clockwise rotation ______________________________ S to B
Counter clockwise rotation _______________________ S to A speed n (rpm)
n o max
T Case drain port 1.0 14.5 (1.0)
n
U Bearing flushing port 0.9 12 (0.8)
Speed
T S U 0.8 psi (bar)
Open circuit 0.6 0.7 0.8 0.9 1.0
V
Displacement
Table of values Vg max
Theoretical values, not considering ηmh and ηv; values rounded
Size 250 355 500 1000
Displacement Vg in3 (cm3) 15.25 (250) 21.66 (355) 30.51 (500) 61.02 (1000)
Max. speed 1) n o max
rpm 1500 1320 1200 950
Max. permissible speed with increasing
no max perm. rpm 1800 1580 1440 1140
inlet pressure pabs (see diagram)
Max. output flow Qmax gpm (L/min) 99 (375) 123 (469) 158 (600) 250 (950)
Torque constant Tc lb-ft/psi (Nm/bar) 0.202 (3.98) 0.287 (5.64) 0.404 (7.95) 0.809 (15.90)
Max. torque at Vg max ∅p = 5100 psi (350 bar) T lb-ft (Nm) 1031 (1391) 1463 (1976) 2060 (2783) 4126 (5565)
Max. power at no max. ∅p = 5100 psi (350 bar) P HP (kW) 294 (219) 366 (273) 470 (350) 743 (554)
Moment of inertia (about drive shaft) J lb ft2 (kgm2 ) 1.44 (0.061) 2.42 (0.102) 4.22 (0.178) 13.05 (0.550)
Volume to fill casing gal (L) 0.66 (2.5) 0.92 (3.5) — 2.06 (7.8)
Approx. weight (without fluid) m lbs (kg) 161 (73) 243 (110) 342 (155) 696 (316)
Permissible loading of drive shaft: + Fax max lbf (N) 899 (4000) 1124 (5000) 1405 (6250) —
Max. permissible axial force —Fax max lbf (N) 270 (1200) 337 (1500) 427 (1900) —
Max. permissible radial force Fq max lbf (N) 270 (1200) 337 (1500) 427 (1900) —
1
) The values shown are valid for an absolute pressure (pabs) of 14.5 psi (1 bar) Forces Fq
± Fax
Determination of size
X/2 X/2
Vg ¥ n ¥ η v Vg ¥ n ¥ ηv Vg = Geometric displacement in3 (cm3)
Flow Q=
231
gpm (Q = 1000 )
L/min ∅p = Differential pressure psi (bar) X
Vg ¥ ∅p Vg ¥ ∅p n = Speed rpm
Torque T = lb-ft (T = Nm ) ηv = Volumetric efficiency
24 ¥ ≠ ¥ η mh 20 ¥ ≠ ¥ ηmh ηmh = Mechanical-hydraulic efficiency
T¥n T¥n ηt = Total efficiency (ηtot = ηmh ¥ ηv)
Power P =
5252
HP (P = 9549
kW )
Page 8
Back to Section Table of Contents
SERVICE MANUAL 2000
HYDRAULIC PUMPS
REXROTH / HYDROMATIK MODEL A7V SERIES 2
Note: After replacing any A7VO hydraulic pump, the unit must be bled before start-up.
• If there is a U-Port on the pump, this is the bearing flush and that is where the pump should be bled from.
• If there is not a U-Port, the pump should be bled from the highest case drain.
The flow is proportional to the drive speed and the displacement and is steplessly variable at constant drive speed.
Comprehensive program of control devices for every control and regulating function.
High performance rotary group with well-proven spherical control area offering the following advantages: self-cen-
tering, low peripheral speed, high efficiency.
Page 9
Back to Section Table of Contents
2000 SERVICE MANUAL
HYDRAULIC PUMPS
REXROTH / HYDROMATIK MODEL A7V SERIES 2
Setting range from 50 to 350 bar. Setting range for remote control 50 to 315 bar
max. 10 bar
P max
350
315
300
150
Operating pressure PB (bar)
setting range
200
100
50
0
Flow Q (L/min.)
