Technical Brochure: High Pressure Multi-Stage Pumps

Download as pdf or txt
Download as pdf or txt
You are on page 1of 32

TECHNICAL BROCHURE

BMPVN R1

MPVN
HIGH PRESSURE MULTI-STAGE PUMPS
Goulds Water Technology
Commercial Water

A FULL RANGE OF PRODUCT FEATURES

Performance Range:
Capacities up to 1500 GPM (340 m3/h)
Head up to 1640 feet (500 m)
Maximum speed up to 3600 RPM

Sizes:
From 11⁄2" to 5" discharge.

Maximum Temperature:
280° F (140° C)

Maximum Casing Pressure:


800 psig (55 bar)

Handled Liquids:
Pure as well as slightly contaminated media such as:
Cold and Hot Water
Condensate
Oil Suspensions
Acids as well as their watery solutions

Applications:
Water Supply
Booster Systems
Irrigation
Fire Fighting
Snow Making
Cooling Circuits
Boiler Feed
Condensate
District Heating
Reverse Osmosis and Ultra Filtration
The MPVN is manufactured for Goulds Water
Spray Water Systems
Technology by Austria Gmbh, formally called Vogel
Cleaning Systems
Pumpen, at their plant near Vienna, Austria.
Modular System:
VOGEL Vertical Multistage pumps utilize a modular design
concept which maximizes component interchangeability. As
such, multiple design configurations can be engineered to
meet customer requirements without compromise to repair
part inventories. The entire performance range is covered by
4 mechanical sizes that hold 8 different hydraulics.

Hydraulics:
Closed radial type impellers designed for casing wear rings
on both sides. Axial thrust is minimized by balance holes for
minimum bearing loads and maximum bearing lifetime.
Diffusers separated from stage casings, easily exchangeable.
Balanced radial forces, minimum shaft deflection, minimum
vibrations.

HEAVY DUTY DESIGN FOR LONG-TERM


OPERATION IN INDUSTRIAL APPLICATIONS.

PAGE 2
Goulds Water Technology
Commercial Water

MPVN LIQUID END NUMBERING SYSTEM

MPV 2 03 B 3 A D 1 A

Flange Orientation:
A = Left Suction, Left Discharge (code OO)
B = Left Suction, Rear Discharge (code OR)
C = Left Suction, Front Discharge (code OL)
D = Left Suction, Right Discharge (code OG)

Seal Materials: For Optional Mechanical Seal modify catalog order no. with Seal Code listed below.
Seal Code Rotary Stationary Elastomers
1 EPR
Carbide Sil-Carbide
2 Viton

Motor Frames:
D = 254TD/256TD J = 364TSD/365TSD O = 444TD/445TD
E = 284TSD/286TSD K = 364TD/365TD P = 447TSD/449TSD
F = 284TD/286TD L = 404TSD/405TSD R = 447TD/449TD
G = 324TSD/326TSD M = 404TD/405TD S = 5009SD
H = 324TD/326TD N = 444TSD/445TSD

Pump Material:
A = All Iron C = Stainless Fitted
B = Bronze Fitted D = All Stainless

Seal Type:
2 = SA – Unbalanced 3 = SB – Balanced

ANSI Discharge Flange Class:


A = 150
B = 300
C = 600

Number of Stages

Pump Size:
1 = 40.1 4 = 65.1 7 = 100.2
2 = 40.2 5 = 65.2 8 = 125.1
3 = 40.3 6 = 100.1 9 = 125.2

Pump Model

Complete Pump Consists of: Liquid End, Coupling and Motor.

PAGE 3
Goulds Water Technology
Commercial Water

MPVN SECTIONAL ASSEMBLY

Type MPVN:
• Vertical configuration with separate thrust bearing, grease
lubrication with grease nipples.
• Standard motor according to NEMA MG1-4.07, D flange
mounting.
• Flexible coupling between pump and motor.
• Product lubricated sleeve bearing in suction casing.
• Maintenance friendly design. Shaft sealing maintainable
without pump disassembly.

Shaft Seal Options:

Mechanical Seal:
Seal chamber dimensions-comply with ISO 3096. Mechanical seals of all brands that comply with this standard and EN 12756,
version “K” can be used without modification of the standard parts.
The taper bore type seal chamber is self venting and guarantees optimum lubrication and cooling of the seal faces.

Single mechanical seal, design SA Single mechanical seal, design SB


unbalanced up to a maximum of 250 PSI (16 bar) balanced up to a maximum of 800 PSI (55 bar)

PAGE 4
Goulds Water Technology
Commercial Water

MPVN PARTS INDEX

Table of Materials
Material Code
111 211 311 532
Pos. Index of Part
All
Cast Iron Bronze Fitted Stainless Fitted
Stainless
1 Impeller 0.6025 2.1050.01 1.4408 1.4408
2, 2/E Diffuser 0.6025 0.6025 0.6025 1.4408
3 Suction casing 0.6025 0.6025 0.6025 1.4408
0.6025 0.6025 0.6025
4 Discharge casing 1.4408
(Class 600 –0.7040) (Class 600 –0.7040) (Class 600 –0.7040)
9 Wear ring 1) 1) 1) 1.4408
8, 12 Bearing cover 0.6025 0.6025 0.6025 0.6025
18 Seal cover 0.6025 0.6025 0.6025 1.4408
PEEK /
21 Bearing bush G-CuSn16 G-CuSn16 G-CuSn16
1.4462
23, 2444 Shaft and shaft sleeves 1.4021 1.4021 1.4021 1.4462
Intermediate bearing housing,
60 0.6025 0.6025 0.6025 1.4408
stage casing
1) Upon request of 1.4410 possilble
Elastomers (O-Ring) of EPDM for hot water up to 284°F (140°C) (Pay attention to operation limits and chemical resistance),
optional Viton elastomers available.

PAGE 5
Goulds Water Technology
Commercial Water

MPVN MATERIAL SPECIFICATION DIN-ASTM


Casted Material Standards DIN Designation DIN ASTM UNS
A48 Class 30 (general castings)
Cast Iron EN GJL-250 (GG 25) 0.6025 F12401
A278 Class 30 (press. castings)
EN-GJS-400-18-LT 0.7043 A395 Grade 60-40-18 F32800
Ductile Iron
EN-GJS-400-15 (GGG 40) 0.7040 A536 Grade 60-40-10➁ –
Carbon Steel GP 240 GH (GS-C25) 1.0619 A216 – WCB J03002
1.4408 1.4408 A351 / A743 / A744 CF-8M➂ J92900
Stainless Steel
1.4410 1.4410 A789 / A790 Typ 2507➀ S32750
Duplex SS 1.4517 1.4517 A351 CD4-MCu
Bronze G – CuSn 10 / CC480K 2.1050.01 B427➃ C90700
Wrought Material Standards
Stainless Steel 1.4021 1.4021 A276 Typ 420 S42000
Duplex SS 1.4462 1.4462 A276 Typ 2205 S31803
Fastener Materials (Bolts)
Carbon Steel DIN 267 Class 8.8 1.7225 A193 B7 J41400
Stainless Steel A2 A2 A193 B8 S30400
Stainless Steel A4 A2 A193 Grade B8M S31600
➀ only used for casing wear rings ➂ A351/A743 for general applications A744 for several services
➁ less elongation ➃ also available B148/B584

COMPARISON OF VARIOUS STANDARDS


EN (DIN) ISO BSI (UK) AISI ASTM UNS
0,6025 EN-GJL-250 (GG 25) 185/Gr. 250 1452 Gr. 220 A 278 Class 30
0.7040 EN-GJS-400-15 (GGG 40) 1083/400-12 A 536 Gr. 60-40-18
2.1050.01 G-CuSn10 B584 C 90700
1.0421 X20Cr13 683-13-4 970 420 S 37 420 A 276 Type 420
A (351) 744 Gr.
1.4408 G-X6CrNiMo 18-10 3100-316 C 16 CF8M
CF8M
1.4410 X2CrNiMoN25-7-4 A182/A479/2276 S32750
S31803
1.4462 X2CrNiMoN22-5-3 1503 318 S13 A240
S32205

MECHANICAL SEAL MATERIALS


DIN Code Mechanical Seal Stationary Ring Elastics Metal Parts
BQ 1 EGG EPDM
Carbon➀
BQ 1 VGG SIC➁ 316TC
Viton
Q1 Q1 VGG SIC➁
➀ Carbon resin impregnated
➁ Pure silicon carbide (without free silicone)

