(User Manual) USR TCP232 T2 User Mannul
(User Manual) USR TCP232 T2 User Mannul
com
Contents
1. Quick Start
USR-TCP232-T2 is used for data bidirectional transparent transmission between TTL and Ethernet. T2 module itself
complete protocol conversion, parameter can be set by built-in webpage or software. Once set permanent preservation.
This chapter is quick start for using USR-TCP232-T2 module,we advice users to read it carefully and operate personally,
it can help you know about module generally.
Here is application case for inference:
http://www.usriot.com/support/application-case/usr-tcp232-series-application-case/
You can also email it to Customer Support Center:
http://h.usriot.com/
1.2. Connection
To prevent the thing that occur when the custom use it like can not find server, can not ping and can not open the
webpage. After connect you should check the computer before used.
Diagram 1.2-1
2) Shut down network card none-related, reserve one connect.
Diagram 1.2-2
3) If you want to connected module to PC directly, user should set static IP for computer which is in the same
network segment with module.
Diagram 1.2-3
Item Intro
User name admin
Password admin
IP address 192.168.0.7
Target IP 192.168.0.201
1) Install USR-TCP232-Test.exe .
Baud rate:115200
From now, we can perform the send/receive data test. The direction from serial to network is: serial port of PC_> T2
serial port _> T2 ethernet port_>PC. The direction from net work to serial is: PC network _> T2 ethernet port_> T2 serial
port _> serial port of PC
2. Overview
2.2. Features
10/100Mbps can adopted to Ethernet, support AUTO-MDIX switching of network cablle crossovers.
Work mode:TCP server, TCP client, UDP server, UDP client, Httpd client.
Baud of the serial port can edit from 600bps to 460.8Kbps. Support five ways to check including None, Odd, Eben,
Mark, Space.
Customize heartbeat package, keep the connection real and reliable, no crash.
Customize registration package, check the connection status, and also customize the head of package,choose the
MAC address to be the registration package.
In TCP Server mode, the number of client connected can be modify from 1 to 16, default is 4. The IP of connected
client can be see. Send and receive data according to connection calculation.
In TCP Server mode, when the client number reach the max number, the new client can instead of the old one or not
can be set.
Support webpage,AT command, serial port protocol,webpage setting parameter,setting protocol. Provide custom to
use in their own software.
Support TCP client short connection, the time can be set.
Support reset out time, the time can be set.
Before the TCP connect, whether clear the data before can be set.
Support DHCP, get IP automatically
The unique MAC address in the world, and the address can be modify. Support the function of customize MAC.
Support DNS, domain name resolution.
Support customize the address of DNS server.
Support upgrade the firmware from webpage, more convenient.
Support v-com
Support across the gateway, switching and router
Support work in LAN, also can access the external.
RFC2217 Support
Httpd client Support
TCP server Max number of connected TCP is 16(can customize)
Network cache Send: 6Kbyte; receive: 4Kbyte
Serial cache Receive:800byte
Average transport delay <10ms
Others
Certification CE, FCC
Size 50.5*22.6*15.0 mm (L*W*H)
Working temp: -25 ~ 75 °C
Storage temp: -40 ~ 105 °C
Temperature Storage humidity: 5% ~ 95% RH
3. Hardware parameter
2 Link Reserve pin Used as indication pin for TCP connection status.
Refer to 4.4.2 Link Function
3 ISP Reserve pin Hasn’t use
3.1.2. Dimension
Note:
1) RST: Restart button. It works at low level, 3.3V, 10K pull-up resistor inside. When it access to power or
breakdown, pull down 300ms then high level.
2) Link: connection indication.Can be used as indication pin for net connection, when connected, it outputs low
level; When unconnected, it output high level.
3) CFG(Reload): connect to external button or configuration pin. 3.3V, 10K pull-up resistor inside. Press it
and pull to low level, then release hands after 3 seconds, module restores factory default and restart.
4) UART_TXD/RXD: data rend/ receive signal(10K pull-up resistor inside)
USR-TCP232-T2 has dual power supply interface, 5.5 v and 3.3 v (only choose one) Working current 150 mA, max
current 200mA .
VCC: typical value DC 3.3V, 3.15V~3.45 V. It is used for 3.3 V MCU.
VDD: typical value DC 5V, 4.75V~5.5V. When connect to 5V MUC, refer to Diagram 3.2.3 -2 3.3V to 5V voltage
conversion circuit
UART can connect RS232 chip, UART has TXD/RXD signal wire. Take RS232 Level for example.
