XT Supercapacitors: Snap-In Cylindrical Cells
XT Supercapacitors: Snap-In Cylindrical Cells
XT Supercapacitors: Snap-In Cylindrical Cells
XT Supercapacitors
Snap-in cylindrical cells
HALOGEN Features and benefits
Pb HF
FREE • 3.0 V operating voltage for high power and
energy
• Ultra low ESR for very high power density
• Large capacitance for high energy density
• UL recognized
Applications
• Industrial backup/ridethrough
• Energy storage for UPSs
• Automotive pulse power
• Medical equipment pulse power
Description
Eaton supercapacitors are unique, ultra-high
capacitance devices utilizing electrochemical
double layer capacitor (EDLC) construction
combined with new, high performance materials.
This combination of advanced technologies
allows Eaton to offer a wide variety of capacitor
solutions tailored to specific applications that
range from a few micro-amps for several days to
several amps for seconds.
The XT family advances the energy density by
20% and power density by 10%. These advances
allow longer operating life and/or lower cost
systems.
Technical Data 10762 XT Supercapacitors
Effective February 2018 Snap-in cylindrical cells
Ratings
Capacitance 275 F to 555 F
Working voltage 3.0 V
Surge voltage 3.3 V
Capacitance tolerance -5% to +20% (+20 °C)
Operating temperature range -40 °C to +65 °C
Extended operating temperature range -40 °C to +85 °C (with linear voltage derating to 2.6 V @ +85 °C)
Specifications
Nominal Typical Short
Maximum Continuous Peak leakage Peak Stored thermal circuit
initial ESR1 current6 current5 current2 power4 energy3 resistance7 current**,8
Capacitance1 (F) Part Number (mΩ) (A) (A) (mA) (W) (mWh) Rth (°C/W) (A)
Performance
Capacitance Change ESR
Parameter (% of initial value) (% of initial maximum value)
Lifetime — 1,500 hours at maximum rated voltage and operating temperature ≤ 20% ≤ 200%
Charge/discharge cycling — 500,000 at +20 °C
9
≤ 20% ≤ 200%
Storage, uncharged, up to +35 °C — 3 years ≤ 5% ≤ 10%
1. Capacitance, Equivalent Series Resistance (ESR) and Leakage current are measured according to IEC62391-1.
2. Leakage current at +20 °C after 72 hour charge and hold.
3. Stored Energy (mWh) = 0.5 x C x V2 *1000
3600
4. Peak Power (W) = V2
4 x ESR
5. Peak current for 1 second from full rate voltage to half voltage.(A) = 0.5 x V x C
(1 + ESR x C)
6. Continuous current with a 15 °C temperature rise. Continuous current (A) =
7. Thermal resistance (Rth) cell body temperature to ambient in open air in degrees C per Watt (°C/W).
8. Short circuit current is for safety information only. Do not use as operating current.
9. Cycling between maximum working voltage and half voltage with 3 seconds rest at +20 °C.
2 www.eaton.com/electronics
XT Supercapacitors Technical Data 10762
Snap-in cylindrical cells Effective February 2018
L
Positive Terminal 120.0°
22.50 ± 1.00 6.00 ±1.00
Blank Terminal
For Mechanical Support 24.20 ± 1.00 35.00 ±1.00
Negative Terminal
0.95
PCB Patterns
1.50
4 x 2.0 dia. ± 0.1
Typical
Part Number L (±1.0) Mass (g)
XT3550-3R0287-R 53 62
XT3560-3R0377-R 63 72
XT3585-3R0567-R 87.5 108
XT 3560 –3R0 37 7 -R
www.eaton.com/electronics 3
Technical Data 10762 XT Supercapacitors
Effective February 2018 Snap-in cylindrical cells
Wave solder profile
tp
Tp
Temperature First Wave Second Wave
Tsmax
Tstyp
Tsmin
Time
Manual solder
+350 °C, 4-5 seconds. (by soldering iron), generally manual, hand soldering is not recommended.
Cleaning/Washing
Avoid cleaning of circuit boards, however if the circuit board must be cleaned use static or ultrasonic immersion in a standard circuit board
cleaning fluid for no more than 5 minutes and a maximum temperature of +60 °C. Afterwards thoroughly rinse and dry the circuit boards. In
general, treat supercapacitors in the same manner you would an aluminum electrolytic capacitor.
Life Support Policy: Eaton does not authorize the use of any of its products for use in life support devices or systems without the express written
approval of an officer of the Company. Life support systems are devices which support or sustain life, and whose failure to perform, when properly
used in accordance with instructions for use provided in the labeling, can be reasonably expected to result in significant injury to the user.
Eaton reserves the right, without notice, to change design or construction of any products and to discontinue or limit distribution of any products. Eaton also
reserves the right to change or update, without notice, any technical information contained in this bulletin
Eaton
Electronics Division
1000 Eaton Boulevard
Cleveland, OH 44122
United States
www.eaton.com/electronics
© 2018 Eaton
All Rights Reserved Eaton is a registered trademark.
Printed in USA
Publication No. 10762 BU-MC18002 All other trademarks are property
February 2018 of their respective owners.