PAGE 6
Goulds Water Technology
Commercial Water

SHAFT SEAL: MECHANICAL SEAL CODE . . .SA (UNBALANCED)


Sizes: MPVN40.2 through MPVN125.2

Part
Description
Number
1 Impeller
2 Diffuser
2E Diffuser, last stage
3 Suction casing
4 Discharge casing
8 Bearing pedestal
12 Bearing cover
18 Seal cover
21 Bearing bushing
23 Bearing sleeve
24 Shaft
25 Tie bolt
28 Impeller nut
29 Washer
44U Shaft wearing sleeve
50 Bearing nut
60 Stage casing
69 Gland
72 Spacer sleeve
73M Thrower
73P Thrower
95 Shaft guard
D Drain plug
DR Throttling element
G Grease nipple
GLRD1 Mechanical seal
K Radial ball bearing
M1 Nut
M5 Nut
OR1 O-ring
OR2 O-ring
OR3 O-ring
OR4 O-ring
PM1 Pressure gauge
PM2 Pressure gauge
PF1 Key
PF2 Key
PF3 Key
PF4 Key
S4 Pin
S5 Stud
V1 Plug, threaded
V3 Plug, threaded
W1 Washer

PAGE 7
Goulds Water Technology
Commercial Water

SHAFT SEAL: MECHANICAL SEAL CODE . . .SB, SD (BALANCED)

Sizes: MPVN40.2 through MPVN125.2

Part
Description
Number
1 Impeller
2 Diffuser
2E Diffuser, last stage
3 Suction casing
4 Discharge casing
8 Bearing pedestal
12 Bearing cover
18 Seal cover
21 Bearing bushing
23 Bearing sleeve
24 Shaft
25 Tie bolt
28 Impeller nut
29 Washer
44B Shaft wearing sleeve
50 Bearing nut
60 Stage casing
69 Gland
72 Spacer sleeve
73M Thrower
73P Thrower
95 Shaft guard
D Drain plug
DR Throttling element
G Grease nipple
GLRD1 Mechanical seal
K Radial ball bearing
M1 Nut
M5 Nut
OR1 O-ring
OR2 O-ring
OR3 O-ring
OR4 O-ring
PM1 Pressure gauge
PM2 Pressure gauge
PF1 Key
PF2 Key
PF3 Key
PF4 Key
S4 Pin
S5 Stud
S7 Pin
V1 Plug, threaded
V3 Plug, threaded
W1 Washer

PAGE 8
Goulds Water Technology
Commercial Water

PRESSURE AND TEMPERATURE LIMITS

Maximum Allowed Operating Pressure (Casing and Flanges): Material Code 111 (Cast Iron), 211 (Bronze Fitted), 311 (SS Fitted)
60

800

700
50 ASME Class 600 Flange
Discharge Casing - Ductile Iron

600
40

Flanges ASME Class 300 – MPVN.# - Ductile Iron


500
Bar
PSI

30
400
Flanges ASME Class 300
Size: MPVN40.#, MPVN65.#, MPVN125.#
300 Discharge Casing - Cast Iron
20

200

10 Flanges ASME Class 150


100 Discharge Casing - Cast Iron

0 0
–20 0 20 40 60 80 100 120 140 T (ºC)

0 50 100 150 200 250 300 (ºF)

Maximum Allowed Operating Pressure (Casing and Flanges): Material Code 532 (All Stainless)
60

800
Flanges ASME Class 600
50
700

600
40

500
Flanges ASME Class 300
Bar
PSI

30
400

300
20

200 Flanges ASME Class 150


10
100

0 0
–20 0 20 40 60 80 100 120 140 T (ºC)

0 50 100 150 200 250 300 (ºF)

Maximum Allowed Operating Pressure = incoming pressure at suction flange and pump head at 0 flow.
PAGE 9
Goulds Water Technology
Commercial Water

SELECTION CHARTS FOR SHAFT SEALING WITH MECHANICAL SEAL


Sealing Code of Mechanical Seal:

Discharge General:
Code
Side Area IV: Mechanical seal acc. DIN 24960, U-shape with L1k, Material: carbon – SiC - EP
IV SA Area V: Mechanical seal acc. DIN 24960, B-shape with L1K, Material: carbon – SiC - EP
Area VI: Mechanical seal acc. DIN 24960, B-shape with L1k, Material: carbon – tungstencarbide - EP
V SB
VI SD* Selection charts are only valid for clean water resp. demineralized boiler feed water. For SiO2 (silicic acid)
* upon request contents > 4 mg/l resp. SiO2 containing water treatment liquids, please ask manufacturer.
Clean liquids, solids < 10 mg/l
Minimum pressure at suction flange at temperatures > 176°F (80°C) needs to be available.

50
2’

3’
40
VI

30 V
Bar

2
20
3

1
10
2
IV 3
0
0 20 40 60 80 100 120 140 min. PGLRD
T (ºC)

PAGE 10
Goulds Water Technology
Commercial Water

MPVN PERFORMANCE RANGE – 60 HZ


3550 RPM
520 1600
480 1500

440 1400

1300
400
1200 Size 40.2 100.1
360
1100
65.1 125.1
320
Total Head H (ft)

1000
40.3

125.2
280 900
H (m)

800 65.2
240
700
200 600

160 500

400
100.2
120
300
80
200
40 100
0 0
0 15 20 30 40 50 100 150 200 300 400 500 1000 US GPM
Capacity Q
m3/h

3 4 5 6 7 8 9 10 15 20 30 40 50 100 150 200 300 400 500

1750 RPM
500

400 1500

300 1000

200

125.1
Total Head H (ft)

500
125.2
100.1
40.2

65.1
40.3

65.2

400
H (m)

100
300
100.2

200
50

40

30 100

20 0
0 10 15 20 30 40 50 100 200 500 1000 2000 3000 US GPM

m3/h
2 3 4 5 10 20 30 40 50 100 200 300 500 1000 1500

PAGE 11
Goulds Water Technology
Commercial Water

MPVN SELECTION CHARTS


Single Stage
0 1 2 3 4 5 6 7 8 9 10 11 12 Q (l/s) 0 1 2 3 4 5 6 7 8 9 10 11 12 Q (l/s)
65 850 260
200 MPVN40.2/1 60 800
MPVN40.2/..
Dia. 170 mm
3550 RPM 750
/4 3550 RPM 240
180 55 220
700

Total Head H (ft)


Total Head H (ft)

160 50 650 200


Dia. 150 mm
600
45 /3 180
140 550

H (m)

H (m)
40 160
500
120 Dia. 130 mm 140
35 450
0
100 400 /2 120
30
350
100
80 1 25 300
80
250

P (KW)
20
/1
2 200 60
60 15
n cy

P (KW)
150
icie 40
35
Eff
Efficiency (%)

50 0 100
1 HP
50 /4 30
HP
40
40 8 Impeller Dia. 170 mm
2 HP 25
0 10
30 7 /3 30
9 20
20 8 6
HP /2 20 15
10 1 7
5
10
6 NPSHr /1
NPSHr 4 10
(m) (ft) 2 5 (m) (ft) 5
15 15
4
0 4 3 4 0 0
10 NPSH 10 NPSH
2
3 2 2
5 5
MP42/301-0 MP42/302-0
0 0
0 20 40 60 80 100 120 140 160 180 200 US GPM 0 20 40 60 80 100 120 140 160 180 200 US GPM
Capacity Q Capacity Q

0 5 10 15 20 25 30 35 40 45 m3/h 0 5 10 15 20 25 30 35 40 45 m3/h

0 1 2 3 4 5 6 7 8 9 10 11 12 Q (l/s)
480

1500
/8 MPVN40.2/.. 460
3550 RPM
440
1400
420
/7
1300 400
Total Head H (ft)

380
1200
H (m)

360
/6
1100 340
320
1000
300
/5
900 280
260
800 240

220
700
200
P (KW)

600 180
Impeller Dia. 170 mm
160
500
HP

/8 80 60
HP /7 50
/6 60
NPSHr /5 40
(m) (ft) 40 30
15
4
10 20 20
NPSH
2 10 10
5
MP42/303-0
0
0 20 40 60 80 100 120 140 160 180 200 US GPM
Capacity Q

0 5 10 15 20 25 30 35 40 45 m3/h

PAGE 12
Goulds Water Technology
Commercial Water

MPVN SELECTION CHARTS


Single Stage
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Q (l/s) 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Q (l/s)
200 65 240
750 /4
Dia. 170 mm
MPVN40.3/1 60 MPVN40.3/.. 220
180 3550 RPM 700 3550 RPM
55
650 200
Total Head H (ft)

