100% found this document useful (1 vote)
14K views2 pages

TWS Installation Drawing

The document outlines the procedure for installing an IRS Point Machine with Clamp Lock and Ground Connection arrangement according to RDSO drawing number RDSO/S3454. The procedure involves marking and drilling holes for the Clamp Lock Assembly on the stock rail and tongue rail. It also describes marking and drilling holes for ground connections on the left and right hand sides depending on which side the point machine is connected to. Finally, it mentions drilling holes for Switch extension brackets to connect the ground connections.

Uploaded by

Madhav Prasad
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
100% found this document useful (1 vote)
14K views2 pages

TWS Installation Drawing

The document outlines the procedure for installing an IRS Point Machine with Clamp Lock and Ground Connection arrangement according to RDSO drawing number RDSO/S3454. The procedure involves marking and drilling holes for the Clamp Lock Assembly on the stock rail and tongue rail. It also describes marking and drilling holes for ground connections on the left and right hand sides depending on which side the point machine is connected to. Finally, it mentions drilling holes for Switch extension brackets to connect the ground connections.

Uploaded by

Madhav Prasad
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

Installation of TWS as per RDSO drawing no.

RDSO/S3454

The procedure for IRS Point Machine with Clamp Lock and Ground Connection
arrangement 60 Kg (with Thick Web Switch) as per RDSO as per RDSO DRG. No.
RDSO/S3454 is as follows:
(A) Marking & drilling holes for Clamp Lock Assembly
(a) Stock rail

(b) Tongue rail


(B) Marking & drilling holes for ground connections (Lock and detector rods)
(a) If point machine is connected to Left hand- side.

(b) If point machine is connected to Right hand- side.

(C) Holes for Switch extension brackets (P brackets) to connect ground connections (Lock
and detector rods)