A (B) R
T
X3 A
S T
Page 1 0
Back to Section Table of Contents
SERVICE MANUAL 2000
HYDRAULIC PUMPS
REXROTH / HYDROMATIK MODEL A7V SERIES 2
X2
G
X1
S
Figure 6 - Schematic of a A7V Variable Displacement Pump With Hydraulic Stroke Limiter
By Means of a mechanical or hydraulic stroke limiter, the maximum displacement can be infinitely varied or limited.
Adjusting range from Vg max to Vg min.
A pilot pressure (port X1) of at least 10% of the operating pressure is required for the hydraulic stroke limiter. Maxi-
mum permissible pressure at port X1 = 200 bar (for all sizes).
If it is required to limit the flow at an operating pressure < 50 bar, then a boost pressure of minimum 50 bar must be
applied at port X2 (at port X1 then, minimum 10% = 5 bar)
Page 1 1
Back to Section Table of Contents
2000 SERVICE MANUAL
HYDRAULIC PUMPS
REXROTH / HYDROMATIK MODEL A7V SERIES 2
Q min
Q max
Page 1 2
Back to Section Table of Contents
SERVICE MANUAL 2000
HYDRAULIC PUMPS
REXROTH / HYDROMATIK MODEL A7V SERIES 6
0ß
25ß -
Page 1 3
Back to Section Table of Contents
2000 SERVICE MANUAL
HYDRAULIC PUMPS
REXROTH / HYDROMATIK MODEL A7V SERIES 6
V = constant
p B = operating pressure
pB g
V = pump displacement
g
350
Operating pressure p B (bar)
300
250
220 bar
200
150 Adjust. range
Start of control
100
50 50 bar
0
0 0.2 0.4 0.6 0.8 1.0
V Displacement V
g min g max
A 1 A (B) R
X3
S T1
Figure 4 - Schematic of a A7VO Variable Displacement Pump
Page 1 4
Back to Section Table of Contents
SERVICE MANUAL 2000
HYDRAULIC PUMPS
REXROTH / HYDROMATIK MODEL A7V SERIES 6
X1
Y3
A
A1
S A7VO-107 LR
Figure 5 - Schematic of a A7VO Variable Displacement Pump With Hydraulic Stroke Limiter
40
35
30
25
pilot press. PSt in bar
20
setting range
15
10
Page 1 5
Back to Section Table of Contents
2000 SERVICE MANUAL
HYDRAULIC PUMPS
REXROTH / HYDROMATIK MODEL A7V SERIES 6
Horsepower
Adjustment
Screw
Q min
0ß
25ß -
Q max
Page 1 6
Back to Section Table of Contents
SERVICE MANUAL 2000
HYDRAULIC PUMPS
REXROTH / HYDROMATIK MODEL A7V SERIES 6
Setting range from 50 to 350 bar. Setting range for remote control 50 to 315 bar
max. 10 bar
P max
350
315
300
150
100
50
0
Flow Q (L/min.)
∆ P regulator
High pressure filters
X
20
A bar ∆ P
A1
290
bar
P
A T
X3
Page 1 7
Back to Section Table of Contents
2000 SERVICE MANUAL
HYDRAULIC PUMPS
REXROTH / HYDROMATIK MODEL A10VO
Page 1 8
Back to Section Table of Contents
SERVICE MANUAL 2000
HYDRAULIC PUMPS
REXROTH / HYDROMATIK MODEL A10VO
DR Pressure Control
The pressure control serves to maintain a constant pressure in the hydraulic system, within the control range of the
oump. The pump therefore supplies only the amount of hydraulic fluid required by the actuators. Pressure may be
smoothly set at the pilot valve.
Page 1 9
Back to Section Table of Contents
2000 SERVICE MANUAL
HYDRAULIC PUMPS
REXROTH / HYDROMATIK MODEL A11VO
Output flow is proportional to drive speed and pump displacement and is steplessly variable between maximum
and zero.