Total Head H (ft)


160
50 600
/3 180
140 Dia. 150 mm 550
45
160
500

H (m)
H (m)
120 40
450 140
Dia. 130 mm 35
100 400 /2 120
0 30
80 350
100
25 300
1 80
20 250
Efficiency (%)

70 2
200 /1 60

P (KW)
60
n cy 150
40
icie
Eff
50 100

HP
P (KW)
0 /4 40
40 1 50
2 HP Impeller Dia. 170 HP
/3 30
14
0 10 30
NPSHr HP 12 NPSHr /2 20
(m) (ft) 8 (m) (ft)
30 10 30
0 /1 10
8 1 8 6 8 10
25 25
2 6 0 0
6 20 4 6 20
NPSH
15 NPSH 4 15
4 2 4
2
10 10
2 0 0 2
5 5
MP43/301-0 MP43/302-0
0 0
0 20 40 60 80 100 120 140 160 180 200 220 240 260 US GPM 0 20 40 60 80 100 120 140 160 180 200 220 240 260 US GPM
Capacity Q Capacity Q
0 5 10 15 20 25 30 35 40 45 50 55 60 m3/h 0 5 10 15 20 25 30 35 40 45 50 55 60 m3/h

0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Q (l/s)
480
/8
1500 MPVN40.3/.. 460
3550 RPM 440
1400
420
Total Head H (ft)

/7
1300 400
380
1200
/6 360
H (m)

1100 340
320
1000 300
/5
900 280
260
800
240
700 220
Impeller Dia. 170
200
600
180
P (KW)

500 160
HP

400 NPSHr 110


/8 80
(m) (ft)
35 /7 90 70
HP
30 /6 60
8 70 50
25 /5
6 20 40
50
15 30
4 NPSH
10
30 20
2
5
MP43/303-0
0
0 20 40 60 80 100 120 140 160 180 200 220 240 260 US GPM
Capacity Q
0 5 10 15 20 25 30 35 40 45 50 55 60 m3/h

PAGE 13
Goulds Water Technology
Commercial Water

SELECTION CHARTS: MPVN 40.2 n = 1750 RPM


Single Stage
0 1 2 3 4 5 6 Q (l/s) 0 1 2 3 4 5 6 Q (l/s)
15 90

45
Dia. 170 mm
MPVN40.2/1 14
280
/6 MPVN40.2/.. 85

1750 RPM 13
260 1750 RPM 80
75
40 12 240
/5 70
Total Head H (ft)

Total Head H (ft)


Dia. 150 mm 220
11 65
35
10 200 60

H (m)

H (m)H (m)
30 /4
9 180 55
Dia. 130 mm
50
8 160
25 0 45
7 140 /3
40
20 6 120 35
1
5 100 30
15 /2
2 4 80 25
20
60
Efficiency (%)

P (KW)
/1 15
60
ncy 40
icie 10
50 Eff
P (KW)

20 5 6
0 /6
40 1 Impeller Dia. 170 mm

HP
5
/5 7
HP

2 HP
1.0 4
0 1.3 /4 5
NPSHr 1.1 0.8 NPSHr /3 3
(m) (ft) HP (m) (ft) 3 2
3 1 0.9
0.6 3 /2
8 0.7 8 /1 1
2 2 2
1
0.5 0.4
0 0 0
4 NPSH 0.3 4
1 0.2 1 NPSH
MP42/401-0 MP42/402-0
0 0
0 10 20 30 40 50 60 70 80 90 US GPM 0 10 20 30 40 50 60 70 80 90 US GPM
Capacity Q Capacity Q
0 2 4 6 8 10 12 14 16 18 20 22 m3/h 0 2 4 6 8 10 12 14 16 18 20 22 m3/h

0 1 2 3 4 5 6 Q (l/s) 0 1 2 3 4 5 6 Q (l/s)
160 750 230
/11 /16
500 MPVN40.2/.. 150
700
MPVN40.2/.. 220

1750 RPM /15 1750 RPM 210


/10 140
200
450 650 /14
130 190
Total Head H (ft)
Total Head H (ft)

/9 600
400 /13 180
120
/8 550 /12 170
110
350 160

H (m)
500
H (m)

/7 100 150
300 90 140
450
130
80
400 120
250
P (KW)

70 110
P (KW)

350
200 60 100
300 90 16
HP

50 11 21
150 /16 15
14
HP

Impeller Dia. 170 mm /1 250


Impeller Dia. 170 mm
10 /15 19 14
/10 /14 13
12 9 17
HP /9 /13 12
8 HP
/8 10
/12 15 11
7 10
NPSHr /7 NPSHr 13
(m) (ft) 8 6 (m) (ft) 9
3 3 11
8 8 8
2 5 2
NPSH 6 7
9
1
4 4 1
4 NPSH 6
MP42/403-0 MP42/404-0
0 4 3 0 7 5
0 10 20 30 40 50 60 70 80 90 US GPM 0 10 20 30 40 50 60 70 80 90 US GPM
Capacity Q Capacity Q
0 2 4 6 8 10 12 14 16 18 20 22 m3/h 0 2 4 6 8 10 12 14 16 18 20 22 m3/h

PAGE 14
Goulds Water Technology
Commercial Water

SELECTION CHARTS: MPVN 40.3 n = 1750 RPM


Single Stage
0 1 2 3 4 5 6 7 8 Q (l/s) 0 1 2 3 4 5 6 7 8 Q (l/s)
15 85
Dia. 170 mm 280 /6 80
45 MPVN40.3/1 14 MPVN40.3/..
260 75
1750 RPM 13 1750 RPM
70
240
40 /5 65
12
Total Head H (ft)

Total Head H (ft)


220
Dia. 150 mm 11 60
35 200 55

H (m)
10 /4
180 50
30 9 45

H (m)
160
Dia. 130 mm 0 8 40
25 140 /3
35
7 120
30
20 6 100
1 /2 25
5 80 20
15
2 15
4 60

P (KW)
/1 10
Efficiency (%)

70 40
5
cy

HP
cien 10
60 Effi 7
P (KW)
/6
0 Impeller Dia. 170 mm
1 8 6
50 HP /5
HP

2 5
40 1.5 1.2 /4 6
0 4
NPSHr 1.3 1.0 NPSHr /3 4 3
(m) (ft) HP 1.1
(m) (ft) /2
3 10 0.8 3 10 2
1 2
8 0.9 8 /1 1
2 6
0.6 2 6
2 0.7 0 0
4 0 4
1 NPSH 0.5 0.4 1 NPSH
2 2
MP43/401-0 MP43/402-0
0 0
0 10 20 30 40 50 60 70 80 90 100 110 120 US GPM 0 10 20 30 40 50 60 70 80 90 100 110 120US GPM
Capacity Q Capacity Q
0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 m3/h 0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 m3/h

0 1 2 3 4 5 6 7 8 Q (l/s) 0 1 2 3 4 5 6 7 8 Q (l/s)
170 750 230
550 /16
/11
MPVN40.3/.. 160 MPVN40.3/.. 220
500 1750 RPM 150
700 /15 1750 RPM 210
/10 140 200
450 650 /14
Total Head H (ft)

Total Head H (ft)

130 190
/9
400 600 /13
120 180
H (m)

H (m)
/8
110 /12 170
350 550
/7 100 160
300 90 500 150

80 140
250 450
70 130
P (KW)

200 60 400 120


Impeller Dia. 170 mm
HP

13 110
P (KW)

/11 350
17
12 100
/10 Impeller Dia. 170 mm
15
HP

11 26 20
HP /9 10 /16 18
13 /15 22
/8 9 /14 16
HP /13
/7 11 8 /12 14
18
NPSHr NPSHr
(m) (ft) 7 (m) (ft) 12
9
3 10 3 10 14
6 10
8 8
2 6
7 5 2 6 8
10
4 4
1 NPS 5 4 1 NPSH 6
2 2
MP43/403-0 3 MP43/404-0
0 0
0 10 20 30 40 50 60 70 80 90 100 110 120 US GPM 0 10 20 30 40 50 60 70 80 90 100 110 120 US GPM
Capacity Q Capacity Q
0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 m3/h 0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 m3/h