4. Module function
Here are the function of T2, below is the overall block diagram.
1. IP address is the identity representation of the module in the LAN, which is unique in LAN. So it can not be repeated.
There are two ways to access the network: static IP and DHCP.
Static IP
Static IP need to be setting handy. Meanwhile write the IP, subnet masks and modbus gateway. Static IP can be used
in.
Advantage: can be searched when the device accesses the IP that can not distribute.
Disadvantage: can not communicate if the device in the different port of the different LAN
DHCP
Main function is get the IP address, gateway address, DNS server address from the gateway holder, and no need for
the complex steps. Adopted to the situation have little requirement for IP and do not ask the IP to corresponds to module.
Advantage: access the devices that support DHCP server like router can communication directly. Reduce the trouble of
setting IP address gateway and subnet masks.
Disadvantage: directly to the computer in the net do not support the DHCP server, T2 can not work
2. Subnet masks mainly used to determine the host number and the network number, indicates the number of subnet and
determine the flag within the subnet. The subnet masks needed to set,usually we use the subnet masks: 255.255.255.0,
the network number is the former 24, the holder name is the last 8, number of subnet is 255, the module IP is in the range
of 255, and then we are sure that the module IP is in this subnet.
3. Gateway means the net number of the current IP that module in. If connect the device like router when access the
external, the gateway IP is the router IP, if there is some thing wrong with setting, can not access the external net. If no
need to connect the router, keeping default is ok.
4. Reference AT command
Jinan USR IOT Technology Limited 16 www.usriot.com
USR-TCP232-T2 user manual www.usriot.com
command name Instr
T2 has its own webpage server, same as the normal webpage server, which is convenient for user to setting parameter
and query the status of T2.
The port of webpage can be setting, default is 80.
Steps:
Open the browser, fill the IP of T2, e.g.:192.168.0.7(IP address and PC in the same net.)
Fill the user name and key word in the login webpage, default is admin, click the sure and enter.
Then there is the status webpage:
Webpage upgrade the firmware, stable and simple. Use this new function, meet the custom requirement. If you need
to upgrade, you can query us from the USR support or ask firmware from supply. The way to upgrade please refer the
5.1.1.
The work mode for T2 divide into five: TCP Client、TCP Server、UDP Client、UDP Server、Httpd Client. You can use
webpage and setting software. The page is as fellows:
Related AT command
command name Instr
AT+sock Setting the work mode/target IP/ target port
Form 4.2-1 socket AT command
1) In TCP Server Mode, T2 monitors local port, it will response and establish a connection when there is a request. When
the T2 receive the data, it will send it to all the client connected to T2, meanwhile, this mode can monitor the connect
timely with keepalive function.
2) Usually it is used in the LAN communicating with TCP client. Adopt the case that more than one PC or phone asking data
without server. Same as the TCP client ,there are different between connect and disconnect.
3) Support synchronizing baud rate.
TCP Client number is from 1 to 16, default value 4. the port is fixed., can not be set to 0.
1) UDP server is a IP address do not verify the resource in the normal UDP. After receive every UDP package, change the
target IP into data resource IP and port. When sending data, sending to the least IP and port.
2) Usually this mode, several net device communicate with module and do not want to use TCP for high frequency.
In this mode , users’ terminal device can send required data to assigned HTTPD server via USR-TCP232-T2, and when
TCP232-T2 receives the data from HTTP server, analyzes the data and sends the result back to the serial port.
No need for paying attention to the process of data conversion between the serial data and net data package. Simple
parameter setting can realize the requirement serial device sent to HTTP server.
TCP UDP
Stable; Transmission interval is accurate; No
Advantages Not easy to lose data package;
connection mechanism;
Reliable connection mechanism;
Easy and flexible;
Disadvantage Easy to block up Information; Under bad network condition, it is
Because of check and resend high risky to losing data package
mechanism, interval isn’t accurate
4.4. VCOM
USR-VCOM Download: http://www.usriot.com/usr-vcom-setup-software-v3-7-1-520/
USR-VCOM Manual: http://www.usriot.com/usr-vcom-setup-software-user-manual-v3-5-2/
If user’s upper computer and device are all connect by serial port, user can create a COM which has TCP/ IP to realize
remote control by USR-VCOM software.
1) Turn off firewall and anti-virus software.
2) Install USR-VCOM.
I advise user to choose “Search”or “Smart vcom” to create virtual port. Please refer to 4.4.3
2) Automatically Create
Serial port basic parameters including: baud rate; data bits; stop bits; parity.
