Digi-Tool - PB-210D Calibration Unit For MCB-200 Digilon - Microwave Barrier

The Digi-Tool PB-210D is a calibration unit used to adjust settings for the MCB-200 Digilon microwave barrier, including: - Distance determination and threshold detection methods - Frequency modulation selection - Setting the minimum and maximum speed limits - Setting the detection range - Adjusting the low and high level thresholds - Tuning the receiving signal level It provides information messages and allows recording memory status before installations and performing new installations for the MCB-200.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
72 views2 pages

Digi-Tool - PB-210D Calibration Unit For MCB-200 Digilon - Microwave Barrier

The Digi-Tool PB-210D is a calibration unit used to adjust settings for the MCB-200 Digilon microwave barrier, including: - Distance determination and threshold detection methods - Frequency modulation selection - Setting the minimum and maximum speed limits - Setting the detection range - Adjusting the low and high level thresholds - Tuning the receiving signal level It provides information messages and allows recording memory status before installations and performing new installations for the MCB-200.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

1.

12 Min speed -Mode of setting the lower limit of speed , found out at crossing of DZ, has three
value variants accompanied by messgaes.
0.1 m/s
0.2 m/s
0.4 m/s

1.13 Max speed - Mode of setting the higher limit of speed found out at crossing of DZ,has three
value variants accompanied by messgaes:
4 m/s
6 m/s
10 m/s

1.14 Dist Contr - Working Range Mode ,There are four variants of the values accompanied by
messgaes: Digi-Tool -PB-210D
10-40 m
30-140 m
120-180 m
150-200 m Calibration unit for
Th e flashing of displayed value shows extreme values of the coming signal (defect of functioning
caused by change of external conditions).
1.15 Level L -Low Level Threshold Setting Mode -There are six variants of the values MCB-200 Digilon -Microwave barrier
accompanied by messgaes:
-1 dB
-2 dB
-3 dB
-4 dB
-5 dB
-6 dB

1.16 Level P -High Level Threshold Setting Mode -There are four variants of the values
accompanied by messgaes:
+1 dB
+2 dB
+3 dB
+4 dB

Note -In Level L and Level P modes in the lowest line of LCD screen for tuning
convenience the following is displayed: a conditional scale , where threshold's value-symbo!#,
signal value -symbol ,breaking up of the small and positive thresholds is signaled by symbol
in the right bottom corner of the LCD screen.

USER MANUAL

P/N 20110601-Y.S

4
The Digi-Tool PB-210D is a special calibration and testing unit designed for setting up the MCB-200 LL -Passing of the Low threshold.
Digilon. PL -Passing of the positive threshold.
The Digi-Tool provides the adjustment of the following signals and parameters: HL -Passing ot the High threshold.
-Informational messages indication 1.9 Method -Distance determine and thresholds detecting method, there are two options,with the
-Distance determine and thresholds detecting method following messages;
-Frequency modulation selection Auto - automatic
-Tuning
Manual - manual
-Setting the speed lower limit
The selection of a variant or value in this mode is carried out by buttons or .
-Setting the speed highest limit
To return from the mode and installation saving mode back or forward-press button P ,the
-Setting the detection range
process of installation saving initiates and indicates by the flashing rectangular segment in the rigth
-Setting threshold low level
botton corner of the LCD.
-Setting threshold high level
Notes-At an automatic variant of distance definition and thresholds detection mode,only control
Conntection:
the established values of these parameters is possible,at manual -you may and should regulate
1.1 Digi-Tool Connection to the MCB-200 Sensor's is carried out through test connector(RJ-11)
all the three mentioned modes.
Iocated inside the receiver unit.
1.10 Mod Freq -Frequency modulation setting -There are two options,accompanied by following
1.2 The Digi-Tool's connections and power suppiles are carried out form the MCB-200
messages;
1.3 Digi-Tool is connected to the MCB-200 processor and enables recording the memory status of
Main -major value:
signals before the installations , and also performs and records new installations.
Control and indications : Altern -additional value:
1.4 The DIGI-TOOL includes three control buttons; Simultaneously with change of MCB-200 Receiver modulation frequency value,it is necessary to
1. P -mode change Transmitter modulation frquency value,by using the jumper "F mod" in the
2. -less Receiver unit.
3. -more Change of modulation freqency is necessary in case that there is more then one system working
1.5 The DIGI-TOOL includes an LCD panel to display the setting mode and testing and setting in the same area in order to prevent influence of neighbor's system transmitter radiation on the
parameters. Sensor' s operation(See the user manual of the MCB-200 Digilon).
Operation and setting up the MCB-200 1.11 Tuning -Tuning Mode -In this mode there is indication of the receiving signal level in decibet
1.6 To test MCB-200 operation ,it is necessary to remove the Receiver top cover and connect the (Tune from 2 up to 70).
Digi-Tool to the on board RJ-11 socket, the massage "MCB" should appear on the LCD screen For convenience ,the signal partially (20 dB) is displayed by a linear scale, initial value of a linea
after the connection. scale during tuning changes automatically .
1.7 In order to set the required mode; In this mode following messgaes can the formed.
-Press button P the inscription Indic appears on the LCD scree -that corresponds to the - Range -overcoming of the signal value the limits of the working range.
first mode -MESSAGE INDICATION. -Flashing of numerical value of the corming signal dispalys extreme values for this signal (defect
-Using buttons or choose the required mode; of functioning caused by change of external conditions.)
-The symbol in left bottom corner of LCD indicates the possibility of entering the chosen mode.
-The second pressing of button P will set the mode.
The maximal duration of the tuning mode is 5 minutes , after this time the Detector automatically
Calibration Modes:
back to operation mode.
1.8 Indic -message indication mode,three are five following messages ;
To enter the Tuning mode again -press button Mode once again.
Pow -Power supply is lower than normal;
In this mode and after leaving it , there is recording of service data in the Receiver processor
A! -Forming or alarm signal.
memory , indicated with the flashing rectangular segment in the right bottom corner of LCD screen