PAGE 15
Goulds Water Technology
Commercial Water

MPVN STANDARD CONSTRUCTION MPVN40.2, MPVN40.3

A STANDARD CONSTRUCTION: Number of Stages


Code 00 Flange Location 1*) 2*) 3 4 5 6 7 8 9
a 3.94 6.10 8.27 10.43 12.60 14.76 16.93 19.09 21.26
(100) (155) (210) (265) (320) (375) (430) (485) (540)
b 8.27 10.43 12.60 14.76 16.93 19.09 21.26 23.43 25.59
ØBD (210) (265) (320) (375) (430) (485) (540) (595) (650)
10 11 12 13 14 15 16
H 13.78
AH (350) a 23.43 25.59 27.76 29.92 32.09 34.25 36.42
11.02 (595) (650) (705) (760) (815) (870) (925)
h (280) b 27.76 29.92 32.09 34.25 36.42 38.58 40.75
PM2 (705) (760) (815) (870) (925) (980) (1035)
L

NEMA HP (rpm)
DND

h H BD AH
C Motor 3550 1750
a
b PM1 254TD 15 15 15.51 34.69 14.02 4.00
(394) (881) (356) (101.6)
7.08 0.88 (22)
D 256TD 20 20 15.51 34.69 14.02 4.00
(180)
0.88 (22) (394) (881) (356) (101.6)
DNS

284TD – 25 15.51 37.44 14.02 4.62


(394) (881) (356) (117.3)
4.33 11.81 (300)
(110) 284TSD 25 – 15.51 37.44 14.02 3.25
(394) (881) (356) (82.5)
3.14 (80)
286TD – 30 15.51 37.44 14.02 4.62
19.69 (500) FOUNDATION BOLT (394) (881) (356) (117.3)
286TSD 30 – 15.51 37.44 14.02 3.25
ALTERNATIVE FLANGE LOCATIONS (394) (881) (356) (82.5)
324TSD 40 – 15.51 38.43 17.95 3.75
(394) (976) (456) (95.3)
326TSD 50 – 15.51 38.43 17.99 3.75
(394) (976) (457) (95.3)
364TSD 60 – 15.51 39.33 17.99 3.75
Code OO Code OR Code OL Code OG (394) (999) (457) (95.3)
365TSD 75 – 15.51 39.33 17.99 3.75
PUMP FLANGES
(394) (999) (457) (95.3)
ASME B16.5 405TSD 100 – 16.69 43.43 22.01 4.25
DN Class D K C d L No. of (424) (1103) (559) (108.0)
Holes
PM1 = Suction Gauge Conn. G1/4
6.14 3.86 0.87 2.87 5
⁄ 8
150 4 PM2 = Discharge Gauge Conn. G1/4
(156) (98) (22) (73) (16)
L = Vent Conn. G1/2
Discharge 300 6.14 4.49 0.87 2.87 7⁄8 4 D = Drain Conn. G1/4
11⁄2 (in.) (156) (114) (22) (73) (22)
*) = Code OO not possible, normal configuration code OG
600 7.01 4.49 1.10 2.87 5⁄8 4 Dimensions in inches (mm).
(178) (114) (28) (73) (16)
150 7.52 5.51 0.94 4.13 ⁄4
3
4
Suction (191) (140) (24) (105) (19)
21⁄2 (in.) 300 7.52 5.87 0.94 4.13 7⁄8 8
(191) (149) (24) (105) (22)
Dimensions in inches (mm)

PAGE 16
Goulds Water Technology
Commercial Water

SELECTION CHARTS MPVN 65.1 n = 3550 rpm


Single Stage
0 5 10 15 20 25 30 Q (l/s) 0 5 10 15 20 25 30 Q (l/s)
275 85 240
/3
Dia. 200 mm MPVN65.1/1 80 MPVN65.1/.. 220
250
3550 RPM 75
700 3550 RPM
200
70
225
Total Head H (ft)

Total Head H (ft)


600 180
Dia. 178 mm 65
200
60 /2 160
500

H (m)

H (m)
175 55
Dia. 155 mm 140
50
150 45 400 120

125 40
100
35 300
/1 80
100 0 30
1 25 200 60
Efficiency (%)

P (KW)
2

P (KW)
70 20
cy 40
en 100
60 ici
Eff

HP
80 60
50
1 0 HP 21 /3
2 Impeller Dia. 200 mm HP 70
40 0 26 19 50
60
17 40
HP 22
/2 50
15
1 40 30
18 13
NPSHr NPSHr 30
11 /1 20
(m) (ft) 2 14 (m) (ft) 20
6 20 9 6 20
0 10
4
15 10 4
15
NPSH 10
NPSH 7
10 10 0 0
2 5 2 5
MP65/301-0 MP65/302-0
0 0
0 50 100 150 200 250 300 350 400 450 500 US GPM 0 50 100 150 200 250 300 350 400 450 500 US GPM
Capacity Q Capacity Q
0 10 20 30 40 50 60 70 80 90 100 110 120 m3/h 0 10 20 30 40 50 60 70 80 90 100 110 120 m3/h

0 5 10 15 20 25 30 Q (l/s)
480
/6
1500 MPVN65.1/.. 460

1400 3550 RPM 440


420
1300 /5 400
380
Total Head H (ft)

1200
360
1100 340
/4
H (m)

320
1000
300
900 280
260
800 240

700 220
200
600 180
160
500
P (KW)

140
400 120
Impeller Dia. 200 mm
HP

120
/6 150 110
HP
100
/5 130
90
110 80
NPSHr /4
(m) (ft) 70
6
90
20
15
60
4 NPSH 70
10
50
2 5 50 40
MP65/303-0
0
0 50 100 150 200 250 300 350 400 450 500 US GPM
Capacity Q
0 10 20 30 40 50 60 70 80 90 100 110 120 m3/h

PAGE 17
Goulds Water Technology
Commercial Water

SELECTION CHARTS MPVN 65.2 n = 3550 RPM


Single Stage
0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 Q (l/s) 0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 Q (l/s)
90 280
900
280 Dia. 200 mm MPVN65.2/1 85 /3 MPVN65.2/.. 260

260 3550 RPM 80 800 3550 RPM 240


75 220
240 700
Total Head H (ft)

Total Head H (ft)


70 200
220 600
Dia. 178 mm 65 180
/2

H (m)

H (m)
200 160
60
500
180 55 140

Dia. 155 mm 50 400 120


160
0 45 100
140 300 /1

P (KW)
40 80
120
35 200 60
1
100 120

HP
30 90
Impeller Dia. 200 mm /3
2 25 80
100
ncy
P (KW)
70 70
Efficiency (%)

icie HP
60 Eff 80 60
1 0 /2
HP

50 2 30 50
0 40
60
40 25 40
HP 32
30 20 /1 40 30
1 24
NPSHr 0
15 NPSHr 20
(m) (ft) 2 16 (m) (ft) 20
6 20 10 6 20 10
15
NPSH 8 15
NPSH
4 5 4 0 0
10 10
2 0 0 2
5 5
MP66/301-0 MP66/302-0
0 0
0 50 100 150 200 250 300 350 400 450 500 550 600 US GPM 0 50 100 150 200 250 300 350 400 450 500 550 600 US GPM
Capacity Q Capacity Q
0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 m3/h 0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 m3/h

0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 Q (l/s)
540
1700 /6 MPVN65.2/.. 520

1600
3550 RPM 500
480
1500 460
440
1400 /5
420
Total Head H (ft)

1300 400
380
H (m)

1200
360
/4 340
1100
320
1000
300
900 280
260
800 240
Impeller Dia. 200 mm
220
700
P (KW)

200
600 180
HP

180
/6 220
160
/5 140
HP 180
120
/4
140 100
NPSHr
(m) (ft) 100 80
6 20
60
15 NPSH
4 60 40
10
2 5
MP66/303-0
0
0 50 100 150 200 250 300 350 400 450 500 550 600 US GPM
Capacity Q
0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 m3/h

PAGE 18
Goulds Water Technology
Commercial Water

SELECTION CHARTS MPVN 65.1 n = 1750 RPM


Single Stage
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Q (l/s) 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Q (l/s)
21 85

65 Dia. 200 mm MPVN65.1/1 20


260 /4 MPVN65.1/.. 80
1750 RPM 19 1750 RPM 75
60 18 240
70
55 17 220
65
16
Dia. 178 mm 200
Total Head H (ft)

50 /3 60

Total Head H (ft)