1. Baud rate: communicating speed of serial port, can be set from 600~460.8Kbps, support random baud rate.
2. Data bits:the range of it from 5 to 8.
3. Stop bits:can set from 1 to 2.
4. Parity: support none, odd, even, mark and space
Since the data on the network is transmitted in the unit of data frames, it is necessary to send the frame data via serial
port to the network, so as to transmit data more efficiently and quickly.T2 packages serial port data according to fixed
packaging length and packaging time during data transmission.The default T2 packaging time is 4 bytes of packaging time
and 400 bytes of packaging length.
The frame mechanism of serial port is based on the packaging time and the packaging length.
Serial port packaging time: the default is 4 bytes of send time.
Serial port package length: default package length is 400 bytes
4.5.3. RFC2217
This function is used to change USR-TCP232-T2 serial port parameter through network. E.g: change baud rate from
115200bps to 9600bps. It can be set by software or webpage.
By default ,it is in open state.
When using VCOM software, this function also works, the baud rate of software in PC will match Autonomic with the
baud rate of USR-TCP232-T2, don’t need to focus on serial port baud rate.
After restart, it is default parameter.
In the transparent transport mode, user can choose T2 to send heartbeat package. Heartbeat package can be sent to
net server, also can send to serial port, but can not send in the same time.
Sending to the net aimed at connecting with server, effect only in TCP client and UDP client.
In the application of the server sending fixed query command to device, to reduce the communication flow. The user
can choose using the serial port to send the heartbeat package instead of the heartbeat from server.
The content of heartbeat package can be defined. The longest content is 40 bite. Time set from 1s to 255s.
It can ensure connection is reliable, put an end to connect feign death.
In the transparent transport mode, user can choose T2 to send registration package. Registration package is used to
identify data sources or do as the code to get the server authorization.
Registration package can be sent when the T2 built connection with server, also can installed in the head of the data
package, as a data package. Registration package data can be MAC address or customize registration package data, where
the custom registry setting content is up to 40 bytes.
The connection setting and sending registration package is mainly used to connect the server that needs to be
registered. By default, this function is not checked.
Data carries the registration package: sending data in the front of the data access to the registration package,mainly
for protocol transmission application.
4.6.3. USR-cloud
T2 support customize webpage. The user can upgrade their webpage into T2 via customize webpage. To be more
convenient for user, we have prepared upgrade webpage package in our website:
https://www.usriot.com/support/downloads/customized-webpage-usr-tcp232-t2-s2-customized-webpage-v4017.html
including webpage code, webpage tools can be download.
Upgrade webpage need to note that, destination IP set to be the IP address of T2, the final name of file is “fs”,product
choose the”M0”, then click the upgrade.
4.6.5. Link
Link pin is the status indicator pin for T2 to built communication. Link pin can be used as indication pin for TCP
connection status.
When connected, it output low level; When unconnected, high level.
When T2 is under TCP model, Link pin will pull down. otherwise, it stays in high level.
When T2 is under DUP model, Link pin will always pull down. By default, it is not checked.
4.6.6. Reset
Reset used when the T2 fly or crash and can not built the normal connection,so can not work. Reset to initialize the
module to resume normal operation.
When T2 works as TCP Client, T2 connects to TCP Server actively. When start Reset function, T2 try to connect to TCP
Server for 30 times. If failed, T2 will restart automatically. By default, it won’t be chose.
4.6.7. Index
Index is to resolve the problem that in TCP server mode, T2 can not divide the data sources or send data to special
client when user have more than 2 client to connect the T2.
At most there can be 16 links when the T2 in the TCP server mode. The max number can set from 1to 16 as you want.
Here we take the default number is 16 as example. Server send data to 16 clients, or the server receive the data from 16
clients, open the Index, mark to divide the different clients and user can recognize the data sources according to the mark,
meanwhile send different data to special clients.
Index function can be set by software or web-page.
Then the USR-TCP232-T2 work in the TCP server mode, the max number of client to connect is 16, default is 4,the max
number can be configuring as you want, which is be convenient for use. When the the number connecting clients more
than 4, we should control the total data flow in 2.5KB/s if we need to send and receive meanwhile(not more than 200
bite/s).
If the number is 16 now, default use the new link instead of the older one, also you can set to use the older one. The
webpage are as fellow.
4.6.9. State
In the webpage of the USR-TCP232-T2, there is the state config page, which can show the current IP and the each
connection sends data and the number of bytes of connection data, along with the total number of bytes sent and
received by the T2 server on the page.
