E85001-0650 - Intelligent Multisensor Smoke and Heat Detector
E85001-0650 - Intelligent Multisensor Smoke and Heat Detector
E85001-0650 - Intelligent Multisensor Smoke and Heat Detector
Intelligent
Multisensor Smoke
and Heat Detector
SIGA-PHD
S853
Like all Signature Series detectors, the SIGA-PHD gathers analog • Sensor Markings Provide Easy Testing Identification
information from its sensing elements and converts this data into • Up To 250 Total Signature Adresses Per Loop
digital signals. To make an alarm decision, the detector’s on-board
microprocessor measures and analyzes smoke and heat sensor • Two levels of environmental compensation
readings and compares this information to historical data. Digital • Two levels of dirty detector warning
filters remove signal patterns that are not typical of fires, thus virtu-
ally eliminating unwanted alarms. • Twenty pre-alarm settings
• Five sensitivity settings
• Non-volatile memory
• Electronic addressing
• Environmental compensation
• Automatic day/night sensitivity adjustment
• Bicolor (green/red) status LED
• Standard, relay, fault isolator, and audible mounting bases
This base includes a built-in line fault isolator for use on Class A
circuits. A detector must be installed for it to operate. The isolator
base does not support the SIGA-LED Remote LED.
The isolator operates as follows: Warnings & Cautions
- a short on the line causes all iso- • This detector does not operate without electrical power. As
lators to open within 23 msec fires frequently cause power interruption, discuss further safe-
- at 10 msec intervals, guards with the local fire protection specialist.
beginning on one side
of the Class A • This detector does not sense fires in areas where smoke or
circuit nearest the loop heat cannot reach the detector. Smoke or heat from fires in
controller, the isolators walls, roofs, or on the opposite side of closed doors may not
close to provide the reach the detector.
next isolator down the
line with power Term Description • Photoelectric detectors have a wide range of sensing capabili-
1 Not Used ties, and are best suited for detecting slow, smoldering fires.
- when the isolator next 2 DATA IN/OUT (+)
3 DATA IN (-) The heat sensor in this device provides a source of supplemen-
to the short closes, it reopens within 10 4 Not Used tal information. The heat sensor by itself does not provide life
msec. 5 Not Used
6 DATA OUT (-) safety protection.
The process repeats beginning on the 7 Not Used
other side of the loop controller. • In Canada, install according to the CAN/ULC-S524 Standard
for the Installation of Fire Alarm Systems, the CSA C22.1 Cana-
dian Electrical Code, and the local authority having jurisdiction.
Relay Detector Base, SIGA-RB, SIGA-RB4 • Upon completion of the original installation and following any
This base includes a relay. Nor- modifications or additions to the system, perform a calibrated
mally Open or Normally Closed sensitivity test per NFPA code. Signature Series devices can
operation is selected during in- perform this test and the panel can generate a system sensitiv-
stallation. The dry contact is rated ity report.
for 1 amp (pilot duty) @ 30 Vdc.
The relay’s position is supervised
to avoid accidentally jarring it out
of position. The SIGA-RB can be
operated as a control relay if pro-
grammed to do so at the control
panel. The relay base does not
Term Description
support the SIGA-LED Remote 1 Normally Open
LED. CONTACT RATING 2 DATA IN/OUT (+)
1.0 Amp @ 30 VDC 3 Common
(Pilot Duty) 4 DATA IN (-)
5 Not Used
6 Normally-Closed
7 DATA OUT (-)
Contact us...
Email: [email protected]
Web: Edwards-fire.com
Specifications
Operating voltage 15.20 to 19.95 VDC
Normal operating current 32 µA
Alarm current 32 µA
Vibration level 10 to 35 Hz, with an amplitude of 0.01 in.
Smoke Sensitivity Range UL/ULC: 0.53 to 3.94 %/ft. (1.7 to 12.35 %/m) obscuration
Rate-of-rise rating 15°F/min (8°C/min)
Fixed temperature rating 135°F (57.2°C). Actual alarm point 129 to 141°F (53.9 to 60.6°C).
Air velocity 0 to 4,000 ft./min (0 to 20.32 m/s)
Wall mounting 12 in. (305 mm) max. from ceiling
Spacing, heat detectors Max. 50 ft. (15.2 m) centers
Compatible bases See Ordering Information
Compatible detector testers Testifire 1000, Testifire 2000
Operating environment 32 to 100°F (0 to 38°C), 0 to 93% RH, noncondensing
Construction High Impact Engineering Polymer, White
Storage temperature -4 to 140°F (-20 to 60°C)
Environmental compensation Automatic
Agency Listings CAN/ULC-S529, CAN/ULC-S530, UL 268, UL 268A, UL 521
Ordering Information
Catalog Ship Wt.
Description
Number lbs (kg)
SIGA-PHD Intelligent Multisensor Smoke and Heat Detector 0.4 (0.16)
Compatible Bases
SIGA-SB Detector Mounting Base - Standard
SIGA-SB4 4-inch Detector Mounting Base c/w Trim Skirt
SIGA-RB Detector Mounting Base w/Relay
SIGA-RB4 4-inch Detector Mounting Base w/Relay, c/w Trim Skirt 0.2 (.09)
SIGA-IB Detector Mounting Base w/Fault Isolator
SIGA-IB4 4-inch Detector Mounting Base w/ Fault Isolator, c/w Trim Skirt
SIGA-LED Remote Alarm LED (not for EN54 applications)
SIGA-AB4G-LF Low Frequency Audible (Sounder) Base for CO and Fire Detectors 0.3 (0.15)
SIGA-AB4GT Audible (Sounder) Base for CO and Fire Detectors 0.3 (0.15)
SIGA-TS4 Trim Skirt (supplied with 4-inch bases) 0.1 (.04)
SIGA-DMP Detector Mounting Plate 3.0 (1.4)
SIGA-RTA Detector Removal Tool
SIGA-VA Detector Cleaning Tool
10-11-16