15

H (m)
14 180 55
45
50

H (m)
13 160
40 45
Dia. 155 mm 12
140
35 11 /2 40
10 120 35
30 9 100 30
8
25 0 80 25
7
/1 20
20 6 60
1

P (KW)
15
Efficiency (%)

2 40 Impeller Dia. 200 mm


10
70
iency
Effic P (KW)

HP
60 10
/4
HP
50 8
HP

1 0 10
40 2 2.5 /3
0 6
HP 3 2.0 /2 6 4
NPSHr 1 NPSHr
2 1.5 (m) (ft) /1
(m) (ft) 2 2
3 10 1.0 3 10 2
8 1 8 0
2 0.5 2
6 NPSH 0 6 NPSH
4 4
1 1
2 2
MP65/401-0 MP65/402-0
0 0
0 20 40 60 80 100 120 140 160 180 200 220 240 260 US GPM 0 20 40 60 80 100 120 140 160 180 200 220 240 260 US GPM
Capacity Q Capacity Q

0 5 10 15 20 25 30 35 40 45 50 55 60 m3/h 0 5 10 15 20 25 30 35 40 45 50 55 60 m3/h

0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Q (l/s) 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Q (l/s)
160 240
/8 /12
500 MPVN65.1/.. 750 MPVN65.1/.. 230
150
1750 RPM /11 1750 RPM 220
700
140 210
450 /7
650 /10 200
130 190
600 180
/9
Total Head H (ft)

Total Head H (ft)

400
/6 120 170
550
160
H (m)

H (m)
110 500
350 150
/5 100 450 140
130
300 90 400 120

350 110
80
250 100
300 90
70
P (KW)

80
250
200 60 70
200 30
HP

Impeller Dia. 200 mm 40


P (KW)

50 Impeller Dia. 200 mm /1


150 28
36
40 HP /11 26
20 32 24
/10
HP

/8 26 18 22
HP /7 22 16 /9 28
20
NPSHr /6 14 NPSHr
(m) (ft) 18 (m) (ft) 24 18
3 /5 12 3
10 10
14 16
8 10 8 20
2 6 2 6 14
NPSH 10 8 NPSH
4 4
1 6 1 16 12
2 2
MP65/403-0 6 4
MP65/404-0
0 0
0 20 40 60 80 100 120 140 160 180 200 220 240 260 US GPM 0 20 40 60 80 100 120 140 160 180 200 220 240 260 US GPM
Capacity Q Capacity Q
0 5 10 15 20 25 30 35 40 45 50 55 60 m3/h 0 5 10 15 20 25 30 35 40 45 50 55 60 m3/h

PAGE 19
Goulds Water Technology
Commercial Water

SELECTION CHARTS MPVN 65.2 n = 1750 RPM


Single Stage
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 Q (l/s) 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 Q (l/s)
22 90
70 Dia. 200 mm
MPVN65.2/1 21 280 /4 MPVN65.2/.. 85

65
1750 RPM 20 260 1750 RPM 80
19 75
60 240
18 70
Total Head H (ft)

Total Head H (ft)


17 220
55 /3 65
Dia. 178 mm 16 200 60

H (m)

H (m)
50 15 180 55
45 14
160 50
13
45
40 Dia. 155 mm 140 /2
12
0 40
11 120
35 35
10
100 30
30 9
1 80 25
8 /1
25 20
7 60

P (KW)
P (KW)
2 15
40 Impeller Dia. 200 mm
Efficiency (%)

HP
70 ncy 20
icie
HP

60 Eff 0 4.0 /4 18 14
1 5 16 12
50 2 0 3.5
HP /3 14 10
40 4 3.0
12
HP 8
2.5 10
NPSHr 1 3 NPSHr /2
2.0 8 6
(m) (ft) (m) (ft)
2 2 6 4
6 20 1.5 6 20 /1
15 15
4
4 1.0 4 2
10 0 1 10 2
2 NPSH 0.5 2 NPSH 0
5 5
MP66/401-0 MP66/402-0
0 0
0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 US GPM 0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 US GPM
Capacity Q Capacity Q
0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 m3/h 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 m3/h

0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 Q (l/s) 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 Q (l/s)
180 850 260
/12
MPVN65.2/.. MPVN65.2/.. 250
550 /8 170
1750 RPM 800 1750 RPM 240
160 /11
750 230
500
/7 150
220
Total Head H (ft)

700 /10
140
Total Head H (ft)

450 210

130 650 200


/6
/9
400 190
H (m)
H (m)

120
600
180
110
350 /5 550 170
100 160
500
Impeller Dia. 200 mm
300 90 150
Impeller Dia. 200 mm
80 450 140
250
P (KW)

130
P (KW)

70
400 120
200 60 30
HP

60 45
40
HP

/8
26 /12 55 40
/7 35 /11 50
HP
22 /10 35
30 45
/6 HP /9
40 30
NPSHr /5 25 18 NPSHr
(m) (ft) (m) (ft) 35
25
6 20 20 6 20
14 30
15 4 15 20
4
NPSH 15 25
10 10 10
NPSH 15
2 5 2 5
MP66/403-0 10 MP66/404-0
0 6 0
0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 US GPM 0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 US GPM
Capacity Q Capacity Q

0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 m3/h 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 m3/h

PAGE 20
Goulds Water Technology
Commercial Water

MPVN STANDARD CONSTRUCTION MPVN65.1, MPVN65.2

A STANDARD CONSTRUCTION: Number of Stages


Code 00 Flange Location 1*) 2*) 3 4 5 6 7 8 9
a 4.92 7.68 10.43 13.19 15.94 18.70 21.46 24.21 26.97
(125) (195) (265) (335) (405) (475) (545) (615) (685)
b 10.63 13.39 16.14 18.90 21.65 24.41 27.17 29.92 32.68
ØBD (270) (340) (410) (480) (550) (620) (690) (760) (830)
10 11 12
H 16.14
AH (410) a 29.72 32.48 35.24
13.39 (755) (825) (895)
h (340) b 35.43 38.19 40.94
PM2 (900) (970) (1040)
L

NEMA HP (rpm)
DND

h H BD AH
C Motor 3550 1750
a
b 254TD 15 15 16.89 36.06 14.02 4.00
(429) (916) (356) (101.6)
8.27 0.91 16.89 36.06 14.02 4.00
5.71 (145)

D (210) ø (23) 256TD 20 20


0.95 (24) (429) (916) (356) (101.6)
16.89 38.82 14.02 4.62
DNS

284TD – 25
(429) (986) (356) (117.3)
11.81 (300) 16.89 38.82 14.02 3.25
284TSD 25 –
(429) (986) (356) (82.5)
16.89 38.82 14.02 4.62
3.15 (80) 286TD – 30
(429) (986) (356) (117.3)
22.83 (580) FOUNDATION BOLT
16.89 38.82 14.02 3.25
286TSD 30 –
(429) (986) (356) (82.5)
ALTERNATIVE FLANGE LOCATIONS 18.07 40.98 17.99 5.25
324TD – 40
(459) (1041) (457) (133.4)
16.89 39.80 17.99 3.75
324TSD 40 –
(429) (1011) (457) (95.3)
18.07 40.98 17.99 5.25
326TD – 50
(459) (1041) (457) (133.4)
Code OO Code OR Code OL Code OG 16.89 39.80 17.99 3.75
326TSD 50 –
(429) (1011) (457) (95.3)
16.89 40.71 17.99 3.75
PUMP FLANGES 364TSD 60 –
(429) (1034) (457) (95.3)
ASME B16.5 18.07 41.89 17.99 5.88
365TD – 75
DN Class D K C d L z (459) (1064) (457) (149.4)
16.89 40.71 17.99 3.75
365TSD 75 –
(429) (1034) (457) (95.3)
150 7.52 5.51 0.94 4.13 ⁄4
3

4 18.07 44.80 22.01 4.25


(191) (140) (24) (105) (19) 405TSD 100 –
(459) (1138) (559) (108.0)
Discharge 300 7.52 5.87 0.94 4.13 7⁄8 8 18.07 49.21 22.01 4.75
21⁄2 (in.) (191) (149) (24) (105) (22) 444TSD 125 –
(459) (1250) (559) (120.7)
600 8.07 5.87 1.10 4.13 7⁄8 18.07 49.21 22.01 4.75
8
(205) (149) (28) (105) (22) 445TSD 150 –
(459) (1250) (559) (120.7)
150 9.25 7.52 1.06 6.18 ⁄4
3
8 18.07 49.21 22.01 4.75
Suction (235) (191) (27) (157) (19) 447TSD 200 –
(459) (1250) (559) (120.7)
4 (in.) 300 10.00 7.87 1.06 6.18 7⁄8 PM1 = Suction Gauge Conn. G1/4
8
(254) (200) (27) (157) (22) PM2 = Discharge Gauge Conn. G1/4
Dimensions in inches (mm). L = Vent Conn. G1/2
D = Drain Conn. G1/4
*) = Code OO not possible, normal configuration code OG
Dimensions in inches (mm).