Now,under the TCP client mode, T2 can statistic the former 5 IP of devices and the number of the sent and received
data. Refresh every ten seconds automatically. Under the TCP server mode, the T2 only static the number of the sent and
received data, no connected IP.
The aim to use this function is to save the resource of the server,usually used in the points to one point. Using the
short connection can sure the current connection is the useful one, no extra control tools to screening.
TCP short connection can used in the TCP client, open it and send message. The connection will be broken
automatically.
This function default to be off, the interval of disconnect can be configured after this function is open, the range from
2 to 255s, default is 3s, the diagram is as fellow:
If the TCP have not built, the data that serial received will be placed in the cache, and the T2 serial port can receive
2Kbyte, after the TCP built, you can select is clear the cached data.
The default is not. Under the Httpd client mode or the TCP client mode, open the short connection and this function
has no power.
Restore out time is to make sure the long and stable work of T2, when the net port or network can not receive data
for long time, T2 will restore out the setting time to avoid abnormal conditions affect the connection. Time for restore can
set in the webpage. The normal work time of this function set 60~65535s, default is 3600s. if setting time less than 60s,
default to be 0 and turn off this function. The setting is as fellow:
5. Parameter setting
This character mainly to introduce how to setting the T2 parameters. Achieve their own personalized application
through parameter settings
Including setting software setting parameter, webpage setting parameter and serial setting parameter.
User setting steps:
Modify the user name and password→ setting the access way to the IP address→ serial parameter→ the related
parameter for work method.
To ensure the normal use of software, the following steps are necessary
1. When using setting software to setting parameter, T2 and the PC of the setting software are in a LAN.
2. Close the antivirus software and firewall software.
3. Close the irrelevant network card.
Open the software and click search, searching all the T2 in the LAN. The information you need to search including
current IP, device name, MAC address and the vision of T2.
(download: https://www.usriot.com/support/downloads/usr-m0-setup-software-v224287.html).
1. Click the searching content, check the password of the T2 at first, if the password is right, the information for T2
will be shown. If the password is wrong, the software will pop-up a window for username and password. Fill in the right
one and click enter. The default name and password are admin), so if all thing are default, the setting software will not
pop-out the widow of username and password.
3. Serial parameter
Serial baud rate: the baud rate for serial port communication, both standard and customize baud rate are ok.
Parity/data/stop: serial port parameters
Work mode: TCP Server /TCP Client/Httpd Client/UDP Client/UDP Server
Remote IP: when T2 works in TCP client, UDP client and HTTPD client mode as a client, the IP or domain name of the
server that it connected.
Similar RFC2217: ussed if need to change the serial port in transport. Use with V-COM or you can reference the
software manual.
4. Check data
6. Firmware upgrade
If the module firmware need to upgrade to the high vision,user can consult with sales to get the upgraded firmware
and click the device, upgrade the vision. When you upgrade it,connect directly the device and PC and notice that PC
upgrading module is forbidden.
Select the device and right click, then upgrade the firmware.
Achieve it: searching→ setting→ save→ restore using protocol, which is convenient for user to make their setting
software, details you can find the “USR-TCP232-T2 software manual”.
Open the browser and enter the IP of T2, default is 192.168.0.7 or you can click right on the T2 and open web,
filled the user name: admin and password: admin, then login and you can enter the login page.
Click the English or Chinese on the right upper to switch the language.
5.2.2. Local IP
Modify the parameters and save, then modify the parameter in next page. If the parameter need not to modify, click
the restore and work.
5.2.6. Reboot
5.3. AT comment
Instr
AT command test tools. UART interface command to use secureCRT software tool or USR pro APP. Below are using the
secureCRT with UART to perform.
From transparent transport to AT command need two step as below:
Fill “+++”in the UART. After the module receive the “+++”,it will send a “a” to confirm;
Fill the confirming “a” in the UART, after the module receive and send “+ok”, enter the AT command mode.
Time requirement:
T1>the interval of serial port package
T2<300ms
T3<300ms
T5<3s
The order change into temporary command mode from transparent transport mode:
1. Serial mode device send “+++”to module continuously. The module receive and send “a” back. Before
sending“+++”is the packaging time and can not send any data.