Page 2 0
Back to Section Table of Contents
SERVICE MANUAL 2000
HYDRAULIC PUMPS
REXROTH / HYDROMATIK MODEL A11VO
V = constant
p B = operating pressure
pB g
V = pump displacement
g
350
250
220 bar
200 Setting range
150 Start of control
100
50 50 bar
0
0 0.2 0.4 0.6 0.8 1.0
V Displacement V
g min g max
Operating pressure applies a force on a piston within the control piston on to a rocker arm. An externally adjustable
spring force is applied to the other side of the rocker arm to determine the power setting.
Should the operating pressure exceed the set spring force, the pilot control valve is operated via the rocker arm,
allowing the pump to swivel towards zero output. This in turn reduces the effective moment on the arm of the
rocker, thus allowing the operating pressure to rise in the same ratio by which the output flow is reduced (pB • Vg =
constant).
M A G T1 R T2
Vg max Vg min
s M1
Page 2 1
Back to Section Table of Contents
2000 SERVICE MANUAL
HYDRAULIC PUMPS
REXROTH / HYDROMATIK MODEL A11VO
35
30
25
20
setting range
10
0 0,5 1,0
Vg min Vg Vg max
Displacement Vg max
The hydraulic stroke limiter is overridden by the constant power control, i.e. below the power curve (power hyper-
bola), displacement is adjusted in relation to pilot pressure. If the set flow or the operating pressure is such that the
power curve is exceeded, the constant power control overrides the stroke limiter and reduces displacement until
the power hyperbola is restored.
Vg max Vg min
s M1
Page 2 2
Back to Section Table of Contents
SERVICE MANUAL 2000
HYDRAULIC PUMPS
REXROTH / HYDROMATIK MODEL A11VO
Pressure Cut-Off
Delta P
Q min
Load Sense Port
Q max
Stroke Regulation
Pressure Cut-Off
Horsepower Control
Stroke Regulation
Pressure Cut-Off
Horsepower
Control
Q min
Q min
Page 2 3
Back to Section Table of Contents
2000 SERVICE MANUAL
HYDRAULIC PUMPS
LINDE HYDRAULIK BPR 105
Page 2 4
Back to Section Table of Contents
SERVICE MANUAL 2000
HYDRAULIC PUMPS
LINDE HYDRAULIK BPR 105
P RE
PC
RB
L P P Y
U T
Figure 4 - Schematic of a BPR 105 Variable Displacement Pump With Stroke Limiter
Page 2 5
Back to Section Table of Contents
2000 SERVICE MANUAL
HYDRAULIC PUMPS
LINDE HYDRAULIK BPR 105
L P P Y X
U T
Figure 5 - Schematic of a BPR 105 Variable Displacement Pump With Stroke Limiter
Page 2 6
Back to Section Table of Contents
SERVICE MANUAL 2000
HYDRAULIC PUMPS
VOAC VARIABLE DISPLACEMENT AXIAL PISTON PUMP
Variable displacement pumps work according to the swash plate pricipal: 9 pistons operate in a rotating cylinder
barrel where they fulfill one suction and one presssure stroke per rotaiton. The axial movement of the pistons is
provided by an adjustable swash plate. he setting angle (0-17˚) is varied in proportion to the desired displacement
flow. The setting range can be mechanically limited by setting screws. The position of the swash plate can be con-
trolled via a visual mechanical indicator. The latest knowledge and experience with regard to noise reduction has
been used in the development of V30D. All components used in the V30D are manufactured from high grade mate-
rials and machined with close tolerances.
Q min
Q max
Page 2 7
Back to Section Table of Contents
2000 SERVICE MANUAL
HYDRAULIC PUMPS
VOAC VARIABLE DISPLACEMENT AXIAL PISTON PUMP
Horsepower Control
Q min Q max
Pressure Cut-off
Q min Q max
Pressure Cut-off
VOAC Boom Pump
Page 2 8
Back to Section Table of Contents