PAGE 21
Goulds Water Technology
Commercial Water

SELECTION CHARTS MPVN 100.1 n = 3550 RPM

Single Stage

0 10 20 30 40 50 60 Q (l/s) 0 10 20 30 40 50 60 Q (l/s)
130 1800 550
400 Dia. 240 mm
MPVN100.1/1 120 /4
MPVN100.1/. 500
3550 RPM 1600 3550 RPM
350 110 450
Total Head H (ft)

Dia. 220 mm 1400


100
400
300 90 1200 /3

H (m)

H (m)
Dia. 200 mm 350

Total Head H (ft)


80
250 1000 300
70
800 /2 250
200 0 60
200
50 600
150 1
150

P (KW)
2 40 /1
Efficiency (%)

n cy 400
icie
70 Eff 100

P (KW)
60 200 260
50
0

HP
/4 330
Impeller Dia. 240 mm
HP

2 1 70
50 220
0 HP 270
80 60 /3 180
HP
50 210
1 140
60
NPSHr 40 NPSHr /2
2 150
(m) (ft) (m) (ft) 100
8 40 30 8
25 0 25
90
/1 60
6 20 NPSH 20 6 20
20 30
4 15 4 15 NPSH 20
10
10 10
2 0 0 2
5 5
MP101/301-0 MP101/302-0
0 0
0 100 200 300 400 500 600 700 800 900 1000 US GPM 0 100 200 300 400 500 600 700 800 900 1000 US GPM
Capacity Q Capacity Q
0 20 40 60 80 100 120 140 160 180 200 220 m3/h 0 20 40 60 80 100 120 140 160 180 200 220 m3/h

PAGE 22
Goulds Water Technology
Commercial Water

SELECTION CHARTS MPVN 100.2 n = 3550 RPM

Single Stage

0 10 20 30 40 50 60 70 Q (l/s) 0 10 20 30 40 50 60 70 Q (l/s)
140 1300 400
/3
440 Dia. 240 mm MPVN100.2/1 130 MPVN100.2/. 380
400 3550 RPM 1200 3550 RPM 360
120
1100 340
Total Head H (ft)

Total Head H (ft)


360 110
320
Dia. 220 mm 100 1000
320 300

H (m)

H (m)
90 280
280 900
Dia. 200 mm 0 /2 260
80
240 800 240
70
1 220
200 60 700
200
160 2 50 600 180
160
500
80 140
/1
Efficiency (%)

cy
cien 0 400
70 Effi 120

P (KW)
2 1

P (KW)
100
60 300
80
HP

HP
50 0 80 Impeller Dia. 240 mm 320
100 200 240
HP /3 280
40 70
HP 200
240
80 60 200 160
/2
1
50 160 120
60 120
2 40 /1 80
NPSHr NPSHr 100
(m) (ft) (m) (ft) 70
40 30 90
15 50 0 15 50 80 60
40 20 40
10 10
30 NPSH 20 30
20 NPSH
5 10 5 20
10 10
MP102/301-0 MP102/302-0
0 0
0 100 200 300 400 500 600 700 800 900 1000 1100 1200 US GPM 0 100 200 300 400 500 600 700 800 900 1000 1100 1200 US GPM
Capacity Q Capacity Q
0 20 40 60 80 100 120 140 160 180 200 220 240 260 m3/h 0 20 40 60 80 100 120 140 160 180 200 220 240 260 m3/h

PAGE 23
Goulds Water Technology
Commercial Water

SELECTION CHARTS MPVN 100.1 n = 1750 RPM


Single Stage
0 5 10 15 20 25 30 35 Q (l/s) 0 5 10 15 20 25 30 35 Q (l/s)

110 35 130
/4
100 Dia. 240 mm MPVN100.1/1
400 MPVN100.1/.. 120
30
90 1750 RPM 1750 RPM 110
Dia. 220 mm 25 350
80
Total Head H (ft)

100

H (m)

H (m)
70 Dia. 200 mm /3
20 300 90
60

Total Head H (ft)


50 15 80
0 250
40 70
30 1 10 /2
2 200 60
20
5 50
150
70 cy 40
Efficiency (%)

0
ien
fic /1
60 Ef 100 30

P (KW)
20

P (KW)
0

HP
50 50
1 10
2 11 45

HP
40 8 32
0 0 /4
Impeller Dia. 240 mm 40
7 28
9 HP 35
HP 24
6 /3
1 30
20
7
5 25
16
2 /2 20
NPSHr 5 4 NPSHr 12
(m) (ft) (m) (ft) 15
/1 8
3 10 3 3 10 10
0
8 8
5 4
2 3 2
6 2 6
NPSH NPSH 0 0
4 4
1 1 1
2 2
MP101/401-0 MP101/402-0
0 0
0 50 100 150 200 250 300 350 400 450 500 550 US GPM 0 50 100 150 200 250 300 350 400 450 500 550 US GPM
Capacity Q Capacity Q
0 10 20 30 40 50 60 70 80 90 100 110 120 130 m3/h 0 10 20 30 40 50 60 70 80 90 100 110 120 130 m3/h

0 5 10 15 20 25 30 35 Q (l/s)
260
800 /8 MPVN100.1/.. 240
1750 RPM
/7 220
700
Total Head H (ft)

200
H (m)

600 /6 180

160
500 /5
140
400 120

100
P (KW)

300
80
HP

200 90 65
/8
60
80
Impeller Dia. 240 mm
/7 55
HP 70
50
/6
60 45
40
/5
50
35
NPSHr
(m) (ft) 40 30
3 10
25
8 30
2
6 NPSH 20
4 20
1 10
2
MP101/403-0
0
0 50 100 150 200 250 300 350 400 450 500 550 US GPM
Capacity Q
0 10 20 30 40 50 60 70 80 90 100 110 120 130 m3/h

PAGE 24
Goulds Water Technology
Commercial Water

SELECTION CHARTS MPVN 100.2 n = 1750 RPM


Single Stage
0 5 10 15 20 25 30 35 40 Q (l/s) 0 5 10 15 20 25 30 35 40 Q (l/s)
35 450 140
110
Dia. 240 mm MPVN100.2/1 /4 130
100
1750 RPM MPVN100.2/..
Total Head H (ft)

30 400
90 1750 RPM 120

80 Dia. 220 mm 25 110


350
70 /3 100
Dia. 200 mm 20
60 300 90

H (m)

H (m)
Total Head H (ft)
50 15 80
0 250
40 70
10 /2
30 1 200 60
2
80 5 50
n cy 150
icie

P (KW)
40
Efficiency (%)

70 Eff /1

P (KW)
100 30
60 14 20

HP
0 50
1 10 45
50 16 12
/4 55

HP
2 0 40
0 Impeller Dia. 240 mm HP
40 10 35
45
HP 12 /3 30
8
35 25
1
NPSHr 8 6 NPSHr /2 20
(m) (ft) (m) (ft) 25
2 15
6 20 4 6 20
15
/1 10
4
15 0 15
4 2 4 5
5
10 NPSH 10 0
2 0 0 2 NPSH
5 5
MP102/401-0 MP102/402-0
0 0
0 100 200 300 400 500 600 700 US GPM 0 100 200 300 400 500 600 700 US GPM
Capacity Q Capacity Q
0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 m3/h 0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 m3/h

0 5 10 15 20 25 30 35 40 Q (l/s)
260
850 /8
MPVN100.2/.. 240
800 1750 RPM
750 /7 220

700
200
H (m)
Total Head H (ft)

650
/6
180
600

550 160
/5
500 140
450
120
400

350 100

300 Impeller Dia. 240 mm


80
P (KW)

250
HP

90
/8 110 80
HP
/7 90 70
/6 60
70
NPSHr /5 50
(m) (ft) 50 40
6 20 30
4 15 30 20
10 NPSH
2
5
MP102/402-0
0
0 100 200 300 400 500 600 700 US GPM
Capacity Q
0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 m3/h