2. After receive “a” feedback a “a”in 3s.
3. After the module receive “a, send “ok”to the device, and enter “AT”command
4. After the device receive “+ok” and know the module enter the AT command mode, then send AT command.
The order change into transparent transport mode from AT command mode:
Jinan USR IOT Technology Limited 52 www.usriot.com
USR-TCP232-T2 user manual www.usriot.com
1. Serial device send “AT+ENTM”to module.
2. After the module receive the command, feedback “+ok”, then back to the previous working mode.
5.3.3. AT command
NO command Instr
1 E Enable/disable the echo function
2 Z Restore module
3 VER Query the vision
4 ENTM Exit AT command mode
5 RELD Reset default settings
6 MAC Query module MAC address
7 USERMAC Setting customize MAC
8 WEBU Setting/ query username and password
9 WANN Setting/ query WAN port parameters
10 DNS Setting/ query DNS server address
11 WEBPORT Setting/ query webpage port
12 UART Setting/ query serial parameters
13 SOCK Setting/ query SOCK parameters
14 TCPSE Setting/ query whether kick off order connection
15 SOCKLK Query TCP connect status
16 SOCKPORT Setting/ query local port number
17 RECEN Setting/ query RFC2217 enable
18 PDTIME Query the product time
Registration package function
19 REGEN Setting/ query registration package mechanism
20 REGTCP Setting/ query registration package perform mechanism
21 REGCLOUD Setting/ query USR-cloud username and password
22 REGUSR Setting/ query the content of registration package that
customized
Jinan USR IOT Technology Limited 53 www.usriot.com
USR-TCP232-T2 user manual www.usriot.com
Httpd client function
23 HTPTP Setting/ query in httpd client mode, the asking way of the
http
24 HTPURL Setting/ query the URL in httpd client mode
25 HTPHEAD Setting/ query the package head in httpd client
26 HTPCHD Setting/ query HTP remove the package head
Heartbeat package
27 HEARTEN Setting/ query heartbeat package enable
28 HEARTTP Setting/ query method of the heartbeat package send
29 HEARTTM Setting/ query the heartbeat package time
30 HEARTDT Setting/ query customize heartbeat package
Expand function command
31 SCSLINK Setting/ query the indicating function of the status of socket
connection
32 CLIENTRST Setting/ query the TCP client mode reset function
enable/disable
33 INDEXEN Setting/ query index function
34 SOCKSL Setting/ query short connection function
35 SHORTO Setting/ query short connection time
36 UARTCLBUF Setting/ query clear serial port cache before module build
connection function enable/disable
37 RSTIM Setting/ query timeout reset time
38 MAXSK Setting/ query maximum client connections in TCP server
mode
39 MID Setting/ query module name
40 H Query help message
(V4017 supporting command)
41 AT+CFGTF Save the current parameters as the default parameters
42 AT+PING Ping automatically
Form5.3.3-1 AT Command
5.3.4. AT command
5.3.4.1. AT+E
Format: query:
A+E<CR>
<CR><LF>+OK=< on/off ><CR><LF>
Setting:
A+E=< on/off ><CR>
<CR><LF>+OK<CR><LF>
Jinan USR IOT Technology Limited 54 www.usriot.com
USR-TCP232-T2 user manual www.usriot.com
Parameters: ON: enable the echo, echo the command entered by the AT command.
OFF: under AT command mode, the entered command do not echo.
E.g.: AT+E=on
5.3.4.2. AT+Z
5.3.4.3. AT+VER
5.3.4.4. AT+ENTM
Function: exit the AT command mode and enter the transparent transmission:
Format: setting:
AT+ENTM<CR>
<CR><LF>+OK<CR><LF>
Parameters: none
<note>: after perform this command correctly, module change into command mode from transparent transmission
mode.
5.3.4.5. AT+RELD
5.3.4.6. AT+MAC
5.3.4.7. AT+USERMAC
5.3.4.8. AT+WEBU
5.3.4.9. AT+WANN
5.3.4.10. AT+DNS
5.3.4.11. AT+WEBPORT
5.3.4.12. AT+UART
5.3.4.13. AT+SOCK
5.3.4.14. AT+TCPSE
Function: module is TCP Server, the processing mechanism after the connection reaches the maximum number of
connections.
Format: query:
AT+TCPSE<CR>
<CR><LF>+OK=< status ><CR><LF>
setting:
AT+TCPSE=< status ><CR>
<CR><LF>+OK<CR><LF>
Parameters:
Status: setting status keep/kick
keep: after reach the maximum number of connection, do not receive new one.
kick: after reach the maximum number of connection, delete the order one and
connect the new one.