PAGE 25
Goulds Water Technology
Commercial Water

MPVN STANDARD CONSTRUCTION MPVN100.1, MPVN100.2


A STANDARD CONSTRUCTION: Number of Stages
Code 00 Flange Location 1*) 2*) 3 4 5
a 6.89 10.24 13.58 16.93 20.28
(175) (260) (345) (430) (515)
b 13.19 16.54 19.88 23.23 26.57
ØBD (335) (420) (505) (590) (675)
6 7 8
H 18.89
AH (480) a 23.62 26.97 30.31
16.14 (600) (685) (770)
h (410) b 29.92 33.27 36.61
PM2 (760) (845) (815)
L
NEMA HP (rpm)
h H BD AH
DND

Motor 3550 1750


C
a 254TD – 15 19.06 38.23 14.02 4.00
b (484) (971) (356) (101.6)
19.06 38.23 14.02 4.00
27.95 (160)

9.84 1.06 256TD – 20


(484) (971) (356) (101.6)
D (250) ø (27)
1.18 19.06 40.98 14.02 4.00
284TD – 25
DNS

(30) (484) (1041) (356) (101.6)


19.06 40.98 14.02 4.00
286TD – 30
(484) (1041) (356) (101.6)
11.81 (300)
20.24 43.15 17.99 5.25
324TSD – 40
(514) (1096) (457) (133.4)
3.15 (80)
27.56 (700) FOUNDATION BOLT 20.24 43.15 17.99 5.25
326TD – 50
(514) (1096) (457) (133.4)
20.24 44.06 17.99 5.88
364TD – 60
(514) (1119) (457) (149.4)
ALTERNATIVE FLANGE LOCATIONS
19.06 42.87 17.99 3.75
364TSD 60 –
(484) (1089) (457) (95.3)
19.06 44.06 17.99 5.88
365TD – 75
(484) (1119) (457) (149.4)
20.24 42.87 17.99 3.75
365TSD
75 – (514) (1089) (457) (95.3)
Code OO Code OR Code OL Code OG
19.06 48.35 22.01 7.25
405TD
– 100 (484) (1228) (559) (184.2)
PUMP FLANGES
21.61 46.97 22.01 4.25
ASME B16.5 405TSD 100 –
(514) (1193) (559) (108.0)
DN Class D K C d L z 20.24 51.38 22.01 4.75
444TSD 125 –
(514) (1305) (559) (120.7)
150 9.25 7.52 1.06 6.14 ⁄4 445TSD 150 – 20.24 51.38 22.01 4.75
3

8 (514) (1305) (559) (120.7)


(235) (191) (27) (156) (19)
Discharge 300 10.75 7.87 1.26 6.14 7⁄8 8 447TSD 200 – 20.24 55.39 22.01 4.75
4 (in.) (273) (200) (32) (156) (22) (514) (1407) (559) (120.7)
600 10.75 8.50 1.26 6.14 1 449TSD 250 – 20.24 58.39 22.01 4.75
8 (514) (1483) (559) (120.7)
(273) (216) (32) (156) (25)
449TSD 300 – 20.24 58.39 22.01 4.75
150 10.98 8.50 1.14 7.24 ⁄8
7
8 (514) (1483) (559) (120.7)
Suction (279) (216) (29) (184) (22)
449TSD 350 – 20.24 58.39 22.01 4.75
5 (in.) 300 10.98 9.25 1.14 7.24 7⁄8 (514) (1483) (559) (120.7)
8
(279) (235) (29) (184) (22) PM1 = Suction Gauge Conn. G1/4
Dimensions in inches (mm) PM2 = Discharge Gauge Conn. G1/4
L = Vent Conn. G1/2
D = Drain Conn. G1/4
*) = Code OO not possible, normal configuration code OG
Dimensions in inches (mm).
PAGE 26
Goulds Water Technology
Commercial Water

SELECTION CHARTS MPVN 125.1 n = 3550 RPM

Single Stage
0 10 20 30 40 50 60 70 80 90 100 Q (l/s) 0 10 20 30 40 50 60 70 80 90 100 Q (l/s)
180 1700 525
/3
Dia. 275 mm 500
550 MPVN125.1/1 170 1600 MPVN125.1/. 475
3550 RPM 160 1500 3550 RPM 450
500
150 1400 425
Dia. 255 mm 140 1300 400
450
375
130 1200
Total Head H (ft)

Total Head H (ft)


H (m)

H (m)
400 /2 350
120 1100
Dia. 235 mm 325
110 1000 300
350 0
100 900 275
Dia. 215 mm
800 250
300 90
225
1 80
700
250 200
600 /1 175
2 70

P (KW)
500 150
200 60
3 400 125
80

P (KW)
50
Efficiency (%)

cy 100 460
300
70 ic ien 1 0 580
HP

HP
/3
Eff 2
Impeller Dia. 275 mm
420
60 3 0 190 140 500 380
340
50 120 HP 420
HP 150 300
40 1 100 /2
340 260
NPSHr 2 110 80 220
(m) (ft) NPSHr
3 260 180
15 50 60 (m) (ft)
40 0 70 140
10
15 50 /1
30 40 40 180
NPSH 10 30
100
5
20 30 20 20
NPSH
10 5
MP126/301-0 10 MP125/302-0
0 0
0 200 400 600 800 1000 1200 1400 1600 US GPM 0 200 400 600 800 1000 1200 1400 1600 US GPM
Capacity Q Capacity Q
0 50 100 150 200 250 300 350 m3/h 0 50 100 150 200 250 300 350 m3/h

PAGE 27
Goulds Water Technology
Commercial Water

SELECTION CHARTS MPVN 125.2 n = 3550 RPM


Single Stage
0 10 20 30 40 50 60 70 80 90 100 110 Q (l/s) 0 10 20 30 40 50 60 70 80 90 100 110 Q (l/s)
1700
540 Dia. 275 mm 170 /3
MPVN125.2/1 1600 MPVN125.2/. 500
500
3550 RPM 160 1500 3550 RPM
460
150 1400
460 420
1300
Dia. 255 mm 140
Total Head H (ft)

Total Head H (ft)


420 1200 380

H (m)

H (m)
130
1100 /2
380 340
120 1000
Dia. 235 mm
110 300
340 900
0
100 800 260
300 Dia. 215 mm
700
1 90 220
260 600
/1

P (KW)
80 180
500
220 2 70 400 140
480
Efficiency (%)

60 300 /3 600 440

HP
3 Impeller Dia. 275 mm
P (KW)

80 HP 400
ncy 1 0 520
70 cie 2 50
Effi
360
60 3
440 320
50 220 160 /2
HP

0 280
HP 140 360
180 240
NPSHr 120 NPSHr
(m) (ft) 1 140 100 (m) (ft)
280 200
16 2 80 16 /1 160
50 100 50 200
12 40 3 0 60 12 40 120
8 30 NPSH 60 40 8 30 NPSH 120 80
20 20
4 4
10 MP125/301-0 10 MP126/302-0
0 0
0 200 400 600 800 1000 1200 1400 1600 1800 US GPM 0 200 400 600 800 1000 1200 1400 1600 1800 US GPM
Capacity Q Capacity Q
0 50 100 150 200 250 300 350 400 m3/h 0 50 100 150 200 250 300 350 400 m3/h

PAGE 28
Goulds Water Technology
Commercial Water

SELECTION CHARTS MPVN 125.1 n = 1750 RPM


Single Stage
0 5 10 15 20 25 30 35 40 45 50 55 60 Q (l/s) 0 5 10 15 20 25 30 35 40 45 50 55 60 Q (l/s)
44 180
140 Dia. 275 mm 580
42 /4 170
MPVN125.1/1 40 540 MPVN125.1/..
130 160
1750 RPM 38 500 1750 RPM
150
120 36 460 140
110 Dia. 255 mm 34 420 /3 130
32
380 120
100
Total Head H (ft)

Total Head H (ft)


30
110

H (m)

H (m)
Dia. 235 mm 28 340
90 100
26 300
80 /2 90
Dia. 215 mm 24
260 80
70 22
70
0 20 220
60 60
18 180
50
1 16 140 /1
50 40
14
2 100 30
40

P (KW)
12
60 20
3 10

P (KW)
Efficiency (%)

80
HP Impeller Dia. 275 mm 100

HP
cy /4 70
70
icien 80 60
60 Eff 1 0 20
2 26
HP /3
50 3 18 50
0 60
40 22 16 40
HP /2
14 40 30
NPSHr 1 18 NPSHr 20
(m) (ft) 0 12 (m) (ft) /1 20
5 2 14 10 5 10
15 15
4 3 8 4 0 0
10
3 10 6 3 10
NPSH 6 NPSH
2 4 2
5 5
1 1
MP125/401-0 MP125/402-0
0 0
0 100 200 300 400 500 600 700 800 900 US GPM 0 100 200 300 400 500 600 700 800 900 US GPM
Capacity Q Capacity Q
0 20 40 60 80 100 120 140 160 180 200 220 m3/h 0 20 40 60 80 100 120 140 160 180 200 220 m3/h

0 5 10 15 20 25 30 35 40 45 50 55 60 Q (l/s)
320
1000
/7 MPVN125.1/.. 300

900 1750 RPM 280


/6 260
800
Total Head H (ft)

240

700 /5 220
H (m)

200
600 180
160
500
140
400 120

100
300
P (KW)

Impeller Dia. 275 mm


HP

180 130
/7 120
160
110
HP /6 140
100
NPSHr /5 120 90
(m) (ft)
5 80
15 100
4 70
3 10 80 60
NPSH
2 50
5 60
1 40
MP125/403-0
0
0 100 200 300 400 500 600 700 800 900 US GPM
Capacity Q
0 20 40 60 80 100 120 140 160 180 200 220 m3/h

PAGE 29
Goulds Water Technology
Commercial Water

SELECTION CHARTS MPVN 125.2 n = 1750 RPM


Single Stage
0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 Q (l/s) 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 Q (l/s)
550
Dia. 275 mm 42
/4 170
130
MPVN125.2/1 40 500
MPVN125.2/..
160
120 1750 RPM 38 1750 RPM
150
450
110 36
Dia. 255 mm 140
34 /3
400 130
100 32
120
Total Head H (ft)

Total Head H (ft)


30 350

H (m)
90 Dia. 235 mm
28 110
80 300 100

H (m)
26
Dia. 215 mm /2 90
24
70 250
22 80
60 20
0 200 70
18 60
50
16 150 /1
1 50
40 14

P (KW)
100 40
2 12
Efficiency (%)

3 10 30
80 50
P (KW)
n cy 80
70 icie 8 /4
Eff Impeller Dia. 275 mm 100

HP
60 1 0 HP 70
HP

50 3 2 20 60
0 /3 80
24 18 50
HP 16 60
20 /2 40
1 14 NPSHr
NPSHr 40 30
(m) (ft) 16 12 (m) (ft)
8 2 10
8 25 /1 20
25 0 20
12 5 20 10
5 20 3 8
15 4 15 0 0
4 8 6 NPSH
10 NPSH 10
2 2 5
5
MP126/401-0 MP126/402-0
0 0
0 100 200 300 400 500 600 700 800 900 1000 1100 US GPM 0 100 200 300 400 500 600 700 800 900 1000 1100 US GPM
Capacity Q Capacity Q
0 20 40 60 80 100 120 140 160 180 200 220 240 260 m3/h 0 20 40 60 80 100 120 140 160 180 200 220 240 260 m3/h

0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 Q (l/s)
300
950 /7
900
MPVN125.2/.. 280
850
1750 RPM
260
800 /6
240
750
700 220
/5
Total Head H (ft)

650 200
600 180
H (m)

550
160
500
450 140
400 120
P (KW)

350
100
300
140
HP

250 /7
Impeller Dia. 275 mm 180
130

HP 160 120
/6
110
140
/5 100
NPSHr
(m) (ft)
8 25 120 90

5 20 80
100
15
4 70
10 NPSH
2 80 60
5
MP126/403-0
0
0 100 200 300 400 500 600 700 800 900 1000 1100 US GPM
Capacity Q
0 20 40 60 80 100 120 140 160 180 200 220 240 260 m3/h

PAGE 30
Goulds Water Technology
Commercial Water

MPVN STANDARD CONSTRUCTION MPVN125.1, MPVN125.2


A STANDARD CONSTRUCTION: Number of Stages
Code 00 Flange Location 1*) 2*) 3 4 5 6 7
a 8.66 12.80 16.93 21.06 25.20 29.33 33.46
(220) (325) (430) (535) (640) (745) (850)
b 15.75 19.88 24.02 28.15 32.28 36.42 40.55
ØBD (400) (505) (610) (715) (820) (925) (1030)

H 22.05
AH (560)
19.29 NEMA HP (rpm)
h (490) h H BD AH
Motor 3550 1750
PM2
23.50 47.13 17.99 5.25
L 324TD – 40
(597) (1197) (457) (133.4)
23.50 47.13 17.99 5.25
326TD – 50
DND

(597) (1197) (457) (133.4)


C 23.50 47.32 17.99 5.88
a 364TD – 60
b (597) (1202) (457) (149.4)
23.50 47.32 17.99 5.88
11.81 1.06 365TD – 75
7.07 (180)

D (597) (1202) (457) (149.4)


(300) ø (27)
1.38 25.98 52.72 22.01 7.25
405TD – 100
DNS

(35) (660) (1339) (559) (184.2)


23.50 50.35 22.01 4.25
11.81 (300) 405TSD 100 –
(597) (1279) (559) (108.0)
25.98 57.13 22.01 8.50
444TD – 125
3.15 (80) (660) (1451) (559) (215.9)
31.50 (800) FOUNDATION BOLT 23.50 54.65 22.01 4.75
444TSD 125 –
(597) (1388) (559) (120.7)
23.50 57.13 22.01 8.50
ALTERNATIVE FLANGE LOCATIONS 445TD – 150
(660) (1451) (559) (215.9)
25.98 54.65 22.01 4.75
445TSD 150 –
(597) (1388) (559) (120.7)
23.50 61.14 22.01 8.50
447TD – 200
(660) (1553) (559) (215.9)
Code OO Code OR Code OL Code OG 25.98 58.66 22.01 4.75
447TSD 200 –
(597) (1490) (559) (120.7)
25.98 64.13 22.01 8.50
PUMP FLANGES 449TD – 250
(660) (1629) (559) (215.9)
ASME B16.5 23.50 61.65 22.01 4.75
449TSD 250 –
DN Class D K C d L z (597) (1566) (559) (120.7)
23.50 61.65 22.01 4.75
449TSD 300 –
(597) (1566) (559) (120.7)
150 10.98 8.50 1.14 7.24 ⁄8
7

8
(279) (216) (29) (184) (22) 23.50 61.65 22.01 4.75
449TSD 350 –
Discharge 300 10.98 9.25 1.14 7.24 7⁄8 (597) (1566) (559) (120.7)
8 23.50 61.65 22.01 4.75
5 (in.) (279) (235) (29) (184) (22) 449TSD 400 –
600 12.99 10.51 1.38 7.24 11⁄8 (597) (1566) (559) (120.7)
8 23.50 69.80 25.00 4.75
(330) (267) (35) (184) (29) 500TSD 500 –
(630) (1773) (635) (120.7)
150 11.81 9.49 1.26 8.31 ⁄8
7
8
Suction (300) (241) (32) (211) (22) PM1 = Suction Gauge Conn. G1/4
6 (in.) 300 12.48 10.63 1.26 8.31 7⁄8 PM2 = Discharge Gauge Conn. G1/4
12 L = Vent Conn. G1/2
(317) (270) (32) (211) (22)
Dimensions in inches (mm)
D = Drain Conn. G1/4
*) = Code OO not possible, normal configuration code OG
Dimensions in inches (mm).

PAGE 31
Xylem
1) The tissue in plants that brings water upward from the roots;
2) a leading global water technology company.

We’re 12,500 people unified in a common purpose: creating innovative solutions


to meet our world’s water needs. Developing new technologies that will improve
the way water is used, conserved, and re-used in the future is central to our work.
We move, treat, analyze, and return water to the environment, and we help people
use water efficiently, in their homes, buildings, factories and farms. In more than
150 countries, we have strong, long-standing relationships with customers who
know us for our powerful combination of leading product brands and applications
expertise, backed by a legacy of innovation.

For more information on how Xylem can help you, go to www.xyleminc.com

Xylem, Inc.
2881 East Bayard Street Ext., Suite A
Seneca Falls, NY 13148
Phone: (800) 453-6777
Fax: (888) 322-5877
www.xyleminc.com/brands/gouldswatertechnology
Goulds is a registered trademark of Goulds Pumps, Inc. and is used under license.
© 2012 Xylem Inc. BMPVN R1 December 2012