E.g.: AT+TCPSE=keep
5.3.4.15. AT+SOCKLK
5.3.4.16. AT+SOCKPORT
5.3.4.17. AT+RFCEN
5.3.4.18. AT+PDTIME
5.3.4.19. AT+REGEN
5.3.4.20. AT+REGTCP
Function: setting query tcp client mode registration package perform mechanism
Format: query:
AT+REGTCP<CR>
<CR><LF>+OK=< status ><CR><LF>
setting:
AT+REGTCP =< status ><CR>
<CR><LF>+OK<CR><LF>
Parameters:
Status:
first: send a registration package when connected the server at first time
every: add a registration package in front of the every data package sent to server.
all: send registration package when first connected to the server and add registration
package in front of the data package.
E.g.: AT+REGTCP=first
5.3.4.21. AT+REGCLOUD
5.3.4.22. AT+REGUSR
5.3.4.23. AT+HTPTP
Function: setting /query the asking way under HTTPD Client mode.
Format: query:
AT+HTPTP<CR>
<CR><LF>+OK=< status ><CR><LF>
setting:
AT+HTPTP =< status ><CR>
<CR><LF>+OK<CR><LF>
Parameters:
Status:
GET: is the http asking way
POST: is the http asking way
E.g.: AT+HTPTP=GET
5.3.4.24. AT+HTPURL
5.3.4.25. AT+HTPHEAD
5.3.4.26. AT+HTPCHD
Function: setting /query filter the package head of the return information of Http
Format: query:
AT+ HTPCHD <CR>
<CR><LF>+OK=< sta ><CR><LF>
setting:
AT+ HTPCHD =< sta ><CR>
<CR><LF>+OK<CR><LF>
Parameters: Sta:
ON: enable
OFF: disable
E.g.: AT+HTPCHD=ON
5.3.4.27. AT+HEARTEN
5.3.4.28. AT+HEARTTP
5.3.4.29. AT+HEARTTM
5.3.4.30. AT+HEARTDT
Function: setting /query Socket connected status instructions function (connection status instructions pin change or
not according to the connection status)
Format: query:
AT+ SCSLINK <CR>
<CR><LF>+OK=< sta ><CR><LF>
setting:
AT+ SCSLINK =< sta ><CR>
<CR><LF>+OK<CR><LF>
Parameters: sta: status
ON: enable link function
OFF: disable link function
E.g.: AT+ SCSLINK=ON
Function: setting /query TCP Client mode filed to connect several time and reset ( repeat 30 times connection failed,
module restart )
Format: query:
Jinan USR IOT Technology Limited 63 www.usriot.com
USR-TCP232-T2 user manual www.usriot.com
AT+ CLIENTRST <CR>
<CR><LF>+OK=< sta ><CR><LF>
setting:
AT+ CLIENTRST =< sta ><CR>
<CR><LF>+OK<CR><LF>
Parameters: sta: status
ON: enable TCP Client reset function
OFF: disable TCP Client reset function
E.g.: AT+CLIENTRST =ON
Function: setting /query if the module clear the serial port cache before connected
Format: query:
AT+ UARTCLBUF <CR>
<CR><LF>+OK=< sta ><CR><LF>
setting:
AT+ UARTCLBUF =< sta ><CR>
<CR><LF>+OK<CR><LF>
Parameters: sta: status
ON: clear the serial port cache before connected
OFF: do not clear the serial port cache before connected
E.g.: AT+UARTCLBUF =ON
Function: setting /query the maximum number of the client that TCP Server connected Format: query:
AT+ MAXSK <CR>
<CR><LF>+OK=< num ><CR><LF>
setting:
AT+ MAXSK =< num ><CR>
<CR><LF>+OK<CR><LF>
Parameters: num: the maximum number of the client that TCP Server connected, range from 1 to 16
E.g.: AT+MAXSK =4
5.3.4.40. AT+ H
Function: help
Format: query:
AT+ H <CR>
<CR><LF>+OK=< sta ><CR><LF>
Parameters: sta: help information
5.3.4.41. AT+CFGTF
5.3.4.42. AT+PING
6.Contact us
Company: Jinan USR IOT Technology Co., Ltd
Web: www.usriot.com
Support: https://h.usriot.com
Email: [email protected]
7.Disclaimer
The document provides information about USR-TCP232-T2 module, it doesn’t grant any license to the intellectual
property rights. Except the responsibility declared in the product sale clause, USR does not assure any other responsibilities.
In addition, USR does not make any warranties for the sale and use of this product, including the suitability of products for
a particular purpose, merchant ability or fitness for any patent, copyright or other intellectual property infringement. USR
may make changes to specifications and products description without notice.